Solenoid/pneumatic valves, ISO 5599-1

Solenoid/pneumatic valves, ISO 5599-1
• Electrically or pneumatically actuated
valves
• With internal or external pilot air
• Pneumatic or mechanical reset
Specified types in accordance with ATEX
directive for potentially explosive atmospheres
www.festo.com/en/ex
2013/01 – Subject to change
Internet: www.festo.com/catalogue/...
1
Solenoid valves, ISO 5599-1
Product range overview
Function
Version
5/2-way valves,
single solenoid
Solenoid valve
Type
MN1H
MFH
MDH
Solenoid valve with central plug M12x1
MEBH-…-ZSR
ISO size
Nominal flow
rate
[l/min]
Pneumatic working
port on sub-base
1
2
3
1
2
3
4
1,200
2,300
4,500
1,200
2,300
4,500
6,000
1
2
3
1,200
2,300
4,500
[V DC]
[V AC]
G¼
Gy
G½
G¼
Gy
G½
G¾
24
110, 230
12, 24, 42
24, 42, 48,
110, 230, 240
24
42, 110, 230
G¼
Gy
G½
24
–
24
–
Solenoid valve with single plug M12x1, connector pin allocation to VDMA or Desina
MDH
1
1,200
G¼
2
2,300
Gy
3
4,500
G½
5/2-way valves,
double solenoid
Double solenoid valve
JMN1H
1
2
3
1,200
2,300
4,500
G¼
Gy
G½
24
110, 230
1,200
2,300
4,500
G¼
Gy
G½
24
110, 230
1
2
3
1,200
2,300
4,500
G¼
Gy
G½
12, 24, 42
24, 42, 48,
110, 230, 240
Double solenoid valve with dominant signal
JMFDH
1
2
3
1,200
2,300
4,500
G¼
Gy
G½
12, 24, 42
24, 42, 48,
110, 230, 240
Double solenoid valve
JMDH
6,000
G¾
24
42, 110, 230
Double solenoid valve with dominant signal at 14
JMN1DH
1
2
3
Double solenoid valve
JMFH
2
Operating voltage
4
Internet: www.festo.com/catalogue/...
Subject to change – 2013/01
Solenoid valves, ISO 5599-1
Product range overview
Type
Solenoid valve
MN1H
Pilot air supply
internal
Type of reset
pneumatic
spring
external
Page/Internet
mechanical
spring
–
–
Solenoid valve with central plug M12x1
MEBH-…-ZSR
–
–
–
41
30
–
–
–
–
–
–
22
–
–
–
–
–
–
22
–
–
–
–
–
–
34
–
–
–
–
–
–
–
–
–
34
–
–
–
–
–
–
–
–
–
68
MFH
Solenoid valve with single plug M12x1, connector pin allocation to VDMA or Desina
MDH
–
–
Double solenoid valve with dominant signal at 14
JMN1DH
Double solenoid valve
JMFH
Double solenoid valve with dominant signal at 14
JMFDH
Double solenoid valve
JMDH
2013/01 – Subject to change
30
65
MDH
Double solenoid valve
JMN1H
18
Internet: www.festo.com/catalogue/...
3
Solenoid valves, ISO 5599-1
Product range overview
Function
Version
Type
ISO size
Nominal flow
rate
[l/min]
Pneumatic working
port on sub-base
5/2-way valves,
double solenoid
Double solenoid valve with central plug M12x1
JMEBH
1
2
3
1,200
2,300
4,500
Double solenoid valve with central plug M12x1, dominant signal at 14
JMEBDH
1
1,200
2
2,300
3
4,500
Operating voltage
[V DC]
[V AC]
G¼
Gy
G½
24 V DC
–
G¼
Gy
G½
24 V DC
–
24 V DC
–
Double solenoid valve with single plug M12x1, connector pin allocation to VDMA or Desina
JMDH
1
1,200
G¼
2
2,300
Gy
3
4,500
G½
Double solenoid valve with single plug M12x1, connector pin allocation to VDMA or Desina, dominant signal at 14
JMDDH
1
1,200
G¼
24 V DC
2
2,300
Gy
3
4,000
G½
Function
Version
5/3-way valves
Solenoid valve
Type
ISO size
Nominal flow
rate
[l/min]
Pneumatic working
port on sub-base
Operating voltage
[V DC]
[V AC]
MN1H-5/3…
1
2
3
1,200
2,300
4,100
G¼
Gy
G½
24
110, 230
MFH-5/3…
1
2
3
1,200
2,300
4,100
G¼
Gy
G½
12, 24, 42
24, 42, 48,
110, 230, 240
MDH-5/3…
4
6,000
G¾
24
110, 230
1
2
3
1,200
2,300
4,100
G¼
Gy
G½
24
–
24
–
Solenoid valve with central plug M12x1
MEBH-5/3-…-…-ZSR
Solenoid valve with single plug M12x1, connector pin allocation to VDMA or Desina
MDH-5/3…
1
1,200
G¼
2
2,300
Gy
3
4,000 …4,600
G½
4
–
Internet: www.festo.com/catalogue/...
Subject to change – 2013/01
Solenoid valves, ISO 5599-1
Product range overview
Type
Pilot air supply
internal
Double solenoid valve with central plug M12x1
JMEBH
Page/Internet
Type of reset
pneumatic spring
external
mechanical spring
–
–
–
–
–
–
–
–
–
45
Double solenoid valve with central plug M12x1, with dominant signal
JMEBDH
–
–
–
–
–
–
–
–
–
45
Double solenoid valve with single plug M12x1, connector pin allocation to VDMA or Desina
JMDH
–
–
–
–
–
–
–
–
–
34
–
–
–
34
Double solenoid valve with single plug M12x1, connector pin allocation to VDMA or Desina, dominant signal at 14
JMDDH
–
–
–
–
–
–
Type
Solenoid valve
MN1H-5/3…
Pilot air supply
internal
Mid position
closed
external
Page/Internet
exhausting
pressurised
26
MFH-5/3…
37
MDH-5/3…
–
–
71
–
–
–
49
Solenoid valve with single plug M12x1, connector pin allocation to VDMA or Desina
MDH-5/3…
–
–
–
37
Solenoid valve with central plug M12x1
MEBH-5/3-…-…-ZSR
2013/01 – Subject to change
Internet: www.festo.com/catalogue/...
5
Pneumatic valves, ISO 5599-1
Product range overview
Function
5/2-way valves
Version
Type
Pneumatic valve, single pilot
VL
Pneumatic double pilot valve
J
ISO size
Pneumatic
working port on
sub-base
1
2
3
4
1,200
2,300
4,500
6,000
G¼
Gy
G½
G¾
78
1
2
3
4
1,200
2,300
4,500
6,000
G¼
Gy
G½
G¾
–
–
–
–
–
–
–
–
82
G¼
Gy
G½
–
–
–
–
–
–
82
Pneumatic double pilot valve with dominant signal at 14
JD
1
1,200
2
2,300
3
4,500
Function
Version
5/3-way valves
Pneumatic valve
6
Page/Internet
Nominal flow
rate
[l/min]
Type
ISO size
Nominal flow
rate
[l/min]
Pneumatic
working port on
sub-base
VL5/3…
1
2
3
4
1,200
2,300
4,100
4,800
G¼
Gy
G½
G¾
Internet: www.festo.com/catalogue/...
Type of reset
pneumatic
spring
mechanical
spring
Mid position
closed
exhausted pressurised
Page/Internet
85
Subject to change – 2013/01
Solenoid valves, ISO 5599-1
Type codes for valves with square plug
MN1H
—
5/3
G
—
D-1
—
—
—
—
C
Type
MN1H
MFH
MDH
MEBH
JMN1H
JMN1DH
JMFH
JMFDH
JMDH
Single pilot, for N1 solenoid coil
Single solenoid, for F solenoid coil
Single solenoid, with D solenoid coil
Single solenoid, with EB solenoid coil
Double solenoid, for N1 solenoid coil
Double solenoid, for N1 solenoid coil,
with dominant signal at 14
Double solenoid, for F solenoid coil
Double solenoid, for F solenoid coil,
with dominant signal at 14
Double solenoid, with D solenoid coil
Valve function
5/2
5/3
5/2-way valve
5/3-way valve
Mid position
G
E
B
closed
exhausted
pressurised
Size
D-1
D-2
D-3
¾-D-4
ISO size 1
ISO size 2
ISO size 3
ISO size 4
Electrical connection, operating voltage
Plug, square design to EN 175301-803, type A
24DC
24 V DC
Pilot air supply
S
internal
external
Type of reset
FR
Mechanical spring
Pneumatic spring
Generation
C
Series C
2013/01 – Subject to change
Internet: www.festo.com/catalogue/...
7
Solenoid valves, ISO 5599-1
Type codes for valves with round plug
MDH
—
5/3
G
—
D-1
—
—
—
—
—
C
Type
MDH
MEBH
JMDH
JMDDH
JMEBH
JMEBDH
Single solenoid, with D solenoid coil
Single solenoid, with EB solenoid coil
Double solenoid, for D solenoid coil
Double solenoid, for D solenoid coil,
with dominant signal at 14
Double solenoid, with EB solenoid coil
Double solenoid, with EB solenoid coil,
with dominant signal at 14
Valve function
5/2
5/3
5/2-way valve
5/3-way valve
Mid position
G
E
B
closed
exhausted
pressurised
Size
D-1
D-2
D-3
ISO size 1
ISO size 2
ISO size 3
Electrical connection, operating voltage
Central plug, round design, M12x1
ZSR
24 V DC
Individual plug, round design, M12x1
M12
24 V DC
Pin allocation
D
2-pin to VDMA
4-pin to Desina
Pilot air supply
S
internal
external
Type of reset
FR
Mechanical spring
Pneumatic spring
Generation
C
8
Series C
Internet: www.festo.com/catalogue/...
Subject to change – 2013/01
Solenoid valves, ISO 5599-1
Peripherals overview
Port pattern on sub-base to ISO 5599-1
Defined interfaces between valve and sub-base
ISO 1
ISO 2
ISO 3
ISO 4
aD
5
4
1
2
3
aB
Sub-base port designations
Solenoid valves
Pneumatic valves
Signal input 14
aD
Control section
External pilot air supply for pilot valve 14
5
Power section
Valve exhaust port 5
4
Power section
Working port 4
1
Power section
www.festo.com
Working air supply port 1
2
Power section
Working port 2
3
Power section
Valve exhaust port 3
aB
Control section
External pilot air supply for pilot valve 12
2013/01 – Subject to change
Signal input 12
Internet: www.festo.com/catalogue/...
9
Solenoid valves, ISO 5599-1
Peripherals overview
Individual mounting with square plug
6
6
5
5
4
7
1
2
3
1
3
Variants
MN1H-5/2
MFH-5/2
MDH-5/2-D-4
JMN1H-5/2, MN1H-5/3
JMFH-5/2, MFH-5/3
JMDH-5/2-D-4, MDH-5/3-D-4
10
Internet: www.festo.com/catalogue/...
Subject to change – 2013/01
Solenoid valves, ISO 5599-1
Peripherals overview
Accessories
1
2
3
4
5
6
7
Push-in fitting
QS
Individual sub-base
NAS
Silencers
Manual override tool
AHB
Illuminating seal
M…-LD
Plug sockets with/without cables
MSSD, KMF, KMC
Solenoid valve
2013/01 – Subject to change
Brief description
Page/Internet
For connecting compressed air tubing with standard O.D.
quick star
With lateral ports
88
For fitting in exhaust ports
u
101
For indicating the switching status
101
100
Port pattern to ISO 5599-1, corresponding solenoid coils 99
Internet: www.festo.com/catalogue/...
2
11
Solenoid valves, ISO 5599-1
Peripherals overview
Individual mounting with round plug
4
4
4
5
1
2
2
1
3
3
Variants
MDH-5/2
12
JMDH-5/2, MDH-5/3
Internet: www.festo.com/catalogue/...
MEBH-5/2
JMEBH-5/2, MEBH-5/3
Subject to change – 2013/01
Solenoid valves, ISO 5599-1
Peripherals overview
Accessories
1
2
3
4
5
Push-in fitting
QS
Individual sub-base
NAS
Silencers
Plug sockets with/without cables
SAE, KM
Solenoid valve
2013/01 – Subject to change
Brief description
Page/Internet
For connecting compressed air tubing with standard O.D.
quick star
With lateral ports
88
For fitting in exhaust ports
u
101
Port pattern to ISO 5599-1
41
Internet: www.festo.com/catalogue/...
13
Solenoid valves, ISO 5599-1
Peripherals overview
Manifold mounting with square plug
9
aB
8
aA
9
2
8
aJ
7
1
9
2
3
4
5
8
2
6
4
1
8
Variants
MN1H-5/2
MFH-5/2
MDH-5/2-D-4
JMN1H-5/2, MN1H-5/3
JMFH-5/2, MFH-5/3
JMDH-5/2-D-4, MDH-5/3-D-4
14
Internet: www.festo.com/catalogue/...
2
Subject to change – 2013/01
Solenoid valves, ISO 5599-1
Peripherals overview
Accessories
Remarks
Page/Internet
For sealing the manifold sub-bases
91
For connecting compressed air tubing with standard O.D.
quick star
For routing ports 2 and 4 to the front
90
With ports 2 and 4 underneath
90
For sealing the common lines 1, 3, 5 between end plates and manifold sub-bases or between
2 manifold sub-bases, e.g. for different working pressures
For connecting manifold sub-bases of different sizes
92
With ports 2 and 4 either underneath or to the front
91
8
End plate kit
NEV
Push-in fitting
QS
Angle connection block
NAW
Manifold sub-base
NAV
Isolating disc
NSC
Intermediate plate
NZV
Manifold sub-base for angle connection
NAVW
Silencers
For fitting in exhaust ports
u
9
Solenoid valve
Port pattern to ISO 5599-1, corresponding solenoid coils 99
2
aJ
Blanking plate
NDV
Throttle plate
GRO
For sealing unused manifold sub-bases
92
For ISO size 1, 2 and 3 with integrated exhaust air restrictors at ports 3 and 5.
The throttle plate is mounted between the valve and the individual sub-base/manifold
sub-base
For ISO size 1, 2 and 3 for regulating the pressure from 0 to 10 bar according to the supply
pressure. The intermediate pressure regulator plate is mounted between the valve and the
individual sub-base/manifold sub-base
95
1
2
3
4
5
6
7
aA
aB
Intermediate pressure regulator plate
LR-ZP
2013/01 – Subject to change
Internet: www.festo.com/catalogue/...
94
96
15
Solenoid valves, ISO 5599-1
Peripherals overview
Manifold mounting with round plugs
9
aB
9
aA
2
8
2
8
1
7
aJ
9
4
5
6
2
4
3
1
2
8
Variants
MDH-5/2
16
JMDH-5/2, MDH-5/3
Internet: www.festo.com/catalogue/...
MEBH-5/2
8
JMEBH-5/2, MEBH-5/3
Subject to change – 2013/01
Solenoid valves, ISO 5599-1
Peripherals overview
Accessories
Remarks
Page/Internet
For sealing the manifold sub-bases
nev
For connecting compressed air tubing with standard O.D.
quick star
For routing ports 2 and 4 to the front
90
With ports 2 and 4 underneath
90
For sealing the common lines 1, 3, 5 between end plates and manifold sub-bases or between
2 manifold sub-bases, e.g. for different working pressures
For connecting manifold sub-bases of different sizes
92
With ports 2 and 4 either underneath or to the front
91
8
End plate kit
NEV
Push-in fitting
QS
Angle connection block
NAW
Manifold sub-base
NAV
Isolating disc
NSC
Intermediate plate
NZV
Manifold sub-base for angle connection
NAVW
Silencers
For fitting in exhaust ports
u
9
Solenoid valve
Port pattern to ISO 5599-1
2
aJ
Blanking plate
NDV
Throttle plate
GRO
For sealing unused manifold sub-bases
92
For ISO size 1, 2 and 3 with integrated exhaust air restrictors at ports 3 and 5.
The throttle plate is mounted between the valve and the individual sub-base/manifold
sub-base
For ISO size 1, 2 and 3 for regulating the pressure from 0 to 10 bar according to the supply
pressure. The intermediate pressure regulator plate is mounted between the valve and the
individual sub-base/manifold sub-base
95
1
2
3
4
5
6
7
aA
aB
Intermediate pressure regulator plate
LR-ZP
2013/01 – Subject to change
Internet: www.festo.com/catalogue/...
94
96
17
Solenoid valves MN1H, ISO 5599-1
Technical data – 5/2-way valves
-M-P-
Flow rate
1200 … 4500 l/min
Voltage
24 V DC
110, 230 V AC
General technical data
ISO size
1
Valve function
Constructional design
Sealing principle
Actuation type
Type of reset
Type of pilot control
Pilot air supply
Direction of flow
Exhaust function
Manual override
Type of mounting
Mounting position
Nominal size
Standard nominal flow rate
Grid dimension
Pneumatic connection on sub-base
Product weight
Noise level
Certification
5/2-way, single solenoid
Piston spool
Soft
Electrical
Mechanical or pneumatic spring
Piloted
Internal or external
Non-reversible
With flow control
Via accessory, detenting
Via through-holes
Any
8
11
1200
2300
43
56
G¼
Gy
450
710
85
Germanischer Lloyd
[mm]
[l/min]
[mm]
[g]
[dB (A)]
Operating and environmental conditions
Type of reset
3
14.5
4500
71
G½
1000
Pneumatic
Operating medium
Pilot medium
Note on operating/pilot medium
Operating pressure
2
Internal pilot air supply
External pilot air supply
Pilot pressure
Ambient temperature
Temperature of medium
[bar]
[bar]
[bar]
[°C]
[°C]
Mechanical
Compressed air in accordance with ISO 8573-1:2010 [7:4:4]
Compressed air in accordance with ISO 8573-1:2010 [7:4:4]
Operation with lubricated medium possible (in which case lubricated operation will
always be required)
2 … 10
3 … 10
–0.9 … +16
–0.9 … +16
2 … 10
3 … 10
–10 … +50
–10 … +50
*
Valve response times [ms]
ISO size
1
Type of reset
Pneumatic
Mechanical
2
Pneumatic
Mechanical
3
Pneumatic
Mechanical
On
Off
17
39
46
69
24
62
49
71
33
74
18
23
32
Internet: www.festo.com/catalogue/...
Subject to change – 2013/01
Solenoid valves MN1H, ISO 5599-1
Technical data – 5/2-way valves
Electrical data
N1 solenoid coil
Electrical connection
Operating voltage
Coil characteristics
D.C. voltage
A.C. voltage
D.C. voltage
A.C. voltage
[V DC]
[V AC]
[W]
[VA]
Protection class to EN 60 529
Plug, square design to EN 175301-803, type A
24
110/230 (50 … 60 Hz)
2.5
Pull: 7.5
Hold: 5
IP65
Materials
Sectional view
1
1
–
Housing
Seals
2013/01 – Subject to change
Die-cast aluminium, polyacetate
Nitrile rubber
Internet: www.festo.com/catalogue/...
19
Solenoid valves MN1H, ISO 5599-1
Technical data – 5/2-way valves
Download CAD data www.festo.com
Dimensions
2 Manual override
3 Captive mounting screws
4 Slot for inscription label
Type
B1
B2
B3
B4
D1
H1
H2
H3
H4
H5
L1
L2
L3
L4
L5
L6
ISO size 1
MN1H-5/2-…
MN1H-5/2-…-FR
42
28
6
30
M5
106
74
38
9
46.5
117.5
128
87.6
98
43.8
36
18
89
ISO size 2
MN1H-5/2-…
MN1H-5/2-…-FR
54
38
9
30
M6
116
84
48
9.5
56.5
147.6
161.5
123.4
140.7
61.7
48
24
98
ISO size 3
MN1H-5/2-…
MN1H-5/2-…-FR
65
48
12
30
M8
123
91
55
12
63.5
169
184.8
145.4
164.7
72.7
64
32
109
20
Internet: www.festo.com/catalogue/...
Subject to change – 2013/01
Solenoid valves MN1H, ISO 5599-1
Technical data – 5/2-way valves
Ordering data
Circuit symbol
1)
Description
ISO size
Part No.
Type
Without N1 solenoid coil1),
internal pilot air supply,
pneumatic reset
1
2
3
159688
159700
159712
MN1H-5/2-D-1-C
MN1H-5/2-D-2-C
MN1H-5/2-D-3-C
Without N1 solenoid coil1),
external pilot air supply,
pneumatic reset
1
2
3
159686
159698
159710
MN1H-5/2-D-1-S-C
MN1H-5/2-D-2-S-C
MN1H-5/2 D-3-S-C
Without N1 solenoid coil1),
internal pilot air supply,
mechanical reset
1
2
3
159687
159699
159711
MN1H-5/2-D-1-FR-C
MN1H-5/2-D-2-FR-C
MN1H-5/2-D-3-FR-C
Without N1 solenoid coil1),
external pilot air supply,
mechanical reset
1
2
3
159716
159718
160896
MN1H-5/2-D-1-FR-S-C
MN1H-5/2-D-2-FR-S-C
MN1H-5/2-D-3-FR-S-C
N1 solenoid coils 99
2013/01 – Subject to change
Internet: www.festo.com/catalogue/...
21
Solenoid valves JMN1H, ISO 5599-1
Technical data – 5/2-way valves, double solenoid
-M-P-
Flow rate
1200 … 4500 l/min
Voltage
24 V DC
110, 230, 240 V AC
General technical data
ISO size
1
Valve function
Constructional design
Sealing principle
Actuation type
Type of reset
Type of pilot control
Pilot air supply
Direction of flow
Exhaust function
Manual override
Type of mounting
Mounting position
Nominal size
Standard nominal flow rate
Grid dimension
Pneumatic connection on sub-base
Product weight
Noise level
Certification
5/2-way, double solenoid
Piston spool
Soft
Electrical
Mechanical spring
Piloted
Internal or external
Non-reversible
With flow control
Via accessory, detenting
Via through-holes
Any
8
1200
43
G¼
610
85
Germanischer Lloyd
[mm]
[l/min]
[mm]
[g]
[dB (A)]
2
3
11
2300
56
Gy
880
14.5
4500
71
G½
1090
Operating and environmental conditions
Operating medium
Pilot medium
Note on operating/pilot medium
Operating pressure
Internal pilot air supply
External pilot air supply
Pilot pressure
Ambient temperature
Temperature of medium
[bar]
[bar]
[bar]
[°C]
[°C]
Compressed air in accordance with ISO 8573-1:2010 [7:4:4]
Compressed air in accordance with ISO 8573-1:2010 [7:4:4]
Operation with lubricated medium possible (in which case lubricated operation will
always be required)
2 … 10
–0.9 … +16
2 … 10
–10 … +50
–10 … +50
*
Valve response times
ISO size
1
2
Dominant signal at
14
18
22
12: 18 ms;
14: 15 ms
3
Dominant signal at
14
21
Internet: www.festo.com/catalogue/...
12: 24 ms;
14: 21 ms
Dominant signal at
14
21
12: 24 ms;
14: 21 ms
Subject to change – 2013/01
Solenoid valves JMN1H, ISO 5599-1
Technical data – 5/2-way valves, double solenoid
Electrical data
N1 solenoid coil
Electrical connection
Operating voltage
Coil characteristics
D.C. voltage
A.C. voltage
D.C. voltage
A.C. voltage
[V DC]
[V AC]
[W]
[VA]
Protection class to EN 60 529
Plug, square design to EN 175301-803, type A
24
110/230 (50 … 60 Hz)
2.5
Pull: 7.5
Hold: 5
IP65
Materials
Sectional view
1
1
–
Housing
Seals
2013/01 – Subject to change
Die-cast aluminium, polyacetate
Nitrile rubber
Internet: www.festo.com/catalogue/...
23
Solenoid valves JMN1H, ISO 5599-1
Technical data – 5/2-way valves, double solenoid
Download CAD data www.festo.com
Dimensions
2 Manual override
3 Captive mounting screws
4 Slot for inscription label
ISO size
B1
B2
B3
B4
D1
H1
H2
H3
H4
L1
L2
L3
L4
L5
L6
1
2
3
42
54
65
28
38
48
6
9
12
30
30
30
M5
M6
M8
106
116
123
74
84
91
38
48
55
9
9.5
12
147.3
165
185.7
87.6
123.4
145.4
43.8
61.7
72.7
36
48
64
18
24
32
89
98
109
24
Internet: www.festo.com/catalogue/...
Subject to change – 2013/01
Solenoid valves JMN1H, ISO 5599-1
Technical data – 5/2-way valves, double solenoid
Ordering data – Double solenoid valve
Circuit symbol
1)
Description
ISO size
Part No.
Type
Without N1 solenoid coil1),
internal pilot air supply
1
2
3
159690
159702
159714
JMN1H-5/2-D-1-C
JMN1H-5/2-D-2-C
JMN1H-5/2-D-3-C
Without N1 solenoid coil1),
external pilot air supply
1
2
3
159689
159701
159713
JMN1H-5/2-D-1-S-C
JMN1H-5/2-D-2-S-C
JMN1H-5/2 D-3-S-C
Without N1 solenoid coil1),
internal pilot air supply,
with dominant signal at 14
1
2
3
159691
159703
159715
JMN1DH-5/2-D-1-C
JMN1DH-5/2-D-2-C
JMN1DH-5/2-D-3-C
Without N1 solenoid coil1),
external pilot air supply,
with dominant signal at 14
1
2
3
159717
159719
160897
JMN1DH-5/2-D-1-S-C
JMN1DH-5/2-D-2-S-C
JMN1DH-5/2-D-3-S-C
N1 solenoid coils 99
2013/01 – Subject to change
Internet: www.festo.com/catalogue/...
25
Solenoid valves MN1H, ISO 5599-1
Technical data – 5/3-way valves
-M-P-
Flow rate
1200 … 4600 l/min
Voltage
24 V DC
110, 230 V AC
General technical data
ISO size
1
2
3
Valve function
Constructional design
Sealing principle
Actuation type
Type of reset
Type of pilot control
Pilot air supply
Direction of flow
Exhaust function
Manual override
Type of mounting
Mounting position
Nominal size
Standard nominal flow rate
5/3-way, double solenoid
Piston spool
Soft
Electrical
Mechanical spring
Piloted
Internal
Non-reversible
With flow control
Via accessory, detenting
Via through-holes
Any
8
1200
11
2300
14.5
4100
4600
4000
71
G½
1170
Closed
Exhausted
Pressurised
Grid dimension
Pneumatic connection on sub-base
Product weight
Noise level
Certification
[mm]
[l/min]
[l/min]
[l/min]
[mm]
[g]
[dB (A)]
43
G¼
650
85
Germanischer Lloyd
56
Gy
940
Operating and environmental conditions
Operating medium
Pilot medium
Note on operating/pilot medium
Operating pressure
Internal pilot air supply
External pilot air supply
Pilot pressure
Ambient temperature
Temperature of medium
[bar]
[bar]
[bar]
[°C]
[°C]
Compressed air in accordance with ISO 8573-1:2010 [7:4:4]
Compressed air in accordance with ISO 8573-1:2010 [7:4:4]
Operation with lubricated medium possible (in which case lubricated operation will
always be required)
3 … 10
–0.9 … +16
3 … 10
–10 … +50
–10 … +50
*
Valve response times [ms]
ISO size
1
On
Off
2
On
Off
3
On
Off
With N1 solenoid coil
Closed
20
Exhausted
20
Pressurised
20
44
46
46
33
36
35
82
84
78
33
36
35
82
84
78
26
Internet: www.festo.com/catalogue/...
Subject to change – 2013/01
Solenoid valves MN1H, ISO 5599-1
Technical data – 5/3-way valves
Electrical data
N1 solenoid coil
Electrical connection
Operating voltage
Coil characteristics
D.C. voltage
A.C. voltage
D.C. voltage
A.C. voltage
[V DC]
[V AC]
[W]
[VA]
Protection class to EN 60 529
Plug, square design to EN 175301-803, type A
24
110/230 (50 … 60 Hz)
2.5
Pull: 7.5
Hold: 5
IP65
Materials
Sectional view
1
1
–
Housing
Seals
2013/01 – Subject to change
Die-cast aluminium, polyacetate
Nitrile rubber
Internet: www.festo.com/catalogue/...
27
Solenoid valves MN1H, ISO 5599-1
Technical data – 5/3-way valves
Download CAD data www.festo.com
Dimensions
2 Manual override
3 Captive mounting screws
4 Slot for inscription label
ISO size
B1
B2
B3
B4
D1
H1
H2
H3
H4
L1
L2
L3
L4
L5
L6
1
2
3
42
54
65
28
38
48
6
9
12
30
30
30
M5
M6
M8
106
116
123
74
84
91
38
48
55
9
9.5
12
147.3
165
185.7
108.4
158
184
54.2
79
92
36
48
64
18
24
32
89
98
109
28
Internet: www.festo.com/catalogue/...
Subject to change – 2013/01
Solenoid valves MN1H, ISO 5599-1
Technical data – 5/3-way valves
Ordering data
Circuit symbol
1)
Description
ISO size
Part No.
Type
Without N1 solenoid coil1),
normally closed,
internal pilot air supply
1
2
3
159681
159693
159705
MN1H-5/3G-D-1-C
MN1H-5/3G-D-2-C
MN1H-5/3G-D-3-C
Without N1 solenoid coil1),
normally closed,
external pilot air supply
1
2
3
159680
159692
159704
MN1H-5/3G-D-1-S-C
MN1H-5/3G-D-2-S-C
MN1H-5/3G D-3-S-C
Without N1 solenoid coil1),
normally exhausted,
internal pilot air supply
1
2
3
159683
159695
159707
MN1H-5/3E-D-1-C
MN1H-5/3E-D-2-C
MN1H-5/3E-D-3-C
Without N1 solenoid coil1),
normally exhausted,
external pilot air supply
1
2
3
159682
159694
159706
MN1H-5/3E-D-1-S-C
MN1H-5/3E-D-2-S-C
MN1H-5/3E-D-3-S-C
Without N1 solenoid coil1),
normally pressurised,
internal pilot air supply
1
2
3
159685
159697
159709
MN1H-5/3B-D-1-C
MN1H-5/3B-D-2-C
MN1H-5/3B-D-3-C
Without N1 solenoid coil1),
normally pressurised,
external pilot air supply
1
2
3
159684
159696
159708
MN1H-5/3B-D-1-S-C
MN1H-5/3B-D-2-S-C
MN1H-5/3B-D-3-S-C
N1 solenoid coils 99
2013/01 – Subject to change
Internet: www.festo.com/catalogue/...
29
Solenoid valves MFH, ISO 5599-1
Technical data – 5/2-way valves
-M-P-
Flow rate
1200 … 4500 l/min
Voltage
12, 24, 42, 48 V DC
24, 42, 48, 110, 230,
240 V AC
General technical data
ISO size
1
Valve function
Constructional design
Sealing principle
Actuation type
Type of reset
Type of pilot control
Pilot air supply
Direction of flow
Exhaust function
Manual override
Type of mounting
Mounting position
Nominal size
Standard nominal flow rate
Grid dimension
Pneumatic connection on sub-base
Product weight
Noise level
Certification
5/2-way, single solenoid
Piston spool
Soft
Electrical
Mechanical or pneumatic spring
Piloted
Internal
Non-reversible
With flow control
Via accessory, detenting
Via through-holes
Any
8
11
1200
2300
43
56
G¼
Gy
390
650
85
Germanischer Lloyd
[mm]
[l/min]
[mm]
[g]
[dB (A)]
Operating and environmental conditions
Type of reset
3
14.5
4500
71
G½
960
Pneumatic
Operating medium
Pilot medium
Note on operating/pilot medium
Operating pressure
2
Internal pilot air supply
External pilot air supply
Pilot pressure
Ambient temperature
Temperature of medium
[bar]
[bar]
[bar]
[°C]
[°C]
Mechanical
Compressed air in accordance with ISO 8573-1:2010 [7:4:4]
Compressed air in accordance with ISO 8573-1:2010 [7:4:4]
Operation with lubricated medium possible (in which case lubricated operation will
always be required)
2 … 10
3 … 10
–0.9 … +16
–0.9 … +16
2 … 10
3 … 10
–5 … +40
–10 … +60
*
Valve response times [ms]
ISO size
1
Type of reset
Pneumatic
Mechanical
2
Pneumatic
Mechanical
3
Pneumatic
Mechanical
With F solenoid coil
On
Off
16
45
48
71
27
73
60
66
30
82
30
23
35
Internet: www.festo.com/catalogue/...
Subject to change – 2013/01
Solenoid valves MFH, ISO 5599-1
Technical data – 5/2-way valves
Electrical data
F solenoid coil
Electrical connection
Operating voltage
Coil characteristics
Design
D.C. voltage
A.C. voltage
D.C. voltage
A.C. voltage
[V DC]
[V AC]
[W]
[VA]
Protection class to EN 60 529
Plug vanes for plug sockets MSSD-F, KMF
12, 24, 42, 48
24, 42, 48, 110, 230, 240 (50 … 60 Hz)
4.5
Pull: 7.5
Hold: 6
IP65
Materials
Sectional view
1
1
–
Housing
Seals
2013/01 – Subject to change
Die-cast aluminium, polyacetate
Nitrile rubber
Internet: www.festo.com/catalogue/...
31
Solenoid valves MFH, ISO 5599-1
Technical data – 5/2-way valves
Download CAD data www.festo.com
Dimensions
2 Manual override
3 Captive mounting screws
4 Slot for inscription label
Type
B1
B2
B3
B4
D1
H1
H2
H3
H4
H5
L1
L2
L3
L4
L5
L6
ISO size 1
MFH-5/2-…
MFH-5/2-…-FR
42
28
6
30
M5
100
70.3
38
9
46.5
115
125.6
87.6
98
43.8
36
18
89
ISO size 2
MFH-5/2-…
MFH-5/2-…-FR
54
38
9
30
M6
110
80.3
48
9.5
56.5
142
159.4
123.4
140.7
61.7
48
24
98
ISO size 3
MFH-5/2-…
MFH-5/2-…-FR
65
48
12
30
M8
117
87.3
55
12
63.5
163
182
145.4
164.7
72.7
64
32
109
32
Internet: www.festo.com/catalogue/...
Subject to change – 2013/01
Solenoid valves MFH, ISO 5599-1
Technical data – 5/2-way valves
Ordering data
Circuit symbol
1)
Description
ISO size
Part No.
Type
Without F solenoid coil1),
pneumatic reset,
internal pilot air supply
1
2
3
150981
151851
151870
MFH-5/2-D-1-C
MFH-5/2-D-2-C
MFH-5/2-D-3-C
Without F solenoid coil1),
pneumatic reset,
external pilot air supply
1
2
3
152562
151022
151032
MFH-5/2-D-1-S-C
MFH-5/2-D-2-S-C
MFH-5/2-D-3-S-C
Without F solenoid coil1),
mechanical reset,
internal pilot air supply
1
2
3
151016
151709
151711
MFH-5/2-D-1-FR-C
MFH-5/2-D-2-FR-C
MFH-5/2-D-3-FR-C
F solenoid coils 99
2013/01 – Subject to change
Internet: www.festo.com/catalogue/...
33
Solenoid valves JMFH, ISO 5599-1
Technical data – 5/2-way valves, double solenoid
-M-P-
Flow rate
1200 … 4500 l/min
Voltage
12, 24, 42, 48 V DC
24, 42, 48, 110, 230,
240 V AC
General technical data
ISO size
1
Valve function
Constructional design
Sealing principle
Actuation type
Type of pilot control
Pilot air supply
Direction of flow
Exhaust function
Manual override
Type of mounting
Mounting position
Nominal size
Standard nominal flow rate
Grid dimension
Pneumatic connection on sub-base
Product weight
Noise level
Certification
5/2-way, double solenoid
Piston spool
Soft
Electrical
Piloted
Internal or external
Non-reversible
With flow control
Via accessory, detenting
Via through-holes
Any
8
1200
43
G¼
490
85
Germanischer Lloyd
[mm]
[l/min]
[mm]
[g]
[dB (A)]
2
3
11
2300
56
Gy
750
14.5
4500
71
G½
1060
Operating and environmental conditions
Operating medium
Pilot medium
Note on operating/pilot medium
Operating pressure
Internal pilot air supply
External pilot air supply
Pilot pressure
Ambient temperature
Temperature of medium
[bar]
[bar]
[bar]
[°C]
[°C]
Compressed air in accordance with ISO 8573-1:2010 [7:4:4]
Compressed air in accordance with ISO 8573-1:2010 [7:4:4]
Operation with lubricated medium possible (in which case lubricated operation will
always be required)
2 … 10
–0.9 … +16
2 … 10
–5 … +40
–10 … +60
*
Valve response times [ms]
ISO size
1
2
Dominant signal at
14
3
Dominant signal at
14
Dominant signal at
14
With F solenoid coil
16
34
16
18
Internet: www.festo.com/catalogue/...
18
18
18
Subject to change – 2013/01
Solenoid valves JMFH, ISO 5599-1
Technical data – 5/2-way valves, double solenoid
Electrical data
ISO size
F solenoid coil
Electrical connection
Operating voltage
Coil characteristics
1, 2, 3
Design
D.C. voltage
A.C. voltage
D.C. voltage
A.C. voltage
[V DC]
[V AC]
[W]
[VA]
Protection class to EN 60 529
Plug vanes for plug sockets MSSD-F, KMF
12, 24, 42, 48
24, 42, 48, 110, 230, 240 (50 … 60 Hz)
4.5
Pull: 7.5
Hold: 6
IP65
Materials
Sectional view
1
1
–
Housing
Seals
2013/01 – Subject to change
Die-cast aluminium, polyacetate
Nitrile rubber
Internet: www.festo.com/catalogue/...
35
Solenoid valves JMFH, ISO 5599-1
Technical data – 5/2-way valves, double solenoid
Download CAD data www.festo.com
Dimensions
2 Manual override
3 Captive mounting screws
4 Slot for inscription label
ISO size
B1
B2
B3
B4
D1
H1
H2
H3
H4
L1
L2
L3
L4
L5
L6
1
2
3
42
54
65
28
38
48
6
9
12
30
30
30
M5
M6
M8
100
110
117
70.3
80.3
87.3
38
48
55
9
9.5
12
142.6
160.4
181
87.6
123.4
145.4
43.8
61.7
72.7
36
48
64
18
24
32
88
97
109
Ordering data
Circuit symbol
Description
ISO size
Part No.
Type
Without F solenoid coil1),
1
2
3
150980
151852
151871
JMFH-5/2-D-1-C
JMFH-5/2-D-2-C
JMFH-5/2-D-3-C
Without F solenoid coil1),
external pilot air supply
1
2
3
152563
151023
151033
JMFH-5/2-D-1-S-C
JMFH-5/2-D-2-S-C
JMFH-5/2-D-3-S-C
Without F solenoid coil1),
internal pilot air supply,
with dominant signal at 14
1
2
3
151019
151853
151872
JMFDH-5/2-D-1-C
JMFDH-5/2-D-2-C
JMFDH-5/2-D-3-C
internal pilot air supply
1)
36
F solenoid coils 99
Internet: www.festo.com/catalogue/...
Subject to change – 2013/01
Solenoid valves MFH, ISO 5599-1
Technical data – 5/3-way valves
-M-P-
Flow rate
1200 … 4600 l/min
Voltage
12, 24, 42, 48 V DC
24, 42, 48, 110, 230,
240 V AC
General technical data
ISO size
1
2
3
Valve function
Constructional design
Sealing principle
Actuation type
Type of reset
Type of pilot control
Pilot air supply
Direction of flow
Exhaust function
Manual override
Type of mounting
Mounting position
Nominal size
Standard nominal flow rate
5/3-way, double solenoid
Piston spool
Soft
Electrical
Mechanical spring
Piloted
Internal or external
Non-reversible
With flow control
Via accessory, detenting
Via through-holes
Any
8
1200
11
2300
14.5
4100
4600
4000
71
G½
1040
[mm]
[l/min]
[l/min]
[l/min]
[mm]
Closed
Exhausted
Pressurised
Grid dimension
Pneumatic connection on sub-base
Product weight
Noise level
Certification
[g]
[dB (A)]
43
G¼
520
85
Germanischer Lloyd
56
Gy
820
Operating and environmental conditions
Operating medium
Pilot medium
Note on operating/pilot medium
Operating pressure
Internal pilot air supply
External pilot air supply
Pilot pressure
Ambient temperature
Temperature of medium
[bar]
[bar]
[bar]
[°C]
[°C]
Compressed air in accordance with ISO 8573-1:2010 [7:4:4]
Compressed air in accordance with ISO 8573-1:2010 [7:4:4]
Operation with lubricated medium possible (in which case lubricated operation will
always be required)
3 … 10
–0.9 … +16
3 … 10
–5 … +40
–10 … +60
*
Valve response times [ms]
ISO size
1
On
Off
2
On
Off
3
On
Off
With F solenoid coil
Closed
Exhausted
Pressurised
36
36
36
33
35
35
63
67
69
36
37
36
77
78
75
2013/01 – Subject to change
18
18
18
Internet: www.festo.com/catalogue/...
37
Solenoid valves MFH, ISO 5599-1
Technical data – 5/3-way valves
Electrical data
F solenoid coil
Electrical connection
Operating voltage
Coil characteristics
Design
D.C. voltage
A.C. voltage
D.C. voltage
A.C. voltage
[V DC]
[V AC]
[W]
[VA]
Protection class to EN 60 529
Plug vanes for plug sockets MSSD-F, KMF
12, 24, 42, 48
24, 42, 48, 110, 230, 240 (50 … 60 Hz)
4.5
Pull: 7.5
Hold: 6
IP65
Materials
Sectional view
1
1
–
38
Housing
Seals
Die-cast aluminium, polyacetate
Nitrile rubber
Internet: www.festo.com/catalogue/...
Subject to change – 2013/01
Solenoid valves MFH, ISO 5599-1
Technical data – 5/3-way valves
Download CAD data www.festo.com
Dimensions
2 Manual override
3 Captive mounting screws
4 Slot for inscription label
ISO size
B1
B2
B3
B4
D1
H1
H2
H3
H4
L1
L2
L3
L4
L5
L6
1
2
3
42
54
65
28
38
48
6
9
12
30
30
30
M5
M6
M8
100
110
117
70.3
80.3
87.3
38
48
55
9
9.5
12
142.6
160
181
108.4
158
184
54.2
79
92
36
48
64
18
24
32
89
98
109
2013/01 – Subject to change
Internet: www.festo.com/catalogue/...
39
Solenoid valves MFH, ISO 5599-1
Technical data – 5/3-way valves
Ordering data
Circuit symbol
1)
40
Description
ISO size
Part No.
Type
Without F solenoid coil1),
normally closed,
internal pilot air supply
1
2
3
150982
151854
151873
MFH-5/3G-D-1-C
MFH-5/3G-D-2-C
MFH-5/3G-D-3-C
Without F solenoid coil1),
normally closed,
external pilot air supply
1
2
3
152564
151024
151034
MFH-5/3G-D-1-S-C
MFH-5/3G-D-2-S-C
MFH-5/3G-D-3-S-C
Without F solenoid coil1),
normally exhausted,
internal pilot air supply
1
2
3
150983
151855
151874
MFH-5/3E-D-1-C
MFH-5/3E-D-2-C
MFH-5/3E-D-3-C
Without F solenoid coil1),
normally exhausted,
external pilot air supply
1
2
3
152565
151025
151035
MFH-5/3E-D-1-S-C
MFH-5/3E-D-2-S-C
MFH-5/3E-D-3-S-C
Without F solenoid coil1),
normally pressurised,
internal pilot air supply
1
2
3
150984
151856
151875
MFH-5/3B-D-1-C
MFH-5/3B-D-2-C
MFH-5/3B-D-3-C
Without F solenoid coil1),
normally pressurised,
external pilot air supply
1
2
3
152566
151026
151036
MFH-5/3B-D-1-S-C
MFH-5/3B-D-2-S-C
MFH-5/3B-D-3-S-C
F solenoid coils 99
Internet: www.festo.com/catalogue/...
Subject to change – 2013/01
Solenoid valves MEBH, ISO 5599-1
Technical data – 5/2-way valves
-M-P-
Flow rate
1200 … 4500 l/min
Voltage
24 V DC
General technical data
ISO size
1
Valve function
Constructional design
Sealing principle
Actuation type
Type of reset
Type of pilot control
Pilot air supply
Direction of flow
Exhaust function
Manual override
Type of mounting
Mounting position
Nominal size
Standard nominal flow rate
Grid dimension
Pneumatic connection on sub-base
Product weight
Noise level
5/2-way, single solenoid
Piston spool
Soft
Electrical
Mechanical or pneumatic spring
Piloted
Internal
Non-reversible
With flow control
Via accessory, detenting
Via through-holes
Any
8
11
1200
2300
43
56
G¼
Gy
550
700
85
[mm]
[l/min]
[mm]
[g]
[dB (A)]
Operating and environmental conditions
Type of reset
3
14.5
4500
71
G½
1000
Pneumatic
Operating medium
Pilot medium
Note on operating/pilot medium
Operating pressure
2
Internal pilot air supply
External pilot air supply
Pilot pressure
Ambient temperature
Temperature of medium
[bar]
[bar]
[bar]
[°C]
[°C]
Mechanical
Compressed air in accordance with ISO 8573-1:2010 [7:4:4]
Compressed air in accordance with ISO 8573-1:2010 [7:4:4]
Operation with lubricated medium possible (in which case lubricated operation will
always be required)
2 … 10
3 … 10
–0.9 … +16
–0.9 … +16
2 … 10
3 … 10
–5 … +50
–5 … +50
*
Valve response times [ms]
ISO size
1
Type of reset
Pneumatic
Mechanical
2
Pneumatic
Mechanical
3
Pneumatic
Mechanical
With EB solenoid coil
On
20
Off
33
15
50
50
85
33
103
59
87
28
109
2013/01 – Subject to change
Internet: www.festo.com/catalogue/...
41
Solenoid valves MEBH, ISO 5599-1
Technical data – 5/2-way valves
Electrical data
EB solenoid coil
Electrical connection
Operating voltage
Coil characteristics
Protection class to EN 60 529
D.C. voltage
D.C. voltage
[V DC]
[W]
Central plug, round design, M12x1
24
2.5
IP65
Materials
Sectional view
1
1
–
42
Housing
Seals
Die-cast aluminium, polyacetate
Nitrile rubber
Internet: www.festo.com/catalogue/...
Subject to change – 2013/01
Solenoid valves MEBH, ISO 5599-1
Technical data – 5/2-way valves
Download CAD data www.festo.com
Dimensions
1 Attachment of plug socket
adjustable by 3x 30°
2 Manual override
3 Captive mounting screws
5 LED display
6 Angled socket
SEA-M12-4WD-PG7
101
Type
B1
B2
B3
B4
D1
H1
H2
H3
H4
H5
L1
L2
L3
L4
L5
L6
ISO size 1
MEBH-5/2-…
MEBH-5/2-…-FR
42
28
6
17.5
M5
110
80.3
38
9
74.7
110.8
121.3
87.6
98
43.8
36
18
67
ISO size 2
MEBH-5/2-…
MEBH-5/2-…-FR
54
38
9
17.5
M6
120
90.1
48
9.5
84.2
137.6
154.9
123.4
140.7
61.7
48
24
75.9
ISO size 3
MEBH-5/2-…
MEBH-5/2-…-FR
65
48
12
17.5
M8
130
97.8
55
12
93.1
158.7
178
145.4
164.7
72.7
64
32
86
M12 central plug – Terminal allocation
Mono connection
2
1
3
4
2013/01 – Subject to change
1
2
3
4
Unused
Unused
com (–)
Signal (+) Solenoid 14
Internet: www.festo.com/catalogue/...
43
Solenoid valves MEBH, ISO 5599-1
Technical data – 5/2-way valves
Ordering data
Circuit symbol
44
Description
Voltage
ISO size
Part No.
Type
With EB solenoid coil,
with central plug,
pneumatic reset,
internal pilot air supply
24 V DC
1
2
3
184493
184500
184507
MEBH-5/2-D-1-ZSR-C
MEBH-5/2-D-2-ZSR-C
MEBH-5/2-D-3-ZSR-C
With EB solenoid coil,
with central plug,
mechanical reset,
internal pilot air supply
24 V DC
1
2
3
184494
184501
184508
MEBH-5/2-D-1-ZSR-FR-C
MEBH-5/2-D-2-ZSR-FR-C
MEBH-5/2-D-3-ZSR-FR-C
Internet: www.festo.com/catalogue/...
Subject to change – 2013/01
Solenoid valves JMEBH, ISO 5599-1
Technical data – 5/2-way valves, double solenoid
-M-P-
Flow rate
1200 … 4500 l/min
Voltage
24 V DC
General technical data
ISO size
1
Valve function
Constructional design
Sealing principle
Actuation type
Type of pilot control
Pilot air supply
Direction of flow
Exhaust function
Manual override
Type of mounting
Mounting position
Nominal size
Standard nominal flow rate
Grid dimension
Pneumatic connection on sub-base
Product weight
Noise level
[g]
[dB (A)]
5/2-way, double solenoid
Piston spool
Soft
Electrical
Piloted
Internal or external
Non-reversible
With flow control
Via accessory, detenting
Via through-holes
Any
8
1200
43
G¼
600
85
[bar]
[bar]
[bar]
[°C]
[°C]
Compressed air in accordance with ISO 8573-1:2010 [7:4:4]
Compressed air in accordance with ISO 8573-1:2010 [7:4:4]
Operation with lubricated medium possible (in which case lubricated operation will
always be required)
2 … 10
–0.9 … +16
2 … 10
–5 … +50
–5 … +50
[mm]
[l/min]
[mm]
2
3
11
2300
56
Gy
770
14.5
4500
71
G½
1080
Operating and environmental conditions
Operating medium
Pilot medium
Note on operating/pilot medium
Operating pressure
Internal pilot air supply
External pilot air supply
Pilot pressure
Ambient temperature
Temperature of medium
*
Valve response times [ms]
ISO size
1
2
Dominant signal at
14
With EB solenoid coil
Changeover
12
2013/01 – Subject to change
13
3
Dominant signal at
14
15
23
Dominant signal at
14
16
Internet: www.festo.com/catalogue/...
20
45
Solenoid valves JMEBH, ISO 5599-1
Technical data – 5/2-way valves, double solenoid
Electrical data
EB solenoid coil
Electrical connection
Operating voltage
Coil characteristics
Protection class to EN 60 529
Design
D.C. voltage
D.C. voltage
[V DC]
[W]
Central plug, round design, M12x1
24
2.5
IP65
Materials
Sectional view
1
1
–
46
Housing
Seals
Die-cast aluminium, polyacetate
Nitrile rubber
Internet: www.festo.com/catalogue/...
Subject to change – 2013/01
Solenoid valves JMEBH, ISO 5599-1
Technical data – 5/2-way valves, double solenoid
Download CAD data www.festo.com
Dimensions
1 Attachment of plug socket
adjustable by 3x 30°
2 Manual override
3 Captive mounting screws
5 LED display
6 Angled socket
SEA-M12-4WD-PG7
101
ISO size
B1
B2
B3
B4
D1
H1
H2
H3
H4
H5
L1
L2
L3
L4
L5
L6
1
2
3
42
54
65
28
38
48
6
9
12
17.5
17.5
17.5
M5
M6
M8
110
120
130
80.3
90.1
97.8
38
48
55
9
9.5
12
74.7
84.2
93.1
134
151.8
171.9
87.6
123.4
145.4
43.8
61.7
72.7
36
48
64
18
24
32
67
75.9
86
M12 central plug – Terminal allocation
Duo connection
2
1
3
4
2013/01 – Subject to change
1
2
3
4
Unused
Signal (+) Solenoid 12
com (–)
Signal (+) Solenoid 14
Internet: www.festo.com/catalogue/...
47
Solenoid valves JMEBH, ISO 5599-1
Technical data – 5/2-way valves, double solenoid
Ordering data
Circuit symbol
48
Solenoid coil
Voltage
ISO size
Part No.
Type
With EB solenoid coil,
with central plug,
internal pilot air supply
24 V DC
1
2
3
184495
184502
184509
JMEBH-5/2-D-1-ZSR-C
JMEBH-5/2-D-2-ZSR-C
JMEBH-5/2-D-3-ZSR-C
With EB solenoid coil,
with central plug,
internal pilot air supply,
with dominant signal at 14
24 V DC
1
2
3
184496
184503
184510
JMEBDH-5/2-D-1-ZSR-C
JMEBDH-5/2-D-2-ZSR-C
JMEBDH-5/2-D-3-ZSR-C
Internet: www.festo.com/catalogue/...
Subject to change – 2013/01
Solenoid valves MEBH, ISO 5599-1
Technical data – 5/3-way valves
-M-P-
Flow rate
1200 … 4600 l/min
Voltage
24 V DC
General technical data
ISO size
1
2
3
Valve function
Constructional design
Sealing principle
Actuation type
Type of reset
Type of pilot control
Pilot air supply
Direction of flow
Exhaust function
Manual override
Type of mounting
Mounting position
Nominal size
Standard nominal flow rate
5/3-way, double solenoid
Piston spool
Soft
Electrical
Mechanical spring
Piloted
Internal
Non-reversible
With flow control
Via accessory, detenting
Via through-holes
Any
8
1200
11
2300
14.5
4100
4600
4000
71
G½
1120
Closed
Exhausted
Pressurised
Grid dimension
Pneumatic connection on sub-base
Product weight
Noise level
[mm]
[l/min]
[l/min]
[l/min]
[mm]
[g]
[dB (A)]
43
G¼
630
85
56
Gy
800
[bar]
[bar]
[bar]
[°C]
[°C]
Compressed air in accordance with ISO 8573-1:2010 [7:4:4]
Compressed air in accordance with ISO 8573-1:2010 [7:4:4]
Operation with lubricated medium possible (in which case lubricated operation will
always be required)
3 … 10
–0.9 … +16
3 … 10
–5 … +50
–5 … +50
Operating and environmental conditions
Operating medium
Pilot medium
Note on operating/pilot medium
Operating pressure
Internal pilot air supply
External pilot air supply
Pilot pressure
Ambient temperature
Temperature of medium
*
Valve response times [ms]
ISO size
1
On
Off
2
On
Off
3
On
Off
68
30
106
38
130
With EB solenoid coil
19
2013/01 – Subject to change
Internet: www.festo.com/catalogue/...
49
Solenoid valves MEBH, ISO 5599-1
Technical data – 5/3-way valves
Electrical data
EB solenoid coil
Electrical connection
Operating voltage
Coil characteristics
Protection class to EN 60 529
D.C. voltage
D.C. voltage
[V DC]
[W]
Central plug, round design, M12x1
24
2.5
IP65
Materials
Sectional view
1
1
–
50
Housing
Seals
Die-cast aluminium, polyacetate
Nitrile rubber
Internet: www.festo.com/catalogue/...
Subject to change – 2013/01
Solenoid valves MEBH, ISO 5599-1
Technical data – 5/3-way valves
Download CAD data www.festo.com
Dimensions
1 Attachment of plug socket
adjustable by 3x 30°
2 Manual override
3 Captive mounting screws
5 LED display
6 Angled socket
SEA-M12-4WD-PG7
101
ISO size
B1
B2
B3
B4
D1
H1
H2
H3
H4
H5
L1
L2
L3
L4
L5
L6
1
2
3
42
54
65
28
38
48
6
9
12
17.5
17.5
17.5
M5
M6
M8
110
120
130
80.3
90.1
97.8
38
48
55
9
9.5
12
74.7
84.2
93.1
134
151.8
171.9
108.4
158
184
54.2
79
92
36
48
64
18
24
32
67
75.9
86
M12 central plug – Terminal allocation
Duo connection
2
1
3
4
2013/01 – Subject to change
1
2
3
4
Unused
Signal (+) Solenoid 12
com (–)
Signal (+) Solenoid 14
Internet: www.festo.com/catalogue/...
51
Solenoid valves MEBH, ISO 5599-1
Technical data – 5/3-way valves
Ordering data
Circuit symbol
52
Description
Voltage
ISO size
Part No.
Type
With EB solenoid coil,
with central plug,
normally closed,
internal pilot air supply
24 V DC
1
2
3
184498
184505
184512
MEBH-5/3G-D-1-ZSR-C
MEBH-5/3G-D-2-ZSR-C
MEBH-5/3G-D-3-ZSR-C
With EB solenoid coil,
with central plug,
normally exhausted,
internal pilot air supply
24 V DC
1
2
3
184497
184504
184511
MEBH-5/3E-D-1-ZSR-C
MEBH-5/3E-D-2-ZSR-C
MEBH-5/3E-D-3-ZSR-C
With EB solenoid coil,
with central plug,
normally pressurised,
internal pilot air supply
24 V DC
1
2
3
184499
184506
184513
MEBH-5/3B-D-1-ZSR-C
MEBH-5/3B-D-2-ZSR-C
MEBH-5/3B-D-3-ZSR-C
Internet: www.festo.com/catalogue/...
Subject to change – 2013/01
Solenoid valves MDH-M12, ISO 5599-1
Technical data – 5/2-way valves
-M-P-
Flow rate
1,200 … 4,500 l/min
Voltage
24 V DC
General technical data
ISO size
1
Valve function
Design
Sealing principle
Actuation type
Type of reset
Type of actuation
Pilot air supply
Direction of flow
Exhaust function
Manual override
Type of mounting
Mounting position
Nominal size
Standard nominal flow rate
Grid dimension
Pneumatic connection on sub-base
Product weight
5/2-way, monostable
Piston slide
Soft
Electrical
Mechanical or pneumatic spring
Piloted
Internal or external
Reversible for external pilot air supply
Restrictablel
Via tool accessory, detenting
Via through-holes
Any
8
11
1,200
2,300
43
56
G¼
Gy
420
810
[mm]
[l/min]
[mm]
[g]
Operating and environmental conditions
Type of reset
pneumatic spring
Operating medium
Note on operating/pilot medium
Operating pressure
Pilot pressure
Ambient temperature
Temperature of medium
internal pilot air supply
external pilot air supply
2
[bar]
[bar]
[bar]
[°C]
[°C]
3
14.5
4,500
71
G½
1,000
mechanical spring
Compressed air in accordance with ISO 8573-1:2010 [7:4:4]
Operation with lubricated medium possible (in which case lubricated operation will
always be required)
2 … 10
3 … 10
–0.9 … +16
2 … 10
3 … 10
–10 … +50
–10 … +50
*
Valve response times
ISO size
Type of reset
D solenoid coil with M12x1 plug
On
Off
2013/01 – Subject to change
[ms]
[ms]
1
pneumatic
mechanical
2
pneumatic
mechanical
3
pneumatic
mechanical
25
36
20
42
45
60
25
60
55
60
30
70
Internet: www.festo.com/catalogue/...
53
Solenoid valves MDH-M12, ISO 5599-1
Technical data – 5/2-way valves
Electrical data
D solenoid coil with round plug M12x1
Electrical connection
Type
Coil characteristics
D.C. voltage
Power
Duty cycle
Protection class to EN 60 529
[V DC]
[Watt]
%
M12X1
21.6…26.4
2.7
100
IP65
Materials
Sectional view
1
1
–
54
Body
Seals
Die-cast aluminium, polyacetate
Nitrile rubber
Internet: www.festo.com/catalogue/...
Subject to change – 2013/01
Solenoid valves MDH-M12, ISO 5599-1
Technical data – 5/2-way valves
Download CAD data www.festo.com
Dimensions
1 Solenoid coil can be repositioned by 90° regardless of
manual override
2 Manual override facility
3 Captive mounting screws
4 Slot for inscription label
5 LED display
6 Plug socket M12x1
Coil 2-pin to VDMA
Coil 4-pin to Desina
Type
B1
B2
B3
B4
D1
H1
H2
H3
H4
H5
L1
L2
L3
L4
L5
ISO size 1
MDH-5/2-…
MDH-5/2-…-FR
42
28
6
30
M5
87.2
77.3
38
9
46.5
121.8
132.2
87.6
98
43.8
36
18
ISO size 2
MDH-5/2-…
MDH-5/2-…-FR
54
38
9
30
M6
97.2
87.2
48
9.5
56.5
144.6
161.9
123.4
140.6
61.7
48
24
ISO size 3
MDH-5/2-…
MDH-5/2-…-FR
65
48
12
30
M8
104.2
94.2
55
12
62.7
165.9
185.2
145.4
164.7
72.7
64
32
M12 plug – Pin allocation 2-pin to VDMA
2
1
3
4
2013/01 – Subject to change
M12 plug – Pin allocation 4-pin to Desina
1
2
3
4
Unused
Unused
com (–)
Signal (+)
1
2
3
4
Internet: www.festo.com/catalogue/...
connected with 2
connected with 1
com (–)
Signal (+)
55
Solenoid valves MDH-M12, ISO 5599-1
Technical data – 5/2-way valves
Ordering data
Circuit symbol
56
Description
ISO
size
Part No.
Type
197125
533008
533009
540803
540812
540819
533332
MDH-5/2-D-1-M12-C
MDH-5/2-D-2-M12-C
MDH-5/2-D-3-M12-C
MDH-5/2-D-1-M12D-C
MDH-5/2-D-2-M12D-C
MDH-5/2-D-3-M12D-C
MDH-5/2-D-1-S-M12-C
Type of reset:
– pneumatic
Pilot air supply:
– internal
Coil 2-pin to VDMA
Type of reset:
– pneumatic
Pilot air supply:
– external
Coil 2-pin to VDMA
1
2
3
1
2
3
1
Coil 4-pin to Desina
1
540810
MDH-5/2-D-1-S-M12D-C
Type of reset:
– mechanical
Pilot air supply:
– internal
Coil 2-pin to VDMA
Type of reset:
– mechanical
Pilot air supply:
– external
Coil 2-pin to VDMA
1
2
3
1
2
3
1
533010
533011
533012
540804
540813
540820
533761
MDH-5/2-D-1-FR-M12-C
MDH-5/2-D-2-FR-M12-C
MDH-5/2-D-3-FR-M12-C
MDH-5/2-D-1-FR-M12D-C
MDH-5/2-D-2-FR-M12D-C
MDH-5/2-D-3-FR-M12D-C
MDH-5/2-D-1S-FR-M12-C
Coil 4-pin to Desina
1
540811
MDH-5/2-D-1S-FR-M12D-C
Coil 4-pin to Desina
Coil 4-pin to Desina
Internet: www.festo.com/catalogue/...
Subject to change – 2013/01
Solenoid valves JMDH-M12, ISO 5599-1
Technical data – 5/2-way valves, double solenoid
-M-P-
Flow rate
1,200 … 4,500 l/min
Voltage
24 V DC
General technical data
ISO size
1
2
3
Valve function
Design
Sealing principle
Actuation type
Type of actuation
Pilot air supply
Direction of flow
Exhaust function
Manual override
Type of mounting
Mounting position
Nominal size
Standard nominal flow rate
Grid dimension
Pneumatic connection on sub-base
Product weight
[g]
5/2-way, bistable
Piston spool
Soft
Electrical
Piloted
Internal
Non-reversible
Restrictable
Via tool accessory, detenting
Via through-holes
Any
8
1,200
43
G¼
550
11
2,300
56
Gy
810
14.5
4,000
71
G½
1,100
[bar]
[°C]
[°C]
Compressed air in accordance with ISO 8573-1:2010 [7:4:4]
Operation with lubricated medium possible (in which case lubricated operation will
always be required)
2 … 10
–10… +50
–10 … +50
[mm]
[l/min]
[mm]
Operating and environmental conditions
Operating medium
Note on operating/pilot medium
Operating pressure
Ambient temperature
Temperature of medium
internal pilot air supply
*
Valve response times
ISO size
1
2
3
18
22
25
D solenoid coil with round plug M12x1
[ms]
2013/01 – Subject to change
Internet: www.festo.com/catalogue/...
57
Solenoid valves JMDH-M12, ISO 5599-1
Technical data – 5/2-way valves, double solenoid
Electrical data
D solenoid coil with round plug
Electrical connection
Coil characteristics
Duty cycle
Protection class to EN 60 529
Type
D.C. voltage
Power
[V DC]
[Watt]
%
M12X1
21.6…26.4
2.7
100
IP65
Materials
Sectional view
1
1
–
58
Body
Seals
Die-cast aluminium, polyacetate
Nitrile rubber
Internet: www.festo.com/catalogue/...
Subject to change – 2013/01
Solenoid valves JMDH-M12, ISO 5599-1
Technical data – 5/2-way valves, double solenoid
Download CAD data www.festo.com
Dimensions
1 Solenoid coil can be repositioned by 90° regardless of
manual override
2 Manual override facility
3 Captive mounting screws
5 LED display
6 Plug socket M12x1
Coil 2-pin to VDMA
Coil 4-pin to Desina
ISO size
B1
B2
B3
B4
D1
H1
H2
H3
H4
L1
L2
L3
L4
L5
L6
1
2
3
42
54
65
28
38
48
6
9
12
30
30
30
M5
M6
M8
87.2
97.2
104.2
77.2
87.2
94.2
38
48
55
9
9.5
12
148
165.8
186.4
87.6
123.4
145.4
43.8
61.7
72.7
36
48
64
18
24
32
108.5
126.3
146.9
M12 plug – Pin allocation 2-pin to VDMA
2
1
3
4
2013/01 – Subject to change
M12 plug – Pin allocation 4-pin to Desina
1
2
3
4
Unused
Unused
com (–)
Signal (+)
1
2
3
4
Internet: www.festo.com/catalogue/...
connected with 2
connected with 1
com (–)
Signal (+)
59
Solenoid valves JMDH-M12, ISO 5599-1
Technical data – 5/2-way valves, double solenoid
Ordering data
Circuit symbol
Description
Pilot air supply:
– internal
Coil 2-pin to VDMA
Coil 4-pin to Desina
Pilot air supply:
– internal
Dominant:
– signal at 14
60
Coil 2-pin to VDMA
Coil 4-pin to Desina
Internet: www.festo.com/catalogue/...
ISO
size
Part No.
Type
1
2
3
1
2
3
1
2
3
1
2
3
532687
533013
533015
540809
540818
540825
539079
539077
539081
540808
540817
540824
JMDH-5/2-D-1-M12-C
JMDH-5/2-D-2-M12-C
JMDH-5/2-D-3-M12-C
JMDH-5/2-D-1-M12D-C
JMDH-5/2-D-2-M12D-C
JMDH-5/2-D-3-M12D-C
JMDDH-5/2-D-1-M12-C
JMDDH-5/2-D-2-M12-C
JMDDH-5/2-D-3-M12-C
JMDDH-5/2-D-1-M12D-C
JMDDH-5/2-D-2-M12D-C
JMDDH-5/2-D-3-M12D-C
Subject to change – 2013/01
Solenoid valves MDH-M12, ISO 5599-1
Technical data – 5/3-way valves
-M-P-
Flow rate
1,200 … 4,600 l/min
Voltage
24 V DC
General technical data
ISO size
1
Valve function
Design
Sealing principle
Actuation type
Type of reset
Type of actuation
Pilot air supply
Direction of flow
Exhaust function
Manual override
Type of mounting
Mounting position
Nominal size
Standard nominal flow rate
5/3-way, monostable
Piston spool
Soft
Electrical
Mechanical spring
Piloted
Internal
Non-reversible
Restrictable
Via tool accessory, detenting
Via through-holes
Any
8
11
1,200
2,300
[mm]
[l/min]
Grid dimension
Pneumatic connection on sub-base
Product weight
[mm]
2
3
14.5
4,000 (B),
4,100 (G),
4,600 (E)
71
G½
1,120
[g]
43
G¼
580
56
Gy
880
[bar]
[°C]
[°C]
Compressed air in accordance with ISO 8573-1:2010 [7:4:4]
Operation with lubricated medium possible (in which case lubricated operation will
always be required)
3 … 10
–10 … +50
–10 … +50
Operating and environmental conditions
Operating medium
Note on operating/pilot medium
Operating pressure
Ambient temperature
Temperature of medium
internal pilot air supply
*
Valve response times
ISO size
1
On
Off
2
On
Off
3
On
Off
25
55
35
70
36
90
with D solenoid coil with round plug M12x1
[ms]
2013/01 – Subject to change
Internet: www.festo.com/catalogue/...
61
Solenoid valves MDH-M12, ISO 5599-1
Technical data – 5/3-way valves
Electrical data
D solenoid coil with round plug
Electrical connection
Coil characteristics
Duty cycle
Protection class to EN 60 529
Type
D.C. voltage
Power
[V DC]
[Watt]
%
M12X1
21.6…26.4
2.7
100
IP65
Materials
Sectional view
1
1
–
62
Body
Seals
Die-cast aluminium, polyacetate
Nitrile rubber
Internet: www.festo.com/catalogue/...
Subject to change – 2013/01
Solenoid valves MDH-M12, ISO 5599-1
Technical data – 5/3-way valves
Download CAD data www.festo.com
Dimensions
1 Solenoid coil can be repositioned by 90° regardless of
manual override
2 Manual override facility
3 Captive mounting screws
5 LED display
6 Plug socket M12x1
Coil 2-pin to VDMA
Coil 4-pin to Desina
ISO size
B1
B2
B3
B4
D1
H1
H2
H3
H4
L1
L2
L3
L4
L5
L6
1
2
3
42
54
65
28
38
48
6
9
12
30
30
30
M5
M6
M8
87.2
97.2
104.2
77.2
87.2
94.2
38
48
55
9
9.5
12
148
165.8
186.4
108.4
158
184
54.3
79
92
36
48
64
18
24
32
108.5
126.3
146.9
M12 plug – Pin allocation 2-pin to VDMA
2
1
3
4
2013/01 – Subject to change
M12 plug – Pin allocation 4-pin to Desina
1
2
3
4
Unused
Unused
com (–)
Signal (+)
1
2
3
4
Internet: www.festo.com/catalogue/...
connected with 2
connected with 1
com (–)
Signal (+)
63
Solenoid valves MDH-M12, ISO 5599-1
Technical data – 5/3-way valves
Ordering data
Circuit symbol
64
Description
Normal position:
– closed
Pilot air supply:
– internal
Coil 2-pin to VDMA
Normal position:
– exhausted
Pilot air supply:
– internal
Coil 2-pin to VDMA
Normal position:
– pressurised
Pilot air supply:
– internal
Coil 2-pin to VDMA
Coil 4-pin to Desina
Coil 4-pin to Desina
Coil 4-pin to Desina
Internet: www.festo.com/catalogue/...
ISO
size
Part No.
Type
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
525307
539078
539080
540806
540815
540822
197126
533016
533017
540805
540814
540821
533005
533006
533007
540807
540816
540823
MDH-5/3G-D-1-M12-C
MDH-5/3G-D-2-M12-C
MDH-5/3G-D-3-M12-C
MDH-5/3G-D-1-M12D-C
MDH-5/3G-D-2-M12D-C
MDH-5/3G-D-3-M12D-C
MDH-5/3E-D-1-M12-C
MDH-5/3E-D-2-M12-C
MDH-5/3E-D-3-M12-C
MDH-5/3E-D-1-M12D-C
MDH-5/3E-D-2-M12D-C
MDH-5/3E-D-3-M12D-C
MDH-5/3B-D-1-M12-C
MDH-5/3B-D-2-M12-C
MDH-5/3B-D-3-M12-C
MDH-5/3B-D-1-M12D-C
MDH-5/3B-D-2-M12D-C
MDH-5/3B-D-3-M12D-C
Subject to change – 2013/01
Solenoid valves MDH, ISO 5599-1
Technical data – 5/2-way valves
-M-P-
Flow rate
Voltage
24 V DC
42, 110, 230 V AC
General technical data
ISO size
4
Valve function
Constructional design
Sealing principle
Actuation type
Type of reset
Type of pilot control
Pilot air supply
Direction of flow
Exhaust function
Manual override
Type of mounting
Mounting position
Nominal size
Standard nominal flow rate
Grid dimension
Pneumatic connection on sub-base
Product weight
[g]
5/2-way, single solenoid
Piston spool
Soft
Electrical
Pneumatic spring
Piloted
Internal
Non-reversible
With flow control
Via accessory, detenting
Via through-holes
Any
18
6000
82
G¾
2600
[bar]
[bar]
[bar]
[°C]
[°C]
Compressed air in accordance with ISO 8573-1:2010 [7:4:4]
Operation with lubricated medium possible (in which case lubricated operation will
always be required)
3 … 16
–
–
–5 … +40
–10 … +60
[mm]
[l/min]
[mm]
Operating and environmental conditions
Operating medium
Note on operating/pilot medium
Operating pressure
Pilot pressure
Ambient temperature
Temperature of medium
Internal pilot air supply
External pilot air supply
*
Valve response times [ms]
D solenoid coil
On
120
Off
160
2013/01 – Subject to change
Internet: www.festo.com/catalogue/...
65
Solenoid valves MDH, ISO 5599-1
Technical data – 5/2-way valves
Electrical data
D solenoid coil
Electrical connection
Operating voltage
Coil characteristics
Design
D.C. voltage
A.C. voltage
D.C. voltage
A.C. voltage
42 V
A.C. voltage 110 V, 230 V
Protection class to EN 60 529
[V DC]
[V AC]
[W]
[VA]
[VA]
Plug, square design to EN 175301-803, type A
24
42, 110, 230 (50 … 60 Hz)
6.8
Pull: 16.5
Hold: 12.2
Pull: 14.4
Hold: 10.5
IP65
Materials
Sectional view
1
1
–
66
Housing
Seals
Anodised aluminium, polyacetate, brass
Nitrile rubber, polyurethane, polytetrafluoroethylene carbon
Internet: www.festo.com/catalogue/...
Subject to change – 2013/01
Solenoid valves MDH, ISO 5599-1
Technical data – 5/2-way valves
Download CAD data www.festo.com
Dimensions
1 Wiring at plug socket to
EN 175301-803, type A
100
2 Manual override
3 Captive mounting screws
4 Solenoid coil can be
repositioned by 90° regardless
of manual override
Ordering data
Description
Voltage
ISO size
Part No.
Type
With D solenoid coil,
pneumatic reset,
internal pilot air supply
24 V DC
4
12457
MDH-5/2-¾-D-4-24DC
14544
MDH-5/2-¾-D-41)
Electrical connection to
EN 175301-803 type A
24 V DC
110 V AC
230 V AC
24 V DC/
42 V AC
119600
119601
119602
119603
MDH-3/2-24DC
MDH-3/2-110AC
MDH-3/2-230AC
MDH-3/2-24DC/42AC
–
Usable pilot valves
1)
–
–
–
–
Without pilot valve. The part number for the pilot valve must be quoted when ordering.
Order example: 14544 MDH-5/2-¾-D-4-119602
2013/01 – Subject to change
Internet: www.festo.com/catalogue/...
67
Solenoid valves JMDH, ISO 5599-1
Technical data – 5/2-way valves, double solenoid
-M-P-
Flow rate
6000 l/min
Voltage
24 V DC
42, 110, 230 V AC
General technical data
ISO size
4
Valve function
Constructional design
Sealing principle
Actuation type
Type of pilot control
Pilot air supply
Direction of flow
Exhaust function
Manual override
Type of mounting
Mounting position
Nominal size
Standard nominal flow rate
Grid dimension
Pneumatic connection on sub-base
Product weight
[g]
5/2-way, double solenoid
Piston spool
Soft
Electrical
Piloted
Internal
Non-reversible
With flow control
Via accessory, detenting
Via through-holes
Any
18
6000
82
G¾
2600
[bar]
[bar]
[bar]
[°C]
[°C]
Compressed air in accordance with ISO 8573-1:2010 [7:4:4]
Operation with lubricated medium possible (in which case lubricated operation will
always be required)
2 … 16
–
–
–5 … +40
–10 … +60
[mm]
[l/min]
[mm]
Operating and environmental conditions
Operating medium
Note on operating/pilot medium
Operating pressure
Pilot pressure
Ambient temperature
Temperature of medium
Internal pilot air supply
External pilot air supply
*
Valve response times [ms]
With D solenoid coil
40
68
Internet: www.festo.com/catalogue/...
Subject to change – 2013/01
Solenoid valves JMDH, ISO 5599-1
Technical data – 5/2-way valves, double solenoid
Electrical data
D solenoid coil
Electrical connection
Operating voltage
Coil characteristics
D.C. voltage
A.C. voltage
D.C. voltage
A.C. voltage
42 V
A.C. voltage 110 V, 230 V
[V DC]
[V AC]
[W]
[VA]
[VA]
Protection class to EN 60 529
Plug, square design to EN 175301-803, type A
24
42, 110, 230 (50 … 60 Hz)
6.8
Pull: 16.5
Hold: 12.2
Pull: 14.5
Hold: 10.5
IP65
Materials
Sectional view
1
1
–
Housing
Seals
2013/01 – Subject to change
Anodised aluminium, polyacetate, brass
Nitrile rubber, polyurethane, polytetrafluoroethylene carbon
Internet: www.festo.com/catalogue/...
69
Solenoid valves JMDH, ISO 5599-1
Technical data – 5/2-way valves, double solenoid
Download CAD data www.festo.com
Dimensions
1 Wiring at plug socket to
EN 175301-803, type A
100
2 Manual override
3 Captive mounting screws
4 Solenoid coil can be
repositioned by 90° regardless
of manual override
Ordering data – Double solenoid valve
Description
Voltage
ISO size
Part No.
Type
With D solenoid coil,
internal pilot air supply
24 V DC
4
12458
JMDH-5/2-¾-D-4-24DC
14545
JMDH-5/2-¾-D-41)
119600
119601
119602
119603
MDH-3/2-24DC
MDH-3/2-110AC
MDH-3/2-230AC
MDH-3/2-24DC/42AC
–
Usable pilot valves
Electrical connection to
EN 175301-803 type A
1)
70
24 V DC
110 V AC
230 V AC
24 V DC/
42 V AC
–
–
–
–
Without pilot valve. The part number for the pilot valve must be quoted when ordering.
Order example: 14545 MDH-5/2-¾-D-4-119602
Internet: www.festo.com/catalogue/...
Subject to change – 2013/01
Solenoid valves MDH, ISO 5599-1
Technical data – 5/3-way valves
-M-P-
Flow rate
4800 l/min
Voltage
24 V DC
42, 110, 230 V AC
General technical data
ISO size
4
Valve function
Constructional design
Sealing principle
Actuation type
Type of reset
Type of pilot control
Pilot air supply
Direction of flow
Exhaust function
Manual override
Type of mounting
Mounting position
Nominal size
Standard nominal flow rate
Closed
Exhausted
Grid dimension
Pneumatic connection on sub-base
Product weight
[g]
5/3-way, double solenoid
Piston spool
Soft
Electrical
Pneumatic spring
Piloted
Internal
Non-reversible
With flow control
Via accessory, detenting
Via through-holes
Any
18
4800
4800
82
G¾
2600
[bar]
[bar]
[bar]
[°C]
[°C]
Compressed air in accordance with ISO 8573-1:2010 [7:4:4]
Operation with lubricated medium possible (in which case lubricated operation will
always be required)
3 … 16
–
–
– 5 … +40
–10 … +60
[mm]
[l/min]
[l/min]
[mm]
Operating and environmental conditions
Operating medium
Note on operating/pilot medium
Operating pressure
Internal pilot air supply
External pilot air supply
Pilot pressure
Ambient temperature
Temperature of medium
*
Valve response times [ms]
With D solenoid coil
On
Off
85
290
2013/01 – Subject to change
Internet: www.festo.com/catalogue/...
71
Solenoid valves MDH, ISO 5599-1
Technical data – 5/3-way valves
Electrical data
D solenoid coil
Electrical connection
Operating voltage
Coil characteristics
D.C. voltage
A.C. voltage
D.C. voltage
A.C. voltage
42 V
A.C. voltage 110 V, 230 V
[V DC]
[V AC]
[W]
[VA]
[VA]
Plug, square design to EN 175301-803, type A
24
42, 110, 230 (50 … 60 Hz)
6.8
Pull: 16.5
Hold: 12.2
Pull: 14.5
Hold: 10.5
Materials
Sectional view
1
1
–
72
Housing
Seals
Anodised aluminium, polyacetate, brass
Nitrile rubber, polyurethane, polytetrafluoroethylene carbon
Internet: www.festo.com/catalogue/...
Subject to change – 2013/01
Solenoid valves MDH, ISO 5599-1
Technical data – 5/3-way valves
Download CAD data www.festo.com
Dimensions
1 Wiring at plug socket to
EN 175301-803, type A
100
2 Manual override
3 Captive mounting screws
4 Solenoid coil can be
repositioned by 90° regardless
of manual override
Ordering data
Description
Voltage
ISO size
Part No.
Type
With D solenoid coil,
normally closed,
internal pilot air supply
24 V DC
4
12459
MDH-5/3G-¾-D-4-24DC
14546
MDH-5/3G-¾-D-41)
With D solenoid coil,
normally exhausted,
internal pilot air supply
24 V DC
12460
MDH-5/3E-¾-D-4-24DC
14547
MDH-5/3E-¾-D-41)
Electrical connection to
EN 175301-803 type A
24 V DC
110 V AC
230 V AC
24 V DC/
42 V AC
119600
119601
119602
119603
MDH-3/2-24DC
MDH-3/2-110AC
MDH-3/2-230AC
MDH-3/2-24DC/42AC
–
4
–
Usable pilot valves
1)
–
–
–
–
Without pilot valve. The part number for the pilot valve must be quoted when ordering.
Order example: 14546 MDH-5/3G-¾-D-4-119602
2013/01 – Subject to change
Internet: www.festo.com/catalogue/...
73
Pneumatic valves, ISO 5599-1
Type code
VL
—
5/3
G
—
D-1
—
—
C
Type
VL
J
JD
Single pilot
Double pilot
Double pilot, with dominant signal
Valve function
5/2
5/3
5/2-way valve
5/3-way valve
Normal position
G
E
B
Closed
Exhausted
Pressurised
Size
D-1
D-2
D-3
¾-D-4
ISO size 1
ISO size 2
ISO size 3
ISO size 4
Type of reset
FR
Mechanical spring
Pneumatic spring
Generation
C
74
Series C
Internet: www.festo.com/catalogue/...
Subject to change – 2013/01
Pneumatic valves, ISO 5599-1
Peripherals overview
Individual mounting
4
1
3
2
1
3
Variants
J-5/…-¾-D-4,
VL-5/…-¾-D-4
Accessories
Brief description
Page/Internet
For connecting compressed air tubing with standard O.D.
quick star
NAS – With lateral ports
NAU – With ports underneath
For fitting in exhaust ports
88
3
Push-in fitting
QS
Individual sub-base
NAS/NAU
Silencer
4
Pneumatic valve
Port pattern to ISO 5599-1
6
1
2
u
Port pattern on sub-base to ISO 5599-1
Defined interfaces between valve and sub-base
ISO 1
ISO 2
ISO 3
ISO 4
aD
5
4
1
2
3
aB
2013/01 – Subject to change
Internet: www.festo.com/catalogue/...
75
Pneumatic valves, ISO 5599-1
Peripherals overview
Manifold mounting
9
aB
8
aA
2
9
8
aJ
1
7
9
2
3
4
2
5
8
6
4
1
2
8
76
Internet: www.festo.com/catalogue/...
Subject to change – 2013/01
Pneumatic valves, ISO 5599-1
Peripherals overview
Accessories
Brief description
Page/Internet
For sealing the manifold sub-bases
91
For connecting compressed air tubing with standard O.D.
quick star
For routing ports 2 and 4 to the front
90
With ports 2 and 4 on the bottom
90
For sealing the common lines 1, 3, 5 between end plates and manifold sub-bases or between
2 manifold sub-bases, e.g. for different working pressures
For connecting manifold sub-bases of different sizes
92
With ports 2 and 4 either on the bottom or the front
91
8
End plate kit
NEV
Push-in fitting
QS
Angle connection block
NAW
Manifold sub-base
NAV
Isolating disc
NSC
Intermediate plate
NZV
Manifold sub-base for angle connection
NAVW
Silencer
For fitting in exhaust ports
u
9
Pneumatic valve
Port pattern to ISO 5599-1
6
aJ
Blanking plate
NDV
Throttle plate for ISO size 1, 2 and 3
GRO
Intermediate pressure regulator plate
for ISO size 1, 2 and 3
LR-ZP
For sealing unused manifold sub-bases
92
With integrated exhaust air restrictors at port 3 and 5. The throttle plate is mounted between
the valve and the individual sub-base/manifold sub-base
For regulating the pressure from 0 to 12 bar according to the supply pressure.
The intermediate pressure regulator plate is mounted between the valve and the individual
sub-base/manifold sub-base
95
1
2
3
4
5
6
7
aA
aB
94
96
Port pattern on sub-base to ISO 5599-1
Defined interfaces between valve and sub-base
ISO 1
ISO 2
ISO 3
ISO 4
aD
5
4
1
2
3
aB
2013/01 – Subject to change
Internet: www.festo.com/catalogue/...
77
Pneumatic valves VL, ISO 5599-1
Technical data – 5/2-way valves
-M-
Flow rate
1200 … 6000 l/min
General technical data
ISO size
Valve function
Constructional design
Sealing principle
Actuation type
Type of reset
Type of pilot control
Direction of flow
1
Type of reset mechanical spring
Type of reset pneumatic spring
Exhaust function
Manual override
Type of mounting
Mounting position
Nominal size
Standard nominal flow rate
Grid dimension
Pneumatic connection on sub-base
[mm]
[l/min]
[mm]
1, 2, 3, 4, 5
12, 14
[g]
[dB (A)]
Product weight
Noise level
Certification
Operating and environmental conditions
ISO size
Type of reset
1, 2, 3
Pneumatic
Operating medium
Note on operating/pilot medium
Operating pressure
Pilot pressure
Ambient temperature
Temperature of medium
[bar]
[bar]
[°C]
[°C]
2
3
5/2-way, single pilot
Piston spool
Soft
Pneumatic
Mechanical or pneumatic spring
Direct
Reversible
Non-reversible
With flow control
None
Via through-holes
Any
8
11
1200
2300
43
56
G¼
Gy
Gx
Gx
290
550
85
Germanischer Lloyd
UL - recognized (OL)
Mechanical
4
Mechanical spring
14.5
4500
71
G½
Gx
810
18
6000
82
G¾
Gx
1800
4
Mechanical
Compressed air in accordance with ISO 8573-1:2010 [7:4:4]
Operation with lubricated medium possible (in which case lubricated operation will
always be required)
2 … 16
–0.9 … 16
–0.9 … +16
2 … 16
3 … 16
3 … 16
–10 … +60
–10 … +60
*
78
Internet: www.festo.com/catalogue/...
Subject to change – 2013/01
Pneumatic valves VL, ISO 5599-1
Technical data – 5/2-way valves
Valve response times
ISO size
1
Type of reset
Pneumatic
Mechanical
2
Pneumatic
Mechanical
3
Pneumatic
Mechanical
4
Pneumatic
Mechanical
On
Off
6
23
23
39
11
39
29
36
13
43
–
–
25
90
9
18
Materials
Sectional view (ISO size 1, 2, 3)
1
ISO size
1 Housing
–
Seals
2013/01 – Subject to change
1, 2, 3
Die-cast aluminium, polyacetate
Nitrile rubber
4
Anodised aluminium, brass, polyurethane
Nitrile rubber, polytetrafluoroethylene carbon
Internet: www.festo.com/catalogue/...
79
Pneumatic valves VL, ISO 5599-1
Technical data – 5/2-way valves
Download CAD data www.festo.com
Dimensions
ISO size 1, 2, 3
3 Captive mounting screws
Type
B1
B2
B3
D1
H3
H4
H5
L2
L3
L4
L5
ISO size 1
VL-5/2-…
VL-5/2-…-FR
42
28
6
M5
38
9
46.5
87.6
98
43.8
36
18
ISO size 2
VL-5/2-…
VL-5/2-…-FR
54
38
9
M6
48
9.5
56.5
123.4
140.7
61.7
48
24
ISO size 3
VL-5/2-…
VL-5/2-…-FR
65
48
12
M8
55
12
63.5
145.4
164.7
72.7
64
32
80
Internet: www.festo.com/catalogue/...
Subject to change – 2013/01
Pneumatic valves VL, ISO 5599-1
Technical data – 5/2-way valves
Download CAD data www.festo.com
Dimensions
ISO size 4
3 Captive mounting screws
Ordering data
Circuit symbol
2013/01 – Subject to change
Description
ISO size
Part No.
Type
Pneumatic reset
1
2
3
151009
151845
151864
VL-5/2-D-1-C
VL-5/2-D-2-C
VL-5/2-D-3-C
Mechanical reset
1
2
3
4
151014
151844
151863
12461
VL-5/2-D-1-FR-C
VL-5/2-D-2-FR-C
VL-5/2-D-3-FR-C
VL-5/2-¾-D-4
Internet: www.festo.com/catalogue/...
81
Pneumatic valves J, ISO 5599-1
Technical data – 5/2-way valves, double pilot
-M-
Flow rate
1200 … 6000 l/min
General technical data
ISO size
1
Valve function
Constructional design
Sealing principle
Actuation type
Type of pilot control
Direction of flow
Exhaust function
Manual override
Type of mounting
Mounting position
Nominal size
Standard nominal flow rate
Grid dimension
Pneumatic connection on sub-base
[mm]
[l/min]
[mm]
1, 2, 3, 4, 5
12, 14
[g]
[dB (A)]
Product weight
Noise level
Certification
2
5/2-way, double pilot
Piston spool
Soft
Pneumatic
Direct
Reversible
With flow control
None
Via through-holes
Any
8
11
1200
2300
43
56
G¼
Gy
Gx
Gx
290
550
85
Germanischer Lloyd
UL - recognized (OL)
3
4
14.5
4500
71
G½
Gx
810
18
6000
82
G¾
Gx
1800
Operating and environmental conditions
Operating medium
Note on operating/pilot medium
Operating pressure
Pilot pressure
Ambient temperature
Temperature of medium
[bar]
[bar]
[°C]
[°C]
Compressed air in accordance with ISO 8573-1:2010 [7:4:4]
Operation with lubricated medium possible (in which case lubricated operation will
always be required)
–0.9 … 16
2 … 16
–10 … +60
–10 … +60
*
Valve response times [ms]
ISO size
1
2, 3
Dominant signal at 14
6
82
6/4
Internet: www.festo.com/catalogue/...
4
Dominant signal at 14
8
8
20
Subject to change – 2013/01
Pneumatic valves J, ISO 5599-1
Technical data – 5/2-way valves, double pilot
Materials
Sectional view (ISO size 4)
1
ISO size
1 Housing
–
Seals
1, 2, 3
Die-cast aluminium, polyacetate
Nitrile rubber
4
Anodised aluminium, brass, polyurethane
Nitrile rubber, polytetrafluoroethylene carbon
Download CAD data www.festo.com
Dimensions
ISO size 1, 2, 3
3 Captive mounting screws
ISO size
B1
B2
B3
D1
H3
H4
H5
L2
L3
L4
L5
1
2
3
42
54
65
28
38
48
6
9
12
M5
M6
M8
38
48
55
9
9.5
12
46.5
56.5
63.5
87.6
123.4
145.4
43.8
61.7
72.7
36
48
64
18
24
32
2013/01 – Subject to change
Internet: www.festo.com/catalogue/...
83
Pneumatic valves J, ISO 5599-1
Technical data – 5/2-way valves, double pilot
Download CAD data www.festo.com
Dimensions
ISO size 4
3 Captive mounting screws
Ordering data
Circuit symbol
Description
With dominant signal at 14
84
Internet: www.festo.com/catalogue/...
ISO size
Part No.
Type
1
2
3
4
151007
151846
151865
12462
J-5/2-D-1-C
J-5/2-D-2-C
J-5/2-D-3-C
J-5/2-¾-D-4
1
151008
JD-5/2-D-1-C
2
151847
JD-5/2-D-2-C
3
151866
JD-5/2-D-3-C
Subject to change – 2013/01
Pneumatic valves VL, ISO 5599-1
Technical data – 5/3-way valves
-M-
Flow rate
1200 … 6000 l/min
General technical data
ISO size
1
Valve function
Constructional design
Sealing principle
Actuation type
Type of reset
Type of pilot control
Pilot air supply
Direction of flow
Exhaust function
Manual override
Type of mounting
Mounting position
Nominal size
Standard nominal flow rate
5/3-way, double pilot
Piston spool
Soft
Pneumatic
Mechanical spring
Direct
Internal
Reversible
With flow control
None
Via through-holes
Any
8
11
1200
2300
Closed
Exhausted
Pressurised
Grid dimension
Pneumatic connection on sub-base
Product weight
Noise level
Certification
[mm]
[l/min]
[l/min]
[l/min]
[mm]
1, 2, 3, 4, 5
12, 14
[g]
[dB (A)]
2
43
G¼
Gx
320
85
Germanischer Lloyd
UL - recognized (OL)
56
Gy
Gx
825
3
4
14.5
4100
4600
4100
71
G½
Gx
910
18
6000
4800
–
82
G¾
Gx
2000
Operating and environmental conditions
Operating medium
Note on operating/pilot medium
Operating pressure
Pilot pressure
Ambient temperature
Temperature of medium
[bar]
[bar]
[°C]
[°C]
Compressed air in accordance with ISO 8573-1:2010 [7:4:4]
Operation with lubricated medium possible (in which case lubricated operation will
always be required)
–0.9 … +16
3 … 16
–10 … +60
–10 … +60
*
Valve response times
ISO size
Closed
Exhausted
Pressurised
2013/01 – Subject to change
1
On
Off
2
On
Off
3
On
Off
4
On
Off
7
7
7
45
45
45
15
16
15
56
59
57
17
18
16
61
63
60
40
40
–
130
130
–
Internet: www.festo.com/catalogue/...
85
Pneumatic valves VL, ISO 5599-1
Technical data – 5/3-way valves
Materials
Sectional view (ISO size 4)
1
ISO size
1 Housing
–
Seals
1, 2, 3
Die-cast aluminium, polyacetate
Nitrile rubber
4
Anodised aluminium, brass, polyurethane
Nitrile rubber, polytetrafluoroethylene carbon
Download CAD data www.festo.com
Dimensions
ISO size 1, 2 and 3
3 Captive mounting screws
4 Slot for inscription label
ISO size
B1
B2
B3
D1
H3
H4
H5
L2
L3
L4
L5
1
2
3
42
54
65
28
38
48
6
9
12
M5
M6
M8
38
48
55
9
9.5
12
46.5
56.5
63.5
108.4
158
184
54.2
79
92
36
48
64
18
24
32
86
Internet: www.festo.com/catalogue/...
Subject to change – 2013/01
Pneumatic valves VL, ISO 5599-1
Technical data – 5/3-way valves
Download CAD data www.festo.com
Dimensions
ISO size 4
3 Captive mounting screws
Ordering data
Circuit symbol
2013/01 – Subject to change
Description
ISO size
Part No.
Type
Normally closed,
mechanical reset
1
2
3
4
151010
151848
151867
12463
VL-5/3G-D-1-C
VL-5/3G-D-2-C
VL-5/3G-D-3-C
VL-5/3G-¾-D-4
Normally exhausted,
mechanical reset
1
2
3
4
151011
151849
151868
12464
VL-5/3E-D-1-C
VL-5/3E-D-2-C
VL-5/3E-D-3-C
VL-5/3E-¾-D-4
Normally pressurised,
mechanical reset
1
2
3
151012
151850
151869
VL-5/3B-D-1-C
VL-5/3B-D-2-C
VL-5/3B-D-3-C
Internet: www.festo.com/catalogue/...
87
Solenoid/pneumatic valves, to ISO 5599-1
Accessories
Ports at side
Individual sub-base NAS
Materials:
ISO size 1, 2, 3:
Die-cast aluminium
ISO size 4:
Anodised aluminium
General technical data
Conforms to standard
Type of mounting
ISO 5599-1
2 through-holes in housing
Operating and environmental conditions
ISO size
1
Note on materials
Certification
Free of copper and PTFE
UL recognized (OL)
2
3
4
–
–
Download CAD data www.festo.com
Dimensions
ISO size
B1
D1
D2
D3
H1
H2
H4
H5
H6
L1
L2
L3
L4
L5
1
2
3
4
48
57
71
85
G¼
Gy
G½
G¾
Gx
Gx
Gx
Gx
5.5
6.6
6.6
9
32
40
32
42
10
13
18
19
9
9
9
9
20.3
25
16
21
20.3
25
16
21
110
124
149
186
98
112
136
170
23
27
32
42
60
71
91
111
46
54
64
84
Ordering data
Designation to VDMA
ISO size
Pneumatic connection
1, 2, 3, 4, 5 12, 14
Weight
[g]
Part No.
Type
VDMA 24345-A-1
VDMA 24345-A-2
VDMA 24345-A-3
VDMA 24345-A-4
1
2
3
4
G¼
Gy
G½
G¾
190
300
360
1,260
9484
11310
10336
152813
NAS-¼-1A-ISO
NAS-y-2A-ISO
NAS½-3A-ISO
NAS-¾-4A-ISO
Gx
Gx
Gx
Gx
-H- Note: This product conforms to ISO 1179-1 and to ISO 228-1
88
Internet: www.festo.com/catalogue/...
Subject to change – 2013/01
Solenoid/pneumatic valves, to ISO 5599-1
Accessories
Ports underneath
Individual sub-base NAU
Materials:
ISO size 1, 2, 3:
Die-cast aluminium
ISO size 4:
Anodised aluminium
General technical data
Conforms to standard
Type of mounting
ISO 5599-1
2 through-holes in housing
Operating and environmental conditions
ISO size
1
Note on materials
Certification
Free of copper and PTFE
UL recognized (OL)
2
3
4
–
–
–
Download CAD data www.festo.com
Dimensions
ISO size
B1
D1
D2
D3
H1
H2
H3
H4
H5
L1
L2
L3
L4
L5
1
2
3
4
46
56
71
85
G¼
Gy
G½
G¾
Gx
Gx
Gx
Gx
5.5
6.6
6.6
9
30
35
32
28
10
13
18
19
5
6.5
9
9.5
7.5
8.3
10
12
20
24
30
37
110
124
149
186
98
112
136
170
23
27
32
42
60.7
70
90
111
46
54
66
84
Ordering data
Designation to VDMA
ISO size
Pneumatic connection
1, 2, 3, 4, 5 12, 14
Weight
[g]
Part No.
Type
VDMA 24345-B-1
VDMA 24345-B-2
VDMA 24345-B-3
VDMA 24345-B-4
1
2
3
4
G¼
Gy
G½
G¾
280
450
660
1,080
9485
11416
10337
152814
NAU-¼-1B-ISO
NAU-y-2B-ISO
NAU½-3B-ISO
NAU-¾-4B-ISO
Gx
Gx
Gx
Gx
-H- Note: This product conforms to ISO 1179-1 and to ISO 228-1
2013/01 – Subject to change
Internet: www.festo.com/catalogue/...
89
Solenoid/pneumatic valves, to ISO 5599-1
Accessories
Ports underneath
Manifold sub-base NAV
Materials:
ISO size 1, 2, 3:
Die-cast aluminium
ISO size 4:
Anodised aluminium
Dimensions 93
General technical data
Conforms to standard
ISO 5599-1
Operating and environmental conditions
ISO size
1
2
Certification
–
UL recognized (OL)
3
4
–
Ordering data
Designation to VDMA
ISO size
Pneumatic connection
2, 4
12, 14
Weight
[g]
Part No.
Type
VDMA 24345-C-1
VDMA 24345-C-2
VDMA 24345-C-3
VDMA 24345-C-4
1
2
3
4
G¼
Gy
G½
G¾
240
400
700
1,400
10173
11305
10175
11139
NAV-¼-1C-ISO
NAV-y-2C-ISO
NAV-½-3C-ISO
NAV-¾-4C-ISO
Gx
Gx
Gx
Gx
Ports at side and underneath
90° connection plate NAW
Materials:
ISO size 1, 2, 3:
Die-cast aluminium
ISO size 4:
Anodised aluminium
Dimensions 93
General technical data
Conforms to standard
ISO 5599-1
ISO 5599-1
Operating and environmental conditions
ISO size
1
Note on materials
Free of copper and PTFE
2
3
4
–
Ordering data
Designation to VDMA
ISO size
Pneumatic connection
2, 4
12, 14
Weight
[g]
Part No.
Type
VDMA 24345-E-1
VDMA 24345-E-2
VDMA 24345-E-3
VDMA 24345-E-4
1
2
3
4
G¼
Gy
G½
G¾
360
600
920
1,550
11304
11307
11309
11141
NAW-¼-1E-ISO
NAW-y-2E-ISO
NAW-½-3E-ISO
NAW-¾-4E-ISO
Gx
Gx
Gx
Gx
-H- Note: This product conforms to ISO 1179-1 and to ISO 228-1
90
Internet: www.festo.com/catalogue/...
Subject to change – 2013/01
Solenoid/pneumatic valves, to ISO 5599-1
Accessories
Manifold sub-base with 90°
connections NAVW
Ports at side and underneath
Materials:
Die-cast aluminium
Dimensions 93
General technical data
Conforms to standard
ISO 5599-1
Ordering data
ISO size
1
2
3
End plate kit NEV
Pneumatic connection
2, 4
12, 14
Weight
[g]
Part No.
Type
G¼
Gy
G½
320
550
1,020
152789
152790
152791
NAVW-¼-1-ISO
NAVW-y-2-ISO
NAVW-½-3-ISO
Gx
Gx
Gx
Materials:
ISO size 1, 2, 3:
Die-cast aluminium
ISO size 4:
Anodised aluminium
Dimensions 93
General technical data
Conforms to standard
ISO 5599-1
ISO 5599-1
Operating and environmental conditions
ISO size
1
Note on materials
Free of copper and PTFE
2
3
4
–
Ordering data
Designation to VDMA
ISO size
Pneumatic connection
1, 3, 5
Weight
[g]
Part No.
Type
VDMA 24345-D-1
VDMA 24345-D-2
VDMA 24345-D-3
VDMA 24345-D-4
1
2
3
4
Gy
G½
G1
G1
280
450
760
1,390
10174
11306
10176
11140
NEV-1DA/DB-ISO
NEV-2DA/DB-ISO
NEV-3DA/DB-ISO
NEV-4DA/DB-ISO
-H- Note: This product conforms to ISO 1179-1 and to ISO 228-1
2013/01 – Subject to change
Internet: www.festo.com/catalogue/...
91
Solenoid/pneumatic valves, to ISO 5599-1
Accessories
Materials:
ISO size 1, 2, 3:
Steel
Blanking plate NDV
ISO size 4:
Wrought aluminium alloy
Dimensions 93
General technical data
Conforms to standard
ISO 5599-1
Operating and environmental conditions
Operating medium
Note on operating/pilot medium
Compressed air according to ISO 8573-1:2010 [7:–:–]
Lubricated operation possible (in which case lubricated operation will always
be required)
Ordering data
ISO size
1
2
3
4
Weight
[g]
Part No.
Type
113
166
314
1,480
9489
11308
10340
11142
NDV-1-ISO
NDV-2-ISO
NDV-3-ISO
NDV-4-ISO
Materials:
Die-cast aluminium
Isolating disc NSC
Dimensions 93
General technical data
Conforms to standard
ISO 5599-1
ISO 5599-1
Operating and environmental conditions
ISO size
1
Note on materials
Free of copper and PTFE
2
3
4
–
Ordering data
ISO size
Pneumatic connection
Weight
[g]
Part No.
Type
1
2
3
4
G¼
Gy
G½
G¾
6
9.2
20
24
11550
11908
11551
11699
NSC-¼-1-ISO
NSC-y-2-ISO
NSC-½-3-ISO
NSC-¾-4-ISO
92
Internet: www.festo.com/catalogue/...
Subject to change – 2013/01
Solenoid/pneumatic valves, to ISO 5599-1
Accessories
Download CAD data www.festo.com
Dimensions – Manifold assembly
1 Left-hand end plate
2 Manifold sub-base NAV
3 Blanking plate NDV
4 Right-hand end plate
5 90° connection plate NAW
6 Port pattern to ISO 5599-1
7 Manifold sub-base with 90°
connections NAVW
8 Isolating disc NSC
ISO size
B1
B2
B3
B4
B5
B6
B7
B8
B9
D1
D2
D3
D4
∅
D5
∅
D6
∅
1
2
3
4
43
56
71
82
22
26
30
30
42
55
70
80
40
50
70
80
11
13
15
15
7.5
6
8
9
1.5
5
6
8
4
6
6
–
21.6
27
35.5
–
G¼
Gy
G½
G¾
Gy
G½
G1
G1
Gx
Gx
Gx
Gx
10
11
15
15
5.5
6.6
9
9
7
9
12
12
ISO size
H1
H2
H3
H4
H5
H6
H7
L1
L2
L3
L4
L5
L6
L7
T1
1
2
3
4
81
85
99
120
46
47
56
58
44
45
54
55
50.5
60
66
–
12.5
15
17.5
–
37
40
45
65
5
5
5
5
110
135
190
215
95
115
168
184
80
96
120
–
28
35
52
56
26
30
38
52
11
15
19
–
11
14
19
–
5.7
6.8
9
9
-H- Note: This product conforms to ISO 1179-1 and to ISO 228-1
2013/01 – Subject to change
Internet: www.festo.com/catalogue/...
93
Solenoid/pneumatic valves, to ISO 5599-1
Accessories
Intermediate plate NZV
For connecting manifold sub-bases of
different sizes
Materials:
Anodised die-cast aluminium
General technical data
Based on standard
Note on materials
ISO 5599-1
Free of copper and PTFE
Download CAD data www.festo.com
Dimensions
Intermediate plates NZV – ISO size 1, 2, 3
1 Left-hand end plate
ISO size 2
2 Manifold sub-base
ISO size 2
3 Intermediate plate
NZV-1-2
4 Manifold sub-base
ISO size 1
5 Right-hand end plate
ISO size 1
NZV-1-2
NZV-3-2/1
Ordering data
For manifold sub-bases ISO size 1 and 2
For manifold sub-bases ISO size 1 and 3 or size 2 and 3
94
Internet: www.festo.com/catalogue/...
Weight
[g]
Part No.
Type
393
473
164940
12911
NZV-1-2
NZV-3-2/1
Subject to change – 2013/01
Solenoid/pneumatic valves, to ISO 5599-1
Accessories
Exhaust air flow control for 3 and 5
Flow control plate GRO
Materials:
Anodised aluminium
General technical data
Based on standard
Integrated function
ISO 5599-1
Flow control valve, non-return valve
Operating and environmental conditions
RoHS-compliant
UL recognized (OL)
Standard nominal flow rate qnN as a function of turns n of the regulating screw
GRO-ZP-1-ISO-B
GRO-ZP-2-ISO-B
GRO-ZP-3-ISO
qnN [l/min]
qnN [l/min]
qnN [l/min]
Note on materials
Certification
n
n
n
Download CAD data www.festo.com
Dimensions
1 Regulating screw for flow
control valve
2 Captive mounting screws
Dimensions and ordering data
ISO size
D1
B1
B2
H1
H2
H3
L1
L2
L3
L4
Weight
[g]
Part No.
Type
1
2
3
28
38
48
25
29
33
6.5
9.5
12
12.5
14.5
16.5
77
100
132
36
48
64
18
24
32
6
6.3
7
230
440
850
151705
151706
119674
GRO-ZP-1-ISO-B
GRO-ZP-2-ISO-B
GRO-ZP-3-ISO
M5
M6
M8
42
54
70
2013/01 – Subject to change
Internet: www.festo.com/catalogue/...
95
Solenoid/pneumatic valves, to ISO 5599-1
Accessories
Materials:
Housing: Die-cast aluminium, steel
Seals: NBR
Intermediate pressure regulator
plate
LR-ZP
General technical data
Conforms to standard
Integrated function
Design
Pressure regulation range
Supply pressure 1
Type of mounting
[bar]
[bar]
Operating and environmental conditions
ISO size
ISO 5599-1
Pressure regulator
Piston
0 … 12
Max. 14
2 through-holes in housing
3
Flow rate qn as a function of output pressure p2
LR-ZP-A-D-1, LR-ZP-B-1,
LR-ZP-P-D-1
LR-ZP-A/B-1
LR-ZP-A-D-2, LR-ZP-B-2,
LR-ZP-A/B-2
LR-ZP-P-D-2
p2 [bar]
p2 [bar]
Certification
p2 [bar]
2
Contains PWIS (paint-wetting impairment substances)
–
–
RoHS-compliant
UL recognized (OL)
p2 [bar]
1
Note on materials
qn [l/min]
LR-ZP-A-D-3, LR-ZP-B-3,
LR-ZP-A/B-3
LR-ZP-P-D-3
p2 [bar]
p2 [bar]
qn [l/min]
qn [l/min]
96
qn [l/min]
qn [l/min]
qn [l/min]
Internet: www.festo.com/catalogue/...
Subject to change – 2013/01
Solenoid/pneumatic valves, to ISO 5599-1
Accessories
Download CAD data www.festo.com
Dimensions
Intermediate pressure regulator plates LR-ZP – ISO size 1, 2, 3
1 Pressure gauge connection
Gx
2 Regulating screw
Regulated port
ISO size 1
1
2
4
2, 4
ISO size 2
1
2
4
2, 4
ISO size 3
1
2
4
2, 4
3 Port pattern to ISO 5599-1
4 Captive mounting screws
5 Rotary knob
B
H
H1
H2
L1
L2
L3
L4
L5
L6
L7
L8
42.6
45
52
8
161
–
161
161
–
–
–
200
209
–
–
–
–
–
322
–
–
209
–
–
48
48
–
–
90
–
90
90
–
90
90
–
54
58
62.5
10
188
–
188
188
–
–
–
233
247
–
–
–
–
–
376
–
–
247
–
–
–
59
–
–
105.5
–
105.5
105.5
–
105.5
105.5
–
70
63
65
14
201.5
201.5
201.5
201.5
–
–
–
260
274
–
–
–
–
–
403
–
–
274
–
–
–
72.5
–
–
119
–
119
119
–
119
119
–
2013/01 – Subject to change
Internet: www.festo.com/catalogue/...
97
Solenoid/pneumatic valves, to ISO 5599-1
Accessories
Ordering data
Regulated port
ISO size
Weight
[g]
Part No.
Type
1
1
520
35966
LR-ZP-P-D-1
2
960
35967
LR-ZP-P-D-2
3
1,220
35968
LR-ZP-P-D-3
1
520
35424
LR-ZP-B-D-1
2
960
35425
LR-ZP-B-D-2
3
1,220
35426
LR-ZP-B-D-3
1
520
35969
LR-ZP-A-D-1
2
960
35970
LR-ZP-A-D-2
3
1,220
35971
LR-ZP-A-D-3
1
840
35427
LR-ZP-A/B-D-1
2
1,490
35428
LR-ZP-A/B-D-2
3
1,770
35429
LR-ZP-A/B-D-3
ISO size
Weight
[g]
Part No.
Type
1, 2, 3
64.5
345395
MA-40-16-x
2
4
2, 4
Ordering data – Accessories
Pressure gauge for intermediate pressure regulator plates LR-ZP
-H- Note: This product conforms to ISO 1179-1 and to ISO 228-1
98
Internet: www.festo.com/catalogue/...
Subject to change – 2013/01
Solenoid/pneumatic valves, to ISO 5599-1
Accessories
Ordering data – Solenoid coils
Voltage
Cable length
[m]
Part No.
Type
F solenoid coils for valves MFH, JMFH
12 V DC
24 V DC and 42 V AC, 50 … 60 Hz
42 V DC
24 V AC
48 V AC, 50 … 60 Hz
110 V AC, 50 … 60 Hz and 120 V AC, 60 Hz
230 V AC, 50 … 60 Hz and 240 V AC, 60 Hz
240 V AC, 50 … 60 Hz
–
–
–
–
–
–
–
–
34410
34411
34413
34415
34418
34420
34422
34424
MSFG-12DC-OD
MSFG-24/42-50/60-OD
MSFG-42DC-OD
MSFG-24AC-OD
MSFW-48AC-OD
MSFW-110AC-OD
MSFW-230AC-OD
MSFW-240AC-OD
N1 solenoid coils for valves MN1H, JMN1H
24 V DC
12 V DC and 24 V AC, 50 … 60 Hz
110 V AC, 50 … 60 Hz
230 V AC, 50 … 60 Hz
–
–
–
–
123060
170152
123061
123062
MSN1G-24DC-OD
MSN1W-24AC/12DC
MSN1W-110AC-OD
MSN1W-230AC-OD
F solenoid coils for valves MFH, JMFH – Explosion-proof to EN 50028
24 V DC
24 V DC
24 V AC, 50 … 60 Hz
110 V AC, 50 … 60 Hz
230 V AC, 50 … 60 Hz
230 V AC, 50 … 60 Hz
1
5
1
1
1
5
535619
535621
535623
535622
535620
535625
MSFG-24DC-EX
MSFG-24DC-EX-K5
MSFW-24AC-EX
MSFW-110AC-EX
MSFW-110AC-EX
MSFW-110AC-EX-K5
2013/01 – Subject to change
Internet: www.festo.com/catalogue/...
99
Solenoid/pneumatic valves, to ISO 5599-1
Accessories
Ordering data – Plug sockets, plug sockets with cable for F solenoid coils
Description
Cable length
[m]
Plug socket without cable
Angled socket, screw terminal, cable connector
Pg9
Angled socket, screw terminal, cable connector
M16
Plug socket without cable
Angled socket, insulation displacement
connector
Plug socket with cable
24 V DC
24 V DC
24 V DC
Up to 240 V
Up to 240 V
Plug socket without cable
Angled socket, insulation displacement
connector
Plug socket with cable
24 V DC
24 V DC
24 V DC
Up to 230 V
Up to 230 V
100
Part No.
Type
–
–
34431
MSSD-F
–
–
59710
MSSD-F-M16
–
–
192746
MSSD-F-S-M16
2.5
5
10
2.5
5
–
–
30935
30937
193458
30936
30938
KMF-1-24DC-2,5-LED
KMF-1-24DC-5-LED
KMF-1-24DC-10-LED
KMF-1-230AC-2,5
KMF-1-230AC-5
Part No.
Type
Ordering data – Plug sockets, plug sockets with cable for N1 and D solenoid coils
Description
Cable length
[m]
Plug socket without cable
Angled socket, screw terminal, cable connector
Pg9
Angled socket, screw terminal, cable connector
M16
Switching status
display via LED
Switching status
display via LED
–
–
34583
MSSD-C
–
–
539709
MSSD-C-M16
–
–
192748
MSSD-C-S-M16
2.5
5
10
2.5
5
–
–
30931
30933
193459
30932
30934
KMC-1-24DC-2,5-LED
KMC-1-24DC-5-LED
KMC-1-24DC-10-LED
KMC-1-230AC-2,5
KMC-1-230AC-5
Internet: www.festo.com/catalogue/...
Subject to change – 2013/01
Solenoid/pneumatic valves, to ISO 5599-1
Accessories
Ordering data – Plug sockets, plug sockets with cable for valves with central plug
Description
Part No.
Type
Plug socket without cable
Angled socket, M12, 4-pin, type A, screw terminal
185498
SEA-M12-4WD-PG7
185499
KM12 M12-GSWD-1-4
Voltage
Part No.
Type
12 … 24 V DC
19143
MF-LD-12-24DC
230 V DC/V AC
19144
MF-LD-230AC
12 … 24 V DC
19145
MC-LD-12-24DC
230 V DC/V AC
19146
MC-LD-230AC
Part No.
Type
Inscription label for valves (24 in frames included in the scope of delivery)
161937
IBS-9x17
Tool for manual override
Valves MEBH
157601
AHB-MEB
Valves MN1H/MFH
157651
AHB-MD/MF/MV
Plug socket with cable
Connecting cable, straight plug, angled socket
Ordering data – Illuminating seal
Description
For F solenoid coils
For N1 solenoid coils
M12, 4-pin, 1.0 m
Ordering data – Accessories
Description
Inscription label
Manual override
2013/01 – Subject to change
Internet: www.festo.com/catalogue/...
101