TRS 5-6 Installation Instructions 810378-03 Temperature Switch Type TRS 5-6 1 Contents Page Important Notes Usage for the intended purpose ...................................................................................... 7 Safety note ...................................................................................................................... 7 Danger ............................................................................................................................ 7 Explanatory Notes Scope of supply .............................................................................................................. 7 System description .......................................................................................................... 8 Function .......................................................................................................................... 8 Technical Data ................................................................................................................. 9 Installation TRS 5-6 b ...................................................................................................................... 10 TRS 5-6 c/d ................................................................................................................... 10 Example of installation .................................................................................................. 15 Wiring TRS 5-6 b, TRS 5-6 c/d .................................................................................................. 11 Adjusting Temperature Limit Example 1 ..................................................................................................................... 12 Example 2 ..................................................................................................................... 12 Example 3 ..................................................................................................................... 12 Commissioning Check wiring .................................................................................................................. 12 Apply mains voltage ...................................................................................................... 12 Check functions ............................................................................................................. 13 Annex Fault finding list for troubleshooting ............................................................................... 13 Declaration of conformity .............................................................................................. 15 2 Wiring Diagram TRS 5-6 b L N 8 9 10 9 Fig. 1 Pt 100 DIN IEC 751 9 L 10 N 8 TRS 5-6 c/d 9 Fig. 2 3 Parts Drawings A 1 2 3 6 5 4 Fig. 3 Fig. 4 D E 158 95 B 37.5 75 C Fig. 5 4 120 5 F Fig. 6 Parts Drawings G 1 5 30 2 4 8 16 32 64 128 256 7 °C 128.5 2 3 7 4 12 TE 1 TE (= division units) ^ 5.08 mm = Fig. 7 Fig. 8 I H yellow red black red Fig. 9 white white Fig. 10 5 Key A Cover screw B Hole for wall mounting C Cable entry D Base E Cover F Mounting clip G Fixing screws for 19" slide-in unit H Resistance thermometer TRG 5-53, TRG 5-55, TRG 5-57 (1 x Pt 100) I Resistance thermometer TRG 5-54, TRG 5-56, TRG 5-58 (2 x Pt 100) 1 Toggle switch TEST 2/ INSPECTION 2 LED ALARM 3 Button TEST 1 4 LED POWER 5 LED TEMPERATURE COEFFICIENT 6 Code switch TRS 5-6 b 7 Code switch TRS 5-6 c/ d (19" slide-in unit) 8 External wire link 9 Protection circuit 10 Mains 6 Important Notes Usage for the intended purpose Temperature switch type TRS 5-6 serves as safety device in plants requiring official approval and is used in conjunction with resistance thermometers types TRG 5-53, TRG 5-54, TRG 5-55, TRG 5-56, TRG 5-57 and TRG 5-58. Use temperature switch only for signalling temperature limits. Safety note Use temperature switch TRS 5-6b, TRS 5-6 c/d only for signalling temperature limits. The equipment must only be installed by qualified staff. Qualified staff are those persons who – through adequate training in electrical engineering, the use and application of safety equipment in accordance with regulations concerning electrical safety systems, and first aid & accident prevention – have achieved a recognised level of competence appropriate to the installation and commissioning of this device. Danger The terminal strip of the TRS 5-6 b, TRS 5-6 c/d is live during operation. This presents the danger of electric shock. Cut off power supply before fixing or removing the cover. Explanatory Notes Scope of supply TRS 5-6 b 1 Temperature switch (plug-in unit in plastic case for installation in control cabinets) 1 Installation manual TRS 5-6 c 1 Temperature switch (19" slide-in unit, front panel acc. to DIN 41494, part 5, 12 TE1) 2 Guide rails 1 Screw-type connector 1 Installation manual TRS 5-6 d 1 Temperature switch (19" slide-in unit, front panel acc. to DIN 41494, part 5, 12 TE1) 1 Installation manual 1 ) TE = division units (1 TE = 5.08 mm) 7 Explanatory Notes – continued – System description Self-monitoring temperature switch with periodic self-checking feature to be used in conjunction with a resistance thermometer type TRG 5-53, TRG 5-54, TRG 5-55, TRG 5-56, TRG 5-57 or TRG 5-58. The equipment operates as a safety temperature controller, or in conjunction with an external lock-out in accordance with VDE 0116 as a safety temperature limiter. An alarm is given as soon as the temperature exceeds a preset limit value. Application in steam boilers and pressurized hot-water plants operating without constant supervision (TRD 604) as well as any other kind of heat generator. Function The temperature switch type TRS 5-6 is a two channel unit provided with an automatic periodic self-checking logic unit, in accordance with DIN 3440/VDE 0116 (regulations for protection circuits for firing equipment of furnaces). The two channels are designed to monitor the operation of each other. If one channel fails, an alarm signal is initiated, simultaneously switching the output contacts to shut off the heat supply. The periodic self-checking logic unit checks the two channel circuits for malfunction. The integrity of the resistance thermometer is continuously monitored by the TRS 5-6. This is done automatically every 40 seconds by the triggering of a test alarm pulse through the circuit. Unless it finds a fault, this internal test does not interfere with the output contacts of the temperature switch and therefore the plant operation is not interrupted. A manual test push button is also provided. When the push button TEST I is pressed, it simulates a fault in the resistance thermometer. There is also a toggle switch TEST II / INSPECTION for checking the function of the self-checking circuitry. The output contact relays of the temperature switch are of the normally closed type and will therefore signal alarm condition in the event of a mains failure. The temperature switch can signal the following three operating conditions: ■ Normal operation (temperature within permissible range) ■ Alarm (limit temperature exceeded) ■ Alarm (fault in temperature switch or resistance thermometer) A green LED indicates mains supply ON. Exceeding of limit temperature or malfunction of the system is indicated by two red LEDs. The failure of one channel (loss of redundancy) is signalled by the lighting-up of one red LED. The combination of resistance thermometer TRG 5-... and temperature switch TRS 5-6 provides fail-safe protection against a first fault, i. e. the system will still continue to provide the safety function even after the occurence of a first fault. 8 Explanatory Notes – continued – Technical Data Type-approval no. DIN · STW (STB) · 985 93S Input 3 terminals for the connection of one resistance thermometer (Pt 100): TRG 5-5..., PN 40 – 160, Tmax 251 °C – 540 °C Output 2 volt-free relay contacts. Max. contact rating with switching voltages of 24 V, 115 V and 230 V a. c.: 4 A resistive, 0.75 A inductive, cos ϕ 0.5. Max. contact rating with a switching voltage of 24 V d. c.: 4 A Contact material silver, hard-gold plated. Temperature range Temperature limits adjustable in steps of 2 °C within a range of 30 °C to 540 °C by a code switch. Switching hysteresis – 3 °C Indicators and adjustors 2 red LEDs ALARM 1 green LED “POWER ON” 1 button TEST I 1 toggle switch TEST II / INSPECTION 8 LEDs and 1 eight-pole code switch for setting the limit temperature. Mains supply 230 V +/– 10 %, 50/60 Hz Special voltage: 115 V +/– 10 %, 50/60 Hz or 24 V +/– 10 %, 50/60 Hz Power consumption 5 VA Protection TRS 5-6 b: IP 20 to DIN EN 60 529 TRS 5-6 c: IP 10 TRS 5-6 d: IP 10 Permissible ambient temperature TRS 5-6 b: 0 – 55 °C TRS 5-6 c: 0 – 70 °C TRS 5-6 d: 0 – 70 °C Case materials TRS 5-6 b: Base: ABS plastic, black. Cover: polystyrene, highly shock-resistant, stone grey. Fig. 5, Fig. 6 TRS 5-6 c: Front panel: Aluminium. Fig. 7 TRS 5-6 d: Front panel: Aluminium. Fig. 7 Weight TRS 5-6 b: approx. 1.0 kg TRS 5-6 c: approx. 0.8 kg TRS 5-6 d: approx. 0.8 kg 9 Installation TRS 5-6 b On supporting rail (with mounting clip) 1. Clip temperature switch onto supporting rail. 2. Loosen cover screws A and unplug cover E from its base 3. Select cable entry C and remove corresponding seal. On mounting panel 1. Loosen cover screws A and unplug cover E from its base 2. Unscrew mounting clip F . 3. Drill the hole B marked in the base to 4.3 mm dia. 4. Fasten base with two M4 screws onto mounting panel. D . D . TRS 5-6 c 1. Mount plastic card guide rail into 19" magazine. 2. Install screw-type connector. 3. Introduce 19" slide-in unit into magazine and fix with screws G . G . TRS 5-6 d 1. Mount plastic card guide rail into 19" magazine. 2. Install screw-type connector. 3. Introduce 19" slide-in unit into magazine and fix with screws Tools ■ Screwdriver (5.5/100) 10 Wiring TRS 5-6 b Use screened four-core supply cable for wiring, e. g. 2 x 2 x 0.8 mm or 4 x 0.5 mm² 1. Connect terminal strip according to wiring diagram. Fig. 1 2. Connect additional display units to terminals marked in yellow and black of the TRG 5-54, TRG 5-56 and TRG 5-58. Fig. 10 TRS 5-6 c/d Use screened four-core supply cable for wiring, e. g. 2 x 2 x 0.8 mm or 4 x 0.5 mm². The external wire link 8 should be fitted on site. 1. Connect terminal strip according to wiring diagram. Fig. 2 2. Connect additional display units to terminals marked in yellow and black of the TRG 5-54, TRG 5-56 and TRG 5-58. Fig. 10 Wiring diagram See wiring diagram on page 3. Attention ■ To protect the switching contacts fuse circuit with T 2.5 A or according to TRD regulations (1.0 A for 72 h operation). ■ The screen must not make any other electrical contact. Note ■ Connect screen only to terminal [13] of the temperature switch TRS 5-6 b or [A22] of the temperature switch TRS 5-6 c/d. ■ The loop resistance must be under 10 Ω. ■ The rated voltage is stated on the name plate. ■ When switching off inductive loads, voltage spikes are produced that may impair the operation of control and measuring systems. Inductive loads should therefore be provided with commercial arc suppressor RC combinations, e. g. 0.1 µF/100 Ω. Tool ■ Screwdriver for slotted screws, size 2.5, completely insulated according to VDE 0680. 11 Adjusting Temperature Limit On the rear of the TRS 5-6 there is a code switch for adjusting the temperature. Example 1 Requested temperature limit τmax = 176 °C. The 8-pole code switch shows values between “2” and “256”. The basic temperature is 30 °C. Set the “2”, “16” and “128” switches to the right using a small screwdriver. The other switches remain in their left hand position. The sum of the three values gives a temperature of 146 °C, plus the basic temperature of 30 °C. This corresponds to the requested temperature limit τmax = 176 °C. Example 2 Requested temperature limit τmax = 446 °C. Set the “32”, “128” and “256” switches to the right using a small screwdriver. The sum of the three values gives a temperature of 416 °C, plus the basic temperature of 30 °C. This corresponds to the requested limit temperature τmax = 446 °C. Example 3 Requested temperature limit τmax = 79 °C. Set the “16” and “32” switches to the right using a small screwdriver. The sum of the two values gives a temperature of 46 °C, plus the basic temperature of 30 °C. This corresponds to a limit temperature τmax = 78 °C. An adjustment of 79 °C is not possible as temperatures can only be adjusted in steps of 2 °C. Tool ■ Screwdriver for slotted screws, size 2.5, completely insulated according to VDE 0680. Commissioning Check wiring Check whether the TRS 5-6 has been wired to its associated system components TRG 5-... according to the wiring diagram. Fig. 1, Fig. 2, Fig. 9, Fig. 10 Apply mains voltage Switch on power supply. The LED 12 4 will be illuminated. Fig. 3, Fig. 7 Commissioning – continued – Check functions TRS 5-6 b, TRS 5-6 c/d 1. When switching on the mains voltage the green LED 4 should be permantently illuminated. Fig. 3 2. Raise temperature in heat generator until the permissible temperature limit is exceeded. The two red LEDs 2 on the temperature switch must light up. 3. After lowering the temperature the two red LEDs must extinguish. 4. An alarm ‘limit temperature exceeded’ can be simulated by pushing the button TEST I 3 . On pushing the button the two red LEDs must light up. 5. To check the function of the self-checking circuitry of the temperature switch proceed as follows: Set switch TEST II / INSPECTION 1 in the direction of the arrow. After max. two minutes the two red LEDs 2 should signal alarm. The button TEST I 3 must not be operated during this test nor must the adjusted limit temperature be exceeded. After the test return switch 1 into its original position. After the response delay the two red LEDs must extinguish. Annex Danger The terminal strip of the TRS 5-6 b, TRS 5-6 c/d is live during operation. This presents the danger of electric shock. Cut off power supply before fixing or removing the cover. Fault finding list for troubleshooting Fault: The temperature switch signals alarm during normal operation (temperature within permissible limits). Remedy 1: Check whether the green LED 4 is illuminated, if not, check power supply. Remedy 2: Check whether resistance thermometer supply cable is damaged. Remedy 3: Check whether measured values emitted by resistance thermometer are correct (basic values of precision resistors in accordance with DIN 43760 for Pt 100). Fault: Remedy: The testing with the switch TEST II / INSPECTION 1 was not successful, i. e. only one or neither of the red LEDs 2 illuminates within two minutes from the start of the test. Replace temperature switch. If faults occur that are not listed above please contact our subsidiary or agency in your country. 13 Annex – continued – Declaration of Conformity We hereby declare that the equipment TRS 5-6 b and TRS 5-6 c/d conform to the following European guidelines: ■ LVD guideline 73/23/eec version 93/68/eec ■ EMC guideline 89/336/eec version 93/68/eec which are based on the following harmonised standards: ■ LV standard EN 50 178 ■ EMC standard EN 50 081-2, EN 50 082-2 This declaration is no longer valid if modifications are made to the equipment without consultation with us. Bremen, 12 th June 2001 GESTRA GmbH Head of the Design Dept. Lars Bohl Academically qualified engineer Academically qualified engineer Key A Cover screw B Hole for wall mounting C Cable entry D Base E Cover J Mounting rail TS 35 x 15 to DIN EN 50022 14 Quality Assurance Representative Uwe Bledschun Example of Installation E D C E J A Fig. 11 B B Fig. 12 15 GESTRA Gesellschaften · GESTRA Companies · Sociétés GESTRA · Sociedades Gestra · Società GESTRA Vertretungen weltweit · Agencies all over the world · Représentations dans le monde entier · Representaciones en todo el mundo · Agenzie in tutto il mondo Great Britain Italia Flowserve Flow Control (UK) Ltd. Flowserve S.p. A Burrel Road, Haywards Heath West Sussex RH 16 1TL Tel. 00 44 14 44 / 31 44 00 Fax 00 44 14 44 / 31 45 40 E-mail: [email protected] Divisione Italgestra Via Prealpi, 30 – 20032 Cormano (MI) Tel. 00 39 02 / 66 32 51 Fax 00 39 02 / 66 32 55 60 E-mail: [email protected] France Portugal Flowserve Flow Control S. A. S. Flowserve Portuguesa, Lda. 10 Avenue du Centaure, BP 8263 F-95801 CERGY PONTOISE CEDEX Tél. 0 03 31 / 34 43 26 60 Fax 0 03 31 / 34 43 26 87 E-mail: [email protected] Av. Dr. Antunes Guimarães, 1159 Porto 4100-082 Tel. 00351 22 / 6 19 87 70 Fax 00351 22 / 6 10 75 75 E-mail: [email protected] España GESTRA ESPAÑOLA S.A. Luis Cabrera, 86-88 E-28002 Madrid Tel. 00 34 91 / 5 152 032 Fax 00 34 91 / 4 136 747; 5 152 036 E-mail: [email protected] ® GESTRA GmbH P. O. Box 10 54 60, D-28054 Bremen, Münchener Str. 77, D-28215 Bremen Telephone +49 (0) 421 35 03 - 0, Fax +49 (0) 421 35 03 - 393 E-Mail [email protected], Internet www.gestra.de A Unit of Flowserve Corporation 810378-03/903c · © 1998 GESTRA GmbH · Bremen · Printed in Germany 16
© Copyright 2026 Paperzz