HPSTM Products Series Vapor Sublimation Trap OPERATION AND MAINTENANCE MANUAL HPSTM Products Series Trap Vapor Sublimation Trap September 1997 PART #WCTRAP-MAN REV. A Vapor Sublimation Trap Part # WCTRAP-XXX-XXX-X-XXX Serial # __ __ __ __ __ __ Please fill in these numbers and have them readily available when calling for service or additional information. (The part number can be found on your packing slip, and both the part number and serial number are located on the bottom side of the housing.) For more information or literature, contact: MKS Instruments Inc., HPSTM Products, Inc. 5330 Sterling Drive Boulder, CO 80301 USA Phone: 303-449-9861 800-345-1967 FAX: 303-442-6880 © 1997 by MKS Instruments Inc., HPSTM Products, Inc. All rights reserved. Viton is a registered trademark of E.I. du Pontde Nemours & Co. VacuComp is a trademark of MKS Instruments, HPSTM Products, Inc Vapor Sublimation Trap Table of Contents Table of Contents Package Contents ..................................................................... 1 Symbols Used in this Manual .................................................... 1 Safety Information...................................................................... 2 Symbols Used in this Manual (English) .............................................. Symboles utilisés dans ce manuel (Français) ..................................... In dieser Betriebsanleitung vorkommende Symbole (Deutsch) ........... Símbolos Usados en el Manual (Español) .......................................... Definition of Symbols Found on the Unit (English) .............................. Définition des symboles apparaissant sur l’appareil (Français) ........... 2 2 3 3 4 4 Symbol Definitions .................................................................... 4 Símbolos que Aparecen en la Unidad (Español) ................................. 4 Definitionen der am Gerät angebrachten Symbole (Deutsch) .............. 4 Safety Precautions .................................................................... 5 Chemical Handling .............................................................................. 5 Ammonium Chloride .................................................................................................. 5 Aluminum Chloride ..................................................................................................... 5 Feature and Control Locations .................................................. 6 Specifications ............................................................................ 8 Typical Applications for the Vapor Sublimation Trap .................. 9 About the HPSTM Vapor Sublimation Trap ................................ 10 Installing the Vapor Sublimation Trap ...................................... 11 Orienting the Trap ............................................................................... 11 Locating the Trap ................................................................................11 Wet Pump .......................................................................................... 11 Dry Pump ........................................................................................... 12 Using Cooling Water ........................................................................... 13 Maintaining the Vapor Sublimation Trap .................................. 14 Cleaning the Trap ................................................................................14 NH4Cl ................................................................................................. 14 AlCl3 ..................................................................................................14 Drying the Trap ...................................................................................15 Waste Management ........................................................................... 15 Accessories / Part Replacement ............................................. 16 Product Warranty ..................................................................... 17 Notes ....................................................................................... 18 Vapor Sublimation Trap Appendix A: ......................... A.1 Vapor Pressure Curves ...... A.1 NH4Cl AlCl3 A.1 A.2 Vapor Sublimation Trap Package Contents Before unpacking your Vapor Sublimation Trap, check all surfaces of the packing material for shipping damage. Please be sure that your Vapor Trap package contains these items: t 1 Trap unit t 1 HPS™ Vapor Sublimation Trap User's Manual Inspect the Trap for visible evidence of damage. If it has been damaged in shipping, notify the carrier immediately. Keep all shipping materials and packaging for claim verification. Do not return the product to HPSTM. If any items are missing from the package, call HPSTM Customer Service at 1-303-449-9861 or 1-800-345-1967. Symbols Used in this Manual The first two symbols, that may be located on your HPSTM, Vapor Simulation Trap identify critical safety concerns. They are used throughout this manual to further define the safety concerns associated with the product. The last two symbols identify other information in this manual that is essential or useful in achieving optimal performance from the HPSTM, Vapor Simulation Trap. Vapor Sublimation Trap 1 Safety Information Symbols Used in this Manual (English) Definitions of CAUTION and NOTE messages used throughout the manual. 22 Symboles utilisés dans ce manuel (Français) Définition des indications ATTENTION et REMARQUE utilisées dans ce manuel. CAUTION: Refer to accompanying documents. ISO 3864, No. B.3.1 ATTENTION: Se reporter à la documentation. ISO 3864, No. B.3.1 This sign denotes a hazard. It calls attention to a procedure, practice, condition, or the like, which, if not correctly performed or adhered to, could result in injury to personnel. L’indication signale un danger potentiel. Elle est destinée à attirer l’attention sur une procédure, une utilisation, une situation ou toute autre chose présentant un risque de blessure en cas d’exécution incorrecte ou de non-respect des consignes. This sign denotes a hazard. It calls attention to an operating procedure, practice, or the like, which, if not correctly performed or adhered to, could result in damage to or destruction of all or part of the product. L’indication signale un danger potentiel. Elle est destinée à attirer l’attention sur une procédure, une utilisation, une situation ou toute autre chose présentant un risque d’endommagement ou de dégât d’une partie ou de la totalité de l’appareil en cas d’exécution incorrecte ou de non-respect des consignes. This sign denotes important information. It calls attention to a procedure, practice, condition, or the like, which is essential to highlight. L’indication REMARQUE signale des informations importantes. Elle est destinée à attirer l’attention sur une procédure, une utilisation, une situation ou toute autre chose présentant un intérêt particulier. Vapor Sublimation Trap In dieser Betriebsanleitung vorkommende Symbole (Deutsch) Símbolos Usados en el Manual (Español) Definiton der mit VORICHT! und HINWEIS überschriebenen Abschnitte in dieser Betriebsanleitung. Definiciones de los mensajes de PRECAUCIÓN y OBSERVACIÓN usados en el manual. VORSICHT! Bitte Begleitdokumente lesen! ISO 3864, Nr. B.3.1 PRECAUCIÓN: Consultar los documentos adjuntos. ISO 3864, N.° B.3.1 Das Symbol VORSICHT! weist auf eine Gefahrenquelle hin. Es macht auf einen Arbeitsablauf, eine Arbeitsweise, einen Zustand oder eine sonstige Gegebenheit aufmerksam, deren unsachgemäße Ausführung bzw. Ungenügende Berücksichtigung zu Körperverletzung führen kann. Esto símbolo indica un riesgo. Pone de relieve un procedimiento, práctica, condición, etc., que, de no realizarse u observarse correctamente, podría causar lesiones a los empleados. Das Symbol VORSICHT! weist auf eine Gefahrenquelle hin. Es macht auf einen Bedienungsablauf, eine Arbeitsweise oder eine sonstige Gegebenheit aufmerksam, deren unsachgemäße Ausführung bzw. Ungenügende Berücksichtigung zu einer Beschädigung oder Zerstörung des Produkts oder von Teilen des Produkts führen kann. Esto símbolo indica un riesgo. Pone de relieve un procedimiento, práctica, etc., de tipo operativo que, de no realizarse u observarse correctamente, podría causar desperfectos al instrumento, o llegar incluso a causar su destrucción total o parcial. Das Symbol HINWEIS weist auf eine wichtige Mitteilung hin, die auf einen Arbeitsablauf, eine Arbeitsweise, einen Zustand oder eine sonstige Gegebenheit von besonderer Wichtigkeit aufmerksam macht. Esto símbolo indica información de importancia. Pone de relieve un procedimiento, práctica, condición, etc., cuyo conocimiento resulta esencial. Vapor Sublimation Trap 3 Symbol Definitions Definition of Symbols Found on the Unit (English) Definitionen der am Gerät angebrachten Symbole (Deutsch) Caution refer to accompanying documents ISO 3864, No. B.3.1 Vorsicht! Bitte Begleitdokumente lesen! ISO 3864, Nr. B.3.1 Caution hot surface IEC 417, No. 5041 Vorsicht! Heiße Fläche! IEC 417, Nr. 5041 Frame or Chassis IEC 417, No. 5020 Rahmen oder Chassis IEC 417, Nr. 5020 Class II Equipment IEC 417, No. 5172-a Geräteklasse II IEC 417, Nr. 5172-a Définition des symboles Símbolos que Aparecen apparaissant sur en la Unidad (Español) l’appareil (Français) Attention se reporter à la documentation ISO 3864, No. B.3.1 Precaución Consultar los documentos adjuntos ISO 3864, N.° B.3.1 Attention surface brûlante IEC 417, No. 5041 Precaución Superficie caliente IEC 417, N.° 5041 Masse, Châssis IEC 417, No. 5020 Caja o chasis IEC 417, N.° 5020 Matériel de la Classe II IEC 417, No. 5172-a Equipo de clase II IEC 417, N.° 5172-a 44 Vapor Sublimation Trap Safety Precautions The following general safety precautions must be observed during all phases of operation of this product. Failure to comply with these precautions or with specific warnings elsewhere in this manual violates safety standards of intended use and may impair the protection provided by the equipment. HPS Division of MKS Instruments, Inc. assumes no liability for the customer’s failure to comply with these requirements. Chemical Handling Refer to your Material Safety Data Sheets (MSDS). Ammonium Chloride NH4Cl may be harmful by inhalation, ingestion, or skin absorption. Causes eye and skin irritation. Do not breathe its dust. Avoid contact with eyes, skin, and clothing. When working with NH4Cl, be sure to wear a NIOSH/MSHA approved respirator, chemical resistant gloves, safety goggles, and other protective clothing. Wash up thoroughly after handling the chemical. NH4Cl is corrosive and soluble in water. Aluminum Chloride AlCl3 is highly toxic. It may be harmful by inhalation, ingestion, or skin absorption. Do not breathe the vapors and use only in a chemical fume hood. Avoid contact with eyes, skin, and clothing. When working with AlCl3, be sure to wear a NIOSH/MSHA approved respirator, chemical resistant gloves, safety goggles, and other protective clothing. Wash up thoroughly after handling the chemical. AlCl3 is corrosive and reacts violently with water. Vapor Sublimation Trap 5 Feature and Control Locations x x y NW 50 Angle Trap y NW 50 Offset, Inline Trap x x y NW 80 Angle Trap y NW 80 Off-Set, Inline Trap 66 Vapor Sublimation Trap x y x NW 100 Angle Trap y NW 100 Off-Set, Inline Trap DIMENSIONS IN. (MM) INLINE NW 50 NW 80 NW 100 ANGLE NW 50 NW 80 NW 100 6" BODY 8"BODY X Y X 9.5 10.5 9.2 12.3 (241) (267) (234) (312) Y 8.0 9.3 7.8 11.0 (203) (236) (198) (279) 7.3 9.3 7.0 11.0 (185) (236) (178) (279) X Y X Y 7.0 7.8 6.7 9.5 (178) (198) (170) (241) 5.3 6.0 5.0 7.8 (135) (152) (127) (198) 5.0 5.0 4.3 6.8 (127) (127) (109) (173) Vapor Sublimation Trap 7 Specifications Body Diameter 6 or 8 in. Capacity 6-inch 3.0 lb (1.4 kg) NH4Cl 4.5 lb (2.0 kg) AlCl3 8-inch 10.0 lb (4.5 kg) NH4Cl 15.0 lb (6.8 kg) AlCl3 Efficiency > 99 % Flow Conductance (Viscous Flow Region) C (L/sec) = 20.74p p – pressure in mTorr Pressure Drop Across Trap (Viscous Flow Region) p (mTorr) = 812 Q/p2 Q – gas flow rate in sccm p – pressure in mTorr Cooling Water Flow Rate > 6 gal/hr (400 mL/min) Cooling Water Temperature < 86°F (30°C), lower is better Materials 304 and 316 series stainless steel, elastomer seal Flanges/Interface MF 100, MF 80 KF 100, KF 80, KF 50 Reducers are required and available for MF 63 and KF 40 pump lines Typical Dry Weight with MF Flanges 6-inch 16.5 lb (7.5 kg) 8-inch 28.0 lb (12.7 kg) Design and/or specifications subject to change without notice. 88 Vapor Sublimation Trap Typical Applications for the Vapor Sublimation Trap vv Collect ammonium chloride (NH4Cl) in a silicon nitride CVD system vv Collect aluminum chloride (AlCl3) in an aluminum etching system vv Trap condensable vapors that begin to solidify above ambient temperature Vapor Sublimation Trap 9 About the HPSTM Vapor Sublimation Trap CHEMICAL REACTION PROCESSES, such as Chemical Vapor Deposition (CVD), are carried out under high temperature and vacuum conditions such that a high reaction rate can be reached and particulate contamination lessened. Ammonium chloride (NH4Cl) by-product from silicon nitride CVD and aluminum chloride (AlCl3) by-product from aluminum etching solidify above ambient temperature. Resulting clogged pump lines and contaminated systems require frequent maintenance. The HPS™ Vapor Sublimation Trap collects these condensable vapors, significantly reducing maintenance and increasing throughput. Its efficiency rating of more than 99% and high capacity ensure less down time and higher product yield, making it especially desirable to the semiconductor industry. The Trap is designed with two stages — the first for high capacity, the second for attaining high trapping efficiency. The first stage, at the entrance of the Trap, has a higher volume for collecting condensable by-product than comparable traps. In fact, its capacity is approximately 5 to 10 times greater than other traps of the same class. Several perforated stainless steel cones are placed in the second stage to maximize the heat transfer between the gas and cooling surface while maintaining the necessary high flow conductance. This is a final “polish” of the gas flow. 10 10 Vapor Sublimation Trap Installing the Vapor Sublimation Trap Orienting the Trap The orientation of the Trap has a negligible effect on the performance of the Trap as the condensed ammonium chloride and aluminum chloride are very hard, dense materials. The Vapor Trap must be installed in the correct flow direction, indicated by the arrow sign on the Trap body, to attain its highest capacity and efficiency. Locating the Trap Figure 1 at the bottom and figure 2 on the next page show Trap installation suggestions for a wet pump and a dry pump, respectively. Shaded areas represent heated lines or components, while unshaded areas represent unheated or cold lines or components. Wet Pump As shown in figure 1A, when the Trap is installed next to a wet pump and not in a clean room, replacement of the Trap is greatly simplified. Figure 1B shows the Trap located just downstream of a heated isolation valve. This locale option shortens the length of heated line. In any case, always install the Trap upstream of a wet pump. A B Figure 1: Installation options with a wet pump Vapor Sublimation Trap 11 A B C D Figure 2: Installation options with a dry pump. Dry Pump Though a trap is not required with a dry pump (figure 2A), one should be used to improve the overall performance of your system and process yield. If the Trap is installed downstream of the pump, as in figure 2B, the Scrubber load is reduced dramatically and heated lines post-Trap are not needed since most of the condensable vapors have been collected in the Trap. In figures 2C and 2D, the Trap is installed upstream of the pump to prevent solidified vapors from clogging or damaging it. This option also reduces the amount of ballast nitrogen dramatically, thus improving both the performance and lifetime of the dry pump. With a Trap, you can use an unheated roots blower to achieve higher pumping speed and lower the ultimate pressure in a CVD system. General rules for locating the Trap are: v v v 12 12 Apply heat to the pump line between the reaction chamber and the Trap, Place a heated isolation valve between the reaction chamber and the Trap, and Install the Trap more than 3 feet away from the exit of the reaction chamber. Vapor Sublimation Trap Using Cooling Water Cooling water should be provided to attain high efficiency from the Trap. House water or refrigerated water is acceptable. The water flow rate should be kept at approximately 6 gallons per hour or higher. The temperature of the cooling water should be less than 30°C, a lower water temperature is preferred. Vapor pressure curves for both ammonium chloride and aluminum chloride are shown in Appendix A. These curves show at what temperatures heated lines located before the Trap operate most efficiently as a function of pressure, as well as the partial pressure of the condensable vapor leaving the Trap. Vapor Sublimation Trap 13 Maintaining the Vapor Sublimation Trap Since the Vapor Trap is used to collect such by-products as solidified ammonium chloride (NH4Cl) or aluminum chloride (AlCl3), the conductance of the Trap will decrease after a period of operation. Eventually, the Trap will limit gas flow rate due to the condensed solid, and periodical cleaning in a water bath with follow-up baking is necessary. Cleaning the Trap NH4Cl Since NH 4Cl is soluble in water, clean the Trap in a water bath. Mechanical cleaning is not recommended since solidified NH4 Cl is a very strong, harsh material. Do not attempt to separate internal from trap body prior to cleaning. Failing to do so may result in significant damage to the trap. 1 Insert the Trap into a fresh, circulating warm water bath. Since the solubility of NH4Cl in water is a function of temperature, cleaning time will be shortened if warm water is used. Lukewarm water (<60°C) is recommended. 2 Continuously circulate the water bath during the cleaning process to lower the acidity of the solution for minimal corrosion. A fresh water pressurized rinse is preferred. Do not use hot water. HCl acid may be generated during the dissolving process prematurely corroding the Trap body. 3 When removing internasal from body, be sure to pull internal out axially do not spin or twist the internal, or damage to the coils could result. AlCl3 If collecting AlCl3 in the Trap, cold water (<30°C) should be used to clean it since the solubility for AlCl3 is much higher than for NH4Cl. High levels of HCl acid will be generated if hot water is used. AlCl3 reacts violently with water. Special safety procedures should be followed during the cleaning process. 14 14 Vapor Sublimation Trap Drying the Trap Place the Trap in an oven to dry for about 2 hours after cleaning in the water bath. Set the oven temperature to less than 120°C. A higher temperature may vaporize the water concealed in the cooling coils by the quick-release couplings. Since large amounts of by-product are collected in the Trap, it may take several hours to complete the whole cleaning and drying process. It is highly recommended that a spare Trap be available and used to replace the other during cleaning to minimize downtime. Water vapor contamination, due to environment exposure, will also be reduced. Waste Management Please consult with your local waste management authorities for proper disposal of hazardous chemical waste. Vapor Sublimation Trap 15 Accessories / Part Replacement Part # Replacement Internal 6-inch Body 8-inch Body 100004954 100009608 Bonnet Flange Seal For 6-inch Body Viton® Silicone 100003597 100004790 For 8-inch Body Viton® Silicone 100762020 100009637 1 Self-Sealing, Quick-Release H2O Fitting Straight, Qty 2 90° Elbow, Qty 2 100004980 100004981 Please call HPSTM' Customer Service Department at 1-303-449-9861 or 1-800-345-1967 to order any of these accessories or to receive catalogs for other HPSTM Products. 16 16 Vapor Sublimation Trap Product Warranty Extent of the Warranty MKS Instruments, Inc., warrants the HPS TM Vapor Sublimation Trap and its accessories to be free from defects in materials and workmanship for one (1) year from the date of shipment by HPSTM or authorized representative to the original purchaser (PURCHASER). Any product or parts of the product repaired or replaced by HPSTM under this warranty are warranted only for the remaining unexpired part of its one (1) year original warranty period. After expiration of the applicable warranty period, the PURCHASER shall be charged HPSTM’ current prices for parts and labor, plus any transportation for any repairs or replacement. ALL EXPRESS AND IMPLIED WARRANTIES, INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, ARE LIMITED TO THE WARRANTY PERIOD. NO WARRANTIES, EXPRESS OR IMPLIED, WILL APPLY AFTER THIS PERIOD. Warranty Service The obligations of HPSTM under this warranty shall be at its option: (1) to repair, replace, or adjust the product so that it meets applicable product specifications published by HPSTM or (2) to refund the purchase price. What Is Not Covered The product is subject to above terms only if located in the country of the seller from whom the product was purchased. The above warranties do not apply to: I. Damages or malfunctions due to failure to provide reasonable and necessary maintenance in accordance with HPSTM operating instructions. II. Damages or malfunctions due to chemical or electrolytic influences or use of the product in working environments outside the specification. III. Fuses and all expendable items which by their nature or limited lifetime may not function for a year. If such items fail to give reasonable service for a reasonable period of time within the warranty period of the product; they will, at the option of HPSTM, be repaired or replaced. IV. Defects or damages caused by modifications and repairs effected by the original PURCHASER or third parties not authorized in the manual. Condition of Returned Products HPSTM will not accept for repair, replacement, or credit any product which is asserted to be defective by the PURCHASER, or any product for which paid or unpaid service is desired, if the product is contaminated with potentially corrosive, reactive, harmful, or radioactive materials, gases, or chemicals. When products are used with toxic chemicals, or in an atmosphere that is dangerous to the health of humans, or is environmentally unsafe, it is the responsibility of the PURCHASER to have the product cleaned by an independent agency skilled and approved in the handling and cleaning of contaminated materials before the product will be accepted by HPSTM for repair and/or replacement. In the course of implementing this policy, HPSTM Customer Service Personnel may inquire of the PURCHASER whether the product has been contaminated with or exposed to potentially corrosive, reactive, harmful, or radioactive materials, gases, or chemicals when the PURCHASER requests a return authorization. Notwithstanding such inquiries, it is the responsibility of the PURCHASER to ensure that no products are returned to HPSTM which have been contaminated in the aforementioned manner. Other Rights and Remedies I. These remedies are exclusive. HPSTM SHALL NOT BE LIABLE FOR CONSEQUENTIAL DAMAGES, FOR ANTICIPATED OR LOST PROFITS, INCIDENTAL DAMAGES OR LOSS OF TIME, OR OTHER LOSSES INCURRED BY THE PURCHASER OR BY ANY THIRD PARTY IN CONNECTION WITH THE PRODUCT COVERED BY THIS WARRANTY, OR OTHERWISE. Some states do not allow exclusion or limitation of incidental or consequential damage or do not allow the limitation on how long an implied warranty lasts. If such laws apply, the limitations or exclusions expressed herein may not apply to PURCHASER. II. Unless otherwise explicitly agreed in writing, it is understood that these are the only written warranties given by HPSTM. Any statements made by any persons, including representatives of HPSTM, which are inconsistent or in conflict with the terms of the warranty shall not be binding on HPSTM unless reduced to writing and approved by an authorized officer of HPSTM. III. This warranty gives PURCHASER specific legal rights, and PURCHASER may also have other rights which vary from state to state. IV. For HPSTM products sold outside of the U.S., contact your MKS representative for warranty information and service. Warranty Performance To obtain warranty satisfaction, contact the following: MKS Instruments Inc., HPSTM Products, Inc., 5330 Sterling Drive, Boulder, CO 80301, USA, at phone number (303) 449-9861. You may be required to present proof of original purchase. Vapor Sublimation Trap 17 Notes 18 18 Vapor Sublimation Trap Vapor Sublimation Trap 19 Appendix A: Vapor Pressure Curves NH4Cl 103 102 Solid Phase 101 Pressure (Torr) 100 Vapor Phase 10-1 10-2 10-3 10-4 10-5 0 50 100 150 200 250 300 350 Temperature (°C) Vapor Sublimation Trap A.1 AlCl3 103 102 Solid Phase 101 Pressure (Torr) 100 10-1 Vapor Phase 10-2 10-3 10-4 10-5 0 A.2 50 Vapor Sublimation Trap 100 Temperature (°C) 150 200
© Copyright 2026 Paperzz