General Installation Instructions LED • To reduce the risk of death, personal injury or property damage from fire, electric shock, falling parts, cuts/abrasions and other hazards, please read all warnings and instructions included with and on the luminaire box and all luminaire labels. • Before installing, servicing or performing routine maintenance upon this equipment, follow these general precautions. • Installation and service of luminaires should be performed by a qualified licensed electrician. • Maintenance of the luminaires should be performed by person(s) familiar with the luminaires’ construction and operation and any hazards involved. Regular luminaire maintenance programs are recommended. • It will occasionally be necessary to clean the outside of the refractor/lens. Frequency of cleaning will depend on ambient dirt level and minimum light output which is acceptable to user. Refractor/lens should be washed in a solution of warm water and any mild, nonabrasive household detergent, rinsed with clean water and wiped dry. Should optical assembly become dirty on the inside, wipe refractor/ lens and clean in above manner, replacing damaged gaskets as necessary. • DO NOT INSTALL DAMAGED PRODUCT! This luminaire has been properly packed so that no parts should have been damaged during transit. Inspect to confirm. Any part damaged or broken during or after assembly should be replaced. • Recycle: For information on how to recycle LED electronic products, please visit www.epa.gov. • These instructions do not purport to cover all details or variations in equipment nor to provide every possible contingency to meet in connection with installation, operation or maintenance. Should further information be desired or should particular problems arise which are not covered sufficiently for the purchaser’s or owner’s purposes, this matter should be referred to Acuity Brands Lighting, Inc., a parent company of Peerless Lighting. WARNING RISK OF ELECTRIC SHOCK 4Disconnect or turn off power before installation or servicing. 4Verify that supply voltage is correct by comparing it with the luminaire label information. 4Make all electrical and grounded connections in accordance with the National Electrical Code (NEC) and any applicable local code requirements. 4All wiring connections should be capped with UL approved recognized wire connectors. 4To prevent luminaire row from over-current: By adding the input current of each luminaire section marked on the luminaire, the total current per power feed must not exceed the maximum line wire amperage marked on the luminaire and the power feed cord/wire amperage rating whichever the least. WARNING RISK OF BURN 4Allow lamp/luminaire to cool before handling. Do not touch enclosure or light source. 4Do not exceed maximum wattage marked on luminaire label. 4Follow all manufacturer’s warnings, recommendations and restrictions for: driver type, burning position, mounting locations/methods, replacement and recycling. Part Number: PIN004102 Description: “INSTR, IMPORTANT SAFETY LED” Revision: C Effective Date: 07/2012 ECO3665 page 1 of 2 2246 5th Street, Berkeley, CA 94710 • Tel: 510.845.2760 • Fax: 510.845.2776 • Email: [email protected] • PeerlessLighting.com © 2014 Acuity Brands Lighting, Inc. All Rights Reserved. “Peerless” is a registered trademark of Acuity Brands Lighting. Products in this document may be covered by one or more U.S. Patents and Patents Pending. Specifications subject to change without notice. Limited warranty applies. Complete warranty terms located at www.AcuityBrands.com/CustomerResources/Terms_and_Conditions.aspx General Installation Instructions LED A General Installation Instructions LED CAUTION RISK OF INJURY CAUTION RISK OF FIRE 4Wear gloves and safety glasses at all times when removing luminaire from carton, installing, servicing or performing maintenance. 4Avoid direct eye exposure to the light source while it is on. 4Keep combustible and other materials that can burn away from lamp/lens. 4Do not operate in close proximity to persons, combustible materials or substances affected by heat or drying. CAUTION RISK OF PRODUCT DAMAGE 4Never connect components under load. 4Do not mount or support these luminaires in a manner that can cut the outer jacket or damage wire insulation. 4Unless individual product specifications deem otherwise: Never connect an LED product directly to a dimmer packs, occupancy sensors, timing devices, or other related control devices. LED luminaires must be powered directly off a switched circuit. 4Unless individual product specifications deem otherwise: Do not restrict luminaire ventilation. Allow for some volume of airspace around luminaire. Avoid covering LED luminaires with insulation, foam or other material that will prevent convection or conduction cooling. 4Unless individual product specifications deem otherwise: Do not exceed luminaire’s maximum ambient temperature. 4Only use luminaire in its intended location. 4LED products are polarity sensitive. Ensure proper polarity before installation. 4Electrostatic Discharge (ESD): ESD can damage LED fixtures. Personal grounding equipment must be worn during all installation or servicing of the unit. 4Do not touch individual electrical components as this can cause ESD, shorten lamp life or alter performance. 4Some components inside the luminaire may not be serviceable. In the unlikely event your unit may require service, stop using the unit immediately and contact a Peerless Lighting representative for assistance. 4Always read the fixtures complete installation instructions prior to installation for any additional luminaire specific warnings. SAVE THESE INSTALLATION INSTRUCTIONS Please see product specific installation instructions for additional warnings or any applicable FCC or other regulatory statements. Failure to follow any of these instructions could void product warranties. For a complete listing of product Terms and Conditions, please visit PeerlessLighting.com. Peerless Lighting, an Acuity Brands Company, assumes no responsibility for claims arising out of improper or careless installation or handling of its products. Part Number: PIN004102 Description: “INSTR, IMPORTANT SAFETY LED” Revision: C Effective Date: 07/2012 ECO3665 page 2 of 2 2246 5th Street, Berkeley, CA 94710 • Tel: 510.845.2760 • Fax: 510.845.2776 • Email: [email protected] • PeerlessLighting.com © 2014 Acuity Brands Lighting, Inc. All Rights Reserved. “Peerless” is a registered trademark of Acuity Brands Lighting. Products in this document may be covered by one or more U.S. Patents and Patents Pending. Specifications subject to change without notice. Limited warranty applies. Complete warranty terms located at www.AcuityBrands.com/CustomerResources/Terms_and_Conditions.aspx General Installation Instructions LED B Peerless Mino 1x4 Recessed INSTALLATION INSTRUCTIONS PIN006300 Rev. B 08/20/14 ECO3715 MN9 These installation instructions are used for installing the following luminaires and kits: Luminaire Mounting Kit MN9 1x4 G or ST LATC / FLNGW WARNING: Please read the “important safety instructions” prior to installation of this product. A) Identification of MN9 1x4 Luminaire ………………………………………………………………………… Page 1 B) 1x4 Recessed Luminaire Installation ..……………………………………………………………………… Page 2 C) Drywall Grid Adapter Option (FLNGW) ………...…………………………………………………………... Page 3 D) Lens Care Instructions ...…………………………..…………………………………………………………. Page 3 A) Identification of MN9 1x4 Luminaire Luminaire Components 1 PIN005702 Rev. B 08/20/14 ECO3715 MN9 B) 1x4 Recessed Luminaire Installation 1 Remove access plate. Run power cord from junction box to luminaire, knocking out one hole in access plate to pass cord through. Perform wire splices and insert wires back into the luminaire. PIN000000 Rev. X 00/00/00 ECO0000 2 3 XXX Use ground screw on access plate to ground luminaire. Replace access plate. Ensure that extended and hanging brackets are in the correct position for the type of grid used. Use alternate holes in the extended and hanging brackets if necessary. 4 5 6 Install luminaire into ceiling by resting the four extended brackets onto the ceiling grid. Attach provided LATC clips on each mounting bracket loosely. Adjust clips vertically to engage with “T” member and tighten screws. Complete support to structure using cables attached to LATC clips. Peel away lens cover after luminaire is fully installed. 2 PIN005702 Rev. B 08/20/14 ECO3715 MN9 C) Drywall Grid Adapter Option (FLNGW) for Sheet Rock Ceilings (5/8” Thick) Minimum Ceiling Clearance = 10” ‘L’ bracket (4X) 1 2 Drywall screws Holes for guide wires to structure 3 PIN000000 Rev. X 00/00/00 ECO0000 Sheet rock Guide wires to structure (4X) (by others) CONTRACTOR TO SPAKLE, FEATHER AND SAND TRIM #6 screws (4X) APPROX ½” Drywall grid adapter kit comes assembled with #6 screws (4X) and “L” brackets (4X) as illustrated above. 4 XXX Conduit (by others) Fasten sheet rock into aluminum extrusion frame using drywall screws. Drywall grid adapter is designed for 5/8” sheetrock, so allow approximately 1/16” for mudding and blending to finish ceiling. Make sure that the frame is square and tight against the ceiling. Ensure guide wires (by others) to structure (by others) are properly secured. 5 6 Ground screw Remove access plate. Run power cord from junction box to luminaire, knocking out one hole in access plate to pass cord through. Perform wire splices and insert wires back into the luminaire. 7 Luminaire rests SECURELY on four sides Ensure the luminaire rests securely on drywall kit with brackets on all four sides Use ground screw on access plate to ground luminaire. Replace access plate. Insert luminaire into ceiling through the drywall kit. 8 9 From above, completed installation should look like this picture. Peel away lens cover after luminaire is fully installed. D) Lens Care Instructions Once installed, if the Peerless Mino lens needs to be removed for any reason, wear cotton gloves to protect against fingerprints. Clean lenses with soft cloth. Dampen cloth with water if needed. When reaffixing the lens, push the lens up from the center so that it is flat against the housing before retightening the thumbscrews. 3
© Copyright 2026 Paperzz