DATA SHEET R-Series RSC Replacement Self-Contained ADVANTAGES Compact and lightweight sections for simplified entry into existing buildings. igh efficiency H refrigeration system for reduced operational costs. Low sound operation using direct-drive fans and a 2" foaminjected cabinet. The Innovent RSC product line can All units ship in multiple sections be used to directly replace vertical with a maximum size of 78" high x self-contained units buried deep in 60" long x 34" wide for simplified the heart of existing buildings. The entry into the building through product line was specifically designed multiple locations (doors, elevators, to replace the Trane SWUA product floor hatches, louvers, etc.). Each series, but can be applied to most section weighs less than 1,400 other self-contained units. The pounds to simplify hoisting and Innovent RSC was designed for maneuvering through the building. ease of installation, industry-leading Multiple fans and compressors efficiency and quiet operation. are provided for redundancy and simplified stocking of spare parts. 40, 50 and 60 ton models ship in 8 sections as displayed here. 20, 25 and 30 ton models ship in 4 sections. DATA SHEET R-Series RSC Replacement Self-Contained RSC Sizing Chart Model: RSC-20 RSC-25 RSC-30 RSC-40 RSC-50 RSC-60 Cooling Capacity: 20 tons 25 tons 30 tons 40 tons 50 tons 60 tons Unit Height: 78" 78" 78" 91" 91" 91" Unit Length: 88" 88" 110” 110" 120" 120" Unit Width*: 68" 68" 68" 68" 68" 68" Quantity of Sections: 4 4 4 8 8 8 *Includes a waterside economizer coil. Does not include the “bolt-on” filter rack, heating or mixing box modules. Standard Features: Optional Features: • 2" R12 foam-injected double wall panels • Waterside economizer coil with or without • G90 galvanized interior and exterior walls • Perforated liner in the fan discharge section • Single-piece fully intertwined DX coil with stainless steel drain pan • Multiple direct drive plenum fans with single VFD •Removable panels for easy component access and minimal clearance requirements • One digital and one fixed-speed scroll compressor on models RSC-20, 25 & 30 cleanable plugs, removable header or control valves • Variable speed or digital lead compressor •Head pressure control valves shipped loose for field installation •Painted exterior (Innovent gray color) • Hinged access doors • Heating “bolt-on” modules (electric, hot water or steam coils) and two fixed-speed tandem compressors • Mixing box “bolt-on” module on models RSC-40, 50 & 60 • 4" MERV 13 filtration • Cleanable shell & tube condensers • 2" MERV 8 side access filter rack • BACnet, Lonworks or Modbus BMS connectivity • DDC controller with remote user display • VAV or CO2 control sequences • Unit EERs are 14.5 or higher • Extended compressor warranty • Top or front supply duct connections • Factory start-up and/or owner • All units are ETL listed Bringing the outside in. www.innoventair.com INV-DS-01 January 2013 training services For more information, contact Innovent: 60 28th Avenue North Minneapolis, MN 55411 [email protected] Innovent is a business of Unison Comfort Technologies | unisoncomfort.com Phone 612.877.4800 Fax 612.877.4801
© Copyright 2026 Paperzz