- The range hood must be located 65cm above the cooking appliance unless specified otherwise. May be reduced to 60cm to align with the AGA code. - "IMPORTANT" : "INSTALLATION HEIGHTS IN AUSTRALIA" 1) Where an Electric Cooktop is installed under this Rangehood THE MINIMUM DISTANCE between the Top of the Cooktop and the underside of the Rangehood - MUST BE 60cm and the maximum 70 cm. 2) When this Rangehood is installed over a Gas fuelled Cooktop THE MINIMUM DISTANCE between the Top of the Pot rests and the underside of the Hood - MUST BE 65cm and the maximum 75 cm. - FOR INSTALLATION OVER A GAS RANGE OR GAS COOKING HOB A DIFFERENT SPECIFIC MINIMUM HEIGHT REQUIREMENT MAY BE REQUIRED BY THE RELEVANT GAS AUTHORITIES. - IF THE SUPPLY CORD IS DAMAGED, IT MUST BE REPLACED BY THE MANUFACTURER OR ITS SERVICE AGENT OR A SIMILARY QUALIFIED PERSON IN ORDER TO AVOID A HAZARD. - THE APPLIANCE IS NOT INTENDED FOR USE BY YOUNG CHILDREN OR INFIRM PERSONS WITHOUT SUPERVISION. - YOUNG CHILDREN SHOULD BE SUPERVISED TO ENSURE THAT THEY DO NOT PLAY WITH THE APPLIANCE. - DO NOT USE THE RANGEHOOD LIGHTS AS A NIGHT LIGHT. - MOST SMEG RANGE HOODS ARE FITTED WITH A METAL WASHABLE GREASE FILTER. CLEANING CAN BE ATTENDED BY HAND, OR PER DISHWASHER. SHOULD YOUR MODEL BE FITTED WITH A FIBRE GREASE FILTER, THIS CAN BE WASHED AND REUSED UNTIL AT WHICH TIME IT SHOULD BE REPLACED. SAFETY WARNINGS RANGE HOODS • THERE SHALL BE ADEQUATE VENTILATION OF THE ROOM WHEN THE RANGE HOOD IS USED AT THE SAME TIME AS APPLIANCES BURNING GAS OR OTHER FUELS. (NOT APPLICABLE TO APPLIANCES THAT ONLY DISCHARGE THE AIR BACK INTO THE ROOM) • THERE IS A RISK OF FIRE IF CLEANING IS NOT CARRIED OUT IN ACCORDANCE WITH THE INSTRUCTIONS. • DO NOT FLAMBÉ UNDER THE RANGE HOOD. • CAUTION: ACCESSIBLE PARTS MAY BECOME HOT WHEN USED WITH A COOKING APPLIANCE. • THE APPLIANCE IS NOT INTENDED FOR USE BY PERSONS (INCLUDING CHILDREN) WITH REDUCED PHYSICAL, SENSORY OR MENTAL CAPABILITIES, OR LACK OF EXPERIENCE AND KNOWLEDGE, UNLESS THEY HAVE BEEN GIVEN SUPERVISED OR INSTRUCTION CONCERNING USE OF THE APPLIANCE BY A RESPONSIBLE PERSON FOR THEIR SAFELY. • YOUNG CHILDREN SHOULD BE SUPERVISED TO ENSURE THAT THEY DO NOT PLAY WITH THE APPLIANCE. • IF THE SUPPLY CORD IS DAMAGED, IT MUST BE REPLACED BY THE MANUFACTURER OR ITS SERVICE AGENT OR A SIMILARLY QUALIFIED PERSON IN ORDER TO AVOID A HAZARD. FOR INSTALLATION INSTRUCTIONS: • THE EXHAUST AIR MUST NOT BE DISCHARGED INTO A FLUE WHICH IS USED FOR EXHAUSTING FUMES FROM OTHER APPLIANCES BURNING GAS OR OTHER FUELS. (NOT APPLICABLE FOR APPLIANCES WHICH ONLY DISCHARGE AIR BACK INTO THE ROOM) • THE MINIMUM DISTANCE BETWEEN THE SUPPORTING SURFACE FOR THE COOKING VESSELS ON THE HOB AND THE LOWEST PART OF THE RANGE HOOD: WHEN THE RANGE HOOD IS LOCATED ABOVE A GAS APPLIANCE, THIS DISTANCE SHALL BE 65CM. IF THE INSTRUCTIONS FOR INSTALLATION FOR THE GAS HOB SPECIFY A GREATER DISTANCE, THIS MUST BE TAKEN INTO ACCOUNT. (THE DISTANCE OF 65CM CAN BE REDUCED FOR NON COMBUSTIBLE PARTS OF RANGE HOODS AND PARTS OPERATING AT SAFETY EXTRA LOW VOLTAGE PROVIDED THESE PARTS DO NOT GIVE ACCESS TO LIVE PARTS. THE VALUE OF 65CM. MAY BE REDUCED TO 60CM. SO AS TO ALIGN WITH AS 560 1 GAS INSTALLATION. • REGULATIONS CONCERNING THE DISCHARGE OF AIR HAVE TO BE FULFILLED 04308297/2 Italiano, 10 English, 12 Deutsch, 14 Français, 16 Español, 18 Português, 20 Nederlands, 22 Ðóññêèé, 24 Dansk, 26 Suomi, 28 Svenska, 30 ÅëëçíéêÜ, 32 Română, 34 Čeština, 36 Slovensky, 38 Istruzioni per l’uso Instructions for use Betriebsanleitung Mode d’emploi Instrucciones de uso Instruções de uso Gebruiksaanwijzingen Ðóêîâîäñòâî ïî ýêñïëóàòàöèè Brugsanvisning Käyttöohjeet Bruksanvisning Ïäçãßåò ÷ñÞóçò Instrucţiuni de utilizare Návod k použití Návod na používanie 1x 4x 1x 3.9x6mm 2x 1x ø 15cm 1x ø 12.5cm 2x 8x 8x 4.8x38mm 1x 1x 1x 1x 1x 2x 3.9 x 6mm 2 1x ! ! L = 65 cm min. 1A Ø150mm Ø150mm 1B Ø125 Ø125 Ø150 3 2 5 4.8 x 38 mm 6 3 55 mm MIN. 1215mm. 4 4 7 8 11 9 12 10 13 Ø 8 mm 4.8 x 38 mm 5 17 14 3.9 x 6 mm Ø 8 mm 325 mm 15 18 = 16 = 19 4.8 x 38 mm 6 20A 23A 21A 24A 3.9 x 6 mm 22A 20B 7 21B 24B 3.9 x 6 mm 8 22B 25B 23B 26B 27B 30B 28B 31B 29B 32B 9 English EN ! The appliance must be installed by a qualified person in compliance with the instructions provided. CONTROLS ! P1 Wear gloves when carrying out installation and maintenance operations. AIR VENT (for ducting versions) ! Prepare the hole and the air vent duct (150 mm diameter). ! Use a duct of the minimum indispensible length. ! Use a duct with as few elbows as possible (maximum elbow angle: 90°). ! Avoid drastic changes in the duct cross-section. ! Use a duct with an as smooth as possible inside. ! The duct must be made of certified material. ! Do not connect the hood to smoke exhaust ducts for the products of combustion (boilers, fireplaces, stoves, etc). ! For the air vents comply with the provisions laid down by the competent authorities. In addition, the air must not be evacuated through a hole in the wall unless specifically intended for this purpose. ! Fit air intakes in the room to prevent the hood from creating a negative pressure in the room (which must not exceed 0.04 mbar); if the hood is used at the same time as non-electrical equipment (gas-, oil- and charcoal-fired stoves, etc.) the exhaust gas may be sucked in by the heat source. FILTERING OR DUCTING VERSION ? The hood may be in filtering or in ducting version. Decide from the outset which type is to be installed. For better efficiency, we recommend installing the hood in the ducting version (if possible). Ducting version The hood purifies the air and evacuates it to the outside through an exhaust duct (diameter 150 mm). Filtering version The hood purifies the air and recycles the clean air back into the room. 12 P3 P5 P4 P2 L1 P1: 5’ TIMER P2: Filter alarm reset P3: Motor off / speed decrease – . - holding down the button, the motor turns off storing the current speed P4: Motor on / speed increase P5: Lights on/off L1 Signalling crown: - Hood in standby: lights up amber-orange. 30” after the last key has been pressed the crown turns off - Motor on: L1 lights up turquoise flashing. The flashing frequency is proportional to the speed - 5’ TIMER function : L1 lights up turquoise fixed - Filter alarm active: L1 lights up red fixed (30h); L2 lights up red flashing (120h) MAINTENANCE ! Before cleaning or maintenance cut the power. Cleaning the hood WHEN TO CLEAN IT: clean it at least every 2 months to prevent the risk of fire. EXTERNAL CLEANING: use a cloth moistened in lukewarm water and neutral detergent (for painted hoods); use specific products for steel, copper or brass hoods. INTERNAL CLEANING: use a cloth (or brush) soaked in denatured ethyl alcohol. WHAT NOT TO DO: do not use abrasive or corrosive products (e.g. metal sponges, brushes, too hard brushes, very aggressive detergents, etc.) Cleaning the grease filters WHEN TO CLEAN IT: clean it at least every 2 months to prevent the risk of fire. HOW TO REMOVE THE FILTERS: push the catch near the handle towards the rear of the hood and pull the filter downwards HOW TO CLEAN THE FILTERS: hand wash or in the dishwasher using a neutral detergent. If washing in the dishwasher, possible discoloration of the filters does not in any way compromise their functioning. Replacing the charcoal filter (P) (for filtering version only) WHEN TO REPLACE IT: replace it at least every 6 months. HOW TO REMOVE IT: if using the hood in the filtering version, the charcoal filter has to be replaced. To remove it, push the catch inwards and remove the charcoal filter from its seat. MALFUNCTIONS If something appears not to be working properly, do the following simple checks before calling Technical Service: • If the hood is not working: Check that: - The power has not been disconnected. - A speed has been selected. • If the hood performs inefficiently: Check that: - The motor speed selected is sufficient for the amount of smoke and vapours released. - The kitchen is sufficiently ventilated to allow air intake. - The charcoal filter is not worn (hood in filtering version). • If the hood has turned off during normal functioning: Check that: - The power has not been disconnected. - the omnipolar disconnection device has not tripped. P Components not provided with the product Replacing the lamps - To change the halogen lamps open the cover levering from the proper slots. - Replace it with a lamp of the same type. WARNING: Do not touch the new lamp with bare hands. 13 EN
© Copyright 2025 Paperzz