Gelest, Inc. GELEST, INC. 11 East Steel Rd. Morrisville, PA 19067 Phone: (215) 547-1015 MATERIAL SAFETY DATA SHEET EMERGENCY TELEPHONE CHEMTREC: 1-800-424-9300 NAME USED ON LABEL: Gelest® OE 46.2 2-part Silicone Optical Encapsulant - PP2-OE46.2 CHEMICAL NAME: VINYL MODIFIED POLY(DIMETHYLSILOXANE) copolymer, with (part B) HYDRIDE FUNCTIONAL CROSSLINKER SYNONYMS: 2-PAT SILICONE ELASTOMER CHEMICAL FAMILY: SILICONE HMIS CODES HEALTH: 1 FLAMMABILITY: 1 REACTIVITY: 0 INGREDIENTS IDENTITY CAS NO. % TL PHENYL(CHLOROPHENYL)SILOXANE - DIMETHYLSILOXANE COPOLYMER, VINYLDIMETHYLSILOXANE TERMINATED 1627113-90-9 >97 not established Part A contains the following additional component SILICON DIOXIDE, AMORPHOUS, HEXAMETHYLDISILAZANE TREATED 68909-20-6 / 7631-86-9 20-30 not established Part B contains the following additional component polyPHENYL(DIMETHYLHYDROSILOXY)SILOXANE, HYDRIDE TERMINATED 68952-30-7 <10 not established OSHA PEL not established not established not established PHYSICAL DATA Boiling Point: >205°C Specific Gravity: 1.22 Vapor Density, air = 1: NA % volatiles:NA Molecular Weight: NA (mixture) Appearance & Color: Clear liquid Melting Point: <-60°C Vapor Pressure, 20°: <1mm Solubility in water: insoluble Evaporation rate: NA Viscosity: 1000-4000 cSt. FIRE & EXPLOSION DATA Flash Point, COC: 220°C (428°F) Autoignition Temp.: not determined Flammability Limits- LEL: NA UEL: NA Extinguishing Media: Water spray or fog, foam, carbon dioxide, dry chemical. Special Fire Fighting Procedures: Avoid eye and skin contact. Do not breathe fumes or inhale vapors. Unusual Fire and Explosion Hazards: Irritating fumes and organic acid vapors may develop when material is exposed to elevated temperatures or open flame. -1-(PP2-OE46.2) Abbreviations: ND: Not Determined, No Data; NA: Not Applicable; LD: Lethal Dose, LC: Lethal Concentration; H: hour; °: °C unless otherwise stated; mm: millimeters Hg, torr; PEL: permissible exposure level; TWA: time weighted average; TLV: threshold limit value; HMIS: Hazardous Material information System; CAS No.: Chemcial Abstract Service Registration Number Gelest, Inc. © 2008 Gelest, Inc. ENVIRONMENTAL INFORMATION Spill response: Sweep material and transfer to a suitable container for disposal. Recommended Disposal: Incinerate. Follow all chemical pollution control regulations. HEALTH HAZARD DATA Eye Contact: May cause immediate or delayed severe eye irritation. Skin contact: A single relatively short exposure causes no adverse effect. Several or prolonged exposures may cause mild irritation. Avoid Contact. Inhalation: No information available. Avoid inhalation. Oral Toxicity: not determined Inhalation Toxicity: not determined SUGGESTED FIRST AID EYES: In case of contact, immediately flush eyes with flowing water for at least 15 minutes. Get medical attention. SKIN: Flush with water, then wash with soap and water. INHALATION: Move exposed individual to fresh air. Administer oxygen if needed. Call a physician. INGESTION: Never give fluids or induce vomiting if patient is unconscious or having convulsions. To conscious individual give one full cup of water to dilute ingested material. Get medical attention. REACTIVITY DATA Stability: Stable in sealed containers under dry inert atmosphere. Conditions to avoid: Store away from alkalis, oxidizers, metal salts, precious metals. Hazardous decomposition products: Organic acid vapors and silicon dioxide. SPECIAL PROTECTION INFORMATION Ventilation: Local exhaust is recommended. Mechanical is recommended. Respiratory Protection: If exposure exceeds TLV, NIOSH approved organic vapor respirator. Eye and Face Protection: Chemical worker’s goggles. Do not wear contact lenses. Other Clothing and Equipment: Rubber, neoprene or nitrile gloves. An eyewash and emergency shower should be available. Launder clothing before reuse. -2-(PP2-OE46.2) Abbreviations: ND: Not Determined, No Data; NA: Not Applicable; LD: Lethal Dose, LC: Lethal Concentration; H: hour; °: °C unless otherwise stated; mm: millimeters Hg, torr; PEL: permissible exposure level; TWA: time weighted average; TLV: threshold limit value; HMIS: Hazardous Material information System; CAS No.: Chemcial Abstract Service Registration Number Gelest, Inc. © 2008 Gelest, Inc. OTHER PRECAUTIONS For research and industrial use only. Storage and Handling: Store in sealed containers. TRANSPORTATION DOT SHIPPING NAME: CHEMICALS, NOI DOT HAZARD CLASS: None required DOT LABEL: None required DOT ID No: None required Prepared by safety and environmental affairs MSDS ISSUE DATE PP2-OE46.2: 1/13/15 SUPERSEDES: 12/4/14 The information contained in this document has been gathered from reference materials and/or Gelest, Inc. test data and is to the best knowledge and belief of Gelest, Inc. accurate and reliable. Such information is offered solely for your consideration, investigation and verification. It is not suggested or guaranteed that the hazard precautions or procedures described are the only ones which exist. Gelest, Inc. makes no warranties, express or implied, with respect to the use of such information and assumes no responsibility therefore. Information on this safety data sheet is not intended to constitute a basis for product specifications. -3-(PP2-OE46.2) © 2015 Gelest Inc. Morrisville, PA 19067 Abbreviations: ND: Not Determined, No Data; NA: Not Applicable; LD: Lethal Dose, LC: Lethal Concentration; H: hour; °: °C unless otherwise stated; mm: millimeters Hg, torr; PEL: permissible exposure level; TWA: time weighted average; TLV: threshold limit value; HMIS: Hazardous Material information System; CAS No.: Chemcial Abstract Service Registration Number Gelest, Inc. © 2008
© Copyright 2026 Paperzz