BUILDING EFFICIENCY Energy Efficient Variable Speed EC Motor Fan Coil Unit Solutions Model YECAH Product Introduction INTRODUCTION Johnson Controls YORK® YECAH ceiling mounted compact cabinet fan coil units are high airflow and high static pressure air-conditioning units using high efficiency 355 mm diameter EC plug fan(s). YECAH fan coil units have been designed incorporating variable speed EC motor technology to meet the needs of today's sustainable building designs and to exceed the stringent European ErP 2015 energy standard . They are the ideal HVAC solution for both new construction and revovation projects for hotels, retail centers, office buildings, and education facilities. The 355 mm diameter EC plug fans operate at lower RPM , lower noise , and higher efficiency levels when compared to ceiling concealed units incorporating multiple fans with smaller diameter impellers. YECAH fan coils are available in 4 models with integral EC fan(s) incorporate fully variable 0-10v speed control, and are suitable for a wide range of chilled water and hot water flow rates, including wide delta T applications to maximize pump energy savings. YECAH fan coil units are available with multiple coil options for each model (the 2 pipe system has 4 or 6 rows, and the 4 pipe system has 4+1, 6+1, 4+2 or 6+2 rows). The air flow ranges from nominal 750 L/s to 1500 L/s, while the external static pressure ranges from 175 Pa to 375 Pa. large removable access panels to the fan section. Cooling and heating coil use copper tubes with corrugated aluminium fins, mounted above a full stainless steel drain pan. The EC plug fan(s) feature EC technology and with a wide RPM range, can satisfy variable Each YECAH unit is made of galvanized steel with 15 mm thick non-combustible airflow and pressure from a 0 - 10 vdc thermal insulation. It contains built-in cooling & heating coils, single or dual EC variable control signal. A MODBUS high level data speed plug fan assemblies, a removable inspection panel with sash catches, and connection is provided as standard. 4R Cooling Coil Only Coils 6R Cooling Coil Only 1R/ 2R Heating Coil GENERAL Motor Protection IP 54 - 50 Hz Fin Protection Hydrophilic Fin Drain Pan Stainless Steel Drain Pan Coil header Copper G1(Nylon) filter Filters & Rails G1(Aluminium mesh) filter G3 Plate filter G4 Plate filter Lengend Thermostat Lengend: Standard Option 2 ENERGY EFFICIENT EC MOTOR AHU SOLUTIONS MODEL YECAH Nomenclature & Feature NOMENCLATURE YECAH 03 D 4 0 0 0 L A York EC Fan Ceiling-mounted AHU Series Unit Size: 03: 750l/s 04: 1000l/s 05: 1250l/s 06: 1500l/s Connection Type: L:Left R:Right 0: Mixed air condition X: Fresh air condition Direct drive 0: no filter A:G1(nylon) B:G1(AL.) C:G3 D:G4 No. of Rows: 4:4Row cooling 6:6Row cooling 0: no heating coil 1: 1R heating coil 2: 2R heating coil FEATURES AND BENEFITS Energy saving Low noise level Coil is made of expanded copper tubes and corrugated fins to achieve high exchange efficiency. 355mm diameter EC plug fans fans provide high efficiency and static capability over wide operation range Each fan and motor assembly has been dynamically and statically balanced Variable speed, low noise, directly driven EC fan Significant energy savings Fan and motor performance rating exceeds the 2015 ErP (European Energy- related Products Directive) Whisper quiet comfort condition results in satisfied occupants. Easy drainage Full Drain pan allows quick and easy drainage of condensation. Drain pan is made of high quality stainless steel. Full drain pan design provides superior condensate management. Compact size & low height Ceiling concealed unit is restricted to 508 mm height to fit within commercial building ceiling spaces Suits many ducted HVAC applications Easy of installation Threaded Brass connector is provided for easy piping connection. Purge valves are provided on all coils to assist in commissioning. Reduces installation and commissioning time and cost. Easy maintenance EC fans are direct drive with sealed for life bearings. Inspection panel allows fast and easy periodic inspection of coil and drain tray. Optional unit mounted filter track Reduced maintenance time and cost. 3 Technical Specifications MODEL Performance Nominal Air Flow Nominal External Static Pressure COIL Face Area Face Velocity Header Material Max Working Pressure COOLING COIL Water Flow Rate Water Pressure Drop Water Content Air Pressure Drop Nominal Capacity YECAH03 YECAH04 YECAH05 YECAH06 L/S Pa 750 175 1000 175 1250 175 1500 175 sq.m m/s 0.284 2.64 0.508 1.97 0.508 2.46 0.610 2.46 Copper 1600 kPa 4 Rows 6 Rows 4 Rows 6 Rows 4 Rows 6 Rows 4 Rows 6 Rows 4 Rows 6 Rows L/S kPa L Pa kW 0.31 0.40 17.2 18.0 3.0 4.6 130 205 9.1 11.7 0.45 0.59 20.2 26.5 3.8 5.7 75 115 13.2 17.4 0.48 0.66 10.3 23.9 3.8 5.7 105 165 14.0 19.3 0.62 0.82 25.8 18.4 4.6 6.8 105 165 18.2 23.8 0.12 0.27 2.0 2.5 0.8 1.5 25 55 9.9 21.6 0.19 0.42 7.5 9.3 0.9 1.9 15 30 15.5 34.2 0.21 0.47 8.8 11.7 0.9 1.9 20 45 16.9 38.6 0.25 0.58 15.0 19.7 1.1 2.3 20 45 20.6 47.0 HEATING COIL Water Flow Rate Water Pressure Drop Water Content Air Pressure Drop Nominal Capacity 1 Row 2 Rows 1 Row 2 Rows 1 Row 2 Rows 1 Row 2 Rows 1 Row 2 Rows MOTOR Type No. of Motor Nameplate Rating Input Control Signal Input Nameplate Amps (220V / 1 Ph. / 50 - 60 Hz.) Nameplate Power Supply FAN Type Quantity UNIT DIMENSIONS Length Width Height Weight(4R Coil) Weight (6R+2R Coil) L/S kPa L Pa kW W V A - 1 750 3.3 Electronically Commutated 1 2 750 750×2 0~10VDC 3.3 3.3×2 230V / 1 Ph. / 50 - 60 Hz 2 750×2 3.3×2 BC SWSI Plug mm mm mm kg kg 1 1 2 2 940 950 508 151 168 940 1500 508 186 210 940 1500 508 201 225 940 1750 508 220 250 Note: 1. Standard mixed air cooling conditions: air inlet at 23°C DB/17°C WB; chilled water inlet/outlet at 6°C/13°C. 2. Cooling Coil APD at wet condition. 3. Heating Coil APD at dry condition. 4. The weight listed in the table is the shipping weight. 5. The weight does not include water volumes. 4 ENERGY EFFICIENT EC MOTOR AHU SOLUTIONS MODEL YECAH Technical Specifications YECAH Air Flow Range Unit Model YECAH06 YECAH05 YECAH04 YECAH03 250 500 750 1000 1250 1500 1750 Air Flow L/s 5 Technical Specifications MOTOR POWER INPUT(W) MODEL 4 Rows Cooling Coil+1 Row Heating Coil ESP (Pa) 550 L/S 680 L/S 750 L/S 175 391 567 744 225 YECAH03 460 L/S 620 L/S 730 L/S 377 560 741 275 360 L/S 540 L/S 680 L/S 360 545 742 325 460 L/S 620 L/S 531 734 720 L/S 870 L/S 565 738 1190 L/S 1350 L/S 1125 1450 375 MODEL ESP (Pa) 750 L/S 910 L/S 1040 L/S 175 390 543 715 225 YECAH04 680 L/S 850 L/S 990 L/S 396 555 727 275 590 L/S 790 L/S 930 L/S 393 562 732 325 375 MODEL ESP (Pa) 900 L/S 1160 L/S 1350 L/S 175 498 819 1161 225 YECAH05 800 L/S 1110 L/S 1290 L/S 527 782 1130 275 940 L/S 1250 L/S 1350 L/S 765 1138 1350 325 375 MODEL ESP (Pa) 990 L/S 1350 L/S 1620 L/S 175 503 774 1088 225 YECAH06 275 325 375 1190 L/S 1500 L/S 1620 L/S 767 1071 1200 980 L/S 1390 L/S 1620 L/S 755 1090 1450 1240 L/S 1550 L/S 1080 1451 380 L/S 550 L/S 512 736 630 L/S 800 L/S 553 738 1010 L/S 1330 L/S 1154 1486 1050 L/S 1430 L/S 1074 1448 6 ENERGY EFFICIENT EC MOTOR AHU SOLUTIONS MODEL YECAH MOTOR POWER INPUT(W) MODEL 6 Rows Cooling Coil+1 Row Heating Coil ESP (Pa) 570 L/S 680 L/S 700 L/S 175 530 715 745 225 YECAH03 460 L/S 610 L/S 630 L/S 507 704 744 275 350 L/S 520 L/S 550 L/S 477 683 745 325 410 L/S 480 L/S 645 743 690 L/S 840 L/S 571 738 1120 L/S 1350 L/S 1120 1480 375 MODEL ESP (Pa) 740 L/S 890 L/S 1010 L/S 175 398 545 713 225 YECAH04 660 L/S 830 L/S 970 L/S 396 554 735 275 570 L/S 760 L/S 900 L/S 397 559 737 325 375 MODEL ESP (Pa) 910 L/S 1200 L/S 1350 L/S 175 525 806 975 225 YECAH05 1080 L/S 1250 L/S 1350 L/S 793 975 1139 275 960 L/S 1240 L/S 1350 L/S 787 1131 1350 325 375 MODEL ESP (Pa) 910 L/S 1260 L/S 1550 L/S 175 483 770 1082 225 YECAH06 1140 L/S 1410 L/S 1620 L/S 758 1090 1450 275 325 375 980 L/S 1280 L/S 1590 L/S 747 1086 1457 1180 L/S 1480 L/S 1071 1456 330 L/S 400 L/S 626 743 620 L/S 770 L/S 565 737 1020 L/S 1260 L/S 1108 1483 1050 L/S 1360 L/S 1049 1450 Note: Airflow and inputpower datas are for dry coil and without filter. 7 Performance Data PERFORMANCE RATINGS Model Air Inlet Temp(Dry Bulb/Wet Bulb) 27℃/19℃ Air Inlet Temp(Dry Bulb/Wet Bulb) 23℃/17℃ Air Inlet Temp(Dry Bulb/Wet Bulb) 35℃/24℃ Inlet Air Off Air Off Air Off Chilled Total Sensible Water Water Total Sensible Water Water Total Sensible Water Water Airflow Rows Temp Temp Temp Water Cooling Cooling Flow Pressure Cooling Cooling Flow Pressure Cooling Cooling Flow Pressure (Dry Bulb/ (Dry Bulb/ (Dry Bulb/ Temp Capacity Capacity Rate Drop Capacity Capacity Rate Drop Capacity Capacity Rate Drop Wet Bulb) Wet Bulb) Wet Bulb) L/S ℃ kW kW ℃ L/S kPa kW kW ℃ L/S kPa kW kW ℃ L/S kPa 4 YECAH03 750 6 4 YECAH04 1000 6 4 YECAH05 1250 6 4 YECAH06 COOLING COIL 1500 6 5 6 7 8 9 5 6 7 8 9 5 6 7 8 9 5 6 7 8 9 5 6 7 8 9 5 6 7 8 9 5 6 7 8 9 5 6 7 8 9 14.5 13.0 11.6 10.4 9.3 18.2 16.4 14.8 13.2 11.7 20.0 18.1 16.3 14.5 12.9 26.6 24.1 21.6 19.3 17.2 22.2 19.9 17.9 15.9 14.1 29.0 26.4 23.9 21.3 18.9 28.0 25.3 22.8 20.4 18.2 36.5 33.0 29.6 26.4 23.4 10.8 10.1 9.5 9.0 8.4 12.9 12.1 11.3 10.7 10.0 14.4 13.5 12.7 11.9 11.2 18.5 17.3 16.2 15.2 14.3 16.7 15.6 14.7 13.8 12.8 20.5 19.3 18.2 17.0 15.9 20.7 19.5 18.3 17.2 16.1 25.9 24.3 22.8 21.4 20.1 14.9/13.2 15.7/13.9 16.3/14.4 17.0/15.0 17.6/15.4 12.6/11.5 13.5/12.3 14.3/13.1 15.1/13.8 15.8/14.4 14.9/13.0 15.7/13.6 16.3/14.2 17.0/14.8 17.6/15.3 11.5/10.7 12.5/11.6 13.4/12.4 14.2/13.2 15.0/13.9 15.8/13.7 16.5/14.3 17.1/14.8 17.8/15.3 18.4/15.8 13.3/11.9 14.0/12.6 14.8/13.3 15.6/14.0 16.3/14.6 15.4/13.4 16.1/14.0 16.7/14.5 17.4/15.1 18.0/15.5 12.5/11.5 13.4/12.3 14.2/13.1 15.0/13.8 15.8/14.4 0.50 0.44 0.40 0.35 0.32 0.62 0.56 0.50 0.46 0.40 0.68 0.61 0.56 0.50 0.44 0.91 0.83 0.74 0.66 0.59 0.76 0.68 0.61 0.54 0.48 0.98 0.90 0.82 0.72 0.64 0.95 0.86 0.78 0.69 0.62 1.24 1.12 1.01 0.89 0.79 36.7 30.5 25.3 21.3 17.5 37.1 30.7 25.8 21.8 17.4 41.4 34.1 29.5 23.6 19.1 58.3 48.4 39.3 32.4 26.0 23.9 19.2 16.1 12.7 10.2 47.7 41.7 35.2 28.1 22.6 55.6 46.6 39.4 31.6 25.5 40.2 33.5 27.3 21.6 17.4 10.5 9.1 7.8 6.6 5.7 13.4 11.7 10.2 8.7 7.5 15.0 13.2 11.4 9.8 8.4 19.9 17.4 15.1 13.0 11.0 15.9 14.0 11.9 10.1 8.7 22.0 19.3 16.8 14.4 12.4 21.0 18.2 15.9 13.7 11.7 27.2 23.8 20.5 17.6 14.9 8.1 7.5 6.8 6.2 5.6 9.8 9.0 8.3 7.6 6.9 11.0 10.2 9.4 8.6 7.8 14.2 13.0 12.0 11.0 10.0 12.5 11.6 10.5 9.5 8.5 15.9 14.6 13.4 12.3 11.3 15.9 14.6 13.5 12.3 11.1 19.9 18.3 16.8 15.4 13.9 14.0/12.7 14.7/13.3 15.4/13.9 16.1/14.3 16.8/14.7 12.2/11.3 13.0/12.1 13.8/12.8 14.6/13.5 15.3/14.0 13.9/12.3 14.5/12.9 15.2/13.5 15.9/14.0 16.5/14.5 11.3/10.6 12.2/11.5 13.1/12.3 13.9/13.0 14.7/13.6 14.7/13.1 15.3/13.6 16.0/14.1 16.7/14.6 17.3/14.9 12.5/11.4 13.3/12.2 14.1/12.9 14.8/13.5 15.5/14.0 14.2/12.7 14.9/13.3 15.6/13.8 16.2/14.2 16.9/14.7 12.0/11.2 12.9/12.0 13.7/12.8 14.5/13.4 15.3/14.0 0.35 0.31 0.27 0.23 0.20 0.46 0.40 0.35 0.29 0.25 0.51 0.45 0.39 0.34 0.29 0.68 0.59 0.51 0.44 0.38 0.54 0.48 0.41 0.34 0.29 0.75 0.66 0.57 0.49 0.42 0.72 0.62 0.54 0.47 0.39 0.93 0.82 0.70 0.60 0.50 22.0 17.2 12.9 9.7 7.4 22.6 18.0 14.4 10.5 8.2 24.9 20.2 15.3 11.5 8.8 34.3 26.5 20.6 15.4 11.3 12.9 10.3 7.5 5.5 4.1 30.6 23.9 18.6 14.0 10.5 34.1 25.8 20.3 15.4 11.1 23.7 18.4 13.7 10.3 7.3 25.1 23.6 21.8 20.1 18.6 28.2 26.5 24.6 22.8 20.9 29.5 27.4 25.0 23.1 21.1 38.1 35.5 32.9 30.2 27.6 37.5 34.6 32.0 29.3 26.6 42.4 39.3 36.3 33.6 30.6 47.0 44.0 40.7 37.6 34.7 56.8 53.2 49.5 45.9 42.0 16.1 15.5 14.8 14.1 13.5 17.6 16.9 16.0 15.3 14.6 19.0 18.2 17.2 16.4 15.6 24.0 22.9 21.8 20.8 19.8 24.5 23.4 22.3 21.2 20.2 27.0 25.6 24.4 23.3 22.2 30.3 29.1 27.8 26.5 25.3 35.6 34.0 32.5 31.0 29.4 16.6/15.0 17.2/15.6 18.1/16.3 18.9/17.0 19.6/17.6 14.9/13.6 15.7/14.4 16.7/15.2 17.5/16.0 18.4/16.7 18.7/16.2 19.4/16.9 20.3/17.6 20.9/18.1 21.6/18.7 14.4/13.5 15.4/14.3 16.3/15.2 17.2/16.0 18.1/16.8 18.2/16.1 19.0/16.8 19.7/17.4 20.5/18.0 21.2/18.6 16.5/14.8 17.4/15.6 18.3/16.4 19.0/17.0 19.8/17.7 17.7/15.7 18.3/16.3 19.1/16.9 19.9/17.5 20.5/18.1 14.7/13.5 15.5/14.3 16.5/15.1 17.3/15.9 18.2/16.7 0.85 0.81 0.75 0.68 0.63 0.96 0.91 0.84 0.78 0.71 1.01 0.94 0.85 0.79 0.72 1.29 1.20 1.12 1.03 0.94 1.28 1.17 1.10 1.00 0.90 1.44 1.34 1.23 1.14 1.04 1.60 1.50 1.38 1.29 1.18 1.92 1.81 1.69 1.57 1.43 43.7 39.7 34.2 29.0 26.0 26.5 24.1 20.6 18.3 15.7 13.3 11.5 9.6 8.5 7.1 18.7 16.4 14.2 12.1 10.2 19.1 16.0 14.1 11.8 9.8 17.1 14.8 12.6 11.0 9.1 44.0 39.0 33.4 29.2 25.6 33.2 28.8 25.4 22.2 18.4 Note: The temperature difference of inlet/outlet water is 7°C 8 ENERGY EFFICIENT EC MOTOR AHU SOLUTIONS MODEL YECAH Performance Data PERFORMANCE RATINGS HEATING COIL Air Inlet Temp(Dry Bulb) Airflow Rows Model YECAH04 YECAH05 YECAH06 21℃ 15℃ Total Heating Capacity Air Off Temp Water Flow Rate Water Total Pressure Heating Drop Capacity ℃ kW ℃ L/S kPa 1 80 9.9 31.9 0.12 2 80 21.6 44.8 1 80 15.5 2 80 1 7℃ Air Off Temp Water Flow Rate kW ℃ L/S kPa 2.0 11.3 27.3 0.14 0.27 2.5 24.8 41.8 33.8 0.19 7.5 17.6 34.2 49.3 0.42 9.3 80 16.9 32.2 0.21 2 80 38.6 46.6 1 80 20.6 2 80 47.0 L/S YECAH03 Inlet Hot Water Temp Water Total Pressure Heating Drop Capacity Air Off Temp Water Flow Rate Water Pressure Drop kW ℃ L/S kPa 2.6 13.2 20.9 0.16 3.53 0.30 3.2 29.1 37.7 0.36 4.36 29.3 0.21 9.6 20.4 23.1 0.25 12.67 39.0 46.7 0.48 12.0 45.5 42.9 0.56 15.93 8.8 19.3 27.5 0.23 11.3 22.4 21.1 0.28 15.09 0.47 11.7 44.0 43.6 0.54 14.9 51.3 39.4 0.63 20.03 32.4 0.25 15.0 23.4 27.7 0.29 19.2 27.2 21.3 0.33 25.38 46.9 0.58 19.7 53.5 43.9 0.66 25.1 62.3 39.8 0.76 33.75 750 1000 1250 1500 9 Acoustics SOUND POWER LEVEL Model ESP(Pa) YECAH03 175 YECAH04 YECAH05 YECAH06 4 Rows Cooling Coil+1 Row Heating Coil Air Flow (L/S) 63Hz 125Hz 250Hz 500Hz 1kHz 2kHz 4kHz 8kHz dB(A) 550 32.2 44.4 45.9 48.2 47.4 42.1 38.6 36.5 53.4 750 37.3 48.8 52.3 51.7 53.1 48.3 41.5 40.5 58.4 800 26.4 47.8 45.0 50.9 56.4 51.8 46.9 43.1 59.4 1000 30.1 43.2 47.9 53.2 58.6 53.8 48.9 44.8 61.3 1050 28.7 45.9 46.3 49.5 48.9 41.6 36.3 34.2 54.3 1250 31.2 45.8 48.6 53.4 52.2 44.0 37.9 35.6 57.3 1300 28.5 45.1 47.6 49.5 49.4 39.7 34.6 33.0 54.5 1500 31.1 45.0 49.6 52.1 51.9 41.5 35.4 34.4 56.7 175 175 175 SOUND POWER LEVEL Model ESP(Pa) YECAH03 175 YECAH04 YECAH05 YECAH06 6 Rows Cooling Coil+1 Row Heating Coil Air Flow (L/S) 63Hz 125Hz 250Hz 500Hz 1kHz 2kHz 4kHz 8kHz dB(A) 550 34.4 45.8 47.9 51.5 52.4 48.7 42.7 38.9 57.2 700 37.2 48.8 51.1 52.7 55.1 51.2 45.3 40.4 59.5 800 29.0 43.7 49.0 53.5 55.2 51.8 45.0 40.2 59.3 1000 34.6 46.5 51.8 54.6 58.2 52.9 45.6 42.9 61.4 1050 36.7 50.6 52.9 52.7 52.2 42.5 34.4 30.1 58.4 1250 38.0 52.0 56.4 55.4 55.6 45.4 38.8 31.4 61.3 1300 31.6 48.2 50.7 52.6 52.5 42.8 37.7 36.1 57.6 1500 34.4 48.3 52.9 55.4 55.2 44.8 38.7 37.7 60.0 175 175 175 Casing Radiated Sound Power Test: According to JBT4330-1999 and ISO3744, casing radiated sound power level is tested in hemi-anechoic room. Unit tested with 3 meters of inlet and 3 meters of outlet ductwork. 10 ENERGY EFFICIENT EC MOTOR AHU SOLUTIONS MODEL YECAH Units Drawings Cooling Only 11 Units Drawings Cooling and Heating W Outlet flange size Inlet flange size Piping position Model J K HK HN B D E P 4 rows 6 rows 1 row 2 rows 1 row 2 rows YECAH03 950 326 450 804 160.5 182.5 66 110 44 66 407 420 YECAH04 1500 451 600 1360 160.5 182.5 66 110 44 66 407 420 YECAH05 1500 329 950 1360 160.5 182.5 66 110 44 66 407 420 YECAH06 1750 376 1200 1610 160.5 182.5 66 110 44 66 407 420 with 1R HC with 2R HC Notes: 1. The coil pipe connections use male threads(thread code R2) 1" - OD 34mm 1 1/2" - 48mm 2. The condensate pipe connections use 34mm O.D. male threads(thread code R2) 3. All dimensions are SI unit(mm) 12 ENERGY EFFICIENT EC MOTOR AHU SOLUTIONS MODEL YECAH Fan Performance Curves YECAH03 4R Cooling+1R Heating YECAH03 6R Cooling+1R Heating Note: Airflows are for dry coil and without filter. Reduce airflow by 10% in high moisture removal conditions. Note: Airflows are for dry coil and without filter. Reduce airflow by 10% in high moisture removal conditions. YECAH04 4R Cooling+1R Heating YECAH04 6R Cooling+1R Heating Note: Airflows are for dry coil and without filter. Reduce airflow by 10% in high moisture removal conditions. Note: Airflows are for dry coil and without filter. Reduce airflow by 10% in high moisture removal conditions. 13 Fan Performance Curves YECAH05 4R Cooling+1R Heating YECAH05 6R Cooling+1R Heating Note: Airflows are for dry coil and without filter. Reduce airflow by 10% in high moisture removal conditions. Note: Airflows are for dry coil and without filter. Reduce airflow by 10% in high moisture removal conditions. YECAH06 4R Cooling+1R Heating YECAH06 6R Cooling+1R Heating Note: Airflows are for dry coil and without filter. Reduce airflow by 10% in high moisture removal conditions. Note: Airflows are for dry coil and without filter. Reduce airflow by 10% in high moisture removal conditions. 14 ENERGY EFFICIENT EC MOTOR AHU SOLUTIONS MODEL YECAH Electrical Data and Wiring MOTOR WIRING TAG Power supply 230V ~ 50Hz Alarm relay Interface 0-10VDC output for Modbus Input Field wiring by User QF Wiring in Factory NB1 L N PE NC C RSA RSB 0-10V GND 10V M ~ Notes: Fan Motor(MF) NB1 Option control interface: RS485 interface for Modbus. L N PE NC 8 COM 10V 7 AI 6 B 5 A 4 NC2 NC C C NC1 NC PE PE 1 Motor Terminals N 2 L User Terminals(TB) NB2 C RSA RSB 0-10V GND 10V M ~ Fan Motor(MF) NB3 NB2 Terminal 10V: Fixed voltage output 10VDC, max 10mA. Fan Motor will run at full speed if 10V and AI terminals are shorted. NB3 Single Fan Motor units do not have these parts of wiring. 15 TEC3000 Series Thermostat Controllers TEC3000 Series Thermostat Controllers are stand-alone and field-selectable BACnet® Master-Slave/Token-Passing (MS/TP) or N2 networked devices that provide on/off, floating, and proportional control of two or four-pipe fan coils with variable-speed EC motors (0 to 10 VDC control) Some models have occupancy sensing capability built into the device. These thermostat controllers can deliver further energy savings of up to 30% by using additional standby set-points. These thermostats feature two configurable binary inputs that provide for advanced functions such as remote night The networked models feature a fieldsetback, service or filter alarms, motion selectable Building Automation System detector, and key switch or window status, (BAS) BACnet MS/TP or N2 communication and configures the application to respond capability that enables remote monitoring accordingly. and programming for efficient space temperature control. A Full Line of Remote TE-6300 Series Temperature Sensors supports a wide All models include a USB port configuration range of applications. that reduces installation time by allowing simple backup and restore features from a USB drive, which enables rapid cloning of the configuration between like units. All models feature an intuitive user interface with backlit display that makes setup and operation quick and easy. The Backlit Liquid Crystal Display (LCD) offers real-time control status of the environment in easy-to-read, plain text messages with adjustable backlight that brightens during user interaction. 16 ENERGY EFFICIENT EC MOTOR AHU SOLUTIONS MODEL YECAH Guide Specifications GENERAL Furnish and install ceiling-mounted compact air handling units not exceding 508mm height as indicated and scheduled in the plans. Units shall be factory assembled with coils that are pressure tested individually to 400 psi (2.8 MPa). The unit shall incorporate one or two 355mm diameter directly driven EC plug fans with integral variable speed drive(s). The units shall be suitable for operation on 240 volt single phase 50 hz power. BASIC UNIT The unit panels shall be fabricated out of 1mm galvanized steel. The unit shall be lined with 15 mm Class 1 PE thermal insulation. The fan motor(s) shall be easily removable for serviceability. A terminal box with terminal strip shall be provided for terminating the wiring. An inspection panel with sash catches shall be provided for easy inspection of coil and drain pan. COILS Copper tube with corrugated aluminum hydrophilic fins. Aluminum fins shall be 0.110mm thick and the coil shall have maximum spacing of 2.3mm between the fins. The coil shall be pressure tested under water to 2.8 MPa (For a working pressure of 1600 kpa) and dehydrated before assembly. Coil shall be provided with a manual air vent on the top. The coil assembly shall be protected on the side on which piping is to be fitted with a cover made of GI sheet. A full drain pan shall be provided to the base of the unit manufactured of stainless steel to prevent corrosion. MOTORS TERMINAL BOX All units shall be provided with factory installed terminal box with the fan motor wired to the box. the terminal box shall include a DIN rail type terminal strip that has connections for incoming 240v power, 0-10v dc speed control, a common fault contact, and a MODBUS high level data interface. Where multiple fans are provided they shall be factory wired to the common terminal strip. High efficiency electronically commutated (EC) motors shall be fitted as standard on all units. Motor can be regulated by 0-10V FILTER dc signal supplied by a BMS, thermostat As an option, panel filters shall be provided or DDC controller. The motor is resiliently to a 25mm channel frame mounted on the mounted, self aligning and oiled for life. air inlet of the unit. A MODBUS high level connection shall be provided. FANS The unit shall utilize one or two 355mm diameter EC plug fan(s), dynamically balanced, incorporating backward curved impellers each with a direct drive EC motor. The fan motor assembly shall be designed for low-noise, variable speed operation from a 0-10v dc control input. EC fan assemblies shall be installed in an insulated plenum section with large removable access panels fitted to both sides of the air handling unit for ease of service and replacement. 17 Solutions for your success Every building is unique in design and technical requirements. Our customers always receive customised building solutions to meet their individual needs. Johnson Controls can handle many challenges with its innovative and flexible solutions. From A to Z, from consulting to planning, installation, maintenance (service, inspection and repair) and modernisation – Johnson Controls supports customers throughout the entire life cycle of a building. High Efficiency Chiller Building Automation & Chiller Plant Optimization Variable Air Volume 18 ENERGY EFFICIENT EC MOTOR AHU SOLUTIONS MODEL YECAH Our well thought-out solutions guarantee a high level of comfort and energy efficiency. The majority of our products are already rated as Class A for Energy Efficiency, with high levels of compatibility and flexibility allowing for future additions to be carried out without difficulty. External systems can be easily integrated using BACnet® or proprietary solutions. Our service team is available to you 24 hours a day with one of the largest service networks in Europe. EC Motor AHUs EC Motor FCUs EC Motor Ceiling AHUs Service Solutions Energy Management & Reporting 19 Office Locations Australia (Melbourne) Tel: +61 (3) 9751 5000 Fax: +61 (3) 9755 7566 Indonesia Tel: +62 (21) 5366 8500 Fax: +61 (21) 5366 8300 Malaysia (Kuala Lumpur) Tel: +60 (3) 7628 4300 Fax: +60 (3) 7874 1180 China (Shanghai) Tel: +86 (21) 6276 6509 Fax: +86 (21) 6277 3543 Japan Tel: +81 (3) 5738 6100 Fax: +81 (3) 5738 6298 New Zealand Tel: +64 (9) 444 6434 Fax: +64 (9) 444 2092 Hong Kong Tel: +852 2590 0012 Fax: +852 2516 5648 Korea Tel: +822 554 5935 Fax: +822 554 5739 Singapore Tel: +65 6748 0202 Fax: +65 6743 4420 India (Mumbai) Tel: +91 (22) 6617 4107 Fax: +91 (22) 6683 7002 Macau Tel: +853 2875 1820 Fax: +853 2875 1825 Thailand (Bangkok) Tel: +66 (2) 717 1260-80 Fax: +66 (2) 717 1325-8 PUBL-7895 (1215)
© Copyright 2026 Paperzz