EFB 80 x 80 x 25.4 MM SERIES DIMENSIONS DRAWING UNIT: P & Q CURVE (AT RATED VOLTAGE) * Bearing Type MODEL PART NO. EFB0805L EFB0812L EFB0824L EFB0848L EFB0805M EFB0812M EFB0824M EFB0848M EFB0805H EFB0812H EFB0824H EFB0848H EFB0805HH EFB0812HH EFB0824HH EFB0848HH EFB0812VH EFB0824VH EFB0848VH EFB0812SH EFB0824SH EFB0848SH EFB0812EH EFB0824EH EFB0848EH FUNCTION -R00 / -F00 -R00 / -F00 -R00 / -F00 -R00 / -F00 -R00 / -F00 -R00 / -F00 -R00 / -F00 -R00 / -F00 -R00 / -F00 -R00 / -F00 -R00 / -F00 -R00 / -F00 -R00 / -F00 -R00 / -F00 -R00 / -F00 -R00 / -F00 -R00 / -F00 -R00 / -F00 -R00 / -F00 -R00 / -F00 -R00 / -F00 -R00 / -F00 -R00 / -F00 -R00 / -F00 -R00 / -F00 9.0 0.30 7.5 0.24 6.0 0.18 4.5 OUTLET SIDE INLET SIDE EH SH VH HH H M 0.12 3.0 0.06 1.5 0 0 (mm H2O) Air Pressure MOUNTING PANEL CUTOUT EFB0805/12/24/48X 0.36 (IN H2O) Ball Bearings * Material Impeller & Frame : Plastic (UL 94V-0) * Lead Wires : UL 1007 AWG #24 Or Equivalent Red Wire Positive (+) Black Wire Negative (-) * Weight : 86g (3.03 oz) mm (INCH) L 0 0.4 0 16.0 0.8 1.2 32.0 1.6 48.0 3 2.0 (M /MIN) 64.0 (CFM) UNIT: Air Flow Rated Voltage Operating Voltage Range Rated Current Rated Input Power VDC 5 12 24 48 5 12 24 48 5 12 24 48 5 12 24 48 12 24 48 12 24 48 12 24 48 VDC 4.5 to 5.5 7.0 to 13.8 14.0 to 27.6 28.0 to 56.0 4.5 to 5.5 7.0 to 13.8 14.0 to 27.6 28.0 to 56.0 4.5 to 5.5 7.0 to 13.8 14.0 to 27.6 28.0 to 56.0 4.5 to 5.5 7.0 to 13.8 14.0 to 27.6 28.0 to 56.0 7.0 to 13.8 14.0 to 27.0 28.0 to 56.0 7.0 to 13.8 14.0 to 27.0 28.0 to 56.0 7.0 to 13.8 14.0 to 27.0 28.0 to 56.0 Amp 0.16 0.07 0.04 0.03 0.20 0.09 0.05 0.03 0.24 0.10 0.05 0.04 0.30 0.13 0.07 0.04 0.15 0.08 0.05 0.22 0.11 0.06 0.28 0.14 0.07 Watt 0.80 0.84 0.96 1.44 1.00 1.08 1.20 1.44 1.20 1.20 1.20 1.92 1.50 1.56 1.68 1.92 1.80 1.92 2.40 2.64 2.64 2.88 3.36 3.36 3.36 Speed Maximum Air Flow Maximum Air Pressure Noise R.P.M. m3 /min 2700 0.783 27.65 2.89 0.114 27.5 3000 0.872 30.79 3.54 0.139 29.5 3250 0.940 33.20 4.08 0.161 31.5 3600 1.043 36.83 4.97 0.196 34.0 4000 1.154 40.75 5.99 0.236 37.5 4500 1.310 46.26 7.49 0.295 40.0 5000 1.473 52.02 8.94 0.352 42.5 CFM mmH 2 O IN H 2 O mm (INCH) dB-A * Function type is optional. * The max. air flow and the speed are measured in free air ; max. air pressure is measured at zero air flow. * Noise is measured in anechoic chamber in free air, one meter from intake side. * All readings are typical values at rated voltage. 29 * Specifications are subject to change without notice. http://www.deltaww.com
© Copyright 2026 Paperzz