Regulators GAS APPARATUS With pressure in a full Acetylene cylinder at 250 psig and a full oxygen cylinder at 2200 psig, a way is needed to lower cylinder pressures to desired working pressures for use in the torch. This is accomplished by using an adjustable pressure reducing regulator. The regulator also maintain a steady working pressure as the cylinder pressure drops from use. Oxygen and acetylene regulators connect differently to their cylinders so they can not be mixed up. Oxygen regulators have right hand threads and regulators for Acetylene and other fuel gases have left hand threads. . Air Liquide unique 410 CGA for acetylene provides added safety by making it impossible to connect a CGA 510 fuel gas regulator to an acetylene cylinder D-24 www.airliquide.ca Regulators Medium-duty single-stage regulators Blueshield 48 Series single-stage regulators are designed for medium-duty applications: GAS APPARATUS Models available for the following gas services: Acetylene, MAPP, LPG, Oxygen, Inert gases, Argon, Nitrogen, Carbon Dioxide, Air and Helium. BLU-HPR48FM320 ULC listed. BLU-LPR48A410 High pressure 2 1 Compact brass bar-stock body for durability 2 50 mm (2 in) diameter, dual scale gauges (psi and kPa) with threaded, Low pressure impact-resistant, polycarbonate windows 3 3 Color-coded adjusting knob provides visual identification of gas service for 1 operator safety GAUGE SCALES 1 2 3 4 5 HIGH PRESSURE kPa psig MAXIMUM INLET PRESSURE kPa psig 30 2,800 400 2,755 400 100 15 N/A 410 023 200 30 2,800 400 2,755 400 100 15 N/A 510 023 Acetylene 200 30 2,800 400 2,755 400 100 15 N/A 520 023 BLU-LPR48B510 MAPP, LPG 1 700 100 2,800 400 2,755 400 280 40 N/A 510 023 BLU-HPR48C540 Oxygen 1,400 200 28,000 4000 20,685 3000 700 100 N/A 540 022 BLU-HPR48C580 Inert Gases 2 1,400 200 28,000 4000 20,685 3000 700 100 N/A 580 032 BLU-HPR48FM580ARHE Argon/Helium flowmeter 28,000 4000 20,685 3000 N/A 0-42 0-90 580 032 4 BLU-HPR48FG580 2 Argon flowgauge 28,000 4000 20,685 3000 N/A 0-30 0-65 580 032 BLU-HPR48FM580N Nitrogen flowmeter 28,000 4000 20,685 3000 N/A 0-47 0-100 580 032 4 BLU-HPR48FM320 Carbon Dioxide flowmeter 28,000 4000 20,685 3000 N/A 0-33 0-70 320 5 032 4 BLU-HPR48FG320 3 Carbon Dioxide flowgauge 28,000 4000 20,685 3000 N/A 0-30 0-65 320 5 032 ITEM NUMBER GAS SERVICE BLU-LPR48A410 Acetylene 200 BLU-LPR48A510 Acetylene BLU-LPR48A520 LOW PRESSURE kPa psig MAXIMUM DELIVERY PRESSURE kPa psig FLOW RANGE @ 21°C (70°F) l/min scfh CGA CONNECTIONS INLET OUTLET Liquefied petroleum gas, propane, propylene etc. Argon, helium, nitrogen Do not remove outlet connection or replace with one of different orifice diameter. Calibration of flowgauge scale requires specific metering orifice diameter. Adapter BLU-01460014 CGA connection 320 requires a sealing washer to effect a leak-tight joint. D-25 1-800-817-7697 Regulators Heavy-duty single-stage regulators GAS APPARATUS Blueshield 60 and Classic Series single-stage regulators are designed for heavy-duty application: Models available: Acetylene, oxygen, inert gases, compressed air, carbon dioxide, hydrogen and nitrogen. BLU-104 BLU-HPR60C540 1 Solid brass bar-stock body with minimum internal volume for added security 2 Sintered bronze filters protect seat from foreign material 3 Flexible rubber diaphragm with nylon fabric reinforcement for sensitive pressure response 4 Inlet gland filter protects seat from particles 5 Field-replaceable high-pressure cartridge 6 Forged brass body and cap 7 Models are equipped with high-capacity, self-reseating pressure relief valves to protect regulator components in the event of excess pressure build-up. This patented feature results in no burst disks as commonly found on other manufacturer's equipment BLU-LPR60GL410 ULC listed. 6 High pressure High pressure Low pressure Low pressure 3 2 7 5 4 1 D-26 www.airliquide.ca Regulators GAUGE SCALES ITEM NUMBER GAS SERVICE LOW PRESSURE psig kPa Oxygen Oxygen BLU-LPR60A410 Acetylene 200 30 200 30 1,400 200 Gaugeless 28,000 MAXIMUM INLET PRESSURE kPa psig MAXIMUM DELIVERY PRESSURE kPa psig CGA CONNECTIONS INLET OUTLET 4000 20,685 3000 700 100 540 Contents indicator 20,685 3000 700 100 540 022 022 2,800 400 2,755 400 100 15 410 023 2,800 400 BLU-LPR60A510 Acetylene 2,755 400 100 15 510 023 BLU-LPR60GL410 Acetylene Gaugeless Contents indicator 2,755 400 100 15 410 023 BLU-LPR60GL510 Acetylene Gaugeless Contents indicator 2,755 400 100 15 510 023 BLU-HPR60B350 Hydrogen 40 350 023 BLU-HPR60B580 700 100 28,000 4000 20,685 3000 280 Inert Gases 1 700 100 28,000 4000 20,685 3000 280 40 580 032 BLU-HPR60C580 Inert Gases 1 1,400 200 28,000 4000 20,685 3000 700 100 580 032 BLU-HPR60B555 Nitrogen 700 100 28,000 4000 20,685 3000 280 40 555 032 BLU-HPR60C555 Nitrogen 1,400 200 28,000 4000 20,685 3000 700 100 555 032 BLU-HPR60D555 Nitrogen 4,200 600 28,000 4000 20,685 3000 2,100 300 555 † BLU-HPR60D580 Nitrogen 4,200 600 28,000 4000 20,685 3000 2,100 300 580 † BLU-HPR60B346 Compressed Air 700 100 28,000 4000 20,685 3000 280 40 346 033 BLU-HPR60C346 Compressed Air 1,400 200 28,000 4000 20,685 3000 700 100 346 033 BLU-HPR60B320 Carbon Dioxide 700 100 28,000 4000 20,685 3000 280 40 320 2 032 BLU-HPR60C320 Carbon Dioxide 1,400 200 28,000 4000 20,685 3000 700 100 320 2 032 GAS APPARATUS BLU-HPR60C540 BLU-HPR60GL540 HIGH PRESSURE kPa psig 1 Argon, helium, nitrogen. 2 CGA connection 320 requires a sealing washer to effect a leak-tight joint. † 1/4" SAE 45 ° flare fitting (CGA 165) GAUGE SCALES ITEM NUMBER GAS SERVICE LOW PRESSURE kPa psig HIGH PRESSURE kPa psig MAXIMUM INLET PRESSURE kPa psig MAXIMUM DELIVERY PRESSURE kPa psig CGA CONNECTIONS INLET OUTLET BLU-104 Oxygen 1,400 200 28,000 4000 20,685 3000 700 100 540 022 BLU-114 Acetylene 200 30 2800 400 2755 400 100 15 410 023 BLU-114P Acetylene 200 30 2800 400 2755 400 100 15 510 023 BLU-191 MAPP and fuel gases 700 100 N/A N/A 2755 400 400 60 510 023 D-27 1-800-817-7697 Regulators XPR1 regulators GAS APPARATUS • Blueshield Heavy-Duty XPR single-stage regulators are the preferred choice for high-pressure XPR cylinders with CGA 680 outlet connections and are not intended for use on manifold installations or bulk packs • Blueshield XPR Series single-stage regulators are used for MIG & TIG applications • Models available for inert gas service: Argon, Nitrogen, Arcal, Blueshield mixes BLU-XPR63FM2680 • Design features elongated nut and gland for easy installation on cylinders equipped with tulip caps ULC listed. Elongated inlet nut and gland for easy installation on cylinders equipped with tulip cap. High pressure Low pressure GAUGE SCALES 1 2 † MAXIMUM INLET PRESSURE kPa psig 200 40,000 6000 37,920 5500 700 600 2100 GAS SERVICE LOW PRESSURE kPa psig BLU-XPR63C680 Inert gases 2 1,400 2 4,200 BLU-XPR63D680 Inert gases BLU-XPR63FG680 Inert gases 2 BLU-XPR63FM680 Inert gases 2 BLU-XPR63FM2680 Inert gases 2 XPR is Air Liquide’s designation for extra-high pressure. Argon, nitrogen, Arcal and Blueshield mixtures. Adapter BLU-01460014 D-28 www.airliquide.ca MAXIMUM DELIVERY PRESSURE kPa psig HIGH PRESSURE kPa psig ITEM NUMBER FLOW RANGE @ 21°C (70°F) L/min scfh 100 N/A 300 N/A CGA CONNECTIONS INLET OUTLET 680 032 40,000 6000 37,920 5500 680 032 flowgauge 40,000 6000 37,920 5500 - 0-30 0-65 680 032 flowmeter 40,000 6000 37,920 5500 - 0-33 0-70 680 032 † dual flowmeter 40,000 6000 37,920 5500 - 0-33 0-70 680 032 † Regulators Heavy-duty double-stage regulators Blueshield TSR Series double-stage regulators are designed: GAS APPARATUS • To reduce cylinder gas pressure in two steps, allowing a constant delivery pressure to be maintained, regardless of cylinder pressure • Models are available for: Carbon dioxide, oxygen, acetylene, hydrogen, compressed air, argon/nitrogen/helium and nitrogen ULC listed. • All high-pressure models are equipped with high-capacity, self-reseating pressure relief valves to protect regulator components in the event of excess pressure build-up.This patented feature results in no burst disks as commonly found on other manufacturer's equipment • All pressures gauges are dual scaled (psi and kPa) with polycarbonate windows • Colour-coded pressure adjusting knobs provide visual identification of gas service for added safety • This feature makes double-stage regulators suited to applications where accuracy and consistency are a must. All double-stage regulators are based on a heavy-duty design that incorporate replaceable cartridges to allow for quick and easy maintenance and repair GAUGE SCALES MAXIMUM INLET PRESSURE kPa psig MAXIMUM DELIVERY PRESSURE kPa psig CGA CONNECTIONS INLET OUTLET ITEM NUMBER GAS SERVICE BLU-TSR65C320 Carbon Dioxide 1400 200 28,000 4000 20,685 3000 930 135 320 032 BLU-TSR65C540 Oxygen 1400 200 28,000 4000 20,685 3000 930 135 540 022 BLU-TSR65A410 Acetylene 200 30 2800 400 2755 400 100 15 410 023 BLU-TSR65A510 Acetylene 200 30 2800 400 2755 400 100 15 510 023 LOW PRESSURE psig kPa HIGH PRESSURE psig kPa BLU-TSR65C350 Hydrogen 1400 200 28,000 4000 20,685 3000 930 135 350 023 BLU-TSR65C346 Compressed Air 1400 200 28,000 4000 20,685 3000 930 135 346 033 BLU-TSR65C580 Argon/Nitrogen/Helium 1400 200 28,000 4000 20,685 3000 930 135 580 032 BLU-TSR65C555 Nitrogen 1400 200 28,000 4000 20,685 3000 930 135 555 032 D-29 1-800-817-7697 Regulators Heavy-duty pipeline station regulators GAS APPARATUS • Blueshield PSR Series pipeline station regulators are used to connect pipeline systems that transport gases to welding stations and to welding outlets where pipeline pressure is usually constant. Station regulators are only equipped with delivery pressure gauges • The Blueshield PSR Series is available for the a variety of gas services: Oxygen, Acetylene, Inert gases and Fuel gases. ULC listed. • The Blueshield PSR Series can be used for multi-torch applications • All high-pressure models are equipped with high-capacity, self-reseating pressure relief valves to protect regulator components in the event of excess pressure build-up. This patented feature results in no burst disks as commonly found on other manufacturer's equipment • All pressures gauges are dual scaled (psi and kPa) with polycarbonate windows • Colour-coded pressure adjusting knobs provide visual identification of gas service for added safety ITEM NUMBER GAS SERVICE kPa psig MAXIMUM INLET PRESSURE kPa psig GAUGE SCALES MAXIMUM DELIVERY PRESSURE kPa psig CGA CONNECTIONS INLET OUTLET BLU-PSR65C024B Oxygen 1,400 200 1,380 200 930 135 024 022 BLU-PSR65C024C Oxygen 1,400 200 1,380 200 930 135 024 024 BLU-PSR65A025B Acetylene 200 30 100 15 100 15 025 023 BLU-PSR65B025C Acetylene 200 30 100 15 100 15 025 025 BLU-PSR65B025 Fuel gases 700 100 1,380 200 480 135 025 023 BLU-PSR65C034 Inert 1,400 200 1,380 200 930 135 034 032 BLU-PSR65FM2034 Argon/CO2/Dual flowmeter N/A N/A 1,380 200 28 Ar/26 CO2 L/min 60 Ar/55 CO2 scfh 034 032 BLU-PSR65FM034 Argon/CO2/Flowmeter N/A N/A 1,380 200 28 Ar/26 CO2 L/min 60 Ar/55 CO2 scfh 034 032 D-30 www.airliquide.ca
© Copyright 2026 Paperzz