City of Surrey PLANNING & DEVELOPMENT REPORT File: 7908-0137-00 Planning Report Date: March 9, 2009 PROPOSAL: • Rezone from RF and RM-D to RF • Development Variance Permit in order to allow subdivision into 5 RF lots. DVP to reduce the minimum front yard setback of the RF Zone for all proposed lots. LOCATION: 11871, 11873, 11885 and 11887 River Road OWNER: Sumitter Singh Pattar ZONING: RM-D and RF OCP DESIGNATION: Urban Staff Report to Council File: Planning & Development Report 7908-0137-00 Page 2 RECOMMENDATION SUMMARY • By-law Introduction and set date for Public Hearing for Rezoning. • Approval for Development Variance Permit to proceed to Public Notification. DEVIATION FROM PLANS, POLICIES OR REGULATIONS • Seeking reduced front yard setback in the RF Zone, from 7.5 metres (25 ft.) to 5.5 metres (18 ft.). RATIONALE OF RECOMMENDATION • Complies with OCP Designation. • Due to the parallelogram shape of the proposed lots, under the current front yard setback requirements of the RF Zone, new homes built on the proposed lots will appear to be setback further compared to homes built on a more conventional rectangular shaped lot. Therefore, the requested variance will bring the homes closer to the street which will create an aesthetic that is more compatible with existing front yard setbacks of the RF-zoned lots further to the west of the subject site, along River Road. • The proposed setbacks achieve a more urban and pedestrian-oriented streetscape. Planning & Development Report Staff Report to Council File: 7908-0137-00 Page 3 RECOMMENDATION The Planning & Development Department recommends that: 1. By-law be introduced to rezone the subject site from "Single Family Residential Zone (RF)" and "Duplex Residential Zone (RM-D)" (By-law No. 12000) to "Single Family Residential Zone (RF)" (By-law No. 12000) and a date be set for Public Hearing. 2. Council approve Development Variance Permit No. 7908-0137-00, (Appendix VI) varying the following, to proceed to Public Notification: (a) 3. to reduce the minimum front yard setback of the RF Zone from 7.5 metres (25 ft.) to 5.5 metres (18 ft.) for proposed Lots 1 to 5. Council instruct staff to resolve the following issues prior to final adoption: (a) ensure that all engineering requirements and issues including restrictive covenants, and rights-of-way where necessary, are addressed to the satisfaction of the General Manager, Engineering; (b) submission of a subdivision layout to the satisfaction of the Approving Officer; (c) demolition of existing buildings and structures to the satisfaction of the Planning and Development Department; (d) submission of an acceptable tree survey and a statement regarding tree preservation; (e) removal of unauthorized truck parking to the satisfaction of the Planning and Development Department; and (f) installation of a 15-metre (50 ft.) wide landscaping buffer, as proposed by the same applicant for the now closed application No. 7904-0135-00, on the lot to the north. REFERRALS Engineering: The Engineering Department has no objection to the project subject to the completion of Engineering servicing requirements as outlined in Appendix III. School District: Projected number of students from this development: 2 Elementary students at Prince Charles Elementary School 1 Secondary student at L.A. Matheson Secondary School Parks, Recreation & Culture: The applicant should provide cash-in-lieu of parkland. There are no other concerns with the application. Planning & Development Report Staff Report to Council File: 7908-0137-00 Page 4 Greater Vancouver Sewerage and Drainage District (GVS & DD): On this application, GVS&DD comments are outstanding. Any conditions imposed by the GVS&DD will be a condition of final adoption. SITE CHARACTERISTICS Existing Land Use: One single family RF lot with a non-conforming duplex and one vacant lot, a portion of which is being used for truck parking that is partially zoned RM-D and partially zoned RF. Adjacent Area: Direction Existing Use North: South (Across River Road): Non-conforming truck park (application No. 7904-0135-00 for TUP for truck parking was closed due to inactivity) . Single family lots with new houses under construction. Townhouses and park. West: Duplex. East: OCP/NCP Designation Industrial/Business Park in the South Westminster NCP Existing Zone Urban RF Urban RM-15 and RF Urban RM-D IB-2 DEVELOPMENT CONSIDERATIONS • The subject site consists of two lots and is located on the west side of River Road just outside of the South Westminster Neighbourhood Concept Plan (NCP) area. The site is designated Urban in the Official Community Plan (OCP). The subject site is currently split-zoned "Single Family Residential Zone (RF)" and "Duplex Residential Zone (RM-D)". • This application proposes rezoning a portion of the split-zoned subject site at 11871/73 River Road, from "Single Family Residential Zone (RF)" and "Duplex Residential Zone (RM-D)" to "Single Family Residential Zone (RF)" to permit five single family lots with the neighbouring RF-zoned property at 11885/11887 River Road and a Development Variance Permit to reduce the minimum front yard setback of the 5 proposed lots from 7.5 metres (25 ft.) to 5.5 metres (18 ft.). • In 1999, development application No. 7999-0214-00 was submitted for the subject site. This application proposed subdividing to create four residential lots. Of these four lots, one was proposed to retain the existing duplex. The application did not proceed and the application was subsequently closed. Staff Report to Council File: Planning & Development Report 7908-0137-00 Page 5 • The proposed lots meet the area and dimension requirements of the RF Zone. • Each of the proposed lots has 17.8 metres (58.4 ft.) of street frontage. However, given that the shape of the lots is a parallelogram, the effective width (measured perpendicular to the side lot line) is only 13.45 metres (44.1 ft.). This still provides sufficient width to build a reasonably sized home. The average depth of the proposed lots is approximately 50 metres (164 ft.), which provides for adequate rear yard space. • Just to the east, there are four single family residential lots that were created under development application No. 7901-0267-00. Of these four lots, two of them are currently under construction with new homes being built. • Views of the Pattullo Bridge, New Westminster, and the Cascade Mountains are evident from the subject site. • Currently, the existing unauthorized truck parking use on the neighbouring lot to the north (at 10198 Grace Road) encroaches into the subject site. The owner of the subject site is the same owner of the abutting industrial lot. The applicant will be required to remove the truck parking on the subject as a condition of rezoning and subdivision approval. In addition, installation of a 15-metre (50 ft.) wide landscape buffer along the shared property line with the applicant's industrial lot to the north (10198 Grace Road) will be required to provide an improved interface for the future residents on the proposed RF lots. • A Greater Vancouver Sewerage and Drainage District (GVS & DD) statutory right-of-way for drainage runs through the very rear portion of the proposed lots. Any requirements of GVS&DD will be addressed before consideration of final adoption. Neighbourhood Character study and Building Scheme • Tynan Consulting Ltd. prepared the Neighbourhood Character Study and Building Scheme. The Character Study involved reviewing a number of existing homes in the neighbourhood in order to establish suitable design guidelines for the proposed subdivision. A summary of the Design Guidelines is attached. • In order to reflect the established character of the newer homes within the neighbourhood, the design consultant recommends that two specific styles of homes be permitted, including "NeoTraditional" and "Neo-Heritage." • Basement-entry homes and secondary suites will not be permitted. Lot Grading • Preliminary lot grading plans were prepared by Aplin & Martin Consultants Ltd. The plans were reviewed by staff and found acceptable. • The subject site is subject to an initial considerable slope of about 30%, but this levels off about 8m (26 ft.) away from River Road. • Given the depth of the existing servicing, in-ground basements can be achieved. Planning & Development Report Staff Report to Council File: 7908-0137-00 Page 6 Tree Survey and Preservation Plan • Max Rathburn of Arbortech Consulting Ltd. prepared the Arborist Report and Tree Preservation/Replacement Plans. They have been reviewed by City staff and deemed acceptable. • The chart below provides a summary of the tree retention and removal by species: Tree Species Western redcedar Bigleaf maple Deodar cedar Sawara Cypress Bitter Cherry Total Total No. of Trees 2 4 2 1 1 10 Total Proposed for Retention 1 0 0 0 0 1 Total Proposed for Removal 1 4 2 1 1 9 • All 9 trees proposed for removal are either hazardous or are located within, or near the building envelope. • The report indicates 18 replacement trees are required and 18 replacement trees are proposed. PRE-NOTIFICATION Pre-notification letters were sent on June 9, 2008 and staff received no responses. BY-LAW VARIANCE AND JUSTIFICATION (a) Requested Variance: • To reduce the minimum front yard setback of the RF Zone from 7.5 metres (25 ft.) to 5.5 metres (18 ft.) for proposed Lots 1 to 5. Applicant's Reasons: • Due to the initial steep slope of the property, a home that is built closer to the street will be better suited to fit the topography of the site. Staff Comments: • In order to take advantage of the parallelogram shape of the proposed lots, and to enhance the streetscape, the Building Scheme specifies that the garages must be set back from the entrance veranda or the front wall face of the principal building, by a minimum of 4.0 metres (13.1 ft.). This will give the appearance that the streetscape is less dominated by garages. Planning & Development Report Staff Report to Council File: 7908-0137-00 Page 7 • Given that the RF Zone permits a front yard setback relaxation at a lower floor to 5.5 metres (18 ft.) for a maximum of 50% of the length of the front of the dwelling (excluding the garage), the proposed variance is only a slight deviation from what is allowed in the RF Zone. • Staff support the proposed variance. INFORMATION ATTACHED TO THIS REPORT The following information is attached to this Report: Appendix I. Appendix II. Appendix III. Appendix IV. Appendix V. Appendix VI. Appendix VII. Appendix VIII. Lot Owners, Action Summary and Project Data Sheets and Survey Plan Proposed Subdivision Layout Engineering Summary Building Design Guidelines Summary Summary of Tree Survey and Tree Preservation Contour Map and 200 Year Floodplain Landscape Buffer Originally Proposed for Application No. 7904-0135-00 Development Variance Permit No. 7908-0137-00 Jean Lamontagne General Manager Planning and Development JD/kms v:\planning\plncom09\02031505jd.doc SEH 6/24/10 3:16 PM Page 1 APPENDIX I Information for City Clerk Legal Description and Owners of all lots that form part of the application: 1. (a) Agent: Name: Address: Tel: 2. 3. Eric Aderneck, Aplin & Martin Consulting Ltd. 12448 - 82 Avenue, Suite 201 Surrey, BC V3W 3E9 604-572-5402 Properties involved in the Application (a) Civic Addresses: 11885, 11887, 11871 and 11873 River Road (b) Civic Address: 11885/11887 River Road Owner: Sumitter Singh Pattar PID: 023-645-725 Lot 3 Section 25 Block 5 North Range 3 West New Westminster District Plan 31340 (c) Civic Address: 11871/11873 River Road Owner: Sumitter Singh Pattar PID: 023-645-717 Lot 2 Section 25 Block 5 North Range 3 West New Westminster District Plan LMP31340 Summary of Actions for City Clerk's Office (a) Introduce a By-law to rezone a portion of the site. (b) Proceed with Public Notification for Development Variance Permit No. 7908-0137-00. v:\planning\plncom09\02031505jd.doc SEH 6/24/10 3:16 PM Page 2 SUBDIVISION DATA SHEET Proposed Zoning: RF Requires Project Data GROSS SITE AREA Acres Hectares NUMBER OF LOTS Existing Proposed Proposed .84 ac .34 ha 2 5 SIZE OF LOTS Range of lot widths (metres) Range of lot areas (square metres) 17.8 m 630 - 735 m² DENSITY Lots/Hectare & Lots/Acre (Gross) Lots/Hectare & Lots/Acre (Net) 14.7 uph/5.9upa 14.7 uph/5.9 upa SITE COVERAGE (in % of gross site area) Maximum Coverage of Principal & Accessory Building Estimated Road, Lane & Driveway Coverage Total Site Coverage PARKLAND Area (square metres) % of Gross Site 40% 5% 45% n/a Required PARKLAND 5% money in lieu YES TREE SURVEY/ASSESSMENT YES MODEL BUILDING SCHEME YES HERITAGE SITE Retention NO BOUNDARY HEALTH Approval NO DEV. VARIANCE PERMIT required Road Length/Standards Works and Services Building Retention Others NO NO NO YES v:\planning\plncom09\02031505jd.doc SEH 6/24/10 3:16 PM
© Copyright 2026 Paperzz