General Installation Instructions
LED
• To reduce the risk of death, personal injury or property damage from fire, electric shock, falling parts, cuts/abrasions and other hazards,
please read all warnings and instructions included with and on the luminaire box and all luminaire labels.
• Before installing, servicing or performing routine maintenance upon this equipment, follow these general precautions.
• Installation and service of luminaires should be performed by a qualified licensed electrician.
• Maintenance of the luminaires should be performed by person(s) familiar with the luminaires’ construction and operation and any hazards
involved. Regular luminaire maintenance programs are recommended.
• It will occasionally be necessary to clean the outside of the refractor/lens. Frequency of cleaning will depend on ambient dirt level and
minimum light output which is acceptable to user. Refractor/lens should be washed in a solution of warm water and any mild, nonabrasive household detergent, rinsed with clean water and wiped dry. Should optical assembly become dirty on the inside, wipe refractor/
lens and clean in above manner, replacing damaged gaskets as necessary.
• DO NOT INSTALL DAMAGED PRODUCT! This luminaire has been properly packed so that no parts should have been damaged during
transit. Inspect to confirm. Any part damaged or broken during or after assembly should be replaced.
• Recycle: For information on how to recycle LED electronic products, please visit www.epa.gov.
• These instructions do not purport to cover all details or variations in equipment nor to provide every possible contingency to meet in
connection with installation, operation or maintenance. Should further information be desired or should particular problems arise which
are not covered sufficiently for the purchaser’s or owner’s purposes, this matter should be referred to Acuity Brands Lighting, Inc., a parent
company of Peerless Lighting.
WARNING
RISK OF ELECTRIC SHOCK
4Disconnect or turn off power before installation or
servicing.
4Verify that supply voltage is correct by comparing it with
the luminaire label information.
4Make all electrical and grounded connections in
accordance with the National Electrical Code (NEC) and
any applicable local code requirements.
4All wiring connections should be capped with UL approved
recognized wire connectors.
4To prevent luminaire row from over-­current: By adding
the input current of each luminaire section marked on
the luminaire, the total current per power feed must not
exceed the maximum line wire amperage marked on the
luminaire and the power feed cord/wire amperage rating
whichever the least.
WARNING
RISK OF BURN
4Allow lamp/luminaire to cool before handling. Do not
touch enclosure or light source.
4Do not exceed maximum wattage marked on luminaire
label.
4Follow all manufacturer’s warnings, recommendations and
restrictions for: driver type, burning position, mounting
locations/methods, replacement and recycling.
Part Number: PIN004102 Description: “INSTR, IMPORTANT SAFETY LED” Revision: C Effective Date: 07/2012 ECO3665 page 1 of 2
2246 5th Street, Berkeley, CA 94710 • Tel: 510.845.2760 • Fax: 510.845.2776 • Email: [email protected] • PeerlessLighting.com
© 2014 Acuity Brands Lighting, Inc. All Rights Reserved. “Peerless” is a registered trademark of Acuity Brands Lighting.
Products in this document may be covered by one or more U.S. Patents and Patents Pending. Specifications subject to change without notice.
Limited warranty applies. Complete warranty terms located at www.AcuityBrands.com/CustomerResources/Terms_and_Conditions.aspx
General Installation Instructions LED A
General Installation Instructions
LED
CAUTION
RISK OF INJURY
CAUTION
RISK OF FIRE
4Wear gloves and safety glasses at all times when removing
luminaire from carton, installing, servicing or performing
maintenance.
4Avoid direct eye exposure to the light source while it is on.
4Keep combustible and other materials that can burn away
from lamp/lens.
4Do not operate in close proximity to persons, combustible
materials or substances affected by heat or drying.
CAUTION
RISK OF PRODUCT DAMAGE
4Never connect components under load.
4Do not mount or support these luminaires in a manner that can cut the outer jacket or damage wire insulation.
4Unless individual product specifications deem otherwise: Never connect an LED product directly to a dimmer packs, occupancy
sensors, timing devices, or other related control devices. LED luminaires must be powered directly off a switched circuit.
4Unless individual product specifications deem otherwise: Do not restrict luminaire ventilation. Allow for some volume of airspace
around luminaire. Avoid covering LED luminaires with insulation, foam or other material that will prevent convection or conduction
cooling.
4Unless individual product specifications deem otherwise: Do not exceed luminaire’s maximum ambient temperature.
4Only use luminaire in its intended location.
4LED products are polarity sensitive. Ensure proper polarity before installation.
4Electrostatic Discharge (ESD): ESD can damage LED fixtures. Personal grounding equipment must be worn during all installation or
servicing of the unit.
4Do not touch individual electrical components as this can cause ESD, shorten lamp life or alter performance.
4Some components inside the luminaire may not be serviceable. In the unlikely event your unit may require service, stop using the
unit immediately and contact a Peerless Lighting representative for assistance.
4Always read the fixtures complete installation instructions prior to installation for any additional luminaire specific warnings.
SAVE THESE INSTALLATION INSTRUCTIONS
Please see product specific installation instructions for additional warnings or any applicable FCC or other regulatory statements.
Failure to follow any of these instructions could void product warranties.
For a complete listing of product Terms and Conditions, please visit PeerlessLighting.com.
Peerless Lighting, an Acuity Brands Company, assumes no responsibility for claims arising out of improper or careless installation or handling of its products.
Part Number: PIN004102 Description: “INSTR, IMPORTANT SAFETY LED” Revision: C Effective Date: 07/2012 ECO3665 page 2 of 2
2246 5th Street, Berkeley, CA 94710 • Tel: 510.845.2760 • Fax: 510.845.2776 • Email: [email protected] • PeerlessLighting.com
© 2014 Acuity Brands Lighting, Inc. All Rights Reserved. “Peerless” is a registered trademark of Acuity Brands Lighting.
Products in this document may be covered by one or more U.S. Patents and Patents Pending. Specifications subject to change without notice.
Limited warranty applies. Complete warranty terms located at www.AcuityBrands.com/CustomerResources/Terms_and_Conditions.aspx
General Installation Instructions LED
B
Peerless Mino 1x4 Recessed
INSTALLATION INSTRUCTIONS
PIN006300 Rev. B 08/20/14 ECO3715
MN9
These installation instructions are used for installing the following luminaires and kits:
Luminaire
Mounting Kit
MN9 1x4 G or ST
LATC / FLNGW
WARNING: Please read the “important safety instructions” prior to installation of this product.
A) Identification of MN9 1x4 Luminaire ………………………………………………………………………… Page 1
B) 1x4 Recessed Luminaire Installation ..……………………………………………………………………… Page 2
C) Drywall Grid Adapter Option (FLNGW) ………...…………………………………………………………... Page 3
D) Lens Care Instructions ...…………………………..…………………………………………………………. Page 3
A) Identification of MN9 1x4 Luminaire
Luminaire Components
1
PIN005702 Rev. B 08/20/14 ECO3715
MN9
B) 1x4 Recessed Luminaire Installation
1
Remove access plate. Run power
cord from junction box to luminaire,
knocking out one hole in access plate
to pass cord through. Perform wire
splices and insert wires back into the
luminaire.
PIN000000
Rev. X 00/00/00 ECO0000
2
3
XXX
Use ground screw on access plate to
ground luminaire. Replace access
plate.
Ensure that extended and hanging
brackets are in the correct position for
the type of grid used. Use alternate
holes in the extended and hanging
brackets if necessary.
4
5
6
Install luminaire into ceiling by resting
the four extended brackets onto the
ceiling grid.
Attach provided LATC clips on each
mounting bracket loosely. Adjust clips
vertically to engage with “T” member
and tighten screws. Complete support
to structure using cables attached to
LATC clips.
Peel away lens cover after luminaire is
fully installed.
2
PIN005702 Rev. B 08/20/14 ECO3715
MN9
C) Drywall Grid Adapter Option (FLNGW) for Sheet Rock Ceilings (5/8” Thick)
Minimum Ceiling Clearance = 10”
‘L’ bracket
(4X)
1
2
Drywall
screws
Holes for
guide
wires to
structure
3
PIN000000 Rev. X 00/00/00 ECO0000
Sheet rock
Guide wires
to structure
(4X) (by
others)
CONTRACTOR
TO SPAKLE,
FEATHER AND
SAND TRIM
#6 screws
(4X)
APPROX
½”
Drywall grid adapter kit comes
assembled with #6 screws (4X) and “L”
brackets (4X) as illustrated above.
4
XXX
Conduit
(by others)
Fasten sheet rock into aluminum
extrusion frame using drywall screws.
Drywall grid adapter is designed for 5/8”
sheetrock, so allow approximately 1/16”
for mudding and blending to finish ceiling.
Make sure that the frame is square and
tight against the ceiling. Ensure guide
wires (by others) to structure (by
others) are properly secured.
5
6
Ground screw
Remove access plate. Run power cord
from junction box to luminaire, knocking
out one hole in access plate to pass
cord through. Perform wire splices and
insert wires back into the luminaire.
7
Luminaire rests
SECURELY on
four sides
Ensure the luminaire rests securely on
drywall kit with brackets on all four sides
Use ground screw on access plate to
ground luminaire. Replace access
plate.
Insert luminaire into ceiling through the
drywall kit.
8
9
From above, completed installation
should look like this picture.
Peel away lens cover after luminaire is
fully installed.
D) Lens Care Instructions
Once installed, if the Peerless Mino lens needs to be removed for any reason, wear cotton gloves to protect against
fingerprints. Clean lenses with soft cloth. Dampen cloth with water if needed. When reaffixing the lens, push the lens up
from the center so that it is flat against the housing before retightening the thumbscrews.
3