P R E - I N S TA L L AT I O N G U I D E for MODELS DENTAL VACUUM SYSTEMS VS50NEO & VS80NEO C he ck VacS t ar NEO Model Bein g I n st alled: VS50NEO VS80NEO Doctor:__________________________________________________ Address:__________________________________________________ Phone#:__________________________________________________ Dealer:__________________________________________________ Dealer Address: __________________________________________________ PRODUCT SPECIFICATIONS Electrical Voltage Rating (VAC) Voltage Min./Max. (VAC) Frequency Single Phase (Hz) Full Load (Amps) Model VS50NEO Model VS80NEO 220 220 198/242 198/242 50/60 50/60 20 28 20 - 100 20 - 100 0.13 0.13 40 - 75 40 - 75 10 10 Water Inlet Water Pressure (PSI) Flow Rate (gal/min) per Pump Inlet Water Temperature (°F) Vacuum Level Preset at Factory (in Hg) All installations must conform to local codes. PHYSICAL CHARACTERISTICS Model VS50NEO Model VS80NEO Height 23 inches (58 cm) Height 23 inches (58 cm) Width 28 inches (71 cm) Width 28 inches (71 cm) Depth 18 inches (46 cm) Depth 18 inches (46 cm) 18 in. 18 in. 28 in. 28 in. 23 in. 23 in. Shipping Weight Shipping Weight 175 lbs. (79 kg) 175 lbs. (79 kg) ELECTRICAL CONNECTIONS 220V Connections: Each pump has its own 6-foot BX cable pre-wired to the electrical connection box for direct wiring to dedicated 220VAC, single phase 50/60 Hz circuit via a disconnect box with approved ground. Disconnect box should be mounted no more than 3 feet of each other and 3 feet of installation center line. The supplied cable is pre-wired in the electrical box of each pump. Connect cable wires by matching color. Important: When not connecting a 24VDC remote switch, the ORG and YEL wires must be tied together and the BRN wire insulated for pump operation. 24VDC Connections: 24VDC Connections are used when installing a 24VDC remote switch. They are made via a supplied interconnect cable that is also pre-wired to the electrical connection box of each pump. Make the 24VDC connections shown below for the remote switch. When not using the remote switch, insulate the BRN wire and tie the ORG and YEL wires together. Green Yellow Stripe Remote Switch Terminal Board BRN Black ORN YEL Supplied 6-Foot BX Cable from the Electrical Connection Box of Each Pump ED CL BRN Interconnect Cable ORN Interconnect Cable YEL White GRN 2 Yel 3 Org Remote Switch 4 Brn Connection without 24VDC Switch 220VAC Connections A S S IF I Interconnect Cable 24VDC Connections MEDICAL ELECTRICAL EQUIPMENT WITH RESPECT TO ELECTRICAL SHOCK, FIRE, MECHANICAL AND OTHER SPECIFIED HAZARDS ONLY IN ACCORDANCE WITH UL-60601-1, CAN/CSA C22.2 NO.601.1 66CA UTILITY ROOM CONFIGURATION VacStar NEO without Wall-Mounted Air/Water Separator Note: All VacStar NEOs are hard-wired directly to the VacStar’s electrical box via a 4-inch handy box complying with local electrical codes. The 4-inch handy box is not supplied. Intake from Main Line terminate with 1” FNPT fitting Water Suppy 1/2” copper tube terminate with 1/2” FNPT shut-off valve Drain Hose Floor Drain Note: See Optional Drain Connections VacStar NEO with Wall-Mounted Air/Water Separator Intake from Main Line terminate with 1” FNPT fitting Water Suppy 1/2” copper tube terminate with 1/2” FNPT shut-off valve Vent Vent to outside with 2” schedule 40 pipe Air/Water Separator WARNING: Condensation of water will occur in vent piping. Slope piping toward separator to avoid accumulation of water in vent. Note: All VacStar NEOs are hard-wired directly to the VacStar’s electrical box via a 4-inch handyPower box complying Connection with local electrical codes. The 4-inch handy box is not supplied. 32 Inches Maximum. Drain Hose Floor Drain Note: See Optional Drain Connections All VacStar NEO vacuums comply with NFPA 99C level 3 requirements PLUMBING INSTALLATION SUB FLOOR INSTALLATION - The sub-floor plumbing layout shown below is the recommended layout for VacStar system installations and should be used whenever possible. 2-Inch Exhaust/Vent Ceiling Interior Wall Notes: 1. See Optional Drain Connections shown below. Black Flex Tubing 2. 8-Foot Maximum Height from Main Line to pump. See Note 1 Junction Box 1/2-Inch Diameter Riser Minumum Slope: 1/4 inch per 10 Feet From Dental Unit 1/2 Inch Riser 45°Elbow 5. When main line is 1-1/2" I.D. or larger, use 45° Y's and elbows only. 6. Long radius 90° elbows can be used as alternates to 45° elbows. Riser - See Note 2 MAIN LINE See Plumbing Requirements for Main Line Diameters needed for specific units. See Notes 3, 4 & 5. 45°Y Main Line 3. Consult Dental Unit Manufacturer's Guidelines for correct reduced size and height of termination of vacuum line inside junction box. 4. Limit branches. Orient main line under junction box or cabinet. Floor Sink To Pump RISER to MAIN LINE DETAIL OVERHEAD INSTALLATION - The overhead plumbing layout shown below is the alternate layout for VacStar system installations and should be used only when unable to use the sub-floor plumbing layout. 45°Elbow 45°Elbow MAIN LINE See Plumbing Requirements for Main Line Diameters needed for specific units. 1" Min 1/2 Inch Riser Main Line Interior Wall 1/2-Inch Riser Ceiling 2-Inch Exhaust/Vent 1/2-Inch Diameter Riser Dental Unit 10-Foot Maximum Height from Riser Trap to Main Line Black Flex Tubing Floor Sink Junction Box 1/2-Inch RISER TRAP DETAIL (Using 45° Elbows) 45°Y To STS Pump RISER to MAIN LINE DETAIL Minumum Slope: 1/4 inch per 10 Feet To Main Line 1/2 Inch Diameter Note: Consult Dental Unit Manufacturer's Guidelines for correct reduced size and height of termination of vacuum line inside junction box. Note: See Optional Drain Connections CONNECTION DETAILS ALL INSTALLATIONS 45° Elbow MAKING TURNS MAIN LINE O DO NOT use 90° elbows except where main line terminates at vacuum pump. CLEARING AN OBSTRUCTION DRAIN OPTIONS Direct connection to vented drain. No traps before vent. OR O Use only 45° elbows to make turns in main line. 45° Elbow O If piping is diverted to clear an obstruction, DO NOT MAKE A TRAP. CLOSED VENTED DRAIN All installations must conform to local codes. Indirect connection (Air gap) with a p-trap. 6” 1-1/2 Inch P-Trap OPEN DRAIN PIPE SITE REQUIREMENTS Electrical Minimum Circuit Breaker Rating Minimum Wire Gauge Size 220-Volt Buck/Boost Transformer VS50NEO VS80NEO 2 X 15 or 30A 2 X #12 AWG or 1 X #10 AWG #67002 (3.4 KVA) 2 X 20 or 40A 2 X #12 AWG or 1 X #8 AWG #67002 (3.4 KVA) Plumbing Note: Suction piping must slope at least a ¼” for each 10 feet of run towards the pump. Use PVC Schedule 40 or Copper Type M. Minimum CFM @ 0" Hg Air Exhaust with Air/Water Separator 30 2" schedule 40 pipe 40 2" schedule 40 pipe Overhead Plumbing Main Line Diameter (Min./Max. ID in inches) End Fitting Overhead Main Line 1 to 1½" / ” FNPT ½" ID 1¼ to 2" / ” FNPT ½" ID 3 4 3 4 1 to 1½" / ” FNPT 3/4 ” to 1½” 3 4 Floor Plumbing Main Line Diameter (Min./Max. ID in inches) End Fitting Branch Line Diameter (Min./Max. ID in inches) 3 4 1¼ to 2" / ” FNPT 1 to 1½” Environmental 40 to 104°F (5 to 40°C) Ambient Temperature (See ventilation requirements below.) 40 to 104°F (5 to 40°C) VENTILATION REQUIREMENTS Equipment Room Temperature The VacStar NEO equipment must be used in a controlled temperature environment. Maintain equipment room temperature between 40 and 105 degrees Fahrenheit. Adequate forced ventilation must be provided across the unit by placing an appropriate exhaust fan opposite an equivalent air intake vent. The fan should be higher than the associated intake vent. Exhaust Vent Protection. If the exhaust piping is venting to the outside of the building, precautions must be taken to protect the equipment room from weather elements and animal intrusion. This can be accomplished by using one of the three methods shown below. Shroud & Screen Screen Roof-Mounted Outside Vent Protection Shroud & Screen Wall-Mounted Outside Vent Protection Make sure to use the required pipe type for associated system NOTES NOTES For over 50 years, Air Techniques has been a leading innovator and manufacturer of dental products. Our priority is ensuring complete satisfaction by manufacturing reliable products and providing excellent customer and technical support. Whether the need is digital imaging, utility room equipment or merchandise, Air Techniques can provide the solution via our network of authorized professional dealers. Proudly designed, tested and manufactured in the U.S., our products are helping dental professionals take their practices to the next level. Air Techniques’ family of quality products for the dental professional include: Digital Imaging • • • • • • Utility Room • • • • • • Digital Radiography Intraoral Camera Caries Detection Aid Intraoral X-ray Panoramic X-ray Film Processors Dry Vacuums Wet Vacuums Air Compressors Amalgam Separator Utility Accessories Utility Packages Merchandise • • • • • • • • Surface Disinfectant Enzymatic Cleaner Hand Sanitizer and Lotion Waterline Cleaner Evacuation System Cleaner Imaging Accessories Chemistry Processor Accessories Corporate Headquarters 1295 Walt Whitman Road | Melville, New York 11747- 3062 | Phone: 800-247-8324 | Fax: 888-247-8481 Western Facility 291 Bonnie Lane, Suite 101 | Corona, CA 92880 - 2804 | Phone: 800-247-8324 | Fax: 951-898-7646 www. air tec hniques.c om VacStar is a registered trademark of Air Techniques, Inc. © Air Techniques, Inc. • P/N K1106 Rev. A • February 2016
© Copyright 2026 Paperzz