9146 ELKAY 376B-1 PIRTIMER INSTRUCTIONS_Layout 1

9146 ELKAY 376B-1 PIRTIMER INSTRUCTIONS_Layout 1 14/04/2010 09:50 Page 1
pirtimer
energybasic
pirtimer fitting and operating instructions
pirtimer - two wire
Product: 376B-1 Two wire
Rating at 240V ac
• Incandescent 10A • Compact Fluorescent 10A
• Resistive
10A • Fluorescent 10A • Time Delay 2min - 1h
1.
2.
3.
4.
5.
6.
7.
8.
9.
Prior to fitting identify the Live In and Switch Live wires. Ensure if fitting into
metal back boxes lugs are removed that are not being used.
Set the dip switches to the required time settings (See Diagram 3).
Switch the Dip switch Number 4 to the ON position and wait 10 seconds for
a red neon to begin flashing adjacent to the PIR dome, behind the face plate.
Fit the Live In and Switch Live into the terminals as marked (Turn anticlockwise).
Rotate lux level adjustment to the + for initialisation.
Turn on the mains power, the lights will come on and the unit will flash for
approximately 4 minutes before turning off your lights (N.B. As long as no
movement is detected).
Adjust lux level to the desired setting. Please note the PIR should be carefully
adjusted when considering ambient light levels.
The product will turn itself off once the required time has elapsed and there is
LIVE IN
no longer any movement detected.
NEUTRAL
Please ensure device is screwed back to the backbox once installation is complete.
NOTE: 2 Wire devices not be used with contactors. Capacitor
may be required when switching compact fluorescent or
very low power lighting. For example: LIVE
2D fittings,
energy saving
IN
NEUTRAL
lamps, LED’s or any low power consuming
loads.
OUT
7 LIVE
metres
OUT
7 LIVE
metres
Diagram
2
Diagram 1
Diagram 4
Wiring diagram for two wire additional
Switches/PIR into circuit.
Wiring diagram for a
two wire unit.
PIR timer sensor detection diagram.
N SL L
LIVE IN
NEUTRAL
LIVE OUT
LIVE OUT
4 - 6m
LIVE IN
NEUTRAL
N SL L
N SL L
N SL L
N SL L
5 - 7m
plan view
N SL L
3 - 4m
Diagram 3
Please note that the black bar denotes the position of the dip switch.
2 mins
5 mins
2.
1.
10 mins
2.
1.
20 mins
4.
3.
2.
1.
40 mins
4.
DIP
3.
DIP
4.
DIP
3.
3.
ON
1.
4.
ON
2.
DIP
3.
ON
1.
4.
ON
ON
2.
DIP
3.
ON
DIP
4.
2.
5 - 7m
1.
side view
60 mins
IMPORTANT NOTICE
All wiring should be carried out by a competent person or a qualified electrician and should be fitted to IEE 17th Edition Wiring regulations BS7671:2008.
Call +44 (0) 1675 468222 or click www.elkay.co.uk