4 1500 c c c 5 6 3000 3 2850 2 150 0 1 8 NOTES : 1. THE FOLLOWING INFORMATION IS OBTAINED FROM THE CONSTRUCTION SCHEDULE : c a. POLE LENGTH AND STRENGTH. 23 0 7 b. SPECIAL FOUNDATION REQUIREMENTS. c. POLE EMBEDMENT DEPTH. c A A d. PHASE CONDUCTOR AND OVERHEAD EARTH WIRE SIZE. 230 e. VARIATIONS TO STANDARD CROSSARM REQUIREMENTS. c 2700 2550 1350 750 150 c 9 10 11 h. ASSESSED EARTHING REQUIREMENTS. 13 2. ALL BOLTS AND INSULATOR PINS PASSING THROUGH TIMBER ARE TO BE COATED 12 c WITH GRAPHITE GREASE. 3. THE MAXIMUM LINE DEVIATION ANGLE TO BE CONSTRUCTED ON THIS ARRANGEMENT c 0 f. STAY REQUIREMENTS. g. DEVIATION ANGLE. IS TO BE DETERMINED BY THE LINE DESIGNER. c c c 4. THE LOAD AND DEVIATION ALLOWABLE ON THE EYEBOLT AND EYENUT ASSEMBLY c 980 IS TO BE DETERMINED FROM DRG : 520331. 5. LONGROD INSULATORS TO BE USED UNDER ALL CONDITIONS. 16 17 18 B B 6. POLES SHALL BE DRILLED, SCARFED AND DRESSED ON SITE. DRILLING AND SCARFING 5 TO BE TREATED WITH APPROVED PRESERVATIVES. 7. WHEN DESIGNING UNDERBUILT CIRCUITS ON A 33kV STRUCTURE, THE POSSIBLE USE OF LIVE LINE WORKING PROCEDURES MUST BE CONSIDERED WHEN NOMINATING THE CIRCUIT SEPARATION TO ALLOW A MINIMUM CLEARANCE OF 2500mm IF REQUIRED. c 1730 15 14 4 6 7 8 22 21 20 19 CONSTRUCTION - THROUGH TERMINATION, 33kV, 4-11 513930 22 WASHER - SPRING, M12, STAINLESS STEEL 518082 6 21 WASHER - FLAT, M12, STAINLESS STEEL 518081 12 20 BOLT & NUT - M12x25mm, HEX., STAINLESS STEEL 515467 6 19 LUG - COMPRESSION (TO SUIT CONDUCTOR) 514053 6 18 WASHER - CONICAL, M16, STAINLESS STEEL 518082 6 17 WASHER - FLAT, M16, GALVANISED 518081 6 16 BOLT & NUT - M16x150mm, HEX., GALVANISED 515466 6 c C 3 c 2730 1 FUSE - LINK, 33kV, 20AMP, CURRENT LIMITING DROPOUT, OUTDOOR USE (S/C H24466) 3 FUSE - LINK, 33kV, 10AMP, CURRENT LIMITING DROPOUT, OUTDOOR USE (S/C H24432) 3 14 BASE - DROPOUT FUSE, 33kV, INCLUDING FUSE END FITTINGS (S/C 24490) 3 13 BRACKET - DROPOUT FUSE, 30 12 BLOCK - GAIN, ALUMINIUM, 100mm (S/C 146274) 11 WASHER - CONICAL, M20, STAINLESS STEEL 518082 2 10 WASHER - SQUARE, 75x75x6mm, GALVANISED (22mm HOLE) 518081 4 9 BOLT & NUT - M20, GALVANISED (LENGTH TO SUIT POLE) 515466 2 8 WASHER - CONICAL, M12, STAINLESS STEEL 518082 1 7 WASHER - FLAT, M12, GALVANISED 518081 1 6 BOLT & NUT - M12x150mm, HEX., GALVANISED 515466 1 5 CROSSARM - 2700x100x100mm, TYPE I, HARDWOOD OR LAMINATED VENEER 514375 2 4 SCREW - COACH, M12x100mm, GALVANISED (S/C H40484) 3 BRACE - CROSSARM, ANGLE, 920x50x50x5mm, GALVANISED 514381 1 2 CONSTRUCTION - HORIZONTAL PIN, 33kV, 4-1 513923 1 1 POLE - TIMBER (AS REQUIRED) (12.5m MINIMUM) 513988 1 15 2 D E 20110909 1 2 ITEM DO NOT SCALE. NETWORK STANDARD DESIGNED DRAWN APP’ D by: GLENN FORD AUSGRI D BORDER APPLI ED. 10/ 2013 DATE: 21/ 6 G CHKED:GARRY CRAI DWN:GARY HUGHES APP’ D by: GLENN FORD SECOND BRACE ADDED TO BOTTOM CROSSARM. 12/ 2010 DATE: 22/ 5 LLI P JONES CHKED:PHI CI A RI OS DWN:PATRI A M E N D M E N TS CAD DRAWI NG F DO NOTMANUALLY AMEND ALL DIMENSIONS IN MILLIMETRES UNLESS NOTED OTHERWISE. - AUTHORISED DATE 145 NEWCASTLE ROAD WALLSEND NSW 2287 P.A.S R.BREMMELL 1:25 MAP REF. LGA PHONE: 02 4951 9388 FAX: 02 4951 9389 PROJECT No. PROJTRAK No. 4 5 SIZE STD 2 A3 - 6 DRAWING No 513957 7 C 3 D 1 E DRG. No QTY STANDARD CONSTRUCTION 33kV THROUGH TERMINATION WITH GREATER THAN 4kA DROPOUT FUSES 4-60 16/04/96 SCALE 517465 DESCRIPTION PETER SAUNDERS CHECKED 3 1 23 F SHEETS AMD. 01 of 1 6 8 C
© Copyright 2026 Paperzz