Cables And Equipment Mining * Construction * Shipping * Manufacturing * Lighting & Entertainment Power Cables*Festoon Systems*Conductor Systems*Connectors*Cable Reelers High Voltage Couplers*Spring Reels*Grounding Reels*Fixed Power Cables Fibre Cables*Data Accessories*Glands*Manufactured Leads*Tools*Slip Rings Conveyor Monitoring Equipment*Auto Cables*Gaffa Reels*VSD Cables Aflex Cables Noremak Industries General Product Catalogue 2009-2010 Noremak Industries Pty Ltd 12 Princess Street Beverley SA 5009 PH: 08 8244 7288 Fax 08 8244 7299 email:[email protected] Section A Flex Power Cables re ma k Contents Single Double Insulated 110 EPR/CPE Flexible 0.6/1kV A1 Single Double Insulated R 90 Elastomer 0.6/1kV A2 Single Double Insulated 110 EPR/CPE 1.9/3.3kV Tinned A3 Single Double Insulated R90 EPR/CPE 0.6/1kV Screened A4 Single Insulated 90 C 0.6/1kV Flexible Earth Cables A5 Single Insulated R180 C 0.6/1kV Tinned Silicon A6 Single Insulated V90 HT PVC 0.6-1Kv Tinned Conductor A7 Multi Core R 90C NBR/NBR 0.6/1kV And 300/500v Multi Core R 90 C EPR/CPE 0.6/1kV And 300/500v Tinned Conductor A8, A9 A10, A11 A12 Multi Core Control V 90 C PVC/NBR 300/500v (White Numbered Cores) A13 Multi Core Control V 90 C PVC/PVC 300/500v (Black Numbered Cores) A14 Multi Core Control V 90 C PVC/PVC 300/500v Screened (Black Numbered Cores) A15 Multi Core R 90 C NBR/NBR 0.6/1kV Steel Braided A16 Twin V75 C NBR/TPE 0.6/1kV Flex Figure 8 A17 No Multi Core X 90 C XLPE/NBR And EPR/CPE Screened VSD Multi Core R 90 C EPR/PUR 0.6/1kV And 300/500v Technical Information A18, A19 A20 To A25 A1 Flexible Power Cables 0 110 C RATED 0 Single, Double Insulated 110 Deg Flexible Cable 0.6/1.0Kv LOW SMOKE HALOGEN FREE Temperature Range: re ma k Cable Construction *-30 to + 110 degrees C static -20 to +90 degrees C flexible * Conductors of extra fine wires to international standards to ensure maximum flexibility. * Insulation allows conductor temperature of 110 degrees C and is extremely flexible * Special jacket of outstanding toughness and flexibility, resistance to acid, solvents and oil at extreme temperatures * UV stabilised and flame retardant Rated Voltage: * 0.6/1Kv Relevant Standards: * VDE 0250, AS 3116, AS 1995, IEC 332-3 Maximum Conductor Temperature: * 110 Degrees C Bending Radius Fixed: * 5 times diameter of the cable Available Colors: HALOGEN FREE Part No 16 25 35 50 70 95 120 150 185 240 300 400 500 Stranding 470/0.20 726/0.20 1040/0.20 1499/0.20 2165/0.20 2745/0.20 1544/0.30 1961/0.30 2331/0.30 3172/0.30 3965/0.30 5246/0.30 6588/0.30 Overall Dia mm 9.30 10.80 12.10 13.70 15.50 17.90 19.80 22.10 24.40 27.10 29.90 33.50 37.20 No 777500163OR 777500253OR 777500353OR 777500503OR 777500703OR 777500953OR 777501203OR 777051503OR 777501853OR 777502403OR 777503003OR 777504003OR 777505003OR Size mm2 ***Orange*** Weight Kg/Km Nominal Current Single phase @ 40 Deg C * Hole Size Bootlace Pins Uninsulated Ferrules 130 175 220 265 340 420 490 570 660 790 910 1070 1250 CL16-*BM CL25-*BM CL35-*BM CL50-*BM CL70-*BM CL95-*BM CL120-*BM CL150-*BM CL185-*BM CL240-*BM CL300-*BM CL400-*BM - PBL16 PBL25 PBL35 PBL50 PBL70 PBL95 PBL120 - 202 293 390 535 725 870 1205 1500 1840 2350 2915 3817 4805 Bellmouth Lug Quick Reference Cable Technical Information Page 20-22 Current Carrying Capacities Fixed Applications Page 24 Lugs Page F1 Gland Options F8, F9 & F10 A1 A2 Flexible Power Cables 0 90 C RATED Single, Double Insulated Flexible Cable 0.6/1.0Kv Temperature Range: * Conductors of extra fine wires to international standards to ensure maximum flexibility. * Insulation allows conductor temperature of 90 degrees C and is extremely flexible NBR Elastomer * Special jacket of outstanding toughness and flexibility, resistance to acid, solvents and oil at extreme temperatures [see detailed properties chart of NBR Elastomer] * UV stabilised and flame retardant. *-30 to + 90 degrees C static -20 to +90 degrees C flexible Part No Cross Sectional Area mm Square Approx No: of Wires Stranding 6 10 16 25 35 50 70 95 120 150 185 240 300 400 172/0.21 304/0.21 462/0.21 742/0.21 1050/0.21 1482/0.21 2090/0.21 2812/0.21 1480/0.31 1887/0.31 2294/0.31 3034/0.31 3811/0.31 5246/0.31 Max Overall Dia mm No 777500061 777500101 777500161 777500251 777500351 777500501 777500701 777500951 777501201 777051501 777501851 777502401 777503001 777504001 re ma k Cable Construction 8.50 9.50 10.80 12.50 13.50 15.50 17.50 20.00 22.00 24.50 27.00 30.00 34.00 39.00 Rated Voltage: * 0.6/1Kv Relevant Standards: * VDE 0250, AS 3116, AS 1995, IEC 332-3 Maximum Conductor Temperature: * 90 Degrees C Bending Radius Fixed: * 5 times diameter of the cable Available Colors: ***Orange, Black, Red, & Blue *** ***Add to Part No When Ordering*** Weight Kg/Km 118 172 231 350 451 605 810 1075 1332 1654 2060 2576 3213 4200 Nominal Current Single phase @ 40 Deg C * Hole Size Bootlace Pins Uninsulated Ferrules 59 81 110 145 180 220 280 350 410 470 550 660 770 900 CL6-*BM CL10-*BM CL16-*BM CL25-*BM CL35-*BM CL50-*BM CL70-*BM CL95-*BM CL120-*BM CL150-*BM CL185-*BM CL240-*BM CL300-*BM CL400-*BM PBL06 PBL10 PBL16 PBL25 PBL35 PBL50 PBL70 PBL95 PBL120 - Quick Reference Cable Technical Information Page 20-22 Current Carrying Capacities Fixed Applications Page 23 Lugs Page F1 Gland Options F8, F9 & F10 Bellmouth Lug A3 Flexible Power Cables 0 110 C RATED re ma k Single, Double Insulated Flexible Cable EPR/CPE 1.9/3.3Kv Temperature Range: *-40 to + 110 degrees C static -20 to +90 * Tinned Stranded Conductors According to degrees C flexible Rated Voltage: VDE 0295 Class 5 * 1.9/3.3Kv Relevant Standards: * VDE 0250 * EPR Rubber Insulation Type 3G13 Part 602, AS 3116, AS3008, AS1125 Maximim * CPE Rubber Outer Sheath Conductor Temperature: * UV stablised and flame retardant. * 110 Degrees C * Resistant to oil and abrasion Bending Radius: * Submersible to 100 Mts * 4 times diameter of the cable Static 6 Times TYPICAL USES: Flexing Available Colours: Power Switchboards, flexible droppers from * Black bus bars, generators, load banks or Quick Reference anywhere SingleDouble insulated flexible cables are recommended Cable Technical Information Page 20-22 Battery leads, wiring looms, Automotive Current Carrying Capacities Fixed Applications Page 24 Lugs Page F1 battery chargers, electric fork lifts. Gland Options F8, F9 & F10 Leads, Earth & Power. Welding Cable Construction Part No 1.5 2.5 4.0 6.0 10.0 16.0 25.0 35.0 50.0 70.0 95.0 120.0 150.0 185.0 240.0 300.0 400.0 500.0 Approx No: of Wires Max Dia mm Max Overall Dia mm 30/0.25 50/0.25 56/0.30 84/0.30 80/0.40 126/0.40 196/0.40 276/0.40 396/0.40 540/0.40 715/0.40 920/0.40 1138/0.40 1390/0.40 1838/0.40 2275/0.40 3035/0.40 3795/.040 6.0 6.2 6.7 7.3 8.6 10.1 12.3 13.0 15.0 16.8 19.7 20.8 23.6 25.7 27.6 31.4 34.4 43.2 No 777633105 777633205 77763304 77763306 77763310 77763316 77763325 77763335 77763350 77763370 77763395 777633120 777633150 777633185 777633240 777633300 777633400 777633500 Cross Sectional Area mm Square Nominal Current Weight Spaced Kg/km @ 40 Deg C 31 43 57 73 99 130 175 220 265 340 420 490 570 660 790 910 1070 1250 65 80 95 120 180 250 350 455 610 805 1055 1350 1655 1975 2550 3230 4222 5200 Bell Mouth Lug Part No * Hole Size Bootlace Pins Uninsulated Ferrules CL6-*BM CL10-*BM CL16-*BM CL25-*BM CL35-*BM CL50-*BM CL70-*BM CL95-*BM CL120-*BM CL150-*BM CL185-*BM CL240-*BM CL300-*BM CL400BM PBL15 PBL025 PBL04 PBL06 PBL10 PBL16 PBL25 PBL35 PBL50 PBL70 PBL95 PBL120 - A1 A4 Flexible Power Cables re ma k Screened EPR/CPE Variable Speed Drive SDI Flexible Maximum Conductor Typical Uses The cable is designed primarily Temperature Cable Construction for large Variable Speed Drives and because of the dual screening gives maximum EMV protection +90C *Flexible tinned annealed copper Short Circuit 250C conductors, insulation EPR type IEP3 equivalent to 3G13 according to DIN VDE Temperature Range 0207 Part 20. -30C to +90C Flexing *Tinned Copper Braid screened min 80% -40C to +90C Fixed plus aluminium / mylar tape. Separator polyester tape. Outer Sheath CPE Bending Radius elastomer 10 x Cable Dia Fixed 12 x Cable Dia Flexing *UV stabilised and flame retardant Part No 120 150 185 240 Approx Max No: of Wires Overall Max Dia mm Dia mm 960/0.40 1200/0.40 1470/0.40 1870.0.40 No 777801120SC 777801150SC 777801185SC 777801240SC Cross Sectional Area mm Square 23.0 26.0 28.0 31.5 Nominal Current Spaced @ 40 Deg C Weight Kg/km 410 470 550 660 1460 1774 2170 2798 Bell Mouth Lugs EMC Approved Metal Gland * Hole Size CL120-*BM CL150-*BM CL185-*BM CL240-*BM Quick Reference Cable Technical Information Page 20-22 Current Carrying Capacities Fixed Applications Page 23 Lugs Page F1 Gland Options F8, F9 & F10 CABLE PROBLEMS? NOREMAK INDUSTRIES FOR: CABLE SOLUTIONS PHONE:(08)8244 7288 FAX:(08)8244 7299 [email protected] MG40EMCL MG40EMCL MG50EMCL MG50EMCL A5 Flexible Power Cables re ma k Single Insulated Flexible Earth Cable TPE 0.6/1kV Cable Construction Temperature Range * Conductors of extra fine wires to international standards to ensure maximum flexibility. Static - 30 to + 90 degree C Flexible -20 to + 90 degree C * Insulation allows conductor temperatures of 90 degree C & is extremely flexible special TPE compound. Typical Uses * UV stabilised & flame retardant Part No Cross Sectional area mm square Approx No of Wires Max Dia mm Nominal overall Dia mm Weight Kg/Km 6 10 16 25 35 50 70 95 120 150 300 84/0.30 128/0.30 196/0.30 308/0.30 434/0.30 608/0.30 874/0.30 1178/0.30 1480/0.30 1887/0.30 3811/0.30 4.8 6.4 7.7 9.5 10.6 12.5 14.8 17.0 18.5 21.0 29.7 109 155 220 325 430 590 800 1040 1300 1500 2950 No 77710006 77710010 77710016 77710025 77710035 77710050 77710070 77710095 77710120 77710150 77710300 Power: Switchboards, Flexible droppers from busbars flexible links, transformers, generators, load banks, or anywhere green/yellow flexible earth cables are to be used. Welding earth leads. Lugs * Hole Size Quick Reference Lugs Page F1 Gland Options F8, F9 & F10 CL6-*BM CL10-*BM CL16-*BM CL25-*BM CL35-*BM CL50-*BM CL70-*BM CL95-*BM CL120-*BM CL150-*BM CL300-*BM Bootlace Pins Uninsulated Ferrules PBL06 PBL10 PBL16 PBL25 PBL35 PBL50 PBL70 PBL95 PBL120 - A7 Flexible Power Cables Noremak Cable Construction re ma k Single Insulated V90 HT PVC Flexible Cables 0.6-1Kv Rated Tinned Copper Cores Max0 Conductor Temperature Typical Uses Available Colours Internal Wiring of Electronic equipment, Switchboards Control panels +90 C * Tinned copper conductors * Insulation V90 HT PVC * Manufactured in accordance with AS3191 Or AS3178 Part No 0.50 0.75 1.00 1.50 2.50 4.00 6.00 Approx Nominal Insulation overall No of Wires Thickness Dia mm Max Dia mm 2.60 2.80 3.00 3.20 3.90 5.40 5.50 No 4271C16020** 4271C24020** 4271C32020** 4271C30025** 4271C50025** 4271C56030** 4271C84030** Cross Sectional area mm square Red, Blue, Black, Yellow, White Brown, Violet, Orange Pink, Grey, Green Green/Yellow Other Cables Available On Request 16/0.20 24/0.20 32/0.20 30/0.25 50/0.25 56/0.30 84/0.30 0.80 0.80 0.80 0.80 0.90 1.00 1.00 Quick Reference Current Capacities Page A21 Lug Options F4 Insulated Un-Insulated Ring Ring Terminal Terminal * Hole Size * Hole Size TRRD-*DG TRRD-*DG TRBU-*DG TRBU-*DG TRY-*DG TRY-*DG TRY-*DG TRU05-*DG TRU07-*DG TRU10-*DG TRU15-*DG TRU25-*DG TRU04-*DG TRU06-*DG A1 Flexible Power Cables 0 re ma k Single Insulated 180 Silicon Flexible Cables Cable Construction Maximum Conductor Temperature * Tinned copper conductors, all Class 5 Stranding. +180C Short Term 220C * Silicon Insulation tear and heat resistant Compound Temperature Range * Typical Uses Static - 60 to + 180 degree C Flexible -40 to + 180 degree C Short Term 220C UV stabilised & Flame Retardant Electric signs and connections Motor Appliances Heavy Industry Medical Areas Ship and Railway Building Foundry Switch Boards Bending Radius 4 x Cable Dia Fixed Colours Available 2 2 0.75mm To 1.5mm: Earth, Black, Brown, Yellow, Grey, Blue, Orange, Red, Violet, White 2 2.5mm: Earth, Black, Blue, Red, White 2 2 4.0mm To 25.0mm: Red, Black Part No Nominal overall Dia mm Weight Kg/Km Un-Insulated Lugs * Hole Size Insulated Ring Terminals * Hole Size 0.75 1.0 1.5 2.5 4.0 6.0 10.0 16.0 25.0 2.4 2.5 2.8 3.4 4.2 5.2 6.4 8.0 10.0 13.3 15.9 21.9 34.7 54.4 82.3 131.9 209.1 326.7 CL1.5-* CL1.5-* CL2.5-* CL4.0-* CL6.0-* CL10-* CL16-* CL25-* TRRD-*DG TRRD-*DG TRBU-*DG TRBU-*DG TRY-*DG TRY-*DG - No 777S01075 777S01010 777S01015 777S01025 777S01040 777S01060 777S01010 777S01016 777S01250 Cross Sectional area mm square Quick Reference Lugs Page F1 & F4 Gland Options F8, F9 & F10 A6 A1 Flexible Power Cables Noremak re ma k PVC Flexible Multi Core Cables Ordinary And Heavy Duty V90-HT OD Multi Core Flex 250V/440V Part No No: of Cores & mm square Stranding Nominal overall Dia mm Insulation Thickness PVC2C75OD** PVC3C75OD** PVC4C75OD** PVC5C75OD** 2 x 0.75 3 x 0.75 4 x 0.75 5 x 0.75 24/0.20 24/0.20 24/0.20 24/0.20 6.40 6.80 7.30 8.20 0.6 0.6 0.6 0.6 2 x 1.0 3 x 1.0 4 x 1.0 5 x 1.0 32/0.20 32/0.20 32/0.20 32/0.20 6.70 7.00 7.80 8.60 0.6 0.6 0.6 0.6 Black, Red, Orange, White Grey Blue 2 x 1.5 3 x 1.5 4 x 1.5 5 x 1.5 30/0.25 30/0.25 30/0.25 30/0.25 7.70 8.10 9.10 10.20 0.7 0.7 0.7 0.7 Voltage Rating 250/440V 3 x 2.5 4 x 2.5 5 x 1.5 50/0.25 50/0.25 50/0.25 10.00 11.00 12.40 0.8 0.8 0.8 3 x 4.0 4 x 4.0 5 x 4.0 56/0.30 56/0.30 56/0.30 11.40 12.50 13.80 0.8 0.8 0.8 Available Colours PVC2C01OD** PVC3C01OD** PVC4C01OD** PVC5C01OD** PVC2C15OD** PVC3C15OD** PVC4C15OD** PVC5C15OD** PVC3C25OD** PVC4C25OD** PVC5C25OD** PVC3C04OD** PVC4C04OD** PVC5C04OD** Standards AS3191 HD Multi Core Flex 0.6/1Kv No: of Cores & mm square Stranding Nominal overall Dia mm Insulation Thickness PVC2C75HD** PVC3C75HD** PVC4C75HD** PVC5C75HD** 2 x 0.75 3 x 0.75 4 x 0.75 5 x 0.75 24/0.20 24/0.20 24/0.20 24/0.20 8.20 8.80 9.70 10.70 1.30 1.40 1.50 1.60 PVC2C01HD** PVC3C01HD** PVC4C01HD** PVC5C01HD** 2 x 1.0 3 x 1.0 4 x 1.0 5 x 1.0 32/0.20 32/0.20 32/0.20 32/0.20 8.50 9.00 10.00 11.00 1.30 1.40 1.50 1.60 PVC3C15HD** PVC4C15HD** PVC5C15HD** 3 x 1.5 4 x 1.5 5 x 1.5 30/0.25 30/0.25 30/0.25 10.00 11.00 12.20 1.60 1.70 1.80 PVC3C25HD** PVC4C25HD** PVC5C25HD** 3 x 2.5 4 x 2.5 5 x 1.5 50/0.25 50/0.25 50/0.25 12.00 13.00 14.40 1.80 1.90 2.00 PVC3C04HD** PVC4C04HD** PVC5C04HD** 3 x 4.0 4 x 4.0 5 x 4.0 56/0.30 56/0.30 56/0.30 13.90 15.30 17.00 1.90 2.00 2.20 No Part No Available Colours **Add To Part No Black, Red, Orange, White Grey Blue Voltage Rating 0.6/1Kv Standards AS3191 A8 A9 Flexible Power Cables Silicon Multi Core Flexible Cables re ma k Low Smoke Halogen Free Cable Construction * * * Tinned copper conductors, all Class 5 stranding. Silicon Insulation tear and heat resistant compound Working Temperature 0 Typical Uses 0 -60 C To +180 C Electric Motor Applications Power Supplies Medical Areas Railway And Shipping Rated Voltage 450/750V Low Smoke Halogen Free OD Multi Core Flex 250V/440V Part No Stranding Nominal overall Dia mm Cable Weight Kg/Km 3 X 0.75 4 X 0.75 2 X 1.0 3 X 1.0 4 X 1.0 5 X 1.0 3 X 1.5 4 X 1.5 5 X 1.5 7 X 1.5 12 X 1.5 19 X 1.5 3 X 2.5 4 X 2.5 5 X 2.5 4 X 4.0 4 X 6.0 24/0.20 24/0.20 32/0.20 32/0.20 32/0.20 32/0.20 30/0.25 30/0.25 30/0.25 30/0.25 30/0.25 30/0.25 50/0.25 50/0.25 50/0.25 56/0.30 84/0.30 6.80 7.80 6.60 7.40 8.10 8.80 8.00 8.80 9.60 10.40 14.60 17.00 9.70 10.60 11.60 13.20 15.60 76.0 101.0 76.0 93.0 113.0 133.0 117.0 145.0 175.0 220.0 413.0 591.0 179.0 222.0 268.0 346.0 497.0 No 777S0375 777S0475 777S0201 777S0301 777S0401 777S0501 777S0315 777S0415 777S0515 777S0715 777S1215 777S1915 777S0325 777S0425 777S0525 777S0404 777S0406 No: of Cores & mm square A1 A10 Flexible Power Cables Cable Construction re ma k NBR Rubber Elastomer Insulated and Sheathed High Flex Power and Control Cables Heavy Duty 0.6/1kV Ordinary Duty 250/440V Temperature Range *Conductors: annealed fine wires of plain electrolytic copper stranded for high flexibility. *Insulation of special flame retardant NBR Elastomer compound formulated for high flexibility & durable operation in extreme temperatures. *Separator or bedding of extruded or taped NBR material. Silicated powder lubricant between cores & inner sheath to reduce friction. *NBR Elastomer for outstanding flexibility & durability in most hostile environments. *UV Stabilised & fire retardant. -30 to +90 degree C static -20 to +90 degree C flexible Bending Radius 5 times diameter - fixed 6 times diameter - flexible Rated Voltage O.D.250/440V HD 0.6/1kV Maximum Conductor Temperature 90 degree C Relevant Standards Quick Reference AS3147, AS3191, IEC227, IEC332.1 AS3008.1.1 1998 Table 13 Fixed, Table 15 Flexing Pages 31, 34 Applications Current Capacities Page A21 Gland Options F8, F9 & F10 In machine tools, construction & engineering equipment, conveyors & other industrial application where outstanding flexibility is required under tough climatic & mechanical conditions. Diesel powered generator sets, load banks, ship to shore cables. No OD Multi Core Flex Orange 250V/440V Part No 77700201OR 77700301OR 77700315OR 77700325OR 77700401OR 77700415OR 77700425OR 77700525OR No: of Stranding Cores & mm square 2 x 1.0 3 x 1.0 3 x 1.5 3 x 2.5 4 x 1.0 4 x 1.5 4 x 2.5 5 x 2.5 32/0.21 32/0.21 48/0.21 80/0.21 32/0.21 48/0.21 80/0.21 80/0.21 Nominal Weight overall Kg/Km Dia mm 6.8 7.4 8.4 10.0 8.0 9.2 11.2 12.5 70 80 105 160 100 130 200 240 Nominal Nylon Gland Metal Gland Amps Part No Part No Protected IP66 from Sun 10 10 15 20 10 15 20 20 NGM16 NGM16 NGM16 NGM20 NGM16 NGM20 NGM20 NGM25 MG20-S MG20-S MG20-S MG20-S MG20-S MG20-S MG20 MG20 IP68 Glands Also Available A11 Flexible Power Cables NBR Rubber Elastomer Insulated and Sheathed High Flex Power and Control Cables Heavy Duty 0.6/1kV Ordinary Duty 250/440V Heavy Duty Multi Core Flex 0.6/1kV No: of Stranding Cores & mm square Nominal Overall Dia mm Weight Kg/Km Nominal Amps Protected fromSun Nylon Gland Metal Gland Part No Part No IP66 32/0.21 32/0.21 32/0.21 9.8 10.5 11.6 90 100 130 10 10 10 NGM20 NGM20 NGM20 MG20-S MG20-S MG20 48/0.21 48/0.21 48/0.21 48/0.21 48/0.21 10.5 11.6 13.0 15.0 16.7 140 170 210 268 425 15 15 15 15 15 NGM20 NGM20 NGM25 NGM32 NGM32 MG20-S MG20 MG20 MG25 MG25 80/0.21 80/0.21 80/0.81 80/0.21 80/0.21 80/0.21 12.4 14.0 15.4 15.8 19.2 25.4 194 239 289 365 589 785 20 20 20 20 20 20 NGM25 NGM25 NGM25 NGM25 NGM32 NGM40 MG20-S MG25 MG25 MG25 MG25 MG32 127/0.21 127/0.21 127/0.21 127/0.21 127/0.21 13.7 14.4 16.0 17.4 20.0 275 319 394 482 600 25 25 25 25 25 NGM25 NGM25 NGM25 NGM32 NGM32 MG25 MG25 MG25 MG25 MG2 190/0.21 190/0.21 190/0.21 15.9 19.0 21.0 406 505 619 46 46 46 NGM25 NGM32 NGM32 MG25 MG32 MG32 re ma k Part No 3 x 1.0 4 x 1.0 5 x 1.0 77700315 77700415 77700515 77700715 77701215 3 x 1.5 4 x 1.5 5 x 1.5 7 x 1.5 12 x 1.5 77700325 77700425 77700525 77700725 77701225 77701825 3 x 2.5 4 x 2.5 5 x 2.5 7 x 2.5 12 x 2.5 18 x 2.5 77700204 77700304 77700404 77700504 77700704 2x4 3x4 4x4 5x4 7x4 77700306 77700406 77700506 3x6 4x6 5x6 77700310 77700410 77700510 3 x 10 4 x 10 5 x 10 318/0.21 318/0.21 318/0.21 23.7 25.8 28.1 803 975 1190 63 63 63 NGM40 NGM40 NGM50 MG32 MG32 MG40 77700316 77700416 77700516 3 x 16 4 x 16 5 x 16 504/0.21 504/0.21 504/0.21 26.0 28.6 31.7 1040 1285 1590 85 85 85 NGM40 NGM50 NGM50 MG40 MG40 MG40 No 77700301 77700401 77700501 Black Standard Orange Available On Request Cable Technical Information Page A20, A21 & A22 Gland Options F8, F9 & F10 Voltage Drop Figures Page A22 IP68 Glands Also Available A1 A12 Flexible Power Cables Cable Construction re ma k Flexible Submersible Harmonised Rubber Sheathed Cables VDE Approved Properties [cont] *Copper conductors [tinned up to 16 sq mm],acc.to VDE 0295, CLASS 5; *PETP-tape [only for sections above 16 sq,mm] *EPR rubber insulation type E14 acc. to HD22; *Elastomeric outer sheath type EM2 acc to HD222 * Oil resistant * Resistant to environmental factors like oxidation, ozone, sunlight * Flame retardant * Very good behavior to variations of outdoor temperature Voltage Rating Operating Temperature *Minimum permissible ambient temperature - 40 degrees Cel *Maximum permissible short circuit temperature 250 degrees Cel *Minimum ambient temperature for optimum fully flexible operations - 25 degrees C * Rated Voltage UO/U = 0.6/1kv * Maximum operating voltages in: 3 phase AC Operation UO/U = 0.7/1.15kV DC operation UO/U=0.9/1.73kV * The cable is designated 450/750V with E14 insulation compound in accordance with VDE/IEC and meets or exceeds the Australian Standards AS3116 for the voltage rating of 0.6/1kV, R-EP-90 Minimum Bending Radii Applications The following minimum bending radius should be observed to ensure operating reliability. * For fixed installation - 4 x cable Diameter * When freely flexing - 5 x cable Diameter * For drag chains & reels - 10x cable Diameter * For medium level mechanical loads, for use in dry & damp locations, for outdoor use or in locations subject to explosion hazards, * For industrial & workshop equipment * For connections of mobile machines & engines on construction sites, * As fixed installation, for example as installation on plaster in temporary buildings Properties Colour Code * Good tensile strength, tearing strength & abrasion resistance * Good elongation at breaks * Good dialectical properties * Acid resistant * 2 conductors : Brown-Blue * 3 conductors : Brown-Blue-Green/Yellow * 4 conductors : Grey-Black-Brown-Green/Yellow * 5 conductors : Grey-Black-Brown-Blue-Green/Yellow *Submersible to 100 Mtr No HO5RN-F 300/500v Part No 77711275H05 77711201H05 777113G75H05 777113G1H05 777114G75H05 No Cores Stranding Nominal & Overall MM Square Dia mm 2 x 0.75 2 x 1.0 3 x 0.75 3 x 1.0 4 x 0.75 0.21 0.21 0.21 0.21 0.21 6.4 7.1 7.0 8.5 8.8 Weight Kg/Km 78 94 94 114 90 Maximum Nylon Amps Gland Protected Part No from Sun 12 18 12 18 12 Quick Reference Current Capacities Page A21 Gland Options Page F8, F9 And F10 Metal Gland IP66 Metal Gland IP68 NGM16 MG20-16 MGS16 NGM16 MG20-16 MGS16 NGM16 MG20-16 MGS16 NGM16 MG20-S MGS16 NGM16 MG20-S MGS16 A13 Flexible Power Cables Flexible Submersible Harmonised Rubber Sheathed Cables VDE Approved HO7RN-F 0.6-1Kv No of cores Max Dia & size of Strands mm sq mm Overall Dia Weight Kg/Km Max allowable current under permanent conditions 40deg Cel Amps Nylon Gland Part No Metal Gland IP66 Metal Gland IP68 re ma k Part No 0.21 0.26 0.26 0.31 0.31 0.41 0.41 9.4 9.4 11.5 13.0 14.5 19.5 22.0 100 130 190 260 350 620 850 18 24 34 45 57 78 105 NGM16 NGM16 NGM20 NGM25 NGM25 NGM32 NGM32 MG20-S MG20-S MG20 MG25 MG25 MG32 MG32 MGS20 MGS20 MGS20 MGS25 MGS25 MGS32 MGS40 0.21 0.26 0.26 0.31 0.31 0.41 0.41 0.41 9.10 10.10 12.0 14.0 15.5 21.0 24.0 29.0 125 160 230 320 425 765 1060 1560 18 24 34 45 57 78 105 140 NGM20 NGM20 NGM20 NGM25 NGM25 NGM32 NGM40 NGM50 MG20-S MG20-S MG20 MG25 MG25 MG32 MG32 MG40 MGS20 MGS20 MGS20 MGS25 MGS25 MGS40 MGS40 MGS50 4 x 1.0 4 x 1.5 4 x 2.5 4 x 4.0 4 x 6.0 4 x 10.0 4 x 16.0 4 x 25.0 4 x 35.0 4 x 50.0 4 x 70.0 4 x 95.0 4 x 120.0 0.21 0.26 0.26 0.31 0.31 0.41 0.41 0.41 0.41 0.41 0.51 0.51 0.51 10.0 11.50 13.50 15.50 17.50 23.0 26.0 32.0 35.0 40.0 45.0 51.0 56.0 155 200 290 400 540 930 1300 1950 2330 3200 4200 5490 7098 16 20 28 38 48 66 88 120 145 180 230 285 330 NGM20 NGM20 NGM25 NGM25 NGM32 NGM40 NGM40 NGM50 NGM63 NGM63 - MG20-S MG20 MG25 MG25 MG25 MG32 MG40 MG50-S MG50-S MG50 MG63-S MG63 MG63 MGS20 MGS20 MGS25 MGS25 MGS32 MGS40 MGS40 MGS50 MGS63 MGS63 777115g1 777115G15 777115G025 777115G4 777115G6 777115G10 777115G16 777115G25 777115G35 777115G50 777115G70 777115G95 5 x 1.0 5 x 1.5 5 x 2.5 5 x 4.0 5 x 6.0 5 x 10.0 5 x 16.0 5 x 25.0 5 x 35.0 5 x 50.0 5 x 70.0 5 x 95.0 0.21 0.26 0.26 0.31 0.31 0.41 0.41 0.41 0.41 0.41 0.51 0.51 11.5 12.5 15.0 17.0 19.0 25.0 29.0 35.0 39.0 45.0 50.0 56.6 190 240 350 500 670 1140 1610 2440 2900 4000 5250 6780 16 20 28 38 48 66 88 120 145 180 230 285 NGM20 NGM25 NGM25 NGM32 NGM32 NGM40 NGM50 NGM63 NGM63 - MG20 MG20 MG25 MG25 MG25 MG32 MG40 MG50-S MG50 MG63S MG63 - MGS20 MGS20 MGS25 MGS32 MGS32 MGS40 MGS50 MGS63 MGS63 - 777117G15 777117G25 777117G4 777117G6 777117G10 7 x 1.5 7 x 2.5 7 x 4.0 7 x 6.0 7 x 10 0.26 0.26 0.31 0.31 0.41 16.0 18.50 21.50 24.80 29.50 330 470 660 956 1494 13 18 22 31 41 NGM25 NGM32 NGM32 NGM40 NGM50 MG25 MG25 MG32 MG32 MG40 MGS32 MGS32 MGS40 MGS40 MGS50 777112G15 777112G25 12 x 1.5 12 x 2.5 0.26 0.26 19.0 22.50 480 690 13 18 NGM32 NGM40 MG32 MG32 MGS32 MGS40 777118G15 777118G25 18 x 1.5 18 x 2.5 0.26 0.26 22.0 26.50 690 1010 13 18 NGM32 NGM40 MG32 MG40 MGS40 MGS40 7771127G15 7771127G25 7771137G15 27 x 1.5 27 x 2.5 37 x 1.5 0.26 0.26 0.26 28.10 33.50 30.10 1102 1521 1310 13 18 13 NGM50 NGM50 NGM50 MG40 MG50-S MG40 MGS50 MGS50 MGS50 2 x 1.0 2 x 1.5 2 x 2.5 2 x 4.0 2 x 6.0 2 x 10.0 2 x 16.0 777113G1 777113G15 777113G25 777113G4 777113G6 777113G10 777113G16 777113G025 3 x 1.0 3 x 1.5 3 x 2.5 3 x 4.0 3 x 6.0 3 x 10.0 3 x 16.0 3 x 25.0 777114G1 777114G15 777114G25 777114G4 777114G6 777114G10 777114G16 777114G025 777114G35 777114G50 777114G70 777114G95 77114G120 No 77711201 77711215 77711225 77711240 77711260 77711210 77711216 - A1 Flexible Power Cables XLPE/NBR 90C 0.6/1Kv Screened Flexible Variable Speed Drive Cable * Rated Voltage re ma k Cable Construction 0.6/1Kv Conductors of extra fine bare annealed copper wires. Insulation Relevant Standards AS3147, IEC332-1 Maximum Conductor Temperature XLPE 90 Deg C -30 to +90 degree C Screening Colour Aluminium/Maylar tape plus tinned copper braid up to 4.0mm, above is tinned copper braid Sheath Black / Clear To 35.0mm Black Only Over 35.0mm Bending Radius Clear Sheath is TPE 1.5mm to 35.0mm Back Sheath NBR to 6.0mm and CPE 10.0mm and above Fixed >20.0mm 7.5x diam<20.0mm 10x Cable diam Flexing>20.0mm 15xcable diam <20.0mm x 20 cable diam UV Stabilised and Flame Retardant AS 3008.1.1 1998 Table 13 Fixed Table 15 Flexing Cross Sectional area mm square 77780315SC 77780325SC 77780415SC 77780425SC 77780404SC 77780406SC 77780410SC 77780416SC 777804025SC 77780435SC 77780450SC 77780470SC 77780495SC 777804120SC 777804150SC 77780525SC 77780506SC 1.5 2.5 1.5 2.5 4.0 6.0 10.0 16.0 25.0 35.0 50.0 70.0 95.0 120.0 150.0 2.5 6.0 Power Cores Earth Cores Nominal overall Dia mm Weight Kg/Km Amps Spaced EMC Compliant Metal Gland 2x1.5 2x2.5 3x1.5 3x2.5 3x4.0 3x6.0 3x10.0 3x16.0 3x25.0 3x35.0 3x50.0 3x70.0 3x95.0 3x120.0 3x150.0 4x2.5 4x6.0 1x1.5 1x2.5 1x1.5 1x2.5 1x4.0 3x1.5 3x1.5 3x2.5 3x4.0 3x6.0 3x10.0 3x10.0 3x16.0 3x16.0 3x25.0 1x2.5 1x6.0 12.5 13.5 13.5 14.5 16.5 19.5 21.5 23.5 28.5 32.0 40.0 43.3 48.7 51.3 58.5 18.7 21.0 155 195 195 245 350 445 675 955 1455 2200 3211 3950 5126 5925 7146 533 952 24 34 20 28 38 48 66 88 120 145 180 230 285 330 375 28 48 MG20EMCL MG25EMCL MG25EMCL MG25EMCL MG25EMCL MG32EMCL MG40EMCL MG40EMCL MG50EMCL MG50EMCL MG63EMCL No Part No Please Refer to Noremak For More Information On Larger Sizes And Options MG32EMCL MG40EMCL Please refer to Australian Standards for full conditions and notes which refer to this table Quick Reference Current Capacities Page A21 Gland Options Page F9 A14 A15 Flexible Power Cables Flexible Control PVC/NBR 0.3/0.5kV Cable Construction PVC Insulated re ma k *Conductors annealed fine wires of plain electrolytic copper stranded for high flexibility. Part No Cores: white insulated with sequential black numbers, 1green/yellow Protective sheath of flame retardant NBR Elastomer for outstanding flexibility & durability in most hostile environments. UV stabilised & flame retardant Screening if applicable will be tinned copper braid. 85% minimum coverage. Suitable for protection against EMI Radiation Temperature Range Static - 30 to + 80 degree C Flexing -5 to + 70 degree C Rated Voltage 300/500 votls Relevant Standards VDE 0295 class 5 [ conductor] VDE 0812 [cores] IEC 332-1 Maximum Conductor Temperature 90 degree C No Bending Radius For flexing application: 15 times diameter unscreened 20 times diameter screened Applications As power control or signal cables on machines, portable tools, conveying equipment & similar industrial applications. No of Cores Approx O.D. Section mm mm square Approx Weight Kg/Km Nylon Gland Metal Gland IP66 77720205 77720305 77720405 77720505 77720705 77721205 77721805 77722505 77723005 77724105 2 x 0.5 3 x 0.5 4 x 0.5 5 x 0.5 7 x 0.5 12 x 0.5 18 x 0.5 25 x 0.5 30 x 0.5 41 x 0.5 4.8 5.1 5.7 6.6 7.0 9.4 11.1 12.4 13.3 16.6 35 42 54 67 84 131 192 261 304 450 NGM12 NGM12 NGM16 NGM16 NGM16 NGM20 NGM20 NGM25 NGM25 NGM25 MG20-16 MG20-16 MG20-16 MG20-16 MG20-S MG20-S MG20 MG20 MG25 MG25 77720375 77720475 77720575 77720775 77721275 77721875 77722575 3 x 0.75 4 x 0.75 5 x 0.75 7 x 0.75 12 x 0.75 18 x 0.75 25 x 0.75 6.0 6.2 7.1 7.6 10.6 12.2 14.3 66 88 100 161 247 268 465 NGM16 NGM16 NGM16 NGM16 NGM20 NGM25 NGM25 MG20-16 MG20-16 MG20-16 MG20-16 MG20-S MG20 MG25 77720301 77720401 77720501 77720701 77721201 77721801 77722501 77723601 77724101 3 x 1.0 4 x 1.0 5 x 1.0 7 x 1.0 12 x 1.0 18 x 1.0 25 x 1.0 36 x 1.0 41 x 1.0 6.0 6.5 7.6 8.0 11.1 13.4 15.4 18.2 18.8 65 79 105 131 220 315 449 620 660 NGM16 NGM16 NGM16 NGM16 NGM20 NGM25 NGM25 NGM32 NGM32 MG20-16 MG20-16 MG20-16 MG20-S MG20 MG25 MG25 MG25 MG25 77720215 77720315 77720415 77720515 77720715 77721215 77721815 77721915 77722515 77723015 77723715 77725015 2 x 1.5 3 x 1.5 4 x 1.5 5 x 1.5 7 x 1.5 12 x 1.5 18 x 1.5 19 x 1.5 25 x 1.5 30 x 1.5 37 x 1.5 50 x 1.5 8.5 6.7 8.3 9.1 9.7 13.4 16.2 16.5 19.5 20.5 22.0 26.0 84 117 121 144 237 393 465 542 655 750 980 1224 NGM16 NGM16 NGM16 NGM20 NGM20 NGM25 NGM25 NGM32 NGM32 NGM32 NGM40 NGM40 MG20-S MG20-S MG20-S MG20-S MG20-S MG25 MG25 MG25 MG32 MG32 MG32 MG40 77720425 77720725 77721225 77721825 77722725 4 x 2.5 7 x 2.5 12 x 2.5 18 x 2.5 27 x 2.5 11.0 13.0 17.5 21.0 25.0 192 310 524 784 900 NGM20 NGM25 NGM32 NGM32 NGM40 MG20 MG25 MG25 MG32 MG40 Quick Reference Current Capacities Page A20 Multi Core Deratings A21 Gland Options Page F8, F9 And F10 A1 A16 Flexible Power Cables Flexible Control PVC/PVC 0.3/0.5Kv Cable Construction wires of plain electrolytic copper stranded for high flexibility. *PVC Insulated No of Cores Approx Approx Section O.D. Weight mm square mm Kg/Km Nylon Gland Metal Gland IP66 re ma k Part No *Conductors annealed fine *Cores: Black insulated with sequential white numbers, Plus 1 green/yellow *Protective sheath of flame retardant PVC for outstanding flexibility & durability in most hostile environments. *UV stabilised & flame retardant Temperature Range *Static - 30 to + 80 degree C *Flexing -5 to + 70 degree C Relevant Standards VDE 0295 class 5 [ conductor] VDE 0812 [cores] IEC 332-1 3 x 0.50 4 x 0.50 5 x 0.50 7 x 0.50 12 x 0.50 18 x 0.50 25 x 0.50 5.1 5.7 6.2 6.7 8.9 10.5 12.5 42 54 63 81 131 188 261 NGM12 NGM16 NGM16 NGM16 NGM16 NGM20 NGM20 MG20-16 MG20-16 MG20-16 MG20-16 MG20-S MG20-S MG20 77720375P 77720475P 77720575P 77720775P 77721275P 77721875P 77722575P 3 x 0.75 4 x 0.75 5 x 0.75 7 x 0.75 12 x 0.75 18 x 0.75 25 x 0.75 5.7 6.2 6.7 7.3 10 11.8 13.8 55 66 79 101 171 244 337 NGM12 NGM16 NGM16 NGM16 NGM20 NGM20 NGM25 MG20-16 MG20-16 MG20-16 MG20-16 MG20-S MG20 MG25 77720301P 77720401P 77720501P 77720701P 77721201P 77721801P 77722501P 3 x 1.0 4 x 1.0 5 x 1.0 7 x 1.0 12 x 1.0 18 x 1.0 25 x 1.0 6.0 6.5 7.1 8.0 10.5 12.7 14.7 65 79 94 126 205 300 408 NGM16 NGM16 NGM16 NGM16 NGM20 NGM25 NGM25 MG20-16 MG20-16 MG20-16 MG20-S MG20-S MG20 MG25 77720315P 77720415P 77720515P 77720715P 77721215P 77721815P 77722515P 3 x 1.5 4 x 1.5 5 x 1.5 7 x 1.5 12 x 1.5 18 x 1.5 25 x 1.5 6.7 7.2 8.1 9.0 12 14.4 17.0 84 104 128 166 279 407 560 NGM16 NGM16 NGM16 NGM16 NGM20 NGM25 NGM32 MG20-16 MG20-16 MG20-S MG20-S MG20 MG25 MG25 77721225P 77721825P 12 x 2.5 18 x 2.5 17.5 21.0 445 648 NGM32 NGM32 MG25 MG32 No Maximum Conductor Temperature 77720305P 77720405P 77720505P 77720705P 77721205P 77721805P 77722505P 90 degree C Bending Radius For flexing application: 15 times diameter unscreened Applications As power control or signal cables on machines, portable tools, conveying equipment & similar industrial applications. Quick Reference Current Capacities Page A20 Multi Core Deratings A21 Gland Options Page F8, F9 And F10 A17 Flexible Power Cables Flexible Control PVC Screened 0.3/0.5Kv Static - 30 to + 70 degree C Flexing -5 to + 70 degree C Rated Voltage 300/500 votls test voltage 2000 V Approx O.D. mm EMC Compliant Gland 77720205SC 77720305SC 77720405SC 77720505SC 77720705SC 77721205SC 77721805SC 77722505SC 77723005SC 2 x0.5 3 x 0.5 4 x 0.5 5 x 0.5 7 x 0.5 12 x 0.5 18 x 0.5 25 x 0.5 30 x 0.5 7.0 7.3 7.9 8.4 8.9 11.3 13.3 15.2 16.1 MG16EMCL MG16EMCL MG16EMCL MG16EMCL MG16EMCL MG20EMCL MG25EMCL MG25EMCL MG25EMCL 77720475SC 77720575SC 77720775SC 77721275SC 77721875SC 77722575SC 4 x 0.75 5 x 0.75 7 x 0.75 12 x 0.75 18 x 0.75 25 x 0.75 8.4 8.9 9.7 12.3 14.5 16.6 MG16EMCL MG16EMCL MG20EMCL MG20EMCL MG25EMCL MG25EMCL 77720301SC 77720401SC 77720501SC 77720701SC 77721201SC 77721801SC 77722501SC 77723401SC 77724101SC 3 x 1.0 4 x 1.0 5 x 1.0 7 x 1.0 12 x 1.0 18 x 1.0 25 x 1.0 34 x 1.0 41 x 1.0 8.2 8.7 9.5 10.2 13.3 15.5 17.5 20.3 22.0 MG16EMCL MG16EMCL MG20EMCL MG20EMCL MG25EMCL MG25EMCL MG32EMCL MG32EMCL MG40EMCL 77720215SC 77720315SC 77720415SC 77720515SC 77720715SC 77721215SC 77721815SC 77722515SC 77723415SC 77725015SC 2 x 1.5 3 x 1.5 4 x 1.5 5 x 1.5 7 x 1.5 12 x 1.5 18 x 1.5 25 x 1.5 34 x 1.5 50 x 1.5 8.5 8.9 9.6 10.3 11.3 14.8 17.2 20.1 22.8 27.1 MG16EMCL MG20EMCL MG20EMCL MG20EMCL MG20EMCL MG25EMCL MG32EMCL MG32EMCL MG40EMCL MG40EMCL 77720425SC 77720725SC 77721225SC 4 x 2.5 7 x 2.5 12 x 2.5 11.3 13.9 17.6 MG20EMCL MG25EMCL MG32EMCL re ma k *Fine wires Strands of bare copper wire, PVC core insulation, cores twisted in layers, black with consecutive numbering in white. One green yellow earth core. Outer sheath of PVC Compound Temperature Range No of Cores Section mm Square Part No Cable Construction Conductor Stranding No Fine Wire to VDE0295 and IEC 60228 Quick Reference Current Capacities Page A20 Multi Core De-ratings A21 Gland Options Page F9 A1 Flexible Power Cables re ma k Flexible Steel Braided Flexible Cable 0.6/1kV CABLE CONSTRUCTION TEMPERATURE RANGE: *Conductor fine wire strands of plain electrolytic copper wire for improved flexibility. * - 30 TO + 90 Degree C static *Insulation made of NBR elastomer compound specially designed for resistance to migration & cold flexibility. RATED VOLTAGE *0.6/1Kv *Inner sheath of specially formulated PVC, resistant to migration & highly flexibile in subzero temperatures. AS3147,IEC92-3,IEC92-353,IEC92350, IEC332-3 *Silicate powder lubricant between cores & inner sheath to reduce friction * - 18 TO + 90 Degree C flexible RELEVANT STANDARDS BENDING RADIUS 15 X DIAMETER APPLICATIONS Quick Reference No Current Capacities Page A21 Gland Options Page F9-F10 As power, control or signal cable on inland waterway & sea-going vessels. On conveyors, machine tools, cranes, earth moving equipment & other industrial applications where extra mechanical protection is required. Also suitable for wiring in hazardous locations [i.e chemical plants] Part No No of Cores x Section mm square Stranding Approx Outer Dia mm Approx Weight Kg/Km Metal Gland SWA Type 77770315 77770415 77770515 77770715 77771215 3x1.5 4x1.5 5x1.5 7x1.5 12x1.5 48/0.21 48/0.21 48/0.21 48/0.21 48/0.21 12.8 13.6 14.5 15.7 18.0 220 261 271 330 504 MGSWA20-16 MGSWA20-S MGSWA20-S MGSWA20 MGSWA20 77770325 77770425 77770725 3x2.5 4x2.5 7x2.5 80/0.21 80/0.21 80/0.21 14.2 15.2 17.5 260 295 448 MGSWA20-S MGSWA20-S MGSWA20 A18 A19 Flexible Power Cables Parallel Twin Flexible Cable 0.6/1kV Temperature Range: *Conductors of fine strands of Rated Voltage: re ma k Cable Construction *-30 to + 75 degrees C static -20 to +75 degrees C flexible electrolytic copper wire for extra flexibility. * 0.6/1Kv fixed wiring 450/750v for flexing *Insulation of cores in red/black or Red/ Blue Aflex NBR elastomer Relevant Standards: * VDE 0250, VDE472, AS3147, IEC 332-1 *Compound specially formulated for improved cold resistance. Application: *Sheathing of transparent PVC compound resistant to cold, abrasion, industrial oil and chemicals * Battery cable for use indoors and outdoors, in dry as well as wet locations on motorised vehicles, or battery powered equipment such as fork lifts, field conveyors etc. Also in high quality booster cables. *UV stabilised and flame retardant No Of Cores x mm Sq Stranding Approx Overall Dia. mm Bootlace Pins Uninsulated Ferrules Bellmouth Lug * Hole Size 77760225 77760204 77760206 77760210 77760216 77760225 77760235 77760250 77760270 2x 2.5mm 2 x 4.0mm 2 x 6.0mm 2 x 10.0mm 2 x 16.0mm 2 x 25.0mm 2 x 35.0mm 2 x 50.0mm 2 x70.0mm 80/0.21 127/0.21 190/0.21 318/0.21 504/0.21 770/0.21 1083/0.21 1558/0.21 2204/0.21 5.5x12 6.0x13 6.5x14 8.0x17 9.0x19 11.0x23 12.5x26 14.5x30 16.0x33 PBL025 PBL04 PBL06 PBL10 PBL16 PBL25 PBL35 PBL50 PBL70 CL025-* CL6-* CL6-*BM CL10-*BM CL16-*BM CL25-*BM CL35-*BM CL50-*BM CL70-*BM No Part No Quick Reference Current Capacities Page A21 Gland Options Page F8, F9, F10 A1 A20 Flexible Power Cables HO5 BQ-F 300/500V According to CENELEC HD 22.10 S1 07 BQ-F AS3116 0.6/1Kv Adapted to CENELEC HD 22.10 S1 Submersible EPR/PUR Flexible Cables Test voltage * Copper Conductor: Flexible, tinned up to 16mmsq Flexible, bare from 25mmsq upwards [acc. to IEC 228 Class 5 resp. Class 6 for single -core cables] * 300/500V : 2000 V,50 Hz, 5' * 0.6/1Kv : 2500 V,50 Hz, 5' Insulation: re ma k Construction EPDM, compound type Ei6 ass. to 22.1 S2 * Filling sheath: Halogen-free filling compound [except single-core cables] Outer Sheath; HD Halogen free polyurethane, compound type TMPU acc. to HD 22.10 S1 * Screening if applicable will be tinned copper braid. Pilot cores will be 1.5 mmsq Sheath colour * Orange [similar to RAL 2003] Core Colour *2 core : brown, blue *3 Core : brown, blue green/yellow *4 Core : black, blue, brown, green/yellow *5 Core : black,blue brown,blackgreen/yellow From 7Core-: black with numbers,green-yellow Temperature range * -40 up to +90 degree Cel Special characteristics * Extreme mechanical resistance [Abrasion-,tearing,-notch-,pressure & wear resistant] * Good reversed bending strength [min. 30000 reversed bendings under current acc. to VDE 0472, Part 603, Test H] * Good chemical resistance [against fuels, oils, grease, chemicals & sewage] * Resistant against enviromental factors[as ozone, UV, humidity, water] * Resistant against important temperature fluctuations * Flame retardant, halogen-free * Submersible down to 500m * Microbe & hydrolysis resistant No Quick Reference Current Capacities Page A21 Gland Options Page F8, F9, F10 H05 BQ-F 300/500 V R-EP-90 Relvent Standard AS3191 Part No No of Cores x-section mm sq Max Dia Wires mm Approx Overall Dia mm Approx Weight Kg/Km Maximum Amps Protected from Sun Nylon Gland Part No Metal Gland IP66 Metal Gland IP68 77730275 77730210 77733g75 77733g10 77734g75 77734g10 77735g75 77735g10 2 x 0.75 2 x 1.0 3 x 0.75 3 x 1.0 4 x 0.75 4 x 1.0 5 x 0.75 5 x 1.0 0.21 0.21 0.21 0.21 0.21 0.21 0.21 0.21 7.0 7.5 7.5 8.0 8.0 8.5 9.0 9.5 65 78 78 91 91 108 113 137 12 18 12 18 12 18 12 18 NGM16 NGM16 NGM16 NGM16 NGM16 NGM16 NGM20 NGM20 MG20-16 MG20-16 MG20-16 MG20-S MG20-S MG20-S MG20-S MG20-S MGS16 MGS16 MGS16 MGS16 MGS16 MGS16 MGS20 MGS20 A21 Flexible Power Cables Submersible EPR/PUR Flexible Cables 07 BQ-F AS3116 0.6/1Kv Adapted to CENELEC HD 22.10 S1 re ma k HO5 BQ-F 300/500V According to CENELEC HD 22.10 S1 H07 BQ-F R-EP-90 Relevent Standard AS3191, AS3116 0.6/1Kv No of Cores x-section mm sq Max Dia Strands mm Approx Overall Dia mm 77730215 77733G15 77733G25 77733G4 2 x 1.5 3 x 1.5 3 x 2.5 3x4 0.26 0.26 0.26 0.31 9.0 9.5 11.0 13.0 111 130 191 266 24 24 34 45 NGM16 MG20-S MGS20 NGM20 MG20-S MGS20 NGM20 MG20 MGS20 NGM25 MG20 MGS25 77734G15 77734G25 77734G4 77734G6 4 x 1.5 4 x 2.5 4x4 4x6 0.26 0.26 0.31 0.31 10.5 12.5 14.0 14.0 162 238 331 453 20 28 38 48 NGM20 NGM25 NGM25 NGM25 77735G15 77735G25 77735G4 77735G6 77735G10 77735G16 77735G025 77735G35 77735G50 5 x 1.5 5 x 2.5 5x4 5x6 5 x 10 5 x 16 5 x 25 5 x 35 5 x 50 0.26 0.26 0.31 0.31 0.41 0.41 0.41 0.41 0.41 11.5 13.5 16.0 18.0 23.1 26.5 33.5 38.0 43.5 195 291 411 559 951 1351 2169 2923 3945 20 28 38 48 66 88 120 145 180 NGM20 MG20 MGS20 NGM25 MG25 MGS25 NGM25 MG25 MGS32 NGM32 MG25 MGS32 NGM40 MG32 MGS40 NGM40 MG40 MGS40 NGM50 MG50-S MGS50 NGM63 MG50 MGS63 MG50 77737G15 77737G25 7 x 1.5 7 x 2.5 0.26 0.26 14.0 16.5 291 431 13 18 NGM25 NGM32 No Part No Approx Maximum Nylon Amps Gland Weight Kg/Km Protected Part No from Sun Metal Gland IP66 MG20 MG20 MG25 MG25 MG25 MG25 Metal Gland IP68 MGS20 MGS20 MGS25 MGS25 MGS25 MGS32 A1 A22 Flexible Power Cables Guide Only Refer to Australian Standards 3008.1.1 for complete listings and variations Technical Information For Flexible Cables Ratings and Capacities are based on Flexible Cables used In Flexing Applications and NOT Flexible Cables used for Fixed wiring applications. Refer to Australian Standards for these ratings AS 3008.1.1 re ma k Operating Temperatures 0 Of Conductors C Max Normal Use Permissible AS3008.1.1 1998 Table1 Limiting Temperatures For Insulated Cables Insulation Types Insulation Types Thermoplastic V-75 and HFI-75-TP V-90 and HFI-90-TP (AS 3008.1.1 For Conditions) V90 HT (AS 3008.1.1 For Conditions) 75 75 75 75 90 105 Elastomer R-EP-90, R-CPE-90, R-HF-90 and R-CSP-90 R-HF-110 and R-E-110 90 110 90 110 Cross Linked Polyethylene (XLPE) X-90 and X-HF-90 X-HF-110 90 110 90 110 AS3008.1.1 1998 Table16 Current Carrying Capacities Of Flexible Cords Conductor Size mm Number Of Layers Derating Factor 0.50 0.75 1.00 3.0 (Conditions Apply) 7.5 10.0 1 0.76 2 0.58 15.0 20.0 25.0 3 0.47 4 0.40 2 1.50 2.50 4.00 0 Based On Ambient Air Temperature of 25 C Current Carrying Capacities of 0.6/1 kV Flexible Cables Protected From Sun Exposed To Sun Single And 2 Core Single And 2 Core Single And 2 Core Single And 2 Core V75, V90 R-EP-90 R-CSP-90 V75, V90 R-EP-90 R-CSP-90 6.0 10.0 16.0 44 60 81 54 74 99 34 46 60 43 58 77 25.0 35.0 50.0 110 135 160 135 165 195 80 95 110 105 125 145 70.0 95.0 120.0 205 240 280 250 290 340 140 160 185 185 210 245 150.0 185.0 240.0* 320 360 425 390 440 510 215 240 275 280 315 365 No Conductor 2 Size mm AS3008.1.1 1998 Table15 2 Derating For Cords Wound On a Drum 0.5-4.0mm Current Carrying Capacity Amps Guide Only Refer to Australian Standards 3008.1.1 for complete listings and variations A23 Flexible Power Cables Guide Only Refer to Australian Standards 3008.1.1 for complete listings and variations Technical Information For Flexible Cables Current Carrying Capacities of 0.6/1 kV Flexible Cables Conductor 2 AS3008.1.1 1998 Table15 Size mm 6.0 10.0 16.0 25.0 35.0 50.0 70.0 95.0 120.0 150.0 185.0 240.0* Exposed To Sun re ma k Protected From Sun 3 And 4 Core 3 And 4 Core 3 And 4 Core 3 And 4 Core V75, V90 R-EP-90 R-CSP-90 V75, V90 R-EP-90 R-CSP-90 38 52 70 46 63 85 29 39 51 37 50 66 95 115 140 115 140 165 68 81 96 88 105 125 175 205 240 215 250 290 120 140 160 155 180 210 280 315 370 335 380 445 185 205 235 240 270 310 Current Carrying Capacities of R-S-150 Flexible Cords Conductor 2 0.50 0.75 1.00 1.50 2.50 4.00 6.00 10.00 16.00 25.00 35.00 19 24 28 37 50 67 87 120 165 215 265 15 20 23 28 38 50 67 90 119 160 194 No AS3008.1.1 1998 Table17 Size mm Two Single Core Or One 2 Core Three or Four Single Core or 3 or 4 core 15 20 24 31 43 58 74 105 140 185 230 AC Derating Factors For Multi Core Cables 2 Greater Than 5 Core 1.5 To 10.0 mm Number Of Cores Laying In air Laying In Ground 5 7 10 14 19 24 40 61 0.75 0.65 0.55 0.50 0.45 0.40 0.35 0.30 0.70 0.60 0.50 0.45 0.40 0.35 0.30 0.25 13 16 19 24 32 42 55 76 99 135 163 A1 Flexible Power Cables Guide Only Refer to Australian Standards 3008.1.1 for complete listings and variations Technical Information For Flexible Cables re ma k Three-Phase Voltage Drop At 50 Hz Of Multicore Flexible Cables And Cords With Copper Conductors Three Phase Voltage Drop At 50 Hz, mV/A.m Conductor 2 Size mm 0.5 0.75 1.0 1.5 2.5 4.0 6.0 10.0 16.0 25.0 35.0 50.0 70.0 95.0 120.0 150.0 185.0 240.0 300.0 400.0 600.0 0 0 Conductor Temperature C 45 Conductor Temperature C 60 75 90 Max 0.8 p.f Max 0.8 p.f Max 0.8 p.f Max 0.8 p.f 74.2 49.5 37.1 25.3 15.2 9.42 6.28 3.77 2.31 1.40 1.03 0.781 0.529 0.425 0.342 0.283 0.249 0.214 0.192 0.173 0.165 – 0.249 0.214 0.188 0.164 0.153 78.2 52.1 39.1 26.7 16.0 9.92 6.62 3.97 2.43 1.47 1.09 0.822 0.555 0.445 0.357 0.294 0.258 0.220 0.196 0.175 0.166 0.258 0.220 0.193 0.168 0.156 82.2 54.8 41.1 28.0 16.8 10.4 6.95 4.17 2.55 1.55 1.14 0.862 0.581 0.465 0.371 0.305 0.266 0.226 0.200 0.178 0.168 0.266 0.226 0.198 0.171 0.158 86.1 57.4 43.1 29.4 17.6 10.9 7.29 4.38 2.68 1.62 1.19 0.902 0.608 0.485 0.387 0.317 0.275 0.233 0.205 0.180 0.170 0.274 0.233 0.203 0.174 0.161 AC Resistance At 50 Hz Of Flexible Cables And Cords With Copper Conductors Conductor Size mm2 Multi Core Cables 0 0 Conductor Temperature C 45 60 75 90 45 60 75 90 42.8 28.6 21.4 14.6 8.76 5.44 3.62 2.17 1.33 0.803 0.589 0.442 0.293 0.229 0.178 0.140 0.116 0.0909 0.0729 0.0558 45.1 30.1 22.6 15.4 9.23 5.73 3.82 2.29 1.40 0.846 0.621 0.466 0.309 0.242 0.188 0.147 0.122 0.0955 0.0764 0.0583 47.4 31.6 23.7 16.2 9.70 6.02 4.01 2.41 1.47 0.889 0.652 0.489 0.324 0.254 0.197 0.155 0.128 0.100 0.0800 0.0609 49.7 33.2 24.9 17.0 10.2 6.31 4.21 2.52 1.54 0.932 0.684 0.513 0.340 0.266 0.206 0.162 0.134 0.105 0.0836 0.0634 42.8 28.6 21.4 14.6 8.76 5.44 3.62 2.17 1.33 0.803 0.589 0.442 0.293 0.230 0.179 0.141 0.117 0.0919 0.0741 0.0573 45.1 30.1 22.6 15.4 9.23 5.73 3.82 2.29 1.40 0.846 0.621 0.466 0.309 0.242 0.188 0.148 0.123 0.0965 0.0776 0.0598 47.4 31.6 23.7 16.2 9.70 6.02 4.01 2.41 1.47 0.889 0.652 0.490 0.325 0.254 0.198 0.155 0.129 0.101 0.0811 0.0623 49.7 33.2 24.9 17.0 10.2 6.31 4.21 2.52 1.54 0.932 0.684 0.513 0.340 0.266 0.207 0.163 0.135 0.106 0.0847 0.0648 No 0.5 0.75 1.0 1.5 2.5 4.0 6.0 10.0 16.0 25.0 35.0 50.0 70.0 95.0 120.0 150.0 185.0 240.0 300.0 400.0 Single Core Cables Conductor Temperature C For AC Resistance Of Tinned Copper Conductors Multiply Copper Value By 1.01 Guide Only Refer to Australian Standards 3008.1.1 for complete listings and variations A24 A25 Flexible Power Cables Guide Only Refer to Australian Standards 3008.1.1 for complete listings and variations Technical Information For Flexible Cables re ma k Current Carrying Capacities of 3 Single Core 0.6/1 kV Flexible Cables R-EP-90 Insulation As Per AS/NZS 3008.1.1:1998 Table 7 Single Double Insulated Cables In Fixed Application Spaced Spaced from Surface Touching 1 1.5 2.5 4 6 10 16 25 35 50 70 95 120 150 185 240 300 400 19 25 35 46 59 81 110 145 180 220 280 350 410 470 550 660 770 900 16 21 30 40 50 69 92 125 155 190 240 300 350 405 470 560 650 760 16 20 28 37 47 65 86 115 145 175 225 280 325 375 435 520 600 700 No Conductor Size mm Nonmetallic wiring enclosure in air 14 18 25 33 42 58 78 110 125 155 190 230 270 310 355 420 485 560 Please refer to Australian Standards for full conditions and notes which refer to this table Guide Only Refer to Australian Standards 3008.1.1 for complete listings and variations A1 Flexible Power Cables Guide Only Refer to Australian Standards 3008.1.1 for complete listings and variations Technical Information re ma k For Flexible Cables Current Carrying Capacities of 3 Single Core 0.6/1 kV Flexible Cables R-E-110 Insulation As Per AS/NZS 3008.1.1:1998 Table 8 Single Double Insulated Cables In Fixed Application Conductor Size mm Spaced from Surface Touching 24 31 43 57 73 99 130 175 220 265 340 420 490 570 660 790 910 1070 21 27 38 50 63 86 115 155 190 230 290 365 420 485 560 670 780 910 20 25 36 47 59 81 105 145 175 215 270 340 395 455 530 630 730 850 No 1 1.5 2.5 4 6 10 16 25 35 50 70 95 120 150 185 240 300 400 Spaced Nonmetallic wiring enclosure in air 17 22 32 41 51 71 93 125 150 180 235 285 335 380 450 550 630 720 Please refer to Australian Standards for full conditions and notes which refer to this table A26 A27 Flexible Power Cables Guide Only Refer to Australian Standards 3008.1.1 for complete listings and variations Technical Information For Flexible Cables re ma k Comparison of Current Ratings for Sheath Types As Per Australian Standards Application: Touching Mounted to Tray etc Conductor Size mm (1) V75, V90 (2) R-EP-90 (3) R-E-110 13 16 20 16 20 25 23 28 36 31 37 47 40 47 59 54 65 81 72 86 105 97 115 145 120 145 175 145 175 215 185 225 270 230 280 340 265 325 395 150 310 375 455 185 355 435 530 240 425 520 630 300 490 600 730 400 570 700 850 1 1.5 2.5 4 6 10 16 25 35 50 70 95 No 120 Please refer to Australian Standards for full conditions and information for the above ratings A1 Flexible Power Cables re ma k This catalogue only covers the standard range of cables supplied by Noremak Industries. Noremak can have cables manufactured custom cables for the Australian electronics industry with many of these products being used locally and exported on a world wide Noremak is capable of having products and cables manufactured to AS9002 and to Australian Standards including Austel, and can provide cables to UL approval for those cables involved in export manufacturing. Noremak Industries has a close relationship with many cable manufactures in Australia and overseas and is able to have special purpose cables manufactured to requirements and specialises in small run quantities. These cables can be composed of any mixtures of conductors, pairs, coaxial cables and a variety of strength members and other elements depending on application A few of examples which can be supplied UNDER WATER VIDEO CAMERA CABLES SEWER INSPECTION CABLES MOBILE PHONE SYSTEM CABLES DENTAL CABLES No METAL DETECTOR CABLES Please contact Noremak Industries for your cable requirements for Power and Data applications. Noremak can have cables produced to your requirements in surprisingly short runs and in surprisingly quick turn around times. We can also have leads and special application plugs manufacturing capabilities. Noremak Industries Pty Ltd 12 Princess Street Beverley SA 5009 Phone 08 8244 7288 Fax 08 8244 7299 email: [email protected] A28
© Copyright 2025 Paperzz