2XY-J 2XY-O Application For power transmission and power distribution, generally for fixed underground installation in industrial plants and public building, electric stations and transforming plants, where mechanical damage is not anticipated. The cables are suitable for use in dry, wet and damp rooms. Technical data Cable design manufactured acc. to the technical specification TS 02-02-04 A of GAMAKABEL according to HD 603 rated voltage Uo/U: 0.6/1 kV test voltage: alternating voltage - 4 kV 12 insulation resistance at 90 °C: min 10 Ω x cm maximum conductor temperature: + 90 °C max.conductor temperature at short circuit for 5 s : +250 °C temperature of environment: -30 °C to +70 °C minimum temperature during installation: 0 °C minimum bending radius during installation: single core : 15D ; multiple core : 12D (D - outer cable diameter) flame test: flame-retardant acc. to IEC 60332-1 sheath colour – black Number of cores 2 3 4 5 above 5 copper conductors class 1 or class 2 according 2 to IEC 60228: class 1 for cross section 1,5 mm 2 2 to 16.0 mm ; class 2 for cross section 16 mm 2 to 95 mm insulation: cross-linked polyethylene type XLPE according to HD 603 inner covering - filling compound, compatible with other elements of cable sheath: PVC compound type DMV 6 according to HD 603 2XY-J - with protective conductor 2XY-O - without protective conductor Core identification in accordance to HD 308 S2 Cables without protective conductor Cables with protective conductor brown, blue brown, black, grey blue, brown, black, grey blue, brown, black, grey, black black with number code green-yellow, blue, brown green-yellow, brown, black, grey green-yellow, blue, brown, black, grey green-yellow, the other black with number code Conductor shape designation re - circular solid conductor rm - circular stranded conductor Number of Conductor Outer Conductors shape Diameter and Cross Section 2 No x mm mm 1 x 1,5 re 6,5 1 x 2,5 re 6,8 1 x 4,0 re 7,3 1 x 6,0 re 7,8 Copper Weight Cable Weight kg/km 14 24 39 58 kg/km 58 70 87 110 Number of Conductor Outer Conductors shape Diameter and Cross Section 2 No x mm mm 5 x 1,5 re 12 5 x 2,5 re 13 5 x 4,0 re 14 5 x 6,0 re 16 www.gamakabel.com Copper Weight Cable Weight kg/km 72 120 192 288 kg/km 230 294 385 504 2XY-J 2XY-O Number of Conductor Outer Conductors shape Diameter and Cross Section 2 No x mm mm 1 x 10 re 8,6 1 x 16 rm 10,1 1 x 25 rm 11,8 1 x 35 rm 12,9 1 x 50 rm 14,4 1 x 70 rm 16,4 1 x 95 rm 18,3 Copper Weight Cable Weight kg/km 96 154 240 336 480 672 912 kg/km 154 222 322 421 545 751 1007 2 x 1,5 2 x 2,5 2 x 4,0 2 x 6,0 2 x 10 2 x 16 2 x 25 re re re re re rm rm 10,3 11,0 11,9 12,9 14,5 17,4 20,6 29 48 77 115 192 307 480 151 185 231 290 405 599 877 3 x 1,5 3 x 2,5 3 x 4,0 3 x 6,0 3 x 10 3 x 16 3 x 25 re re re re re rm rm 10,7 11,5 12,5 13,5 15,2 18,4 21,8 43 72 115 173 288 461 720 170 211 270 346 494 736 1089 4 x 1,5 4 x 2,5 4 x 4,0 4 x 6,0 4 x 10 4 x 16 4 x 25 re re re re re rm rm 11,4 12,3 13,4 14,5 16,5 19,9 23,8 58 96 154 230 384 614 960 197 250 324 421 609 913 1363 Number of Conductor Outer Conductors shape Diameter and Cross Section 2 No x mm mm 5 x 10 re 18 5 x 16 rm 22 5 x 25 rm 26 Copper Weight Cable Weight kg/km 480 768 1200 kg/km 737 1113 1672 7 x 1,5 8 x 1,5 10 x 1,5 12 x 1,5 14 x 1,5 16 x 1,5 19 x 1,5 24 x 1,5 27 x 1,5 30 x 1,5 37 x 1,5 re re re re re re re re re re re 13 14 16 16 17 18 18 21 22 22 24 101 115 144 173 202 230 274 346 389 432 533 252 280 337 379 422 467 529 651 710 770 912 7 x 2,5 8 x 2,5 10 x 2,5 12 x 2,5 14 x 2,5 16 x 2,5 19 x 2,5 24 x 2,5 27 x 2,5 30 x 2,5 37 x 2,5 re re re re re re re re re re re 14 15 17 18 18 19 20 23 24 25 27 168 192 240 288 336 384 456 576 648 720 888 330 368 449 508 570 636 728 902 989 1079 1290 www.gamakabel.com
© Copyright 2026 Paperzz