here

DATA SHEET
R-Series RSC
Replacement Self-Contained
ADVANTAGES
Compact and
lightweight sections
for simplified entry
into existing buildings.
igh efficiency
H
refrigeration
system for reduced
operational costs.
Low sound operation
using direct-drive
fans and a 2" foaminjected cabinet.
The Innovent RSC product line can
All units ship in multiple sections
be used to directly replace vertical
with a maximum size of 78" high x
self-contained units buried deep in
60" long x 34" wide for simplified
the heart of existing buildings. The
entry into the building through
product line was specifically designed
multiple locations (doors, elevators,
to replace the Trane SWUA product
floor hatches, louvers, etc.). Each
series, but can be applied to most
section weighs less than 1,400
other self-contained units. The
pounds to simplify hoisting and
Innovent RSC was designed for
maneuvering through the building.
ease of installation, industry-leading
Multiple fans and compressors
efficiency and quiet operation.
are provided for redundancy and
simplified stocking of spare parts.
40, 50 and 60 ton
models ship in
8 sections as
displayed here.
20, 25 and 30 ton
models ship in
4 sections.
DATA SHEET
R-Series RSC Replacement Self-Contained
RSC Sizing Chart
Model:
RSC-20
RSC-25
RSC-30
RSC-40
RSC-50
RSC-60
Cooling Capacity:
20 tons
25 tons
30 tons
40 tons
50 tons
60 tons
Unit Height:
78"
78"
78"
91"
91"
91"
Unit Length:
88"
88"
110”
110"
120"
120"
Unit Width*:
68"
68"
68"
68"
68"
68"
Quantity of Sections:
4
4
4
8
8
8
*Includes a waterside economizer coil. Does not include the “bolt-on” filter rack, heating or mixing box modules.
Standard Features:
Optional Features:
• 2" R12 foam-injected double wall panels
• Waterside economizer coil with or without
• G90 galvanized interior and exterior walls
• Perforated liner in the fan discharge section
• Single-piece fully intertwined DX coil with
stainless steel drain pan
• Multiple direct drive plenum fans with single VFD
•Removable panels for easy component access
and minimal clearance requirements
• One digital and one fixed-speed scroll
compressor on models RSC-20, 25 & 30
cleanable plugs, removable header or
control valves
• Variable speed or digital lead compressor
•Head pressure control valves shipped loose
for field installation
•Painted exterior (Innovent gray color)
• Hinged access doors
• Heating “bolt-on” modules (electric,
hot water or steam coils)
and two fixed-speed tandem compressors
• Mixing box “bolt-on” module
on models RSC-40, 50 & 60
• 4" MERV 13 filtration
• Cleanable shell & tube condensers
• 2" MERV 8 side access filter rack
• BACnet, Lonworks or Modbus
BMS connectivity
• DDC controller with remote user display
• VAV or CO2 control sequences
• Unit EERs are 14.5 or higher
• Extended compressor warranty
• Top or front supply duct connections
• Factory start-up and/or owner
• All units are ETL listed
Bringing the outside in.
www.innoventair.com
INV-DS-01
January 2013
training services
For more information,
contact Innovent:
60 28th Avenue North
Minneapolis, MN 55411
[email protected]
Innovent is a business of Unison Comfort Technologies | unisoncomfort.com
Phone 612.877.4800
Fax 612.877.4801