Manufacturer: Dimplex Model: LA 12TU Air Low-temperature heat pump: no Equipped with a supplementary heater: Heat pump combination heater: no Application: low Climate: colder Item Rated heat output * no Symbol Value Unit Prated 4,60 kW Item Seasonal space heating energy efficiency Symbol Value Unit ƞS 140 % Declared coefficient of performance or primary energy ratio for part load at indoor temperature 20 °C and outdoor temperature Tj Declared capacity for heating for part load at indoor temperature 20 °C and outdoor temperature Tj Tj = - 7 ºC Pdh 7,66 kW Tj = - 7 ºC COPd 3,17 Tj = + 2 ºC Pdh 9,54 kW Tj = + 2 ºC COPd 4,03 Tj = + 7 ºC Pdh 12,02 kW Tj = + 7 ºC COPd 5,20 Tj = + 12 ºC Pdh 13,74 kW Tj = + 12 ºC COPd 5,54 Tj = bivalent temperature Pdh 4,60 kW Tj = bivalent temperature COPd 1,81 Tj = operation limit Pdh 4,60 kW Tj = operation limit COPd 1,81 For air-to-water heat pumps: Tj = - 15 ºC (if TOL < - 20 ºC) Pdh 6,03 kW COPd 2,47 Bivalent temperature Tbiv -22 °C TOL -25 °C 10 W WTOL 58 °C Psup 0,00 kW Power input "compressor off" Power consumption in modes other than active mode POFF Off mode 5 W Thermostat-off mode PTO 24 W Standby mode PSB 11 W Crankcase heater mode PCK 0 W Other items Capacity control Sound power level, indoors/outdoors LWA Annual energy consumption QHE Contact details: fixed 61 2465 dB kWh For air-to-water heat pumps: Tj = - 15 ºC (if TOL < - 20 ºC) For air-to-water heat pumps: Operation limit temperature Heating water operating limit temperature Supplementary heater Rated heat output * Type of energy input electricity For air-to-water heat pumps: Rated air flow rate, outdoors - For water-/brine-to-water heat pumps: Rated brine or water flow rate, outdoor heat exchanger - 4100 Dimplex, * For heat pump space heaters and heat pump combination heaters, the rated heat output Prated is equal to the design load for heating Pdesignh, and the rated heat output of a supplementary heater Psup is equal to the supplementary capacity for heating sup(Tj). The calculation tool was made by Bundesverband Wärmepumpe BWP e.V. m3/h l/h Manufacturer: Dimplex Model: LA 12TU Air Low-temperature heat pump: no Equipped with a supplementary heater: Heat pump combination heater: no Application: medium Climate: colder Item Rated heat output * no Symbol Value Unit Prated 4,45 kW Item Seasonal space heating energy efficiency Symbol Value Unit ƞS 103 % Declared coefficient of performance or primary energy ratio for part load at indoor temperature 20 °C and outdoor temperature Tj Declared capacity for heating for part load at indoor temperature 20 °C and outdoor temperature Tj Tj = - 7 ºC Pdh 7,36 kW Tj = - 7 ºC COPd 2,23 Tj = + 2 ºC Pdh 9,23 kW Tj = + 2 ºC COPd 3,08 Tj = + 7 ºC Pdh 11,43 kW Tj = + 7 ºC COPd 4,08 Tj = + 12 ºC Pdh 13,35 kW Tj = + 12 ºC COPd 4,73 Tj = bivalent temperature Pdh 4,45 kW Tj = bivalent temperature COPd 1,16 Tj = operation limit Pdh 4,45 kW Tj = operation limit COPd 1,16 For air-to-water heat pumps: Tj = - 15 ºC (if TOL < - 20 ºC) Pdh 5,79 kW COPd 1,65 Bivalent temperature Tbiv -22 °C TOL -25 °C 10 W WTOL 58 °C Psup 0,00 kW Power input "compressor off" Power consumption in modes other than active mode POFF Off mode 5 W Thermostat-off mode PTO 24 W Standby mode PSB 11 W Crankcase heater mode PCK 0 W Other items Capacity control Sound power level, indoors/outdoors LWA Annual energy consumption QHE Contact details: fixed 61 2465 dB kWh For air-to-water heat pumps: Tj = - 15 ºC (if TOL < - 20 ºC) For air-to-water heat pumps: Operation limit temperature Heating water operating limit temperature Supplementary heater Rated heat output * Type of energy input electricity For air-to-water heat pumps: Rated air flow rate, outdoors - For water-/brine-to-water heat pumps: Rated brine or water flow rate, outdoor heat exchanger - 4100 Dimplex, * For heat pump space heaters and heat pump combination heaters, the rated heat output Prated is equal to the design load for heating Pdesignh, and the rated heat output of a supplementary heater Psup is equal to the supplementary capacity for heating sup(Tj). The calculation tool was made by Bundesverband Wärmepumpe BWP e.V. m3/h l/h Manufacturer: Dimplex Model: LA 12TU Air Low-temperature heat pump: no Equipped with a supplementary heater: Heat pump combination heater: no Application: low Climate: average Item Rated heat output * no Symbol Value Unit Prated 7,00 kW Item Seasonal space heating energy efficiency Symbol Value Unit ƞS 159 % Declared coefficient of performance or primary energy ratio for part load at indoor temperature 20 °C and outdoor temperature Tj Declared capacity for heating for part load at indoor temperature 20 °C and outdoor temperature Tj Tj = - 7 ºC Pdh 7,61 kW Tj = - 7 ºC COPd 2,97 Tj = + 2 ºC Pdh 9,48 kW Tj = + 2 ºC COPd 3,85 Tj = + 7 ºC Pdh 11,91 kW Tj = + 7 ºC COPd 5,08 Tj = + 12 ºC Pdh 13,76 kW Tj = + 12 ºC COPd 5,97 Tj = bivalent temperature Pdh 7,00 kW Tj = bivalent temperature COPd 2,72 Tj = operation limit Pdh 7,00 kW Tj = operation limit COPd 2,72 For air-to-water heat pumps: Tj = - 15 ºC (if TOL < - 20 ºC) Pdh 5,98 kW COPd 2,24 Bivalent temperature Tbiv -10 °C TOL -10 °C 10 W WTOL 58 °C Psup 0,00 kW Power input "compressor off" Power consumption in modes other than active mode POFF Off mode 5 W Thermostat-off mode PTO 24 W Standby mode PSB 11 W Crankcase heater mode PCK 0 W Other items Capacity control Sound power level, indoors/outdoors LWA Annual energy consumption QHE Contact details: fixed 61 2066 dB kWh For air-to-water heat pumps: Tj = - 15 ºC (if TOL < - 20 ºC) For air-to-water heat pumps: Operation limit temperature Heating water operating limit temperature Supplementary heater Rated heat output * Type of energy input electricity For air-to-water heat pumps: Rated air flow rate, outdoors - For water-/brine-to-water heat pumps: Rated brine or water flow rate, outdoor heat exchanger - 4100 Dimplex, * For heat pump space heaters and heat pump combination heaters, the rated heat output Prated is equal to the design load for heating Pdesignh, and the rated heat output of a supplementary heater Psup is equal to the supplementary capacity for heating sup(Tj). The calculation tool was made by Bundesverband Wärmepumpe BWP e.V. m3/h l/h Manufacturer: Dimplex Model: LA 12TU Air Low-temperature heat pump: no Equipped with a supplementary heater: Heat pump combination heater: no Application: medium Climate: average Item Rated heat output * no Symbol Value Unit Prated 6,63 kW Item Seasonal space heating energy efficiency Symbol Value Unit ƞS 115 % Declared coefficient of performance or primary energy ratio for part load at indoor temperature 20 °C and outdoor temperature Tj Declared capacity for heating for part load at indoor temperature 20 °C and outdoor temperature Tj Tj = - 7 ºC Pdh 7,22 kW Tj = - 7 ºC COPd 1,97 Tj = + 2 ºC Pdh 9,11 kW Tj = + 2 ºC COPd 2,84 Tj = + 7 ºC Pdh 11,17 kW Tj = + 7 ºC COPd 3,78 Tj = + 12 ºC Pdh 13,21 kW Tj = + 12 ºC COPd 4,74 Tj = bivalent temperature Pdh 6,63 kW Tj = bivalent temperature COPd 1,74 Tj = operation limit Pdh 6,63 kW Tj = operation limit COPd 1,74 For air-to-water heat pumps: Tj = - 15 ºC (if TOL < - 20 ºC) Pdh 5,65 kW COPd 1,37 Bivalent temperature Tbiv -10 °C TOL -10 °C 10 W WTOL 58 °C Psup 0,00 kW Power input "compressor off" Power consumption in modes other than active mode POFF Off mode 5 W Thermostat-off mode PTO 24 W Standby mode PSB 11 W Crankcase heater mode PCK 0 W Other items Capacity control Sound power level, indoors/outdoors LWA Annual energy consumption QHE Contact details: fixed 61 2066 dB kWh For air-to-water heat pumps: Tj = - 15 ºC (if TOL < - 20 ºC) For air-to-water heat pumps: Operation limit temperature Heating water operating limit temperature Supplementary heater Rated heat output * Type of energy input electricity For air-to-water heat pumps: Rated air flow rate, outdoors - For water-/brine-to-water heat pumps: Rated brine or water flow rate, outdoor heat exchanger - 4100 Dimplex, * For heat pump space heaters and heat pump combination heaters, the rated heat output Prated is equal to the design load for heating Pdesignh, and the rated heat output of a supplementary heater Psup is equal to the supplementary capacity for heating sup(Tj). The calculation tool was made by Bundesverband Wärmepumpe BWP e.V. m3/h l/h Manufacturer: Dimplex Model: LA 12TU Air Low-temperature heat pump: no Equipped with a supplementary heater: Heat pump combination heater: no Application: low Climate: warmer Item Rated heat output * no Symbol Value Unit Prated 9,40 kW Item Seasonal space heating energy efficiency Symbol Value Unit ƞS 203 % Declared coefficient of performance or primary energy ratio for part load at indoor temperature 20 °C and outdoor temperature Tj Declared capacity for heating for part load at indoor temperature 20 °C and outdoor temperature Tj Tj = - 7 ºC Pdh 7,60 kW Tj = - 7 ºC COPd 2,95 Tj = + 2 ºC Pdh 9,40 kW Tj = + 2 ºC COPd 3,62 Tj = + 7 ºC Pdh 11,72 kW Tj = + 7 ºC COPd 4,75 Tj = + 12 ºC Pdh 13,65 kW Tj = + 12 ºC COPd 5,89 Tj = bivalent temperature Pdh 9,40 kW Tj = bivalent temperature COPd 3,62 Tj = operation limit Pdh 9,40 kW Tj = operation limit COPd 3,62 For air-to-water heat pumps: Tj = - 15 ºC (if TOL < - 20 ºC) Pdh 6,00 kW COPd 2,34 Bivalent temperature Tbiv 2 °C TOL 2 °C 10 W WTOL 58 °C Psup 0,00 kW Power input "compressor off" Power consumption in modes other than active mode POFF Off mode 5 W Thermostat-off mode PTO 24 W Standby mode PSB 11 W Crankcase heater mode PCK 0 W Other items Capacity control Sound power level, indoors/outdoors LWA Annual energy consumption QHE Contact details: fixed 61 1336 dB kWh For air-to-water heat pumps: Tj = - 15 ºC (if TOL < - 20 ºC) For air-to-water heat pumps: Operation limit temperature Heating water operating limit temperature Supplementary heater Rated heat output * Type of energy input electricity For air-to-water heat pumps: Rated air flow rate, outdoors - For water-/brine-to-water heat pumps: Rated brine or water flow rate, outdoor heat exchanger - 4100 Dimplex, * For heat pump space heaters and heat pump combination heaters, the rated heat output Prated is equal to the design load for heating Pdesignh, and the rated heat output of a supplementary heater Psup is equal to the supplementary capacity for heating sup(Tj). The calculation tool was made by Bundesverband Wärmepumpe BWP e.V. m3/h l/h Manufacturer: Dimplex Model: LA 12TU Air Low-temperature heat pump: no Equipped with a supplementary heater: Heat pump combination heater: no Application: medium Climate: warmer Item Rated heat output * no Symbol Value Unit Prated 8,80 kW Item Seasonal space heating energy efficiency Symbol Value Unit ƞS 140 % Declared coefficient of performance or primary energy ratio for part load at indoor temperature 20 °C and outdoor temperature Tj Declared capacity for heating for part load at indoor temperature 20 °C and outdoor temperature Tj Tj = - 7 ºC Pdh 7,17 kW Tj = - 7 ºC COPd 1,88 Tj = + 2 ºC Pdh 8,80 kW Tj = + 2 ºC COPd 2,32 Tj = + 7 ºC Pdh 10,53 kW Tj = + 7 ºC COPd 3,05 Tj = + 12 ºC Pdh 12,95 kW Tj = + 12 ºC COPd 4,41 Tj = bivalent temperature Pdh 8,80 kW Tj = bivalent temperature COPd 2,32 Tj = operation limit Pdh 8,80 kW Tj = operation limit COPd 2,32 For air-to-water heat pumps: Tj = - 15 ºC (if TOL < - 20 ºC) Pdh 5,72 kW COPd 1,50 Bivalent temperature Tbiv 2 °C TOL 2 °C 10 W WTOL 58 °C Psup -0,00 kW Power input "compressor off" Power consumption in modes other than active mode POFF Off mode 5 W Thermostat-off mode PTO 24 W Standby mode PSB 11 W Crankcase heater mode PCK 0 W Other items Capacity control Sound power level, indoors/outdoors LWA Annual energy consumption QHE Contact details: fixed 61 1336 dB kWh For air-to-water heat pumps: Tj = - 15 ºC (if TOL < - 20 ºC) For air-to-water heat pumps: Operation limit temperature Heating water operating limit temperature Supplementary heater Rated heat output * Type of energy input electricity For air-to-water heat pumps: Rated air flow rate, outdoors - For water-/brine-to-water heat pumps: Rated brine or water flow rate, outdoor heat exchanger - 4100 Dimplex, * For heat pump space heaters and heat pump combination heaters, the rated heat output Prated is equal to the design load for heating Pdesignh, and the rated heat output of a supplementary heater Psup is equal to the supplementary capacity for heating sup(Tj). The calculation tool was made by Bundesverband Wärmepumpe BWP e.V. m3/h l/h
© Copyright 2026 Paperzz