CFL-UHV-F1 CIRCULAR FILM LINED ULTRA HIGH VELOCITY SILENCER (<7000 FPM) HOW TO SPECIFY: EXAMPLE CERTIFIED PERFORMANCE DATA 24 X CFL-UHV-F1 X 72 Silencer Duct Connection Model Size Insertion Loss (IL) + : “forward flow” where noise & airflow move in same direction (e.g. supply side) - : “reverse flow” where noise & airflow move in opposite directions (e.g. return side) DC (in.) SL (in.) 12 24 24 48 36 72 48 96 60 120 FACE VEL. OCTAVE BAND - Hz/D.I.L. (dB) 125 250 500 1000 2000 4000 8000 (ft. per min.) 63 - 6000 3 4 9 1 3 - 6000 6 9 12 7 9 12 9 12 12 13 16 13 + 6000 0 1 0 4 8 - 6000 7 10 + 6000 4 8 + 6000 0 3 6 - 6000 9 + 6000 6 0 - 6000 0 + 6000 7 9 7 6 7 11 0 5 11 14 11 12 10 10 10 6 8 13 13 12 14 7 11 13 9 10 4 10 3 13 7 6 15 15 14 17 12 8 13 12 12 11 12 14 10 13 10 9 10 9 5 7 5 8 10 5 7 9 4 6 8 9 5 6 7 2 9 5 8 6 7 8 5 6 7 4 5 8 7 6 3 6 3 DC (in.) SL (in.) 12 36 24 1 3 72 36 4 1 2 3 1 2 3 108 48 144 60 180 Silencer Length DC - Duct Connection Size (inches) SL - Silencer Length (inches) FACE VEL. OCTAVE BAND - Hz/D.I.L. (dB) 125 250 500 1000 2000 4000 8000 (ft. per min.) 63 - 6000 4 + 6000 1 0 - 6000 0 + 6000 3 4 3 7 12 4 9 6 10 - 6000 10 + 6000 7 0 10 + 6000 7 15 16 13 19 21 19 17 15 7 16 9 10 4 17 21 11 12 17 23 19 7 14 19 16 10 11 18 22 13 8 9 16 11 20 + 6000 9 17 18 21 24 20 19 17 17 14 11 14 9 6 12 9 13 8 10 12 7 9 7 11 See pages 4.1 - 4.25 for selection information. DIL above 50dB may be limited due to noise flanking around the silencer or along the duct walls. If more than 50dB DIL is required, contact your local Vibro-Acoustics Representative or call 1-800-565-8401. Pressure Drop (PD) DUCT SILENCER SILENCER CONNECT. OUTER LENGTH WEIGHT SIZE (in.) DIA. (in.) (in.) (lbs) 12 12 24 24 36 36 48 48 28 28 40 40 52 52 64 64 60 76 60 76 24 36 48 72 72 108 96 144 114 149 307 414 584 810 965 1340 180 1985 120 1418 FACE VELOCITY (feet per minute) / Pressure Drop (in.w.g.) 2000 0.01 0.02 0.01 0.01 0.01 0.01 0.01 0.01 0.01 0.01 3000 0.03 0.04 0.02 0.03 0.02 0.03 0.02 0.03 4000 0.02 0.03 0.04 0.07 0.04 0.06 0.03 0.05 0.03 0.05 0.03 0.04 5000 0.07 0.11 0.06 0.09 0.05 0.08 0.05 0.08 0.05 0.07 6000 0.10 0.15 0.08 0.13 0.08 0.12 0.07 0.11 0.07 0.10 7000 0.14 0.21 0.11 0.18 0.10 0.16 0.10 0.15 0.09 0.14 Pressure drops are reported in accordance with ASTM E477 methods and are based upon IDEAL flow conditions (5 diameters of straight duct on silencer inlet and 10 on outlet). Less than ideal conditions will result in an increase in pressure drop due to System Effects. See Silencer System Effects Data on page 4.19. Generated Noise (GN) @ 3 sq.ft. face area LENGTH FACE VELOCITY (inches) (feet per minute) ALL - 7000 - 5000 + 5000 + 7000 GN correction chart at right must be used to correct GN to other face areas. OCTAVE BAND - Hz/GENERATED NOISE (dB re 10 -12 watts) 63 125 250 500 1000 2000 4000 84 74 73 83 76 66 65 75 FACE AREA (sq.ft.) Questions? 1-800-565-8401 dB We reserve the right to improve our designs and data at any time without notice. 75 65 65 75 1.5 -3 81 71 70 80 3 0 5.161 78 68 65 75 6 +3 77 67 64 74 12 +6 66 56 54 64 24 +9 6 19 18 21 14 17 19 14 10 9 17 16 14 19 - 6000 0 11 18 13 9 12 13 16 9 - 6000 0 5 8000 0.18 0.27 0.15 0.23 0.13 0.20 0.13 0.19 16 11 12 9 10 11 7 8 9 5 7 3 5 6 3 4 9 5 8 3 7 9 1 4 : Acceptable (0 - 0.35”) : Caution (>0.35”) Pressure Drop may be too high for certain applications 0.12 0.18 8000 67 57 55 65 48 +12 Copyright © 2010 Vibro-Acoustics CFL-UHV-F1 CFL-UHV-F2 CIRCULAR FILM LINED ULTRA HIGH VELOCITY SILENCER (<7000 FPM) HOW TO SPECIFY: EXAMPLE CERTIFIED PERFORMANCE DATA 24 X CFL-UHV-F2 X 72 Duct Silencer Connection Model Size Insertion Loss (IL) + : “forward flow” where noise & airflow move in same direction (e.g. supply side) - : “reverse flow” where noise & airflow move in opposite directions (e.g. return side) DC (in.) SL (in.) 12 24 24 48 36 72 48 96 60 120 FACE VEL. OCTAVE BAND - Hz/D.I.L. (dB) 125 250 500 1000 2000 4000 8000 (ft. per min.) 63 - 6000 0 2 1 3 2 + 6000 0 1 0 3 5 - 6000 + 6000 - 6000 0 3 2 4 3 6 8 9 9 + 6000 3 7 0 4 8 3 14 10 13 15 10 6 8 8 6 7 14 3 10 13 14 12 8 13 12 11 11 12 13 12 13 10 9 7 9 7 9 5 2 3 5 5 6 1 9 8 4 7 3 11 10 12 12 5 15 10 3 4 5 1 12 7 6 8 7 3 11 13 7 9 8 9 4 + 6000 9 6 0 5 8 12 5 - 6000 5 7 3 5 11 11 4 + 6000 - 6000 8 6 10 9 4 7 5 4 6 8 6 5 6 7 6 DC (in.) SL (in.) 12 36 24 72 36 1 2 108 48 3 2 144 60 180 Silencer Length DC - Duct Connection Size (inches) SL - Silencer Length (inches) FACE VEL. OCTAVE BAND - Hz/D.I.L. (dB) 125 250 500 1000 2000 4000 8000 (ft. per min.) 63 - 6000 0 + 6000 - 6000 3 3 11 1 2 2 4 0 3 - 6000 6 + 6000 3 8 7 3 6 10 0 5 10 - 6000 6 11 + 6000 4 0 5 - 6000 7 + 6000 0 + 6000 9 10 4 10 13 6 12 5 11 16 16 8 13 19 13 19 17 9 15 14 21 17 16 12 18 19 17 18 12 20 19 7 18 15 18 17 21 19 18 19 17 11 17 17 19 21 9 11 13 8 10 DUCT SILENCER SILENCER CONNECT. OUTER LENGTH WEIGHT SIZE (in.) DIA. (in.) (in.) (lbs) 12 12 24 24 36 36 48 48 20 20 32 32 44 44 56 56 60 68 60 68 24 36 48 72 72 108 96 144 76 99 228 305 456 618 766 1047 120 1135 180 1589 0.01 0.02 0.01 0.01 0.01 0.01 0.01 0.01 0.01 0.01 3000 0.03 0.04 0.02 0.03 0.02 0.03 0.02 0.03 4000 0.02 0.03 0.04 0.07 0.04 0.06 0.03 0.05 0.03 0.05 0.03 0.04 5000 0.07 0.11 0.06 0.09 0.05 0.08 0.05 0.08 0.05 0.07 6000 0.10 0.15 0.08 0.13 0.08 0.12 0.07 0.11 0.07 0.10 Pressure drops are reported in accordance with ASTM E477 methods and are based upon IDEAL flow conditions (5 diameters of straight duct on silencer inlet and 10 on outlet). Less than ideal conditions will result in an increase in pressure drop due to System Effects. See Silencer System Effects Data on page 4.19. Generated Noise (GN) @ 3 sq.ft. face area LENGTH FACE VELOCITY (inches) (feet per minute) ALL - 7000 - 5000 + 5000 + 7000 GN correction chart at right must be used to correct GN to other face areas. OCTAVE BAND - Hz/GENERATED NOISE (dB re 10 -12 watts) 63 125 250 500 1000 2000 4000 84 74 73 83 76 66 65 75 FACE AREA (sq.ft.) Questions? 1-800-565-8401 dB We reserve the right to improve our designs and data at any time without notice. 75 65 65 75 1.5 -3 81 71 70 80 3 0 5.162 78 68 65 75 6 +3 77 67 64 74 12 +6 66 56 54 64 24 +9 6 10 7 11 9 9 0.09 3 7 8 0.14 9 12 8 13 0.14 0.21 0.11 0.18 0.10 0.16 0.10 0.15 5 10 9 7 11 7000 11 9 6 9 FACE VELOCITY (feet per minute) / Pressure Drop (in.w.g.) 2000 9 11 See pages 4.1 - 4.25 for selection information. DIL above 50dB may be limited due to noise flanking around the silencer or along the duct walls. If more than 50dB DIL is required, contact your local Vibro-Acoustics Representative or call 1-800-565-8401. Pressure Drop (PD) 16 12 10 12 6 14 16 14 14 15 8000 0.18 0.27 0.15 0.23 0.13 0.20 0.13 0.19 7 9 8 7 4 7 5 3 4 5 1 3 4 : Acceptable (0 - 0.35”) : Caution (>0.35”) Pressure Drop may be too high for certain applications 0.12 0.18 8000 67 57 55 65 48 +12 Copyright © 2010 Vibro-Acoustics CFL-UHV-F2
© Copyright 2026 Paperzz