Section A

Cables And Equipment
Mining * Construction * Shipping * Manufacturing * Lighting & Entertainment
Power Cables*Festoon Systems*Conductor Systems*Connectors*Cable Reelers
High Voltage Couplers*Spring Reels*Grounding Reels*Fixed Power Cables
Fibre Cables*Data Accessories*Glands*Manufactured Leads*Tools*Slip Rings
Conveyor Monitoring Equipment*Auto Cables*Gaffa Reels*VSD Cables
Aflex
Cables
Noremak Industries
General Product Catalogue 2009-2010
Noremak Industries Pty Ltd
12 Princess Street Beverley SA 5009 PH: 08 8244 7288 Fax 08 8244 7299 email:[email protected]
Section A Flex Power Cables
re
ma
k
Contents
Single Double Insulated 110 EPR/CPE Flexible 0.6/1kV
A1
Single Double Insulated R 90 Elastomer 0.6/1kV
A2
Single Double Insulated 110 EPR/CPE 1.9/3.3kV Tinned
A3
Single Double Insulated R90 EPR/CPE 0.6/1kV Screened
A4
Single Insulated 90 C 0.6/1kV Flexible Earth Cables
A5
Single Insulated R180 C 0.6/1kV Tinned Silicon
A6
Single Insulated V90 HT PVC 0.6-1Kv Tinned Conductor
A7
Multi Core R 90C NBR/NBR 0.6/1kV And 300/500v
Multi Core R 90 C EPR/CPE 0.6/1kV And 300/500v Tinned Conductor
A8, A9
A10, A11
A12
Multi Core Control V 90 C PVC/NBR 300/500v (White Numbered Cores)
A13
Multi Core Control V 90 C PVC/PVC 300/500v (Black Numbered Cores)
A14
Multi Core Control V 90 C PVC/PVC 300/500v Screened (Black Numbered Cores)
A15
Multi Core R 90 C NBR/NBR 0.6/1kV Steel Braided
A16
Twin V75 C NBR/TPE 0.6/1kV Flex Figure 8
A17
No
Multi Core X 90 C XLPE/NBR And EPR/CPE Screened VSD
Multi Core R 90 C EPR/PUR 0.6/1kV And 300/500v
Technical Information
A18, A19
A20 To A25
A1
Flexible Power Cables
0
110 C RATED
0
Single, Double Insulated 110 Deg
Flexible Cable 0.6/1.0Kv
LOW SMOKE
HALOGEN FREE
Temperature Range:
re
ma
k
Cable Construction
*-30 to + 110 degrees C static -20 to +90 degrees C
flexible
* Conductors of extra fine wires to
international standards to ensure maximum
flexibility.
* Insulation allows conductor temperature of
110 degrees C and is extremely flexible
* Special jacket of outstanding toughness and
flexibility, resistance to acid, solvents and
oil at extreme temperatures
* UV stabilised and flame retardant
Rated Voltage:
* 0.6/1Kv Relevant Standards: * VDE 0250, AS 3116,
AS 1995, IEC 332-3
Maximum Conductor Temperature:
* 110 Degrees C
Bending Radius Fixed:
* 5 times diameter of the cable
Available Colors:
HALOGEN FREE
Part No
16
25
35
50
70
95
120
150
185
240
300
400
500
Stranding
470/0.20
726/0.20
1040/0.20
1499/0.20
2165/0.20
2745/0.20
1544/0.30
1961/0.30
2331/0.30
3172/0.30
3965/0.30
5246/0.30
6588/0.30
Overall
Dia mm
9.30
10.80
12.10
13.70
15.50
17.90
19.80
22.10
24.40
27.10
29.90
33.50
37.20
No
777500163OR
777500253OR
777500353OR
777500503OR
777500703OR
777500953OR
777501203OR
777051503OR
777501853OR
777502403OR
777503003OR
777504003OR
777505003OR
Size
mm2
***Orange***
Weight
Kg/Km
Nominal
Current Single
phase
@ 40 Deg C
* Hole Size
Bootlace
Pins
Uninsulated
Ferrules
130
175
220
265
340
420
490
570
660
790
910
1070
1250
CL16-*BM
CL25-*BM
CL35-*BM
CL50-*BM
CL70-*BM
CL95-*BM
CL120-*BM
CL150-*BM
CL185-*BM
CL240-*BM
CL300-*BM
CL400-*BM
-
PBL16
PBL25
PBL35
PBL50
PBL70
PBL95
PBL120
-
202
293
390
535
725
870
1205
1500
1840
2350
2915
3817
4805
Bellmouth
Lug
Quick Reference
Cable Technical Information Page 20-22
Current Carrying Capacities Fixed Applications Page 24
Lugs Page F1
Gland Options F8, F9 & F10
A1
A2
Flexible Power Cables
0
90 C RATED
Single, Double Insulated
Flexible Cable 0.6/1.0Kv
Temperature Range:
* Conductors of extra fine wires to
international standards to ensure maximum
flexibility.
* Insulation allows conductor temperature of
90 degrees C and is extremely flexible
NBR Elastomer
* Special jacket of outstanding toughness and
flexibility, resistance to acid, solvents and
oil at extreme temperatures [see detailed
properties chart of NBR Elastomer]
* UV stabilised and flame retardant.
*-30 to + 90 degrees C static -20 to +90 degrees
C flexible
Part No
Cross
Sectional
Area mm
Square
Approx
No: of Wires
Stranding
6
10
16
25
35
50
70
95
120
150
185
240
300
400
172/0.21
304/0.21
462/0.21
742/0.21
1050/0.21
1482/0.21
2090/0.21
2812/0.21
1480/0.31
1887/0.31
2294/0.31
3034/0.31
3811/0.31
5246/0.31
Max
Overall
Dia mm
No
777500061
777500101
777500161
777500251
777500351
777500501
777500701
777500951
777501201
777051501
777501851
777502401
777503001
777504001
re
ma
k
Cable Construction
8.50
9.50
10.80
12.50
13.50
15.50
17.50
20.00
22.00
24.50
27.00
30.00
34.00
39.00
Rated Voltage:
* 0.6/1Kv Relevant Standards: * VDE 0250, AS
3116, AS 1995, IEC 332-3
Maximum Conductor Temperature:
* 90 Degrees C
Bending Radius Fixed:
* 5 times diameter of the cable
Available Colors:
***Orange, Black, Red, & Blue ***
***Add to Part No When Ordering***
Weight
Kg/Km
118
172
231
350
451
605
810
1075
1332
1654
2060
2576
3213
4200
Nominal
Current Single
phase
@ 40 Deg C
* Hole Size
Bootlace
Pins
Uninsulated
Ferrules
59
81
110
145
180
220
280
350
410
470
550
660
770
900
CL6-*BM
CL10-*BM
CL16-*BM
CL25-*BM
CL35-*BM
CL50-*BM
CL70-*BM
CL95-*BM
CL120-*BM
CL150-*BM
CL185-*BM
CL240-*BM
CL300-*BM
CL400-*BM
PBL06
PBL10
PBL16
PBL25
PBL35
PBL50
PBL70
PBL95
PBL120
-
Quick Reference
Cable Technical Information Page 20-22
Current Carrying Capacities Fixed Applications Page 23
Lugs Page F1
Gland Options F8, F9 & F10
Bellmouth
Lug
A3
Flexible Power Cables
0
110 C RATED
re
ma
k
Single, Double Insulated
Flexible Cable
EPR/CPE 1.9/3.3Kv
Temperature Range:
*-40 to + 110 degrees C static -20 to +90
* Tinned Stranded Conductors According to degrees C flexible
Rated Voltage:
VDE 0295 Class 5
* 1.9/3.3Kv Relevant Standards: * VDE 0250
* EPR Rubber Insulation Type 3G13
Part 602, AS 3116, AS3008, AS1125 Maximim
* CPE Rubber Outer Sheath
Conductor Temperature:
* UV stablised and flame retardant.
* 110 Degrees C
* Resistant to oil and abrasion
Bending Radius:
* Submersible to 100 Mts
* 4 times diameter of the cable Static 6 Times
TYPICAL USES:
Flexing
Available Colours:
Power Switchboards, flexible droppers from * Black
bus bars, generators, load banks or
Quick Reference
anywhere SingleDouble insulated flexible
cables are recommended
Cable Technical Information Page 20-22
Battery leads, wiring looms,
Automotive
Current Carrying Capacities Fixed Applications Page 24
Lugs Page F1
battery chargers, electric fork lifts.
Gland Options F8, F9 & F10
Leads, Earth & Power.
Welding
Cable Construction
Part No
1.5
2.5
4.0
6.0
10.0
16.0
25.0
35.0
50.0
70.0
95.0
120.0
150.0
185.0
240.0
300.0
400.0
500.0
Approx
No: of
Wires
Max Dia
mm
Max
Overall
Dia mm
30/0.25
50/0.25
56/0.30
84/0.30
80/0.40
126/0.40
196/0.40
276/0.40
396/0.40
540/0.40
715/0.40
920/0.40
1138/0.40
1390/0.40
1838/0.40
2275/0.40
3035/0.40
3795/.040
6.0
6.2
6.7
7.3
8.6
10.1
12.3
13.0
15.0
16.8
19.7
20.8
23.6
25.7
27.6
31.4
34.4
43.2
No
777633105
777633205
77763304
77763306
77763310
77763316
77763325
77763335
77763350
77763370
77763395
777633120
777633150
777633185
777633240
777633300
777633400
777633500
Cross
Sectional
Area mm
Square
Nominal
Current
Weight
Spaced
Kg/km
@ 40 Deg C
31
43
57
73
99
130
175
220
265
340
420
490
570
660
790
910
1070
1250
65
80
95
120
180
250
350
455
610
805
1055
1350
1655
1975
2550
3230
4222
5200
Bell Mouth
Lug
Part No
* Hole Size
Bootlace
Pins
Uninsulated
Ferrules
CL6-*BM
CL10-*BM
CL16-*BM
CL25-*BM
CL35-*BM
CL50-*BM
CL70-*BM
CL95-*BM
CL120-*BM
CL150-*BM
CL185-*BM
CL240-*BM
CL300-*BM
CL400BM
PBL15
PBL025
PBL04
PBL06
PBL10
PBL16
PBL25
PBL35
PBL50
PBL70
PBL95
PBL120
-
A1
A4
Flexible Power Cables
re
ma
k
Screened EPR/CPE
Variable Speed Drive
SDI Flexible
Maximum Conductor Typical Uses
The cable is designed primarily
Temperature
Cable Construction
for large Variable Speed Drives
and because of the dual
screening gives maximum EMV
protection
+90C
*Flexible tinned annealed copper
Short Circuit 250C
conductors, insulation EPR type IEP3
equivalent to 3G13 according to DIN VDE
Temperature Range
0207 Part 20.
-30C to +90C Flexing
*Tinned Copper Braid screened min 80% -40C to +90C Fixed
plus aluminium / mylar tape. Separator
polyester tape. Outer Sheath CPE
Bending Radius
elastomer
10 x Cable Dia Fixed
12 x Cable Dia Flexing
*UV stabilised and flame retardant
Part No
120
150
185
240
Approx
Max
No: of Wires Overall
Max Dia mm Dia mm
960/0.40
1200/0.40
1470/0.40
1870.0.40
No
777801120SC
777801150SC
777801185SC
777801240SC
Cross
Sectional
Area mm
Square
23.0
26.0
28.0
31.5
Nominal
Current
Spaced
@ 40 Deg C
Weight
Kg/km
410
470
550
660
1460
1774
2170
2798
Bell Mouth
Lugs
EMC
Approved
Metal Gland
* Hole Size
CL120-*BM
CL150-*BM
CL185-*BM
CL240-*BM
Quick Reference
Cable Technical Information Page 20-22
Current Carrying Capacities Fixed Applications Page 23
Lugs Page F1
Gland Options F8, F9 & F10
CABLE PROBLEMS?
NOREMAK INDUSTRIES FOR:
CABLE SOLUTIONS
PHONE:(08)8244 7288 FAX:(08)8244 7299
[email protected]
MG40EMCL
MG40EMCL
MG50EMCL
MG50EMCL
A5
Flexible Power Cables
re
ma
k
Single Insulated Flexible
Earth Cable
TPE 0.6/1kV
Cable Construction
Temperature Range
*
Conductors of extra fine wires to international
standards to ensure maximum flexibility.
Static - 30 to + 90 degree C
Flexible -20 to + 90 degree C
*
Insulation allows conductor temperatures of 90
degree C & is extremely flexible special TPE
compound.
Typical Uses
*
UV stabilised & flame retardant
Part
No
Cross
Sectional
area mm
square
Approx
No of Wires
Max Dia mm
Nominal
overall
Dia mm
Weight
Kg/Km
6
10
16
25
35
50
70
95
120
150
300
84/0.30
128/0.30
196/0.30
308/0.30
434/0.30
608/0.30
874/0.30
1178/0.30
1480/0.30
1887/0.30
3811/0.30
4.8
6.4
7.7
9.5
10.6
12.5
14.8
17.0
18.5
21.0
29.7
109
155
220
325
430
590
800
1040
1300
1500
2950
No
77710006
77710010
77710016
77710025
77710035
77710050
77710070
77710095
77710120
77710150
77710300
Power: Switchboards, Flexible droppers
from busbars flexible links, transformers,
generators, load banks, or anywhere
green/yellow flexible earth cables are to
be used. Welding earth leads.
Lugs
* Hole Size
Quick Reference
Lugs Page F1
Gland Options F8, F9 & F10
CL6-*BM
CL10-*BM
CL16-*BM
CL25-*BM
CL35-*BM
CL50-*BM
CL70-*BM
CL95-*BM
CL120-*BM
CL150-*BM
CL300-*BM
Bootlace
Pins
Uninsulated
Ferrules
PBL06
PBL10
PBL16
PBL25
PBL35
PBL50
PBL70
PBL95
PBL120
-
A7
Flexible Power Cables
Noremak
Cable Construction
re
ma
k
Single Insulated V90 HT
PVC Flexible Cables
0.6-1Kv Rated Tinned Copper
Cores
Max0 Conductor Temperature
Typical Uses
Available Colours
Internal Wiring of
Electronic equipment,
Switchboards
Control panels
+90 C
* Tinned copper conductors
* Insulation V90 HT PVC
* Manufactured in accordance
with AS3191 Or AS3178
Part
No
0.50
0.75
1.00
1.50
2.50
4.00
6.00
Approx
Nominal
Insulation
overall No of Wires Thickness
Dia mm Max Dia mm
2.60
2.80
3.00
3.20
3.90
5.40
5.50
No
4271C16020**
4271C24020**
4271C32020**
4271C30025**
4271C50025**
4271C56030**
4271C84030**
Cross
Sectional
area mm
square
Red, Blue, Black, Yellow,
White Brown, Violet, Orange
Pink, Grey, Green
Green/Yellow Other Cables Available On
Request
16/0.20
24/0.20
32/0.20
30/0.25
50/0.25
56/0.30
84/0.30
0.80
0.80
0.80
0.80
0.90
1.00
1.00
Quick Reference
Current Capacities Page A21
Lug Options F4
Insulated Un-Insulated
Ring
Ring
Terminal
Terminal
* Hole Size * Hole Size
TRRD-*DG
TRRD-*DG
TRBU-*DG
TRBU-*DG
TRY-*DG
TRY-*DG
TRY-*DG
TRU05-*DG
TRU07-*DG
TRU10-*DG
TRU15-*DG
TRU25-*DG
TRU04-*DG
TRU06-*DG
A1
Flexible Power Cables
0
re
ma
k
Single Insulated 180
Silicon Flexible Cables
Cable Construction
Maximum Conductor
Temperature
* Tinned copper conductors, all
Class 5 Stranding.
+180C
Short Term 220C
*
Silicon Insulation tear and
heat resistant Compound
Temperature Range
*
Typical Uses
Static - 60 to + 180 degree C
Flexible -40 to + 180 degree C
Short Term 220C
UV stabilised & Flame
Retardant
Electric signs and
connections
Motor Appliances
Heavy Industry
Medical Areas
Ship and Railway Building
Foundry Switch Boards
Bending Radius
4 x Cable Dia Fixed
Colours Available
2
2
0.75mm To 1.5mm: Earth, Black, Brown, Yellow, Grey, Blue, Orange, Red, Violet, White
2
2.5mm: Earth, Black, Blue, Red, White
2
2
4.0mm To 25.0mm: Red, Black
Part
No
Nominal
overall
Dia mm
Weight
Kg/Km
Un-Insulated
Lugs
* Hole Size
Insulated
Ring
Terminals
* Hole Size
0.75
1.0
1.5
2.5
4.0
6.0
10.0
16.0
25.0
2.4
2.5
2.8
3.4
4.2
5.2
6.4
8.0
10.0
13.3
15.9
21.9
34.7
54.4
82.3
131.9
209.1
326.7
CL1.5-*
CL1.5-*
CL2.5-*
CL4.0-*
CL6.0-*
CL10-*
CL16-*
CL25-*
TRRD-*DG
TRRD-*DG
TRBU-*DG
TRBU-*DG
TRY-*DG
TRY-*DG
-
No
777S01075
777S01010
777S01015
777S01025
777S01040
777S01060
777S01010
777S01016
777S01250
Cross
Sectional
area mm
square
Quick Reference
Lugs Page F1 & F4
Gland Options F8, F9 & F10
A6
A1
Flexible Power Cables
Noremak
re
ma
k
PVC Flexible Multi Core Cables
Ordinary And Heavy Duty
V90-HT
OD Multi Core Flex 250V/440V
Part
No
No: of Cores
&
mm square
Stranding
Nominal
overall
Dia mm
Insulation
Thickness
PVC2C75OD**
PVC3C75OD**
PVC4C75OD**
PVC5C75OD**
2 x 0.75
3 x 0.75
4 x 0.75
5 x 0.75
24/0.20
24/0.20
24/0.20
24/0.20
6.40
6.80
7.30
8.20
0.6
0.6
0.6
0.6
2 x 1.0
3 x 1.0
4 x 1.0
5 x 1.0
32/0.20
32/0.20
32/0.20
32/0.20
6.70
7.00
7.80
8.60
0.6
0.6
0.6
0.6
Black, Red, Orange, White
Grey Blue
2 x 1.5
3 x 1.5
4 x 1.5
5 x 1.5
30/0.25
30/0.25
30/0.25
30/0.25
7.70
8.10
9.10
10.20
0.7
0.7
0.7
0.7
Voltage Rating
250/440V
3 x 2.5
4 x 2.5
5 x 1.5
50/0.25
50/0.25
50/0.25
10.00
11.00
12.40
0.8
0.8
0.8
3 x 4.0
4 x 4.0
5 x 4.0
56/0.30
56/0.30
56/0.30
11.40
12.50
13.80
0.8
0.8
0.8
Available Colours
PVC2C01OD**
PVC3C01OD**
PVC4C01OD**
PVC5C01OD**
PVC2C15OD**
PVC3C15OD**
PVC4C15OD**
PVC5C15OD**
PVC3C25OD**
PVC4C25OD**
PVC5C25OD**
PVC3C04OD**
PVC4C04OD**
PVC5C04OD**
Standards
AS3191
HD Multi Core Flex 0.6/1Kv
No: of Cores
&
mm square
Stranding
Nominal
overall
Dia mm
Insulation
Thickness
PVC2C75HD**
PVC3C75HD**
PVC4C75HD**
PVC5C75HD**
2 x 0.75
3 x 0.75
4 x 0.75
5 x 0.75
24/0.20
24/0.20
24/0.20
24/0.20
8.20
8.80
9.70
10.70
1.30
1.40
1.50
1.60
PVC2C01HD**
PVC3C01HD**
PVC4C01HD**
PVC5C01HD**
2 x 1.0
3 x 1.0
4 x 1.0
5 x 1.0
32/0.20
32/0.20
32/0.20
32/0.20
8.50
9.00
10.00
11.00
1.30
1.40
1.50
1.60
PVC3C15HD**
PVC4C15HD**
PVC5C15HD**
3 x 1.5
4 x 1.5
5 x 1.5
30/0.25
30/0.25
30/0.25
10.00
11.00
12.20
1.60
1.70
1.80
PVC3C25HD**
PVC4C25HD**
PVC5C25HD**
3 x 2.5
4 x 2.5
5 x 1.5
50/0.25
50/0.25
50/0.25
12.00
13.00
14.40
1.80
1.90
2.00
PVC3C04HD**
PVC4C04HD**
PVC5C04HD**
3 x 4.0
4 x 4.0
5 x 4.0
56/0.30
56/0.30
56/0.30
13.90
15.30
17.00
1.90
2.00
2.20
No
Part
No
Available Colours
**Add To Part No
Black, Red, Orange, White
Grey Blue
Voltage Rating
0.6/1Kv
Standards
AS3191
A8
A9
Flexible Power Cables
Silicon Multi Core
Flexible Cables
re
ma
k
Low Smoke Halogen Free
Cable Construction
*
*
*
Tinned copper conductors, all
Class 5 stranding.
Silicon Insulation tear and heat
resistant compound
Working Temperature
0
Typical Uses
0
-60 C To +180 C
Electric Motor Applications
Power Supplies
Medical Areas
Railway And Shipping
Rated Voltage
450/750V
Low Smoke Halogen Free
OD Multi Core Flex 250V/440V
Part
No
Stranding
Nominal
overall
Dia mm
Cable
Weight
Kg/Km
3 X 0.75
4 X 0.75
2 X 1.0
3 X 1.0
4 X 1.0
5 X 1.0
3 X 1.5
4 X 1.5
5 X 1.5
7 X 1.5
12 X 1.5
19 X 1.5
3 X 2.5
4 X 2.5
5 X 2.5
4 X 4.0
4 X 6.0
24/0.20
24/0.20
32/0.20
32/0.20
32/0.20
32/0.20
30/0.25
30/0.25
30/0.25
30/0.25
30/0.25
30/0.25
50/0.25
50/0.25
50/0.25
56/0.30
84/0.30
6.80
7.80
6.60
7.40
8.10
8.80
8.00
8.80
9.60
10.40
14.60
17.00
9.70
10.60
11.60
13.20
15.60
76.0
101.0
76.0
93.0
113.0
133.0
117.0
145.0
175.0
220.0
413.0
591.0
179.0
222.0
268.0
346.0
497.0
No
777S0375
777S0475
777S0201
777S0301
777S0401
777S0501
777S0315
777S0415
777S0515
777S0715
777S1215
777S1915
777S0325
777S0425
777S0525
777S0404
777S0406
No: of Cores
&
mm square
A1
A10
Flexible Power Cables
Cable Construction
re
ma
k
NBR Rubber Elastomer Insulated and
Sheathed High Flex Power and
Control Cables
Heavy Duty 0.6/1kV
Ordinary Duty 250/440V
Temperature Range
*Conductors: annealed fine wires of plain electrolytic copper stranded for
high flexibility.
*Insulation of special flame retardant NBR Elastomer compound formulated
for high flexibility & durable operation in extreme temperatures.
*Separator or bedding of extruded or taped NBR material. Silicated powder
lubricant between cores & inner sheath to reduce friction.
*NBR Elastomer for outstanding flexibility & durability in most hostile
environments.
*UV Stabilised & fire retardant.
-30 to +90 degree C static
-20 to +90 degree C flexible
Bending Radius
5 times diameter - fixed
6 times diameter - flexible
Rated Voltage
O.D.250/440V HD 0.6/1kV
Maximum Conductor Temperature
90 degree C
Relevant Standards
Quick Reference
AS3147, AS3191, IEC227, IEC332.1
AS3008.1.1 1998 Table 13 Fixed, Table 15 Flexing
Pages 31, 34
Applications
Current Capacities Page A21
Gland Options F8, F9 & F10
In machine tools, construction & engineering equipment, conveyors & other industrial application where
outstanding flexibility is required under tough climatic & mechanical conditions. Diesel powered generator sets,
load banks, ship to shore cables.
No
OD Multi Core Flex Orange 250V/440V
Part
No
77700201OR
77700301OR
77700315OR
77700325OR
77700401OR
77700415OR
77700425OR
77700525OR
No: of
Stranding
Cores
&
mm square
2 x 1.0
3 x 1.0
3 x 1.5
3 x 2.5
4 x 1.0
4 x 1.5
4 x 2.5
5 x 2.5
32/0.21
32/0.21
48/0.21
80/0.21
32/0.21
48/0.21
80/0.21
80/0.21
Nominal Weight
overall Kg/Km
Dia mm
6.8
7.4
8.4
10.0
8.0
9.2
11.2
12.5
70
80
105
160
100
130
200
240
Nominal Nylon Gland Metal Gland
Amps
Part No
Part No
Protected
IP66
from Sun
10
10
15
20
10
15
20
20
NGM16
NGM16
NGM16
NGM20
NGM16
NGM20
NGM20
NGM25
MG20-S
MG20-S
MG20-S
MG20-S
MG20-S
MG20-S
MG20
MG20
IP68 Glands Also Available
A11
Flexible Power Cables
NBR Rubber Elastomer Insulated and Sheathed High Flex
Power and Control Cables
Heavy Duty 0.6/1kV
Ordinary Duty 250/440V
Heavy Duty Multi Core Flex 0.6/1kV
No: of
Stranding
Cores
&
mm square
Nominal
Overall
Dia mm
Weight
Kg/Km
Nominal
Amps
Protected
fromSun
Nylon Gland Metal Gland
Part No
Part No
IP66
32/0.21
32/0.21
32/0.21
9.8
10.5
11.6
90
100
130
10
10
10
NGM20
NGM20
NGM20
MG20-S
MG20-S
MG20
48/0.21
48/0.21
48/0.21
48/0.21
48/0.21
10.5
11.6
13.0
15.0
16.7
140
170
210
268
425
15
15
15
15
15
NGM20
NGM20
NGM25
NGM32
NGM32
MG20-S
MG20
MG20
MG25
MG25
80/0.21
80/0.21
80/0.81
80/0.21
80/0.21
80/0.21
12.4
14.0
15.4
15.8
19.2
25.4
194
239
289
365
589
785
20
20
20
20
20
20
NGM25
NGM25
NGM25
NGM25
NGM32
NGM40
MG20-S
MG25
MG25
MG25
MG25
MG32
127/0.21
127/0.21
127/0.21
127/0.21
127/0.21
13.7
14.4
16.0
17.4
20.0
275
319
394
482
600
25
25
25
25
25
NGM25
NGM25
NGM25
NGM32
NGM32
MG25
MG25
MG25
MG25
MG2
190/0.21
190/0.21
190/0.21
15.9
19.0
21.0
406
505
619
46
46
46
NGM25
NGM32
NGM32
MG25
MG32
MG32
re
ma
k
Part
No
3 x 1.0
4 x 1.0
5 x 1.0
77700315
77700415
77700515
77700715
77701215
3 x 1.5
4 x 1.5
5 x 1.5
7 x 1.5
12 x 1.5
77700325
77700425
77700525
77700725
77701225
77701825
3 x 2.5
4 x 2.5
5 x 2.5
7 x 2.5
12 x 2.5
18 x 2.5
77700204
77700304
77700404
77700504
77700704
2x4
3x4
4x4
5x4
7x4
77700306
77700406
77700506
3x6
4x6
5x6
77700310
77700410
77700510
3 x 10
4 x 10
5 x 10
318/0.21
318/0.21
318/0.21
23.7
25.8
28.1
803
975
1190
63
63
63
NGM40
NGM40
NGM50
MG32
MG32
MG40
77700316
77700416
77700516
3 x 16
4 x 16
5 x 16
504/0.21
504/0.21
504/0.21
26.0
28.6
31.7
1040
1285
1590
85
85
85
NGM40
NGM50
NGM50
MG40
MG40
MG40
No
77700301
77700401
77700501
Black Standard Orange Available On Request
Cable Technical Information Page A20, A21 & A22
Gland Options F8, F9 & F10
Voltage Drop Figures Page A22
IP68 Glands Also Available
A1
A12
Flexible Power Cables
Cable Construction
re
ma
k
Flexible Submersible
Harmonised Rubber Sheathed Cables
VDE Approved
Properties [cont]
*Copper conductors [tinned up to 16 sq mm],acc.to VDE
0295, CLASS 5;
*PETP-tape [only for sections above 16 sq,mm]
*EPR rubber insulation type E14 acc. to HD22;
*Elastomeric outer sheath type EM2 acc to HD222
* Oil resistant
* Resistant to environmental factors like oxidation, ozone, sunlight
* Flame retardant
* Very good behavior to variations of outdoor temperature
Voltage Rating
Operating Temperature
*Minimum permissible ambient temperature - 40
degrees Cel
*Maximum permissible short circuit temperature
250 degrees Cel
*Minimum ambient temperature for optimum fully
flexible operations - 25 degrees C
* Rated Voltage UO/U = 0.6/1kv
* Maximum operating voltages in: 3 phase AC Operation UO/U =
0.7/1.15kV
DC operation
UO/U=0.9/1.73kV
* The cable is designated 450/750V with E14 insulation compound in
accordance with VDE/IEC and meets or exceeds the Australian
Standards AS3116 for the voltage rating of 0.6/1kV, R-EP-90
Minimum Bending Radii
Applications
The following minimum bending radius should be observed
to ensure operating reliability.
* For fixed installation - 4 x cable Diameter
* When freely flexing
- 5 x cable Diameter
* For drag chains & reels - 10x cable Diameter
* For medium level mechanical loads, for use in dry & damp locations,
for outdoor use or in locations subject to explosion hazards,
* For industrial & workshop equipment
* For connections of mobile machines & engines on construction sites,
* As fixed installation, for example as installation on plaster in
temporary buildings
Properties
Colour Code
* Good tensile strength, tearing strength & abrasion
resistance
* Good elongation at breaks
* Good dialectical properties * Acid resistant
* 2 conductors : Brown-Blue
* 3 conductors : Brown-Blue-Green/Yellow
* 4 conductors : Grey-Black-Brown-Green/Yellow
* 5 conductors : Grey-Black-Brown-Blue-Green/Yellow
*Submersible to 100 Mtr
No
HO5RN-F 300/500v
Part
No
77711275H05
77711201H05
777113G75H05
777113G1H05
777114G75H05
No Cores Stranding Nominal
&
Overall
MM Square
Dia mm
2 x 0.75
2 x 1.0
3 x 0.75
3 x 1.0
4 x 0.75
0.21
0.21
0.21
0.21
0.21
6.4
7.1
7.0
8.5
8.8
Weight
Kg/Km
78
94
94
114
90
Maximum Nylon
Amps
Gland
Protected Part No
from Sun
12
18
12
18
12
Quick Reference
Current Capacities Page A21
Gland Options Page F8, F9 And F10
Metal
Gland
IP66
Metal
Gland
IP68
NGM16 MG20-16 MGS16
NGM16 MG20-16 MGS16
NGM16 MG20-16 MGS16
NGM16 MG20-S MGS16
NGM16 MG20-S MGS16
A13
Flexible Power Cables
Flexible Submersible
Harmonised Rubber Sheathed Cables
VDE Approved
HO7RN-F 0.6-1Kv
No of cores Max Dia
& size
of Strands
mm sq
mm
Overall Dia
Weight
Kg/Km
Max allowable
current under
permanent
conditions
40deg Cel
Amps
Nylon
Gland
Part No
Metal
Gland
IP66
Metal Gland
IP68
re
ma
k
Part
No
0.21
0.26
0.26
0.31
0.31
0.41
0.41
9.4
9.4
11.5
13.0
14.5
19.5
22.0
100
130
190
260
350
620
850
18
24
34
45
57
78
105
NGM16
NGM16
NGM20
NGM25
NGM25
NGM32
NGM32
MG20-S
MG20-S
MG20
MG25
MG25
MG32
MG32
MGS20
MGS20
MGS20
MGS25
MGS25
MGS32
MGS40
0.21
0.26
0.26
0.31
0.31
0.41
0.41
0.41
9.10
10.10
12.0
14.0
15.5
21.0
24.0
29.0
125
160
230
320
425
765
1060
1560
18
24
34
45
57
78
105
140
NGM20
NGM20
NGM20
NGM25
NGM25
NGM32
NGM40
NGM50
MG20-S
MG20-S
MG20
MG25
MG25
MG32
MG32
MG40
MGS20
MGS20
MGS20
MGS25
MGS25
MGS40
MGS40
MGS50
4 x 1.0
4 x 1.5
4 x 2.5
4 x 4.0
4 x 6.0
4 x 10.0
4 x 16.0
4 x 25.0
4 x 35.0
4 x 50.0
4 x 70.0
4 x 95.0
4 x 120.0
0.21
0.26
0.26
0.31
0.31
0.41
0.41
0.41
0.41
0.41
0.51
0.51
0.51
10.0
11.50
13.50
15.50
17.50
23.0
26.0
32.0
35.0
40.0
45.0
51.0
56.0
155
200
290
400
540
930
1300
1950
2330
3200
4200
5490
7098
16
20
28
38
48
66
88
120
145
180
230
285
330
NGM20
NGM20
NGM25
NGM25
NGM32
NGM40
NGM40
NGM50
NGM63
NGM63
-
MG20-S
MG20
MG25
MG25
MG25
MG32
MG40
MG50-S
MG50-S
MG50
MG63-S
MG63
MG63
MGS20
MGS20
MGS25
MGS25
MGS32
MGS40
MGS40
MGS50
MGS63
MGS63
777115g1
777115G15
777115G025
777115G4
777115G6
777115G10
777115G16
777115G25
777115G35
777115G50
777115G70
777115G95
5 x 1.0
5 x 1.5
5 x 2.5
5 x 4.0
5 x 6.0
5 x 10.0
5 x 16.0
5 x 25.0
5 x 35.0
5 x 50.0
5 x 70.0
5 x 95.0
0.21
0.26
0.26
0.31
0.31
0.41
0.41
0.41
0.41
0.41
0.51
0.51
11.5
12.5
15.0
17.0
19.0
25.0
29.0
35.0
39.0
45.0
50.0
56.6
190
240
350
500
670
1140
1610
2440
2900
4000
5250
6780
16
20
28
38
48
66
88
120
145
180
230
285
NGM20
NGM25
NGM25
NGM32
NGM32
NGM40
NGM50
NGM63
NGM63
-
MG20
MG20
MG25
MG25
MG25
MG32
MG40
MG50-S
MG50
MG63S
MG63
-
MGS20
MGS20
MGS25
MGS32
MGS32
MGS40
MGS50
MGS63
MGS63
-
777117G15
777117G25
777117G4
777117G6
777117G10
7 x 1.5
7 x 2.5
7 x 4.0
7 x 6.0
7 x 10
0.26
0.26
0.31
0.31
0.41
16.0
18.50
21.50
24.80
29.50
330
470
660
956
1494
13
18
22
31
41
NGM25
NGM32
NGM32
NGM40
NGM50
MG25
MG25
MG32
MG32
MG40
MGS32
MGS32
MGS40
MGS40
MGS50
777112G15
777112G25
12 x 1.5
12 x 2.5
0.26
0.26
19.0
22.50
480
690
13
18
NGM32
NGM40
MG32
MG32
MGS32
MGS40
777118G15
777118G25
18 x 1.5
18 x 2.5
0.26
0.26
22.0
26.50
690
1010
13
18
NGM32
NGM40
MG32
MG40
MGS40
MGS40
7771127G15
7771127G25
7771137G15
27 x 1.5
27 x 2.5
37 x 1.5
0.26
0.26
0.26
28.10
33.50
30.10
1102
1521
1310
13
18
13
NGM50
NGM50
NGM50
MG40
MG50-S
MG40
MGS50
MGS50
MGS50
2 x 1.0
2 x 1.5
2 x 2.5
2 x 4.0
2 x 6.0
2 x 10.0
2 x 16.0
777113G1
777113G15
777113G25
777113G4
777113G6
777113G10
777113G16
777113G025
3 x 1.0
3 x 1.5
3 x 2.5
3 x 4.0
3 x 6.0
3 x 10.0
3 x 16.0
3 x 25.0
777114G1
777114G15
777114G25
777114G4
777114G6
777114G10
777114G16
777114G025
777114G35
777114G50
777114G70
777114G95
77114G120
No
77711201
77711215
77711225
77711240
77711260
77711210
77711216
-
A1
Flexible Power Cables
XLPE/NBR 90C 0.6/1Kv
Screened Flexible
Variable Speed Drive Cable
*
Rated Voltage
re
ma
k
Cable Construction
0.6/1Kv
Conductors of extra fine bare annealed
copper wires.
Insulation
Relevant Standards
AS3147, IEC332-1
Maximum Conductor Temperature
XLPE 90 Deg C
-30 to +90 degree C
Screening
Colour
Aluminium/Maylar tape plus tinned copper
braid up to 4.0mm, above is tinned copper
braid
Sheath
Black / Clear To 35.0mm
Black Only Over 35.0mm
Bending Radius
Clear Sheath is TPE 1.5mm to 35.0mm
Back Sheath NBR to 6.0mm and CPE
10.0mm and above
Fixed >20.0mm 7.5x diam<20.0mm 10x Cable
diam
Flexing>20.0mm 15xcable diam <20.0mm x 20
cable diam
UV Stabilised and Flame Retardant
AS 3008.1.1 1998 Table 13 Fixed Table 15 Flexing
Cross
Sectional
area mm
square
77780315SC
77780325SC
77780415SC
77780425SC
77780404SC
77780406SC
77780410SC
77780416SC
777804025SC
77780435SC
77780450SC
77780470SC
77780495SC
777804120SC
777804150SC
77780525SC
77780506SC
1.5
2.5
1.5
2.5
4.0
6.0
10.0
16.0
25.0
35.0
50.0
70.0
95.0
120.0
150.0
2.5
6.0
Power
Cores
Earth
Cores
Nominal
overall
Dia mm
Weight
Kg/Km
Amps
Spaced
EMC Compliant
Metal
Gland
2x1.5
2x2.5
3x1.5
3x2.5
3x4.0
3x6.0
3x10.0
3x16.0
3x25.0
3x35.0
3x50.0
3x70.0
3x95.0
3x120.0
3x150.0
4x2.5
4x6.0
1x1.5
1x2.5
1x1.5
1x2.5
1x4.0
3x1.5
3x1.5
3x2.5
3x4.0
3x6.0
3x10.0
3x10.0
3x16.0
3x16.0
3x25.0
1x2.5
1x6.0
12.5
13.5
13.5
14.5
16.5
19.5
21.5
23.5
28.5
32.0
40.0
43.3
48.7
51.3
58.5
18.7
21.0
155
195
195
245
350
445
675
955
1455
2200
3211
3950
5126
5925
7146
533
952
24
34
20
28
38
48
66
88
120
145
180
230
285
330
375
28
48
MG20EMCL
MG25EMCL
MG25EMCL
MG25EMCL
MG25EMCL
MG32EMCL
MG40EMCL
MG40EMCL
MG50EMCL
MG50EMCL
MG63EMCL
No
Part
No
Please Refer to Noremak
For More Information On
Larger Sizes And Options
MG32EMCL
MG40EMCL
Please refer to Australian Standards for full conditions and notes which refer to this table
Quick Reference
Current Capacities Page A21
Gland Options Page F9
A14
A15
Flexible Power Cables
Flexible Control PVC/NBR 0.3/0.5kV
Cable Construction
PVC Insulated
re
ma
k
*Conductors annealed fine wires of
plain electrolytic copper stranded for
high flexibility.
Part
No
Cores: white insulated with
sequential black numbers,
1green/yellow
Protective sheath of flame retardant
NBR Elastomer for outstanding
flexibility & durability in most hostile
environments.
UV stabilised & flame retardant
Screening if applicable will be tinned
copper braid. 85% minimum
coverage. Suitable for protection
against EMI Radiation
Temperature Range
Static - 30 to + 80 degree C
Flexing -5 to + 70 degree C
Rated Voltage
300/500 votls
Relevant Standards
VDE 0295 class 5 [ conductor] VDE
0812 [cores] IEC 332-1
Maximum Conductor Temperature
90 degree C
No
Bending Radius For flexing
application:
15 times diameter unscreened
20 times diameter screened
Applications
As power control or signal cables on
machines, portable tools, conveying
equipment & similar industrial
applications.
No of Cores Approx O.D.
Section
mm
mm square
Approx
Weight
Kg/Km
Nylon
Gland
Metal
Gland
IP66
77720205
77720305
77720405
77720505
77720705
77721205
77721805
77722505
77723005
77724105
2 x 0.5
3 x 0.5
4 x 0.5
5 x 0.5
7 x 0.5
12 x 0.5
18 x 0.5
25 x 0.5
30 x 0.5
41 x 0.5
4.8
5.1
5.7
6.6
7.0
9.4
11.1
12.4
13.3
16.6
35
42
54
67
84
131
192
261
304
450
NGM12
NGM12
NGM16
NGM16
NGM16
NGM20
NGM20
NGM25
NGM25
NGM25
MG20-16
MG20-16
MG20-16
MG20-16
MG20-S
MG20-S
MG20
MG20
MG25
MG25
77720375
77720475
77720575
77720775
77721275
77721875
77722575
3 x 0.75
4 x 0.75
5 x 0.75
7 x 0.75
12 x 0.75
18 x 0.75
25 x 0.75
6.0
6.2
7.1
7.6
10.6
12.2
14.3
66
88
100
161
247
268
465
NGM16
NGM16
NGM16
NGM16
NGM20
NGM25
NGM25
MG20-16
MG20-16
MG20-16
MG20-16
MG20-S
MG20
MG25
77720301
77720401
77720501
77720701
77721201
77721801
77722501
77723601
77724101
3 x 1.0
4 x 1.0
5 x 1.0
7 x 1.0
12 x 1.0
18 x 1.0
25 x 1.0
36 x 1.0
41 x 1.0
6.0
6.5
7.6
8.0
11.1
13.4
15.4
18.2
18.8
65
79
105
131
220
315
449
620
660
NGM16
NGM16
NGM16
NGM16
NGM20
NGM25
NGM25
NGM32
NGM32
MG20-16
MG20-16
MG20-16
MG20-S
MG20
MG25
MG25
MG25
MG25
77720215
77720315
77720415
77720515
77720715
77721215
77721815
77721915
77722515
77723015
77723715
77725015
2 x 1.5
3 x 1.5
4 x 1.5
5 x 1.5
7 x 1.5
12 x 1.5
18 x 1.5
19 x 1.5
25 x 1.5
30 x 1.5
37 x 1.5
50 x 1.5
8.5
6.7
8.3
9.1
9.7
13.4
16.2
16.5
19.5
20.5
22.0
26.0
84
117
121
144
237
393
465
542
655
750
980
1224
NGM16
NGM16
NGM16
NGM20
NGM20
NGM25
NGM25
NGM32
NGM32
NGM32
NGM40
NGM40
MG20-S
MG20-S
MG20-S
MG20-S
MG20-S
MG25
MG25
MG25
MG32
MG32
MG32
MG40
77720425
77720725
77721225
77721825
77722725
4 x 2.5
7 x 2.5
12 x 2.5
18 x 2.5
27 x 2.5
11.0
13.0
17.5
21.0
25.0
192
310
524
784
900
NGM20
NGM25
NGM32
NGM32
NGM40
MG20
MG25
MG25
MG32
MG40
Quick Reference
Current Capacities Page A20
Multi Core Deratings A21
Gland Options Page F8, F9 And F10
A1
A16
Flexible Power Cables
Flexible Control PVC/PVC 0.3/0.5Kv
Cable Construction
wires of plain electrolytic copper
stranded for high flexibility.
*PVC Insulated
No of Cores Approx Approx
Section
O.D.
Weight
mm square
mm
Kg/Km
Nylon
Gland
Metal
Gland
IP66
re
ma
k
Part No
*Conductors annealed fine
*Cores: Black insulated with
sequential white numbers, Plus
1 green/yellow
*Protective sheath of flame
retardant PVC for outstanding
flexibility & durability in most
hostile environments.
*UV stabilised & flame retardant
Temperature Range
*Static - 30 to + 80 degree C
*Flexing -5 to + 70 degree C
Relevant Standards
VDE 0295 class 5 [ conductor]
VDE 0812 [cores] IEC 332-1
3 x 0.50
4 x 0.50
5 x 0.50
7 x 0.50
12 x 0.50
18 x 0.50
25 x 0.50
5.1
5.7
6.2
6.7
8.9
10.5
12.5
42
54
63
81
131
188
261
NGM12
NGM16
NGM16
NGM16
NGM16
NGM20
NGM20
MG20-16
MG20-16
MG20-16
MG20-16
MG20-S
MG20-S
MG20
77720375P
77720475P
77720575P
77720775P
77721275P
77721875P
77722575P
3 x 0.75
4 x 0.75
5 x 0.75
7 x 0.75
12 x 0.75
18 x 0.75
25 x 0.75
5.7
6.2
6.7
7.3
10
11.8
13.8
55
66
79
101
171
244
337
NGM12
NGM16
NGM16
NGM16
NGM20
NGM20
NGM25
MG20-16
MG20-16
MG20-16
MG20-16
MG20-S
MG20
MG25
77720301P
77720401P
77720501P
77720701P
77721201P
77721801P
77722501P
3 x 1.0
4 x 1.0
5 x 1.0
7 x 1.0
12 x 1.0
18 x 1.0
25 x 1.0
6.0
6.5
7.1
8.0
10.5
12.7
14.7
65
79
94
126
205
300
408
NGM16
NGM16
NGM16
NGM16
NGM20
NGM25
NGM25
MG20-16
MG20-16
MG20-16
MG20-S
MG20-S
MG20
MG25
77720315P
77720415P
77720515P
77720715P
77721215P
77721815P
77722515P
3 x 1.5
4 x 1.5
5 x 1.5
7 x 1.5
12 x 1.5
18 x 1.5
25 x 1.5
6.7
7.2
8.1
9.0
12
14.4
17.0
84
104
128
166
279
407
560
NGM16
NGM16
NGM16
NGM16
NGM20
NGM25
NGM32
MG20-16
MG20-16
MG20-S
MG20-S
MG20
MG25
MG25
77721225P
77721825P
12 x 2.5
18 x 2.5
17.5
21.0
445
648
NGM32
NGM32
MG25
MG32
No
Maximum Conductor
Temperature
77720305P
77720405P
77720505P
77720705P
77721205P
77721805P
77722505P
90 degree C
Bending Radius For flexing
application:
15 times diameter unscreened
Applications
As power control or signal
cables on machines, portable
tools, conveying equipment &
similar industrial applications.
Quick Reference
Current Capacities Page A20
Multi Core Deratings A21
Gland Options Page F8, F9 And F10
A17
Flexible Power Cables
Flexible Control PVC Screened
0.3/0.5Kv
Static - 30 to + 70 degree C
Flexing -5 to + 70 degree C
Rated Voltage
300/500 votls
test voltage 2000 V
Approx O.D.
mm
EMC
Compliant
Gland
77720205SC
77720305SC
77720405SC
77720505SC
77720705SC
77721205SC
77721805SC
77722505SC
77723005SC
2 x0.5
3 x 0.5
4 x 0.5
5 x 0.5
7 x 0.5
12 x 0.5
18 x 0.5
25 x 0.5
30 x 0.5
7.0
7.3
7.9
8.4
8.9
11.3
13.3
15.2
16.1
MG16EMCL
MG16EMCL
MG16EMCL
MG16EMCL
MG16EMCL
MG20EMCL
MG25EMCL
MG25EMCL
MG25EMCL
77720475SC
77720575SC
77720775SC
77721275SC
77721875SC
77722575SC
4 x 0.75
5 x 0.75
7 x 0.75
12 x 0.75
18 x 0.75
25 x 0.75
8.4
8.9
9.7
12.3
14.5
16.6
MG16EMCL
MG16EMCL
MG20EMCL
MG20EMCL
MG25EMCL
MG25EMCL
77720301SC
77720401SC
77720501SC
77720701SC
77721201SC
77721801SC
77722501SC
77723401SC
77724101SC
3 x 1.0
4 x 1.0
5 x 1.0
7 x 1.0
12 x 1.0
18 x 1.0
25 x 1.0
34 x 1.0
41 x 1.0
8.2
8.7
9.5
10.2
13.3
15.5
17.5
20.3
22.0
MG16EMCL
MG16EMCL
MG20EMCL
MG20EMCL
MG25EMCL
MG25EMCL
MG32EMCL
MG32EMCL
MG40EMCL
77720215SC
77720315SC
77720415SC
77720515SC
77720715SC
77721215SC
77721815SC
77722515SC
77723415SC
77725015SC
2 x 1.5
3 x 1.5
4 x 1.5
5 x 1.5
7 x 1.5
12 x 1.5
18 x 1.5
25 x 1.5
34 x 1.5
50 x 1.5
8.5
8.9
9.6
10.3
11.3
14.8
17.2
20.1
22.8
27.1
MG16EMCL
MG20EMCL
MG20EMCL
MG20EMCL
MG20EMCL
MG25EMCL
MG32EMCL
MG32EMCL
MG40EMCL
MG40EMCL
77720425SC
77720725SC
77721225SC
4 x 2.5
7 x 2.5
12 x 2.5
11.3
13.9
17.6
MG20EMCL
MG25EMCL
MG32EMCL
re
ma
k
*Fine wires Strands of bare copper
wire, PVC core insulation, cores
twisted in layers, black with
consecutive numbering in white.
One green yellow earth core.
Outer sheath of PVC Compound
Temperature Range
No of Cores
Section mm
Square
Part No
Cable Construction
Conductor Stranding
No
Fine Wire to VDE0295 and IEC
60228
Quick Reference
Current Capacities Page A20
Multi Core De-ratings A21
Gland Options Page F9
A1
Flexible Power Cables
re
ma
k
Flexible Steel Braided Flexible Cable
0.6/1kV
CABLE CONSTRUCTION
TEMPERATURE RANGE:
*Conductor fine wire strands of
plain electrolytic copper wire for
improved flexibility.
* - 30 TO + 90 Degree C static
*Insulation made of NBR
elastomer compound specially
designed for resistance to
migration & cold flexibility.
RATED VOLTAGE
*0.6/1Kv
*Inner sheath of specially
formulated PVC, resistant to
migration & highly flexibile in subzero temperatures.
AS3147,IEC92-3,IEC92-353,IEC92350,
IEC332-3
*Silicate powder lubricant
between cores & inner sheath to
reduce friction
* - 18 TO + 90 Degree C flexible
RELEVANT STANDARDS
BENDING RADIUS
15 X DIAMETER
APPLICATIONS
Quick Reference
No
Current Capacities Page A21
Gland Options Page F9-F10
As power, control or signal cable on
inland waterway & sea-going vessels.
On conveyors, machine tools, cranes,
earth moving equipment & other
industrial applications where extra
mechanical protection is required. Also
suitable for wiring in hazardous
locations [i.e chemical plants]
Part
No
No of Cores x
Section mm
square
Stranding
Approx
Outer Dia
mm
Approx
Weight
Kg/Km
Metal Gland
SWA Type
77770315
77770415
77770515
77770715
77771215
3x1.5
4x1.5
5x1.5
7x1.5
12x1.5
48/0.21
48/0.21
48/0.21
48/0.21
48/0.21
12.8
13.6
14.5
15.7
18.0
220
261
271
330
504
MGSWA20-16
MGSWA20-S
MGSWA20-S
MGSWA20
MGSWA20
77770325
77770425
77770725
3x2.5
4x2.5
7x2.5
80/0.21
80/0.21
80/0.21
14.2
15.2
17.5
260
295
448
MGSWA20-S
MGSWA20-S
MGSWA20
A18
A19
Flexible Power Cables
Parallel Twin Flexible Cable
0.6/1kV
Temperature Range:
*Conductors of fine strands of
Rated Voltage:
re
ma
k
Cable Construction
*-30 to + 75 degrees C static
-20 to +75 degrees C flexible
electrolytic copper wire for extra
flexibility.
* 0.6/1Kv fixed wiring
450/750v for flexing
*Insulation of cores in red/black or
Red/ Blue Aflex NBR elastomer
Relevant Standards:
* VDE 0250, VDE472, AS3147, IEC
332-1
*Compound specially formulated
for improved cold resistance.
Application:
*Sheathing of transparent PVC
compound resistant to cold,
abrasion, industrial oil and
chemicals
* Battery cable for use indoors and
outdoors, in dry as well as wet
locations on motorised vehicles, or
battery powered equipment such as
fork lifts, field conveyors etc. Also in
high quality booster cables.
*UV stabilised and flame retardant
No Of Cores
x mm Sq
Stranding
Approx
Overall
Dia. mm
Bootlace
Pins Uninsulated
Ferrules
Bellmouth
Lug
* Hole Size
77760225
77760204
77760206
77760210
77760216
77760225
77760235
77760250
77760270
2x 2.5mm
2 x 4.0mm
2 x 6.0mm
2 x 10.0mm
2 x 16.0mm
2 x 25.0mm
2 x 35.0mm
2 x 50.0mm
2 x70.0mm
80/0.21
127/0.21
190/0.21
318/0.21
504/0.21
770/0.21
1083/0.21
1558/0.21
2204/0.21
5.5x12
6.0x13
6.5x14
8.0x17
9.0x19
11.0x23
12.5x26
14.5x30
16.0x33
PBL025
PBL04
PBL06
PBL10
PBL16
PBL25
PBL35
PBL50
PBL70
CL025-*
CL6-*
CL6-*BM
CL10-*BM
CL16-*BM
CL25-*BM
CL35-*BM
CL50-*BM
CL70-*BM
No
Part
No
Quick Reference
Current Capacities Page A21
Gland Options Page F8, F9, F10
A1
A20
Flexible Power Cables
HO5 BQ-F 300/500V
According to CENELEC HD 22.10 S1
07 BQ-F AS3116 0.6/1Kv
Adapted to CENELEC HD
22.10 S1
Submersible EPR/PUR Flexible Cables
Test voltage
* Copper Conductor:
Flexible, tinned up to 16mmsq
Flexible, bare from 25mmsq upwards
[acc. to IEC 228 Class 5 resp. Class 6
for single -core cables]
* 300/500V : 2000 V,50 Hz, 5'
* 0.6/1Kv : 2500 V,50 Hz, 5'
Insulation:
re
ma
k
Construction
EPDM, compound type Ei6 ass. to
22.1 S2
* Filling sheath:
Halogen-free filling compound
[except single-core cables]
Outer Sheath;
HD
Halogen free polyurethane, compound
type TMPU acc. to HD
22.10 S1
* Screening if applicable will be tinned
copper braid. Pilot cores will be 1.5
mmsq Sheath colour * Orange [similar to
RAL 2003]
Core Colour
*2 core : brown, blue
*3 Core : brown, blue green/yellow
*4 Core : black, blue, brown, green/yellow
*5 Core : black,blue brown,blackgreen/yellow
From 7Core-: black with numbers,green-yellow
Temperature range
* -40 up to +90 degree Cel
Special characteristics
* Extreme mechanical resistance
[Abrasion-,tearing,-notch-,pressure
& wear resistant]
* Good reversed bending
strength
[min. 30000 reversed bendings
under current acc. to VDE 0472,
Part 603, Test H]
* Good chemical resistance
[against fuels, oils, grease, chemicals
& sewage]
* Resistant against enviromental
factors[as ozone, UV, humidity, water]
* Resistant against important
temperature fluctuations
* Flame retardant, halogen-free
* Submersible down to 500m
* Microbe & hydrolysis resistant
No
Quick Reference
Current Capacities Page A21
Gland Options Page F8, F9, F10
H05 BQ-F 300/500 V R-EP-90 Relvent Standard AS3191
Part
No
No of
Cores
x-section
mm sq
Max
Dia Wires
mm
Approx
Overall
Dia mm
Approx
Weight
Kg/Km
Maximum
Amps
Protected
from Sun
Nylon
Gland
Part No
Metal
Gland
IP66
Metal
Gland
IP68
77730275
77730210
77733g75
77733g10
77734g75
77734g10
77735g75
77735g10
2 x 0.75
2 x 1.0
3 x 0.75
3 x 1.0
4 x 0.75
4 x 1.0
5 x 0.75
5 x 1.0
0.21
0.21
0.21
0.21
0.21
0.21
0.21
0.21
7.0
7.5
7.5
8.0
8.0
8.5
9.0
9.5
65
78
78
91
91
108
113
137
12
18
12
18
12
18
12
18
NGM16
NGM16
NGM16
NGM16
NGM16
NGM16
NGM20
NGM20
MG20-16
MG20-16
MG20-16
MG20-S
MG20-S
MG20-S
MG20-S
MG20-S
MGS16
MGS16
MGS16
MGS16
MGS16
MGS16
MGS20
MGS20
A21
Flexible Power Cables
Submersible EPR/PUR
Flexible Cables
07 BQ-F AS3116 0.6/1Kv
Adapted to CENELEC HD
22.10 S1
re
ma
k
HO5 BQ-F 300/500V
According to CENELEC HD 22.10 S1
H07 BQ-F R-EP-90 Relevent Standard AS3191, AS3116 0.6/1Kv
No of
Cores
x-section
mm sq
Max
Dia
Strands
mm
Approx
Overall
Dia mm
77730215
77733G15
77733G25
77733G4
2 x 1.5
3 x 1.5
3 x 2.5
3x4
0.26
0.26
0.26
0.31
9.0
9.5
11.0
13.0
111
130
191
266
24
24
34
45
NGM16 MG20-S MGS20
NGM20 MG20-S MGS20
NGM20 MG20 MGS20
NGM25 MG20 MGS25
77734G15
77734G25
77734G4
77734G6
4 x 1.5
4 x 2.5
4x4
4x6
0.26
0.26
0.31
0.31
10.5
12.5
14.0
14.0
162
238
331
453
20
28
38
48
NGM20
NGM25
NGM25
NGM25
77735G15
77735G25
77735G4
77735G6
77735G10
77735G16
77735G025
77735G35
77735G50
5 x 1.5
5 x 2.5
5x4
5x6
5 x 10
5 x 16
5 x 25
5 x 35
5 x 50
0.26
0.26
0.31
0.31
0.41
0.41
0.41
0.41
0.41
11.5
13.5
16.0
18.0
23.1
26.5
33.5
38.0
43.5
195
291
411
559
951
1351
2169
2923
3945
20
28
38
48
66
88
120
145
180
NGM20 MG20 MGS20
NGM25 MG25 MGS25
NGM25 MG25 MGS32
NGM32 MG25 MGS32
NGM40 MG32 MGS40
NGM40 MG40 MGS40
NGM50 MG50-S MGS50
NGM63 MG50 MGS63
MG50
77737G15
77737G25
7 x 1.5
7 x 2.5
0.26
0.26
14.0
16.5
291
431
13
18
NGM25
NGM32
No
Part
No
Approx Maximum Nylon
Amps
Gland
Weight
Kg/Km Protected Part No
from Sun
Metal
Gland
IP66
MG20
MG20
MG25
MG25
MG25
MG25
Metal
Gland
IP68
MGS20
MGS20
MGS25
MGS25
MGS25
MGS32
A1
A22
Flexible Power Cables
Guide Only Refer to Australian Standards 3008.1.1 for complete listings and variations
Technical Information
For Flexible Cables
Ratings and Capacities are based on Flexible Cables used In Flexing Applications and NOT Flexible Cables used
for Fixed wiring applications. Refer to Australian Standards for these ratings AS 3008.1.1
re
ma
k
Operating Temperatures
0
Of Conductors C
Max
Normal Use
Permissible
AS3008.1.1 1998 Table1
Limiting Temperatures For Insulated Cables
Insulation Types
Insulation Types
Thermoplastic
V-75 and HFI-75-TP
V-90 and HFI-90-TP (AS 3008.1.1 For Conditions)
V90 HT (AS 3008.1.1 For Conditions)
75
75
75
75
90
105
Elastomer
R-EP-90, R-CPE-90, R-HF-90 and R-CSP-90
R-HF-110 and R-E-110
90
110
90
110
Cross Linked
Polyethylene (XLPE)
X-90 and X-HF-90
X-HF-110
90
110
90
110
AS3008.1.1 1998 Table16
Current Carrying Capacities Of Flexible Cords
Conductor Size mm
Number Of Layers
Derating Factor
0.50
0.75
1.00
3.0 (Conditions Apply)
7.5
10.0
1
0.76
2
0.58
15.0
20.0
25.0
3
0.47
4
0.40
2
1.50
2.50
4.00
0
Based On Ambient Air Temperature of 25 C
Current Carrying Capacities of 0.6/1 kV Flexible Cables
Protected From Sun
Exposed To Sun
Single And
2 Core
Single And
2 Core
Single And
2 Core
Single And
2 Core
V75, V90
R-EP-90
R-CSP-90
V75, V90
R-EP-90
R-CSP-90
6.0
10.0
16.0
44
60
81
54
74
99
34
46
60
43
58
77
25.0
35.0
50.0
110
135
160
135
165
195
80
95
110
105
125
145
70.0
95.0
120.0
205
240
280
250
290
340
140
160
185
185
210
245
150.0
185.0
240.0*
320
360
425
390
440
510
215
240
275
280
315
365
No
Conductor
2
Size mm
AS3008.1.1 1998 Table15
2
Derating For Cords Wound On a Drum 0.5-4.0mm
Current Carrying Capacity
Amps
Guide Only Refer to Australian Standards 3008.1.1 for complete listings and variations
A23
Flexible Power Cables
Guide Only Refer to Australian Standards 3008.1.1 for complete listings and variations
Technical Information
For Flexible Cables
Current Carrying Capacities of 0.6/1 kV Flexible Cables
Conductor
2
AS3008.1.1 1998 Table15
Size mm
6.0
10.0
16.0
25.0
35.0
50.0
70.0
95.0
120.0
150.0
185.0
240.0*
Exposed To Sun
re
ma
k
Protected From Sun
3 And
4 Core
3 And
4 Core
3 And
4 Core
3 And
4 Core
V75, V90
R-EP-90
R-CSP-90
V75, V90
R-EP-90
R-CSP-90
38
52
70
46
63
85
29
39
51
37
50
66
95
115
140
115
140
165
68
81
96
88
105
125
175
205
240
215
250
290
120
140
160
155
180
210
280
315
370
335
380
445
185
205
235
240
270
310
Current Carrying Capacities of R-S-150 Flexible Cords
Conductor
2
0.50
0.75
1.00
1.50
2.50
4.00
6.00
10.00
16.00
25.00
35.00
19
24
28
37
50
67
87
120
165
215
265
15
20
23
28
38
50
67
90
119
160
194
No
AS3008.1.1 1998 Table17
Size mm
Two Single Core Or One 2 Core
Three or Four Single Core
or 3 or 4 core
15
20
24
31
43
58
74
105
140
185
230
AC Derating Factors For Multi Core Cables
2
Greater Than 5 Core 1.5 To 10.0 mm
Number
Of Cores
Laying In air
Laying In Ground
5
7
10
14
19
24
40
61
0.75
0.65
0.55
0.50
0.45
0.40
0.35
0.30
0.70
0.60
0.50
0.45
0.40
0.35
0.30
0.25
13
16
19
24
32
42
55
76
99
135
163
A1
Flexible Power Cables
Guide Only Refer to Australian Standards 3008.1.1 for complete listings and variations
Technical Information
For Flexible Cables
re
ma
k
Three-Phase Voltage Drop At 50 Hz Of Multicore Flexible Cables And Cords
With Copper Conductors
Three Phase Voltage Drop At 50 Hz, mV/A.m
Conductor
2
Size mm
0.5
0.75
1.0
1.5
2.5
4.0
6.0
10.0
16.0
25.0
35.0
50.0
70.0
95.0
120.0
150.0
185.0
240.0
300.0
400.0
600.0
0
0
Conductor Temperature C
45
Conductor Temperature C
60
75
90
Max
0.8 p.f
Max
0.8 p.f
Max
0.8 p.f
Max
0.8 p.f
74.2
49.5
37.1
25.3
15.2
9.42
6.28
3.77
2.31
1.40
1.03
0.781
0.529
0.425
0.342
0.283
0.249
0.214
0.192
0.173
0.165
–
0.249
0.214
0.188
0.164
0.153
78.2
52.1
39.1
26.7
16.0
9.92
6.62
3.97
2.43
1.47
1.09
0.822
0.555
0.445
0.357
0.294
0.258
0.220
0.196
0.175
0.166
0.258
0.220
0.193
0.168
0.156
82.2
54.8
41.1
28.0
16.8
10.4
6.95
4.17
2.55
1.55
1.14
0.862
0.581
0.465
0.371
0.305
0.266
0.226
0.200
0.178
0.168
0.266
0.226
0.198
0.171
0.158
86.1
57.4
43.1
29.4
17.6
10.9
7.29
4.38
2.68
1.62
1.19
0.902
0.608
0.485
0.387
0.317
0.275
0.233
0.205
0.180
0.170
0.274
0.233
0.203
0.174
0.161
AC Resistance At 50 Hz Of Flexible Cables And Cords With Copper Conductors
Conductor
Size mm2
Multi Core Cables
0
0
Conductor Temperature C
45
60
75
90
45
60
75
90
42.8
28.6
21.4
14.6
8.76
5.44
3.62
2.17
1.33
0.803
0.589
0.442
0.293
0.229
0.178
0.140
0.116
0.0909
0.0729
0.0558
45.1
30.1
22.6
15.4
9.23
5.73
3.82
2.29
1.40
0.846
0.621
0.466
0.309
0.242
0.188
0.147
0.122
0.0955
0.0764
0.0583
47.4
31.6
23.7
16.2
9.70
6.02
4.01
2.41
1.47
0.889
0.652
0.489
0.324
0.254
0.197
0.155
0.128
0.100
0.0800
0.0609
49.7
33.2
24.9
17.0
10.2
6.31
4.21
2.52
1.54
0.932
0.684
0.513
0.340
0.266
0.206
0.162
0.134
0.105
0.0836
0.0634
42.8
28.6
21.4
14.6
8.76
5.44
3.62
2.17
1.33
0.803
0.589
0.442
0.293
0.230
0.179
0.141
0.117
0.0919
0.0741
0.0573
45.1
30.1
22.6
15.4
9.23
5.73
3.82
2.29
1.40
0.846
0.621
0.466
0.309
0.242
0.188
0.148
0.123
0.0965
0.0776
0.0598
47.4
31.6
23.7
16.2
9.70
6.02
4.01
2.41
1.47
0.889
0.652
0.490
0.325
0.254
0.198
0.155
0.129
0.101
0.0811
0.0623
49.7
33.2
24.9
17.0
10.2
6.31
4.21
2.52
1.54
0.932
0.684
0.513
0.340
0.266
0.207
0.163
0.135
0.106
0.0847
0.0648
No
0.5
0.75
1.0
1.5
2.5
4.0
6.0
10.0
16.0
25.0
35.0
50.0
70.0
95.0
120.0
150.0
185.0
240.0
300.0
400.0
Single Core Cables
Conductor Temperature C
For AC Resistance Of Tinned Copper Conductors Multiply Copper Value By 1.01
Guide Only Refer to Australian Standards 3008.1.1 for complete listings and variations
A24
A25
Flexible Power Cables
Guide Only Refer to Australian Standards 3008.1.1 for complete listings and variations
Technical Information
For Flexible Cables
re
ma
k
Current Carrying Capacities of
3 Single Core 0.6/1 kV Flexible Cables R-EP-90 Insulation
As Per AS/NZS 3008.1.1:1998 Table 7
Single Double Insulated Cables In
Fixed Application
Spaced
Spaced
from
Surface
Touching
1
1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185
240
300
400
19
25
35
46
59
81
110
145
180
220
280
350
410
470
550
660
770
900
16
21
30
40
50
69
92
125
155
190
240
300
350
405
470
560
650
760
16
20
28
37
47
65
86
115
145
175
225
280
325
375
435
520
600
700
No
Conductor
Size mm
Nonmetallic
wiring
enclosure
in air
14
18
25
33
42
58
78
110
125
155
190
230
270
310
355
420
485
560
Please refer to Australian Standards for full
conditions and notes which refer to this table
Guide Only Refer to Australian Standards 3008.1.1 for complete listings and variations
A1
Flexible Power Cables
Guide Only Refer to Australian Standards 3008.1.1 for complete listings and variations
Technical Information
re
ma
k
For Flexible Cables
Current Carrying Capacities of
3 Single Core 0.6/1 kV Flexible Cables R-E-110 Insulation
As Per AS/NZS 3008.1.1:1998 Table 8
Single Double Insulated Cables In
Fixed Application
Conductor
Size mm
Spaced
from
Surface
Touching
24
31
43
57
73
99
130
175
220
265
340
420
490
570
660
790
910
1070
21
27
38
50
63
86
115
155
190
230
290
365
420
485
560
670
780
910
20
25
36
47
59
81
105
145
175
215
270
340
395
455
530
630
730
850
No
1
1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185
240
300
400
Spaced
Nonmetallic
wiring
enclosure
in air
17
22
32
41
51
71
93
125
150
180
235
285
335
380
450
550
630
720
Please refer to Australian Standards for full
conditions and notes which refer to this table
A26
A27
Flexible Power Cables
Guide Only Refer to Australian Standards 3008.1.1 for complete listings and variations
Technical Information
For Flexible Cables
re
ma
k
Comparison of Current Ratings for Sheath Types As Per Australian Standards
Application: Touching Mounted to Tray etc
Conductor
Size mm
(1)
V75, V90
(2)
R-EP-90
(3)
R-E-110
13
16
20
16
20
25
23
28
36
31
37
47
40
47
59
54
65
81
72
86
105
97
115
145
120
145
175
145
175
215
185
225
270
230
280
340
265
325
395
150
310
375
455
185
355
435
530
240
425
520
630
300
490
600
730
400
570
700
850
1
1.5
2.5
4
6
10
16
25
35
50
70
95
No
120
Please refer to Australian Standards for full
conditions and information for the above ratings
A1
Flexible Power Cables
re
ma
k
This catalogue only covers the standard range of cables supplied
by Noremak Industries. Noremak can have cables manufactured
custom cables for the Australian electronics industry with many of these
products being used locally and exported on a world wide
Noremak is capable of having products and cables manufactured to
AS9002 and to Australian Standards including Austel, and can provide
cables to UL approval for those cables involved in export manufacturing.
Noremak Industries has a close relationship with many cable manufactures
in Australia and overseas and is able to have special purpose cables
manufactured to requirements and specialises in small run quantities.
These cables can be composed of any mixtures of conductors, pairs,
coaxial cables and a variety of strength members and other elements
depending on application
A few of examples which can be supplied
UNDER WATER VIDEO CAMERA CABLES
SEWER INSPECTION CABLES
MOBILE PHONE SYSTEM CABLES
DENTAL CABLES
No
METAL DETECTOR CABLES
Please contact Noremak Industries for your cable requirements for
Power and Data applications. Noremak can have cables produced to
your requirements in surprisingly short runs and in surprisingly quick
turn around times. We can also have leads and special application
plugs manufacturing capabilities.
Noremak Industries Pty Ltd
12 Princess Street
Beverley SA 5009
Phone 08 8244 7288 Fax 08 8244 7299
email: [email protected]
A28