2 Wavelength Integrating Nephelometer The Ambilabs dual wavelength nephelometer is a robust ambient airquality instrument designed to provide measurements of particle concentrations, ambient visibility, and source apportionment information. The unit includes an LCD display to provide information about measured parameters, flow rate, instrument status and power. An active heating system which is controlled based on relative humidity levels warms the sample air and sample cell to keep the RH below a set point to avoid particle growth with humidity. Additional features include a purge air system and an automatic zero calibration routine. The instrument can be installed in any ambient shelter or monitoring facility. The Ambilabs dual wavelength nephelometer determines particulate concentration by measuring the total scatter from aerosols using a selectable wavelength, while both wavelengths are used to determine the scattering Ångström exponent which is inversely related to particle size in the sample air, showing basically the average (mode) diameter of the measured particle size distribution. While the time series of the scattering coefficient already represents the measured particle concentration, the Ambilabs dual wavelength nephelometer has a separate output for a PMestimate based on a user selectable calibration with measurement range of 0 to 100 mg/cubic meter or 0 to 100,000 ug/ cubic meter. Optional sharp-cut cyclones can be used to select the sample flow for PM1, PM2.5, or PM10 size fractions. BENEFITS: Example of Ångström Exponent Usage (above): On 6/23/15, the Ångström Exponent (green) decreases, revealing the coarse particle influence from a Sahara Dust event in Atlanta, GA. Collocated PM measurements show a corresponding increase in PM10 concentration (yellow). The red scattering coefficient (635 nm) follows mostly the PM2.5 concentration and can be scaled with a user defined factor to get a PM2.5 estimate. The 1 minute Nephelometer data show the exceptional time resolution of the instrument. The noise level for 1 minute values is smaller than the noise level of the hourly PM measurements (FEM particulate comparison monitor), indicating the outstanding precision of the nephelometer. NOTE: Instrument also performs automated, internal quality control via a built-in zero check feature every 24 hours (as represented in the above graph). [email protected] (401) 247-0100 Easy automatic calibration with cost effective (low grade) CO2 gas ensures repeatability of measurement Automatic optical reference calibration High powered LED light source increases measurement accuracy Single light source and detector used for all wavelengths Facilitates a wide measuring range (0 to 20,000 Mm⁻¹) Compact and portable QA parameters available like “cleaning indicator” (wall count) and “lamp intesity drift” (shutter count) Internal sample heater with temperature or RH control, which can be enabled by the user to eliminates effects of humidity RH: <30% to <90% Fully automatic zero check or adjust, automatic span check or automatic zero and span check available in intervals of 1, 3, 6, 12, 24 hours or weekly Fully integrated package including: internal sample pump, sample heater, internal calibration valves, zero air pump, and data logger Low power internal 12V sample heater Long lasting LED light source Very low cost of ownership SPECIFICATIONS: Measured Parameters: Ranges: Lower Detectable Limit: Secondary Measurements: Intensity Function: Flow Rate: Operating Temperature: Operating RH: Calibration: Optics: Light Source: Wavelength: Operating Voltage: Dimensions: Weight: Light scattering coefficient (σSP) at 2 user selectable wavelengths from built-in 3 wavelength light source (450, 525, and 635 nm) 0.0 to >20,000Mmˉ¹ <0.3Mmˉ¹ (60 second averaged data) Sample air temperature, chassis temperature, relative humidity, and sample pressure Full scatter 9-170° 5 l/min nominal (not controlled) -20 to 45°C 10 to 95% Span gas selection and calibration values for CO2, SF6, FM-200, R-12, R-134, or a user defined gas Reference brightness shutter Stable LED light source 525nm (green), 450nm (blue), and 635nm (red) [only 2 can be operated at one time] 12 VDC (including 110-240 VAC 50/60 Hz power converter) [60 watts with heater active] 6.7” x 27.5” x 8.5” (L x W x H) 24.7 lbs. COMMUNICATIONS/ DATA LOGGING: Outputs: Filtering: Stored Parameters: Capacity: 4 analog outputs (2 voltage and 2 current) and 2 x RS232 serial ports Kalman (digital adaptive filter), moving average (30 seconds), or no filter Date and time, 2 x σSP (635, 525, or 450 selectable), PMestimate, Ångström exponent, air temp, enclosure temp, RH, pressure, status At least 33 days of 5 minute averages, or 6 days of 1 minute averaged data OPTIONS: APPLICATIONS: External pump control Naphion Dryer inlet to avoid losses of volatile particles Solar power panels and batteries Roof flange kit and rain cap with insect screen Gas calibration kit and wall mount bracket Measurements of light scattering Air Quality Index/PMestimate Source apportionment Ångström exponent calculations Smoke monitoring Ambient dust monitoring Industrial process measurements Clean rooms [email protected] (401) 247-0100
© Copyright 2026 Paperzz