Developing Safety Guidelines for Highly Flammable/ Flammables stored in large quantities Purpose: Develop a reference document that can be used by a Principle Investigator or a designee to assist in the development of Safety Operating Procedures (SOP) for Highly Flammable/Flammables stored in large quantities. The following elements below should be included when developing safety guidelines for Highly Flammable/Halogenated Solvents/Flammables stored in large quantities: A. Hazard Summary These guidelines are intended to provide general guidance on how to work safely with Highly Flammable/Halogenated Solvents and Bulk Flammable Storage. Highly flammable chemicals are chemicals that have a National Fire Protection Agency (NFPA) rating of 3 or higher for flammability: NFPA 4: Extremely flammable chemical with a flash point below 73 F (22.8 C) NFPA 3: Serious flammable chemical with a flash point at or above 73 F (22.8 C) but less than 100 F (37.8 C). And has one or more of the following characteristics: Vaporizes readily and can be ignited under almost all ambient conditions. May form explosive mixtures with or burn rapidly in air. May burn rapidly due to self-contained oxygen. May ignite spontaneously in air Examples include: Acetonitrile, Ethyl Ether, Methanol, Propanol, Benzene, Carbon Tetroxide, ethyl bromide, tert-butyl lithium, Acetone and toluene. Flammable Gas Cylinders - Flammable gases are any material which is a gas at 20°C (68°F) or less at an absolute pressure of 14.7 psi which is ignitable at an absolute pressure of 14.7 psi when in a mixture of 13% or less by volume with air; or has a flammable range at an absolute pressure of 14.7 psi with air of at least 12% regardless of lower limit. Pyrophoric gases have an auto ignition temperature in air at or below 54°4 C (130°F). Examples are hydrogen gas, acetylene, butane, ethylene, methylamine, vinyl chloride, and silane. B. Special Handling Procedures and Storage Requirements Handling processes should be designed to minimize the potential for splash, splatter, or other likely scenarios for accidental contact. The handling of these materials needs to be conducted in a fume hood. If the process does not permit the handling of such materials in a fume hood, the lab personnel should contact Environmental Health and Safety at x44036 for review the adequacy of ventilation measures. Bulking control hazards: When transferring flammable liquid from a bulk container (greater than 5 gallons), the container must be electrically bonded and grounded. Transfer flammable liquids from containers of five gallon capacity or less inside a laboratory hood or other area with similar ventilation to prevent accumulation of flammable concentration of vapors. Additionally: The handling of these materials needs to be used in a fume hood. NFPA regulations state that dispensing of extremely flammable liquids to or from containers less than or equal to 20L (5gal) in capacity shall be performed in a fume hood, or area with adequate ventilation, or a liquid storage area specifically designed and protected for dispensing flammable liquids. Avoid static electricity or hot surfaces for highly flammable chemicals; this can serve as an ignition source. A safety shower and eyewash must be available and accessible when working with these chemicals. Per NFPA regulations: Lecture bottle-sized cylinders of all gases with a health hazard rating of 3 or 4, or a 2 without physiological warning properties, or pyrophoric gases shall be kept in a continuously mechanically ventilated hood or other continuously mechanically ventilated enclosure. Cylinders of all gases greater than lecture bottle-sized cylinders have a health hazard rating of 3 or 4 and cylinders with a health hazard rating of 2 without physiological warning properties that are located in the laboratory units must be stored in approved continuously mechanically ventilated gas cabinets and comply with NFPA 55, Compressed Gases and Cryogenic Fluids Code. Cylinders of pyrophoric gases that are greater than lecture bottle size located in a laboratory shall be kept in an approved continuously mechanically ventilated, sprinklered gas cabinet. Storage NFPA regulations require flammable liquids to be stored in approved flammable storage cabinets or refrigerators within the laboratory and labeled in conspicuous lettering, "Flammable - Keep Fire Away." Flammable liquids shall be kept in covered containers when not actually in use. Suitable fire control devices such as fire extinguishers must be available at locations where flammable liquids are stored. Keep flammable liquids away from incompatible materials such as oxidizing agents, acids, bases, and plastics. Always follow specific storage guidance provided in the MSDS. NFPA Bulk Storage Requirements: Open flames shall not be permitted in flammable storage areas. Inside storage rooms shall be constructed to meet the required fire-resistive rating for their use NFPA 45 has maximum quantities for the total amount of flammable and combustible liquids allowed in a laboratory.* Research laboratories (Class B) are allowed a maximum quantity of 10 gallons/100ft2 of Class 1 flammable liquids and 20 gallons/100ft2 of Class I, II, and IIIA flammable liquids. Instructional laboratories (Class C) are allowed a maximum quantity of 4 gallons/100ft2 of Class 1 flammable liquids and 8 gallons/100ft2 of Class I, II, and IIIA flammable liquids. NFPA requirements for flammable gases: Storage of flammable gas shall not be located within 50f of air intakes. Static producing equipment located in flammable gas areas shall be grounded. Signs shall be posted in areas containing flammable gases stating that smoking or the use of open flames or both is prohibited within 25ft. of storage. *Referenced from NFPA 45 table 10.1.1 C. Personal Protective Equipment At minimum, safety glasses, lab coat, long pants, and closed toed shoes are to be worn when entering laboratories having hazardous chemicals. Additional information to include: The MSDSs of extremely flammable chemicals may advise using a safety shield any time there is a risk of explosion, splash hazard or highly exothermic reaction. Use flame-retardant lab coats. Do not wear synthetic materials when working with these chemicals. D. Spill and Accident Procedures If there is a spill involving an extremely hazardous chemical, emergency responders should be contacted immediately. Dial 911 during and after normal business hours to contact the local emergency responders for your area and provide detail information to the emergency responders including chemical name, volume, hazards, spill location, and any injuries incurred. Building occupants can be notified of a building evacuation through the activation of a fire alarm pull station. Personnel: If lab personnel is exposed to an extremely hazardous chemical, call 911 immediately. Remove any contaminated clothing, and IMMEDIATELY flush contaminated skin with water for at least 15 minutes following any skin contact. For eye exposures, IMMEDIATELY flush eyes with water for at least 15 minutes. Consult MSDS for guidance on appropriate first aid. Where medical attention is required, ensure to bring along MSDS(s) of chemical(s) to aid medical staff in proper diagnosis and treatment. Fire and Emergency Evacuation Procedures: In case of fire or emergency situation, call 911 and or use emergency blue phone immediately to notify the fire emergency services and campus police. Immediately evacuate the building via the nearest exit when the fire alarm is activated. If unable to evacuate due to a disability, shelter in the area of rescue / refuge, typically a stairwell landing, and wait for assistance from drill volunteers or emergency responders. Instruct visitors and students to evacuate and assist them in locating the nearest exit. Do not use elevators to exit the building during an evacuation as they may become inoperable. Carry only those personal belongings that are within the immediate vicinity. Close doors to limit the potential spread of smoke and fire. Terminate all hazardous operations and power off equipment. Close all hazardous materials containers. Remain outside of the building until the building is released for reentry. Do not restrict or impede the evacuation. Convene in the designated grassy gathering area and await instruction from emergency responders or drill volunteers. Avoid parking lots. Report fire alarm deficiencies, (e.g., trouble hearing the alarm) to facilities personnel for repair. Notify evacuation drill volunteers or emergency responders of persons sheltering in the areas of rescue/ refuge. Never assume that an alarm is a “false alarm”. Treat all fire alarm activations as emergencies. Get out of the building! Laboratory Incident Reporting The Laboratory/Studio and Field Incident Report form is to be completed by the Lab Manager/Teaching Assistant/Instructor for any incident that occurs in any University of South Florida affiliated teaching or research laboratory/studio or field research project. An incident means any unplanned event within the scope of a procedure that causes, or has the potential to cause, an injury or illness and/or damage to equipment, buildings, or the natural environment. Please fill out the online Laboratory/Studio and Field Incident Report form below and submit to Environmental Health & Safety within 24 hours of the incident. Due to medical privacy concerns, no personal identifying information of the person involved in the incident shall be entered or submitted with the form. http://usfweb2.usf.edu/eh&s/labsafety/LabIncident.html E. Waste Disposal All chemical waste generated within USF System laboratories are considered hazardous waste and must be disposed of as hazardous waste in accordance with USF Hazardous Waste Management Procedure, the EPA, and the DEP. The USF Hazardous Waste Management Procedure can be found using the following link, http://compass.custhelp.com/app/answers/detail/a_id/1118/kw/hazardous%20waste. F. Minimum Training Requirements All individuals working with chemicals in USF laboratories must take EH&S’s Laboratory & Research Safety Training. To register for Laboratory & Research Training, please use the following link, http://usfweb2.usf.edu/eh&s/labsafety/tmaterials.html. Depending on the type of extremely hazardous chemicals you will be working with in your lab, additional safety training may be required by the PI, EH&S, or an authorizing unit such as the Biosafety or Radiation Safety programs. G. Approval Required In some instances, prior approval may be required to use an extremely hazardous chemical within the lab. Please consult with PI regarding need for prior approval.
© Copyright 2026 Paperzz