Cooling Fans Ambient Temperature: 14˚F to 140˚F (10˚C to 60˚C) Operating Voltage Range: 15% MDE Series Long-Life Models Materials Frame: Die Cast Aluminum Blades: Resin Flammability Grade: V-0 Overheat Protection: Built-in Overheat Protection Circuit Bearings: Ball Bearings 4.69 in.1.00 in. thick ( 119 mm25.4 mm thick) 100,000 hour life expectancy lowers maintenance costs and reduces downtime. More than 90% of fans satisfy the following criteria when operating at an ambient temperature of 140°F (60°C) : ● Rotation Speed (at rated voltage) Less than 30% below rated speed ● Input Current (at rated speed) Less than 30% above rated current Using these fans at a temperature of 95°F (35°C) or more and relative humidity of 25% or more may reduce their life expectancy. RrDC Specifications Speed Type Stall Alarm, Standard Speed r/min CFM m3/min inH2O Pa Noise Level dB(A) MDE1225-12L 12 0.58 3000 95.3 2.7 0.281 70 46 MDE1225-24L 24 0.30 3000 95.3 2.7 0.281 70 46 ●How to read the specifications➝Page E-13 ●Alarm Specifications: q➝Page E-14 0.30 70 3000 60 2500 50 0.20 2000 40 0.15 1500 30 20 500 10 0 0 Measured at a distance of 3.3 feet (1 m) from the fan intake side 50 3500 1000 Frequency — Audible Noise Level (dB) Speed 0.25 Noise Level [dB] 80 ●Details of safety standards➝Page G-2 60 Static Pressure [inH2O] Static Pressure [Pa] Speed [r/min] Air Flow — Static Pressure Characteristics 40 30 20 10 0 Static Pressure 0.10 31.5 63 125 250 500 1 k 1/3 Octave Band 2k 4k 8 k 16 k Center Frequency [Hz] 0.05 0 20 0 E-44 Max. Static Pressure Current A Electronic Alarm Type Speed 4000 Max. Air Flow Voltage VDC Model 0.5 40 1.0 60 1.5 80 100 120 Air Flow [CFM] 2.0 2.5 3.0 Air Flow [m3/min] System Configuration E-19 Accessories E-101 Cooling Fans Dimensions Scale 1/4, Unit = inch (mm) Weight: 0.66 lb. (0.3 kg) d E020 1.00 4.1260.012 (104.80.3) 0.157 (25.4) 0.157 (4) (4) AIR FLOW ROTATION Introduction 4.1260.012 (104.80.3) 4.69 (119) Rotation MRS Air Flow 0 0. 169 (4.3) 8 Holes ) ( 10 00) (3 12 MU 5 4.126 (104.8) 4.57 (116) .3 4 .5 1 7( 16 ) MBD 0.177 (4.5) 4 Holes Accessories (Sold Separately) Item 12 VDC or 24 VDC GND Alarm Output Model Safety Standards Page FG12D ✽ E-102 Filter FL12 / E-106 Screen FS12 / E-107 Finger Guard ✽ These products have been designed to pass tests set forth under the UL and CSA standards for equipment used in fans. They conform to the standards only when used with an O. Thermostats Accessories Red Black Orange MFD Connection Diagram MF Intake side Outlet side Centrifugal Blowers Cross Flow Fans AC Input DC Input AC Input DC Input ) 36 1 5( 0.177 (4.5) 4 Holes 4.126 (104.8) MB 4.126 (104.8) 4.126 (104.8) Unit = inch (mm) DC Input 4.57 (116) Long Life MDE MDS MD Panel Cut-Out Axial Flow Fans AC Input 9 .3 Variable Flow UL Style 1007 AWG 24 Leads (Red, Black) Alarm Lead (Orange) (Alarm Type Only) Before Using a Fan Finger Guard ● A filter or screen can be installed in place of the finger guard. E-45
© Copyright 2026 Paperzz