Discrete Signal Protection (Ground Referenced Circuits) PT 4x1 and PT 2x1 Series Brochure 1364B February 2003 Description Ground referenced signals such as discrete I/O (binary) should be protected with the PT 4x1 series. Each PT 4x1 can protect up to 4 discrete I/O signal circuits (using a common return). The circuit design features a hybrid circuit providing line-to-ground protection with fast acting SAD components and highpowered GDT technology. As with the other PLUGTRAB PT series, the protection is achieved in a “hot-swap” plug unit allowing, quick maintenance and diagnostics. For applications where only two discrete signals are to be protected, the PT 2x1 series plugs are available. The footprint and packaging is identical to the other PT series. The protection circuit is connected using pins 7, 11/8,12. Figure 12. Circuit Diagram with PT 4x1-BE Ordering Information PT 4x1-5DC-ST – Plug for four 5 V dc discrete circuits PT 4x1-12DC-ST – Plug for four 12 V dc discrete circuits PT 4x1-24DC-ST – Plug for four 24 V dc discrete circuits 28 38 30 6 PT 4x1-12AC-ST – Plug for four 12 V ac discrete circuits PT 4x1-24AC-ST – Plug for four 24 V ac discrete circuits 28 38 34 8 PT 4x1-BE – Base element for PT 4x1 plugs PT 4x1+F-BE – Base element with integrated gas discharge tube for PT 4x1 plugs 28 39 36 3 28 38 31 9 28 38 32 2 Figure 13. Circuit Diagram with PT 4x1+F-BE 28 38 35 1 Note: indicates potential earth also called earth ground. This is the same potential as the DIN-rail mounting foot. 1364A029 28 39 37 6 Phoenix Contact Inc. • P.O. Box 4100 • Harrisburg, PA 17111 • Phone: (717) 944-1300 • Fax: (717) 944-1625 13 Brochure1364B Discrete Signal Protection (Ground Referenced Circuits) PT 4x1 and PT 2x1 Series Ordering Information Figure 14. Circuit Diagram with PT 2x1-BE PT 2x1-5DC-ST – Plug for two 5 V dc circuits PT 2x1-12DC-ST – Plug for two 12 V dc circuits PT 2x1-24DC-ST – Plug for two 24 V dc circuits 28 56 06 1 PT 2x1-12AC-ST – Plug for two 12 V ac circuits PT 2x1-24AC-ST – Plug for two 24 V ac circuits 28 56 09 0 PT 2x1-BE – Base element for PT 1x2 plugs PT 2x1+F-BE – Base element with integrated gas discharge tube for PT 1x2 plugs 28 56 13 9 Figure 15. Circuit Diagram with PT 2x1+F-BE Note: indicates potential earth also called earth ground. This is the same potential as the DIN-rail mounting foot. 1364A029 Table 4. PT 4x1 and PT 2x1 Technical Specifications Phoenix Contact Inc. • P.O. Box 4100 • Harrisburg, PA 17111 • Phone: (717) 944-1300 • Fax: (717) 944-1625 Brochure 1364B 14 28 56 07 4 28 56 08 7 28 56 10 0 28 56 14 2 Discrete Signal Protection (Ground Referenced Circuits) PT 4x1 and PT 2x1 Series Figure 16. Wiring Diagram When to use PT 4x1-BE and PT 2x1-BE base elements without gas tube isolation: The PT 4x1-BE and PT 2x1-BE base elements are best suited for discrete circuit installations where the common reference (to or from the I/O) is to be grounded at the termination point. These versions of the base element do NOT include the isolation from return to ground. This means positions 9, 10 and 3, 4 are electrically the same. Phoenix Contact Inc. • P.O. Box 4100 • Harrisburg, PA 17111 • Phone: (717) 944-1300 • Fax: (717) 944-1625 15 Brochure1364B Discrete Signal Protection (Ground Referenced Circuits) PT 4x1 and PT 2x1 Series Figure 17. Wiring Diagram When to use PT 4x1+F-BE and PT 2x1+F-BE base elements with gas tube isolation: The PT 4x1+F-BE and PT 2x1+F-BE base elements are best suited for discrete circuit installations where the common reference (to or from the I/O) is to be ungrounded (floating) at the termination point. The integrated gas tube then supplies isolation between the ungrounded common at position 9 (IN) and 10 (OUT) and the earth ground at position 3 (IN) and 4 (OUT). Phoenix Contact Inc. • P.O. Box 4100 • Harrisburg, PA 17111 • Phone: (717) 944-1300 • Fax: (717) 944-1625 Brochure 1364B 16
© Copyright 2026 Paperzz