DGTiex Digital Gas Detector Conforms with the ATEX directive for use in Zone 1 and 2 areas Excellent resistance against chemical attack Also for oxygen free environment Non-intrusive parameter setting and calibration via IR link • • • • AVACO DGTiex gas detector is designed for detecting carbon dioxide, methane, hydrocarbons or acetylene. It is certified for use in Zone 1 and 2 areas. NDIR (Non Dispersive Infrared) sensor used in DGTiex enables reliable operation in very demanding environments. C2H2 CH4 C5H12 C3H8 NDIR sensor is resistant to chemical attack by most weak acids, solvents, bases and corrosive gases. DGTiex operates also in oxygen free environments. CO2 C2H5OH APPLICATION • • • • • • Process industry Chemical industry Metal industry Oil industry Natural gas stations Printing houses ISO 9001:2000 C5H10 C6H14 ATEX DGTiex Digital Gas Detector NDIR NDIR NDIR Acetone (C3H6O) ● Carbon Dioxide (CO2) ● Pentane (C5H12) ● Acetylene (C2H2) ● Propanol (iso-) (C3H8O) ● Propane (C3H8) ● Butane (C4H10) ● Xylene (C8H10) ● Toluene (C7H8) ● Ethanol (C2H6O) ● Methane (CH4) ● Cyclohexane (C6H12) ● Hexane (C6H14) ● Methanol (CH4O) ● Cyclopentane (C5H10) ● Heptane (C7H16) TYPICAL RANGE ● Octane (C8H18) ● Other combustible gases: ask the manufacturer Carbon dioxide 0…5 % vol Other gases 0…100 % LEL OUTPUT SIGNAL 4…20 mA, linear response OPERATING VOLTAGE 24 V DC ±20%, 120mA (max) T90 RESPONSE TIME (typical) < 60 seconds OPERATING HUMIDITY 0…95% RH, non-condensing OPERATING TEMPERATURE -20…+40°C OPERATING PRESSURE Normal air pressure +/-10% INGRESS PROTECTION IP65 WEIGHT 1,66 kg ENCLOSURE Aluminium, Ø110mm, d127mm CALIBRATION The detectors are factory calibrated according to the measuring range The calibration and maintenance services shall be carried out by authorized maintenance personnel INSTALLATION Installation instructions follow the delivery. The installation has to be done according to the EN 60079-14 standard. ACCESSORIES Stainless steel protection cover, ceiling assembly kit Pipe assembly kit VTT 07 ATEX 028 (Notified Body Number 0537) II 2 G Ex d IIC T5 Equipment or Protective Systems Intended for use in Potentially explosives atmospheres Directive 94/9/EC Compliance with the Essential Health and Safety Requirements has been assured by compliance with EN 60079-0 (2004) EN 60079-1 (2004) DETECTOR Oy reserves the right to make any changes, without notice, to the technical characteristics of it’s equipment DETECTOR Oy Telekatu 8 FI-20360 TURKU FINLAND Tel. +358 207 756 480 Fax +358 207 756 498 www.detector.fi [email protected] Code No. 20715522 rev. 1.4 Hammarvägen 1 232 37 Arlöv [email protected] 040 - 664 28 50 www.palgo.se
© Copyright 2026 Paperzz