APPENDIX E MANUFACTURED/MOBILE HOME PARKS AND RECREATIONAL VEHICLE PARKS Part A Manufactured/Mobile Home (M/H) Park Definitions and General Requirements E 1 Manufactured/Mobile Home. A structure transportable in one (1) or more sections, which in the traveling mode is eight (8) body feet (2,438 mm) or more in width and forty (40) body feet (12,192 mm) or more in length or, when erected on site, is three hundred twenty (320) or more square feet (29.7 m2), and which is built on a permanent chassis, and designed to be used as a dwelling with or without a permanent foundation when connected to the required utilities. It includes the plumbing, heating, air conditioning, and electrical systems contained therein. For further clarification of definition, see Federal Regulation 24 CFR. E 1.1 Manufactured/Mobile Home Accessory Building or Structure. A building or structure that is an addition to or supplements the facilities provided to a M/H. It is not a selfcontained, separate, habitable building or structure. Examples are awnings, cabanas, ramadas, storage structures, carports, fences, windbreaks, or porches. E 2 Manufactured/Mobile Home Lot. A portion of a M/H park designed for the accommodation of one M/H and its accessory buildings or structures for the exclusive use of the occupants. E 3 Manufactured/Mobile Home Park. A parcel (or contiguous parcels) of land that has been so designated and improved that it contains two (2) or more M/H lots available to the general public for the placement thereon of M/H for occupancy. General E 4 The M/H park plumbing and drainage systems shall be designed and installed in accordance with the requirements of this appendix and the requirements of this code. E 5 Before any plumbing or sewage disposal facilities are installed or altered in any M/H park, duplicate plans and specifications shall be filed and proper permits obtained from the department or departments having jurisdiction. Plans shall show in detail: (A) Plot plan of the park drawn to scale, indicating elevations, property lines, driveways, existing or proposed buildings, and the sizes of M/H lots. (B) Complete specification and piping layout of proposed plumbing systems or alteration. (C) Complete specification and layout of proposed sewage disposal system or alteration. (D) The nature and extent of the work proposed, showing clearly that such work will conform to the provisions of this code. Part B Manufactured/Mobile Home Park Drainage System Construction E 6 Drainage Systems. A drainage system shall be provided in all M/H parks for conveying and disposing of all sewage. Wherever feasible, connection shall be made to a public system. All new improvements shall be designed, constructed, and maintained in accordance with applicable laws and regulations. Where the drainage lines of the M/H park are not connected to a public sewer, all proposed sewage disposal facilities shall be approved by the Authority Having Jurisdiction prior to construction. E 7 Material. Pipe and fittings installed underground in M/H park drainage systems shall be of material approved for the purpose. M/H lot drainage inlets and extensions to grade shall be of material approved for underground use within a building. E 8 Drainage (Sewage) Lines. All drainage (sewage) collection lines shall be located in trenches of sufficient depth to be free of breakage from traffic or other movements and shall be separated from the park water supply system as specified in this code. Drainage (sewage) lines shall have a minimum size and slope as specified in Tables E-1 and E-2. E 9 M/H Lot Drainage Inlet and Lateral. (A) Size. Each lot shall be provided with a drainage inlet not less than three (3) inches (76 mm) in diameter. (B) The lateral line from the inlet to the sewage drain line shall slope at least one-fourth (1/4) inch per foot (20.9 mm/m). All joints shall be watertight. 337 Appendix E 2007 CALIFORNIA PLUMBING CODE (C) All materials used for drainage connections between a M/H and the lot drainage inlet shall be semi-rigid, corrosion-resistant, nonabsorbent, and durable. The inner surface shall be smooth. drainage system shall be sized according to Table E-1 or as provided herein. Drainage laterals shall be not less than three (3) inches (76 mm) in diameter. (B) A park drainage system that exceeds the fixture unit loading of Table E-1 or in which the grade and slope of drainage pipe does not meet the minimum specified in Table E-2 shall be designed by a registered professional engineer. (D) Provision shall be made for plugging or capping the sewage drain inlet when a M/H does not occupy the lot. Surface drainage shall be diverted away from the inlet. The rim of the inlet shall extend not more than four (4) inches (102 mm) above ground elevation. E 12 M/H Drain Connector. (A) An M/H shall be connected to the lot drainage inlet by means of a drain connector consisting of approved pipe not less than Schedule 40, appropriate fittings and connectors, and not less in size than the M/H drainage outlet. An approved cleanout shall be provided between the M/H and the lot drainage inlet. The fitting connected to the lot drainage inlet shall be a E 10 Location of Lot Drain Inlet. Each lot drainage inlet shall be located in the rear third section and within four (4) feet (1,219 mm) of the proposed location of the M/H. E 11 Pipe Size. (A) Each M/H lot drainage inlet shall be assigned a waste loading value of twelve (12) drainage fixture units, and each park TABLE E-1 Drainage Pipe Diameter and Number of Fixture Units on Drainage System Size of Drainage Pipe Maximum Number Inches mm of Fixture Units 3 76 35 2* 51 4 102 256 8 203 2640 5 127 6 *Except six unit fixtures 8 428 152 10 720 254 12 4680 305 8200 TABLE E-2 Minimum Grade and Slope of Drainage Pipe Pipe Size Inches 2 3 4 5 338 Slope per 100 ft. (30.5 m) mm Inches mm 76 25 635 51 102 127 25 15 11 635 381 279 Pipe Size Inches mm 8 203 6 10 12 152 254 305 Slope per 100 ft. (30.5 m) Inches mm 8 203 3 76 4 3-1/2 102 89 MANUFACTURED/MH PARKS AND RV PARKS directional fitting to discharge the flow into the drainage inlet. (B) A drain connector shall be installed or maintained with a grade not less than onefourth (1/4) inch per foot (20.9 mm/m). A drain connector shall be gastight and no longer than necessary to make the connection between the M/H outlet and the drain inlet on the lot. A flexible connector may be used at the lot drainage inlet area only. Each lot drainage inlet shall be capped gastight when not in use. Part C M/H Park Water Supply E 13 General Requirements. An accessible and adequate supply of potable water shall be provided in each M/H park. Where a public supply of water of satisfactory quantity, quality, and pressure is available at or within the boundary of the park site, connection shall be made thereto and its supply used exclusively. When a satisfactory public water supply is not available, a private water supply system shall be developed and used as approved by the Authority Having Jurisdiction. E 14 Lot Service Outlet Size. Each M/H lot shall be provided with a water service outlet delivering potable water. The water service outlet riser shall be not less than three-fourths (3/4) inch (19.1 mm) nominal pipe size and capable of delivering twelve (12) water supply fixture units. E 15 Location of Water Service. Each lot water service outlet shall be located in the rear third section and within four (4) feet (1,219 mm) of the proposed location of the M/H. E 16 Pressure. Each M/H park water distribution system shall be so designed and maintained as to provide a pressure of not less than twenty (20) pounds per square inch (138 kPa) at each M/H lot at maximum operating conditions. E 17 Water Distribution Piping. Park water distribution systems shall be designed to deliver a minimum of twelve (12) water supply fixture units to each lot and installed with materials as set forth in Chapter 6 and/or Appendix A of this code. E 18 Shutoff Valve. A separate water shutoff valve shall be installed in each water service outlet at each M/H lot. Where a listed backflow protective device is installed, the service shutoff shall be located on the supply side of such device. Appendix E E 19 Backflow Preventer. Whenever a condition exists in the plumbing of a M/H that may create a cross-connection, a listed backflow preventer shall be installed in the water service line to the M/H at or near the water service outlet. When a hose bibb or outlet is installed on the supply outlet riser in addition to the service connector, a listed backflow preventer shall be installed on each additional outlet. E 20 Pressure-Relief Valve. Whenever it is required to install a backflow preventer at the M/H lot service outlet, a listed pressure-relief valve shall be installed in the water service line on the discharge side of the backflow preventer. Pressure-relief valves shall be set to release at a pressure not to exceed one hundred fifty (150) pounds per square inch (1,034 kPa). Pressurerelief valves shall discharge toward the ground. Backflow preventers and pressure-relief valves shall be at least twelve (12) inches (305 mm) above the ground. E 21 Mechanical Protection. All park water service outlets, backflow preventers, and pressure-relief valves shall be protected from damage by vehicles or other causes. Such protection may consist of posts, fencing, or other permanent barriers. E 22 M/H Water Connector. An M/H shall be connected to the park water service outlet by a flexible connector, such as copper tubing or other approved material not less than three quarter (3/4) inch nominal (19.1 mm) interior diameter. E 23 Water-Conditioning Equipment. (A) Permit Required. A permit shall be obtained from the Authority Having Jurisdiction prior to installing any waterconditioning equipment on an M/H lot. Approval of the park operator is required on all applications for a permit to install such equipment. If the water-conditioning equipment is of the regenerating type, and the park drainage system discharges into a public sewer, approval of the sanitary district or agency having jurisdiction over the public sewer is required. (B) Approval. Regenerating water-conditioning equipment shall be listed and labeled by an approved listing agency. (C) Installation. Regenerating units shall discharge the effluent of regeneration into a trap not less than one and one-half (1-1/2) inches (38 mm) in diameter connected to the 339 Appendix E 2007 CALIFORNIA PLUMBING CODE M/H park drainage system. An approved air gap shall be installed on the discharge line a minimum of twelve (12) inches (305 mm) above the ground. E 24 Testing. Installations shall be tested and inspected as required by Chapter 3 of this code. Part D Fuel Supply E 25 General. All fuel gas piping systems serving manufactured homes, accessory buildings, or structures and communities shall be designed and constructed in accordance with any applicable provisions of NFPA 54, National Fuel Gas Code, and NFPA 58, Liquefied Petroleum Gas Code. NFPA 31, Standard for the Installation of Oil-Burning Equipment, shall apply to oil fuel-burning systems and shall conform to the criteria of the Authority Having Jurisdiction. E 25.1 Gas Supply Connections. Gas supply connections at sites, where provided from an underground gas supply piping system, shall be located and arranged to permit attachment to a M/H occupying the site in a work-like manner. For the installation of liquefied petroleum gas (LPG) storage systems, the applicable provisions of NFPA 58, Liquefied Petroleum Gas Code, shall be followed. E 25.2 Location of Gas Supply Connection. The gas supply to the M/H shall be located within 4 feet (1.22 m) of the M/H stand. [NFPA 501A: Sections 4.3, 4.3.8, 4.4, and 4.4.5.] Exception: The above requirements shall not apply to gas supply connections for manufactured homes located on all-weather wood, concrete, or concrete block foundation systems or on foundations constructed in accordance with the local Building Code or, in the absence of a local code, with a recognized model building code. [NFPA 501A Section 4.1.3] E 26 Single and Multiple Manufactured Home Site Fuel Supply Systems. E 26.1 Gas Piping Installations. E 26.1.1 Gas Supply Connections – Underground Gas Piping. Gas supply connections at sites, where provided from an underground gas supply piping system, shall be located and arranged to permit attachment in a work-like manner 340 to a manufactured home occupying the site. For the installation of LPG storage systems, the provisions of NFPA 58, Liquefied Petroleum Gas Code, shall be followed. E 26.1.2 Underground gas piping system installations shall comply with any applicable Building Code and Sections E 26.1.2.1 and E 26.1.2.2. E 26.1.2.1 Underground gas piping shall not be installed beneath that portion of an M/H site reserved for the location of a manufactured home or M/H accessory building or structure unless installed in the open-ended gastight conduit of Section E 26.1.2.2. E 26.1.2.2 The open-ended gastight conduit shall conform to the following: (1) The conduit shall be not less than Schedule 40 pipe that is approved for underground installation beneath buildings. (2) The interior diameter of the conduit shall be not less than 0.5 inches (12.7 mm) larger than the outside diameter of the gas piping. (3) The conduit shall extend to a point not less than 4 inches (102 mm) beyond the outside wall of the M/H, accessory building, or structure, and the outer ends shall not be sealed. (4) Where the conduit terminates within a M/H, accessory building, or structure, it shall be readily accessible, and the space between the conduit and the gas piping shall be sealed to prevent leakage of gas into the building. E 27 Manufactured Home Site Gas Shutoff Valve. Each M/H site shall have a listed gas shutoff valve installed upstream of the M/H site gas outlet. The gas shutoff valve shall be located on the outlet riser at a height of not less than 6 inches (152 mm) above grade. A gas shutoff valve shall not be located under any M/H. The outlet shall be equipped with a cap or plug to prevent discharge of gas whenever the M/H site outlet is not connected to an M/H. Exception: All gas shutoff valves for manufactured homes located on foundations constructed in accordance with the local Building Code or, in the absence of a local code, with a recognized model building code. E 28 Gas Meters. E 28.1 Support of Meters. Where installed, gas MANUFACTURED/MH PARKS AND RV PARKS meters shall be adequately supported by a post or bracket placed on a firm footing or other means providing equivalent support and shall not depend on the gas outlet riser for support. E 28.2 Location of Meters. Each gas meter shall be installed in an accessible location and shall be provided with unions or other fittings so that the motor is removed easily and replaced in an upright position. Meters shall not be installed in unventilated or inaccessible locations or closer than 3 ft (0.91 m) to sources of ignition. E 28.3 Meter Shutoff Valve or Cock. All gas meter installations shall be provided with shutoff valves or cocks located adjacent to and on the inlet side of the meters. In the case of a single meter installation utilizing an LP-Gas container, the container service valve shall be permitted to be used in lieu of the shutoff valve or cock. All gas meter installations shall be provided with test tees located adjacent to and on the outlet side of the meters. E 29 Multiple Manufactured Home Site Fuel Distribution and Supply Systems. [NFPA 501A: Section 4.1, 4.3.11, 4.4, and 4.4.5.] E 30 Manufactured Home Community Natural Gas Distribution Systems. All underground metallic fuel piping systems shall comply with the cathodic protection requirements of 49 CFR 191 and 192. [NFPA 501A: Section 4.3.1] E 31 Manufactured Home Community LPG Supply Systems. Where 10 or more customers are served by one LPG supply system, the installation of the gas supply system shall be in accordance with 49 CFR 192, Transportation of Natural and Other Gas by Pipeline: Minimum Federal Safety Standards. Other liquefied petroleum gas supply systems and the storage and handling of LPG shall be in accordance with NFPA 58, Liquefied Petroleum Gas Code. [NFPA 501A: Section 4.3.8] E 32 Installation of Cathodic Protection Systems. Where required by the federal standard cited in NFPA 501A Section 2.3.1, cathodic protection shall be installed for corrosion control of buried or submerged metallic gas piping. [NFPA 501A: Section 4.3.6.1 and 4.3.6.2] E 33 Required Gas Supply. The minimum hourly volume of gas required at each M/H site outlet or any section of the M/H community gas piping system shall be calculated as shown in Table E 3. E 34 Gas Pipe Sizing and Pressure. E 34.1 The size of each section of a gas piping system shall be determined in accordance with NFPA 54, National Fuel Gas Code, or by other Appendix E standard engineering methods acceptable to the Authority Having Jurisdiction. E 34.2 Where all connected appliances are operated at their rated capacity, the supply pressure shall be not less than 4 ounces per square inch [7 in. water column (1,743 Pa)]. The gas supply pressure shall not exceed 8 ounces per square inch [14 in. water column (3,486 Pa)]. E 35 Gas Piping Materials. E 35.1 Metal. Metal gas pipe shall be standardweight wrought iron or steel (galvanized or black), yellow brass containing not more than 75 percent copper, or internally tinned or treated copper of iron pipe size. Galvanizing shall not be considered protection against corrosion. Seamless copper or steel tubing shall be permitted to be used with gases not corrosive to such material. Steel tubing shall comply with ASTM A 539, Standard Specification for ElectricResistance-Welded Coiled Steel Tubing for Gas and Fuel Oil Lines, or ASTM A 254, Standard Specification for Copper-Brazed Steel Tubing. Copper tubing shall comply with ASTM B 88, Specification for Seamless Copper Water Tubing (Type K or Type L), or ASTM B 280, Specification for Seamless Copper Tubing for Air Conditioning and Refrigeration Field Service. Copper tubing TABLE E-3 Demand Factors for Use in Calculating Gas Piping Systems in M/H Communities No. of Manufactured Home Sites 1 2 3 4 5 6 7 8 9 10 11–20 21–30 31–40 41–60 Over 60 Btu/h per Manufactured Home Site 125,000 117,000 104,000 96,000 92,000 87,000 83,000 81,000 79,000 77,000 66,000 62,000 58,000 55,000 50,000 Note: In extreme climate areas, additional capacities shall be considered. 341 Appendix E (unless tin-lined) shall not be used if the gas contains more than an average of 0.3 grains of hydrogen sulfide per 100 standard feet3 of gas. E 35.2 Protection Coatings for Metal Gas Piping. All buried or submerged metallic gas piping shall be protected from corrosion by approved coatings or wrapping materials. All gas pipe protective coatings shall be approved types, shall be machine applied, and shall conform to recognized standards. Field wrapping shall provide equivalent protection and is restricted to those short sections and fittings that are necessarily stripped for threading or welding. Risers shall be coated or wrapped to a point at least 6 inches (152 mm) above ground. E 35.3 Plastic. Plastic piping shall be used underground only and shall meet the requirements of ASTM D 2513, Thermoplastic Gas Pressure Pipe, Tubing, and Fittings, or ASTM D 2517, Reinforced Epoxy Resin Gas Pressure Pipe and Fittings, as well as the design pressure and design limitations of 49 CFR 192.123, and shall otherwise conform to the installation requirements thereof. E 36 Gas Piping Installations. E 36.1 Minimum Burial Below Ground Level and Clearances. All gas piping installed below ground level shall have a minimum earth cover of 18 inches (451 mm) and shall be installed with at least 12 inches (305 mm) of clearance in any direction from any other underground utility system. E 36.2 Metallic Gas Piping. E 36.2.1 All metallic gas piping systems shall be installed in accordance with approved plans and specifications, including provisions for cathodic protection. Each cathodic protection system shall be designed and installed to conform to the provisions of 49 CFR 192. E 36.2.2 Where the cathodic protection system is designed to protect only the gas piping system, the gas piping system shall be electrically isolated from all other underground metallic systems or installations. Where only the gas piping system is cathodically protected against corrosion, a dielectric fitting shall be used in the M/H gas connection to insulate the M/H from the underground gas piping system. E 36.2.3 Where a cathodic protection system is designed to provide all underground metallic systems and installations with 342 2007 CALIFORNIA PLUMBING CODE protection against corrosion, all such systems and installations shall be electrically bonded together and protected as a whole. E 36.3 Plastic Gas Piping. Plastic gas piping shall only be used underground and shall be installed with an electrically conductive wire for locating the pipe. The wire used to locate the plastic pipe shall be copper, not smaller in size than No. 18 AWG, with insulation approved for direct burial. Every portion of a plastic gas piping system consisting of metallic pipe shall be cathodically protected against corrosion. E 36.4 Gas Piping System Shutoff Valve. A readily accessible and identifiable shutoff valve controlling the flow of gas to the entire M/H community gas piping system shall be installed near the point of connection to the service piping or to the supply connection of an LPG container. E 37 Liquefied Petroleum Gas Equipment. LPG equipment shall be installed in accordance with the applicable provisions of NFPA 58, Liquefied Petroleum Gas Code. E 38 Oil Supply. The following three methods of supplying oil to an individual M/H site shall be permitted: (1) Supply from an outside underground tank (see Section 2.4.6) (2) Supply from a centralized oil distribution system designed and installed in accordance with accepted engineering practices and in compliance with NFPA 31,Standard for the Installation of Oil-Burning Equipment (3) Supply from an outside aboveground tank (see Section 2.4.6) E 38.1 Minimum Oil Supply Tank Size. Oil supply tanks shall have a minimum capacity equal to 20 percent of the average annual oil consumption. E 38.2 Oil Supply Connections – General. Oil supply connections at M/H stands, where provided from a centralized oil distribution system, shall be located and arranged to permit attachment in a work-like manner to a manufactured home utilizing the stand. The installation of such facilities shall meet the provisions of NFPA 31, Standard for the Installation of Oil-Burning Equipment, and particularly Section 3.8 thereof. E 39 Fuel Supply Systems Installation. E 39.1 Flexible Gas Connector. Each gas supply connector shall be listed for outside M/H use, shall be not more than 6 ft (1.83 m) in length, and shall have a capacity rating adequate MANUFACTURED/MH PARKS AND RV PARKS to supply the connected load. Exception: All gas supply connections for manufactured homes located on an allweather wood, concrete, or concrete block foundation system or on a foundation constructed in accordance with the local Building Code or, in the absence of a local code, with a recognized model building code. E 39.2 Use of Approved Pipe and Fittings of Extension. Where it is necessary to extend the M/H inlet to permit connection of the 6 foot (1.83 m) listed connector to the site gas outlet, the extension shall be of approved materials of the same size as the M/H inlet and shall be adequately supported at no more than 4 foot (1.22 m) intervals to the M/H. E 39.3 Mechanical Protection. All gas outlet risers, regulators, meters, valves, or other exposed equipment shall be protected against accidental damage. E 39.4 Special Rules on Atmospherically Controlled Regulators. Atmospherically controlled regulators shall be installed in such a manner that moisture cannot enter the regulator vent and accumulate above the diaphragm. Where the regulator vent is obstructed due to snow and icing conditions, shields, hoods, or other suitable devices shall be provided to guard against closing of the vent opening. E 39.5 Fuel Gas Piping Test. The M/H fuel gas piping system shall be tested only with air before it is connected to the gas supply. The M/H gas piping system shall be subjected to a pressure test with all appliance shutoff valves in their closed positions. E 39.5.1 The fuel gas piping test shall consist of air pressure at not less than 10inch water column or more than 14 inch water column [6 oz./in.2 to 8 oz./in.2 (2,490 Pa to 3,486 Pa)]. The system shall be isolated from the air pressure source and shall maintain this pressure for 10 minutes or more without perceptible leakage. Upon satisfactory completion of the test, the appliance valves shall be opened, and the gas appliance connectors shall be tested with soapy water or bubble solution while under the pressure remaining in the piping system. Solutions used for testing for leakage shall not contain corrosive chemicals. Pressure shall be measured with either a manometer, slope gauge, or gauge that is calibrated in either water inch or psi, with increments of either 1/10 inch (2.5 mm) Appendix E or 1/10 psi (0.6 kPa gauge), as applicable. Upon satisfactory completion of the test, the M/H gas supply connector shall be installed, and the connections shall be tested with soapy water or bubble solution. WARNING Do not overpressurize the fuel gas piping system. Damage to valves, regulators, and appliances can occur due to pressurization beyond the maximums specified. E 39.5.2 Gas appliance vents shall be visually inspected to ensure that they have not been dislodged in transit and are connected securely to the appliance. E 39.6 Oil Tanks. No more than one 660 gallon (2,500 L) tank or two tanks with aggregate capacity of 660 gallon (2,500 L) or less shall be connected to one oilburning appliance. Two supply tanks, where used, shall be cross-connected and provided with a single fill and single vent as described in NFPA 31, Standard for the Installation of OilBurning Equipment, and shall be on a common slab and rigidly secured one to the other. Tanks having a capacity of 660 gallon (2,500 L) or less shall be securely supported by rigid, noncombustible supports to prevent settling, sliding, or lifting. E 39.6.1 Oil supply tanks shall be installed in accordance with the applicable provisions of NFPA 31, Standard for the Installation of Oil-Burning Equipment. E 39.6.2 A tank with a capacity no larger than 60 gallon (230 L) shall be permitted to be a DOT-5 shipping container (drum) and so marked, or a tank meeting the provisions of UL 80, Steel Inside Tank for Oil Burner Fuel. Tanks other than DOT-5 shipping containers having a capacity of not more than 660 gallon (2,500 L) shall meet the provisions of UL 80. Pressure tanks shall be built in accordance with Section VIII, Pressure Vessels, ASME Boiler, and Pressure Vessel Code. E 39.6.3 Tanks, as described in Sections 2.4.6 and 2.4.6.2, that are adjacent to buildings shall be located not less than 10 feet (3.05 m) from a property line that is permitted to be built upon. E 39.6.4 Tanks with a capacity no larger than 660 gallon (2,500 L) shall be equipped with an open vent no smaller than 1.5-inch (38 mm) iron pipe size; tanks with a 500 343 Appendix E gallon (1900 L) or less capacity shall have a vent of 1.25-inch (32 mm) iron pipe size. E 39.6.5 Tanks shall be provided with a means of determining the liquid level. E 39.6.6 The fill opening shall be a size and in a location that permits ready filling without spillage. E 40 Manufactured Home Accessory Building Fuel Supply Systems. Fuel gas supply systems installed in a M/H accessory building or structure shall comply with the applicable provisions of NFPA 54, National Fuel Gas Code, and NFPA 58, Liquefied Petroleum Gas Code. Fuel oil supply systems shall comply with the applicable provisions of NFPA 31, Standard for the Installation of Oil-Burning Equipment. E 41 Community Building Fuel Supply Systems in Manufactured Home Communities. E 41.1 Fuel Gas Piping and Equipment Installations. Fuel gas piping and equipment installed within a permanent building in a M/H community shall comply with nationally recognized appliance and fuel gas piping codes and standards adopted by the Authority Having Jurisdiction. Where the state or other political subdivision does not assume jurisdiction, such fuel gas piping and equipment installations shall be designed and installed in accordance with the appropriate provisions of NFPA 54, National Fuel Gas Code, or NFPA 58, Liquefied Petroleum Gas Code. E 41.2 Oil Supply Systems in M/H Communities. Oil-burning equipment and installation within a M/H community shall be designed and constructed in accordance with the applicable codes and standards adopted by the Authority Having Jurisdiction. Where the state or other political subdivision does not assume jurisdiction, such installation shall be designed and constructed in accordance with the applicable provisions of NFPA 31, Standard for the Installation of Oil-Burning Equipment. E 41.3 Oil-Burning Equipment and Installation. Oil-burning equipment and installation within a building constructed in a M/H community in accordance with the local Building Code or a nationally recognized building code shall comply with nationally recognized codes and standards adopted by the Authority Having Jurisdiction. Where the state or other political subdivision does not assume jurisdiction, such oil-burning equipment and installation shall be 344 2007 CALIFORNIA PLUMBING CODE designed and installed in accordance with the appropriate provisions of NFPA 31, Standard for the Installation of Oil-Burning Equipment. E 41.4 Inspections and Tests. Inspections and tests for fuel gas piping shall be made in accordance with Chapters 1 and 12 of this Code. Part E Recreational Vehicle Parks Definitions and General Requirements E 42 Recreational Vehicle (RV). A vehicular-type unit primarily designed as temporary living quarters for recreational, camping, travel, or seasonal use, that either has its own motive power, or is mounted on or towed by another vehicle. The basic entities are camping trailer, fifthwheel trailer, motor home, park trailer, travel trailer, and truck camper. E 43 Recreational Vehicle Park. A plot of land upon which two (2) or more recreational vehicle sites are located, established, or maintained for occupancy by recreational vehicles of the general public as temporary living quarters for recreation or vacation purpose. E 44 Recreational Vehicle Site. Within a recreational vehicle park, a plot of ground intended for the accommodation of a recreational vehicle, a tent, or other individual camping unit on a temporary basis. E 45 General. All plumbing shall be installed in accordance with the plumbing codes of the Authority Having Jurisdiction and with this appendix. Part F Recreational Vehicle Park Toilet and Shower Facilities E 46 Toilets and urinals shall be provided at one (1) or more locations in every recreational vehicle park. They shall be convenient of access and shall be located within a five hundred (500) foot (152.4 m) radius from any recreational vehicle site not provided with an individual sewer connection. E 47 Facilities for males and females shall be appropriately marked. E 48 A minimum of one (1) toilet shall be provided for each sex up to the first twenty-five (25) sites. For each additional twenty-five (25) sites not provided with sewer connections, an additional toilet shall be provided. MANUFACTURED/MH PARKS AND RV PARKS E 49 The interior finish of walls shall be moisture resistant to a height of four (4) feet (1,219 mm) to facilitate washing and cleaning. E 50 The floors shall be constructed of material impervious to water and shall be easily cleanable. Any building having water-flush toilets shall be provided with a floor drain in the toilet room. This drain shall be provided with means to protect the trap seal as required by this code. E 51 If water-flush toilets are provided, an equal number of lavatories shall be provided for up to six (6) toilets. One additional lavatory shall be provided for each two (2) toilets when more than six (6) toilets are required. Each lavatory basin shall have a piped supply of potable water and shall drain into the drainage system. E 52 If separate facilities are provided for men and women, urinals shall be acceptable for no more than one-third (1/3) of the toilets required in the men’s facilities, except that one (1) urinal may be used to replace a toilet in a minimum park. Only individual stall or wall-hung types of urinals shall be installed. Floor-type trough units shall be prohibited. E 53 Toilets shall be of an approved, elongated bowl type and shall be provided with seats with open fronts. E 54 Each toilet shall be in a separate compartment and be provided with a door with a latch for privacy and a holder or dispenser for toilet paper. Dividing walls or partitions shall be at least five (5) feet (1,524 mm) high and shall be separated from the floor by a space not greater than twelve (12) inches (305 mm). E 55 Toilet compartments shall be not less than thirty (30) inches (762 mm) in width (no toilet shall be set closer than fifteen (15) inches (381 mm) from its center to a side wall) and there shall be not less than thirty (30) inches (762 mm) of clear space in front of each toilet. E 56 Each toilet room for women shall be provided with a receptacle for sanitary napkins. The receptacle shall be of durable, impervious, and readily cleanable material, and shall be provided with a lid. E 57 Each shower, if provided, shall have a floor area of thirty-six (36) inches by thirty-six (36) inches (914 mm x 914 mm) and shall be capable of encompassing a thirty (30) inch (762 mm) diameter circle and shall be of the individual type, and each shower area shall be visually screened from view, with a minimum floor area of thirty-six (36) by thirty-six (36) inches (914 mm x 914 mm) per shower. Each shall be provided with individual dressing areas screened from view and shall contain a minimum of one (1) clothing hook and stool (or equivalent bench area). Appendix E E 58 Each shower area shall be designed to minimize the flow of water into the dressing area and shall be connected to the drainage system by means of a properly vented and trapped inlet. Each such area shall have an impervious, skid-resistant surface; wooden racks (duck boards) over shower floors shall be prohibited. E 59 Every toilet building shall have a minimum ceiling height of seven (7) feet (2,134 mm) and, unless artificial light is provided, a window or skylight area equal to at least ten (10) percent of the floor area shall be provided. All doors to the exterior shall open outward, be self-closing, and shall be visually screened by means of a vestibule or wall to prevent direct view of the interior when the exterior doors are open. Such screening shall not be required on single toilet units. E 60 Every toilet room shall have permanent, nonclosable, screened opening(s), having a total area not less than five (5) percent of the floor area and opening directly to the exterior in order to provide proper ventilation. Listed exhaust fan(s), vented to the exterior, the rating of which in cubic feet per minute is at least twenty-five (25) percent of the total volume of the room(s) served, shall be considered as meeting the requirements of this subsection. All openable windows and vents to the outside shall be provided with fly-proof screens of not less than number sixteen (16) mesh. Part G Recreational Vehicle Park Potable Water Supply and Distribution E 61 Quality. The supply or supplies of water shall comply with the appropriate potable water standards of the state or local health authority or, in the absence thereof, with the Drinking Water Standard of the Federal Environmental Protection Agency. (See 42 CFR Part 72, subpart J.) E 62 Sources. Only water approved by a regulating agency shall be acceptable. Where an approved public water supply system is available, it shall be used. Where the park has its own water supply system, the components of the system shall be approved. A water supply system that is used on a seasonal basis shall be provided with means for draining. E 63 Prohibited Connections. The potable water supply shall not be connected to any nonpotable or unapproved water supply, nor be subjected to any backflow or back-siphonage. 345 Appendix E 2007 CALIFORNIA PLUMBING CODE E 64 Supply. The water supply system shall be designed and constructed in accordance with the following: (A) A minimum of twenty-five (25) gallons (94.6 L) per day per site for sites without individual water connections. (B) A minimum of fifty (50) gallons (189.3 L) per day per site for sites with individual water connections. (C) A minimum of fifty (50) gallons (189.3 L) per day per site if water-flush toilets are provided in rest rooms. E 65 Pressure and Volume. Where water is distributed under pressure to any individual site, the water supply system shall be designed to provide a minimum flow pressure of twenty (20) pounds per square inch (137.8 kPa) with a minimum flow of two (2) gallons (7.6 L) per minute at any outlet. The maximum pressure shall not exceed eighty (80) pounds per square inch (551 kPa). E 66 Outlets. Water outlets shall be convenient to access and, when not piped to individual RV sites, shall not be located farther than three hundred (300) feet (91.4 m) from any site. Provisions shall be made to prevent accumulation of standing water or the creation of muddy conditions at each water outlet. E 67 Storage Tanks. this code. This connection shall be equipped with a listed anti-siphon backflow prevention device. E 70 Drinking Fountains. If provided, drinking fountains shall be in conformance with the requirements of this code. Part I Recreational Vehicle Park Drainage System E 71 An adequate and approved drainage system shall be provided in all RV parks for conveying and disposing of all sewage. Where available, parks shall be connected to a public sewer system. E 72 Material. Pipe and fittings installed in the drainage system shall be of material listed, approved, and installed per this code. E 73 The minimum diameters of drainage laterals, branches, and mains serving RV sites shall be in accordance with the following table: Maximum Number of Recreational Vehicle Stands Served 5 Table E-4 Minimum Pipe Sizes Inches (ID) Nominal (mm) 3 76 36 4 102 440 8 203 71 5 127 Water storage tanks shall be constructed of impervious materials, protected against contamination, and provided with locked, watertight covers. Any overflow or ventilation openings shall be downfacing and provided with corrosion-resistant screening of not less than number twenty-four (24) mesh to prevent the entrance of insects and vermin. Water storage tanks shall not have direct connections to sewers. E 74 The sewer lines shall be located to prevent damage from vehicular traffic. E 75 Cleanouts shall be provided per Chapter 7 of this code. Recreational Vehicle Park Water Connections Recreational Vehicle Site Drainage System Inlet Part H for Individual Recreational Vehicles E 68 When provided, the water connections for potable water to individual recreational vehicle sites shall be located on the left rear half of the site (left side of RV) within four (4) feet (1,219 mm) of the stand. E 69 Each potable water connection shall consist of a water riser pipe that shall be equipped with a threaded male spigot located at least twelve (12) inches (305 mm) but not more than twenty-four (24) inches (610 mm) above grade level for the attachment of a standard water hose. The water riser pipe shall be protected from physical damage per 346 120 6 152 Part J E 76 When provided, the site drainage system inlet connections for individual RVs shall be located so as to prevent damage by the parking of RVs or automobiles and shall consist of a sewer riser extending vertically to grade. The minimum diameter of the sewer riser pipe shall be three (3) inches (76 mm), and it shall be provided with a four (4) inch (102 mm) inlet or a minimum three (3) inch (76 mm) female fitting. E 77 When provided, the sewer inlet to individual RV sites shall be located on the left rear half of the site (left side of the RV) within four (4) feet (1,219 mm) of the stand. MANUFACTURED/MH PARKS AND RV PARKS E 78 The sewer riser pipe shall be firmly imbedded in the ground and protected against damage from movement. It shall be provided with a tight-fitting plug or cap, which shall be secured by a durable chain (or equivalent) to prevent loss. Part K Recreational Vehicle Park Sanitary Disposal Stations E 79 One (1) RV sanitary disposal station shall be provided for each one hundred (100) RV sites, or part thereof, which are not equipped with individual drainage system connections. E 80 Each station shall be level and convenient of access from the service road and shall provide easy ingress and egress for recreational vehicles. E 81 Construction. Unless other approved means are used, each station shall have a concrete slab with the drainage system inlet located so as to be on the road (left) side of the recreational vehicle. The slab shall be not less than three (3) feet by three (3) feet (914 mm x 914 mm), at least three and one-half (3-1/2) inches (89 mm) thick and properly reinforced. The slab surface is to be troweled to a smooth finish and sloped from each side inward to a drainage system inlet. The drainage system inlet shall consist of a four (4) inch (102 mm) self-closing, foot-operated hatch of approved material with the cover milled to fit tight. The hatch body shall be set in the concrete of the slab with the lip of the opening flush with its surface to facilitate the cleansing of the slab with water. The hatch shall be properly connected to a drainage system inlet, which shall discharge to an approved sanitary sewage disposal facility. Appendix E (2) feet by two (2) feet (610 mm x 610 mm) in size. Inscribed thereon in clearly legible letters shall be the following: DANGER – NOT TO BE USED FOR DRINKING OR DOMESTIC PURPOSES. Part L Recreational Vehicle Park Water Supply Stations E 83 A potable watering station, if provided for filling recreational vehicle potable water tanks, shall be located at least fifty (50) feet (15,240 mm) from a sanitary disposal station. When such is provided, adjacent to the potable water outlet shall be posted a sign of durable material not less than two (2) feet by two (2) feet (610 mm by 610 mm) in size. Inscribed thereon in clear legible letters on a contrasting background shall be: POTABLE WATER. NOT TO BE USED FOR FLUSHING WASTE TANKS. The potable water shall be protected from backflow by means of a listed vacuum breaker located downstream from the last shutoff valve. Part M Recreational Vehicle Park Fuel Gas Equipment and Installations E 84 All fuel gas equipment and installations shall comply with Part D of this appendix, except as otherwise permitted or required by this code. E 82 Where the recreational vehicle park is provided with a piped water supply system, means for flushing the recreational vehicle holding tank and the sanitary disposal station slab shall be provided and shall consist of a piped supply of water under pressure, terminating in an outlet located and installed so as to prevent damage by automobiles or recreational vehicles. The flushing device shall consist of a properly supported riser terminating at least two (2) feet (610 mm) above the ground surface, with a three-fourth (3/4) inch (19.1 mm) valved outlet adaptable for a flexible hose. The water supply to the flushing device shall be protected from backflow by means of a listed vacuum breaker or backflow prevention device located downstream from the last shutoff valve. Adjacent to the flushing arrangement shall be posted a sign of durable material not less than two 347 Appendix E 348 2007 CALIFORNIA PLUMBING CODE
© Copyright 2026 Paperzz