UM Series Ironless Parameter Remarks Symbol Unit Winding type UM3 N UM6 S S N S 3-phase synchronous Ironless, 230Vac rms (300Vdc) N 100 200 300 400 Continuous Force* coils @ 110°C Fc N 29 58 87 116 Maximum Speed** @ 300 V vmax m/s 10 18 10 18 10 17 10 16 mount. sfc. @ 20°C K N/Arms 36.3 19.9 36.3 19.9 36.3 19.9 36.3 19.9 Peak Current Maximum Continuous Current S N /W magnet @ 25°C Ip Arms 2.8 5.0 5.5 10.0 8.3 15.0 11.0 20.0 coils @ 110°C Ic Arms 0.8 1.5 1.6 2.9 2.4 4.4 3.2 5.8 Bemf V/m/s 30 16 30 16 30 16 30 16 Rph Ω 18.5 5.5 9.3 2.8 6.2 1.8 4.6 1.4 Lph mH 6 1.8 3 0.9 2 0.6 1.5 0.4 coils @ 25°C τe ms 0.35 0.35 0.35 0.35 all coils Pc W 47 95 142 190 coils to mount. sfc. Rth °C/W 1.8 0.9 0.6 0.45 up to 63% max. coiltemp. τ th s 36 36 36 36 Back EMF Phase-Phasepeak Resistance per Phase* Electrical Time Constant* Maximum Continuous Power Loss Thermal Resistance Thermal Time Constant* 2 coils @ 25°C coils @ 25°C ex. cable Induction per Phase 24 48 Temperature Cut-off / Sensor Mechanical N Fp Motor Constant Electrical S UM12 magnet @ 25°C Motor Force Constant Thermal N UM9 71 95 UM3 in 150mm magnet yoke shown PTC 1kΩ / NTC Coil Unit Weight ex. cables W kg 0.084 0.162 0.240 0.318 Coil Unit Length ex. cables L mm 78 138 198 258 Motor Attraction Force Fa N 0 0 0 0 Magnet Pitch NN τ mm 30 30 30 30 Cable Mass m kg/m 0.08 0.08 0.08 0.08 Cable Type (Power) length 1 m d mm (AWG) 5.3 (22) Cable Type (Sensor) length 1 m d mm (AWG) 3.2 (26) Approvals Magnet yoke dimensions All specifications ±10% Performance Motortype, max voltage ph-ph Peak Force @ 20°C/s increase Tecnotion | www.tecnotion.com | [email protected] Le (mm) 90 120 M4 bolts 3 4 Mass (kg/m) 150 390 6 13 4.8 Magnet yokes can be butted together. * These values are only applicable when the mounting surface is at 20°C and the motor is driven at maximum continuous current. If these values differ in your application, please check our simulation tool. ©2016 Tecnotion BV - All rights reserved - The contents of this document are subject to change without prior notice. UC UF UM UL UXA UXX 21 Ver. 1.08 ** Actual values depend on bus voltage. Please check the F/v diagram in our simulation tool. COIL UNITS O 3.5 Coil unit 17.5 68 19 O 5.3 Power cable O 3.2 Thermal sensor cable 10 5.55 5.55 10 14.2 4.7 Mounting instructions and flatness or parallelism requirements can be found in the Ironless installation manual. CAD files and 3D models can be downloaded from our website. MAGNET YOKES 55 O 4.5 (for M4 DIN 912) O 7.5 (4 deep) 21 O 3.2 4.4 49 Magnet yoke Hole O3 (2x) For Dowelpin DIN7 O3h8 (Optional use) max 90 UM 90mm 14.5 20 20 3.5 30 UM 3 30 45 max 120 UM 120mm 20 7.5 22.45 66 A Optional: Digital Hall Module 14.5 20 20 20 20 20 20 3.5 20 20 20 20 20 3.5 20 20 20 20 3.5 7.5 30 75 30 UM 6 30 22.45 max 150 126 7.5 30 30 22.45 30 30 30 30 30 105 30 14.5 20 20 20 20 20 20 20 20 20 UM 9 2x UM 150mm M2x3 Slotted Countersunk DIN963 (2x) DETAIL A 30 105 150 186 14.5 7.5 30 Ver. 1.08 22.45 20 20 20 UM 12 UM 390mm max 390 30 30 30 30 30 345 30 30 30 30 30 30 ©2016 Tecnotion BV - All rights reserved - The contents of this document are subject to change without prior notice. 246 UC UF UM UL UXA UXX
© Copyright 2026 Paperzz