WT Installation Instructions

PHOENIX
7
INSTALLATION INSTRUCTIONS AND REPAIR PARTS LIST FOR
GENERAL USE WEATHER-TIGHT FIXTURES
REGULAR ROUGH SERVICE, PORTABLE ROUGH SERVICE & MARINE/ROUGH SERVICE FIXTURES
STURDILITE7 ModelsWT-120/500, WT-120/56/500, WT-120/500P, WT-120/56/500P,
WT-12/56/300P, WT-12/56/300P-14
MOUNTING (For Stationary Models Only)
Fasten fixture with four 3/8 inch (9.5mm) bolts through holes
provided in mounting base. Do not mount on unsupported cap or
house roof. Attach near corner supports or use adequate subbase. Avoid mounting on light-weight cross members of booms or
derricks which will vibrate or flex excessively. In addition to normal
(base down) mounting, fixture may be attached in a pendant or
cantilever manner.
Lamping is accomplished through the hinged cover glass
assembly. For fixtures with PAR 56 lamps, loosen two (2) screws
on lamp support ring and rotate lamp retaining ring free from
screws. Bring lamp partially out of fixture and detach socket. To
install new lamp, just reverse the steps for lamp removal. When
pushing socket onto lamp prongs of PAR 56 lamps, do not use
excessive force. If socket goes on hard, try aligning contacts
inside with slots in porcelain body by means of knife blade.
LAMPING
When re-lamping, it is recommended that the cover glass be
cleaned to maintain fixture efficiency. (See CLEANING, Page 4.)
CAUTION
WARNING
TURN OFF FIXTURE AND ALLOW IT TO COOL
BEFORE ATTEMPTING TO RE-LAMP.
WT-120/500P & WT-120/56/500P PLUG INTO A GFCI
PROTECTED RECEPTACLE ONLY.
LAMP SUGGESTIONS for AWT@ Series Fixtures
Fixture Model
Number
WT 120/56/500P
WT 120/56/500
WT 120/500P
WT 120/500
WT 12/56/300P
WT 12/56/300P-14
Volts
Watts
Description
INC= Incandescent
HL=Halogen Cycle
Approx.
Initial
Lumens
Beam
Spread
in
Degrees
Average
Max. CP
Central
Cone
Lamp
-ANSINumber
PHOENIX
Catalog
Number
8.000
20 x 42
34 x 66
15 x 32
49.000
18.000
90.000
Q500 PAR 56/MFL
Q500 PAR 56/WFL
Q500 PAR 56/NSP
4202400
4202500
4202600
24.000
10.000
70.000
300 PAR 56/MFL
300 PAR 56/WFL
300 PAR 56/NSP
4200400
4200300
4200600
Type of
Lamp
Type of
Base
PAR 56
Mogul
End
Prong
PAR 56
Mogul
End
Prong
3.840
20 x 35
30 x 60
15 x 20
3.650
6.500
115
115
2.200
4.700
6.000
60 x 40
12.700
120V
500W
HL/Medium Flood
HL/Wide Flood
HL/Narrow Spot
120V
300W
INC/Medium Flood
INC/Wide Flood
INC/Narrow Spot
120V
300W
500W
INC/Medium Flood
INC/Medium Flood
R-40
Mogul
Screw
Base
12/300
INC/Wide Flood
PAR 56
Screw
Term
300/3FL/MS
500R/3FL/MS
4200500
4201200
25A PAR 56/WFL
4202200
N5485100F-1
WARNING
When using outdoor use portable lamps, basic safety precautions should always be followed to reduce the risk of
fire, electrical shock, and personal injury, including the following:
a) Use only three-wire outdoor extension cords that have three-prong grounding plugs and grounding receptacles
that accept the appliance's plug.
b) Ground Fault Circuit Interrupter (GFCI) protection should be provided on the circuit(s) or outlet(s) to be used for
wet location portable lamp. Receptacles are available having built-in GFCI protection and are able to be used for
this measure of safety.
c) Use only with an extension cord for outdoor use, such as an extension cord of cord type SW, SW-A, SOW,
SOW-A, STW, STW-A, STOW, STOW-A, SJW, SJW-A, SJOW, SJOW-A, SJTW, SJTW-A, or SJTOW, SJTOW-A
CAUTION
RISK OF ELECTRICAL SHOCK!
Do not use with extension cord near water or where water may accumulate. Keep lamp at least 16 feet from pools
and spas. Keep plugs and receptacles dry.
READ ALL INSTRUCTIONS
SAVE THESE INSTRUCTIONS
N 5485100F-2
81996 C PHOENIX PRODUCTS COMPANY, INC.
REPAIR PARTS LIST
ITEM NO.
DESCRIPTION
PART NO.
ITEM NO.
DESCRIPTION
PART NO.
1
Phoenix Mounting Base Assembly
WT 120/500
WT 120/56/500
1800100
13
Shell Mounting Hardware
WT 120/500
WT 120/56/500
1073100
2
Aluminum Base
WT 120/500P
WT 120/56/500P
WT 12/56/300P
WT 12/56/300P-14
7513600
14
Shell Mounting Hardware
WT 120/500P
WT 120/56/500P
WT 12/56/300P
WT 12/56/300P-14
1073200
3
Base Assembly
MS 120/500
1817100
16
Harp Mounting Hardware
WT 120/500
WT 120/56/500
1053300
17
Harp Mounting Hardware
WT 120/500P
WT 120/56/500P
WT 12/56/300P
WT 12/56/300P-14
1073500
19
Cord Grip
WT 120/500
WT 120/56/500
WT 120/500P
WT 120/56/500P
4032800
4
Shell Assembly
WT 120/500
1072400
WT 120/56/500
1072500
WT 120/500P
1072600
WT 120/56/500P
1072700
WT 12/56/300P
WT 12/56/300P-14
1072800
1072900
5
Harp for AWT@ Series
2401801
6
Door for AWT@ Series
2662402
7
Cord Assembly
WT 120/500
8
9
4033100
20
Watertight Plug Cap
WT 120/500P
WT 120/56/500P
4044300
21
Rubber Foot w/Hardware
1073600
22
Lamp Support Kit
WT 120/500
WT 120/500P
2022500
23
Lamp Retainer Kit
WT 12/56/300P-14
WT 12/56/300P-14P
1090180
4114701
WT 120/56/500
4114400
WT 120/500P
WT 120/56/500P
4114500
WT 12/56/300P
4115100
WT 12/56/300P-14
4117600
Mogul Screw Lamp Socket
WT 120/500
WT 120/500P
WT 12/56/300P
WT 12/56/300P-14
1090190
4502200
WT 120/56/500P
4500100
10
Cover Glass
4602900
11
Gasket
5003800
12
Latch Fastener with Screws
For AWT@ Series
1090210
WT 120/56/500P
1090220
24
Handle Kit
WT 120/500P
WT 120/56/500P
WT 12/56/300P-14
WT 12/56/300P-14P
1090230
25
Lens Retainer Kit
1090240
Mogul-End-Prong Lamp Socket
WT 120/56/500
WT 120/56/500
1160120
N5485100F-3
REPAIR PARTS ILLUSTRATION
N 5485100F-4
81996 C PHOENIX PRODUCTS COMPANY, INC.
All wiring should be done by licensed
electricians in accordance with State &
WIRING:
Models WT 120/500, WT 120/56/500
These fixtures are prewired with a 4 foot (1.22m)
three conductor electrical cord Apigtail@ for wiring
to suitable power source. The green conductor is
grounded to the fixture and must be connected to
a positive ground. DO NOT CONNECT GREEN
WIRE TO POWER SOURCE.
CAUTION
Local codes plus NEC (National Electric
Code Standards).
Improper installation or use may result
in serious injury.
Models WT 120/500P and WT 120/56/500P
CLEANING:
These fixtures are prewired with a stub three
conductor electrical cord with attached watertight
male twist-lock connector for connection to
suitable power source with a mating watertight
female twist-lock connector.
Models WT 12/56/300P and WT 12/56/300P-14
These fixtures are prewired with a 10 foot (3.05m)
and a 14 foot (4.27m) (respectively) two
conductor electrical cord for wiring to suitable
power source.
If the interior surface of the cover glass becomes
dirty it is recommended that it be cleaned to
maintain maximum light output. The glass may
be cleaned with any non-abrasive conventional
glass cleaner.
To prevent the cover glass gasket from sticking at
sealing surfaces it is recommended that a liquid
silicone release agent be used. Best results are
achieved when one application on the gasket is
wiped dry (to clean the surface) and then a
second application allowed to remain wet when
cover glass assembly is replaced during relamping.
One Year Products Warranty C (Limited Type)
Phoenix Products Company warrants its product against defects in material and workmanship. Without charge,
Phoenix Products Company will either repair or replace (Phoenix Products Company reserves the right to decide
between repair or replacement) any properly installed Phoenix Products Company manufactured product which fails
under normal operating conditions within one year from date of installation, provided it is returned to the factory (after
authorization), transportation prepaid, and our inspection determines it to be defective under terms of this warranty.
The warranty covers only equipment manufactured by Phoenix Products Company and does not extend to
transportation, installation or replacement charges at buyer=s facility; nor does it apply to any other equipment
of another manufacturer used in conjunction with Phoenix Products Company equipment. No other warranty,
expressed or implied, exists beyond that included in this statement.
PHOENIX PRODUCTS COMPANY, INC.
8711 West Port Avenue ! Milwaukee, WI 53224 U.S.A.
Phone: 414/973-3300
FAX: 414/973-3210
www.phoenixproducts.com
N5485100F-5