UM 30 Ultrasonic sensor Dimensional drawing Operating scanning range 30 . . . 1300 mm 127.5 Ultrasonic sensor 73.5 1 M 30x1.5 High measurement accuracy thanks to time-of-flight measurement Independent of material shape (including films, glass and bottles) Teach-in Insensitive to dirt, dust and fog Operating scanning range up to 1,300 mm Binary outputs or analog output 2 3 5 Adjustments possible All types 5 1 Fastening nuts, width across 36 mm 2 Connection plug M 12 3 Control and display panel 4 Setting key 2 5 Setting key 1 6 2 7 1 3 P2 D2 D1 P1 4 5 6 Accessories 7 Connection types UM 30-11111 UM 30-12111 UM 30-13111 UM 30-11112 UM 30-12112 UM 30-13112 UM 30-11113 UM 30-12113 UM 30-13113 5-pin, M 12 5-pin, M 12 5-pin, M 12 Mounting systems 8 SENSICK brn 1 blk 4 blu 3 wht 2 gra 5 brn 1 blk 4 blu 3 wht 2 gra 5 L+ Q, Q M NC NC © SICK AG · Industrial Sensors · Germany · All rights reserved L+ Q2 , Q2 M Q1, Q 1 NC brn 1 blk 4 blu 3 wht 2 gra 5 L+ NC M QA NC 8 010 312/12-03-03 UM 30 Technical data UM 30- Operating scanning range (limiting scanning range) Weight Housing material 30 ... 250 mm (350) 60 ... 350 mm (600) 200 ... 1300 mm (2000) 320 kHz 400 kHz 200 kHz 0.36 mm ± 0.15 % of final value ≤ 2 % of final value 12 ... 30 V DC 1) ± 10 % ≤ 70 mA Q: PNP, VS –2 V, Imax = 500 mA Q1, Q2: PNP, VS –2 V, Imax = 500 mA QA: 4 ... 20 mA/0 ... 10 V 50 ms 70 ms 110 ms 11/s 8/s 6/s 20 mm 5 mm 2.5 mm 2s Plug M 12, 5-pin IP 65 Operation –20 °C ... +70 °C Storage –40 °C ... +85 °C 260 g Nickel-plated brass 1) 4) Ultrasonic frequency Resolution Reproducibility Accuracy Supply voltage VS Ripple Current consumption 2) Switching outputs, reversible3) Analog output, reversible3) 4) Response time5) Switching frequency Switching hysteresis Standby delay Connection type Enclosure rating Ambient temperature 6) 2) 3) Limit values Without load Outputs short-circuit protected Automatic switching between voltage and current outputs dependent on load 11111 11112 11113 12111 12112 12113 13111 13112 13113 5) Current output 4 ... 20 mA: RL ≤ 500 Ω, VS ≥ 20 V; RL ≤ 100 Ω, VS ≥ 12 V Voltage output 0 ... 10 V: RL ≥ 100 kΩ; VS > 15 V 6) Detection ranges 100 50 0 Only with UM 30-_ _ _ _3: Recovery time 32 ms according to EMC EN 50 319 Temperature compensation at –20 ... +50 °C Order information 50 100 200 100 0 100 200 [mm] 800 50 2 [mm] 400 3 800 1 150 1 1200 300 200 400 250 500 5 1600 5 2000 600 2400 350 700 2800 400 800 3200 1 Aligned plate 500 x 500 mm 2 Pipe diameter 10 mm 3 Pipe diameter 27 mm Part no. 6 025 655 6 025 656 6 025 657 6 025 660 6 025 661 6 025 662 6 025 665 6 025 666 6 025 667 4 4 8 010 312/12-03-03 800 200 1 5 400 UM 30-1311_ 1300 mm 3 300 0 100 100 4 400 [mm] UM 30-1211_ 350 mm UM 30-1111_ 250 mm Type UM 30-11111 UM 30-12111 UM 30-13111 UM 30-11112 UM 30-12112 UM 30-13112 UM 30-11113 UM 30-12113 UM 30-13113 4 Operating scanning range 5 Limiting scanning range © SICK AG · Industrial Sensors · Germany · All rights reserved SENSICK 9
© Copyright 2026 Paperzz