MP Meter-Pak™ Meter Centers Class 4141 Catalog 4141CT0701 2008 MP44125 MP86200 CONTENTS Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Page Product Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 General and Application Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 Wiring Diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 MP Meter-Pak™ Meter Centers Product Description PRODUCT DESCRIPTION Square D® brand MP Meter-Pak meter centers from Schneider Electric offer a wide range of solutions for multi-metering applications: MPH66125 with Horn Bypass • • • UL® Listed NEMA Type 3R construction • Meter socket jaws, constructed of tin-plated copper, are spring reinforced on MP devices • Lever type bypass meter socket jaws are spring reinforced and equipped with jaw release • Stainless steel cover hasps and latches meet tough coastal utility sealing requirements • Barrel lock provisions on all ringless devices Meets EUSERC standards 9-inch meter center spacing allows for more sockets per device creating lighter, more compact branch enclosures MP Meter-Pak Meter Centers For 2- to 6-unit apartment buildings or light commercial applications. • • • • • Surface and semi-flush mounting Suitable only for use as service equipment Main bus ratings range from 200–800 A 125, 200, and 225 A (2 to 4 positions) tenant circuit breaker versions Four meter socket configurations available: — Ring type four-jaw without bypass — Ringless type with 5th jaw without bypass — Ringless type with 5th jaw and horn bypass — Ringless type with 5th jaw and lever bypass with jaw release • 120/240 Vac, 1φ3W or 120/208 Vac, 1φ3W (derived from a 208Y/120 Vac, 3φ4W network) MPH33125 2 © 2008 Schneider Electric All Rights Reserved 03/2008 MP Meter-Pak™ Meter Centers Product Description Short Circuit Current Rating Selection Process 1. Review local utility requirements to ensure that metering equipment meets their standards. 2. Check with local utility to determine available fault current at the meter center. 3. Use the Short Circuit Current Ratings (SCCR) table below to: a. Read down to select SCCR equal to or greater than desired rating. b. Read across to select Tenant Circuit Breaker type. 4. With information obtained from Step 3, turn to the appropriate selection pages to determine catalog numbers for Meter-Pak Device and Tenant Circuit Breakers. UL Listed Meter Center Short Circuit Current Ratings (SCCR) 10,000, 22,000, 25,000. 42,000, 65,000 and 100,000 AIR Short Circuit Current Rating (RMS Symmetrical Amperes at 240 Vac Maximum)1 MP Meter-Pak Meter Centers Tenant Circuit Breakers2 QO (125 A max., 2-pole) 10,000 AIR 3 QOM2-MM (200 A max., 2-pole) QBP-TM (70–225 A max., 2-pole) 22,000 AIR QO-VH (125 A max., 2-pole) 3 QOM2-MVH (200 A max., 2-pole) 25,000 AIR 3 QDP-TM (70–225 A max., 2-pole) 42,000 AIR 3 QOH (125 A max., 2-pole) 65,000 AIR 3 QGP-TM (70–225 A max., 2-pole) 100,000 AIR 3 QJP-TM (70–225 A max, 2-pole) MP Branch Compartments Service Disconnects (6 Maximum) Transformer Main Lugs Load Center (Typical) MP Main Lugs Compartment 1 2 3 Meter center short circuit current rating is equal to the lowest short circuit current rating given in the table for any circuit breaker installed in any meter panelboard in the meter center. When slider type manual circuit closers are installed, the meter center short circuit current rating is limited to 10,000 RMS symmetrical amperes. AIR = Amperes Interrupting Rating. 3 03/2008 © 2008 Schneider Electric All Rights Reserved MP Meter-Pak™ Meter Centers Table of Contents Table of Contents MP METER-PAK™ METER CENTERS Application Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5 125 A Maximum MP Meter-Pak Meter Center Configurations . . . . . . . . .6 200 A Maximum MP Meter-Pak Meter Center Configurations . . . . . . . . .6 225 A Maximum MP Meter-Pak Meter Center Configurations . . . . . . . . .6 Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7 Service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7 Mains Rating. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7 Branch Circuit Breaker Provisions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7 Meter Sockets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7 Meter Socket Covers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9 Utility Pull Box Cover. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11 Customer/Tenant Compartment Cover . . . . . . . . . . . . . . . . . . . . . . . . . .11 Mounting Channel. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11 Rotating Mounting Feet. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11 Top Endwall Configurations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12 125 A Maximum MP Meter-Pak Meter Center Top Endwalls . . . . . . . . .12 200 and 225 A Maximum MP Meter-Pak Meter Center Top Endwalls . .12 Semi-Flush Flange Kits. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12 MP Meter-Center Hub and Knockout Configurations . . . . . . . . . . . . . . .13 Main Lugs Section Service Conductor Termination Data . . . . . . . . . . . .14 Alternate Lug Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14 NEMA/EUSERC Lug Landing Kit . . . . . . . . . . . . . . . . . . . . . . . . . . .14–15 Tenant Circuit Breaker Terminal Data . . . . . . . . . . . . . . . . . . . . . . . . . . .16 Service Grounding/Load Neutral and Equipment Grounding Termination Data. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17 Hinged Rain Channel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17 Underground Service Wireway . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17–18 Catalog Number Description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19 Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20 Dimensions and Knockouts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22 Wiring Diagrams. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .31 4 © 2008 Schneider Electric All Rights Reserved 03/2008 MP Meter-Pak™ Meter Centers Application Data Application Data MP22125 (shown) MPR22125, MPH22125 (Sealing Rings not shown) MP33125, MPR33125, MPH33125 (shown) MP44125 (shown) MPR44125, MPH44125 MP55125, MPR55125, MPH55125, MP66125, MPR66125, MPH66125 (shown) (Top Left Position Omitted on 5-Position Units) MP42200 (shown) MPR42200, MPH42200 MP43200, MPR43200 MPH43200 (shown) 5 03/2008 © 2008 Schneider Electric All Rights Reserved MP Meter-Pak™ Meter Centers Application Data 125 A Maximum MP Meter-Pak™ Meter Center Configurations • Ring-type MP supplied with 4-jaw meter socket without bypass (5th jaw and manual slider type bypass kits can be ordered separately and field-installed). • Ringless-type MPR supplied with 5-jaw meter socket without bypass (horn-type bypass kits can be ordered separately and field-installed). • Ringless-type MPH supplied with 5-jaw meter socket with horn-type bypass. • Both ring- and ringless-type units have provisions for mounting 2-pole, plug-on type QO®, QO-VH, or QOH circuit breakers. 200 A Maximum MP Meter-Pak Meter Center Configurations MP64200, MPR64200, MPH64200 (shown) • Ring-type MP supplied with 4-jaw meter socket without bypass (5-jaw and manual slider type bypass kits can be ordered separately and field-installed). • Ringless-type MPR supplied with 5-jaw meter socket without bypass (horn-type bypass kits can be ordered separately and field-installed). • Ringless-type MPH supplied with 5-jaw meter socket with horn-type bypass. • Both ring- and ringless-type units have provisions for mounting 2-pole, bolt-on type QOM2-MM or QOM2-MVH circuit breakers. 225 A Maximum MP Meter-Pak Meter Center Configurations MP85200, MPR85200, MPH85200, MP86200 (shown), MPR86200, MPH86200 (Top Left Position Omitted on 5-Position Units) • Ringless-type MPL supplied with 5-jaw meter sockets with lever bypass and jaw release. • MPL devices have provisions for mounting QBP-TM, QDP-TM, QGP-TM, or QJP-TM 2-pole bolt-on type circuit breakers. MPL32225, MPL53225 (shown), MPL64225 6 © 2008 Schneider Electric All Rights Reserved 03/2008 MP Meter-Pak™ Meter Centers Application Data Type • • • • Enclosures are indoor/rainproof NEMA Type 3R • Designed to be wall mounted only, not suitable for use as floor standing equipment • All unmetered conductor compartments are sealable by the utility company • Finish: ANSI gray, baked powder coat epoxy electro-deposited over cleaned phosphatized steel • UL Listed under File E-6294 MP, MPH and MPR available in 2-, 3-, 4-, 5-, or 6-position configurations MPL available in 2-, 3-, or 4-position configurations Suitable only for use as service entrance equipment (cannot be fed from an upstream service disconnect) Service • • MPH66125 120/240 Vac, 1φ3W 120/208 Vac, 1φ3W (derived from a 208Y/120 Vac, 3φ4W network) Mains Ratings 125 A Maximum MP Meter-Pak Meter Centers 200 A (2-position), 300 A (3-position), 400 A (4-position), 500 A (5-position), and 600 A (6-position) main bus ratings. 200 A Maximum MP Meter-Pak Meter Centers 400 A (2- and 3-position), 600 A (4-position) and 800 A (5- and 6-position) main bus ratings. 225 A Maximum MP Meter-Pak Meter Centers 400 A Main Lugs 350 A (2-position), 500 A (3-position), 600 A (4-position) main bus ratings. Branch Circuit Breaker Provisions 125 A Maximum MP Meter-Pak Meter Centers Accepts 40–125 A, 2-pole, plug-on type QO, QO-VH, or QOH circuit breakers. (Order circuit breakers separately.) UL® Listed meter center short circuit current rating (RMS symmetrical amperes) equal to the lowest interrupting rating of installed tenant circuit breaker. Ampere Rating QO Plug-On Mounting Base QO2100 Plug-On Circuit Breaker Installed 10,000 AIR 120/240 Vac 22,000 AIR 120/240 Vac 42,000 AIR 120/240 Vac 40 QO240 QO240VH QOH240 50 QO250 QO250VH QOH250 60 QO260 QO260VH QOH260 70 QO270 QO270VH QOH270 80 QO280 QO280VH QOH280 90 QO290 QO290VH QOH290 100 QO2100 QO2100VH QOH2100 125 QO2125 QO2125VH QOH2125 NOTE: For load center series ratings used downstream from metering equipment, refer to the following Data Bulletins: 4100DB0301 and 2700DB9901. 7 03/2008 © 2008 Schneider Electric All Rights Reserved MP Meter-Pak™ Meter Centers Application Data 200 A Maximum MP Meter-Pak Meter Centers Accepts 100–200 A, 2-pole, bolt-on type QOM2-MM or QOM2-MVH circuit breakers. (Order circuit breakers separately.) UL Listed meter center short circuit current rating (RMS symmetrical amperes) equal to the lowest interrupting rating of tenant circuit breaker installed. Ampere Rating 10,000 AIR 120/240 Vac 22,000 AIR 120/240 Vac 100 QOM2100MM QOM2100MVH 125 QOM2125MM QOM2125MVH 150 QOM2150MM QOM2150MVH 175 QOM2175MM QOM2175MVH 200 QOM2200MM QOM2200MVH QOM2-MM or QOM2-MVH Bolt-On Mounting Base NOTE: For load center series ratings used downstream from metering equipment, refer to Data Bulletins: 4100DB0301 and 2700DB9901. 225 A Maximum MP Meter-Pak Meter Centers Accepts 70–225 A, 2-pole, bolt-on type, QBP-TM, QDP-TM, QGP-TM, or QJP-TM circuit breakers. Also accepts 40–60 A, 2-pole, plug-on type QO, QO-VH or QOH circuit breakers; but requires the use of EZM125QOA adapter kit. (Order circuit breakers and adapter kit separately). QOM2200MVH Bolt-On Circuit Breaker Installed UL Listed meter center short circuit current rating (RMS symmetrical amperes) equal to the lowest interrupting rating of tenant circuit breaker installed. Ampere Rating QDP22200TM 2-Pole, Bolt-on Type Circuit Breaker 10,000 AIR 120/240 Vac 25,000 AIR 120/240 Vac 65,000 AIR 120/240 Vac 100,000 AIR 120/240 Vac 40 QO240 1 QO240VH 1 2 QOH240 1 3 — 50 QO250 1 QO250VH 1 2 QOH250 1 3 — 60 QO260 1 QO260VH 1 2 QOH260 1 3 — 70 QBP22070TM QDP22070TM QGP22070TM QJP22070TM 80 QBP22080TM QDP22080TM QGP22080TM QJP22080TM 90 QBP22090TM QDP22090TM QGP22090TM QJP22090TM 100 QBP22100TM QDP22100TM QGP22100TM QJP22100TM 110 QBP22110TM QDP22110TM QGP22110TM QJP22110TM 125 QBP22125TM QDP22125TM QGP22125TM QJP22125TM 150 QBP22150TM QDP22150TM QGP22150TM QJP22150TM 175 QBP22175TM QDP22175TM QGP22175TM QJP22175TM 200 QBP22200TM QDP22200TM QGP22200TM QJP22200TM 225 QBP22225TM QDP22225TM QGP22225TM QJP22225TM 1 Requires use of EZM125QOA adapter (order separately). 2 QOVH tenant circuit breakers are rated 22,000 AIR at 120/240 Vac. 3 QOH tenant circuit breakers are rated 42,000 AIR at 120/240 Vac. Meter Sockets Standard Meter Socket Configurations Optional 5th Jaw Kit Installed on Ring-Type Device Ringless-Type MPH Includes 5-Jaw Meter Socket and Horn Bypass • • Rated 200 A continuous duty. • • Thermoset polyester with fiberglass reinforced base assembly. • • • Ring-type MP supplied with 4-jaw meter socket without bypass. • Ringless-type MPL supplied with 5-jaw meter socket with lever bypass and jaw release. Front removable spring reinforced jaws equipped with line and load side blade guides. 5th jaw supplied factory-installed on ringless-type MPH and MPR in the 9 o'clock position, 5th jaw can be moved to the 3 or 6 o’clock position as required. Ringless-type MPR supplied with 5-jaw meter socket without bypass. Ringless-type MPH supplied with 5-jaw meter socket with horn-type bypass. 8 © 2008 Schneider Electric All Rights Reserved 03/2008 MP Meter-Pak™ Meter Centers Application Data Optional Meter Socket • 5th jaw kit (catalog number 5J) can be field-installed on ring-type MP at the 3, 6, or 9 o’clock position and is required for 120/208 Vac, 1φ3W, service (derived from a 208Y/120 Vac 3φ4W network). One kit required per meter socket, order separately. • Horn-type bypass kit, catalog number MMHB, can be field-installed on ringless-type MPR. One kit required per meter socket, order separately. • Manual slider type bypass kit, catalog number MM125MB (for top position only on 125 A, 2-position ring-type MP) or MM200MB (for 125 A and 200 A ring-type MP). One kit required per meter socket, order separately for field-installation. NOTE: Manual slider type bypass kits limit meter center equipment short circuit current rating to 10,000 RMS symmetrical amperes. Ring-Type MP 4-Jaw Meter Socket without Bypass Meter Socket Covers Ring-Type MP Meter Socket Cover Individual Ring-Type Meter Socket Cover • Individual meter socket cover provided for each meter socket. • Cover cannot be removed with meter installed in meter socket. • Seal ring is required to secure base of meter onto rim provided on meter socket cover. • Aluminum snap-type seal ring (catalog number 29209-100-01) is standard on all ring-type MP meter socket covers. Optional Meter Socket Sealing Rings for Type MP Manual Slider-Type Bypass, Closed Position MM125MB, MM200MB (shown) • Stainless steel snap-type sealing ring (catalog number ARP00026). Order separately for field-installation. • Aluminum screw-type sealing ring (catalog number 29008W). Order separately for field-installation. Snap-Type Sealing Ring Screw-Type Sealing Ring Manual Slider-Type Bypass, Open Position MM125MB, MM200MB (shown) 9 03/2008 © 2008 Schneider Electric All Rights Reserved MP Meter-Pak™ Meter Centers Application Data Ringless-Type MPH, MPL, and MPR Meter Socket Covers • • Individual meter socket cover provided for each meter socket. • Ringless meter socket covers are each supplied with a stainless steel latch and hasp to accommodate utility seals including lead wire seals, barrel locks, ribbon seals, padlocks, and snap-type seals. • Ringless meter socket covers are also supplied with a 3/4-inch knockout to accommodate front-entry barrel locks. • Barrel lock bracket located behind 3/4-inch knockout in each ringless meter socket cover. • Barrel lock head protector kit (catalog number MMBLC) includes ferrule, lock nut, and seal cap to accommodate 1-inch long barrel lock (barrel lock not included). Individual Ringless-Type Meter Socket Cover Base of meter is supported by brackets extending from meter socket base assembly. Meter socket cover is installed over meter to seal meter base to socket. Support Brackets for Base of Meter Stainless Steel Latch and Hasp, Ringless Meter Socket Cover Barrel Lock Installed Front Entry through Knockout in Ringless Meter Socket Cover (Reverse View) Barrel Lock Head Protector Kit MMBLC Installed through Knockout in Ringless Meter Socket Cover 10 © 2008 Schneider Electric All Rights Reserved 03/2008 MP Meter-Pak™ Meter Centers Application Data Utility Pull Box Cover • Supplied with handles on 3- through 6-position 125 A maximum, 2- through 6-position 200 A maximum, and 2- through 4-position 225 A maximum Meter-Pak meter center units. • Supplied with rotating locking hasp to accommodate utility seals including lead wire seals, barrel locks, ribbon seals, padlocks, and snap-type seals. Lifting Handles for Pull Box Cover Hasp with Cover Installed Rotating Locking Hasp Customer/Tenant Compartment Cover Circuit Breaker Cover, Closed • • Removable without interfering with meter covers. • Supplied with vertical rainproof tenant circuit breaker covers, one per meter socket. Supplied with rotating locking hasp to accommodate a padlock (see rotating locking hasp above). Tenant Circuit Breaker Covers • • • Constructed of impact resistant thermoplastic Provisions for padlocking or sealing Equipped with latch Mounting Channel Tenant Compartment Circuit Breaker Cover Circuit Breaker Cover, Open • Mounting channel supplied with 3- through 6-position 125 A maximum and all 200 A and 2- through 4-position 225 A maximum units. • Mounting flange is formed as a part of the top endwall to permit easy installation. • Mount the channel to the wall at proper height. Hang unit on channel from mounting flange. Rotating Mounting Bracket • • • • Mounting Channel Permanently attached to save time Easily moved for mounting hole drilling after marking Accommodates slight mounting hole misalignment Used for permanent mounting of device to wall Rotating Mounting Bracket 11 03/2008 © 2008 Schneider Electric All Rights Reserved MP Meter-Pak™ Meter Centers Application Data Top Endwall Configurations 125 A Maximum MP, MPR, and MPH Meter-Pak Meter Center Top Endwalls Closing Plate ACP (supplied) 2-Position 125 A Top Endwall Type A Hub Installed 2-Position 125 A Top Endwall • 2-position unit has utility compartment provisions for mounting one type A hub for use with 1- through 2.5-inch size conduit. Closing plate (Catalog Number ACP) supplied, order hub separately. • 3- and 4-position units have utility compartment provisions for mounting one type A-L hub for use with 2- through 4-inch size conduit. Closing plate (Catalog Number ACPL) supplied, order hub separately. • 5- and 6-position units have utility compartment provisions for mounting two type A-L hubs for use with 2- through 4-inch size conduits. Two ACPL closing plates supplied, order hubs separately. 200 and 225 A Maximum MP, MPR, and MPH Meter-Pak Meter Center Top Endwalls 2- through 6-position units have utility compartment provisions for mounting two type A-L hubs for use with 2- through 4-inch size conduit. Two ACPL closing plates supplied, order hubs separately. Semi-Flush Flange Kits Closing Plate ACPL (supplied) 3- and 4-Position 125 A Top Endwall Prior to installation, semi-flush flange kits can be ordered separately for field modification. (Refer to instructions included in kits for complete directions.) To drill enclosure top endwall and box sides to secure mounting flanges: 1. Drill 5/16-inch diameter clearance holes at center punched marks provided and secure flanges with 1/4-20 mounting hardware provided. 2. Secure mounting flanges of enclosure to stud wall on three sides (top, left, and right). 3. Cover mounting flanges with building paper and caulk to seal between enclosure and building paper. 225 A Maximum MPL Meter-Pak Meter Center Top Endwalls Type A-L Hub Installed 3- and 4-Position 125 A Top Endwall 2- through 4-position units have utility compartment provisions for mounting two type A-L hubs for use with 2- through 4-inch size conduit. Two ACPL closing plates supplied, order hubs separately. Semi-Flush Flange Kit Description Two Closing Plates ACPL (supplied) 5- and 6-Position 125 A Top Endwall and 2- through 6-Position 200 A Top Endwall 2- through 4-Position 225 A Top Endwall Two Type A-L Hubs Installed 5- and 6-Position 125 A Top Endwall and 2- through 6-Position 200 A Top Endwall 2- through 4-Position 225 A Top Endwall Catalog Number 125 A Maximum 2-Position MPSF12 125 A Maximum 3- and 4-Position MPSF14 125 A Maximum 5- and 6-Position MPSF16 200 A Maximum 2- and 3-Position MPSF23 200 A Maximum 4-Position MPSF24 200 A Maximum 5- and 6-Position MPSF26 Semi-Flush Flange Kit MPSF23 12 © 2008 Schneider Electric All Rights Reserved 03/2008 MP Meter-Pak™ Meter Centers Application Data Knockouts Conduit Size Hole Diameter Symbol in. [mm] in. [mm] A 0.50 13 0.88 22 B 0.75 19 1.25 29 C 1.00 25 1.38 35 D 1.25 32 1.75 44 E 1.50 38 2.00 51 F 2.00 51 2.50 64 G 2.50 64 3.00 76 H 3.00 76 3.63 92 I 3.50 89 4.19 105 J 4.00 102 4.63 117 MP Meter-Pak Meter Center Hub and Knockout Configurations Maximum Tenant Circuit Breaker Ampere Rating and Number of Positions Top Endwall Pull Box Compartment Catalog Number 125 A 2-Position MP22125 MPH22125 MPR22125 125 A 3-Position MP33125 MPH33125 MPR33125 125 A 4-Position MP44125 MPH44125 MPR44125 125 A 5-Position MP55125 MPH55125 MPR55125 125 A 6-Position MP66125 MPH66125 MPR66125 200 A 2-Position MP42200 MPH42200 MPR42200 200 A 3-Position MP43200 MPH43200 MPR43200 200 A 4-Position MP64200 MPH64200 MPR64200 200 A 5-Position MP85200 MPH85200 MPR85200 Bottom Endwall Closing Plate(s) Supplied Factory-Installed Hub Provisions Pull Box Compartment Knockout and Hub Provisions (1) ACP (1) Type A (1) Type A Hub or (1) B300 Hub or (1) D, F, G, and (1) A Tenant Circuit Breaker Compartment Knockouts (2) C, D, F and (1) A Box Back Tenant Circuit Breaker Compartment Knockouts (2) C, D, F 1 (1) ACPL (1) Type A–L (2) Type A–L Hubs or (2) E, F, G, H (4) C, D, F and (1) A, B Note: One knockout is and (1) A, B provided with I and J rings. (2) ACPL (2) Type A–L (3) C, D, F and (2) Type A–L Hubs or (1) A, B (2) G, H, I, J Provided per and (1) A compartment. (3) C, D, F Provided per compartment. (2) ACPL (2) Type A–L (2) Type A–L Hubs or (4) C, D, F and (2) G, H, I, J (1) A, B and (1) A (3) C, D, F (2) ACPL (2) Type A–L (2) Type A–L Hubs or (4) C, D, F (2) G, H, I, J and (1) A, B and (1) A (4) C, D, F (2) ACPL (2) Type A–L (3) C, D, F (2) Type A–L Hubs or and (1) A, B (2) G, H, I, J Provided per and (1) A, B, C compartment. (3) C, D, F Provided per compartment. (4) C, D, F 200 A 6-Position MP86200 MPH86200 MPR86200 225 A 2-Position MPL32225 (2) ACPL (2) Type A–L (2) Type A–L Hubs or (3) C, D, E, F and (2) E, F, G, H, I, J and (1) A, B (1) A, B (3) C, D, E, F 225 A 3-Position MPL53225 (2) ACPL (2) Type A–L (2) Type A–L Hubs or (4) C, D, E, F and (2) E, F, G, H, I, J and (1) A, B (1) A, B (4) C, D, E, F 225 A 4-Position MPL64225 (2) ACPL (2) Type A–L (2) Type A–L Hubs or (5) C, D, E, F and (2) E, F, G, H, I, J and (1) A, B (1) A, B (5) C, D, E, F 1 Same knockout pattern on side of box. 13 03/2008 © 2008 Schneider Electric All Rights Reserved MP Meter-Pak™ Meter Centers Application Data Main Lugs Section Service Conductor Termination Data • • Neutral bus is bonded permanently to the enclosure Suitable only for use as service equipment 125 A Maximum MP Meter-Pak™ Meter Center Service Conductor Termination Data Factory-Installed Line Phase and Number of Meter Main Bus Rating Main Lugs Capacity Neutral Lug Wire Size Socket Positions (Amperes) (Amperes) Al/Cu AWG kcmil 2 200 A 200 A 3 300 A 300 A (1) #4-250 4 400 A 400 A 5 500 A 400 A Al or 500 A Cu 6 600 A 400 A Al or 500 A Cu (1) 1/0-600 or (2) 1/0-250 200 A Maximum MP Meter-Pak Meter Center Service Conductor Termination Data Main Lugs Compartment 2 400 A 400 A 3 400 A 400 A 4 600 A 400 A Al or 500 A Cu 5 800 A 600 A Al or 750 A Cu 6 800 A 600 A Al or 750 A Cu (1) 1/0-600 or (2) 1/0-250 (2) 3/0-500 225 A Maximum MP Meter-Pak Meter Center Service Conductor Termination Data MMLK250 MMLK500 2 350 A 350 A 3 500 A 400 A 4 600 A 400 A (1) 1/0-600 or (2) 1/0-250 Alternate Lug Kits Available for use on 3–6 position 125 A, all 200 A, and all 225 A Meter-Pak meter center units (order separately): MMSK2 Catalog Number Lug Type (Mechanical) Lug Wire Size Al/Cu AWG/kcmil MMLK250 1 Double-Barrel (1) 1/0-600 or (2) 1/0-250 MMLK500 Double-Barrel (2) 3/0-500 MMLK600 2 Double-Barrel (2) #2-600 1 Standard lug kit supplied factory-installed on 3–6 position 125 A units, 2–4 position 200 A units, and 2–4 position 225 A units. 2 Kit includes NEMA/EUSERC lug landing pads (MMSK2). Kit is rated 800 A maximum (600 A maximum in EUSERC areas). NEMA/EUSERC Lug Landing Kit MMLK600 MMSK4 • • Catalog numbers MMSK2 and MMSK4 (order separately). • MMSK4 is available for use ONLY on MPL53225 and MPL64225, Not required for MPL32225. • Kits include three bus bar lug landing pads and mounting hardware to secure pads to main cross bus. • Each lug landing pad with MMSK2 is supplied with two 1/2-13 studs; MMSK4 with four 1/2-13 studs; all on 1-3/4 inch center. Kits include lug mounting hardware. • • MMSK2 is rated 600A maximum when applied in EUSERC areas. MMSK2 is available for use on 3- through 6-position 125 A and all 200 A Meter-Pak meter center units. Order one kit per Meter-Pak device, order lugs separately (refer to each device wiring diagram for lug catalog numbers). 14 © 2008 Schneider Electric All Rights Reserved 03/2008 MP Meter-Pak™ Meter Centers Application Data Lugs for Use with NEMA/EUSERC Lug Landing Kit MMSK2 Mains Rating Lug Manufacturer Anderson ILSCO 800 A 1 4/0–500 Al/Cu VC-6FT VCEL-060-12H2 400–600 Al, 400–500 Cu VC-6FT VCEL-075-12H2 500 Cu VC-6FT Compression 4/0–500 Cu VC-6FT VHCL-400-12BN 4/0–400 Cu VC-6FT VHCL-350-12BN 3/0–350 Cu VC-6FT TA-600-2N 2 #2-600 Al/Cu 375 lb-in. (42 N•m) (2) #2-600 Al/Cu 500 lb-in. (57 N•m) Mechanical VHCL-600-12BN Compression TA-600-2N 2 ILSCO 500–600 A VACL-500-12BN AU-600-2N Anderson 400 A Crimping Tool or Torque VHCL-500-12BN 300 A MMSK2 Lug Wire Size AWG/kcmil Catalog Number 1 Lug Type Mechanical AU-600-2N AU-600-2N ILSCO Mechanical AU-600-2N 250–600 Cu VC-6FT #2-600 Al/Cu 375 lb-in. (42 N•m) (2) #2-600 Al/Cu 500 lb-in. (57 N•m) (2) #2-600 Al/Cu 500 lb-in. (57 N•m) (2) 3/0-500 Al/Cu 500 lb-in. (57 N•m) Lugs are not available from Schneider Electric and must be ordered separately from Anderson or ILSCO. Available by ordering kit catalog number CMELK4 (kit includes 4 lugs). 2 Lugs for Use with NEMA Lug Landing Kit MMSK4 Catalog Number Lug Catalog Number 1 Lug Type Manufacturer L1D2-600 L1D2-800 MMSK4 Anderson MPL32225 ILSCO 2/0–500 Al/Cu VC-6FT VC-6FT VCEL-075-12H2 500–750 Al or 500 Cu VC-6FT VACL-500-12BN 4/0–500 Al/Cu VC-6FT 350–600 Al or 350–500 Cu VC-6FT or VC8 VC-6FT or VC8 Compression VACL-750-12BN 500–750 Al or 500 Cu VACL-1000-12BN 750–1000 Al VC8 VHCL-500-12BN 4/0–500 Cu VC-6FT or VC-7FT VHCL-600-12BN 3/0–350 Cu VC-6FT TA-600-2N 3 #2-600 Al/Cu 375 lb-in. (42 N•m) TA-800-2N Mechanical 500 lb-in. (57 N•m) 500 lb-in. (57 N•m) #2-600 Al/Cu 375 lb-in. (42 N•m) 2AB2-600 (2) #2-600 Al/Cu 375 lb-in. (42 N•m) (3) #6-250 Al/Cu 275 lb-in. (31 N•m) 300–800 Al/Cu 550 lb-in. (62 N•m) #2-600 Al/Cu 550 lb-in. (62 N•m) 3AB2-250 Mechanical Mechanical VCEL-050-12H2 2/0–500 Al/Cu VC-6FT VCEL-060-12H2 400–600 Al, 400–500 Cu VC-6FT VACL-500-12BN Compression VHCL-500-12BN VHCL-600-12BN 1) 300–800 Al/Cu (2) #2-600 Al/Cu A1B2-600-2 L1D2-600 MPL53225 550 lb-in. (62 N•m) 550 lb-in. (62 N•m) 400–600 Al or 400–500 Cu L1D2-800 Anderson #2-600 Al/Cu 300–800 Al/Cu VCEL-060-12H2 AU-600-2N Connector Manufacturing Company Crimping Tool or Torque VCEL-050-12H2 VACL-600-12BN 2 Mechanical Lug Wire Size AWG/kcmil ILSCO TA-600-2N 3 Connector Manufacturing Company A1B2-600-2 3AB2-250 Mechanical Mechanical 4/0–500 Al/Cu VC-6FT 4/0–500 Cu VC-6FT or VC-7FT 250–600 Cu VC-6FT, VC-7FT, or VC-8 #2-600 Al/Cu 375 lb-in. (42 N•m) #2-600 Al/Cu 375 lb-in. (42 N•m) (3) #6-250 Al/Cu 275 lb-in. (31 N•m) Lugs are not available from Schneider Electric and must be ordered separately from Anderson or ILSCO. 2) Lug landing kit is not required for this device. 3) Available by ordering kit catalog number CMELK4 (kit includes 4 lugs). Continued on next page 15 03/2008 © 2008 Schneider Electric All Rights Reserved MP Meter-Pak™ Meter Centers Application Data Lugs for Use with NEMA Lug Landing Kit MMSK4 Catalog Number Lug Catalog Number 1 Lug Type Manufacturer L1D2-600 Mechanical L1D2-800 Anderson MPL64225 ILSCO Crimping Tool or Torque #2-600 Al/Cu 550 lb-in. (62 N•m) 300–800 Al/Cu 550 lb-in. (62 N•m) 2/0–500 Al/Cu VC-6FT VCEL-060-12H2 400–600 Al or 400–500 Cu VC-6FT VCEL-075-12H2 500–750 Al or 500 Cu VC-6FT VACL-500-12BN 4/0–500 Al/Cu VC-6FT 350–600 Al or 350–500 Cu VC6-FT or VC8 Compression VACL-750-12BN 500–750 Al or 500 Cu VC6-FT or VC8 VHCL-500-12BN 4/0–500 Cu VC6-FT or VC7-FT VHCL-600-12BN 250–600 Cu VC6-FT, VC7-FT or VC8 TA-600-2N 3 #2-600 Al/Cu 375 lb-in. (42 N•m) TA-800-2N Mechanical AU-600-2N Connector Manufacturing Company Lug Wire Size AWG/kcmil VCEL-050-12H2 VACL-600-12BN MMSK4 Continued from previous page 300–800 Al/Cu 500 lb-in. (57 N•m) (2) #2-600 Al/Cu 500 lb-in. (57 N•m) A1B2-600-2 #2-600 Al/Cu 375 lb-in. (42 N•m) 2AB2-600 (2) #2-600 Al/Cu 375 lb-in. (42 N•m) 3AB2-250 Mechanical L1D2-800 (3) #6-250 Al/Cu 275 lb-in. (31 N•m) 300–800 Al/Cu 550 lb-in. (62 N•m) 1 Lugs are not available from Schneider Electric and must be ordered separately from Anderson or ILSCO. 2 Lug landing kit is not required for this device. 3 Available by ordering kit catalog number CMELK4 (kit includes 4 lugs). Tenant Circuit Breaker Termination Data 125 A Maximum MP Meter-Pak Meter Center Tenant Circuit Breaker Termination Data Tenant Circuit Breaker Type and Ampere Rating Lug Wire Size QO, QO-VH, and QOH 2-pole, 40–70 A #8–#2 AWG Al/Cu QO, QO-VH, and QOH 2-pole, 80–125 A #4–2/0 AWG Al/Cu 200 A Maximum MP Meter-Pak Meter Center Tenant Circuit Breaker Termination Data Tenant Circuit Breaker 1 Type and Ampere Rating Lug Wire Size Wire Bending Space QOM2-MM and QOM2-MVH 2-pole, 100–200 A #4 AWG–300 kcmil Al/Cu #4 AWG–250 kcmil Al/Cu 1 Bottom tenant circuit breaker position has wire bending space to accommodate 300 kcmil wire, for bottom feed only. 225 A Maximum MP Meter-Pak Meter Center Tenant Circuit Breaker Termination Data Tenant Circuit Breaker Type and Ampere Rating Lug Wire Size Wire Bending Space QBP-TM, QDP-TM, QGP-TM, and QJP-TM, 2-pole, 70–225 A #4 AWG–300 kcmil Al/Cu #4 AWG–300 kcmil Al/Cu 16 © 2008 Schneider Electric All Rights Reserved 03/2008 MP Meter-Pak™ Meter Centers Application Data Service Grounding/Load Neutral and Equipment Grounding Termination Data • Service grounding/load neutral lugs, located in the tenant compartment, are bonded to the enclosure. • • Two service grounding lugs provided per device. One load neutral lug and one equipment grounding lug are provided for each tenant circuit breaker position. 125 A Maximum MP, MPH, and MPR Meter-Pak Meter Centers Load neutral and service grounding lugs will accept one #14-2/0 AWG Cu or one #12-2/0 AWG Al conductor. Equipment Grounding Lugs 200 A Maximum MP, MPH, and MPR Meter-Pak Meter Centers Service Grounds and Load Neutrals Load neutral and service grounding lugs will accept one #6 AWG–300 kcmil Al/Cu conductor. 225 A Maximum MP, MPH, and MPR Meter-Pak Meter Centers Load neutral and service grounding lugs will accept one #4 AWG–300 kcmil Al/Cu conductor. Hinged Rain Channel Rain channel is hinged at bottom of tenant compartment allowing easy access to wiring gutter for pulling wires. Underground Service Wireway Square D brand Underground Service Wireways are a convenient solution for protecting a utility's underground service conductors that terminate in MP Meter-Pak Meter Centers. Hinged Rain Channel MP43X11PED Shown with Cover Off (left) and On (above) These Underground Service Wireways are not load-bearing; they are intended for use only as a means to cover and secure service entrance cables prior to entering a wall-mounted Square D MP Meter-Pak device. The units connect easily to any MP Meter-Pak Meter Center by attaching to tapped hub provisions in the bottom endwall of the metering device. • • Cover latch accommodates up to three different types of utility seals. • Mounts easily to MP Meter-Pak device’s underground, bolt-on hub provisions using supplied hardware. • Open bottom with ½ inch srolled edge reduces possibility of cutting conductor insulation. • • Wireway covers are secured by latching means (no screws to lose). • Constructed of 14-gauge painted galvanneal steel for superior corrosion protection in all applications. All locking provisions are made of durable, corrosion-resistant stainless steel for long-lasting security. Gasketed, bushed openings in top provide watertight seal between the wireway and MP Meter-Pak device. 17 03/2008 © 2008 Schneider Electric All Rights Reserved MP Meter-Pak™ Meter Centers Application Data Underground Service Wireway Devices Height Catalog Number Width Description in. mm in. mm 279 MP43X11PED Underground Service Wireway 43 1092 11 MP43X8PED Underground Service Wireway 43 1092 8 203 MP35X11PED Underground Service Wireway 35 889 11 279 MP12X11PEDEXT Underground Service Wireway One-foot Extension 12 305 11 279 MP12X8PEDEXT Underground Service Wireway One-foot Extension 12 305 8 203 Selection Chart Grade to Meter Wireway Catalog Number Grade to Device Bottom Bottom Meter Top Meter in. mm in. mm 42.5 1080 51.5 1308 MP Meter-Pak Device MP22125 MP43X8PED 25 in. [635 mm] MPR22125 MPH22125 MP33125 54.0 1372 MPH33125 MP44125 63.0 36.0 1600 Top Meter Height MPR33125 MPR44125 MP Meter-Pak Unit Bottom of Device MPH44125 914 MP55125 MPR55125 54.0 1372 MPH55125 Bottom Meter Height Wireway Unit Grade MP66125 MPR66125 18 in. MPH66125 MP42200 MP43X11PED 25 in. [635 mm] 46.25 1175 MPR42200 MPH42200 MP43200 55.25 1403 MPR43200 Wireway Extension 12 in. Measurement Guide MPH43200 MP64200 37.25 946 64.25 1632 MPR64200 MPH64200 MP85200 MPR85200 55.25 1403 MPH85200 MP86200 Underground Service Wireway One-Foot Extension Selection Guide* For applications requiring additional depth, or for sloped grades, the one-foot extension can be installed to the bottom of the underground service wireway with supplied hardware. MPR86200 MPH86200 16.625 in. 50.625 MP35X11PED [422 mm] 1286 64.625 1642 MPL32225 MP43X11PED 25 in. [635 mm] 38.375 975 66.375 1686 MPL43225 MP35X11PED 16.625 in. [422 mm] 30.0 762 72.0 1829 MPL64225 Wireway Extension Catalog Number Wireway Catalog Number MP12X11PEDEXT MP43X11PED MP35X11PED MP12X8PEDEXT MP43X8PED *Selection based on Underground Service Wireway catalog numbers. 18 © 2008 Schneider Electric All Rights Reserved 03/2008 MP Meter-Pak™ Meter Centers Catalog Number Description Catalog Number Description Number Segment Device Name Socket/Bypass Type Character Description MP MP Meter-Pak Meter Center Blank Ring Type R Ringless with 5th Jaw H Ringless with Horn Bypass and 5th Jaw L Ringless with Lever Bypass, Jaw Release and 5th Jaw 2 200 A 3 300 A 4 400 A 5 500 A 6 600 A 8 800 A 2 2-Positions MP, MPH, MPL, and MPR 3 3-Positions MP, MPH, MPL, and MPR 4 4-Positions MP, MPH, MPL, and MPR 5 5-Positions MP, MPH, and MPR 6 6-Positions MP, MPH, MPL, and MPR 125 125 A 200 200 A 225 225 A H 4 4 125 Bus Ampacity Number of Meter Sockets Max. Tenant Circuit Breaker Amperage 19 03/2008 © 2008 Schneider Electric All Rights Reserved MP Meter-Pak™ Meter Centers Select MP Meter-Pak meter center short circuit current rating RMS symmetrical amperes from table on page 3, then make selections from the following: Step 1: Select Ring or Ringless Type MP Meter-Pak™ Meter Centers Metering Equipment Number of Positions Ampere Rating 125 A (Use QO® Circuit Breakers) 200 A (Use QOM2 Circuit Breakers) 225 A (Use QB, QD, QG or QJ Circuit Breakers) 1 Ringless Type, 5-Jaw Ring-Type, 4-Jaw Catalog Number No Bypass Catalog Number Horn Bypass Catalog Number Lever Bypass Catalog Number 2 MP22125 MPR22125 MPH22125 — 3 MP33125 1 MPR33125 MPH33125 — 4 MP44125 1 MPR44125 MPH44125 — 5 MP55125 1 MPR55125 MPH55125 — 6 MP66125 1 MPR66125 MPH66125 — 2 MP42200 1 MPR42200 MPH42200 — 3 MP43200 1 MPR43200 MPH43200 — 4 MP64200 1 MPR64200 MPH64200 — 5 MP85200 1 MPR85200 MPH85200 — 6 MP86200 1 MPR86200 MPH86200 — 2 — — — MPL32225 3 — — — MPL53225 4 — — — MPL64225 Meets EUSERC standards with addition of lug landing kit, MMSK2. Step 2: Select Tenant Circuit Breakers Device Type 125 A 200 A 225 A Ampere Rating 10,000 AIR 120/240 Vac 22,000 AIR 120/240 Vac 25,000 AIR 120/240 Vac 42,000 AIR 120/240 Vac 65,000 AIR 120/240 Vac 100,000 AIR 120/240 Vac 40 QO240 QO240VH — QOH240 — — 50 QO250 QO250VH — QOH250 — — 60 QO260 QO260VH — QOH260 — — 70 QO270 QO270VH — QOH270 — — 80 QO280 QO280VH — QOH280 — — 90 QO290 QO290VH — QOH290 — — 100 QO2100 QO2100VH — QOH2100 — — 125 QO2125 QO2125VH — QOH2125 — — 100 QOM2100MM QOM2100MVH — — — — 125 QOM2125MM QOM2125MVH — — — — 150 QOM2150MM QOM2150MVH — — — — 175 QOM2175MM QOM2175MVH — — — — 200 QOM2200MM QOM2200MVH — — — — 40 QO240 2 QO240VH 2 — QOH240 2 — — 50 QO250 2 QO250VH 2 — QOH250 3 — — 60 2 2 — QOH260 3 — — QO260 QO260VH 70 QBP22070TM — QDP22070TM — QGP22070TM QJP22070TM 80 QBP22080TM — QDP22080TM — QGP22080TM QJP22080TM 90 QBP22090TM — QDP22090TM — QGP22090TM QJP22090TM 100 QBP22100TM — QDP22100TM — QGP22100TM QJP22100TM 110 QBP22110TM — QDP22110TM — QGP22110TM QJP22110TM 125 QBP22125TM — QDP22125TM — QGP22125TM QJP22125TM 150 QBP22150TM — QDP22150TM — QGP22150TM QJP22150TM 175 QBP22175TM — QDP22175TM — QGP22175TM QJP22175TM 200 QBP22200TM — QDP22200TM — QGP22200TM QJP22200TM 225 QBP22225TM — QDP22225TM — QGP22225TM QJP22225TM 2 Requires use of EZM125QOA adapter (order separately). 3 Order only. Not stocked in PDS. 20 © 2008 Schneider Electric All Rights Reserved 03/2008 MP Meter-Pak™ Meter Centers Product Selection Step 3: Choose Accessories Accessories—Description and / or Replacement Parts Catalog Number 5th Jaw Kit (one per kit) 5J Barrel Lock Head Protector Kit (use on MPH, MPL and MPR only; barrel lock not included) MMBLC QO Adapter for Bolt-on QB, QD, QG and QJ Tenant Circuit Breakers (40–125 A, 2-pole) EZM125QOA Horn Bypass Kit (use on MPR and MPH only) MMHB Manual Slider Type Bypass: 125 A Ring Type 2-Position Top Meter (only) MM125MB 1 125 A and 200 A Ring Type MM200MB 1 Sealing Rings: Snap-type Aluminum (standard) 29209-100-01 Screw-type Aluminum 29008W Snap-type Stainless Steel ARP00026 LEXAN® Meter Socket Closing Plate 29007 Optional Lug Kits (3 Lugs per kit): (1) 1/0-600 AWG/kcmil or (2) 1/0-250 per phase Al/Cu MMLK250 2 3 (2) 3/0-500 AWG/kcmil per phase Al/Cu MMLK500 3 (2) 2-600 AWG/kcmil per phase Al/Cu MMLK600 3 Semi-flush Kits: 125 A, 2-Position MPSF12 125 A, 3- and 4-Position MPSF14 125 A, 5- and 6-Position MPSF16 200 A, 2- and 3-Position MPSF23 200 A, 4-Position MPSF24 200 A, 5- and 6-Position MPSF26 NEMA/EUSERC Lug Landing Kit: For 3- through 6-position 125 A and all 200 A devices. Each pad rated 600 A maximum and includes (2) 1/2-13 studs and mounting hardware. MMSK2 3 NEMA Lug Landing Kit: For use ONLY on MPL32225, MPL53225 and MPL64225 with optional lugs (see Table on page 16 for lugs) MMSK4 1 The meter center short circuit current rating is 10,000 RMS symmetrical amperes when manual slider-type bypass is used. Not rated for continuous duty. 2 Standard lug for 3- through 6-position 125 A and 2- through 4-position 200 A devices. 3 Cannot be installed on 2-position 125 A devices. 21 03/2008 © 2008 Schneider Electric All Rights Reserved MP Meter-Pak™ Meter Centers Dimensions Supplied with ACP Closing Plate (for Underground Service). Order Type A Hub Separately (for Overhead Service). 1.97 [50] 3.67 [93] 7.10 [180] 0.19 [5] 12.28 [312] 9.37 [238] 1.38 [35] 2.56 [65] Embossed Mounting Holes (4 Locations) 0.25 Dia. [6] From Top to Center of Embossed Mounting Holes 2.56 [65] 0.42 Dia. [11] 0.09 Dia. [2] 37.50 [953] 24.31 [617] 0.09 0.33 Slot [2] x [8] 24.31 [617] 9.00 [229] Ringless Cover Latch Line Phase Lugs 18.50 C, D, F [470] 11.25 [286] C, D, F 8.62 [219] 6.97 [177] 3.77 [96] 4.70 [119] 2.32 [60] Line Neutral Lug 6.97 [177] 1.75 [44] 3.77 [96] 0.10 0.40 Slot 0.10 Dia. x [3] [10] [3] 0.42 Dia. [11] Seal Bracket 12.13 [308] 1.79 [45] C, D, F 1.75 [44] 4.70 [119] 3.08 [78] A or B300 Hub Provision D, F, G A 0.95 [24] 0.38 Dia. [10] 1.73 [44] 0.83 [21] 8.14 [207] 2.09 [53] Mounting Feet MP22125 MPR22125 MPH22125 Dimensions: Knockouts Conduit Size Hole Diameter Symbol in. mm in. mm A 0.50 13 0.88 22 B 0.75 19 1.25 32 C 1.00 25 1.38 35 D 1.25 32 1.75 44 E 1.50 38 2.00 51 F 2.00 51 2.50 64 G 2.50 64 3.00 76 H 3.00 76 3.63 92 I 3.50 89 4.13 105 J 4.00 102 4.63 118 22 © 2008 Schneider Electric All Rights Reserved 03/2008 in. [mm] MP Meter-Pak™ Meter Centers Product Selection Supplied with ACPL Closing Plate (for Underground Service). Order Type A–L Hub Separately (for Overhead Service). 6.07 [154] 2.76 [70] 24.34 [618] 4.87 [124] 7.28 [185] (NTS) 12.00 [305] Top Position Omitted on 3-Position Unit 0.09 Dia. [2] Line Phase Lugs 3.44 [87] Typical Cover Lifting Handles 48.12 [1222] 0.75 [19] 5.58 [142] 13.50 [343] 6.85 [174] 10.05 [255] 1.75 [44] 47.37 [1203] 0.95 [24] 24.19 [614] A–L Hub Provision E, F, G, H, I, J A–L Hub Provision E, F, G, H A, B 3.20 [81] 1.78 [45] 0.10 0.40 Slot 0.10 Dia. x [10] [3] [3] 0.42 Dia. [11] Seal Bracket 6.53 [166] 5.25 [133] C, D, F A, B 1.80 [46] 4.75 [121] 0.09 0.33 Slot [2] x [8] Ringless Cover Latch 9.00 [229] Typical 23.62 2.84 [600] [72] 11.19 [284] C, D, F 2.29 [58] 0.42 Dia. [11] 9.00 [229] 1.73 [44] 0.38 Dia. [10] Mounting Feet 3.00 [76] MP33125 MP44125 MPR33125 MPR44125 MPH33125 MPH44125 Dimensions: Knockouts Conduit Size Hole Diameter Symbol in. mm in. mm A 0.50 13 0.88 22 B 0.75 19 1.25 32 C 1.00 25 1.38 35 D 1.25 32 1.75 44 E 1.50 38 2.00 51 F 2.00 51 2.50 64 G 2.50 64 3.00 76 H 3.00 76 3.63 92 I 3.50 89 4.13 105 J 4.00 102 4.63 118 23 03/2008 © 2008 Schneider Electric All Rights Reserved in. [mm] MP Meter-Pak™ Meter Centers Product Selection Supplied with ACPL Closing Plate (for Underground Service). Order Type A Hub Separately (for Overhead Service). 15.23 [387] 6.00 [152] 2.76 [70] 39.46 [926] 12.00 [305] 4.70 [119] 7.28 [185] (NTS) 7.36 [187] Line Phase Lugs Top Position Omitted on 5-Position Unit 0.75 [19] N 3.44 [87] Typical C, D, F 5.85 [149] 7.75 [197] 9.05 [230] A, B 2.61 [66] 6.22 [158] 20.75 [527] 3.20 [81] 18.02 [458] A 0.09 Dia. [2] 0.09 0.33 Slot [2] x [8] Ringless Cover Latch 6.53 [166] 0.10 Dia. [3] 0.42 Dia. [11] A-L Hub Provision G, H, I, J 15.07 [383] 3.00 [76] 2.99 [76] 3.20 [81] 0.10 0.40 Slot x [3] [10] Seal Bracket 0.95 1.73 [24] [44] 0.38 Dia. [10] Mounting Feet MP55125 MPR55125 MPH55125 MP66125 MPR66125 MPH66125 Knockouts Conduit Size 3.02 [77] 9.42 [239] 36.31 [922] 14.92 [379] C, D, F 1.75 [44] 41.62 [1057] 9.00 [229] Typical 23.62 [600] 11.19 [284] Cover Lifting Handles 2.95 [75] 2.65 [67] 0.42 Dia. [11] 42.37 [1076] Dimensions: Hole Diameter Symbol in. mm in. mm A 0.50 13 0.88 22 B 0.75 19 1.25 32 C 1.00 25 1.38 35 D 1.25 32 1.75 44 E 1.50 38 2.00 51 F 2.00 51 2.50 64 G 2.50 64 3.00 76 H 3.00 76 3.63 92 I 3.50 89 4.13 105 J 4.00 102 4.63 118 24 © 2008 Schneider Electric All Rights Reserved 03/2008 in. [mm] MP Meter-Pak™ Meter Centers Product Selection Supplied with ACPL Closing Plate (for Underground Service). Order Type A Hub Separately (for Overhead Service). 9.70 [246] 3.70 [94] 2.58 [66] 29.44 [748] Top Position Omitted on 2-Position Unit 0.42 Dia. [11] 8.28 [210] (NTS) 7.25 [184] 0.09 Dia. [2] Line Phase Lugs Ringless Cover Latch 43.41 [1103] Line Neutral Lugs C, D, F 2.25 [57] 2.70 [69] C, D, F 12.15 [309] 42.66 [1084] 31.50 9.00 [800] [229] 28.00 Typical [711] 24.62 [625] 12.22 [310] 8.38 [213] 12.55 [319] 6.10 [155] 0.09 0.33 Slot [2] x [8] 0.75 [19] 7.53 [191] 0.10 Dia. [3] 0.42 Dia. [11] 0.10 0.40 Slot x [3] [10] Seal Bracket 29.31 [744] A, B 10.41 [264] 1.94 [49] A-L Hub Provision G, H, I, J 0.38 Dia. [10] 0.95 1.73 [24] [44] Mounting Feet 2.66 [68] 3.33 [85] (Typ.) 3.00 [76] 3.04 [77] 9.20 [234] 15.48 [393] MP42200 MPR42200 MPH42200 MP43200 MPR43200 MPH43200 in. Dimensions: [mm] Knockouts Conduit Size Hole Diameter Symbol in. mm in. mm A 0.50 13 0.88 22 B 0.75 19 1.25 32 C 1.00 25 1.38 35 D 1.25 32 1.75 44 E 1.50 38 2.00 51 F 2.00 51 2.50 64 G 2.50 64 3.00 76 H 3.00 76 3.63 92 I 3.50 89 4.13 105 J 4.00 102 4.63 118 25 03/2008 © 2008 Schneider Electric All Rights Reserved MP Meter-Pak™ Meter Centers Product Selection Supplied with ACPL Closing Plate (for Underground Service). Order Type A-L Hub Separately (for Overhead Service). 9.70 [246] 3.70 [94] 2.58 [66] 9.82 [249] 29.44 [748] 0.42 Dia. [11] 8.25 [210] (NTS) 7.36 [187] 0.09 Dia. [2] 0.75 [19] Line Phase Lugs 0.09 0.33 Slot [2] x [8] Ringless Cover Latch 52.00 [1321] 51.25 [1302] Line Neutral Lugs C, D, F 2.23 [57] 5.65 [144] 2.45 [62] C, D, F 1.94 [49] 2.66 [68] 5.85 [149] 12.15 [309] 12.55 [319] 31.50 [800] 9.00 [229] 28.00 [711] Typ. 24.62 [625] 12.22 [310] 7.53 [191] 0.10 Dia. [3] 0.42 Dia. [11] 0.10 0.40 Slot x [3] [10] Seal Bracket 8.38 [213] 0.95 [24] 29.31 [744] 10.37 [263] A, B 3.00 [76] 9.20 [234] 3.33 [85] (Typ.) 15.48 [393] A-L Hub Provision G, H, I, J 1.73 [44] 3.04 [77] 0.38 Dia. [10] Mounting Feet MP64200 MPR64200 MPH64200 Knockouts Conduit Size in. Dimensions: [mm] Hole Diameter Symbol in. mm in. mm A 0.50 13 0.88 22 B 0.75 19 1.25 32 C 1.00 25 1.38 35 D 1.25 32 1.75 44 E 1.50 38 2.00 51 F 2.00 51 2.50 64 G 2.50 64 3.00 76 H 3.00 76 3.63 92 I 3.50 89 4.13 105 J 4.00 102 4.63 118 26 © 2008 Schneider Electric All Rights Reserved 03/2008 MP Meter-Pak™ Meter Centers Product Selection Supplied with ACPL Closing Plate (for Underground Service). Order Type A-L Hub Separately (for Overhead Service). 9.82 [249] Top Left Position Omitted on 5-Position Unit 7.36 [187] 26.34 [669]20.34 [517] 0.42 Dia. [11] 2.58 [66] 46.68 [1186] 12.00 [305] 8.28 [210] (NTS) 9.82 [249] Line Phase Lugs 0.75 [19] 43.41 [1321] 31.50 9.00 [800] [229] 28.25 Typ. [718] 24.50 [622] 12.22 [310] Line Neutral Lugs C, D, F 2.23 [57] 6.35 [161] 8.60 [218] 12.15 [309] 2.95 [75] Seal Bracket 0.95 [24] A-L Hub Provision G, H, I, J 3.04 A, B, C 0.10 0.40 Slot x [3] [10] 0.10 Dia. [3] 0.42 Dia. [11] 14.20 [361] 46.56 [1183] 1.93 [49] 0.09 0.33 Slot [2] x [8] Ringless Cover Latch 42.66 [1084] 7.53 [191] 5.00 [127] 10.81 [275] 29.25 [743] C, D, F 0.09 Dia. [2] 0.38 Dia. [10] 1.73 [44] [77] Mounting Feet 2.66 [68] 20.12 [511] 6.20 [68] 3.33 [85] (Typ.) MP85200 MPR85200 MPH85200 4.53 [115] MP86200 MPR86200 MPH86200 in. Dimensions: [mm] Knockouts Conduit Size Hole Diameter Symbol in. mm in. mm A 0.50 13 0.88 22 B 0.75 19 1.25 32 C 1.00 25 1.38 35 D 1.25 32 1.75 44 E 1.50 38 2.00 51 F 2.00 51 2.50 64 G 2.50 64 3.00 76 H 3.00 76 3.63 92 I 3.50 89 4.13 105 J 4.00 102 4.63 118 27 03/2008 © 2008 Schneider Electric All Rights Reserved MP Meter-Pak™ Meter Centers Product Selection Supplied with ACPL Closing Plate (for Underground Service). Order Type A-L Hub Separately (for Overhead Service). 9.62 [244] (NTS) 8.36 [212] 2.62 [67] 1.50 [38] 2.81 [71] 19.43 [494] Tenant Circuit Breaker Doors (Lockable) 60.25 [1530] Cover Knockout for use with Utility Barrel Lock 0.75 [19] To Top of Mounting Channel Mounting Channel Detail 1.75 [44] 14.00 [356] Individual Meter Socket Covers; Ringless Style (Supplied with Cover Sealing Latches) 5.72 [145] 21.87 [556] 7.10 [180] C, D, E, F 4.50 [114] Line Phase Lugs Line Neutral Lugs 4.43 [113] 10.47 [266] 2.20 [56] 4.12 [105] 1.89 [48] Lug Detail 26.76 [680] 3.25 [83] 5.34 [138] (2) 1/2–13 Studs 1.75 [44] 34.00 [864] C, D, E, F 0.34 [9] A, B 0.09 Dia. [2] 0.09 0.33 Slot [2] x [8] Ringless Cover Latch 3.00 [76] 8.87 [225] 1.87 [48] 5.37 [136] 0.42 Dia. [11] 2.68 [68] 5.93 [151] A-L Hub Provision E, F, G, H, I, J 0.13 Dia. [3] 0.44 Dia. [11] 0.10 0.50 Slot x [3] [13] Seal Bracket 9.00 [229] MPL32225 0.95 1.73 [24] [44] 0.38 Dia. [10] Mounting Foot Knockouts Conduit Size Hole Diameter Symbol in. mm in. mm A 0.50 13 0.88 22 B 0.75 19 1.25 32 C 1.00 25 1.38 35 D 1.25 32 1.75 44 E 1.50 38 2.00 51 F 2.00 51 2.50 64 G 2.50 64 3.00 76 H 3.00 76 3.63 92 I 3.50 89 4.13 105 J 4.00 102 4.63 118 in. Dimensions: [mm] 28 © 2008 Schneider Electric All Rights Reserved 03/2008 MP Meter-Pak™ Meter Centers Product Selection Supplied with ACPL Closing Plate (for Underground Service). Order Type A-L Hub Separately (for Overhead Service). 11.30 [287] 9.68 [246] 2.75 [70] 0.34 [9] 4.80 [122] 35.37 [898] 10.87 [276] Tenant Circuit Breaker Doors (Lockable) 1.50 [38] Line Phase Lugs Cover Knockout for use with Utility Barrel Lock Line Neutral Lugs Individual Meter Socket Covers: Ringless Style (Supplied with Cover Sealing Latches} 14.00 [356] 6.32 [161] 24.10 [612] 17.62 [448] 13.32 [338] 2.53 [84] 10.10 [257] 13.90 [353] 26.40 [671] A-L Hub Provision E, F, G, H, I, J 0.09 Dia. [2] 0.09 0.33 Slot [2] x [8] Ringless Cover Latch 0.10 0.50 Slot x [3] [13] Seal Bracket 3.11 [79] A, B 2.07 [53] 5.86 [149] 0.42 Dia. [11] 0.13 Dia. [3] 0.44 Dia. [11] 35.25 [895] 2.11 [54] To Top of Mounting Channel Mounting Channel Detail 4.50 [114] C, D, E, F 6.00 [152] 53.12 [1349] 28.10 [714] C, D, E, F 3.20 [81] 0.75 [19] 0.95 [24] 10.25 [260] 9.65 [245] 13.44 [341] 2.84 [72] 4.05 [103] 0.38 Dia. [10] 1.73 [44] Mounting Foot MPL53225 Knockouts Conduit Size Dimensions: in. [mm] Hole Diameter Symbol in. mm in. mm A 0.50 13 0.88 22 B 0.75 19 1.25 32 C 1.00 25 1.38 35 D 1.25 32 1.75 44 E 1.50 38 2.00 51 F 2.00 51 2.50 64 G 2.50 64 3.00 76 H 3.00 76 3.63 92 I 3.50 89 4.13 105 J 4.00 102 4.63 118 29 03/2008 © 2008 Schneider Electric All Rights Reserved MP Meter-Pak™ Meter Centers Product Selection Supplied with ACPL Closing Plate (for Underground Service). Order Type A-L Hub Separately (for Overhead Service) 11.30 [287] 2.75 [70] 9.68 [246] (NTS) 4.80 [122] 0.34 [9] 35.37 [898] Line Phase Lugs Line Neutral Lugs Tenant Circuit Breaker Doors (Lockable) Cover Knockout for use with Utility Barrel Lock 1.50 [38] 41.87 [1064] 7.00 [178] 14.00 [356] 2.53 [64] 3.20 [81] 6.32 [161] 38.50 [978] 31.62 [803] 13.32 [338] 0.42 Dia. [11] 0.09 Dia. [2] 0.09 0.33 Slot [2] x [8] Ringless Cover Latch 0.13 Dia. [3] 10.10 [257] C, D, E, F 6.00 [152] To Top of Mounting Channel Mounting Channel Detail Individual Meter Socket Covers; Ringless Style (Supplied with Cover Sealing Latches) C, D, E, F 0.75 [19] 67.37 [1711] 26.40 [671] 4.50 [114] 13.90 [353] A–L Hub Provision E, F, G, H, I, J 35.25 [895] A, B 2.11 [54] 3.11 [79] 0.44 Dia. [11] Seal Bracket 0.95 [24] 2.07 [53] 5.86 9.65 [149] [245] 13.44 [341] 2.84 [72] MPL64225 0.38 Dia. [10] 1.73 [44] Mounting Foot Dimensions: Knockouts Conduit Size 10.25 [260] 4.05 [103] 0.10 0.50 Slot x [3] [13] in. [mm] Hole Diameter Symbol in. mm in. mm A 0.50 13 0.88 22 B 0.75 19 1.25 32 C 1.00 25 1.38 35 D 1.25 32 1.75 44 E 1.50 38 2.00 51 F 2.00 51 2.50 64 G 2.50 64 3.00 76 H 3.00 76 3.63 92 I 3.50 89 4.13 105 J 4.00 102 4.63 118 30 © 2008 Schneider Electric All Rights Reserved 03/2008 MP Meter-Pak™ Meter Centers Product Selection 125 A Devices Omitted on 3-Position Unit Fifth Jaw Factory Installed on Ringless Device Omitted on 5-Position Unit ø ø ø øø ø ø øø ø ø N Line øø ø ø ø ø ø N ø Neutral, Service Ground and Equipment Grounding Terminals ø Line Fifth Jaw Factory Installed on Ringless Device N MP22125 MPR22125 MPH22125 øø Fifth Jaw Factory Installed on Ringless Device øø øø Equipment Grounding Terminals øø Neutral and Service Ground Equipment Grounding Terminals Neutral and Service Ground MP33125 MPR33125 MPH33125 MP66125 MPR66125 MPH66125 MP55125 MPR55125 MPH55125 MP44125 MPR44125 MPH44125 Omitted on 5-Position Unit 200 A Devices ø Omitted on 2-Position Unit ø ø ø ø ø ø ø ø ø ø N Line ø ø N ø ø ø ø ø Line ø ø ø ø Fifth Jaw Factory Installed N on Ringless Device Line Fifth Jaw Factory Installed on Ringless Device ø ø ø ø ø ø Fifth Jaw Factory Installed on Ringless Device ø ø Equipment Grounding Terminals Neutral and Service Ground MP42200 MPR42200 MPH42200 MP43200 MPR43200 MPH43200 Equipment Grounding Terminals ø ø Neutral and Service Ground MP85200 MPR85200 MPH85200 Equipment Grounding Terminals Neutral and Service Ground MP64200 MPR64200 MPH64200 MP86200 MPR86200 MPH86200 øø 225 A Devices øø øø øø Line ø ø øø øø Line ø ø øø ø ø Line Neutral and Service Grounding Terminals Equipment Grounding Terminals MPL32225 øø Equipment Grounding Terminals Neutral and Service Grounding Terminals MPL53225 øø Equipment Grounding Terminals Neutral and Service Grounding Terminals MPL64225 31 03/2008 © 2008 Schneider Electric All Rights Reserved Schneider Electric USA Schneider Electric Canada 1601 Mercer Road Lexington, KY 40511 USA 1-888-SquareD (1-888-778-2733) www.us.SquareD.com 19 Waterman Avenue, M4B 1 Y2 Toronto, Ontario 1-800-565-6699 www.schneider-electric.ca Square D, [D], Meter-Pak, and QO are trademarks or registered trademarks of Schneider Electric and/or its affiliates in the United States and/or other countries. Other marks used herein may be the property of their respective owners. 4141CT0701 © 2008 Schneider Electric All Rights Reserved 03/2008
© Copyright 2026 Paperzz