the datasheet

Profibus DP Ecofast
L45467-G116-W58
Application
Profibus DP-Desina Hybrid cable for
trailing applications (PUR)
Trailing cable for following
requirements:
- 5 million bending cycles
- bending radius 7.5 x max ø
- acceleration 2.5 m/s2
- 5 million bending cycles
- bending radius 150 mm
- at a speed of 3m/s
- acceleration 9 m/s2
Cable Construction
A) Wire LIH 1.5/2.4
Conductor
Stranded Bare Copper Wire, 84x0.15 (1.5mm2)
Ø 1.55 mm
Insulation
Number printed FRNC, 0.43mm wall thickness
Ø 2.40 mm
Conductor
Stranded Bare Copper Wire, 19x0.14 (0.3mm2)
Ø 0.67 mm
Insulation
Foamed Polyethylene (PE)
Ø 2.56 mm
Colour Code
Red, Green twisted pair, Plastic tape overlapped
Screen
-Longitudinal Alulaminate foil
100% coverage
Shield
-Tinned copper wire braid, 0.15mm
65% coverage
B) Screened pair
Core
Single pair
B) Screened pair
Power cores
A) Wire LIH 1.5/2.4, numbered 1 - 4
Filler
Fillers in gaps
Tape
Plastic tape overlapped
Outer Jacket
Polyurethane (PUR) VT, 1.0mm wall thickness
Electrical Data
see next page
Page1/2
T: 01279 871150 | F: 01279 871129 | www.belcom.co.uk
Ø 11.0 ± 0.3
Electrical Data
Conductor resistance (wire to a)
≤ 14 Ohm/km
Loop resistance (wire to b)
≤ 138 Ohm/km
Screen resistance
≤ 15 Ohm/km
Insulation resistance
≥ 20 MOhm*km
Operating voltage (peak)
300 V
Test voltage (wire/wire/screen rms 50Hz 1min.)
2000 V
Ampacity (up to 25˚C) wire to a)
≤ 12 A
B) Screened pair
3-20 MHz
Characteristic Impedance
31.25 - 38.4 kHz
Attenuation
150 ± 15 Ω
185 ± 18.5 Ω
9.6 kHz
270 ± 27 Ω
16 MHz
≤ 42 dB/km
4 MHz
≤ 22 dB/km
38.4 MHz
≤ 4 dB/km
9.6 MHz
≤ 2.5 dB/km
Capacitance (1KHz)
≈ 30 nF/km
Surface transfer impedance
20 MHz
Rel. Velocity of propagation
≤ 60 mΩ/m
≈ 81 %
Mechanical & Thermal Characteristics
Conductor material
acc. to DIN EN 13602 Cu-ETP1-A...
Screen material
acc. to DIN EN 13602 Cu-ETP-A...-B
Insulating material
acc. to DIN EN 50290-2-23 (VDE 0819), table 2/A (HD 624.3)
Insulating material
acc. to DIN EN 50290-2-26 (VDE 0819) (HD 624.6)
Jacket material
acc. to F45052-F5100 (similar to DIN VDE 0282)
Flame test
acc. to IEC 60332-1-2
Sunlight resistant
acc. to UL 1581 Sec.1200
Pulling force with
≤ 300 N
Permissable Temp. range:
-40˚C up to +60˚C
Min. bending diameter allowed:
single 7 x Ø
Weight about
150 kg/km