341E.3 Measuring transducers G 400 for phase angle PF 400 for cos ϕ proportional PF400-FA The G 400 measures the angle between sine wave formed current and voltage. The output signal is proportional to the angle in degrees. There are two models, one for single-phase and one for 3-phase systems. The PF 400 for cos ϕ measures the angle between sine wave formed current and voltage. The output signal is proportional to cos phi. There are two models, one for single-phase and one for threephase systems. The transducers in plastic cases are mounted directly on profiled bar 35 EN 500022. Connection to selfopening clamps for 6 mm2 wires. Transducers for mounting in 19" racks can be delivered in different application types (see special leaflet). The rack modules are 8 TE wide and in a 19" rack is place for 10 modules. The transducers are manufactured according to IEC 688. PF400-FB Order facts: Enclosed for mounting on profiled bar 35 EN 50022 Angle deg cos ϕ Type Type Single phase G 400-15x PF 400-15x Three phase G 400-35x PF 400-35x 19" rack module (width 8 TE) Angle deg cos ϕ Type Type G 400R-15x PF 400R-15x G 400R-35x PF 400R-35x Replace x with last digit for output according to table below External Output resistance load Last digit x 0 -5 or ± 5 mA 0-3000 Ω 1 0 -10 or ± 10 mA 0-1500 Ω 2 0 -20 or ± 20 mA 0- 750 Ω 3 4 -20 mA 0- 750 Ω 4 0 -10 or ± 10 V > 700 Ω 5 Order form: Measuring transducer Type Connection Range Output Power supply Case for DIN-rail for cos ϕ, three phase PF 400-354 110 V, 5A, 50 Hz cap. 0,5-1-0,5 ind. 4 - 12 - 20 mA 230 VAC Technical data Input Voltage any value between 10 and 500V (rack version max 300 V) Consumption (burden) < Uin × 2 mA, VA Current any value between 0,5 and 7,5 A Consumption approx. 0,2 VA Frequency 50 or 60 Hz Measuring ranges min 60 deg., max 360 deg. Common measuring cap 0,5-1-0,5 ind ranges cap 0,9-1-0,9 ind Output Current output signal min 0-1 mA, max 0-20 mA Range 0...5/10/20 mA, 4-20 mA Load max 15 V Current limitation < 30 mA Voltage: 0-10 V Burden > 700 Ω Ripple < 1% p.p. General data Accuracy class 0,5 according to IEC 688 0,2 on request Linearity error < 0,1% Response time 2 periods Temperature influence < 0,1% / 10°C Temperature range 25...+60°C operation 40...+70°C storage Test voltage 5,6 kV, 50 Hz, 1 min (rack version 3,7 kV) Power supply 24, 110, 230 VAC ± 15%, 47-70 Hz, ca 2 VA 24-130 VDC ± 20%, ca 2,5 W Weight 0,5 kg Options on request Standards General standards for measuring transducers EN 60688, IEC 688 EMC emission EN 50081-2 immunity EN 50082-2 * Safety EN 61010-1, IEC 1010-1 Inputs overvoltage cat III Outputs overvoltage cat II Pollution degree 2 *) At certain frequences can minor deviations from class accuracy occur during the disturbance HUGO TILLQUIST AB • SWEDEN Box 1120 • SE-164 22 KISTA • Tel +46 8 594 632 00 • Fax +46 8 751 36 95 • www.tillquist.com 341E.3 Design GPF400BB The two input quantities voltage and current are transformed in the input transformer to a level adapted to the internal electronics and give at the same time galvanic separation. The noise on the input signals is filtered away in the phase true lowpass filter. In the following zero cross detector (Schmitt trigger) is the input sine wave converted to a square wave. The micro processor calculates the exact time difference T1 between the two input signals. Out of the relation T1/T is either the phase angle (G) or the cosine (PF) between voltage and current calculated. The AC power supply comes from a transformer that gives a galvanic separation. Those parts that need separate power get it via a rectifying stage. The DC power comes from a switched unit that gives galvanic separation and covers the span from 24 to 130 VDC. Connecting diagrams G/PF 400 GPF400AE G/PF 400R GPF400RE Dimensions (mm) G/PF 400 PQ400ME G/PF 400R 400RM3 HUGO TILLQUIST AB • SWEDEN Box 1120 • SE-164 22 KISTA • Tel +46 8 594 632 00 • Fax +46 8 751 36 95 • www.tillquist.com
© Copyright 2026 Paperzz