INSTRUCTION MANUAL PM1 TRACKER Make the invisible visible: measure and improve your IAQ Clean air solutions Instruction Manual - PM1 Tracker CONTENT 1.Introduction...........................................................................3 2. Start/Stop of the unit.............................................................4 3. PM 1ndex mode.....................................................................4 4. Realtime mode......................................................................5 5. Monitoring mode....................................................................6 6.Settings.................................................................................6 7. Annex: Battery.......................................................................7 PM1 ARE THE MOST HAZARDOUS FOR HEALTH BECAUSE OF THEIR SIZE • Very fine particles, combustion, nanoparticules, bacteria, virus, small spores BECAUSE THEY CAN PENETRATE DEEP INTO THE HUMAN BODY • Passage into the bloodstream, alveoli and to the brain 2 Camfil - Clean air solutions INDOOR AIR CAN BE 50X MORE UNSAFE THAN OUTDOOR AIR • We breathe 15 kg of air per day • Indoor environment can be 50 times more polluted • We spend 90% of our time indoor • More than 25.000.000 particles with each breath Ver. 4.0 The PM1 Tracker is an Indoor Air Quality (IAQ) measurement device, that can be handheld or connected to a cloud. The nephelometric sensor gives indicative values of particules <1µm (0,5 to 1µm), recognized as the most harmful particles to human health. It also measures Wellness parameters: temperature and relative humidity. Different measurement modes are available: • PM 1ndex: IAQ index developed by Camfil and based on WHO guidelines and 50 years of indoor air measurements. • Realtime: Number of particles and PM1 value (mass) – Temperature – Relative Humidity • Monitoring: this function is not activated yet 1. INTRODUCTION The different PM1 Tracker modes are accessible via the Selection Button on the side of the unit: press once to change between modes or hold the button 2s. to validate the mode of choice. The Selection Button is used to select different modes, validate and select options. In certain modes, an automatic stop of the unit is programmed, for battery savings. In order to preserve battery life, in certain modes the unit will automatically switch off when left idle. Information Panel - Multicolour Screen Nb of particles (0,5 – 1µm) PM1 in µg/m3 T°C Relative Humidity Operations Indicator LED Selection Button Battery charge through USB Camfil - Clean air solutions 3 Instruction Manual - PM1 Tracker 2. START/STOP OF THE UNIT Hold the Selection Button for 2s. to start the PM1 Tracker. The Main Menu appears. Here you are able to select the different modes: PM 1ndex, Realtime and Monitoring (this mode is only available if communications settings are activated), Settings and Power Off of the unit. The PM1 Tracker stops automatically if: • PM 1ndex measurement ends and/or is idle for 20mins • Realtime measurement launched and/or is idle for 10mins • Monitoring mode launched and no battery charge for 2hours. 3. PM 1NDEX MODE The PM 1ndex measurement displays the Indoor Air Quality after 15 minutes of data collection. During this time: • The Operational Indicator LED will blink in yellow • After every minute, an intermediate result is displayed in the Information Panel A gauge at the bottom of the Information Panel indicates the status of the test • Hold the Selection Button to stop the measurement • Press the Selection Button once during the measurement process to display an intermediate result. At the end of the test, the final result is displayed in the Information Panel and the Operational Indicator LED will blink in green. The result is still available for 20 minutes with a short press. 4 Camfil - Clean air solutions Ver. 4.0 • PM 1NDEX DEFINITION The PM 1ndex will give an indication of your Indoor Air Quality and allows you to improve it. With 50 years of experience in the Indoor Air (and data collection) industry and based on WHO* guidelines on PM2,5 (annual mean exposition: 10 µg/m3), Camfil have defined an Air Quality Index which ranges from 1 (Very Good) to 5 (Very bad). PM 1ndex Air Quality PM1 (µg/m3) Typical Environment 5 Very bad > 8.3 Industrial or no ventilation 4 Bad < 8.3 Bad ventilation / filtration or no filtration 3 Standard < 3.9 Standard office 2 Good < 1.6 Good ventilation and filtration 1 Very Good < 0.85 Pure air with air cleaner Sources : • • • Guideline WHO* on PM2.5: 10µg/m3 Ambient Air Particle Mass Size Distribution defined in ISO16890: PM1 represents 70 to 80% of PM2,5 value. Hundreds of measurements in Indoor Environments thanks to Camfil Software: Air Image. Note: Indoor Air Quality varies due to sources/activity/humans, etc. Always keep in mind that Indoor Air Quality varies: PM 1ndex mode will provide a mean value for 15 minutes in order to cut off peaks and erratic values. Don’t touch or move the unit during the PM 1ndex measurement. 4. REALTIME MODE This mode will continuously display different parameters. It will allow you to see the number and mass of PM1 in a particular situation. Temperature and Relative Humidity are also displayed. IAQ measurement: Number of particles (0,5 to 1 µm) and PM1 value in µg/m3 Wellness measurement: Temperature and Relative Humidity • Values of Temperature and Relative Humidity are displayed continuously • Particle counting is displayed every minute (first display after 1 minute) • Hold button to stop measurement • Pressing the Selection Button will allow you to switch from one screen to the other. The measurement will go on for 10 minutes (otherwise the measurement stops) *WHO: World Health Organisation Camfil - Clean air solutions 5 Instruction Manual - PM1 Tracker 5. MONITORING MODE This function is not activated yet. 6. SETTINGS Settings gives access to select: Units and Wireless. 6.1 UNITS This menu allows the choice of temperature unit. Select between Celsius and Fahrenheit. 6.2 WIRELESS This menu allows to activate distant connection for the data processing. This function is not activated yet. ANNEX : BATTERY If the unit is off, press the Selection Button once to check battery status: • If the Operational Indicator LED blinks in green, the PM1 Tracker can be used • If the Operational Indicator LED blinks in red, you must charge the battery Note: if no flash appears, charge the battery On the Information Panel, an indication of the battery charge is displayed. The PM1 Tracker will automatically shut down if the battery is empty. In order to charge the battery, use the micro USB/USB cable provided in the box, plug it into your computer or your phone charger. In case of special charger use, check that the voltage is DC 5V and can deliver more than 500mA. If the battery fails and an alert icon appears at the top of the Information Panel, please contact [email protected] for support. 6 Camfil - Clean air solutions Ver. 4.0 Camfil - Clean air solutions 7 CAMFIL – a global leader in air filters and clean air solutions. Camfil is a global leader in the air filtration industry with more than half a century of experience in developing and manufacturing sustainable clean air solutions that protect people, processes and the environment against harmful airborne particles, gases and emissions. These solutions are used globally to benefit human health, increase performance and reduce energy consumption in a wide range of air filtration applications. Our 26 manufacturing plants, six R&D sites, local sales offices and 3,800 employees provide service and support to our customers around the world. Camfil is headquartered in Stockholm, Sweden. Group sales total more than SEK 6 billion per year. www.camfil.com For further information please contact your nearest Camfil office.
© Copyright 2026 Paperzz