MD, MS Manual Man ifold Sys tems M anualm anifolds are designed to regulate com pressed gases in high pressure cylinders (up to 3,000 psig)and are idealform anifold applications not requiring autom atic changeover from the service to the secondary bank.The M D Series duplex m anifold is designed form anual changeoverof2 banks ofcylinders.The M S series sim plex m anifold system allow s m anifolding ofan unlim ited num berofcylinders in a single bank.This system is often used as a high pressure reserve forbulk,portable bulk and gas generatorsystem s. specifications MD,MS s e r i e s tManual Systems tMaximum w orking pressure: 3 0 0 0 psig tManifold O utlet:1/2 ” N PT male t2 4 ” flexible stainless steel braided pigtails w ith check valves. C heck valve is at header end of pigtail for all gases except O xygen. N ote: H elium and H ydrogen manifolds shipped w ith synthetic fiber braided pigtails M D – 4– 4 Ex am ple: M D–4–4 = C O 2 (4=C G A–320) M anifold for4 C ylinders tIndividual header valves at each cylinder location (units w ith 4 cylinders or larger-all gases except O xygen) tH eaders constructed of 1/2 ” brass pipe and tees tA cetylene manifolds shipped complete w ith dry flashback arrestor, relief valve and connecting piping. H ydraulic Flashback arrestors are available as an option for an additional charge M S– 9– 4 tO ptional safety kits, flash arrestor and relief valve available for Liquefied Fuel gases Ex am ple: M S–9–4 = O xygen (9=C G A–540) M anifold for4 cylinders tH eater Kits available for C arbon D ioxide and N itrous O xide gases tModel RM regulator included for most gas services. Note: RD M Series used for O xygen tA n alarm can be added to non fuel gas MD systems to signal changeover from service to reserve banks by adding items W ME-4 -9 pressure sw itch,W MS-1 -9 7 adaptor, W MS-9 -2 5 C pow er source and BIA -3 remote A / V alarm. HO W TO O R DER Specify: Control Type (V)–Service (W)–Number of Cy Exam ple 1:MD –9–12V represents MD w ith oxygen gas service and a vert Exam ple 2:MSH P–7–6 represents MSH P w ith nitrogen gas service w ith a st C O N TRO L TYPE (V) G A S SERVIC E (W ) MD / MS Most gases: 2 0 –16 0 psig A cetylene: (0 –15 psig) LPG : (0 –4 5 psig) (1 ) (1 A ) (2 ) (3 ) (4 ) (5 ) (6 ) (6 A ) (7 ) (7 A ) (8 ) (9 ) (1 0 ) MD H P / MSH P (only available for non–fuel gas services) Most gases:14 0 –3 0 0 psig O xygen:14 0 –4 5 0 psig A cetylene (PO L) A cetylene (C ommercial) C ompressed A ir A rgon C arbon D ioxide H elium H ydrogen A rgon/ Methane Mixtures N itrogen Industrial A ir/ N itrogen O P N itrous O xide O xygen Liquefied Fuel G ases (LPG ) # O F C YL’S (X) CG CG CG CG CG CG CG CG CG CG CG CG CG A –5 1 0 A –3 0 0 A –3 4 6 A –5 8 0 A –3 2 0 A –5 8 0 A –3 5 0 A –3 5 0 A –5 8 0 A –5 9 0 A –3 2 6 A –5 4 0 A –5 1 0 N ote: Different regulators m ay be substituted to achieve higherdelivery pressures on allcontroltypes. 10 For m ore inform ation, callW estern C ustom er Service at1-800 -783 -7890 D es ig n Len g t h s TO TA L N O . O F C Y LIN DE R S 2 3 4 5 6 7 8 MS-Standard (1 0 ” C enters) O verall Manifold Length 2 ’–9 ” (.8 4 m) 3 ’–7 ” (1 .0 9 m) 4 ’–5 ” (1 .3 5 m) 5 ’–3 ” (1 .6 0 m) 6 ’–1 ” (1 .8 5 m) 7 ’–0 ” (2 .1 3 m) 7 ’–1 0 ” (2 .3 9 m) MS-Staggered D esign (5 ” C enters) O verall Manifold Length 2 ’–4 ” (.7 4 m) 2 ’–9 ” (.8 4 m) 3 ’–2 ” (.9 7 m) 3 ’–7 ” (1 .0 9 m) 4 ’–0 ” (1 .2 2 m) 4 ’–5 ” (1 .3 5 m) 4 ’–1 0 ” (1 .4 7 m) MS-Vertical C rossover and C rossover (1 0 ” C enters)O verall Manifold Length 1 ’–1 1 ” (.5 8 m) N /A 2 ’–9 ” (.8 4 m) N /A 3 ’–7 ” (1 .0 9 m) N /A 4 ’–5 (1 .3 5 m) MS-Standard (1 3 ” C enters) O verall Manifold Length 3 ’–0 ” (.9 1 m) 4 ’–1 ” (1 .2 2 m) 5 ’–2 ” (1 .5 7 m) 6 ’–3 ” (1 .9 1 m) 7 ’–4 ” (2 .2 4 m) 8 ’–5 ” (2 .5 7 m) 9 ’–6 ” (2 .9 0 m) MS-Staggered D esign (6 .5 ” C enters) O verall Manifold Length 2 ’–5 .5 ” (.7 5 m) 3 ’–0 ” (.9 1 m) 3 ’–6 .5 ” (1 .0 8 m) 4 ’–1 ” (1 .2 5 m) 4 ’–7 .5 ” (1 .4 1 m) 5 ’–2 ” (1 .5 7 m) 5 ’–8 .5 ” (1 .7 4 m) MS-Vertical C rossover and C rossover (1 3 ” C enters) O verall Manifold Length 1 ’–1 1 ” (.5 8 m) N /A 3 ’–0 ” (.9 1 m) N /A 4 ’–1 ” (1 .2 5 m) N /A 5 ’–2 ” (1 .5 7 m) 2 4 6 8 12 14 MD -Standard (1 0 ” C enters) O verall Manifold Length 2 ’–4 ” (.7 1 m) 4 ’–4 ” (1 .3 2 m) 6 ’–0 ” (1 .8 3 m) 7 ’–8 ” (2 .3 4 m) 9 ’–4 ” (2 .8 5 m) 1 1 ’–0 ” (3 .3 5 m) 1 2 ’–8 ” (3 .8 6 m) MD -Staggered D esign (5 ” C enters) O verall Manifold Length 2 ’–4 ” (.7 1 m) 3 ’–6 ” (1 .0 7 m) 4 ’–4 ” (1 .3 2 m) 5 ’–2 ” (1 .5 7 m) 6 ’–0 ” (1 .8 3 m) 6 ’–1 0 ” (2 .0 8 m) 7 ’–8 ” (2 .3 4 m) N /A 2 ’–8 ” (.8 1 m) N /A 4 ’–4 ” (1 .3 2 m) N /A 6 ’–0 ” (1 .8 3 m) N /A MD -Standard (1 3 ” C enters) O verall Manifold Length 2 ’–4 ” (.7 1 m) 4 ’–9 ” (1 .4 7 1 m) 7 ’–0 ” (2 .1 3 m) 9 ’–2 ” (2 .7 9 m) 1 1 ’–4 ” (3 .4 5 m) 1 3 ’–6 ” (4 .1 1 m) 1 5 ’–8 ” (4 .7 7 m) MD -Staggered D esign (6 .5 ” C enters) O verall Manifold Length 2 ’–4 ” (.7 1 m) 3 ’–9 ” (1 .1 4 m) 4 ’–1 0 ” (1 .4 7 m) 5 ’–1 1 ” (1 .8 0 m) 7 ’–0 ” (2 .1 3 m) 8 ’–1 ” (2 .4 6 m) 9 ’–2 ” (2 .7 9 m) N /A 2 ’–8 ” (.8 1 m) N /A 4 ’–1 0 ” (1 .4 7 m) N /A 7 ’–0 ” (2 .1 3 m) N /A TO TA L N O . O F C Y LIN DE R MD -Vertical C rossover and C rossover (1 0 ” C enters)O verall Manifold Length MD -Vertical C rossover and C rossover (1 3 ” C enters) O verall Manifold Length 10 ylinders (X)–Header Configuration (Y)–Mounting (Z) rticalcrossover bank of 6 cylinders per side w hich is m ounted on the w all. standard header configuration of 6 cylinders w hich is m ounted on the w all. H EA D ER C O N FIG U RATIO N (Y) MO U N TIN G (Z) B LA NK –Standard 10” on C enter 13 ” on C enter for A cetylene & LPG S–Staggered 5 ” on C enter 6 .5 ” on C enter for A cetylene & LPG V–Vertical C rossover 1 0 ” on C enter or 1 3 ” on C enter for A cetylene & LPG C–C rossover (Floor Mount O nly) 1 0 ” on C enter or 1 3 ” on C enter for A cetylene & LPG B LA NK = W all mount F = Floor mounted 11
© Copyright 2026 Paperzz