Fire detector and accessories Interactive optical smoke detector Connection terminal block Base Installation specification Head Detectors must be mounted with their head down. They must always be with flush with the ceiling. Characteristics Mechanical characteristics Dimensions (∅ x H) in mm Storage conditions 104 x 55 130 g Weight Color Temperature off-white (other colors on order) Head to base lock By ¼ turn Protection index IP32 Material ABS from +10°C to +50°C Humidity <85% RH Operating conditions Temperature Consumption EN54-7, EN54-9 from 12V to 28V standby: alarm: out-of-order: <93% RH Conformity Electrical characteristics Power supply voltage from - 10°C to +60°C Humidity 150 to 500μA 5mA at 24V 140μA Radiated fields Electrostatic discharges 10v/m from 80 MHz to 1GHz 8 kV air / 6 kV contact Fast transient Induced disturbances 1 kV 10 V 150 kHz to 100 MHz High energy 1kV Special features This detector is fixed to the ceiling with its head down. Different technologies can be mixed on the same line with no particular restrictions. Solutions et services de Systèmes de Sécurité Incendie. La D é t e c t i o n E l e c t r o n i q u e Fr a n ç a i s e - S I E G E S O C I A L : Pa r c d ' A c t i v i t é s d u M o u l i n d e M a s s y - 9 , r u e d u S a u l e Tr a p u B P 2 1 1 9 1 8 8 2 M a s s y C e d e x Fr a n c e - T é l : + 3 3 ( 0 ) 1 6 0 1 3 8 1 8 1 - Fa x : + 3 3 ( 0 ) 1 6 0 1 3 8 1 0 0 - e - m a i l : c o n t a c t @ d e f - o n l i n e . f r Document et photos non contractuels. MKT/FTP/2006/083-A Addressable system OA-O 01DT080 Interactive optical smoke detector ORION Interactive detector. Monitoring of the sensitive element. 8 alarm levels. Certified conform with EN54 parts 7 and 9 NF No. L 050 Presentation The OA-O detector is an smoke detector. It is based on the principle of the « Tyndall effect » caused by diffusion of light by particles. The variation of intensity perceived by the infrared receiver is analyzed by a programmed electronic unit that makes a decision about the state of the detector and outputs the electronic result signal of the analysis made by the sensor. The basic version of the monitored electronic unit has 8 preprogrammed detection levels, so that a malfunction signal can be sent if there is a failure of the sensitive element. A change in the threshold level can be programmed in the time cycles, as a function of the associated control unit. This detector comprises a red light indicator used for signaling of the fire alarm. An output is used for remote repetition of this information. The OA-O detector included an isolator of short circuit. It is made using internal processes and its discrete and modest appearance blend it into any type of decoration. Compatibility Control units and ECS Compatible bases Altair and Cassiopée Range EO (Base) 00DT066 IA (Action indicator) 02IA002 IAE (Sealed action indicator) 02IA003 Compatible action indicators Support étiquette OSET 00DT076
© Copyright 2026 Paperzz