EBARA Submersible Sewage Pumps Contents Project: Model: Chk

DLFU
EBARA Submersible Sewage Pumps
Contents
Project:
Model:
Model DLFU
50DLFU61.5
80DLFU61.5
80DLMFU61.5
80DLFU62.2
80DLMFU62.2
80DLFU63.7
80DLMFU63.7
80DLFU65.5
80DLMFU65.5
80DLFU67.5
80DLCMFU67.5
80DLFU611
80DLCMFU611
80DLFU615
80DLFU618
80DLFU622
100DLFU61.5
100DLFU62.2
100DLMFU62.2
100DLFU63.7
100DLMFU63.7
100DLFU65.5
100DLMFU65.5
100DLFU67.5
100DLMFU67.5
100DLFU611
100DLMFU611
100DLFU615
100DLMFU615
100DLFU618
100DLMFU618
100DLFU622
100DLMFU622
100DLFU630
Section
Specifications
Selection Chart
Performance Curves
Outline Drawings
Sectional View
QDC Information
Technical Information
100DLFU637
100DLFU645
150DLFU67.5
150DLFU611
150DLFU615
150DLFU618
150DLFU622
150DLFU630
150DLFU637
150DLFU645
200DLFU67.5
200DLFU611
200DLFU615
200DLFU618
200DLFU622
200DLFU630
200DLFU637
200DLFU645
Chk’d:
Date:
250DLFU611
250DLBFU615
250DLCFU615
250DLFU618
250DLFU622
250DLFU630
250DLFU637
250DLFU645
300DLFU618
300DLFU622
300DLFU630
300DLFU637
300DLFU645
Page
2-158
2-165
2-166
2-191
2-210
2-278
2-289.1
material specification
impeller description
motor protection
cable entry
paint specifications
mechanical seal
general
Motor Data
2-315.1
motor electrical specifications
cable data
wiring diagrams
motor electrical data
EBARA Fluid Handling
www.pumpsebara.com
(t) 803 327 5005 • (f) 803 327 5097
2-155
rev. 11/02
DLFU
EBARA Submersible Sewage Pumps
Contents
Project:
Model:
EBARA Fluid Handling
www.pumpsebara.com
(t) 803 327 5005 • (f) 803 327 5097
Chk’d:
Date:
2-156
rev. 01/02
DLFU
EBARA Submersible Sewage Pumps
Model Designation
Project:
Model:
Chk’d:
100
DLF/
DLMF
U
6
Date:
1.5
2
DISCHARGE SIZE – mm
50mm – 2"
200mm – 8"
80mm – 3"
250mm – 10"
100mm – 4"
300mm – 12"
150mm – 6"
MODEL TYPE
DLF/DLMF – submersible sewage pump
DLFM/DLMFM – FM explosion proof designation
GEOGRAPHIC DESIGNATION
U – U.S.A. market
HERTZ
6 - 60
RATED KW
1.5 – 2HP
2.2 – 3HP
3.7 – 5HP
5.5 – 71/2HP
7.5 – 10HP
11 – 15HP
15 – 20HP
18 – 25HP
22
30
37
45
–
–
–
–
30HP
40HP
50HP
60HP
PHASE
none – three phase
VOLTAGE
2 - 208/230
4 - 460
5 - 575
EBARA Fluid Handling
www.pumpsebara.com
(t) 803 327 5005 • (f) 803 327 5097
2-157
rev. 01/02
DLFU
EBARA Submersible Sewage Pumps
Specifications
Project:
Model:
Chk’d:
Date:
Model DLFU
Specifications
Standard
Size
2, 3, 4, 6, 8, 10, 12 inch
Range of HP
Range of Performance
2 to 60 HP
Capacity 13 to 4000 GPM
Head 7 to 243 feet
Limitation
Maximum Water Temperature
Synchronous Speed
Materials
Casing
Impeller
Shaft
Motor Frame
Fastener
Mechanical Seal
Material – Upper Side
Material – Lower Side
Impeller Type
Bearing
Motor
Three Phase
Service Factor
Motor Protection
Submersible cable
Optional
104°F ( 40°C)
1800 RPM
Cast Iron
Cast Iron (2 to 60HP)
Ductile Iron (150-300 DLFU 40 to 60 HP)
403 Stainless Steel (2 to 5HP)
420 Stainless Steel (71/2 to 60HP)
Cast Iron
304 Stainless Steel
Double Mechanical Seal
Carbon/Ceramic (2 to 60HP)
Silicon Carbide/Silicon Carbide (2 to 60HP)
Tungsten Carbide/Tungsten Carbide (150-300 DLFU
50 and 60HP only)
Semi-open (2 to 30HP)
Enclosed (40 to 60HP)
Prelubricated Ball Bearing
Insulation Class F (2-5HP), H (71/2 to 60HP)
208/230/460V
1.15
Thermal Detector – Klixons
Mechanical Seal Leakage Detector – Float Switch
33 ft. (2 to 5HP)
50 ft. (71/2 to 60HP)
Accessories
EBARA Fluid Handling
www.pumpsebara.com
(t) 803 327 5005 • (f) 803 327 5097
Tungsten Carbide/Tungsten Carbide
Tungsten Carbide/Tungsten Carbide
FM Explosion Proof, Class 1,
Division 1, Group C, D
____ ft. (customer specified)
QDC System
2-158
rev. 02/13
DLFU
EBARA Submersible Sewage Pumps
Specifications
Project:
Model:
Chk’d:
Date:
A. General:
Provide submersible sewage pumps suitable for continuous duty operation underwater without loss of watertight
integrity to a depth of 65 feet. Pump system design shall include a guide rail system be such that the pump will be
automatically connected to the discharge piping when lowered into place on the discharge connection. The pump
shall be easily removable for inspection or service, requiring no bolts, nuts, or other fasteners to be disconnected, or
the need for personnel to enter the wet well. The motor and pump shall be designed, manufactured, and assembled
by the same manufacturer.
B. Manufacturer:
EBARA International Corporation
C. Pump Characteristics:
Pumps shall conform to the following requirements:
Number of units
Design flow (gpm)
Design TDH (ft)
Minimum shut off head (ft)
RPM
Maximum HP
Minimum efficiency at design (%)
Minimum power factor at design (%)
Voltage/HZ
Phase
1800
208/230V, 460V / 60
3
D. Pump Construction:
All major parts of the pumping unit(s) including casing, impeller, suction cover, wear rings, motor frame and discharge
elbow shall be manufactured from gray cast iron, ASTM A-48 Class 30. Castings shall have smooth surfaces devoid
of blow holes or other casting irregularities. Casing design shall be centerline discharge with a large radius on the
cut water to prevent clogging. Units shall be furnished with a discharge elbow and 125 lb. flat face ANSI flange. All
exposed bolts and nuts shall be 304 stainless steel. All mating surfaces of major components shall be machined and
fitted with NBR o-rings where watertight sealing is required. Machining and fitting shall be such that sealing is
accomplished by automatic compression of o-rings in two planes and o-ring contact is made on four surfaces without
the requirement of specific torque limits. Internal and external surfaces are prepared to SPPC-VISI-SP-3-63 then
coated with a zinc-chromate primer. The external surfaces are then coated with a H.B. Teneme-Tar 46H-413 Polyamide
Epoxy - Coal Tar paint
1. Impellers:
a. For units 2 to 5 HP, the impeller shall be radial single or multi-vane, semi-open design. It shall be dynamically
balanced and shall be designed for solids handling with a long thrulet without acute turns. The inlet edge of the
impeller vanes shall be angled toward the impeller periphery so as to facilitate the release of objects that might
otherwise clog the pump. The 2 to 5 HP impeller design shall also include back pump out vanes to reduce the
pressure and entry of foreign materials into the mechanical seal area. In addition, a lip seal shall be located
behind the impeller hub to further reduce the entry of foreign materials into the seal area. Impellers shall be direct
connected to the motor shaft with a slip fit, key driven, and secured with an impeller bolt. The design shall include
a replaceable cast iron suction cover. The suction cover shall be designed such that it may be adjusted to maintain
working clearances and hydraulic efficiencies.
b. For units 71/2 to 30 HP, the impeller shall be a mixed flow multi-vane semi-open design. It shall be dynamically
balanced and shall be designed for solids handling with a long thrulet without acute turns. The inlet edge of the
impeller vanes shall be angled toward the impeller periphery so as to facilitate the release of objects that might
otherwise clog the pump. The 71/2 to 30 HP impeller design shall also include back pump out vanes to reduce the
pressure and entry of foreign materials into the mechanical seal area. In addition, a lip seal shall be located
behind the impeller hub to further reduce the entry of foreign materials into the seal area. Impellers shall be direct
EBARA Fluid Handling
www.pumpsebara.com
(t) 803 327 5005 • (f) 803 327 5097
2-159
rev. 10/11
DLFU
EBARA Submersible Sewage Pumps
Specifications
Project:
Model:
Chk’d:
Date:
connected to the motor shaft with a slip fit, key driven, and secured with an impeller bolt. The design shall include
a replaceable cast iron suction cover. The suction cover shall be designed such that it may be adjusted to maintain
working clearances and hydraulic efficiencies.
c. For high head units with 4'' discharge, 40 to 60 HP shall have a radial multi-vane, enclosed impeller design. It
shall be dynamically balanced and shall be designed for solids handling with a long thrulet without acute turns.
The inlet edge of the impeller vanes shall be angled toward the impeller periphery so as to facilitate the release
of objects that might otherwise clog the pump. A lip seal shall be located behind the impeller hub to reduce the
entry of foreign materials into the mechanical seal area. Impellers shall be direct connected to the motor shaft
with a slip fit, key driven, and secured with an impeller bolt. The design shall include a replaceable casing wear
ring at the pump suction to maintain working clearances and hydraulic efficiencies.
d. For units 6'' to 12'' discharge sizes, 40 to 60 HP, the impeller shall be a mixed flow multi-vane enclosed design. It
shall be dynamically balanced and shall be designed for solids handling with a long thrulet without acute turns.
The inlet edge of the impeller vanes shall be angled toward the impeller periphery so as to facilitate the release
of objects that might otherwise clog the pump. A lip seal shall be located behind the impeller hub to reduce the
entry of foreign materials into the seal area. Impellers shall be direct connected to the motor shaft with a slip fit,
key driven, and secured with an impeller bolt. The design shall include a replaceable casing wear ring at the
pump suction to maintain working clearances and hydraulic efficiencies.
optional K-series design:
e. For units 2 to 5 HP, the impeller shall be radial single or multi-vane, semi-open design. It shall be dynamically
balanced and shall be designed for solids handling with a long thrulet without acute turns. The inlet edge of the
impeller vanes shall be angled toward the impeller periphery so as to facilitate the release of objects that might
otherwise clog the pump. The 2 to 5 HP impeller design shall also include back pump out vanes to reduce the
pressure and entry of foreign materials into the mechanical seal area. In addition, a lip seal shall be located behind
the impeller hub to further reduce the entry of foreign materials into the seal area. Impellers shall be direct connected
to the motor shaft with a slip fit, key driven, and secured with an impeller bolt. The design shall include a replaceable
cast iron suction cover. The suction cover shall contain a groove(s) perpendicular to the suction opening to disrupt
fibrous solids that may otherwise become lodged between the impeller and suction cover. The suction cover shall
be designed such that it may be adjusted to maintain working clearances and hydraulic efficiencies.
f. For units 71/2 to 30 HP, the impeller shall be a mixed flow multi-vane semi-open design. It shall be dynamically
balanced and shall be designed for solids handling with a long thrulet without acute turns. The inlet edge of the
impeller vanes shall be angled toward the impeller periphery so as to facilitate the release of objects that might
otherwise clog the pump. The 71/2 to 30 HP impeller design shall also include back pump out vanes to reduce the
pressure and entry of foreign materials into the mechanical seal area. In addition, a lip seal shall be located
behind the impeller hub to further reduce the entry of foreign materials into the seal area. Impellers shall be direct
connected to the motor shaft with a slip fit, key driven, and secured with an impeller bolt. The design shall include
a replaceable cast iron suction cover. The suction cover shall contain a groove(s) perpendicular to the suction opening
to disrupt fibrous solids that may otherwise become lodged between the impeller and suction cover.The suction
cover shall be designed such that it may be adjusted to maintain working clearances and hydraulic efficiencies.
2. Mechanical Seals
a. For units 2 to 5 HP, double mechanical seals operating in an oil bath shall be provided on all units. The oil filled
seal chamber shall be designed to prevent over-filling and include an anti-vortexing vane to insure proper lubrication
of both seal faces. Lower face materials shall be silicon carbide, upper faces carbon vs. ceramic, NBR elastomers,
and 304SS hardware. Seal system shall not rely on pumping medium for lubrication.
b. Units 71/2 to 60 HP shall be designed to include a double mechanical seal in a tandem arrangement. Each seal
shall be positively driven and act independently with its own spring system. The upper seal operates in an oil
bath, while the lower seal is lubricated by the oil from between the shaft and the seal faces, and in contact with
EBARA Fluid Handling
www.pumpsebara.com
(t) 803 327 5005 • (f) 803 327 5097
2-160
rev. 10/11
DLFU
EBARA Submersible Sewage Pumps
Specifications
Project:
Model:
Chk’d:
Date:
the pumpage. The oil filled seal chamber shall be designed to prevent over-filling and include an anti-vortexing
vane to insure proper lubrication of both seal faces. Lower face materials shall be silicon carbide (tungsten carbide
for 150-300 DLF 50 & 60 HP only), upper faces carbon vs. ceramic, NBR elastomers, and 304SS hardware. Seal
system shall not rely on pumping medium for lubrication.
E. Motor Construction:
The pump motor shall be an air filled induction type with a squirrel cage rotor, shell type design, built to NEMA MG-1,
Design B specifications. Stator windings shall be copper, insulated with moisture resistant Class H insulation, rated
for 356°F. The stator shall be dipped and baked three times in Class H varnish and heat shrunk fitted into the stator
housing. Rotor bars and short circuit rings shall be manufactured of cast aluminum. Motor shaft shall be one piece
AISI403 for 2 to 5 HP, AISI420 for 71/2 to 60 HP, rotating on two permanently lubricated ball bearings designed for a
minimum B-10 life of 60,000 hours. Motor service factor shall be 1.15 and capable of up to 20 starts per hour. The
motor shall be designed for continuous duty pumping at a maximum sump temperature of 104°F. Voltage and
frequency tolerances shall be a maximum 10 / 5% respectively. Motor over temperature protection shall be provided
by miniature thermal protectors embedded in the windings. Mechanical seal failure protection shall be provided by a
mechanical float switch located in a chamber above the seal. This switch shall be comprised of a magnetic float that
actuates a dry reed switch encapsulated within the stem. Should the mechanical seal fail, liquid shall be directed
into the float chamber, in which the rising liquid activates the switch opening the normally closed circuit. For units 2
to 30 HP the float body and float shall be a polypropylene material with a 316SS stopper. Units 40 HP and greater,
the float switch components shall be 304SS. The motor shall be non-overloading over the entire specified range of
operation and be able to operate at full load intermittently while unsubmerged without damage to the unit.
Power cable jacket shall be manufactured of an oil resistant chloroprene rubber material, designed for submerged
applications. Cable shall be watertight to a depth of a least 65'. The cable entry system shall comprise of primary,
secondary, and tertiary sealing methods. The primary seal shall be achieved by a cylindrical elastomeric grommet
compressed between the motor cover and a 304SS washer. Secondary sealing is accomplished with a compressed
o-ring made of NBR material. Compression and subsequent sealing shall preclude specific torque requirements. The
system shall also include tertiary sealing to prevent leakage into the motor housing due to capillary action through the
insulation if the cable is damaged or cut. The cable wires shall be cut, stripped, re-connected with a copper butt end
connector, and embedded in epoxy within the cable gland. This provides a dead end for leakage through the cable
insulation into the motor junction area. The cable entry system shall be the same for both the power and control cables.
F. Guide Rail system:
Design shall include two (2) 304SS schedule 40 guide rails sized to mount directly to the quick discharge connector,
QDC, at the floor of the wetwell and to a guide rail bracket at the top of the wetwell below the hatch opening, (refer
to project drawings). Intermediate guide brackets are recommended for rail lengths over 15 feet.
Guide rails are not part of the pump package and shall be supplied by others.
The QDC shall be manufactured of cast iron, ASTM A48 Class 30. It shall be designed to adequately support the
guide rails, discharge piping, and pumping unit under both static and dynamic loading conditions with support legs
that are suitable for anchoring it to the wetwell floor. The face of the inlet QDC flange shall be perpendicular to the
floor of the wetwell. The discharge flange of the QDC shall conform to ANSI B16.1 Class 125.
The pump design shall include an integral self-aligning sliding bracket. Sealing of the pumping unit to the QDC shall
be accomplished by a single, linear, downward motion of the pump. The entire weight of the pump unit shall be guided
to and wedged tightly against the inlet flange of the QDC, making metal to metal contact with the pump discharge
forming a seal without the use of bolts, gaskets or o-rings.
A stainless steel lifting chain of adequate length for removing and installing the pump unit is recommended. The chain
shall have a round link with a 2-1/4'' inside diameter every two feet. This link will allow for a sliding pinch bar through
the link to pick the chain, more than once if necessary, at multiple intervals during pump removal and installation.
EBARA Fluid Handling
www.pumpsebara.com
(t) 803 327 5005 • (f) 803 327 5097
2-161
rev. 10/11
DLFMU–Explosion Proof Non-clog
EBARA Submersible Sewage Pumps
Specifications
Project:
Model:
Chk’d:
Date:
A. General:
Provide FM explosion proof submersible non clog sewage pumps suitable for continuous duty operation underwater
without loss of watertight integrity to a depth of 65 feet. Pump system design shall include a guide rail system be
such that the pump will be automatically connected to the discharge piping when lowered into place on the discharge connection. The pump shall be easily removable for inspection or service, requiring no bolts, nuts, or other
fasteners to be disconnected, or the need for personnel to enter the wet well. The motor and pump shall be
designed, manufactured, and assembled by the same manufacturer.
B. Manufacturer:
EBARA International Corporation
C. Pump Characteristics:
Pumps shall conform to the following requirements:
Number of units
Design flow (gpm)
Design TDH (ft)
Minimum shut off head (ft)
RPM
Maximum HP
Minimum efficiency at design (%)
Minimum power factor at design (%)
Voltage/HZ
Phase
1800
208/230V, 460V / 60
3
D. Pump Construction:
All major parts of the pumping unit(s) including casing, impeller, suction cover, wear rings, motor frame and discharge
elbow shall be manufactured from gray cast iron, ASTM A-48 Class 30. Castings shall have smooth surfaces devoid
of blow holes or other casting irregularities. Casing design shall be centerline discharge with a large radius on the
cut water to prevent clogging. Units shall be furnished with a discharge elbow and 125 lb. flat face ANSI flange. All
exposed bolts and nuts shall be 304 stainless steel. All mating surfaces of major components shall be machined and
fitted with NBR o-rings where watertight sealing is required. Machining and fitting shall be such that sealing is
accomplished by automatic compression of o-rings in two planes and o-ring contact is made on four surfaces without
the requirement of specific torque limits. Internal and external surfaces are prepared to SPPC-VISI-SP-3-63 then coated
with a zinc-chromate primer. The external surfaces are then coated with a H.B. Teneme-Tar 46H-413 Polyamide
Epoxy - Coal Tar paint.
1. Impellers:
a. For units 2 to 5HP, the impeller shall be single or radial multi-vane, semi-open design. It shall be dynamically balanced
and shall be designed for solids handling with a long thrulet without acute turns. The inlet edge of the impeller
vanes shall be angled toward the impeller periphery so as to facilitate the release of objects that might otherwise
clog the pump. The 2 to 5 HP impeller design shall also include back pump out vanes to reduce the pressure and
entry of foreign materials into the mechanical seal area. In addition, a lip seal shall be located behind the impeller
hub to further reduce the entry of foreign materials into the seal area. Impellers shall be direct connected to the
motor shaft with a slip fit, key driven, and secured with an impeller bolt. The design shall include a replaceable
cast iron suction cover. The suction cover shall be designed such that it may be adjusted to maintain working
clearances and hydraulic efficiencies.
b. For units 71/2 to 30 HP, the impeller shall be a mixed flow multi-vane semi-open design. It shall be dynamically
balanced and shall be designed for solids handling with a long thrulet without acute turns. The inlet edge of the
impeller vanes shall be angled toward the impeller periphery so as to facilitate the release of objects that might
otherwise clog the pump. The 71/2 to 30 HP impeller design shall also include back pump out vanes to reduce the
pressure and entry of foreign materials into the mechanical seal area. In addition, a lip seal shall be located
behind the impeller hub to further reduce the entry of foreign materials into the seal area. Impellers shall be direct
EBARA Fluid Handling
www.pumpsebara.com
(t) 803 327 5005 • (f) 803 327 5097
2-162
rev. 10/11
DLFMU–Explosion Proof Non-clog
EBARA Submersible Sewage Pumps
Specifications
Project:
Model:
Chk’d:
Date:
connected to the motor shaft with a slip fit, key driven, and secured with an impeller bolt. The design shall include
a replaceable cast iron suction cover. The suction cover shall be designed such that it may be adjusted to maintain
working clearances and hydraulic efficiencies.
c. For high head units, 4'' discharge, 40 to 60 HP shall have a radial multi-vane, enclosed impeller design. It shall
be dynamically balanced and shall be designed for solids handling with a long thrulet without acute turns. The
inlet edge of the impeller vanes shall be angled toward the impeller periphery so as to facilitate the release of
objects that might otherwise clog the pump. A lip seal shall be located behind the impeller hub to reduce the entry
of foreign materials into the mechanical seal area. Impellers shall be direct connected to the motor shaft with a
slip fit, key driven, and secured with an impeller bolt. The design shall include a replaceable casing wear ring at
the pump suction to maintain working clearances and hydraulic efficiencies.
d. For units 6'' to 12'' discharge sizes, 40 to 60 HP, the impeller shall be a mixed flow multi-vane enclosed design. It
shall be dynamically balanced and shall be designed for solids handling with a long thrulet without acute turns.
The inlet edge of the impeller vanes shall be angled toward the impeller periphery so as to facilitate the release
of objects that might otherwise clog the pump. A lip seal shall be located behind the impeller hub to reduce the
entry of foreign materials into the seal area. Impellers shall be direct connected to the motor shaft with a slip fit,
key driven, and secured with an impeller bolt. The design shall include a replaceable casing wear ring at
the pump suction to maintain working clearances and hydraulic efficiencies.
optional K-series design:
e. For units 2 to 5HP, the impeller shall be single or radial multi-vane, semi-open design. It shall be dynamically balanced
and shall be designed for solids handling with a long thrulet without acute turns. The inlet edge of the impeller
vanes shall be angled toward the impeller periphery so as to facilitate the release of objects that might otherwise
clog the pump. The 2 to 5 HP impeller design shall also include back pump out vanes to reduce the pressure and
entry of foreign materials into the mechanical seal area. In addition, a lip seal shall be located behind the impeller
hub to further reduce the entry of foreign materials into the seal area. Impellers shall be direct connected to the
motor shaft with a slip fit, key driven, and secured with an impeller bolt. The design shall include a replaceable
cast iron suction cover. The suction cover shall contain a groove(s) perpendicular to the suction opening to disrupt
fibrous solids that may otherwise become lodged between the impeller and suction cover. The suction cover shall
be designed such that it may be adjusted to maintain working clearances and hydraulic efficiencies.
f. For units 71/2 to 30 HP, the impeller shall be a mixed flow multi-vane semi-open design. It shall be dynamically
balanced and shall be designed for solids handling with a long thrulet without acute turns. The inlet edge of the
impeller vanes shall be angled toward the impeller periphery so as to facilitate the release of objects that might
otherwise clog the pump. The 71/2 to 30 HP impeller design shall also include back pump out vanes to reduce the
pressure and entry of foreign materials into the mechanical seal area. In addition, a lip seal shall be located
behind the impeller hub to further reduce the entry of foreign materials into the seal area. Impellers shall be direct
connected to the motor shaft with a slip fit, key driven, and secured with an impeller bolt. The design shall include
a replaceable cast iron suction cover. The suction cover shall contain a groove(s) perpendicular to the suction opening
to disrupt fibrous solids that may otherwise become lodged between the impeller and suction cover. The suction
cover shall be designed such that it may be adjusted to maintain working clearances and hydraulic efficiencies.
2. Mechanical Seals
a. For units 2 to 5 HP, double mechanical seals operating in an oil bath shall be provided on all units. The oil filled
seal chamber shall be designed to prevent over-filling and include an anti-vortexing vane to insure proper lubrication
of both seal faces. Lower face materials shall be silicon carbide, upper faces carbon vs. ceramic, NBR elastomers,
and 304SS hardware. Seal system shall not rely on pumping medium for lubrication.
b. Units 71/2 to 60 HP shall be designed to include a double mechanical seal in a tandem arrangement. Each seal
shall be positively driven and act independently with its own spring system. The upper seal operates in an oil
bath, while the lower seal is lubricated by the oil from between the shaft and the seal faces, and in contact with
EBARA Fluid Handling
www.pumpsebara.com
(t) 803 327 5005 • (f) 803 327 5097
2-163
rev. 10/11
DLFMU–Explosion Proof Non-clog
EBARA Submersible Sewage Pumps
Specifications
Project:
Model:
Chk’d:
Date:
the pumpage. The oil filled seal chamber shall be designed to prevent over-filling and include an anti-vortexing
vane to insure proper lubrication of both seal faces. Lower face materials shall be silicon carbide (tungsten carbide
for 150-300 DLFU 50 & 60 HP only), upper faces carbon vs. ceramic, NBR elastomers, and 304SS hardware.
Seal system shall not rely on pumping medium for lubrication.
E. Motor Construction:
The pump motor shall be FM Explosion Proof, Class 1, Division 1, Groups C, D. The design shall be an air filled
induction type with a squirrel cage rotor, shell type design, built to NEMA MG-1, Design B specifications. Stator
windings shall be copper, insulated with moisture resistant Class H insulation, rated for 356°F. The stator shall be
dipped and baked three times in Class H varnish and heat shrunk fitted into the stator housing. Rotor bars and short
circuit rings shall be manufactured of cast aluminum. Motor shaft shall be one piece AISI403 material for 2 to 5 HP,
AISI420 for 71/2 to 60 HP material, rotating on two permanently lubricated ball bearings designed for a minimum B-10
life of 60,000 hours. Motor service factor shall be 1.15 and capable of up to 20 starts per hour. The motor shall be
designed for continuous duty pumping at a maximum sump temperature of 104°F. Voltage and frequency tolerances
shall be a maximum 10 / 5% respectively. Motor over temperature protection shall be provided by miniature thermal
protectors embedded in the windings. Mechanical seal failure protection shall be provided by a mechanical float
switch located in a chamber above the seal. This switch shall be comprised of a magnetic float that actuates a dry
reed switch encapsulated within the stem. Should the mechanical seal fail, liquid shall be directed into the float
chamber, in which the rising liquid activates the switch opening the normally closed circuit. For units 2 to 10 HP the
float body and float shall be a polypropylene material with a 316SS stopper. Units 15 HP and greater, the float switch
components shall be 304SS. The motor shall be non-overloading over the entire specified range of operation and be
able to operate at full load intermittently while unsubmerged without damage to the unit.
Power cable jacket shall be manufactured of an oil resistant chloroprene rubber material, designed for submerged
applications. Cable shall be watertight to a depth of a least 65'. The cable entry system shall comprise of primary,
secondary, and tertiary sealing methods. The primary seal shall be achieved by a cylindrical elastomeric grommet
compressed between the motor cover and a 304SS washer. Secondary sealing is accomplished with a compressed
o-ring made of NBR material. Compression and subsequent sealing shall preclude specific torque requirements. The
system shall also include tertiary sealing to prevent leakage into the motor housing due to capillary action through
the insulation if the cable is damaged or cut. The cable wires shall be cut, stripped, re-connected with a copper butt
end connector, and embedded in epoxy within the cable gland. This provides a dead end for leakage through the cable
insulation into the motor junction area. The cable entry system shall be the same for both the power and control cables.
F. Guide Rail system:
Design shall include two (2) 304SS schedule 40 guide rails sized to mount directly to the quick discharge connector,
QDC, at the floor of the wetwell and to a guide rail bracket at the top of the wetwell below the hatch opening, (refer
to project drawings). Intermediate guide brackets are recommended for rail lengths over 15 feet.
Guide rails are not part of the pump package and shall be supplied by others.
The QDC shall be manufactured of cast iron, ASTM A48 Class 30. It shall be designed to adequately support the
guide rails, discharge piping, and pumping unit under both static and dynamic loading conditions with support legs
that are suitable for anchoring it to the wetwell floor. The face of the inlet QDC flange shall be perpendicular to the
floor of the wetwell. The discharge flange of the QDC shall conform to ANSI B16.1 Class 125.
The pump design shall include an integral self-aligning sliding bracket. Sealing of the pumping unit to the QDC shall
be accomplished by a single, linear, downward motion of the pump. The entire weight of the pump unit shall be guided
to and wedged tightly against the inlet flange of the QDC, making metal to metal contact with the pump discharge
forming a seal without the use of bolts, gaskets or o-rings.
A stainless steel lifting chain of adequate length for removing and installing the pump unit is recommended. The chain
shall have a round link with a 2-1/4'' inside diameter every two feet. This link will allow for a sliding pinch bar through
the link to pick the chain, more than once if necessary, at multiple intervals during pump removal and installation.
EBARA Fluid Handling
www.pumpsebara.com
(t) 803 327 5005 • (f) 803 327 5097
2-164
rev. 04/11
DLFU
EBARA Submersible Sewage Pumps
Selection Chart
Project: DLFU
Model
Three Phase 60Hz
Model:
Chk’d:
m ft
300
80
60Hz (Synchronous Speed – 1800 RPM)
TOTAL HEAD
60 200
50
150
40
28
40
25 / 26
23 / 24
7
6
5
4
39
21 / 22
38
48
47
37
19 / 20
36
17 / 18
35
1
13 / 14
33
2
9 / 10
11 / 12
31
52
42
59
66
58
65
57
50
64
41
30
63
49
15
15
20
30
40 50 60
0.1
0.2
80 100
150 200
0.3 0.4 0.5 0.6
54
62
55
8
10
10
53
51
32
20
60
43
34
3
61
46
44 45
15 / 16
4
3
29
27
30 100
80
20
60
15 50
40
10
30
8
6
5
Date:
300 400 500 600 800 1000
0.8 1.0
1.5 2.0
56
1500 2000 3000 4000 USGPM
3.0 4.0 5.0 6.0
8.0 10
15 m3/min
CAPACITY
Please note: Overlap in coverage is designated by the two numbers; for example "9 / 10". Refer to the legend
below for the specific model numbers.
1 50DLFU61.5 2HP
19
2 80DLMFU61.5 2HP
37 100DLFU622 30HP
55 250DLBFU615 20HP
20 100DLMFU611 15HP
38 150DLFU630 40HP
56 250DLCFU615 20HP
3 80DLMFU62.2 3HP
21
39 150DLFU637 50HP
57 250DLFU618
25HP
4 80DLMFU63.7 5HP
22 100DLMFU615 20HP
40 150DLFU645 60HP
58 250DLFU622
30HP
5 80DLMFU65.5 7½HP
23
41 150DLFU67.5 10HP
59 250DLFU630
40HP
6 80DLCMFU67.5 10HP
24 100DLMFU618 25HP
42 150DLFU611 15HP
60 250DLFU637
50HP
7 80DLCMFU611 15HP
25
43 150DLFU615 20HP
61 250DLFU645
60HP
8 100DLFU61.5 2HP
26 100DLMFU622 30HP
44 150DLFU618 25HP
62 300DLFU618
25HP
9 80DLFU61.5 2HP
27 100DLFU630 40HP
45 150DLFU622 30HP
63 300DLFU622
30HP
10 100DLMFU61.5 2HP
28 100DLFU637 50HP
46 200DLFU630 40HP
64 300DLFU630
40HP
11
29 100DLFU645 60HP
47 200DLFU637 50HP
65 300DLFU637
50HP
12 100DLMFU62.2 3HP
30 100DLFU62.2 3HP
48 200DLFU645 60HP
66 300DLFU645
60HP
13
31 100DLFU63.7 5HP
49 200DLFU67.5 10HP
14 100DLMFU63.7 5HP
32 100DLFU65.5 7½HP
50 200DLFU611 15HP
15
33 100DLFU67.5 10HP
51 200DLFU615 20HP
16 100DLMFU65.5 7½HP
34 100DLFU611 15HP
52 200DLFU618 25HP
17
35 100DLFU615 20HP
53 200DLFU622 30HP
36 100DLFU618 25HP
54 250DLFU611 15HP
80DLFU62.2 3HP
80DLFU63.7 5HP
80DLFU65.5 7½HP
80DLFU67.5 10HP
18 100DLMFU67.5 10HP
EBARA Fluid Handling
www.pumpsebara.com
(t) 803 327 5005 • (f) 803 327 5097
80DLFU611 15HP
80DLFU615 20HP
80DLFU618 25HP
80DLFU622 30HP
2-165
rev. 03/03
DLFU
EBARA Submersible Sewage Pumps
Performance Curves
Project:
GPM:
TDH:
EFF:
HP:
50DLF61.5 (2HP) Synchronous Speed: 1800 RPM
Chk’d:
Date:
2, 3 inch Discharge
60
Curve No: DL-C603-9203
Solid Dia 1 1/2"
LM65
Max. Dia. 182mm-No Trim
60
50
Total Head (Ft)
Efficiency (%)
50
40
30
EFFICIENCY
20
30
BHP
20
10
2
10
1
0
0
0
0
20
40
60
80
100
120
Brake Horsepower (BHP)
40
140
Capacity USGPM
80DLF61.5 (2HP) Synchronous Speed: 1800 RPM
100
3, 4 inch Discharge
50
Curve No: DL-C604-9203
Solid Dia: 2 1/2"
LM80
90
6.0
5.5
5.0
80
40
4.5
70
50
40
4.0
30
3.5
3.0
EFFICIENCY
2.5
20
2.0
BHP
30
1.5
20
10
1.0
10
0
0.5
0
0
20
40
60
80
100
120
140
160
180
200
220
240
Brake Horsepower (BHP)
60
Total Head (Ft)
Efficiency (%)
Max. Dia. 170mm - No Trim
0.0
260
Capacity USGPM
EBARA Fluid Handling
www.pumpsebara.com
(t) 803 327 5005 • (f) 803 327 5097
2-166
rev. 01/02
DLFU
EBARA Submersible Sewage Pumps
Performance Curves
Project:
GPM:
TDH:
EFF:
HP:
80DLMF61.5 (2HP) Synchronous Speed: 1800 RPM
Chk’d:
Date:
3, 4 inch Discharge
50
Curve No: DLM-C601-9203
Solid Dia 3"
LM80
Max. Dia. 170mm-No Trim
50
40
30
EFFICIENCY
20
30
20
BHP
10
2
10
1
0
0
Brake Horsepower (BHP)
60
Total Head (Ft)
Efficiency (%)
40
0
0
20
40
60
80
100
120
140
160
180
200
220
240
260
Capacity USGPM
80DLF62.2 (3HP) Synchronous Speed: 1800 RPM
3, 4 inch Discharge
40
Curve No: DL-C605-9203
Solid Dia 2 1/2"
LL100
Max. Dia. 160mm
30
50
Min. Dia. 145mm
EFFICIENCY
20
40
30
10
20
BHP
3
10
2
1
0
0
Brake Horsepower (BHP)
60
Total Head (Ft)
Efficiency (%)
70
0
0
40
80
EBARA Fluid Handling
www.pumpsebara.com
(t) 803 327 5005 • (f) 803 327 5097
120
160
200
240
Capacity USGPM
280
320
360
400
2-167
rev. 01/02
DLFU
EBARA Submersible Sewage Pumps
Performance Curves
Project:
GPM:
TDH:
EFF:
HP:
Chk’d:
80DLMF62.2 (3HP) Synchronous Speed: 1800 RPM
Date:
3, 4 inch Discharge
60
Curve No: DLM-C602-9203
Solid Dia 3"
LM80
Max. Dia. 188mm - No Trim
50
Efficiency (%)
Total Head (Ft)
40
30
EFFICIENCY
40
20
BHP
30
3
20
10
2
10
1
0
0
Brake Horsepower (BHP)
50
0
0
20
40
60
80
100
120
140
160
180
200
220
240
260
Capacity USGPM
80DLF63.7 (5HP) Synchronous Speed: 1800 RPM
3, 4 inch Discharge
60
Curve No: DLM-C607-9203
Solid Dia 3"
LL100
Max. Dia. 189mm
40
60
50
40
Min. Dia. 171mm
30
EFFICIENCY
20
30
20
BHP
10
5
10
0
0
Brake Horsepower (BHP)
70
Total Head (Ft)
EFFICIENCY (%)
50
0
0
100
200
300
400
500
600
Capacity USGPM
EBARA Fluid Handling
www.pumpsebara.com
(t) 803 327 5005 • (f) 803 327 5097
2-168
rev. 01/02
DLFU
EBARA Submersible Sewage Pumps
Performance Curves
Project:
GPM:
TDH:
EFF:
HP:
Chk’d:
80DLMF63.7 (5HP) Synchronous Speed: 1800 RPM
Date:
3, 4 inch Discharge
70
Curve No: DLM-C603-9203
Solid Dia 3"
LM80
Max. Dia. 208mm
60
60
Min. Dia. 188mm
40
30
EFFICIENCY
50
40
20
30
BHP
20
10
5
10
0
0
Brake Horsepower (BHP)
70
Total Head (Ft)
Efficiency (%)
50
0
0
40
80
120
160
200
240
280
320
Capacity USGPM
80DLF65.5 (71/2HP) Synchronous Speed: 1800 RPM
3, 4 inch Discharge
70
Curve No: DLM-C608-9203
Solid Dia 3"
LL100
60
50
50
30
20
EFFICIENCY
Min. Dia. 186mm
40
30
20
8
BHP
6
10
10
4
2
0
0
0
0
100
200
300
400
500
Brake Horsepower (BHP)
40
Total Head (Ft)
EFFICIENCY (%)
Max. Dia. 207mm
60
600
Capacity USGPM
EBARA Fluid Handling
www.pumpsebara.com
(t) 803 327 5005 • (f) 803 327 5097
2-169
rev. 01/02
DLFU
EBARA Submersible Sewage Pumps
Performance Curves
Project:
GPM:
TDH:
EFF:
HP:
80DLMF65.5 (71/2HP) Synchronous Speed: 1800 RPM
Chk’d:
Date:
3, 4 inch Discharge
90
Curve No: DLM-C604-9203
Solid Dia: 3"
LM80
Max. Dia. 225mm
80
50
40
60
Min. Dia. 203mm
EFFICIENCY
50
40
30
30
20
20
10
10
0
0
8
BHP
6
4
2
Brake Horsepower (BHP)
Efficiency (%)
60
Total Head (Ft)
70
0
0
50
100
150
200
250
300
350
400
Capacity USGPM
80DLF67.5 (10HP) Synchronous Speed: 1800 RPM
3, 4 inch Discharge
80
70
70
60
60
Curve No: DLM-C609-9203
Solid Dia 3"
LL100
Max. Dia. 151.9/249mm
40
50
Min. Dia. 122.9/220mm
40
30
30
20
20
10
10
0
0
BHP
10
5
Brake Horsepower (BHP)
50
Total Head (Ft)
EFFICIENCY (%)
EFFICIENCY
0
0
100
200
300
400
500
600
700
800
Capacity USGPM
EBARA Fluid Handling
www.pumpsebara.com
(t) 803 327 5005 • (f) 803 327 5097
2-170
rev. 02/09
DLFU
EBARA Submersible Sewage Pumps
Performance Curves
Project:
GPM:
TDH:
EFF:
HP:
Chk’d:
80DLCMF67.5 (10HP) Synchronous Speed: 1800 RPM
100
3, 4 inch Discharge
100
50
Curve No: DLM-C605-9203
Solid Dia: 3"
LL80
Max. Dia. 187.5/259mm T.D.H.
90
90
80
80
70
70
Date:
45
40
Min. Dia. 165.5/237mm T.D.H.
35
60
30
50
25
40
40
20
30
30
15
20
20
10
10
10
5
0
0
50
BHP
0
100
200
300
400
Brake Horsepower (BHP)
60
Total Head (Ft)
Efficiency (%)
EFFICIENCY
0
600
500
Capacity USGPM
80DLF611 (15HP) Synchronous Speed: 1800 RPM
100
90
90
Max. Dia. 172.4/263mm
70
Min. Dia. 151.4/242mm
60
50
EFFICIENCY
40
40
30
30
20
10
20
BHP
15
10
10
5
0
0
Brake Horsepower (BHP)
Total Head (Ft)
Efficiency(%)
70
50
Curve No: DLM-C610-9203
Solid Dia 3"
LL100
80
80
60
3, 4 inch Discharge
0
0
100
200
300
400
500
600
700
800
Capacity USGPM
EBARA Fluid Handling
www.pumpsebara.com
(t) 803 327 5005 • (f) 803 327 5097
2-171
rev. 01/02
DLFU
EBARA Submersible Sewage Pumps
Performance Curves
Project:
GPM:
TDH:
EFF:
HP:
Chk’d:
80DLCMF611 (15HP) Synchronous Speed: 1800 RPM
100
90
Date:
3, 4 inch Discharge
120
Curve No: DLM-C606-9203
Solid Dia 3"
LL80
110
Max. Dia. 215/281mm
100
80
90
80
50
40
70
60
50
40
30
30
15
BHP
20
10
20
10
10
5
0
0
0
0
100
200
300
400
500
Brake Horsepower (BHP)
60
EFFICIENCY
Min. Dia. 191/257mm
Total Head (Ft)
Efficiency (%)
70
600
Capacity USGPM
80DLF615 (20HP) Synchronous Speed: 1800 RPM
3, 4 inch Discharge
120
Curve No: DLM-C611-9203
Solid Dia 3"
LL100
Max. Dia. 196.4/287mm
110
100
90
Min. Dia. 172.4/263mm
60
70
60
50
50
40
40
30
30
20
20
10
10
0
0
EFFICIENCY
BHP
0
100
200
300
400
20
15
10
5
0
500
600
700
Brake Horsepower (BHP)
70
Total Head (Ft)
Efficiency (%)
80
800
Capacity USGPM
EBARA Fluid Handling
www.pumpsebara.com
(t) 803 327 5005 • (f) 803 327 5097
2-172
rev. 01/02
DLFU
EBARA Submersible Sewage Pumps
Performance Curves
Project:
GPM:
TDH:
EFF:
HP:
80DLF618 (25HP) Synchronous Speed: 1800 RPM
Chk’d:
Date:
3, 4 inch Discharge
140
Curve No: DLM-C612-9203
Solid Dia 3"
LL100
Max. Dia. 225/307mm
120
100
60
80
60
EFFICIENCY
50
25
BHP
40
40
20
30
15
20
20
10
10
5
0
0
0
0
100
200
300
400
500
600
700
Brake Horsepower (BHP)
70
Total Head (Ft)
Efficiency (%)
Min. Dia. 199/281mm
800
Capacity USGPM
80DLF622 (30HP) Synchronous Speed: 1800 RPM
3, 4 inch Discharge
160
Curve No: DLM-C613-9203
Solid Dia 3"
LL100
Max. Dia. 238/320mm
140
Min. Dia. 211/293mm
100
70
60
80
EFFICIENCY
60
50
40
40
30
20
30
BHP
20
20
10
0
10
0
Brake Horsepower (BHP)
Total Head (Ft)
Efficiency (%)
120
0
0
100
200
300
400
500
600
700
800
Capacity USGPM
EBARA Fluid Handling
www.pumpsebara.com
(t) 803 327 5005 • (f) 803 327 5097
2-173
rev. 01/02
DLFU
EBARA Submersible Sewage Pumps
Performance Curves
Project:
GPM:
TDH:
EFF:
HP:
100DLF61.5 (2HP) Synchronous Speed: 1800 RPM
Chk’d:
Date:
3, 4 inch Discharge
30
Curve No: DL-C613-9203
Solid Dia 3"
LM80
Max. Dia. 138mm
60
EFFICIENCY
20
Min. Dia. 125mm
30
10
20
3
BHP
10
2
1
0
0
Brake Horsepower (BHP)
40
Total Head (Ft)
Efficiency (%)
50
0
0
50
100
150
200
250
300
350
Capacity USGPM
100DLF62.2 (3HP) Synchronous Speed: 1800 RPM
3, 4 inch Discharge
40
Curve No: DL-C614-9203
Solid Dia 3"
LM80
Max. Dia. 160mm
50
EFFICIENCY
Min. Dia. 145mm
20
40
30
10
20
BHP
3
10
2
1
0
0
Brake Horsepower (BHP)
60
Total Head (Ft)
Efficiency (%)
30
0
0
100
200
300
400
Capacity USGPM
EBARA Fluid Handling
www.pumpsebara.com
(t) 803 327 5005 • (f) 803 327 5097
2-174
rev. 01/02
DLFU
EBARA Submersible Sewage Pumps
Performance Curves
Project:
GPM:
TDH:
EFF:
HP:
100DLMF62.2 (3HP) Synchronous Speed: 1800 RPM
Chk’d:
Date:
3, 4 inch Discharge
40
Curve No: DL-C605-9203
Solid Dia 2 1/2"
LL100
Max. Dia. 160mm
30
Total Head (Ft)
Efficiency (%)
70
60
50
Min. Dia. 145mm
EFFICIENCY
20
Brake Horsepower (BHP)
40
30
10
20
BHP
3
10
2
1
0
0
0
0
40
80
120
160
200
240
Capacity USGPM
280
320
100DLF63.7 (5HP) Synchronous Speed: 1800 RPM
360
400
3, 4 inch Discharge
50
Curve No: DL-C615-9203
Solid Dia 3"
LM80
40
50
40
30
EFFICIENCY
Min. Dia. 156mm
20
30
20
BHP
10
0
5
4
3
2
1
0
10
0
0
50
100
150
200
250
300
350
400
450
500
550
Brake Horsepower (BHP)
60
Total Head (Ft)
Efficiency (%)
Max. Dia. 172mm
600
Capacity USGPM
EBARA Fluid Handling
www.pumpsebara.com
(t) 803 327 5005 • (f) 803 327 5097
2-175
rev. 01/02
DLFU
EBARA Submersible Sewage Pumps
Performance Curves
Project:
GPM:
TDH:
EFF:
HP:
Chk’d:
100DLMF63.7 (5HP) Synchronous Speed: 1800 RPM
Date:
3, 4 inch Discharge
60
Curve No: DLM-C607-9203
Solid Dia 3"
LL100
50
Max. Dia. 189mm
60
50
40
Min. Dia. 171mm
EFFICIENCY
30
Brake Horsepower (BHP)
70
Total Head (Ft)
Efficiency (%)
40
20
30
20
10
5
BHP
10
0
0
0
0
100
200
300
400
500
600
Capacity USGPM
100DLF65.5 (71/2HP) Synchronous Speed: 1800 RPM
100
4, 6 inch Discharge
45
90
Curve No: DLM-C614-9203
Solid Dia 3"
LL125
40
Max. Dia. 102.8/217mm
80
35
30
60
50
Total Head (Ft)
Efficiency (%)
70
Min. Dia. 89.8/204mm
25
EFFICIENCY
20
15
30
20
10
10
BHP
10
5
0
0
5
Brake Horsepower (BHP)
40
0
0
100
200
300
400
500
600
700
800
900
1000
Capacity USGPM
EBARA Fluid Handling
www.pumpsebara.com
(t) 803 327 5005 • (f) 803 327 5097
2-176
rev. 03/07
DLFU
EBARA Submersible Sewage Pumps
Performance Curves
Project:
GPM:
TDH:
EFF:
HP:
Chk’d:
100DLMF65.5 (71/2HP) Synchronous Speed: 1800 RPM
Date:
3, 4 inch Discharge
70
Curve No: DLM-C608-9203
Solid Dia 3"
LL100
Max. Dia. 207mm
60
60
50
50
40
30
20
Min. Dia. 186mm
40
30
20
Brake Horsepower (BHP)
Total Head (Ft)
Efficiency (%)
EFFICIENCY
8
BHP
6
10
10
4
2
0
0
0
0
100
200
300
400
500
600
Capacity USGPM
100DLF67.5 (10HP) Synchronous Speed: 1800 RPM
4, 6 inch Discharge
60
Curve No: DLM-C615-9203
Solid Dia 3"
LL125
100
Max. Dia. 120.8/235mm
50
90
60
50
40
Min. Dia. 103.8/218mm
EFFICIENCY
30
20
30
20
BHP
10
10
10
0
5
0
0
0
100
200
300
400
500
600
700
800
900
1000
Brake Horsepower (BHP)
70
40
Total Head (Ft)
Efficiency (%)
80
1100
Capacity USGPM
EBARA Fluid Handling
www.pumpsebara.com
2-176.1
(t) 803 327 5005 • (f) 803 327 5097
rev. 01/02
DLFU
EBARA Submersible Sewage Pumps
Performance Curves
Project:
GPM:
TDH:
EFF:
HP:
Chk’d:
100DLMF67.5 (10HP) Synchronous Speed: 1800 RPM
100
80
70
70
60
Efficiency (%)
60
50
3, 4 inch Discharge
Curve No: DLM-C609-9203
Solid Dia. 3"
LL100
Max. Dia. 151.9/249mm.
20
80
70
Min. Dia. 122.9/220mm
EFFICIENCY
60
50
50
40
40
30
30
20
20
40
30
90
10
10
0
0
BHP
0
100
200
300
400
Brake Horsepower (BHP)
80
Total Head (Ft)
90
Date:
10
500
600
700
800
0
Capacity USGPM
100DLF611 (15HP) Synchronous Speed: 1800 RPM
4, 6 inch Discharge
90
70
70
60
60
40
EFFICIENCY
Min. Dia. 120.7/235mm
50
40
30
30
20
20
10
Max. Dia. 142.8/257mm
BHP
15
10
10
5
0
0
0
100
200
300
400
500
600
700
800
900
1000
1100
0
Brake Horsepower (BHP)
50
Total Head (Ft)
Efficiency (%)
80
Curve No: DLM-C616-9203
Solid Dia 3"
LL125
Capacity USGPM
EBARA Fluid Handling
www.pumpsebara.com
(t) 803 327 5005 • (f) 803 327 5097
2-177
rev. 02/15
DLFU
EBARA Submersible Sewage Pumps
Performance Curves
Project:
GPM:
TDH:
EFF:
HP:
Chk’d:
100DLMF611 (15HP) Synchronous Speed: 1800 RPM
100
3, 4 inch Discharge
90
90
90
70
Curve No: DLM-C610-9203
Solid Dia 3"
LL100
Max. Dia. 172.4/263mm
80
80
Date:
Min. Dia. 151.4/242mm
80
70
50
60
EFFICIENCY
50
50
40
40
30
30
40
30
20
20
20
BHP
10
10
0
0
0
10
Brake Horsepower (BHP)
60
60
Total Head (Ft)
Efficiency (%)
70
0
100
200
300
400
500
600
700
800
Capacity USGPM
100DLF615 (20HP) Synchronous Speed: 1800 RPM
4, 6 inch Discharge
110
Curve No: DLM-C617-9203
Solid Dia 3"
LL125
Max. Dia. 173.1/278mm
100
90
60
50
EFFICIENCY
70
Min. Dia. 151.1/256mm
60
50
40
40
30
30
20
20
10
10
0
0
BHP
0
200
400
600
20
15
10
5
0
800
1000
Brake Horsepower (BHP)
Efficiency (%)
70
Total Head (Ft)
80
1200
Capacity USGPM
EBARA Fluid Handling
www.pumpsebara.com
(t) 803 327 5005 • (f) 803 327 5097
2-178
rev. 01/02
DLFU
EBARA Submersible Sewage Pumps
Performance Curves
Project:
GPM:
TDH:
EFF:
HP:
100DLMF615 (20HP) Synchronous Speed: 1800 RPM
Chk’d:
Date:
3, 4 inch Discharge
120
Curve No: DLM-C611-9203
Solid Dia 3"
LL100
Max. Dia. 196.4/287mm
110
100
90
Min. Dia. 172.4/263mm
60
70
60
50
50
40
40
30
30
20
20
10
10
0
0
EFFICIENCY
BHP
0
100
200
300
20
15
10
5
0
400
500
600
700
Brake Horsepower (BHP)
70
Total Head (Ft)
Efficiency (%)
80
800
Capacity USGPM
100DLMF618 (25HP) Synchronous Speed: 1800 RPM
3, 4 inch Discharge
140
Curve No: DLM-C612-9203
Solid Dia 3"
LL100
Max. Dia. 225/307mm
120
100
60
80
60
EFFICIENCY
50
40
25
40
20
BHP
30
20
15
20
10
10
0
5
0
0
0
100
200
300
400
500
600
700
Brake Horsepower (BHP)
70
Total Head (Ft)
Efficiency (%)
Min. Dia. 199/281mm
800
Capacity USGPM
EBARA Fluid Handling
www.pumpsebara.com
(t) 803 327 5005 • (f) 803 327 5097
2-179
rev. 01/02
DLFU
EBARA Submersible Sewage Pumps
Performance Curves
Project:
GPM:
TDH:
EFF:
HP:
100DLF618 (25HP) Synchronous Speed: 1800 RPM
Chk’d:
Date:
4, 6 inch Discharge
120
100
100
90
90
80
80
60
Curve No: DLM-C618-9203
Solid Dia 3"
LL125
Max. Dia. 192/288mm
Min. Dia. 168/264mm
70
60
50
50
40
40
30
30
20
20
10
10
0
0
EFFICIENCY
25
20
15
10
5
0
BHP
0
100
200
300
400
500
600
700
800
900
Brake Horsepower (BHP)
70
Total Head (Ft)
Efficiency (%)
110
1000 1100 1200
Capacity USGPM
100DLMF622 (30HP) Synchronous Speed: 1800 RPM
3, 4 inch Discharge
160
Curve No: DLM-C613-9203
Solid Dia 3"
LL100
Max. Dia. 238/320mm
140
Min. Dia. 211/293mm
100
70
60
80
EFFICIENCY
60
50
40
40
30
20
30
BHP
20
20
10
0
10
0
Brake Horsepower (BHP)
Total Head (Ft)
Efficiency (%)
120
0
0
100
200
300
400
500
600
700
800
Capacity USGPM
EBARA Fluid Handling
www.pumpsebara.com
(t) 803 327 5005 • (f) 803 327 5097
2-180
rev. 01/02
DLFU
EBARA Submersible Sewage Pumps
Performance Curves
Project:
GPM:
TDH:
EFF:
HP:
Chk’d:
100DLF622 (30HP) Synchronous Speed: 1800 RPM
Date:
4, 6 inch Discharge
140
Curve No: DLM-C619-9203
Solid Dia 3"
LL125
Max. Dia. 208/304mm
120
100
Total Head (Ft)
Efficiency (%)
90
80
70
60
Min. Dia. 183/279mm
80
60
50
EFFICIENCY
40
40
30
30
20
BHP
20
20
10
10
0
0
Brake Horsepower (BHP)
100
0
0
100
200
300
400
500
600
700
800
900
1000 1100 1200
Capacity USGPM
100DLF630 to 645 (40-60HP) Synchronous Speed: 1800 RPM
260
D = 360mm
240
D = 345mm
220
3, 4 inch Discharge
Curve No: DL-C601-9608
Solid Dia 3"
LL100
50
60
65
D = 330mm
68
200
D = 315mm
Total Head (Ft)
70
180
D = 300mm
160
70
140
120
40 HP
100
60 HP
80
50 HP
60
40
0
200
400
600
800
1000
1200
1400
1600
1800
Capacity USGPM
EBARA Fluid Handling
www.pumpsebara.com
2-180.1
(t) 803 327 5005 • (f) 803 327 5097
rev. 01/02
DLFU
EBARA Submersible Sewage Pumps
Performance Curves
Project:
GPM:
TDH:
EFF:
HP:
150DLF67.5 200DLF67.5 (10HP) Synchronous Speed: 1800 RPM
Chk’d:
Date:
6, 8 inch Discharge
60
Curve No: DL-C622-9203
Solid Dia 3"
LL150
50
Max. Dia. 124.6/225mm
60
50
Total Head (Ft)
Efficiency (%)
70
40
EFFICIENCY
Min. Dia. 107.6/208mm
30
20
30
BHP
20
10
10
10
5
0
Brake Horsepower (BHP)
40
0
0
0
200
400
600
800
1000
1200
1400
Capacity USGPM
150DLF611 200DLF611 (15HP) Synchronous Speed: 1800 RPM
6, 8 inch Discharge
80
70
Curve No: DL-C623-9203
Solid Dia 3"
LL150
70
Max. Dia. 143.6/244mm
EFFICIENCY
40
50
40
Min. Dia. 125.6/226mm
30
30
20
20
BHP
15
10
10
10
5
0
0
0
200
400
600
800
1000
1200
1400
Brake Horsepower (BHP)
50
60
Total Head (Ft)
Efficiency (%)
60
0
1600
Capacity USGPM
EBARA Fluid Handling
www.pumpsebara.com
(t) 803 327 5005 • (f) 803 327 5097
2-181
rev. 01/02
DLFU
EBARA Submersible Sewage Pumps
Performance Curves
Project:
GPM:
TDH:
EFF:
HP:
150DLF615 200DLF615 (20HP) Synchronous Speed: 1800 RPM
Chk’d:
Date:
6, 8 inch Discharge
100
Curve No: DL-C624-9203
Solid Dia 3"
LL150
Max. Dia. 180/268mm
90
80
50
EFFICIENCY
60
Min. Dia. 152/240mm
50
40
40
30
30
20
20
10
10
0
0
BHP
20
10
0
200
400
600
800
1000
1200
1400
Brake Horsepower (BHP)
60
70
Total Head (Ft)
Efficiency (%)
70
0
1600
Capacity USGPM
150DLF618 200DLF618 (25HP) Synchronous Speed: 1800 RPM
110
100
6, 8 inch Discharge
Curve No: DL-C625-9203
Solid Dia 3"
LL150
Max. Dia. 186/274mm
90
60
50
EFFICIENCY
70
Min. Dia. 163/251mm
60
50
40
40
30
30
20
20
10
10
0
0
BHP
0
200
400
600
800
25
20
15
10
5
0
1000
1200
1400
Brake Horsepower (BHP)
Efficiency (%)
70
Total Head (Ft)
80
1600
Capacity USGPM
EBARA Fluid Handling
www.pumpsebara.com
2-181.1
(t) 803 327 5005 • (f) 803 327 5097
rev. 01/02
DLFU
EBARA Submersible Sewage Pumps
Performance Curves
Project:
GPM:
TDH:
EFF:
HP:
150DLF622 200DLF622 (30HP) Synchronous Speed: 1800 RPM
Chk’d:
Date:
6,8 inch Discharge
110
Curve No: DL-C626-9203
Solid Dia 3"
LL150
100
Max. Dia. 192/296mm
90
60
50
EFFICIENCY
70
Min. Dia. 168/272mm
60
50
40
40
30
30
20
20
20
10
10
10
0
0
BHP
Brake Horsepower (BHP)
Efficiency (%)
70
Total Head (Ft)
80
30
0
0
200
400
600
800
1000
1200
1400
1600
Capacity USGPM
150DLF630 (40HP) Synchronous Speed: 1800 RPM
6 inch Discharge
140
Curve No: DLY-C601-9203
Solid Dia 3"
LL150Y
Max. Dia. 204/310mm
120
70
60
Min. Dia. 178/284mm
80
EFFICIENCY
60
50
40
40
40
BHP
30
20
30
20
20
10
0
Brake Horsepower (BHP)
80
Total Head (Ft)
Efficiency (%)
100
10
0
0
200
400
600
800
1000
1200
1400
1600
1800
0
2000
Capacity USGPM
EBARA Fluid Handling
www.pumpsebara.com
(t) 803 327 5005 • (f) 803 327 5097
2-182
rev. 02/15
DLFU
EBARA Submersible Sewage Pumps
Performance Curves
Project:
GPM:
TDH:
EFF:
HP:
150DLF637 (50HP) Synchronous Speed: 1800 RPM
Chk’d:
Date:
6 inch Discharge
160
Curve No: DLY-C602-9203
Solid Dia 3"
LL150Y
Max. Dia. 226/324mm
140
120
Min. Dia. 199/297mm
60
80
EFFICIENCY
60
50
50
BHP
40
40
40
30
30
20
20
20
10
10
0
0
0
200
400
600
800
1000
1200
1400
1600
1800
0
2000
Brake Horsepower (BHP)
70
Total Head (Ft)
Efficiency (%)
100
Capacity USGPM
150DLF645 (60HP) Synchronous Speed: 1800 RPM
6 inch Discharge
200
180
80
160
70
140
Curve No: DLY-C603-9203
Solid Dia 3"
LL150Y
Max. Dia. 255/353mm
50
120
Min. Dia. 225/323mm
100
40
80
30
60
20
40
10
20
0
0
60
BHP
50
40
30
20
0
200
400
600
800
1000
1200
1400
1600
Brake Horsepower (BHP)
60
Total Head (Ft)
Efficiency (%)
EFFICIENCY
1800
Capacity USGPM
EBARA Fluid Handling
www.pumpsebara.com
(t) 803 327 5005 • (f) 803 327 5097
2-183
rev. 01/02
DLFU
EBARA Submersible Sewage Pumps
Performance Curves
Project:
GPM:
TDH:
EFF:
HP:
Chk’d:
200DLF630 (40HP) Synchronous Speed: 1800 RPM
Date:
8 inch Discharge
120
110
Curve No: DLY-C604-9203
Solid Dia 3"
LL200Y
Max. Dia. 220/307mm
100
80
60
70
60
50
50
40
40
30
30
20
20
10
10
0
0
EFFICIENCY
BHP
40
30
20
10
0
0
200
400
600
800
1000
1200
1400
1600
1800
2000
Brake Horsepower (BHP)
70
Min. Dia. 194/281mm
Total Head (Ft)
Efficiency (%)
90
2200
Capacity USGPM
200DLF637 (50HP) Synchronous Speed: 1800 RPM
8 inch Discharge
160
140
Curve No: DLY-C605-9203
Solid Dia 3"
LL200Y
Max. Dia. 241/328mm
100
60
Min. Dia. 217/304mm
80
EFFICIENCY
60
50
40
BHP
40
50
30
20
40
30
20
10
0
20
0
0
200
400
600
800
1000
1200
1400
1600
1800
2000
2200
10
Brake Horsepower (BHP)
70
Total Head (Ft)
Efficiency (%)
120
Capacity USGPM
EBARA Fluid Handling
www.pumpsebara.com
(t) 803 327 5005 • (f) 803 327 5097
2-184
rev. 02/15
DLFU
EBARA Submersible Sewage Pumps
Performance Curves
Project:
GPM:
TDH:
EFF:
HP:
Chk’d:
200DLF645 (60HP) Synchronous Speed: 1800 RPM
Date:
8 inch Discharge
180
Curve No: DLY-C606-9203
Solid Dia 3"
LL200Y
160
Max. Dia. 263/350mm
60
EFFICIENCY
120
Min. Dia. 232/319mm
100
50
80
40
60
60
BHP
50
30
40
40
30
20
20
20
0
200
400
600
800
Brake Horsepower (BHP)
70
140
Total Head (Ft)
Efficiency (%)
80
1000 1200 1400 1600 1800 2000 2200 2400
Capacity USGPM
250DLF611 (15HP) Synchronous Speed: 1800 RPM
100
10 inch Discharge
60
Curve No: DL-C627-9203
Solid Dia 3 1/4"
LL250
90
Max. Dia. 143.1/243mm
50
80
60
50
Total Head (Ft)
EFFICIENCY (%)
70
EFFICIENCY
40
Min. Dia. 130.1/230mm
30
20
30
BHP
15
20
10
10
10
0
5
0
0
0
200
400
600
800
1000
1200
1400
1600
1800
Brake Horsepower (BHP)
40
2000
Capacity USGPM
EBARA Fluid Handling
www.pumpsebara.com
(t) 803 327 5005 • (f) 803 327 5097
2-185
rev. 03/07
DLFU
EBARA Submersible Sewage Pumps
Performance Curves
Project:
GPM:
TDH:
EFF:
HP:
Chk’d:
250DLBF615 (20HP) Synchronous Speed: 1800 RPM
Date:
10 inch Discharge
70
Curve No: DL-C628-9203
Solid Dia 3 1/4"
LL250
60
Max. Dia. 158.1/258mm
60
40
EFFICIENCY
Min. Dia. 138.1/238mm
30
50
40
20
30
BHP
20
20
10
10
10
0
0
0
0
200
400
600
800
1000
1200
1400
1600
1800
2000
Brake Horsepower (BHP)
70
Total Head (Ft)
EFFICIENCY (%)
50
2200
Capacity USGPM
250DLCF615 (20HP) Synchronous Speed: 1800 RPM
10 inch Discharge
80
Curve No: DL-C629-9203
Solid Dia 3 1/4"
LL250
70
Max. Dia. 171/265mm
60
50
Min. Dia. 151/245mm
40
EFFICIENCY
30
50
40
20
30
20
25
BHP
10
20
10
0
15
0
0
200
400
600
800
1000
1200
1400
1600
1800
2000
2200
10
Brake Horsepower (BHP)
70
Total Head (Ft)
EFFICIENCY (%)
60
Capacity USGPM
EBARA Fluid Handling
www.pumpsebara.com
(t) 803 327 5005 • (f) 803 327 5097
2-186
rev. 02/15
DLFU
EBARA Submersible Sewage Pumps
Performance Curves
Project:
GPM:
TDH:
EFF:
HP:
Chk’d:
250DLF618 (25HP) Synchronous Speed: 1800 RPM
Date:
10 inch Discharge
90
70
70
60
60
40
Max. Dia. 179/273mm
EFFICIENCY
50
Min. Dia. 157/251mm
40
30
30
20
20
10
10
0
0
BHP
25
20
15
10
5
0
400
800
1200
1600
Brake Horsepower (BHP)
50
Total Head (Ft)
EFFICIENCY (%)
80
Curve No: DL-C630-9203
Solid Dia 3 1/4"
LL250
0
2400
2000
Capacity USGPM
250DLF622 (30HP) Synchronous Speed: 1800 RPM
10 inch Discharge
100
80
70
70
50
EFFICIENCY
60
Min. Dia. 169/263mm
50
40
40
30
30
20
20
20
10
10
10
0
0
BHP
0
400
800
30
1200
1600
2000
0
Brake Horsepower (BHP)
60
Total Head (Ft)
EFFICIENCY (%)
80
Curve No: DL-C631-9203
Solid Dia 3 1/4"
LL250
Max. Dia. 187/281mm
90
2400
Capacity USGPM
EBARA Fluid Handling
www.pumpsebara.com
(t) 803 327 5005 • (f) 803 327 5097
2-187
rev. 02/15
DLFU
EBARA Submersible Sewage Pumps
Performance Curves
Project:
GPM:
TDH:
EFF:
HP:
Chk’d:
250DLF630 (40HP) Synchronous Speed: 1800 RPM
100
Max. Dia. 216/306mm
70
70
50
EFFICIENCY
Min. Dia. 190/280mm
60
50
40
40
30
30
20
20
10
10
0
0
BHP
40
30
20
10
0
300
600
900
1200
1500
1800
2100
2400
2700
0
3000
Brake Horsepower (BHP)
60
Total Head (Ft)
EFFICIENCY (%)
80
10 inch Discharge
Curve No: DLY-C607-9203
Solid Dia 3"
LL250Y
90
80
Date:
Capacity USGPM
250DLF637 (50HP) Synchronous Speed: 1800 RPM
10 inch Discharge
140
Max. Dia. 231/321mm
Curve No: DLY-C608-9203
Solid Dia 3"
LL250Y
120
60
Min. Dia. 203/293mm
80
EFFICIENCY
60
BHP
50
40
50
40
40
30
20
30
20
20
10
0
10
0
0
0
500
1000
1500
2000
2500
Brake Horsepower (BHP)
70
Total Head (Ft)
EFFICIENCY (%)
100
3000
Capacity USGPM
EBARA Fluid Handling
www.pumpsebara.com
(t) 803 327 5005 • (f) 803 327 5097
2-188
rev. 02/15
DLFU
EBARA Submersible Sewage Pumps
Performance Curves
Project:
GPM:
TDH:
EFF:
HP:
250DLF645 (60HP) Synchronous Speed: 1800 RPM
Chk’d:
Date:
10 inch Discharge
140
Curve No: DLY-C609-9203
Solid Dia 3"
LL250Y
Max. Dia. 248/338mm
120
70
60
Min. Dia. 219/309mm
80
EFFICIENCY
60
50
40
40
BHP
30
20
60
40
20
10
20
0
0
0
0
500
1000
1500
2000
2500
3000
Brake Horsepower (BHP)
80
Total Head (Ft)
EFFICIENCY (%)
100
3500
Capacity USGPM
300DLF618 (25HP) Synchronous Speed: 1800 RPM
12 inch Discharge
50
Curve No: DL-C632-9203
Solid Dia 3 1/2"
LL300
Max. Dia. 137.1/237mm
50
40
30
EFFICIENCY
Min. Dia. 120.1/220mm
20
30
20
BHP
25
20
10
15
10
10
5
0
0
0
0
1000
2000
Brake Horsepower (BHP)
60
Total Head (Ft)
EFFICIENCY (%)
40
3000
Capacity USGPM
EBARA Fluid Handling
www.pumpsebara.com
(t) 803 327 5005 • (f) 803 327 5097
2-189
rev. 01/02
DLFU
EBARA Submersible Sewage Pumps
Performance Curves
Project:
GPM:
TDH:
EFF:
HP:
300DLF622 (30HP) Synchronous Speed: 1800 RPM
Chk’d:
Date:
12 inch Discharge
50
Max. Dia. 151.1/251mm
Curve No: DL-C633-9203
Solid Dia 3 1/2"
LL300
50
40
30
EFFICIENCY
Min. Dia. 131.1/231mm
20
30
20
10
30
BHP
10
20
0
Brake Horsepower (BHP)
60
Total Head (Ft)
Efficiency (%)
40
10
0
0
1000
2000
3000
Capacity USGPM
300DLF630 (40HP) Synchronous Speed: 1800 RPM
12 inch Discharge
60
Curve No: DLY-C610-9203
Solid Dia 3"
LL300Y
Max. Dia. 155.6/274mm
70
60
Total Head (Ft)
Efficiency (%)
50
40
Min. Dia. 134.6/253mm
EFFICIENCY
30
40
20
BHP
30
20
40
10
30
10
0
20
0
Brake Horsepower (BHP)
50
10
0
1000
2000
3000
4000
Capacity USGPM
EBARA Fluid Handling
www.pumpsebara.com
(t) 803 327 5005 • (f) 803 327 5097
2-190
rev. 01/02
DLFU
EBARA Submersible Sewage Pumps
Performance Curves
Project:
GPM:
TDH:
EFF:
HP:
300DLF637 (50HP) Synchronous Speed: 1800 RPM
Chk’d:
Date:
12 inch Discharge
80
Curve No: DLY-C611-9203
Solid Dia 3"
LL300Y
Max. Dia. 174/278mm
70
70
60
50
Min. Dia. 151/255mm
40
30
EFFICIENCY
50
40
BHP
20
50
30
40
20
30
10
10
20
0
10
0
0
600
1200
1800
2400
3000
3600
Brake Horsepower (BHP)
80
Total Head (Ft)
EFFICIENCY (%)
60
4200
Capacity USGPM
300DLF645 (60HP) Synchronous Speed: 1800 RPM
12 inch Discharge
100
90
80
80
70
70
Curve No: DLY-C612-9203
Solid Dia 3"
LL300Y
Max. Dia. 191/295mm
50
60
Min. Dia. 167/271mm
50
40
40
30
30
20
20
10
10
0
0
BHP
60
50
40
30
Brake Horsepower (BHP)
60
Total Head (Ft)
EFFICIENCY (%)
EFFICIENCY
20
0
1000
2000
3000
4000
5000
Capacity USGPM
EBARA Fluid Handling
www.pumpsebara.com
2-190.1
(t) 803 327 5005 • (f) 803 327 5097
rev. 01/02
DLFU
EBARA Submersible Sewage Pumps
Dimensions
Project:
Model:
Chk’d:
Date:
Model DLFU
50DLFU, 2HP
80DLFU, 2 to 30HP
t
f
e
ø
(n) QTY - (h) HOLES
Flange (ANSI 125 PSI F.F)
Dimensions: inch
PHASE SIZE
MODEL
ø
2/3 50DLFU61.5
80DLFU61.5
80DLFU62.2
80DLFU63.7
80DLFU65.5
THREE 3/4 80DLFU67.5
80DLFU611
80DLFU615
80DLFU618
80DLFU622
ø
2
3
4
e
43/4
6
71/2
f
6
71/2
9
t
5
/8
3
/4
15
/16
n
4
4
8
inch
h
3
/4
3
/4
3
/4
ø
50
80
100
e
121
152
191
f
152
191
229
t
16
19
24
n
4
4
8
mm
h
19
19
19
OUTPUT
kW
HP
1.5
2
1.5
2
2.2
3
3.7
5
5.5
71/2
7.5
10
11
15
15
20
18.5
25
22
30
A
1711/16
203/4
2313/16
2313/16
2313/16
251/16
261/8
261/8
271/4
271/4
B
101/8
111/2
133/16
133/16
133/16
141/2
153/16
153/16
1513/16
1513/16
C
125/8
15
173/16
173/16
173/16
173/4
189/16
189/16
195/16
195/16
D
51/16
53/4
65/8
65/8
65/8
75/16
75/8
75/8
715/16
715/16
PUMP & MOTOR
F
E
77/8
95/8
811/16
111/4
3
913/16
13 /8
913/16
133/8
3
913/16
13 /8
1211/16
14
1211/16
143/4
1211/16
143/4
9
15 /16 1211/16
159/16 1211/16
G
5
/16
5
/16
5
/16
5
/16
3
/8
3
/8
5
/16
5
/16
5
/16
5
/16
H
2711/16
281/2
301/4
3113/16
371/8
361/16
399/16
425/16
437/8
437/8
J
71/16
81/4
91/4
91/4
91/4
913/16
105/8
105/8
117/16
117/16
L
65/16
71/16
81/16
81/16
11
101/4
913/16
1013/16
1013/16
1013/16
WEIGHT
Lb
132
148
209
209
317
344
470
564
639
694
OUTPUT
kW
HP
1.5
2
1.5
2
2.2
3
3.7
5
5.5
71/2
7.5
10
11
15
15
20
18.5
25
22
30
A
450
527
605
605
605
636
664
664
692
692
B
257
292
335
335
335
369
385
385
402
402
C
321
381
436
436
436
451
471
471
491
491
D
129
146
169
169
169
186
193
193
202
202
PUMP & MOTOR
E
F
245
200
285
220
340
250
340
250
340
250
355
323
375
323
375
323
395
323
395
323
G
8
8
8
8
10
10
8
8
8
8
H
703
724
768
808
943
916
1005
1075
1115
1115
J
180
210
235
235
235
250
270
270
290
290
L
160
180
205
205
280
260
250
275
275
275
WEIGHT
kg
60
67
95
95
144
156
213
256
290
315
Dimensions: mm
MODEL
PHASE SIZE
ø
50/80 50DLFU61.5
80DLFU61.5
80DLFU62.2
80DLFU63.7
80DLFU65.5
THREE 80/100 80DLFU67.5
80DLFU611
80DLFU615
80DLFU618
80DLFU622
*Note: All 80DLFU dimensions are based on 3'' discharge.
EBARA Fluid Handling
www.pumpsebara.com
(t) 803 327 5005 • (f) 803 327 5097
2-191
rev. 01/02
DLFU
EBARA Submersible Sewage Pumps
Dimensions
Project:
Model:
Chk’d:
Date:
Model DLMFU
80DLMFU, 2 to 71/2HP
80DLCMFU, 10 to 15HP
t
f
e
ø
(n) QTY - (h) HOLES
Flange (ANSI 125 PSI F.F)
ø
3
4
e
6
71/2
f
71/2
9
t
3
/4
15
/16
n
4
8
inch
h
3
/4
3
/4
ø
80
100
e
152
191
f
191
229
t
19
24
n
4
8
mm
h
19
19
Dimensions: inch
PHASE SIZE
ø
THREE
MODEL
80DLMFU61.5
80DLMFU62.2
80DLMFU63.7
3/4
80DLMFU65.5
80DLCMFU67.5
80DLCMFU611
HP
2
3
5
71/2
10
15
A
203/4
203/4
217/16
227/16
263/8
279/16
B
111/2
111/2
121/8
1215/16
1415/16
1511/16
C
15
15
153/8
16
187/8
1911/16
D
53/4
53/4
61/16
67/16
71/2
77/8
PUMP & MOTOR
E
F
111/4
811/16
111/4
811/16
115/8
811/16
3
12 /16
811/16
133/16
121/16
14
12
G
/16
5
/16
5
/16
3
/8
3
/8
5
/16
H
281/2
291/2
311/16
363/8
355/8
395/16
J
81/4
81/4
811/16
91/4
101/4
11
L
7 /16
71/2
71/2
101/4
97/16
97/16
WEIGHT
Lb
157
187
205
311
375
500
OUTPUT
kW
HP
1.5
2
2.2
3
3.7
5
5.5
71/2
7.5
10
11
15
A
527
527
545
570
670
700
B
292
292
308
328
379
399
C
381
381
391
406
480
500
D
146
146
154
164
190
200
PUMP & MOTOR
E
F
285
220
285
220
295
220
310
220
335
307
355
305
G
8
8
8
10
10
8
H
724
750
789
924
905
998
J
210
210
220
235
260
280
L
180
190
190
261
240
240
WEIGHT
kg
71
85
93
141
170
227
OUTPUT
kW
1.5
2.2
3.7
5.5
7.5
11
5
1
Dimensions: mm
PHASE SIZE
ø
MODEL
80DLMFU61.5
80DLMFU62.2
80DLMFU63.7
THREE 80/100
80DLMFU65.5
80DLCMFU67.5
80DLCMFU611
*Note: All dimensions are based on 3'' discharge.
EBARA Fluid Handling
www.pumpsebara.com
(t) 803 327 5005 • (f) 803 327 5097
2-192
rev. 01/02
DLFU
EBARA Submersible Sewage Pumps
Dimensions
Project:
Model:
Chk’d:
Date:
Model DLFU
100DLFU, 2 to 60HP
t
f
e
ø
(n) QTY - (h) HOLES
Flange (ANSI 125 PSI F.F)
ø
3
4
6
e
6
71/2
91/2
f
71/2
9
11
t
3
/4
15
/16
1
n
4
8
8
ø
80
100
150
e
152
191
241
f
191
229
279
t
19
24
25
n
4
8
8
inch
h
3
/4
3
/4
7
/8
mm
h
19
19
22
Dimensions: inch
PHASE SIZE
MODEL
ø
3/4 100DLFU61.5
100DLFU62.2
100DLFU63.7
100DLFU65.5
100DLFU67.5
4/6 100DLFU611
THREE
100DLFU615
100DLFU618
100DLFU622
4 100DLFU630
100DLFU637
100DLFU645
OUTPUT
kW
HP
1.5
2
2.2
3
3.7
5
5.5
71/2
7.5
10
11
15
15
20
18.5
25
22
30
30
40
37
50
45
60
A
213/4
227/8
227/8
289/16
289/16
289/16
293/4
307/8
307/8
331/4
331/4
331/4
B
101/2
111/8
111/8
1511/16
1511/16
1511/16
167/16
171/4
171/4
199/16
199/16
199/16
C
169/16
175/16
175/16
2011/16
2011/16
2011/16
217/16
221/4
221/4
235/8
235/8
235/8
D
51/4
59/16
59/16
77/8
77/8
77/8
81/4
811/16
811/16
95/8
95/8
95/8
PUMP & MOTOR
E
F
12
1013/16
1213/16 1013/16
1213/16 1013/16
161/8
15
161/8
15
161/8
15
1615/16 1413/16
1711/16 1413/16
1711/16 1413/16
191/8
197/16
191/8
197/16
1
8
19 /
197/16
G
5
/16
5
/16
5
/16
3
/8
3
/8
5
/16
5
/16
5
/16
5
/16
5
/16
5
/16
5
/16
H
2915/16
3013/16
323/8
377/16
377/16
411/8
431/4
4413/16
4413/16
553/4
595/16
595/16
J
77/8
811/16
811/16
11
11
11
1113/16
125/8
125/8
143/16
143/16
143/16
L
811/16
811/16
811/16
117/16
117/16
117/16
1113/16
1113/16
1113/16
195/16
205/16
205/16
WEIGHT
Lb
170
198
216
353
395
476
602
677
736
1001
1171
1219
OUTPUT
kW
HP
1.5
2
2.2
3
3.7
5
5.5
71/2
7.5
10
11
15
15
20
18.5
25
22
30
30
40
37
50
45
60
A
553
581
581
725
725
725
755
784
784
845
845
845
B
267
282
282
398
398
398
417
438
438
497
497
497
C
420
440
440
525
525
525
545
565
565
600
600
600
D
134
141
141
200
200
200
210
220
220
245
245
245
PUMP & MOTOR
E
F
305
275
325
275
325
275
410
381
410
381
410
381
430
377
450
377
450
377
485
493
485
493
485
493
G
8
8
8
10
10
8
8
8
8
8
8
8
H
760
782
822
951
951
1044
1099
1139
1139
1416
1506
1506
J
200
220
220
280
280
280
300
320
320
360
360
360
L
220
220
220
290
290
290
300
300
300
490
516
516
WEIGHT
kg
77
90
98
160
179
216
273
307
334
454
531
553
Dimensions: mm
PHASE SIZE
ø
MODEL
100DLFU61.5
100DLFU62.2
100DLFU63.7
100DLFU65.5
100DLFU67.5
100DLFU611
THREE 100/150
100DLFU615
100DLFU618
100DLFU622
100 100DLFU630
100DLFU637
100DLFU645
80/100
*Note: All dimensions are based on 4'' discharge.
EBARA Fluid Handling
www.pumpsebara.com
(t) 803 327 5005 • (f) 803 327 5097
2-193
rev. 11/02
DLFU
EBARA Submersible Sewage Pumps
Dimensions
Project:
Model:
Chk’d:
Date:
Model DLMFU
100DLMFU, 3 to 30HP
t
f
e
ø
(n) QTY - (h) HOLES
Flange (ANSI 125 PSI F.F)
ø
3
4
e
6
71/2
f
71/2
9
t
3
/4
15
/16
n
4
8
inch
h
3
/4
3
/4
ø
80
100
e
152
191
f
191
229
t
19
24
n
4
8
mm
h
19
19
Dimensions: inch
PHASE SIZE
ø
THREE
MODEL
100DLMFU62.2
100DLMFU63.7
100DLMFU65.5
100DLMFU67.5
3/4
100DLMFU611
100DLMFU615
100DLMFU618
100DLMFU622
OUTPUT
kW
HP
2.2
3
3.7
5
5.5
71/2
7.5
10
11
15
15
20
18.5
25
22
30
A
249/16
249/16
249/16
2513/16
267/8
267/8
28
28
B
133/16
133/16
133/16
141/2
153/16
153/16
1513/16
1513/16
C
1715/16
1715/16
1715/16
181/2
181/2
181/2
201/16
201/16
D
65/8
65/8
65/8
75/16
75/8
75/8
715/16
715/16
PUMP & MOTOR
E
F
133/8
913/16
133/8
913/16
3
13 /8
913/16
14
1211/16
143/4
1211/16
143/4
1211/16
9
15 /16 1211/16
159/16 1211/16
G
5
/16
5
/16
3
/8
3
/8
5
/16
5
/16
5
/16
5
/16
H
301/4
3113/16
371/8
361/16
399/16
425/16
437/8
437/8
J
91/4
91/4
91/4
913/16
105/8
105/8
117/16
117/16
L
81/16
81/16
11
101/4
913/16
1013/16
1013/16
1013/16
WEIGHT
Lb
209
209
317
344
470
564
639
694
OUTPUT
kW
HP
2.2
3
3.7
5
5.5
71/2
7.5
10
11
15
15
20
18.5
25
22
30
A
624
624
624
655
683
683
711
711
B
335
335
335
369
385
385
402
402
C
455
455
455
470
470
470
510
510
D
169
169
169
186
193
193
202
202
PUMP & MOTOR
E
F
340
250
340
250
340
250
355
323
375
323
375
323
395
323
395
323
G
8
8
10
10
8
8
8
8
H
768
808
943
916
1005
1075
1115
1115
J
235
235
235
250
270
270
290
290
L
205
205
280
260
250
275
275
275
WEIGHT
kg
95
95
144
156
213
256
290
315
Dimensions: mm
PHASE SIZE
ø
MODEL
100DLMFU62.2
100DLMFU63.7
100DLMFU65.5
100DLMFU67.5
THREE 80/100
100DLMFU611
100DLMFU615
100DLMFU618
100DLMFU622
*Note: All dimensions are based on 4'' discharge.
EBARA Fluid Handling
www.pumpsebara.com
2-193.1
(t) 803 327 5005 • (f) 803 327 5097
rev. 01/02
DLFU
EBARA Submersible Sewage Pumps
Dimensions
Project:
Model:
Chk’d:
Date:
Model DLFU
150DLFU, 10 to 60HP
t
f
e
ø
(n) QTY - (h) HOLES
Flange (ANSI 125 PSI F.F)
ø
6
8
e
91/2
113/4
f
11
131/2
t
1
11/8
n
8
8
inch
h
7
/8
7
/8
ø
150
200
e
241
298
f
279
343
t
25
29
n
8
8
mm
h
22
22
Dimensions: inch
PHASE SIZE
ø
THREE
MODEL
150DLFU67.5
150DLFU611
150DLFU615
150DLFU618
6/8
150DLFU622
150DLFU630
150DLFU637
150DLFU645
OUTPUT
kW
HP
7.5
10
11
15
15
20
18.5
25
22
30
30
40
37
50
45
60
A
313/4
313/4
33
33
341/4
321/2
321/2
321/2
B
1615/16
1615/16
1713/16
1713/16
187/8
189/16
189/16
189/16
C
231/4
231/4
24
24
2413/16
231/4
231/4
231/4
D
89/16
89/16
9
9
91/2
95/16
95/16
95/16
PUMP & MOTOR
E
F
1711/16 165/16
1711/16 165/16
181/2
161/8
1
18 /2
161/8
195/16
163/16
173/4
237/8
173/4
237/8
3
17 /4
237/8
G
/8
5
/16
5
/16
5
/16
5
/16
5
/16
5
/16
5
/16
H
381/2
423/16
441/4
4513/16
453/4
529/16
557/8
557/8
J
1113/16
1113/16
125/8
125/8
133/8
133/4
133/4
133/4
L
123/8
123/8
125/8
125/8
125/8
161/8
1615/16
1615/16
WEIGHT
Lb
428
549
635
712
787
1294
1345
1404
OUTPUT
kW
HP
7.5
10
11
15
15
20
18.5
25
22
30
30
40
37
50
45
60
A
806
806
838
838
870
826
826
826
B
430
430
453
453
479
471
471
471
C
590
590
610
610
630
590
590
590
D
217
217
228
228
241
236
236
236
PUMP & MOTOR
E
F
450
414
450
414
470
410
470
410
490
411
451
607
451
607
451
607
G
10
8
8
8
8
8
8
8
H
978
1071
1124
1164
1162
1335
1420
1420
J
300
300
320
320
340
350
350
350
L
315
315
320
320
320
409
430
430
WEIGHT
kg
194
249
288
323
357
587
610
637
3
Dimensions: mm
PHASE SIZE
ø
MODEL
150DLFU67.5
150DLFU611
150DLFU615
150DLFU618
THREE 150/200
150DLFU622
150DLFU630
150DLFU637
150DLFU645
EBARA Fluid Handling
www.pumpsebara.com
(t) 803 327 5005 • (f) 803 327 5097
2-194
rev. 01/02
DLFU
EBARA Submersible Sewage Pumps
Dimensions
Project:
Model:
Chk’d:
Date:
Model DLFU
200DLFU, 10 to 60HP
t
f
e
ø
(n) QTY - (h) HOLES
Flange (ANSI 125 PSI F.F)
ø
6
8
e
91/2
113/4
f
11
131/2
t
1
11/8
n
8
8
inch
h
7
/8
7
/8
ø
150
200
e
241
298
f
279
343
t
25
29
n
8
8
mm
h
22
22
Dimensions: inch
PHASE SIZE
ø
THREE
MODEL
200DLFU67.5
200DLFU611
200DLFU615
200DLFU618
6/8
200DLFU622
200DLFU630
200DLFU637
200DLFU645
OUTPUT
kW
HP
7.5
10
11
15
15
20
18.5
25
22
30
30
40
37
50
45
60
A
33
337/16
341/4
343/4
349/16
353/16
353/16
353/16
B
1615/16
1615/16
1713/16
1713/16
187/8
209/16
209/16
209/16
C
241/2
241/2
251/4
251/4
261/16
247/8
247/8
247/8
D
89/16
9
9
91/2
89/16
105/16
105/16
105/16
PUMP & MOTOR
E
F
1711/16 165/16
1711/16 165/16
181/2
161/8
181/2
161/8
5
19 /16
163/16
181/8
263/16
1
18 /8
263/16
181/8
263/16
G
3
/8
5
/16
5
/16
5
/16
5
/16
5
/16
5
/16
5
/16
H
381/2
423/16
441/4
4513/16
453/4
541/8
571/2
571/2
J
1113/16
1113/16
125/8
125/8
133/8
143/16
143/16
143/16
L
123/8
123/8
125/8
125/8
125/8
1711/16
181/2
181/2
WEIGHT
Lb
428
549
635
712
787
1347
1398
1457
OUTPUT
kW
HP
7.5
10
11
15
15
20
18.5
25
22
30
30
40
37
50
45
60
A
838
850
870
882
878
895
895
895
B
430
430
453
453
479
522
522
522
C
622
622
642
642
662
632
632
632
D
217
228
228
241
217
262
262
262
PUMP & MOTOR
E
F
450
414
450
414
470
410
470
410
490
411
461
665
461
665
461
665
G
10
8
8
8
8
8
8
8
H
978
1071
1124
1164
1162
1375
1460
1460
J
300
300
320
320
340
360
360
360
L
315
315
320
320
320
449
470
470
WEIGHT
kg
194
249
288
323
357
611
634
661
Dimensions: mm
PHASE SIZE
ø
MODEL
200DLFU67.5
200DLFU611
200DLFU615
200DLFU618
THREE 150/200
200DLFU622
200DLFU630
200DLFU637
200DLFU645
EBARA Fluid Handling
www.pumpsebara.com
(t) 803 327 5005 • (f) 803 327 5097
2-195
rev. 01/02
DLFU
EBARA Submersible Sewage Pumps
Dimensions
Project:
Model:
Chk’d:
Date:
Model DLFU
250DLFU, 15 to 60HP
t
f
e
ø
(n) QTY - (h) HOLES
Flange (ANSI 125 PSI F.F)
ø
10
e
141/4
f
16
t
13/16
n
12
inch
h
1
ø
250
e
362
f
406
t
30
n
12
mm
h
25
Dimensions: inch
PHASE SIZE
ø
THREE
10
MODEL
250DLFU611
250DLBFU615
250DLCFU615
250DLFU618
250DLFU622
250DLFU630
250DLFU637
250DLFU645
OUTPUT
kW
HP
11
15
15
20
15
20
18.5 25
22
30
30
40
37
50
45
60
A
381/4
381/4
393/16
393/16
393/16
423/8
423/8
423/8
B
205/8
205/8
215/16
215/16
215/16
2311/16
2311/16
2311/16
C
2711/16
2711/16
287/16
287/16
287/16
301/2
301/2
301/2
D
109/16
109/16
103/4
103/4
103/4
1115/16
1115/16
1115/16
PUMP & MOTOR
E
F
1911/16
241/2
1911/16
241/2
1
2
20 /
2415/16
201/2
2415/16
1
2
20 /
2415/16
221/2
2913/16
1
2
22 /
2913/16
221/2
2913/16
G
5
/16
5
/16
5
/16
5
/16
5
/16
5
/16
5
/16
5
/16
H
451/4
4711/16
477/8
497/16
497/16
571/16
603/8
603/8
J
149/16
149/16
153/8
153/8
153/8
175/16
175/16
175/16
L
153/8
161/8
165/16
165/16
165/16
209/16
217/16
217/16
WEIGHT
Lb
736
833
877
959
1030
1570
1631
1713
OUTPUT
kW
HP
11
10
15
20
15
20
18.5 25
22
30
30
40
37
50
45
60
A
972
972
996
996
996
1077
1077
1077
B
524
524
541
541
541
602
602
602
C
703
703
723
723
723
774
774
774
D
269
269
273
273
273
304
304
304
PUMP & MOTOR
E
F
500
622
500
622
520
634
520
634
520
634
571
757
571
757
571
757
G
8
8
8
8
8
8
8
8
H
1149
1211
1216
1256
1256
1449
1534
1534
J
370
370
390
390
390
440
440
440
L
390
410
415
415
415
523
544
544
WEIGHT
kg
334
378
398
435
467
712
740
777
Dimensions: mm
PHASE SIZE
ø
THREE
250
MODEL
250DLFU611
250DLBFU615
250DLCFU615
250DLFU618
250DLFU622
250DLFU630
250DLFU637
250DLFU645
EBARA Fluid Handling
www.pumpsebara.com
(t) 803 327 5005 • (f) 803 327 5097
2-196
rev. 01/02
DLFU
EBARA Submersible Sewage Pumps
Dimensions
Project:
Model:
Chk’d:
Date:
Model DLFU
300DLFU, 25 to 60HP
t
f
e
ø
(n) QTY - (h) HOLES
Flange (ANSI 125 PSI F.F)
ø
12
e
17
f
19
ø
300
e
432
f
483
11/4
n
12
inch
h
1
t
32
n
12
mm
h
25
t
Dimensions: inch
PHASE SIZE
ø
THREE
12
MODEL
300DLFU618
300DLFU622
300DLFU630
300DLFU637
300DLFU645
OUTPUT
kW
HP
18.5
25
22
30
30
40
37
50
45
60
A
44
44
491/8
491/8
491/8
B
231/8
231/8
275/16
275/16
275/16
C
323/16
323/16
355/16
355/16
355/16
D
117/8
117/8
1313/16
1313/16
1313/16
PUMP & MOTOR
E
F
225/8
267/16
225/8
267/16
2513/16
341/8
2513/16
341/8
2513/16
341/8
G
5
/16
5
/16
5
/16
5
/16
5
/16
H
511/8
511/8
6013/16
641/8
641/8
J
169/16
169/16
1911/16
1911/16
1911/16
L
1715/16
1715/16
245/16
253/16
253/16
WEIGHT
Lb
1047
1107
1733
1795
1876
OUTPUT
kW
HP
18.5
25
22
30
30
40
37
50
45
60
A
1118
1118
1248
1248
1248
B
587
587
693
693
693
C
817
817
897
897
897
D
302
302
351
351
351
PUMP & MOTOR
E
F
575
671
575
671
656
867
656
867
656
867
G
8
8
8
8
8
H
1298
1298
1544
1629
1629
J
420
420
500
500
500
L
455
455
618
639
639
WEIGHT
kg
475
502
786
814
851
Dimensions: mm
PHASE
THREE
SIZE
ø
MODEL
300DLFU618
300DLFU622
300 300DLFU630
300DLFU637
300DLFU645
EBARA Fluid Handling
www.pumpsebara.com
(t) 803 327 5005 • (f) 803 327 5097
2-197
rev. 01/02
DLFU
EBARA Submersible Sewage Pumps
Dimensions
Model:
Chk’d:
Model DLFU with Quick Discharge Connector
50DLFU, 2HP
2 / (65)
31 / (800)
80DLFU, 2HP
100DLFU, 2 to 5HP
9
1
16
29/16 (65)
2
Date:
29/16 (65)
Project:
F
279/16 (700)
G
Manhole dimensions in
floor frame installation
Bolt 2– /2 x 1 /16
(12x30)
1
5 /2 (140)
3
23/4 (70)
Floor Frame
Submersible Cable
2 /4 (70)
3
f
e
ø
J
.D.
P.C
Guide pipe length
23/16 (56)
t
SGP (W) 1"
N1
M1
Q
(n) QTY - (h) HOLES
N2
M2
ø
Flange (ANSI 125 PSI F.F)
T
115/16 (50)
1
19/16 (40)
39/16 (90)
Guide pipe support
23/8 (60)
29/16 (65)
13/8 (35)
L . W. L.
U
P
S
L
R
ø1
4 – H Holes
Bolt 2 – /8 (16)
C
B
A
5
315/16
(100)
ø
2
3
4
e
43/4
6
71/2
f
6
71/2
9
t
5
/8
3
/4
15
/16
n
4
4
8
ø
50
80
100
e
121
152
191
f
152
191
229
t
16
19
24
n
4
4
8
inch
h
3
/4
3
/4
3
/4
mm
h
19
19
19
Dimensions: inch
MODEL
PHASE SIZE
ø
2/3 50DLFU61.5
80DLFU61.5
THREE 3/4 100DLFU61.5
100DLFU62.2
100DLFU63.7
LM65
LM80
LM80
LM80
LM80
A
87/16
87/16
87/16
87/16
87/16
B
6
65/8
81/4
81/4
81/4
C
33/4
39/16
39/16
39/16
39/16
H
1
/2
9
/16
9
/16
9
/16
9
/16
J
51/2
61/8
61/8
61/8
61/8
M1
65/16
61/2
711/16
711/16
711/16
QDC
M2 N1
33/4 43/4
39/16 415/16
39/16 415/16
39/16 415/16
39/16 415/16
N2
13/4
115/16
115/16
115/16
115/16
P
511/16
67/8
67/8
67/8
67/8
R
913/16
111/4
1113/16
1113/16
1113/16
PUMP & MOTOR
L
S ø1 F
G
Q
T
71/2 21/2 101/8 181/4 81/4 71/16 295/8
91/16 3 111/2 201/8 95/8 81/4 311/16
91/16 3 101/2 197/16 95/8 77/8 307/8
91/16 3 111/8 201/2 95/8 811/16 313/4
91/16 3 111/8 201/2 95/8 811/16 333/8
WEIGHT Lb
U PUMP QDC
115/16 132 31
29/16 148 37
1 170 37
1 198 37
1 216 37
OUTPUT QDC
kW HP MODEL
1.5 2 LM65
1.5 2 LM80
1.5 2 LM80
2.2 3 LM80
3.7 5 LM80
A
215
215
215
215
215
B
153
168
210
210
210
C
95
90
90
90
90
H
12
15
15
15
15
J
140
155
155
155
155
M1
160
165
195
195
195
QDC
M2 N1
95 120
90 125
90 125
90 125
90 125
N2
45
50
50
50
50
P
145
175
175
175
175
R
250
285
300
300
300
S
190
230
230
230
230
PUMP & MOTOR
G L
Q T
464 210 180 753
511 245 210 789
494 245 200 785
521 245 220 807
521 245 220 847
WEIGHT kg
U PUMP QDC
50 60 14
65 67 17
25 77 17
25 90 17
25 98 17
OUTPUT
kW HP
1.5 2
1.5 2
1.5 2
2.2 3
3.7 5
QDC
MODEL
Dimensions: mm
MODEL
PHASE SIZE
ø
50/80 50DLFU61.5
80DLFU61.5
THREE 80/100 100DLFU61.5
100DLFU62.2
100DLFU63.7
ø1
65
80
80
80
80
F
257
292
267
282
282
*Note: All 80DLFU dimensions are based on 3'' discharge.
All 100DLFU dimensions are based on 4'' discharge.
EBARA Fluid Handling
www.pumpsebara.com
(t) 803 327 5005 • (f) 803 327 5097
2-198
rev. 01/02
DLFU
EBARA Submersible Sewage Pumps
Dimensions
Project:
Model:
Chk’d:
Date:
Model DLFU with Quick Discharge Connector
80DLMFU, 2 to 71/2HP
311/2 (800)
29/16 (65)
29/16 (65)
29/16 (65)
G
F
279/16 (700)
13/8 (35)
23/8 (60)
19/16 (40)
1
3
51/2 (140) Bolt 2– /2 x 1 /16
(12x30)
39/16 (90)
29/16 (65)
Guide pipe support
Floor Frame
Manhole dimensions
floor frame installation
SGP (W) 1"
m
3 /16 (90)
415/16 (125) Q
115/16 (50)
f
e
ø
T
9
ø
155
)
Bolt 2 – 5/8 (16)
39/16 (90)
6 /4 (171) 87/16 (215)
3
315/16 (100)
Dimensions: inch
PUMP MODEL
PHASE SIZE
ø
80DLMFU61.5
80DLMFU62.2
THREE 3/4
80DLMFU63.7
80DLMFU65.5
(n) QTY - (h) HOLES
L
0)
3 (8
t
L . W. L.
Flange (ANSI 125 PSI F.F)
29/16 (65)
/8 (
23/16 (56)
r
91/16 (230)
67/8 (175)
P.C
.D.
61
Guide pipe length
4 - 9/16 (15)Holes
115/16 (50)
23/4 (70)
23/4 (70)
Submersible Cable
ø
3
4
e
6
71/2
f
71/2
9
t
3
/4
15
/16
n
4
8
h
3
/4
3
/4
r
113/16
1113/16
ø
80
100
e
152
191
f
191
229
t
19
24
n
4
8
h
19
19
r
284
300
inch
m
61/2
711/16
mm
m
165
195
OUTPUT
kW
HP
1.5
2
2.2
3
3.7
5
5.5
71/2
Q.D.C.
MODEL
LM80
LM80
LM80
LM80
F
111/2
111/2
121/8
1215/16
PUMP & MOTOR
G
L
Q
205/16
913/16
81/4
205/16
915/16
81/4
21
915/16
811/16
22
127/8
91/4
T
311/16
321/16
335/8
3815/16
WEIGHT Lb
PUMP
Q.D.C.
157
37
187
37
205
37
311
37
OUTPUT
kW
HP
1.5
2
2.2
3
3.7
5
5.5
71/2
Q.D.C.
MODEL
LM80
LM80
LM80
LM80
F
292
292
308
328
PUMP & MOTOR
G
L
Q
516
250
210
516
253
210
534
252
220
559
327
235
T
789
815
854
989
WEIGHT kg
PUMP
Q.D.C.
71
17
85
17
93
17
141
17
Dimensions: mm
PUMP MODEL
PHASE SIZE
ø
80DLMFU61.5
80DLMFU62.2
THREE 80/100
80DLMFU63.7
80DLMFU65.5
EBARA Fluid Handling
www.pumpsebara.com
(t) 803 327 5005 • (f) 803 327 5097
2-199
rev. 11/02
DLFU
EBARA Submersible Sewage Pumps
Dimensions
Project:
Model:
Chk’d:
Date:
Model DLFU with Quick Discharge Connector
80DLCMFU, 10 to 15HP
311/2 (800)
29/16 (65)
29/16 (65)
29/16 (65)
G
29/16 (65)
F
279/16 (700)
23/16 (55)
Guide pipe support
Floor Frame
Bolt 2–5/8 x 13/16
(16x30)
9 /16 (246)
11
57/8 (150)
Manhole dimensions in
floor frame installation
Submersible Cable
4 – 9/16 (15)Holes
T
SGP (W) 11/2"
ø
m
715/16 (185)
43/4 (120)
31/8 (80)
Q
155
)
f
e
ø
L . W. L.
L
97/16 (240)
r
101/16 (255)
)
3 (80
(n) QTY - (h) HOLES
Bolt 2 – 5/8 (16)
63/4 (171)
U
61/2 (165) 23/16 (55)
71/16 (180)
t
P.C
.D.
6 /18
(
Guide pipe length
23/4 (70)
65/16 (160)
315/16 (100)
33/8 (85)
Flange (ANSI 125 PSI F.F)
12 (305)
ø
3
4
e
6
71/2
f
71/2
9
t
3
/4
15
/16
n
4
8
h
3
/4
3
/4
r
133/4
143/8
ø
80
100
e
152
191
f
191
229
t
19
24
n
4
8
h
19
19
r
350
365
inch
m
711/16
87/8
mm
m
195
226
Dimensions: inch
PHASE
SIZE
ø
MODEL
THREE
3/4
80DLCMFU67.5
80DLCMFU611
OUTPUT
kW
HP
7.5
10
11
15
Q.D.C.
MODEL
LL80
LL80
F
1415/16
1511/16
G
273/16
283/8
PUMP & MOTOR
Q
L
101/4
111/8
11
111/4
T
375/16
411/16
U
111/16
13/4
OUTPUT
kW
HP
7.5
10
11
15
Q.D.C.
MODEL
LL80
LL80
F
379
399
G
690
720
PUMP & MOTOR
Q
L
260
283
280
285
T
948
1043
U
43
45
WEIGHT Lb
PUMP
Q.D.C.
375
97
500
97
Dimensions: mm
PHASE
SIZE
ø
MODEL
80DLCMFU67.5
THREE 80/100
80DLCMFU611
EBARA Fluid Handling
www.pumpsebara.com
(t) 803 327 5005 • (f) 803 327 5097
WEIGHT Lb
PUMP
170
227
Q.D.C.
44
44
2-200
rev. 01/02
DLFU
EBARA Submersible Sewage Pumps
Dimensions
Project:
Model:
Chk’d:
Model DLFU with Quick Discharge Connector
80DLFU, 3 to 30HP
2 / (65)
31 / (800)
1
16
29/16 (65)
2
29/16 (65)
9
Date:
G
29/16 (65)
F
279/16 (700)
23/16 (55)
Guide pipe support
Floor Frame
Bolt 2–5/8 x 13/16
(16x30)
t
SGP (W) 11/2"
ø
81/4 (210)
41/8 (105)
75/16 (185)
(n) QTY - (h) HOLES
Q
T
4 – 3/4 (19) Holes
P.C
.D.
6 /78
(17
5)
f
e
ø
33/8 (85)
Guide pipe length
23/4 (70)
65/16 (160)
Manhole dimensions in
floor frame installation
Submersible Cable
315/16 (100)
9 /16 (246)
57/8 (150)
11
31/8 (80)
L.W.L.
)
U
L
143/8 (365)
107/16 (265)
97/16 (240)
ø 4 (100
61/2 (165) 23/16 (55)
71/16 (180)
Flange (ANSI 125 PSI F.F)
Bolt 4 – 5/8 (16)
81/4 (210)
117/16 (290)
ø
3
4
e
6
71/2
f
71/2
9
t
3
/4
15
/16
n
4
8
inch
h
3
/4
3
/4
ø
80
100
e
152
191
f
191
229
t
19
24
n
4
8
mm
h
19
19
Dimensions: inch
PHASE SIZE
ø
MODEL
80DLFU62.2
80DLFU63.7
80DLFU65.5
80DLFU67.5
THREE 3/4
80DLFU611
80DLFU615
80DLFU618
80DLFU622
OUTPUT
kW
HP
2.2
3
3.7
5
5.5
71/2
7.5
10
11
15
15
20
18.5
25
22
30
Q.D.C.
MODEL
LL100
LL100
LL100
LL100
LL100
LL100
LL100
LL100
F
133/16
133/16
133/16
141/2
153/16
153/16
1513/16
1513/16
G
253/8
253/8
253/8
269/16
2711/16
2711/16
283/4
283/4
PUMP & MOTOR
L
Q
125/8
91/4
125/8
91/4
159/16
91/4
1113/16
913/16
115/8
105/8
123/8
105/8
123/8
117/16
123/8
117/16
T
343/4
365/16
415/8
3711/16
415/16
441/8
4511/16
4511/16
U
41/2
41/2
41/2
15/8
15/8
15/8
15/8
15/8
WEIGHT Lb
PUMP
Q.D.C.
209
101
209
101
317
101
344
101
470
101
564
101
639
101
694
101
OUTPUT
kW
HP
2.2
3
3.7
5
5.5
71/2
7.5
10
11
15
15
20
18.5
25
22
30
Q.D.C.
MODEL
LL100
LL100
LL100
LL100
LL100
LL100
LL100
LL100
F
335
335
335
369
385
385
402
402
G
644
644
644
675
703
703
730
730
PUMP & MOTOR
Q
L
235
320
235
320
235
395
250
300
270
295
270
315
290
315
290
315
T
883
923
1058
958
1050
1120
1160
1160
U
115
115
115
42
42
42
42
42
WEIGHT kg
PUMP
Q.D.C.
95
46
95
46
144
46
156
46
213
46
256
46
290
46
315
46
Dimensions: mm
PHASE SIZE
ø
MODEL
80DLFU62.2
80DLFU63.7
80DLFU65.5
80DLFU67.5
THREE 80/100
80DLFU611
80DLFU615
80DLFU618
80DLFU622
EBARA Fluid Handling
www.pumpsebara.com
(t) 803 327 5005 • (f) 803 327 5097
2-201
rev. 12/03
DLFU
EBARA Submersible Sewage Pumps
Dimensions
Project:
Model:
Chk’d:
Model DLFU with Quick Discharge Connector
100DLMFU, 3 to 30HP 2 / (65)
31 / (800)
2/
1
16
9
2
(65)
16
29/16 (65)
9
Date:
G
29/16 (65)
F
279/16 (700)
23/16 (55)
Guide pipe support
Floor Frame
Bolt 2–5/8 x 13/16
(16x30)
315/16 (100)
4 – 3/4 (19) Holes
175
)
t
SGP (W) 11/2"
ø
81/4 (210)
41/8 (105)
75/16 (185)
(n) QTY - (h) HOLES
Q
31/8 (80)
0)
Flange (ANSI 125 PSI F.F)
L.W.L.
L
3
ø 4 (10
f
e
ø
33/8 (85)
14 /8 (365)
107/16 (265)
97/16 (240)
P.C
.D.
6 /78
(
floor frame installation
Submersible Cable
Guide pipe length
23/4 (70)
65/16 (160)
Manhole dimensions in
T
9 /16 (246)
57/8 (150)
11
Bolt 4 – 5/8 (16)
81/4 (210)
117/16 (290)
Dimensions: inch
PHASE SIZE
ø
THREE
3
4
6
MODEL
100DLMFU62.2
100DLMFU63.7
100DLMFU65.5
100DLMFU67.5
100DLMFU611
100DLMFU615
100DLMFU618
100DLMFU622
OUTPUT
HP
kW
3
2.2
5
3.7
71/2
5.5
10
7.5
15
11
20
15
25
18.5
30
22
e
6
71/2
91/2
f
71/2
9
11
t
3
/4
15
/16
1
n
4
8
8
inch
h
3
/4
3
/4
3
/4
ø
80
100
150
e
152
191
240
f
191
229
280
t
19
24
24
n
4
8
8
mm
h
19
19
19
U
61/2 (165) 23/16 (55)
71/16 (180)
ø
3
4
6
Q.D.C.
MODEL
LL100
LL100
LL100
LL100
LL100
LL100
LL100
LL100
F
133/16
133/16
133/16
141/2
153/16
153/16
1513/16
1513/16
G
253/8
253/8
253/8
269/16
2711/16
2711/16
283/4
283/4
PUMP & MOTOR
L
Q
125/8
91/4
125/8
91/4
9
15 /16
91/4
1113/16
913/16
115/8
105/8
123/8
105/8
3
12 /8
117/16
123/8
117/16
T
343/4
365/16
415/8
3711/16
415/16
441/8
4511/16
4511/16
U
41/2
41/2
41/2
15/8
15/8
15/8
15/8
15/8
WEIGHT Lb
PUMP
Q.D.C.
209
101
209
101
317
101
344
101
470
101
564
101
639
101
694
101
Q.D.C.
MODEL
LL100
LL100
LL100
LL100
LL100
LL100
LL100
LL100
F
335
335
335
369
385
385
402
402
G
644
644
644
675
703
703
730
730
PUMP & MOTOR
L
Q
320
235
320
235
395
235
300
250
295
270
315
270
315
290
315
290
T
883
923
1058
958
1050
1120
1160
1160
U
115
115
115
42
42
42
42
42
WEIGHT kg
PUMP
Q.D.C.
95
46
95
46
144
46
156
46
213
46
256
46
290
46
315
46
Dimensions: mm
PHASE SIZE
ø
MODEL
100DLMFU62.2
100DLMFU63.7
100DLMFU65.5
80
100DLMFU67.5
THREE 100
150 100DLMFU611
100DLMFU615
100DLMFU618
100DLMFU622
OUTPUT
kW
HP
2.2
3
3.7
5
5.5
71/2
7.5
10
11
15
15
20
18.5
25
22
30
EBARA Fluid Handling
www.pumpsebara.com
2-201.1
(t) 803 327 5005 • (f) 803 327 5097
rev. 03/13
DLFU
EBARA Submersible Sewage Pumps
Dimensions
Project:
Model:
Chk’d:
Model DLFU with Quick Discharge Connector
100DLFU, 71/2 to 30HP
Date:
)
*
*XLGH3LSH6XSSRUW
0DQKROHGLPHQVLRQVLQ
IORRUIUDPHLQVWDOODWLRQ
%ROW [ >[@
)ORRU)UDPH
6XEPHUVLEOH&DEOH
6*3:
'
&
3
*XLGHSLSHOHQJWK
P
f
e
ø
7
4
t
>@+ROHV
(n) QTY - (h) HOLES
8
/
N
U
0
;
/:/
%ROW >@
inch
Dimensions: inch
PHASE SIZE
ø
MODEL
100DLFU65.5
100DLFU67.5
100DLFU611
THREE 4/6
100DLFU615
100DLFU618
100DLFU622
Flange (ANSI 125 PSI F.F)
OUTPUT
kW
HP
5.5
71/2
7.5
10
11
15
15
20
18.5
25
22
30
ø
4
6
e
71/2
91/2
f
9
11
t
15
/16
1
n
8
8
h
3
/4
7
/8
ø
100
150
e
191
241
f
229
279
t
24
25
n
8
8
h
19
22
r
m
1711/16 1213/16
185/16 139/16
r
450
465
m
326
345
k
95/8
113/8
mm
m
245
290
Q.D.C.
MODEL
LL125
LL125
LL125
LL125
LL125
LL125
F
1511/16
1511/16
1511/16
167/16
171/4
171/4
G
2613/16
2613/16
2613/16
28
293/16
293/16
PUMP & MOTOR
Q
L
11
143/8
11
143/8
11
143/8
1113/16
145/8
125/8
145/8
125/8
145/8
T
403/16
403/16
4313/16
463/16
473/4
473/4
U
211/16
211/16
211/16
27/8
27/8
27/8
WEIGHT Lb
PUMP
Q.D.C.
353
143
395
143
476
143
602
143
677
143
736
143
Q.D.C.
MODEL
LL125
LL125
LL125
LL125
LL125
LL125
F
398
398
398
418
438
438
G
681
681
681
711
741
741
PUMP & MOTOR
L
Q
366
280
366
280
366
280
372
300
372
320
372
320
T
1021
1021
1114
1173
1213
1213
U
69
69
69
73
73
73
WEIGHT kg
PUMP
Q.D.C.
160
65
179
65
216
65
273
65
307
65
334
65
Dimensions: mm
PHASE SIZE
ø
MODEL
100DLFU65.5
100DLFU67.5
100DLFU611
THREE 100/150
100DLFU615
100DLFU618
100DLFU622
OUTPUT
kW
HP
5.5
71/2
7.5
10
11
15
15
20
18.5
25
22
30
EBARA Fluid Handling
www.pumpsebara.com
(t) 803 327 5005 • (f) 803 327 5097
2-202
rev. 04/15
DLFU
EBARA Submersible Sewage Pumps
Dimensions
Project:
Model:
Chk’d:
Date:
Model DLFU with Quick Discharge Connector
100DLFU, 40 to 60HP
*
%ROW [ >[@
)
*XLGH3LSH6XSSRUW
0DQKROHGLPHQVLRQVLQ
IORRUIUDPHLQVWDOODWLRQ
)ORRU)UDPH
6XEPHUVLEOH&DEOH
/:/
*XLGHSLSHOHQJWK
6*3:
P
4
f
e
ø
7
'
/
&
3
+ROHV
%ROW >@
Flange (ANSI 125 PSI F.F)
8
(n) QTY - (h) HOLES
N
0
;
U
t
inch
ø
4
6
e
71/2
91/2
f
9
11
t
15
/16
1
n
8
8
h
3
/4
7
/8
ø
100
150
e
191
241
f
229
279
t
24
25
n
8
8
h
19
22
r
m
1711/16 1213/16
185/16 139/16
r
450
465
m
325
345
k
95/8
113/8
mm
m
245
290
Dimensions: inch
PHASE SIZE
ø
THREE
4
MODEL
100DLFU630
100DLFU637
100DLFU645
OUTPUT
kW
HP
30
40
37
50
45
60
Q.D.C.
MODEL
LL125HH
LL125HH
LL125HH
F
199/16
199/16
199/16
G
357/8
357/8
357/8
PUMP & MOTOR
Q
L
143/16
4711/16
143/16
513/16
143/16
513/16
T
541/16
579/16
579/16
U
63/16
63/16
63/16
WEIGHT Lb
PUMP
Q.D.C.
1001
183
1171
183
1219
183
OUTPUT
kW
HP
30
40
37
50
45
60
Q.D.C.
MODEL
LL125HH
LL125HH
LL125HH
F
497
497
497
G
911
911
911
PUMP & MOTOR
L
Q
1211
360
1301
360
1301
360
T
1373
1462
1462
U
157
157
157
WEIGHT kg
PUMP
Q.D.C.
454
83
531
83
553
83
Dimensions: mm
PHASE SIZE
ø
MODEL
100DLFU630
THREE 100 100DLFU637
100DLFU645
EBARA Fluid Handling
www.pumpsebara.com
(t) 803 327 5005 • (f) 803 327 5097
2-203
rev. 04/15
DLFU
EBARA Submersible Sewage Pumps
Dimensions
Project:
Model:
Chk’d:
Date:
Model DLFU with Quick Discharge Connector
150DLFU, 10 to 30HP
435/16 (1100)
29/16 (65)
29/16 (65)
29/16 (65)
G
29/16 (65)
F
311/2 (800)
115/16 (50)
Guide pipe support
Manhole dimensions in
floor frame installation
Submersible Cable
39/16 (90)
SGP (W) 2"
f
e
ø
14 (355)
61/8
(155)
Q
t
81/16
(205)
(n) QTY - (h) HOLES
/
13 16
9
.D.
P.C
ø
4 – 3/4 (19) Holes
T
23/4 (70)
65/16 (160)
315/16 (100)
Guide pipe length
39/16 (90)
5 7/8(150)
Floor Frame
19/16 (40)
Bolt 2–5/8 x 13/16
(16x30)
109/16 (268)
Flange (ANSI 125 PSI F.F)
1113/16 (300)
0)
L
(15
ø
6
8
e
91/2
113/4
f
11
131/2
t
1
11/8
n
8
8
inch
h
7
/8
7
/8
ø
150
200
e
241
298
f
279
343
t
25
29
n
8
8
mm
h
22
22
U
ø6
191/2 (495)
15
15 /16 (405)
125/8 (320)
L . W. L.
Bolt 4–5/8
(16)
811/16 (220) 611/16 (170)
123/8 (315)
143/16 (360)
Dimensions: inch
PHASE SIZE
ø
MODEL
150DLFU67.5
150DLFU611
THREE 6/8 150DLFU615
150DLFU618
150DLFU622
HP
10
15
20
25
30
Q.D.C.
MODEL
LL150
LL150
LL150
LL150
LL150
F
1615/16
1615/16
1713/16
1713/16
187/8
G
287/16
287/16
295/8
295/8
3015/16
PUMP & MOTOR
L
Q
159/16
1113/16
159/16
1113/16
1
16 /16
125/8
161/16
125/8
15
15 /16
133/8
T
4111/16
453/8
475/8
493/16
491/16
U
33/16
33/16
33/8
33/8
35/16
WEIGHT Lb
PUMP
Q.D.C.
428
176
549
176
635
176
712
176
787
176
OUTPUT
kW
HP
7.5
10
11
15
15
20
18.5
25
22
30
Q.D.C.
MODEL
LL150
LL150
LL150
LL150
LL150
F
430
430
453
453
479
G
722
722
753
753
786
PUMP & MOTOR
L
Q
396
300
396
300
408
320
408
320
405
340
T
1059
1152
1209
1249
1246
U
81
81
85
85
84
WEIGHT kg
PUMP
Q.D.C.
194
80
249
80
288
80
323
80
357
80
OUTPUT
kW
7.5
11
15
18.5
22
Dimensions: mm
PHASE SIZE
ø
MODEL
150DLFU67.5
150DLFU611
THREE 150/200 150DLFU615
150DLFU618
150DLFU622
EBARA Fluid Handling
www.pumpsebara.com
(t) 803 327 5005 • (f) 803 327 5097
2-204
rev. 01/02
DLFU
EBARA Submersible Sewage Pumps
Dimensions
Project:
Model:
Chk’d:
Date:
Model DLFU with Quick Discharge Connector
200DLFU, 10 to 30HP
435/16 (1100)
29/16 (65)
29/16 (65)
29/16 (65)
G
29/16 (65)
F
311/2 (800)
115/16 (50)
Guide pipe support
Manhole dimensions in
floor frame installation
315/16 (100)
Guide pipe length
Submersible Cable
39/16 (90)
SGP (W) 2"
f
e
ø
14 (355)
61/8
(155)
Q
t
81/16
(205)
13 16
9
.D.
P.C
(n) QTY - (h) HOLES
ø
4 – 3/4 (19) Holes
T
65/16 (160)
23/4 (70)
39/16 (90)
57/8(150)
Floor Frame
19/16 (40)
Bolt 2–5/8 x 13/16
(16x30)
109/16 (268)
/
Flange (ANSI 125 PSI F.F)
0)
Bolt 4– /
(16)
5
1113/16 (300)
L
(15
U
ø6
191/2 (495)
1515/16 (405)
125/8 (320)
L . W. L.
8 /16 (220) 6 / (170)
123/8 (315)
143/16 (360)
11
8
11
16
ø
6
8
e
91/2
113/4
f
11
131/2
t
1
11/8
n
8
8
inch
h
7
/8
7
/8
ø
150
200
e
241
298
f
279
343
t
25
29
n
8
8
h
22
22
mm
Dimensions: inch
PHASE SIZE
ø
MODEL
200DLFU67.5
200DLFU611
THREE 6/8 200DLFU615
200DLFU618
200DLFU622
OUTPUT
kW
HP
7.5
10
11
15
15
20
18.5
25
22
30
Q.D.C.
MODEL
LL150
LL150
LL150
LL150
LL150
F
1615/16
1615/16
1713/16
1713/16
187/8
G
287/16
287/16
295/8
295/8
3015/16
PUMP & MOTOR
L
Q
159/16
1113/16
159/16
1113/16
1
16 /16
125/8
161/16
125/8
15
15 /16
133/8
T
4111/16
453/8
475/8
493/16
491/16
U
33/16
33/16
33/8
33/8
35/16
WEIGHT Lb
PUMP
Q.D.C.
428
176
549
176
635
176
712
176
787
176
Q.D.C.
MODEL
LL150
LL150
LL150
LL150
LL150
F
430
430
453
453
479
G
722
722
753
753
786
PUMP & MOTOR
L
Q
396
300
396
300
408
320
408
320
405
340
T
1059
1152
1209
1249
1246
U
81
81
85
85
84
WEIGHT kg
PUMP
Q.D.C.
194
80
249
80
288
80
323
80
357
80
Dimensions: mm
PHASE SIZE
ø
MODEL
200DLFU67.5
200DLFU611
THREE 150/200 200DLFU615
200DLFU618
200DLFU622
OUTPUT
HP
kW
10
7.5
15
11
20
15
25
18.5
30
22
EBARA Fluid Handling
www.pumpsebara.com
(t) 803 327 5005 • (f) 803 327 5097
2-205
rev. 01/02
DLFU
EBARA Submersible Sewage Pumps
Dimensions
Project:
Model:
Chk’d:
Date:
Model DLFU with Quick Discharge Connector
150DLFU, 40 to 60HP
200DLFU, 40 to 60HP
G
F
E1
E2
Floor Frame
D1
D2
Floor plate
45/16 (110)
Guide pipe support
3
/16 (5)
57/8 (150)
19/16 (40)
Bolt 2–5/8 x 13/16
(16x30)
SGP (W) 2"
N
39/16 (90)
65/16 (160)
P
T
Q
f
e
ø
6 /8 (155)
t
1
ø
(n) QTY - (h) HOLES
L . W. L.
A1
B1
315/16
(100)
A2
B2
ø
6
8
e
91/2
113/4
f
11
131/2
t
1
11/8
n
8
8
inch
h
7
/8
7
/8
ø
150
200
e
241
298
f
279
343
t
25
29
n
8
8
mm
h
22
22
L
123/8 (315)
U
S
R
23/8 (60)
Flange (ANSI 125 PSI F.F)
Bolt 4 – 15/16 (24)
Dimensions: inch
PHASE SIZE
ø
6
THREE
8
MODEL
150DLFU630
150DLFU637
150DLFU645
200DLFU630
200DLFU637
200DLFU645
OUTPUT
kW HP
30 40
37 50
45 60
30 40
37 50
45 60
QDC
MODEL
LL150YU
LL150YU
LL150YU
LL200YU
LL200YU
LL200YU
A1
161/8
161/8
161/8
175/16
175/16
175/16
A2
143/16
143/16
143/16
169/16
169/16
169/16
B1
201/2
201/2
201/2
215/8
215/8
215/8
B2
161/8
161/8
161/8
181/2
181/2
181/2
F
189/16
189/16
189/16
209/16
209/16
209/16
PUMP & MOTOR
L
G
N
P
315/16 1513/16 91/4 1213/16
315/16 165/8 91/4 1213/16
315/16 165/8 91/4 1213/16
321/2 171/2 107/16 14
321/2 185/16 107/16 14
321/2 185/16 107/16 14
Q
197/8
197/8
197/8
201/4
201/4
201/4
R
1911/16
1911/16
1911/16
235/8
235/8
235/8
S
153/16
153/16
153/16
163/4
163/4
163/4
T
471/16
503/8
503/8
471/16
503/8
503/8
U
51/4
51/4
51/4
67/8
67/8
67/8
ACCESS HOLE
D1 D2 E1 E2
393/4 447/8 279/16 3211/16
393/4 447/8 279/16 3211/16
393/4 447/8 279/16 3211/16
435/16 487/16 311/2 365/8
435/16 487/16 311/2 365/8
435/16 487/16 311/2 365/8
QDC
MODEL
LL150YU
LL150YU
LL150YU
LL200YU
LL200YU
LL200YU
A1
410
410
410
440
440
440
A2
360
360
360
420
420
420
B1
520
520
520
550
550
550
B2
410
410
410
470
470
470
F
471
471
471
522
522
522
PUMP & MOTOR
G
L
N P
795 402 235 325
795 423 235 325
795 423 235 325
825 444 265 355
825 465 265 355
825 465 265 355
Q
505
505
505
515
515
515
R
500
500
500
600
600
600
S
385
385
385
425
425
425
T
1195
1280
1280
1195
1280
1280
U
133
133
133
175
175
175
ACCESS HOLE
D1 D2 E1 E2
1010 1140 700 830
1010 1140 700 830
1010 1140 700 830
1100 1230 800 930
1100 1230 800 930
1100 1230 800 930
WEIGHT Lb
PUMP QDC
1294
1345
1404
1347
1398
1457
179
179
179
227
227
227
Dimensions: mm
PHASE SIZE
ø
MODEL
150DLFU630
150 150DLFU637
150DLFU645
THREE
200DLFU630
200 200DLFU637
200DLFU645
OUTPUT
kW HP
30 40
37 50
45 60
30 40
37 50
45 60
EBARA Fluid Handling
www.pumpsebara.com
(t) 803 327 5005 • (f) 803 327 5097
WEIGHT kg
PUMP QDC
587
610
637
611
634
661
81
81
81
103
103
103
2-206
rev. 01/02
DLFU
EBARA Submersible Sewage Pumps
Dimensions
Project:
Model:
Chk’d:
Date:
Model DLFU with Quick Discharge Connector
250DLFU, 15 to 30HP
471/4 (1200)
29/16 (65)
29/16 (65)
29/16 (65)
Manhole dimensions in
floor frame installation
G
F
357/16 (900)
G
Guide pipe length
315/16 (100)
13
/16 (30)
29/16 (65)
Floor Frame
Bolt 2–5/8 x 13/16 77/8 (200)
(16x30)
97/16 (240)
Submersible Cable
4 /4 (120)
3
SGP (W) 3"
17 / (435)
1
8
7 /16
(195)
11
f
e
ø
Q
T
t
ø
279/16 (700)
175/16 (440)
133/4 (350)
L
Flange (ANSI 125 PSI F.F)
U
153/4 (400)
(n) QTY - (h) HOLES
L . W. L.
Bolt 4 – 13/16 (30)
1911/16 (500)
235/8 (600)
259/16 (650)
317/8 (810)
ø
10
e
141/4
f
16
t
13/16
n
12
inch
h
1
ø
250
e
362
f
406
t
30
n
12
mm
h
25
Dimensions: inch
PHASE SIZE
ø
MODEL
THREE 10
250DLFU611
250DLBFU615
250DLCFU615
250DLFU618
250DLFU622
OUTPUT
kW
HP
11
15
15
20
15
20
18.5
25
22
30
Q.D.C.
MODEL
LL250U
LL250U
LL250U
LL250U
LL250U
F
205/8
205/8
215/16
215/16
215/16
G
357/16
357/16
363/8
363/8
363/8
PUMP & MOTOR
L
Q
173/4
149/16
187/16
149/16
181/8
153/8
181/8
153/8
181/8
153/8
T
471/2
4915/16
4911/16
511/4
511/4
U
25/16
25/16
113/16
113/16
113/16
WEIGHT Lb
PUMP
Q.D.C.
736
331
833
331
877
331
959
331
1030
331
Q.D.C.
MODEL
LL250U
LL250U
LL250U
LL250U
LL250U
F
524
524
541
541
541
G
900
900
924
924
924
PUMP & MOTOR
L
Q
451
370
468
370
461
390
461
390
461
390
T
1207
1269
1262
1302
1302
U
58
58
46
46
46
WEIGHT kg
PUMP
Q.D.C.
334
150
378
150
398
150
435
150
467
150
Dimensions: mm
PHASE SIZE
ø
MODEL
250DLFU611
250DLBFU615
THREE 250 250DLCFU615
250DLFU618
250DLFU622
OUTPUT
kW
11
15
15
18.5
22
HP
15
20
20
25
30
EBARA Fluid Handling
www.pumpsebara.com
(t) 803 327 5005 • (f) 803 327 5097
2-207
rev. 01/02
DLFU
EBARA Submersible Sewage Pumps
Dimensions
Project:
Model:
Chk’d:
Date:
Floor Frame
Model DLFU with Quick Discharge Connector
250DLFU, 40 TO 60HP
300DLFU, 40 TO 60HP
D2
/16
3
N
(5)
Floor plate
Guide pipe support
45/16 (110)
19/16 (40)
E1
D1
Bolt 2–5/8 x 13/16
(16x30)
57/8 (150)
E2
F
G
43/4 (120)
f
e
ø
SGP (W) 3"
97/16 (240)
t
Q
T
P
6 /8 (155)
1
(n) QTY - (h) HOLES
ø
Flange (ANSI 125 PSI F.F)
123/8 (315)
U
L
S
R
23/8 (60)
L . W. L.
315/16
(100)
e
141/4
17
f
16
19
t
13/16
11/4
n
12
12
inch
h
1
1
ø
250
300
e
362
432
f
406
483
t
30
32
n
12
12
mm
h
25
25
31/8 (80)
A1
B1
ø
10
12
Bolt 4 – 13/16 (30)
Dimensions: inch
PHASE SIZE
ø
MODEL
250DLFU630
10 250DLFU637
250DLFU645
THREE
300DLFU630
12 300DLFU637
300DLFU645
OUTPUT
kW HP
30 40
37 50
45 60
30 40
37 50
45 60
QDC
MODEL
LL250YU
LL250YU
LL250YU
LL300YU
LL300YU
LL300YU
A1
259/16
259/16
259/16
263/4
263/4
263/4
A2
1911/16
1911/16
1911/16
2213/16
2213/16
2213/16
B1
311/8
311/8
311/8
325/16
325/16
325/16
B2
221/16
221/16
221/16
253/16
253/16
253/16
F
2311/16
2311/16
2311/16
275/16
275/16
275/16
PUMP & MOTOR
G
L
N
P
393/4 179/16 123/8 171/8
393/4 183/8 123/8 171/8
393/4 183/8 123/8 171/8
437/8 207/8 139/16 185/16
437/8 213/4 139/16 185/16
437/8 213/4 139/16 185/16
Q
25
25
25
273/8
273/8
273/8
R
279/16
279/16
279/16
311/2
311/2
311/2
S
175/16
175/16
175/16
215/8
215/8
215/8
T
483/8
513/4
513/4
509/16
537/8
537/8
U
83/4
83/4
83/4
915/16
915/16
915/16
ACCESS HOLE
D1 D2 E1 E2
471/4 531/8 357/16 415/16
471/4 531/8 357/16 415/16
471/4 531/8 357/16 415/16
513/16 571/16 393/8 451/4
513/16 571/16 393/8 451/4
513/16 571/16 393/8 451/4
A1
650
650
650
680
680
680
A2
500
500
500
580
580
580
B1
790
790
790
820
820
820
B2
560
560
560
640
640
640
F
602
602
602
693
693
693
PUMP & MOTOR
G
L
P
N
1010 446 315 435
1010 467 315 435
1010 467 315 435
1115 531 345 465
1115 552 345 465
1115 552 345 465
Q
635
635
635
695
695
695
R
700
700
700
800
800
800
S
440
440
440
550
550
550
T
1229
1314
1314
1284
1369
1369
U
223
223
223
253
253
253
ACCESS HOLE
D1
D2
E1
E2
1200 1350 900 1050
1200 1350 900 1050
1200 1350 900 1050
1300 1450 1000 1150
1300 1450 1000 1150
1300 1450 1000 1150
WEIGHT Lb
PUMP QDC
1570
1631
1713
1733
1795
1876
344
344
344
450
450
450
Dimensions: mm
PHASE SIZE
ø
MODEL
250DLFU630
250 250DLFU637
250DLFU645
THREE
300DLFU630
300 300DLFU637
300DLFU645
OUTPUT
kW HP
30 40
37 50
45 60
30 40
37 50
45 60
QDC
MODEL
LL250YU
LL250YU
LL250YU
LL300YU
LL300YU
LL300YU
EBARA Fluid Handling
www.pumpsebara.com
(t) 803 327 5005 • (f) 803 327 5097
WEIGHT kg
PUMP QDC
712
740
777
786
814
851
156
156
156
204
204
204
2-208
rev. 07/03
DLFU
EBARA Submersible Sewage Pumps
Dimensions
Project:
Model:
Chk’d:
Date:
Model DLFU with Quick Discharge Connector
300DLFU, 25 to 30HP
215/16 (75)
471/4 (1200)
215/16 (75)
215/16 (75)
Manhole dimensions in
floor frame installation
215/16 (75)
F
357/16 (900)
G
315/16 (100)
13/16 (30)
Floor Frame
Bolt 2–5/8 x 13/16 77/8 (200)
(16x30)
Guide pipe length
43/4 (120)
SGP (W) 3"
185/16 (465)
711/16
(195)
Q
ø
(n) QTY - (h) HOLES
L
215/8 (550)
1615/16 (430)
Flange (ANSI 125 PSI F.F)
U
311/2 (800)
2213/16 (580)
253/16 (640)
t
L . W. L.
Bolt 4 – 13/16 (30)
153/4 (400)
f
e
ø
T
97/16 (240)
Submersible Cable
263/4 (680)
331/16 (840)
ø
12
e
17
f
19
ø
300
e
432
f
483
11/4
n
12
inch
h
1
t
32
n
12
mm
h
25
t
Dimensions: inch
PHASE
SIZE
ø
THREE
12
MODEL
300DLFU618
300DLFU622
OUTPUT
kW
HP
18.5
25
22
30
Q.D.C.
MODEL
LL300U
LL300U
F
231/8
231/8
G
3811/16
3811/16
PUMP & MOTOR
Q
L
169/16
225/16
169/16
225/16
T
553/8
553/8
U
45/16
45/16
WEIGHT Lb
PUMP
Q.D.C.
1047
331
1107
331
OUTPUT
kW
HP
18.5
25
22
30
Q.D.C.
MODEL
LL300U
LL300U
F
587
587
G
983
983
PUMP & MOTOR
L
Q
566
420
566
420
T
1407
1407
U
109
109
WEIGHT kg
PUMP
Q.D.C.
475
150
502
150
Dimensions: mm
PHASE
SIZE
ø
THREE
300
MODEL
300DLFU618
300DLFU622
EBARA Fluid Handling
www.pumpsebara.com
(t) 803 327 5005 • (f) 803 327 5097
2-209
rev. 01/02
DLFU
EBARA Submersible Sewage Pumps
Sectional View
Project:
Model:
Chk’d:
Date:
2 to 5HP
924
811
1
200
838
811
2
115
4
817
120
7
115
3
120
6
849
2
814
876
830
849
801
909
802
120
5
193
2
115
2
120
4
120
3
816
193
1
213
115
1
120
2
174
005
117
021
080
120
1
PART
NO.
001
005
†012
†021
039
080
†111
†115-1
†115-2
†115-3
†115-4
†117
120-1
120-2
120-3
120-4
120-5
120-6
120-7
125
PART NAME
CASING
INTERMEDIATE CASING
SUCTION COVER
IMPELLER
KEY
BUSHING
MECHANICAL SEAL
O-RING
O-RING
O-RING
O-RING
GASKET
BOLT
BOLT
BOLT
BOLT
BOLT
BOLT
BOLT
BOLT
012
125 039
ASTM, AISI
CODE
NO. FOR
1 UNIT
CAST IRON
CAST IRON
CAST IRON
CAST IRON
420 STAINLESS
STEEL
—
RUBBER (NBR)
RUBBER (NBR)
RUBBER (NBR)
RUBBER (NBR)
A48 Class 30
A48 Class 30
A48 Class 30
A48 Class 30
AISI420
A283 Grade D
304 STAINLESS
304 STAINLESS
304 STAINLESS
304 STAINLESS
304 STAINLESS
304 STAINLESS
304 STAINLESS
304 STAINLESS
AISI304
AISI304
AISI304
AISI304
AISI304
AISI304
AISI304
AISI304
1
1
1
1
1
1
1 SET
1
1
1
2
1
4
8
4
4
3
4
2
1
MATERIAL
PART
NO.
174
193-1
193-2
200
213
801
802
811-1
811-2
814
816
817
830
838
†849-1
†849-2
876
909
924
001 111
PART NAME
DISCHARGE ELBOW
PLUG
PLUG
LIFTING HANGER
AIR VENT VALVE
ROTOR
STATOR
POWER CABLE
CONTROL CABLE
MOTOR COVER
BRACKET
BRACKET
SHAFT
WASHER
BALL BEARING
BALL BEARING
MOTOR PROTECTOR
LEAKAGE DETECTOR
PACKING
MATERIAL
CAST IRON
304 STAINLESS
304 STAINLESS
STEEL
BRASS
—
—
—
—
CAST IRON
CAST IRON
CAST IRON
403 STAINLESS
304 STAINLESS
—
—
—
—
RUBBER (NBR)
ASTM, AISI
CODE
A48 Class 30
AISI304
AISI304
A283 Grade D
B36 No. 272
A48 Class 30
A48 Class 30
A48 Class 30
AISI403
AISI304
NO. FOR
1 UNIT
1
1
1
1
1
1
1
1
1
1
1
1
1
2
1
1
3
1
2
Motors are purchased as a complete unit
†: Recommended spare parts
EBARA Fluid Handling
www.pumpsebara.com
(t) 803 327 5005 • (f) 803 327 5097
2-210
rev. 01/02
DLFU
EBARA Submersible Sewage Pumps
Sectional View
Project:
Model:
Chk’d:
Date:
71/2 to 10HP
838 924 811
817 115
4
1
1
1
200
120
7
811
2
924
2
838
2
115
3
115
5
849
2
876
120
6
814
801
830
802
849
1
120
5
909
120
4
115
2
193
2
816
193
1
120
3
213
115
1
120
2
005
001
111
PART
NO.
001
005
†012
†021
039
†111
†114
†115-1
†115-2
†115-3
†115-4
†115-5
†117
120-1
120-2
120-3
120-4
120-5
120-6
120-7
125
PART NAME
CASING
INTERMEDIATE CASING
SUCTION COVER
IMPELLER
KEY
MECHANICAL SEAL
OIL SEAL
O-RING
O-RING
O-RING
O-RING
O-RING
GASKET
BOLT
BOLT
BOLT
BOLT
BOLT
BOLT
BOLT
BOLT
174
114
117
021
120
1
039
012
125
ASTM, AISI
CODE
NO. FOR
1 UNIT
CAST IRON
CAST IRON
CAST IRON
CAST IRON
420 STAINLESS
—
RUBBER (NBR)
RUBBER (NBR)
RUBBER (NBR)
RUBBER (NBR)
RUBBER (NBR)
RUBBER (NBR)
A48 Class 30
A48 Class 30
A48 Class 30
A48 Class 30
AISI420
304 STAINLESS
304 STAINLESS
304 STAINLESS
304 STAINLESS
304 STAINLESS
304 STAINLESS
304 STAINLESS
304 STAINLESS
AISI304
AISI304
AISI304
AISI304
AISI304
AISI304
AISI304
AISI304
1
1
1
1
1
1 SET
1
1
1
1
1
1
1
4
8
4
6
3
4
2
1
MATERIAL
PART
NO.
174
193-1
193-2
200
213
801
802
811-1
811-2
814
816
817
830
838-1
838-2
†849-1
†849-2
876
909
924-1
924-2
PART NAME
MATERIAL
DISCHARGE ELBOW
PLUG
PLUG
LIFTING HANGER
AIR VENT VALVE
ROTOR
STATOR
POWER CABLE
CONTROL CABLE
MOTOR COVER
BRACKET
BRACKET
SHAFT
WASHER
WASHER
BALL BEARING
BALL BEARING
MOTOR PROTECTOR
LEAKAGE DETECTOR
PACKING
PACKING
CAST IRON
304 STAINLESS
304 STAINLESS
STEEL
BRASS
—
—
—
—
CAST IRON
CAST IRON
CAST IRON
420J2 STAINLESS
304 STAINLESS
304 STAINLESS
—
—
—
—
RUBBER (NBR)
RUBBER (NBR)
ASTM, AISI
CODE
A48 Class 30
AISI304
AISI304
A283 Grade D
B36 No. 272
A48 Class 30
A48 Class 30
A48 Class 30
AISI420
AISI304
AISI304
NO. FOR
1 UNIT
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
3
1
1
1
Motors are purchased as a complete unit
†: Recommended spare parts
EBARA Fluid Handling
www.pumpsebara.com
(t) 803 327 5005 • (f) 803 327 5097
2-211
rev. 01/02
DLFU
EBARA Submersible Sewage Pumps
Sectional View
Project:
Model:
Chk’d:
Date:
15 to 30HP
817
115
5
838 924
1
1
811
1
120
8
200
811
2
924
2
838
2
115
4
115
6
849
2
120
7
876
830
814
801
909
802
115
3
849
1
120
4
120
6
193
2
120
5
115
1
816
2
213
115
2
816
1
005
174
120
2
117
193
1
120
1
120
3
012
001
125
PART
NO.
001
005
†012
†021
039
†111
†114
†115-1
†115-2
†115-3
†115-4
†115-5
†115-6
†117
120-1
120-2
120-3
120-4
120-5
120-6
120-7
120-8
125
PART NAME
CASING
INTERMEDIATE CASING
SUCTION COVER
IMPELLER
KEY
MECHANICAL SEAL
OIL SEAL
O-RING
O-RING
O-RING
O-RING
O-RING
O-RING
GASKET
BOLT
BOLT
BOLT
BOLT
BOLT
BOLT
BOLT
BOLT
BOLT
039 021
ASTM, AISI
CODE
NO. FOR
1 UNIT
CAST IRON
CAST IRON
CAST IRON
CAST IRON
420 STAINLESS
—
RUBBER (NBR)
RUBBER (NBR)
RUBBER (NBR)
RUBBER (NBR)
RUBBER (NBR)
RUBBER (NBR)
RUBBER (NBR)
A48 Class 30
A48 Class 30
A48 Class 30
A48 Class 30
AISI420
304 STAINLESS
304 STAINLESS
304 STAINLESS
304 STAINLESS
304 STAINLESS
304 STAINLESS
304 STAINLESS
304 STAINLESS
304 STAINLESS
AISI304
AISI304
AISI304
AISI304
AISI304
AISI304
AISI304
AISI304
AISI304
1
1
1
1
1
1 SET
1
1
1
1
1
1
1
1
4
8
4
6
6
3
6
2
1
MATERIAL
PART
NO.
174
193-1
193-2
200
213
801
802
811-1
811-2
814
816-1
816-2
817
830
838-1
838-2
†849-1
†849-2
876
909
924-1
924-2
114
111
PART NAME
MATERIAL
DISCHARGE ELBOW
PLUG
PLUG
LIFTING HANGER
AIR VENT VALVE
ROTOR
STATOR
POWER CABLE
CONTROL CABLE
MOTOR COVER
BRACKET
BRACKET
BRACKET
SHAFT
WASHER
WASHER
BALL BEARING
BALL BEARING
MOTOR PROTECTOR
LEAKAGE DETECTOR
PACKING
PACKING
CAST IRON
304 STAINLESS
304 STAINLESS
STEEL
BRASS
—
—
—
—
CAST IRON
CAST IRON
CAST IRON
CAST IRON
420J2 STAINLESS
304 STAINLESS
304 STAINLESS
—
—
—
—
RUBBER (NBR)
RUBBER (NBR)
ASTM, AISI
CODE
A48 Class 30
AISI304
AISI304
A283 Grade D
B36 No. 272
A48 Class 30
A48 Class 30
A48 Class 30
A48 Class 30
AISI420
AISI304
AISI304
NO. FOR
1 UNIT
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
3
1
1
1
Motors are purchased as a complete unit
†: Recommended spare parts
EBARA Fluid Handling
www.pumpsebara.com
(t) 803 327 5005 • (f) 803 327 5097
2-212
rev. 01/02
DLFU
EBARA Submersible Sewage Pumps
Sectional View
Project:
Model:
Chk’d:
Date:
40 to 60HP
100DLFU
838
1
924
1
811
1
120 811 924 838
8
2
2
2
200
115
7
115
5
115
6
817
849
2
120
7
801
876
802
814
120
6
115
4
830
120
4
816
2
816
1
193
1
849
1
120
5
115
3
909
120
3
193
2
115
2
111
115
1
005
114
213
120
2
001
021
039
174
080
117
125
167
107
120
1
PART
NO.
PART NAME
MATERIAL
CASING
001
CAST IRON
INTERMEDIATE CASING CAST IRON
005
IMPELLER
†021
CAST IRON
KEY
039
420 STAINLESS
BUSHING
080
304 STAINLESS
WEARING RING
†107
304 STAINLESS
MECHANICAL SEAL
†111
—
OIL SEAL
†114
RUBBER (NBR)
†115-1 O-RING
RUBBER (NBR)
†115-2 O-RING
RUBBER (NBR)
†115-3 O-RING
RUBBER (NBR)
†115-4 O-RING
RUBBER (NBR)
†115-5 O-RING
RUBBER (NBR)
†115-6 O-RING
RUBBER (NBR)
†115-7 O-RING
RUBBER (NBR)
GASKET
†117
120-1 BOLT
304 STAINLESS
120-2 BOLT
304 STAINLESS
120-3 BOLT
304 STAINLESS
120-4 BOLT
304 STAINLESS
120-5 BOLT
304 STAINLESS
120-6 BOLT
304 STAINLESS
120-7 BOLT
304 STAINLESS
120-8 BOLT
304 STAINLESS
Motors are purchased as a complete unit
†: Recommended spare parts
*: Option for hard-piped installations
EBARA Fluid Handling
www.pumpsebara.com
(t) 803 327 5005 • (f) 803 327 5097
ASTM, AISI
CODE
NO. FOR
1 UNIT
A48 Class 30
A48 Class 30
A48 Class 30
AISI420
AISI 304
AISI 304
1
1
1
1
1
1
1 SET
1
1
1
1
1
1
2
1
1
8
8
8
8
6
4
6
2
AISI304
AISI304
AISI304
AISI304
AISI304
AISI304
AISI304
AISI304
PART
NO.
125
*167
174
193-1
193-2
200
213
801
802
811-1
811-2
814
816-1
816-2
817
830
838-1
838-2
†849-1
†849-2
876
909
924-1
924-2
PART NAME
MATERIAL
BOLT
BASE
DISCHARGE ELBOW
PLUG
PLUG
LIFTING HANGER
AIR VENT VALVE
ROTOR
STATOR
POWER CABLE
CONTROL CABLE
MOTOR COVER
BRACKET
BRACKET
BRACKET
SHAFT
WASHER
WASHER
BALL BEARING
BALL BEARING
MOTOR PROTECTOR
LEAKAGE DETECTOR
PACKING
PACKING
304 STAINLESS
STEEL
CAST IRON
304 STAINLESS
304 STAINLESS
STEEL
BRASS
—
—
—
—
CAST IRON
CAST IRON
CAST IRON
CAST IRON
420J2 STAINLESS
304 STAINLESS
304 STAINLESS
—
—
—
—
RUBBER (NBR)
RUBBER (NBR)
ASTM, AISI
CODE
AISI304
A283 Grade D
A48 Class 30
AISI304
AISI304
A283 Grade D
B36 No. 272
A48 Class 30
A48 Class 30
A48 Class 30
A48 Class 30
AISI420
AISI304
AISI304
NO. FOR
1 UNIT
1
1
1
1
1
1
1
1
1
2
1
1
1
1
1
1
2
1
1 SET
1
3
1
2
1
2-213
rev. 01/02
DLFU
EBARA Submersible Sewage Pumps
Sectional View
Project:
Model:
40 to 60HP
150DLFU
200DLFU
250DLFU
300DLFU
838 924 811
817 115
6
1
1
1
Chk’d:
200
120 811
9
2
924
2
Date:
838
2
115
7
849
2
120
8
115
5
801
876
802
814
120
7
830
111
849
1
120
6
115
4
115
3
816
2
909
193
2
120
4
120
5
816
1
120
3
005
001
114
174
280
072
193
1
120
2
117
039
115
1
120
1
115
2
PART
NO.
001
005
†021
039
†072
†107
†111
†114
†115-1
†115-2
†115-3
†115-4
†115-5
†115-6
†115-7
†117
120-1
120-2
120-3
120-4
120-5
120-6
120-7
120-8
120-9
PART NAME
CASING
INTERMEDIATE CASING
IMPELLER
KEY
SIDE RING
WEARING RING
MECHANICAL SEAL
OIL SEAL
O-RING
O-RING
O-RING
O-RING
O-RING
O-RING
O-RING
GASKET
BOLT
BOLT
BOLT
BOLT
BOLT
BOLT
BOLT
BOLT
BOLT
021
107
167
125
ASTM, AISI
CODE
NO. FOR
1 UNIT
CAST IRON
CAST IRON
DUCTILE IRON
420 STAINLESS
CAST IRON
304 STAINLESS
—
RUBBER (NBR)
RUBBER (NBR)
RUBBER (NBR)
RUBBER (NBR)
RUBBER (NBR)
RUBBER (NBR)
RUBBER (NBR)
RUBBER (NBR)
A48 Class 30
A48 Class 30
A536 60-40-18
AISI420
A48 Class 30
AISI304
304 STAINLESS
304 STAINLESS
304 STAINLESS
304 STAINLESS
304 STAINLESS
304 STAINLESS
304 STAINLESS
304 STAINLESS
304 STAINLESS
AISI304
AISI304
AISI304
AISI304
AISI304
AISI304
AISI304
AISI304
AISI304
1
1
1
1
1
1
1 SET
1
1
1
1
1
1
2
1
1
3
/4
4
8
4
8
8
4
6
2
MATERIAL
PART
NO.
125
*167
174
193-1
193-2
200
280
801
802
811-1
811-2
814
816-1
816-2
817
830
838-1
838-2
†849-1
†849-2
876
909
924-1
924-2
PART NAME
MATERIAL
BOLT
BASE
DISCHARGE ELBOW
PLUG
PLUG
LIFTING HANGER
ELBOW SUPPORT
ROTOR
STATOR
POWER CABLE
CONTROL CABLE
MOTOR COVER
BRACKET
BRACKET
BRACKET
SHAFT
WASHER
WASHER
BALL BEARING
BALL BEARING
MOTOR PROTECTOR
LEAKAGE DETECTOR
PACKING
PACKING
304 STAINLESS
STEEL
CAST IRON
304 STAINLESS
304 STAINLESS
STEEL
STEEL
—
—
—
—
CAST IRON
CAST IRON
CAST IRON
CAST IRON
420J2 STAINLESS
304 STAINLESS
304 STAINLESS
—
—
—
—
RUBBER (NBR)
RUBBER (NBR)
ASTM, AISI
CODE
AISI304
A283 Grade D
A48 Class 30
AISI304
AISI304
A283 Grade D
A283 Grade D
A48 Class 30
A48 Class 30
A48 Class 30
A48 Class 30
AISI420
AISI304
AISI304
NO. FOR
1 UNIT
1
1
1
1
1
1
2
1
1
2
1
1
1
1
1
1
2
1
1 SET
1
3
1
2
1
Motors are purchased as a complete unit
†: Recommended spare parts
*: Option for hard-piped installations
EBARA Fluid Handling
www.pumpsebara.com
(t) 803 327 5005 • (f) 803 327 5097
2-214
rev. 02/09