Employers requirements - Tamil Nadu Government

Section VI. Employer’s Requirements
2-131
PART-2
Section –VI
Employer’s Requirements
2-132
Section VI. Employer’s Requirements
Scope of Supply of Plant and Installation Services by the
Contractor
Technical Specifications
Disaster Warning Announcement System
DWAS
Version 1.0
Technical & Functional Requirements and Technical
Specifications
Section VI. Employer’s Requirements
2-133
Table of Contents
1
1.1
2
2.1
3
4
4.1
5
5.1
5.2
5.3
5.4
6
6.1
6.2
7
7.1
7.2
7.3
7.4
7.5
7.6
7.7
7.8
7.9
7.10
8
9
10.
Introduction
Abbreviations
System Architecture
System Components – Description
DWAS – C
DWAS – D Unit
DWAS – R Unit.
Summary of Technical Specifications ……………………………………
DWAS – Detailed Technical Specifications
DWAS – System – General Requirements
DWAS - C Specifications
DWAS – C - General Requirements
DWAS – C - Functional Requirements
DWAS – C – Storage Requirements
DWAS – C –Security Requirements
DWAS – D Specification
………………………………………….
DWAS – D – General Requirements
DWAS – D – Functional Requirements
DWAS – R Specification
DWAS – R – General Requirements
DWAS – R – Functional Requirements
DWAS – R – Maintenance Requirements
DWAS – R – Powering Requirements
DWAS – R – Solar Panel Requirements
DWAS – R – Battery Requirements
DWAS – R – Communication Networks Port Requirements
DWAS – R – Audio Broadcast Port Requirements
DWAS – R – Hot line Port Requirements
DWAS – R – Light Port Requirements
Other Requirement Specification
List of activities by the Supplier & Purchaser
Warranty Specification
134
136
137
137
137
138
138
139
139
139
140
140
141
142
142
142
142
143
143
143
144
145
145
146
146
146
147
148
148
149
149
151
2-134
Section VI. Employer’s Requirements
Introduction
Background
Tamil Nadu has a long coastline of 1076 KM constituting 12% of the coastline of
India comprising of 13 coastal districts, 25 coastal blocks and 591 fishing villages. The
coastal area of Tamil Nadu is multi hazard prone in nature. The major natural hazards
that threaten the Tamil Nadu coast frequently are cyclones and associated storm
surges. Floods and flash floods, particularly in urban areas, are not uncommon. In the
past, it was only the cyclone and flood related disasters that occurred along the coastal
areas but in the recent years, we have witnessed the deadliest tsunami disaster all
along the Tamil Nadu coast, prone to vulnerable to earthquake and allied hazards. The
areas are vulnerable to disaster because of high concentration of people, buildings, and
infrastructure and socio economic activities. Therefore it is very important to prepare
the villages and community with a disaster mitigation plan in order to reduce the
damage and losses to lives and property.
The World Bank funded Emergency Tsunami Reconstruction Project (ETRP) with
a financial assistance of US$ 423 million focused on providing multi-hazard resistant
houses with basic amenities, restoration of livelihood and repair and reconstruction
works. Implementation of the project commenced in April 2005 and the project was
programmed to be implemented by Rural Development, Municipal Administration, Town
Panchayats, Public Works (WRO), Public Works (Building Organisation), Fisheries,
Agriculture, Horticulture, Animal Husbandry and Veterinary Sciences, Environment,
Forest departments besides Tamil Nadu Slum Clearance Board and Tamil Nadu Water
Supply and Drainage Boards.
The project now enters the second phase of rehabilitation and economic
recovery. In the second phase commencing from 13.08.2009, the scheme for
reconstruction of multi-hazard disaster resistant housing in 11 [Eleven] coastal districts
[except Chennai & Thiruvarur districts] for vulnerable population, construction of
evacuation routes and signages Evacuation shelters
[in 12 coastal districts
excluding Chennai] and installation of early warning systems in all the 13 coastal
districts including Chennai are proposed to be taken up under the restructured ETRP.
Vulnerability reduction of coastal communities (VRCC) – Phase II works:
The sub-components include-In situ reconstruction of vulnerable houses (about
17,000 units in 11 coastal districts), evacuation shelters (about 139 in number), escape
routes (about 150 km), installation of early warning systems and signages. The Rural
Development and Panchayat Raj department would be the implementing agency for
reconstruction of vulnerable houses evacuation routes and provision of signages in
evacuation routes. The Public Works department [Buildings Organisation] will construct
evacuation shelters and the Revenue Department [Project Management Unit] will
arrange to procure and install Early Warning Systems. These works are targeted to be
completed by December 2011.
Section VI. Employer’s Requirements
2-135
The scope of work of VRCC includes:
The proposal aims to build resilient coastal communities in the eleven tsunami
affected coastal districts namely 1. Thiruvallur, 2. Kancheepuram, 3. Villupuram, 4.
Cuddalore, 5. Nagapattinam, 6. Thanjavur, 7. Pudukottai, 8. Ramanathapuram,
9. Thoothukudi 10. Tirunelveli and 11. Kanniyakumari districts in Tamil Nadu and the
broad strategies suggested are:
a) Reconstruction of vulnerable houses in the coastal areas,
b) Construction of about 139 nos evacuation shelters, [ in 12 coastal districts
excluding Chennai]
c) Construction of Evacuation Routes for about 150 km including bridges/minor
crossings as found essential to provide easy escape routes in times of
emergencies, Signage’s to assist the people will also be incorporated.
d) Provision of Early Warning Systems with a focus on operationalization at
community level. [ in all the13 coastal districts including Chennai]
Scope of the Project
Though technology has advanced to predict an occurrence of a natural disaster like
Tsunami, earth quake, cyclone etc lack of timely alert results in huge loss of lives and
properties over years.
Many Rural and remote villages that are out of media coverage are the victims to these
disasters.
Other than natural disasters, there are man made disasters like chemical and biological
accidents as well as terrorist attacks that can cause similar damages.
With a view to overcome the above problems, it is proposed to provide Early Warning
System for the habitations in the 13 coastal districts of Tamil Nadu. The Technical
Specification and other parameters of the proposed Early Warning System are
furnished below:It is proposed to provide about 450 number of Early Warning System in the
habitations located along the coast of the tsunami affected coastal districts consisting
the following arrangements:
One central unit namely DWAS-C Unit is proposed to be installed in the office of the
Commissioner of Revenue Administration, Chepauk, Chennai – 5, Tamil Nadu, India
which shall have the overall control / dissemination / monitoring of all the EWS provided
in the habitations i.e., DWAS-R Units and the DWAS-D units provided in the 13 Coastal
districts and issue necessary communications / warnings etc as found necessary. Total
no of DWAS-C Unit is one [1] at Chennai
2-136
Section VI. Employer’s Requirements
One unit namely DWAS-D Unit is proposed one each in the following coastal districts
which shall control / monitor all the EWS i.e., DWAS-R Units provided in the
habitations within the district and act as link between the DWAS- C unit i.e., Central
Unit at Chennai and the rural areas i.e., DWAS-R Units within the district.
Sl No
1
2
3
4
5
6
7
District
Thiruvallur
Kancheepuram
Villupuram
Cuddalore
Nagapattinam
Tiruvarur
Thanjavur
Sl No
8
9
10
11
12
13
District
Pudukottai
Ramanathapuram
Thoothukudi
Tirunelveli
Kanniyakumari
Chennai
One unit namely DWAS-R Unit to be provided in each of the habitations or by
combining the habitations in such a way that the Audio range of the loud speakers
covers a distance of one(1) kilometer radius and the visual range of LED lights covers a
radius of one(1) kilometer during normal climate.
This document provides the Technical
Announcement System (DWAS).
specification of
a Disaster Warning
The Technical specifications are formed with an aim to cover the following requirements
•
•
•
•
•
•
•
Cost-effective and efficient system
Easily installable
Capable of up-grading to support 1,500 isolated points [i.e., DWAS-R Units ] to
the Central Headquarters and other districts [19 districts] over and above the 13
main coastal districts i.e., in total 32 i.e., DWAS-D Units
Wide geographical coverage supporting coastal and other hazard prone areas.
Rugged enough to work in harsh environmental conditions
Capable of working in remote areas with Solar Power to solve the problem of
erratic and intermittent grid power
System with Centralized monitoring provisions
The requirement of equipments for various units are as follows:-
1) Technical and Functional Requirement
1.1 Abbreviations
S.No
1
2
Acronym
DWAS
GSM
Description
Disaster Warning Announcement System
Global System for Mobile communication , a
digital cellular system standard for mobile based
voice communication
Section VI. Employer’s Requirements
3
GPRS
4
RAID
5
6
7
VRRP
IPSec
Layer
SSL
8
IP66
2-137
Global Packet Radio Service, a GSM initiative to
give high speed packet data service to GSM
mobile terminals
Redundant Array of Independent Disks, a storage
technology that supports redundancy.
Virtual Redundant Router Protocol
Internet Protocol Security Layer, a security
protocol with encryption running at IP layer.
Secured Socket Layer, a security protocol with
encryption running at session level for an
application.
Environmental Protection – Ingress Protection 66
corresponding to outdoor environment.
2.System Architecture
DWAS System consists of DWAS Central Unit (DWAS-C), DWAS District Units (DWASD), and DWAS Remote Units (DWAS-R) communicating through GSM/GPRS networks. The
mode of communication is Voice, Data, and SMS.
2.1
System Components - Description
DWAS – C Unit
DWAS-C is the Central Unit of the DWAS System. It shall have two server machines that
shall operate 24x7 at the Central Site. Each Server shall connect to two GSM/GPRS modems to
communicate to DWAS-D and DWAS-R Units. Each GSM/GPRS modem shall have
connectivity to telephone equipment. Each Server shall be connected to a high speed internet
modem / Router for data communication between DWAS-C, DWAS-D and DWAS-R units.
DWAS-C unit shall have a headphone with Microphone for recording and hearing of speech
message to be sent as disaster announcement to DWAS-R units.
The following table gives the hardware modules that are part of DWAS-C unit.
S.No
1
2
3
4
5
6
7
8
9
Item Description
Server Machine
Headphone cum Microphone
RAID Storage unit
GSM/GPRS modem
Internet modem / router
Telephone equipment
Ethernet switches
UPS system
SIM Card for GPRS connection
Nos.
2
2 sets
1
4
2
4
2
1
2
Table 1 – List of Hardware components for DWAS-C Unit
2-138
Section VI. Employer’s Requirements
DWAS – D Unit
DWAS – D Unit is the District level monitoring unit of the Disaster Warning System.
DWAS – D unit shall have a Computer loaded with Linux OS or Equivalent and has support for
internet connectivity to communicate with DWAS-C and DWAS -R units. DWAS-D unit shall
have two (2) GSM/GPRS with telephone equipment for voice and SMS communication with
local group of DWAS-R units.
The following table gives the hardware modules that are part of DWAS-D unit.
S.No
1
2
3
4
5
Item Description
Computer with Linux OS or
Equivalent
GSM/GPRS modem
Internet modem / router
Telephone equipment
SIM Card for GPRS connection
Nos.
1
2
1
2
2
Table 2 – List of Hardware components for DWAS-D Unit
DWAS – R Unit
DWAS – R Unit is the remote unit of the DWAS system. DWAS-R unit may be a custom
made and/or a standard hardware unit that can be powered from a Solar Panel or Grid power or
a battery. This unit shall have interfaces for a Telephone equipment/handset to make or receive
calls from a set of pre-stored telephone numbers. This unit shall have Loudspeakers to make
warning announcements and LED lights for visual indication.
The following table gives the hardware modules that are part of DWAS-R unit.
S.No
1
2
3
4
5
6
Item Description
DWAS – R base unit meeting
technical requirements as
provided in section 7
Solar Panel
Battery unit
Loudspeakers
LED Lights
SIM Card for GPRS connection
Nos.
1
1
1
3
4
2
Table 3 – List of Hardware components for DWAS-R Unit
Section VI. Employer’s Requirements
2-139
3.Summary of Technical Specifications
Item
No.
1
Name of Good or
Related Service
DWAS – C Unit
2
DWAS – D Unit
3
DWAS – R Unit
Technical Specification and Standards
As per Technical specifications given in
Sections 4.1, 5.1, 5.2 and 5.3
As per Technical specifications given in
Sections 4.1, 6.1 and 6.2
As per Technical specifications given in
Sections 4.1, 7.1, 7.2, 7.3, 7.4, 7.5, 7.6, 7.7,
7.8, 7.9, 7.10
4.DWAS – Detailed Technical Specifications
4.1
DWAS – System – General Requirements
S.No.
4.1.1
Specification
4.1.2
DWAS System shall support and control up to 1,500 DWAS-R units to be installed
in remote villages [ the present proposal provides for about 450 DWAS-R Units]
and 32 DWAS-D units of which the present proposal is to provide 13 DWAS-D
Units in the coastal districts .
4.1.3
DWAS System shall support functioning in disaster condition without grid electric
power and without solar power for a minimum of 2 days.
4.1.4
DWAS System shall support redundancy to the Server, Network connectivity to
internet and Storage level at the DWAS – C unit.
4.1.5
DWAS – R units of DWAS System shall have a redundancy at network
connectivity level through two different mobile networks primary GSM/GPRS
network and the other secondary GSM/GPRS network.
4.1.6
DWAS System shall have an optional support of an interface for interfacing
futuristic data modems like a 3G modem for data connectivity between DWAS-R,
DWAS-D and DWAS – C unit.
4.1.7
DWAS System shall have a centralized monitoring to know the functional status of
DWAS-C, DWAS – D and DWAS – R units using secured web based browser
application or a proprietary software in a password protected secured mode.
4.1.8
DWAS System units namely, DWAS – C, DWAS – R and DWAS – D units shall
have a voice interface port to receive and make voice calls through GSM/GPRS
network.
DWAS System shall ensure 24x7 system functionality for disaster warning
announcement
2-140
Section VI. Employer’s Requirements
4.1.9
DWAS System units shall have a data interface port for data and SMS
communication through GSM/GPRS network. There should be facility to log all
SMS communications and also to report to DWAS-C / D about any unauthorized
GSM/CDMA number access to DWAS-R Units.
4.1.10
DWAS System shall have all network transactions optionally carried out through a
secured network communication channel using Secured Socket Layer or IPSec
protocol or an equivalent secured connection protocol.
4.1.11
DWAS System shall have standard and/or proprietary implemented hardware
complying to RoHS Standards.
4.1.12
DWAS System shall record the log messages giving different events that occur in
the system for a period of past 6 months.
4.1.13
DWAS system shall comply to the following Environmental specifications.
a) Operating temperature – 0 – 50 o C
b) Operating humidity - 95% RH at 35 o C Non-Condensing
5
5.1
DWAS - C Specifications
DWAS – C - General Requirements
S.No.
5.1.1
Network Connectivity and Redundancy Specification
DWAS – C Unit shall have two Servers working in 1+1 configuration with
one active at any time and the other being active – redundant.
5.1.2
DWAS – C Units shall support redundant network connectivity to internet
with a single high speed link per server with 1+1 server configuration.
5.1.3
DWAS – C Unit shall have a high speed link with a minimum full duplex bit
rate of 2 Mbps to the internet.
5.1.4
DWAS – C Unit shall have router functionality with built-in hot plug in
redundancy through support of VRRP V3 or an equivalent protocol.
5.1.5
DWAS – C Unit shall have a 2 distinct well known fixed IP address one for
each of the servers that is reachable from anywhere in the internet.
High Availability Specification
5.1.6
DWAS – C Unit shall support inherent redundancy at each level so that
optionally fault tolerance can be supported by placing the redundant copy of
the server physically in a different location.
5.1.7
DWAS – C Unit shall support uninterrupted operation in case of grid power
failure for a period of 2 days without fail.
Section VI. Employer’s Requirements
2-141
Voice Interface Specification
5.1.8
DWAS – C Unit shall support incoming and outgoing voice calls through
GSM/GPRS modem with phone support
5.1.9
DWAS – C Unit shall support a headset with microphone interface to the
server for recording new speech messages to be sent to DWAS – R units
through GSM./GPRS network.
5.2
S.No.
5.2.1
DWAS – C - Functional Requirements
Specification
DWAS - C Unit shall have a server based on Linux OS or an equivalent
operating system
5.2.2
DWAS - C Server shall support upto 1,500 DWAS-R units and 32 DWAS-D
units for simultaneous health packet acknowledgement functionality
5.2.3
DWAS – C Server shall send disaster warning commands to announce prestored warning tones and messages for a required number of times through
the acknowledgement packet itself to each one of the DWAS – R units.
5.2.4
DWAS – C Server shall support FTP Server functionality with support for
multiple simultaneous FTP sessions, so that a new disaster warning
message if any will be conveyed within 10 min. of time.
5.2.5
DWAS – C Server shall map the IP address of the DWAS – R units against
their mobile numbers dynamically on reception of DWAS – R health
packets.
5.2.6
DWAS – C Server shall have a provision for sending SMS to a group of / all
DWAS – R units through the GSM/GPRS network.
5.2.7
DWAS – C Server shall have a console viewer and a command window to
know the operational status of the different units in the DWAS system and
to control their functionality.
5.2.8
DWAS – C Server shall have provision for generating alarms with different
priority levels on occurrence of specified events to trigger alert actions like
calling a particular emergency number or support number or generating an
SMS etc.
2-142
Section VI. Employer’s Requirements
5.3
DWAS – C – Storage Requirements
S.No.
5.3.1
Specification
DWAS – C shall support redundancy in data storage based on RAID 5 /
RAID 1+0 / RAID 0+1 technology.
5.3.2
DWAS – C shall have provision for storing the Software images of DWAS D & DWAS – R and Configuration files of each of DWAS-D &DWAS – R
units.
5.3.3
DWAS – C shall hold health status record data from all the DWAS-D &
DWAS-R units for a period of 6 months.
5.3.4
DWAS – C shall have provision to store the log messages of DWAS system
for a period of 6 months.
5.4
DWAS – C –Security Requirements
S.No.
5.4.1
5.4.2
Specification
DWAS – C Server shall support Firewall and Network Address Translation
(NAT) support to protect the Server from external elements on the internet
against unwanted flooding of packets and dynamic DoS (Denial of Service)
attacks.
DWAS – C shall support detailed logging of network access so that alert
notification can be generated to the Alarm system.
6
6. 1
DWAS – D Specification
DWAS – D – General Requirements
S.No.
6.1.1
Specification
DWAS – D unit shall be a Linux OS or equivalent operating system loaded
computer.
6.1.2
DWAS – D unit shall support data network connectivity to internet to
communicate with DWAS – C unit
6.1.3
DWAS – D unit shall support two GSM/GPRS modem interface to send
SMS to DWAS – C and DWAS – R units.
6.1.4
DWAS – D unit shall have telephone equipment connected to the
GSM/GPRS modems to receive and make phone calls to DWAS-C and
DWAS-R numbers.
Section VI. Employer’s Requirements
6.2
2-143
DWAS – D – Functional Requirements
S.No.
6.2.1
Specification
DWAS – D shall send a periodic health packet through the data network to
DWAS-C unit. The Periodicity of the health packet transmission shall be as
low as 10 minutes.
6.2.2
DWAS – D shall except an acknowledgement packet from DWAS – C unit
to indicate about the reception of the health packet.
6.2.3
DWAS – D shall have a provision to view the status of a group of DWAS-R
units through DWAS-C unit. This status shall be sent along with the
Acknowledgement packet from the DWAS-C unit itself.
6.2.4
DWAS – D shall have provision to send a group SMS to a set of DWAS-R
units, if requested by DWAS-C unit or by DWAS –D supervisor.
7
7.1
DWAS – R Specification
DWAS – R – General Requirements
S.No.
7.1.1
Specification
DWAS – R shall support two (2) GSM/GPRS based mobile connectivity
interface to connect to the DWAS-C unit.
7.1.2
DWAS – R shall support a primary interface of network communication
to the DWAS-C unit and that shall be decided at the time of site survey for
installation.
7.1.3
DWAS – R shall support a secondary interface of network connectivity
to the DWAS –C unit and it shall be used in the case of failure / total
unavailability of the Primary network.
7.1.4
DWAS – R shall use packet data communication by either GSM/GPRS as a
primary mode of connectivity to DWAS-C unit.
7.1.5
DWAS – R shall use SMS by either GSM/GPRS as a secondary mode of
connectivity to DWAS-C
7.1.6
DWAS – R shall support loudspeakers for Audio broadcast of messages
during the time of disaster with an audio range of minimum of 1 km.
2-144
Section VI. Employer’s Requirements
7.1.7
DWAS – R shall support a telephone port for making voice calls to /
from the unit for a set of pre-stored hotline numbers.
7.1.8
DWAS – R shall support a LED based light indication during the time of
disaster with a visual range of 1 km during normal climate.
7.1.9
DWAS – R shall support unit powering options from a Solar Panel, Battery
and Grid based Power source.
7.1.10
DWAS – R shall support operation for a minimum of 2 days without grid
power as well as solar power and with only batteries.
7.1.11
DWAS – R shall have visual indications on the box for the functioning of the
box to be monitored by maintaining personnel.
7.1.12
DWAS – R shall be an indoor unit with the outdoor fixtures for
loudspeakers, microphone, solar panel and LED Light to be mounted on an
external pole with cables running to the above fixtures. (the base rate may
be considering cables upto 30 meters and for additional length of cables
rate to be considered on a pro-rata basis.)
7.1.13
DWAS – R shall support RoHS compliant hardware unit.
7.2
S.No.
7.2.1
DWAS – R – Functional Requirements
Specification
DWAS – R shall have two modes of operation namely Normal mode and
Disaster Warning mode
7.2.2
DWAS – R shall send a periodic health packet through the underlying
connected Radio network to DWAS-C unit. The Periodicity of the health
packet transmission shall be as low as 10 minutes
7.2.3
DWAS – R shall expect an acknowledgement packet from DWAS – C unit
to indicate about the reception of the health packet as well as any new
message is available for downloading.
7.2.4
DWAS – R shall support File Transfer Protocol functionality to download
any new Speech broadcast message from the DWAS-C server.
7.2.5
DWAS – R shall have a functional loudspeaker operation test executed with
a standard test siren tone everyday at a pre-decided time.
7.2.6
DWAS – R shall have several self-testing levels to understand the health of
the unit including the functioning of the loud speakers.
7.2.7
DWAS – R shall have a manual testing mode that can be invoked with a
password protected command to test the functioning of the unit thoroughly.
Section VI. Employer’s Requirements
7.3
2-145
DWAS – R – Maintenance Requirements
S.No.
7.3.1
7.3.2
7.4
SI.No
7.4.1
Specification
DWAS – R shall support self maintenance features supporting periodic
health message packets giving the status of the different components in the
unit.
DWAS – R shall require a minimum periodic manual maintenance of once
in 2 weeks for cleaning the solar panels and inspecting the loudspeakers,
LED lights and other external fixtures.
DWAS – R – Powering Requirements
Specification
DWAS – R shall support unit powering options from a Solar Panel, Battery
and Grid based Power source. Grid based power source implies a powered
from a 230V AC supply.
7.4.2
DWAS – R shall have the capability to function for 2 days in the Disaster
Warning mode in the absence of Solar power and Grid power.
7.4.3
DWAS – R shall use maintenance free VRLA GEL batteries for its
operation.
7.4.4
DWAS – R shall normally operate from the solar panel and in case Solar
power is not sufficient, operate from grid power. In the absence of grid
power, DWAS – R shall operate from Battery supply.
7.4.5
DWAS – R shall have the required power supply protection devices in place
to avoid the damage caused to the DWAS-R unit due to erratic inputs, if
any.
7.4.6
DWAS – R shall be designed with a power supply and charge controller to
operate all the power generation circuits at their best efficiency and
minimum loss.
7.4.7
DWAS – R shall support typically a battery of capacity 42Ah – 64Ah to
operate complying to all its functional requirements.
2-146
Section VI. Employer’s Requirements
7.5
S.No
7.5.1
DWAS – R – Solar Panel Requirements
Specification
DWAS – R shall support mono crystalline or multi crystalline solar panel
7.5.2
DWAS – R shall support a Solar power generation based on an average of
4 hours of Sun time in a day.
7.5.3
DWAS – R shall support monitoring of Solar panel output voltage level so
that the charge controller can switch to other power resources.
7.5.4
DWAS – R shall be designed typically for a Solar panel with a Power output
of 50W to 64W at 12V or 24V or 48V.
7.6
S.No
7.6.1
DWAS – R – Battery Requirements
Specification
DWAS – R shall operate from a maintenance free VRLA – GEL battery
typically of the order of 42Ah.
7.6.2
DWAS – R shall ensure, that the Depth of Discharge of the battery lies in
the range of 60 – 50%, to get a long battery life.
7.6.3
DWAS – R shall have provisions of monitoring the battery charge level and
the input supply for charging periodically and send the status as part of
health packet to DWAS-C
7.6.4
DWAS – R shall have local LED indications at the DWAS – R unit to show
whether the unit is operated from battery and about the battery charge level
also.
7.7
S.No
7.7.1
7.7.2
DWAS – R – Communication Networks Port Requirements
Specification
DWAS – R shall support GSM/GPRS interface with an indoor antenna unit
complying to standards of ITU-T GSM/GPRS
DWAS – R shall support GSM/GPRS dual band / tri band / quad band class
B modem with multi-slot class 10 service supporting bit rates of a minimum
of 9.05 kbps to 85.6 kbps ( downstream)
•
•
•
•
•
Coding scheme
CS-1:
CS-2 :
CS-3:
CS-4:
1 Slot
9.05
13.4
15.6
21.4
2 Slot
18.1
26.8
31.2
42.8
4 Slot
36.2
53.6
62.4
85.6
Section VI. Employer’s Requirements
7.8
2-147
DWAS – R – Audio Broadcast Port Requirements
S.No
7.8.1
Specification
DWAS – R shall support up to 3 loudspeakers to enable audio
announcement during the time of periodic audio broadcast testing and
during disaster time.
7.8.2
DWAS – R shall support a configurable option to individually power the 3
loudspeakers.
7.8.3
DWAS – R shall support audio interface with an audio range up to roughly
1 km radius distance with a minimum sound level of at least 9 dB above the
ambient sound with a good sound intelligibility level.
7.8.4
DWAS – R shall support a maximum of up to 100 local pre-loaded tones /
speech message of 30 seconds each stored in the flash memory of the
DWAS-R unit
7.8.5
DWAS – R shall have a feature to support downloading of new tone /
speech message from DWAS-C unit end.
7.8.6
DWAS – R shall support a feature to test the physical working of Audio
Interface section by broadcasting a test tone once in a day at a pre-fixed
time.
7.8.7
DWAS – R shall support audio broadcasting of a tone /message for a
maximum duration of 1 minute time continuously.
7.8.8
DWAS – R shall support audio broadcasting of messages of 1 minute
duration to a maximum of 8 times a day, if the unit is operated from Battery
in the absence of solar and grid power.
7.8.9
DWAS – R shall support the capability to capture the broadcasted audio to
verify the functionality of the loudspeaker unit and give the update to
DWAS-C unit.
7.8.10
DWAS – R shall support power shutoff to loudspeaker when it is not in use.
7.8.11
DWAS – R shall support loudspeaker units capable of withstanding outdoor
environment complying to IP66 level with marine grade material also as the
installations of DWAS-R units are mostly near the coastal region.
7.8.12
DWAS – R shall support loudspeaker installation on poles at a height of
about 10 meters so that the hazardous decibel level threshold for human
hearing (130 dB SPL) is not exceeded at a normal human height of 5-6 feet.
The same shall be able to with stand against a wind speed of about
120 km/hour
2-148
Section VI. Employer’s Requirements
7.8.13
DWAS – R shall incorporate line protection against the lightning and other
accidental high voltage coupling that might happen in the exposed cabling
between the power amplifier and the externally installed loudspeakers.
7.8.14
DWAS – R shall have a provision to monitor the temperature at the power
amplifier section and to control the signal compression based on the
temperature.
7.8.15
DWAS – R shall have a provision to control the power level at the individual
Loudspeaker.
7.9
DWAS – R – Hot line Port Requirements
S.No
7.9.1
Specification
DWAS – R shall support an interface to connect either a standard
telephone equipment or a handset for receiving and making calls through
the hotline interface port.
7.9.2
DWAS – R shall support buzzer (85 – 90 dB SPL level) based ringing to
indicate an incoming call.
7.9.3
DWAS – R shall support a feature to allow incoming calls from a set of
allowed numbers to the hot line port.
7.9.4
DWAS – R shall support a pre-configured key code sequence protected
hotline mode to call pre-programmed list of numbers.
7.9.5
DWAS – R shall support a pre-programmed limit on call duration in the case
of Battery-only mode.
7.9.6
DWAS – R shall support a pre-programmed number of allowable incoming /
outgoing calls in the case of Battery-only mode.
7.10
S.No
7.10.1
DWAS – R – Light Port Requirements
Specification
DWAS – R shall provide the required light indication at the time of disaster
using White colour Light Emitting Diodes.
7.10.2
DWAS – R shall provide the light indication to all four directions with a
control to ON/OFF light in each direction
7.10.3
DWAS – R shall provide the lighting indication with a minimum visibility
range of 1 km during normal climate.
Section VI. Employer’s Requirements
2-149
7.10.4
DWAS – R shall provide the lighting indication at a typical height of about
10 meters.
7.10.5
DWAS – R shall switch ON and OFF the lighting indication during disaster
time.
7.10.6
DWAS – R shall have a limited ON/OFF intervals up to a pre-programmed
number of times per day, in case when the unit is operated from battery in
the absence of grid power and solar power.
7.10.7
DWAS – R shall have the LED based Light capable of withstanding external
environment complying to IP66 specification.
8. Other Requirement Specification
S.No
Specification
8.1.1
DWAS system requires service registration with a GSM/GPRS Service Provider to
get GSM /GPRS connectivity
8.1.2
DWAS system functioning requires a site survey of the villages where DWAS-R
units will be installed to decide on the number of loudspeakers required at the site
and the GSM/GPRS availability in the chosen place of installation.
8.1.3
DWAS-C unit requires two high speed internet links from a Internet Service
Provider
9. List of activities by the Supplier & Purchaser
[A]
Activities by the Purchaser
Space required for the installation of the EWS at various locations will
be arranged to be provided to the Contractor. Any change in location
will also be furnished to the Contractor before installation. The
Employer will furnish the details of sites for the installation of Plant &
Equipment before the scheduled installation date to allow the contractor
to perform the site inspection to verify the appropriateness of sites
before installation of the Plant & Equipment.
Where building is available for the installation of Early Warning
Systems, the Equipments can installed as below:1. The various equipments shall be provided in the space provided in
the building.
2. The Audio broadcasting system, LED light system to be installed in
First floor or Second floor over Marine grade GI pipe with clamps etc
as indicated in Annexure-B.
3. The Solar panel shall be installed over the terrace
4. Where no space is available in the building, the EWS system shall
be provided as per the Drawing No 1PMU/EWS over RCC pillar.
2-150
Section VI. Employer’s Requirements
[B]
Any change in the number of EWS [addition or deletion] to be provided
to the Supplier before installation.
Activities by the Supplier
Contractor to arrange for the safe custody of the equipments before /
after installation, commissioning, testing etc till the same are handed
over to the Employer.
The Contractor is responsible for all unpacking, assemblies, writing,
installations, cabling between Plant & Equipment units and connecting
to power supplies. The Contractor will test all Plant & Equipment
operations and accomplish all adjustments necessary for successful
and continuous operation of the Plant & Equipment at all installation
sites.
The Contractor is obliged to work closely with the Purchaser’s staff, act
within its own authority and abide by directives issued by the Employer
and implementation activities.
The Contractor will abide by the job safety measures prevalent in India
and will free the Employer from all demands or responsibilities arising
from accidents or loss of life the cause of which is the Contractor’s
negligence. The Contractor will pay all indemnities arising from such
incidents and will not hold the Employer responsible or obligated.
The Contractor is responsible for managing the activities of its
personnel or sub-contracted personnel and will hold itself responsible
for any misdemeanors.
The Contractor will treat as confidential all data and information about
the Employer, obtained in the execution of his responsibilities, in strict
confidence and will not reveal such information to any other party
without the prior written approval of the Employer.
The Contractor is responsible for and obliged to conduct all contracted
activities in accordance with the contract using state-of-the-art methods
and economic principles and exercising all means available to achieve
the performance specified in the Contract.
(C)
Training:
The contractor shall arrange to impart training to the Employer’s staff as
well the staff in the district collector’s office in the field of checking,
maintaining etc., of the Plant & Equipment. The training shall have to be
Section VI. Employer’s Requirements
2-151
provided for about -------------------- persons in two batches, one at Chennai
and another at Ramanathapuram.
10. Warranty Specification
All the equipments provided and installed by the Supplier should be warranted for
Three [3] years from the date of taking over of the systems by the Purchaser +
Three [3] years Annual Maintenance of the Plant & Equipment
•
•
•
•
Warranty will cover
Manufacturing defect
Design defect
Material defect
Failure for other reasons
etc
Annual Maintenance Contract shall cover the following;
In partial modification of the provisions, the warranty period shall be 36 months
from date of taking over of the Plant & Equipments. The Contractor shall, in
addition, comply with the performance guarantees specified under the Contract.
If, for reasons attributable to the Contractor, these guarantees are not attained in
whole or in part, the Contractor shall, make such changes, modifications, and/or
additions to the Plant & Equipment or any part thereof as may be necessary in
order to attain the contractual guarantees specified in the contract at its own cost
and expense and to carry out further performance tests in accordance with GCC
26.2.
•
If during operation, the real Hardware Down Time of any piece of equipment or
component thereof does not prove to be within 70% (seventy percent) of the
specified MTBF, the Contractor shall replace the unit of component with another
of at least the same performance and quality at no cost to the Employer.
•
Free maintenance services shall be provided by the supplier during the period of
Warranty / Defects Liability period of 36 months. After warranty/Defects Liability
period, annual maintenance and repairs of the entire system including supply of
spares etc. for next 36 months will be carried over by the supplier. During
Warranty/Defects Liability Period & maintenance period any third party software
installation would be the responsibility of the bidder.
•
The maximum response time for a maintenance compliant from any of the
destination specified in the schedule of requirements (i.e., time required for
suppliers maintenance engineers to report to the installations after a request
call/telegram/fax is made or letter is writer) shall not exceed 24 hours.
•
The Contractor will accomplish preventive and breakdown maintenance activities
to ensure that all hardware execute without defect or interruption for at least 98%
uptime for 24 hours a day, 7 days a week of operation of the machine worked
on a quarterly basis. If any critical component of the entire configuration is out of
2-152
Section VI. Employer’s Requirements
service for more than three days, the Contractor shall either immediately replace
the defective unit or replace it at its own cost. The Contractor will respond to a
site visit and commence repair work on the equipment within 72 hours of being
notified of equipment malfunction.
•
It is expected that the average downtime of an item will be less than half the
maximum downtime (i.e., defined as number of days for which an item of
equipment is not usable because of inability of the Contractor to repair it) as
mentioned in the form of technical details. In case any item is not usable beyond
the stipulated maximum downtime the supplier will be required to arrange for an
immediate replacement of the same, till it is repaired. Failure to arrange for the
immediate repair/replacement will be liable for penalty of Rs.500/- per day per
item. The amount of penalty will be recovered from bank guarantee during
warranty/Defects Liability period or annual maintenance period as the case may
be.
Total Requirements of the Early Warning System
Sl
No
1
2
3
4
5
6
7
8
9
10
11
12
13
Name of District
Chennai
Thiruvallur
Kancheepuram
Villupuram
Cuddalore
Nagapattinam
Tiruvarur
Thanjavur
Pudukottai
Ramanathapuram
Thoothukudi
Tirunelveli
Kanniyakumari
Total
DWAS-C Unit
1
1 No
Nos required
DWAS-D Unit
1
1
1
1
1
1
1
1
1
1
1
1
1
13 Nos
DWAS-R Unit*
15**
33
45
15
86
54
6
19
30
64
19
20
33
439
Note:- * The numbers of DWAS-R Units are likely to vary by about 10% either way.
** The details of location will be furnished later.
Section VI. Employer’s Requirements
1
2-153
Technical Specifications
ProLiant BL480c Server Blade
Processor
Quad-Core Intel® Xeon® processor X5355 (2.66 GHz, 1333 MHz FSB)
Quad-Core Intel Xeon processor E5345 (2.33 GHz, 1333 MHz FSB)
Quad-Core Intel Xeon processor E5335 (2.0 GHz, 1333 MHz FSB)*
Quad-Core Intel Xeon Processor E5320 (1.86 GHz, 1066 MHz FSB)
Quad-Core Intel Xeon Processor E5310 (1.60 GHz, 1066 MHz FSB)
Dual-Core Intel Xeon Processor 5160 (3.00 GHz, 1333 MHz FSB)
Dual-core Core Intel Xeon Processor 5150 (2.66 GHz, 1333 MHz FSB)
Dual-core Core Intel Xeon Processor 5140 (2.33 GHz, 1333 MHz FSB)
Dual-core Core Intel Xeon Processor 5148 (2.33 LV GHz, 1333 MHz FSB) Low Voltage (LV)*
Dual-core Core Intel Xeon Processor 5130 (2.00 GHz, 1333 MHz FSB)*
Dual-core Core Intel Xeon Processor 5120 (1.86 GHz, 1066 MHz FSB)*
Dual-core Core Intel Xeon Processor 5110 (1.60 GHz, 1066 MHz FSB)
Dual-core Core Intel Xeon Processor 5080 (3.73 GHz, 1066 MHz FSB)*
Dual-core Core Intel Xeon Processor 5063 (3.2 GHz 1066 MHz FSB) Mid-Voltage (MV)*
Dual-core Core Intel Xeon Processor 5060 (3.2 GHz, 1066 MHz FSB)
Dual-core Core Intel Xeon Processor 5050 (3.0 GHz, 667 MHz FSB)*
Upgradeability
Upgradeable to dual processors
Cache Memory
2x2MB Level 2 cache memory (5000 Series )
1x4MB Level 2 cache memory (5100 Series )
2x4MB Level 2 cache memory (5300 Series)
Chipset
Intel® 5000P Chipset
Memory
Type
Standard
Maximum
PC2-5300 Fully Buffered DIMMs running at 667 MHz
2 GB (2 x 1 GB)
4 GB (4 x 1 GB)
48 GB (12 x 4 GB)
2-154
Section VI. Employer’s Requirements
Network Controller
Four (4) embedded NIC ports, plus (1) additional management NIC port:
One (1) embedded NC326i Dual Port Gigabit Server Adapter
Two (2) embedded NC373i Multifunction Gigabit Server Adapters
One (1) additional embedded 10/100 NIC dedicated to iLO 2 management
Expansion Slots
Three Mezzanine slots (Two x8 and one x4)
Storage Controller
HP Smart Array P400i Controller
256MB memory module supports RAID 0/1/1+0/5
Maximum Internal Storage
Hot Plug Serial Attach SCSI (SAS)
Hot Plug Serial ATA (SATA)
584GB SAS
240GB SATA
4 x 146GB Serial SCSI
4 x 60GB Serial ATA
Graphics
Integrated ATI RN-50 1280 x 1024 x 16M color (32 MB DDR1 memory)
Graphics Resolution Supported
Resolution Color Depths
Depths 1280 x 1024, 16.7M , 64k, 256,16
1024 x 768, 16.7M, 64k, 256, 16
800 x 600, 16.7M, 64k, 256, 16
640 x 480, 16.7M, 64k, 256, 16
Section VI. Employer’s Requirements
2
Head Phone & Microphone Specification
A. Head Phone Specification
• Frequency : 20 ~ 20000 Hz
• Speakers : 40 mm ferrite w/myler cone.
• Impedance : 32 ohms + (DC impedance)
• Sensitivity : 105dB +/- 3dB at 1KHz w/Mw(spk)
• Max. Input power : 28 mW
• Polar pattern : Omni-directional
• Sensitivity : -40 dB 3 dB
• Weight : 300 gm (with cord)
• Plug : 3.5mm stereo plug x 2
Wireless USB receiver
Reliable 2.4 GHz connection with 33 ft. range
Wired USB cord
Plug-and-play digital audio with USB cord
Rotating boom microphone
Reduces background noise for clearer conversations
Adjustable Headband
Personalize your fit
Style
Choose the design that’s most comfortable for you
System Support
Linux OS or equivalent
Audio Application Support
Skype, Windows Live Messenger, Yahoo Messenger, Windows Media Player, iTunes,
B. Microphone
• Frequency response 20~16000Hz
• Impedance 2.0 Kohms
• Max power inputs : 0.4mA
• Sensitivity -58dB dB=1V/PA at 1KHz
• Plug 3.5 mm
2-155
2-156
3
Section VI. Employer’s Requirements
GPRS / GSM Modem Specifications
Antenna Interface
Inbuilt Antenna
Frequency bands
EGSM 900, DCS 1800, and PCS 1900, GSM 850 Capability
GSM / GPRS
Provides for all GSM/GPRS authentication, encryption, and frequency hopping
features supported
algorithms. GPRS Coding Schemes CS1-CS4 supported. Multi-Slot Class 10
(4RX/2TX, Max 5 Slots).
GSM/GPRS
Mobile -originated and mobile-terminated SMS messages: up to 140 bytes or up to
Functionality
160 GSM 7-bit ASCII characters.
Reception of Cell Broadcast Message
SMS Receipt acknowledgement
Circuit Switched Data (Transparent & Non-transparent up to 9.6 kbps)
Voice (EFR, FR, HR)
Supports Unstructured Supplementary Service Data (USSD)
Multi -Slot Class 10 Supported (4RX/2TX), (5 Slot Max)
PBCCH/PCCCH supported.
SIM
3 V Mini-Subscriber Identity Module (SIM) compatible
Operating & Storage
00C to +600C (Operating)
temperature
-100C to + 850C (Storage)
Relative humidity
5-95%
Air pressure
70 kpa to 106 kpa (-400 m to 3000 m)
(altitude)
Transmit Power
Frequency
Power Class
Transmit Power
1900 MHz
GSM Power Class 1
1-W conducted power maximum (30 dBm +/-2
dB), measured at the antenna port
1800 MHz
850 MHz
GSM Power Class 4
dB), measured at the antenna port
900 MHz
Receive Power
2-W conducted power maximum (33 dBm +/-2
Frequency
Sensitivity
Mode
1900 MHz
-106 dBm (typical)
GPRS Coding Scheme 1 (CS1)
-106 dBm (typical)
GPRS Coding Scheme 1 (CS1)
1800 MHz
850 MHz
900 MHz
VOICE PORT
RJ11 / suitable connector required for connecting Telephone equipment / Head set
DATA PORT
RS232
Section VI. Employer’s Requirements
2-157
4
UPS
Salient Features
Flexible and adaptable
IGBT Rectifier
High Efficiency up to 94% for On-Line mode and up to 98% for Eco Mode
Compact footprint
Intuitive Monitoring
High availability architectures
Online / Frequency Converter / Eco and Intelligent Eco modes of operations
Technical Specifications
Voltage
Voltage Range
Frequency
Frequency range
Input Power Factor
THDi
Bypass Frequency Tolerance
Voltage
Static Regulation
Frequency
THDu
< 3% for 100% Non-Linear Load
Crest Factor
Overload (at 0.9 load pf)
150% for 60 seconds
168% for 5 sees
Eco Mode
On-line Mode
Ambient Temperature
Retaive Humidity
Altitude
Colour
Noise Level
Safety Emission
EMC
Enclosure Protection
Marking
Communication Options
320 - 480V at 100% load
240 - 480V at 50% load
50/60 Hz (Selectable)
+ 10%
> 0.99
<3%
+2%
3 x 380/400/415 V +N (Settable)
+ 1%
50 / 60 Hz
< 1% for 100% Linear Load
3:1
125% for 10 minutes
> 98.0%
upto 94.0%
0 to 40 deg C
95% Max non-condensing
1000m w/o de-rating
RAL 7016
48 - 52 (dBA at 1 meter)
EN 62040-1-1
EN 62040-2
IP 20 (others on request)
CE
RS 232 ports for remote contacts
2-158
Section VI. Employer’s Requirements
Audio Broadcast System, LED Light & Solar
Power Requirements
5
A. Power Amplifier
Frequency response 300 HZ-3.4K HZ
Output coupling – Direct coupling.
Output power per Loud Speaker typically - 100 Watt
Efficiency 85-90 %
Maximum continuous ON time of PA – 1 minute
B. Loud Speaker
o No of speaker – 3 nos (1 to cover 120 degree)
o Horn type – Flare / Trumpet
o Max sound output - 113 dB SPL@1walt@1metre
o Rated power - 100 W RMS
o Peak Power - 150 W
o Impedance –upto 16 Ohms
o Configuration - Parallel connection of loud speaker
o Power to speaker independently controlled
o Pole height to be 8-10 m from ground level
Mounting on Marine Grade G.I pipe heavy-duty 90 mm dia fixed on concrete pedestal
and clamped with wall as painted with corrosion proof phosphate powder coating Pothwith IP class 66 enclosure.
C. Speech & Tone Message Requirements
•
Support for upto 45 standard locally stored tones and upto 30 customized
speech or tones with an over all capacity to store upto 100 tones / speech
samples of 20 seconds each.
•
Maximum continuous broadcasting duration of tone / speech – Not to
exceed 1 minute
•
Audio broadcasting 8 times a day in battery mode operation and more than
8 times under grid power support.
•
Testing tone played once per day at fixed time.
•
Automatic response to DWAS-C by sensing the broadcasted message
being played
Section VI. Employer’s Requirements
2-159
D. Telephone / Head set Requirements
•
Standard Telephone equipment interface / Head set with Buzzer based
ringing
•
Incoming call allowed only from DWAS-C or DWAS-D with and some pre–
programmed numbers only.
•
Hot line key press for calling DWAS-C or DWAS-D units.
E. Light Port Requirements
Light indications with white color LED based light
Light to cover all four direction with a control of ON / OFF
Light with minimum luminescence to provide visual range of 1 KM during
normal climate
LED based light capable of with standing external environment complying
to IP 66 Specification
Pole mountable along with loud speakers
F. Solar Panel Requirements
Maximum Power - 50w to 60w at 12v or 24v or 48V
Cell type - Mono/Multi crystalline
To be fixed over the roof slab
G. Battery Requirements
Maintenance free VRLA GEL type
Capacity- minimum – 42 AH
Depth of discharge - 30%
Solar Chargeable
Output voltage -12V + / 0.5 V
2-160
Section VI. Employer’s Requirements
6
ETHERNET SWITCH
Specifications
Ethernet Interface
10/100/1000BASE-T Ports
Minimum of 24 ports for Connecting Servers and
Internet Routers
RS-232 Console Port
1 for Management and configuration of the Switch
Power
Power Supply
100 to 120VAC, 200 to 240VAC, 50/60Hz,
Internal Power Supply
Section VI. Employer’s Requirements
2-161
7 IP rating specification
The IP (Ingress Protection) System provides a means of classifying the degrees of
protection to dust and water afforded by electrical equipment and enclosures. The system is
recognized in most European countries and is set out in European Standard BS EN 60529:1991.
specification for degree of protection provided by enclosures (IP code).
The system has two figures although it can have a third for mechanical impact, but this is
not normally used in practice. The first figure shows the degree of protection against solid
objects and the second figure shows the degree of protection against liquids.
If a unit has an IP rating of IP43 you can see from the table that it would be protected
against solid objects greater than 1mm and against water sprayed to an angle of 65 degrees from
the vertical.
First Number
Protection against solid objects
0
No protection
1
Protection against solid objects over 50mm
2
Protected against solid objects over 12mm l
3
Protected against solid objects over 2.5mm
4
Protected against solid objects over 1mm
5
Protected against dust- limited ingress (no harmful deposit)
6
Totally protected against dust
Second Number
Protection against liquids
0
No protection
1
Protection against vertically falling drops of water
2
Protected against direct spray of water up to 15 degrees from the vertical
3
Protected against sprays of water up to 65 degrees from vertical
4
Protected against water sprayed from all directions.
5
Protected against low pressure jets of water from all directions.
6
Protected against strong jets of water eg. for use on ship decks.
7
Protected against the effects of immersion up to 1 meter for short periods
8
Protected against long periods of immersion under pressure
2-162
Section VI. Employer’s Requirements
DWAS-R Unit[civil, installation &other related works]
1. Where no space is available in the existing buildings or where there is no building is
available to accommodate the DWAS-R Unit, the same shall be provided over the
proposed RCC structure as per drawing No-1.
2.
One RCC pillar of 60cm diameter shall be raised for 4.0 meter above the existing
ground level and a base slab provided to the required size & thickness as per the
drawing for accommodating the various components of DWAS-R Unit and another
slab provided [Roof slab] over which the solar panel shall be installed
as per
drawing.
3. Side walls shall be provided with brick work on all sides with steel shutters provided
with locking arrangements on the front side using marine grade steel angles and
sheet of sizes as per drawing and painted with anti corrosive paint.
4. The solar panel shall be provided over the roof slab .
5. RCC Column of 40cm dia shall be raised over the roof slab to a height of 10.75 m
above the existing ground level . Suitable clamps for fixing 3 nos of loudspeakers at
10.00 m height and clamps for fixing the LED lights 4 nos at 9.50 meter above
ground level. On top of the pillar necessary provision with bolts to be provided for
fixing roof covering. The clamps for fixing the Loud speakers and LED lights shall be
connected to a steel rope with suitable Pulley for raising and lowering the unit for
carrying out any repair or replacement etc.
6. All masonry works shall be painted with 2 coats of cement paint over one coat of
cement primer.
7. The steel doors shall be pained with two coats of anticorrosive paint over one coat of
red oxide primer.
8. On top of the RCC column necessary cover with marine grade steel sheet of 12
gauge thickness of size 1.00mX1.00m as per drawing to provide protection to the
loud speakers and LED light fittings. The sheet shall be painted with anticorrosive
paint two coats over a priming coat of red oxide.
9. Where there are space available in the existing buildings to accommodate the DWAS-R Unit
components , the bidder has to offer their rate for fixing the Loudspeakers at 10.50 meters
above ground level using marine grade GI pipe of 90 MM diameter heavy type over the
Section VI. Employer’s Requirements
2-163
existing roof slab with suitable Cement Concrete pedestals of 45cmX45X75cm height
around the pipe and providing stay wires of 12 gauge on all four directions .Four [4]
numbers of LED lights shall be fixed with suitable clamps at 9.50 meter level and three [3]
numbers of loud speakers shall be fixed with suitable clamps at 10.00m level. Suitable
pulley arrangement for lowering or raising the Loud speakers and LED lights for repair or
replacement on top of the pipe and a cover with marine grade steel sheet of 12 gauge
thickness of size as per drawing to provide protection to the loud speakers and LED light
fittings. The sheet shall be painted with anticorrosive paint two coats over a priming coat of
red oxide.
drawing No-2
2-164
Section VI. Employer’s Requirements
Attachment-1
Statement showing the details of coastal Habitations and locations proposed for
the installation of Early Warning Systems [DWAS-R units]
List of Location of Early Warning System
District: Thiruvallur
S.No
Taluk
Village
Habitation
Place of Installation
(1)
(2)
(3)
(4)
(5)
Pulicat
Pulicat
V.A.O.s Office, Pulicat
2
Pulicat
Lighthousekpuppam
Panchyat Union School,
Lighthousekppam
3
Thangalperumbulam
Sathankuppam
(Thangalperumbulam. Pt)
Panchyat Union School, Building
4
Kattupalli
Kattupalli (P)
Cyclone shelter
5
Pulicat
Kottaikuppam (P)
Panchayat Office, Kottaikuppam
6
Aurivakkam
Aurivivakkam (E)
Women Self Help Group Building
Kallur
Kallur (P)
Perumal Koil, Pudhukuppam
7
8
9
Ponneri
1
Kallur
Annamalaichery
Periyamangodu (Kallur
Panchayat)
Annamalaicheri
(Sirulapakkam Panchayat)
Amman Koil, Periyamangodu.
Angalamman Koil, Annamalaicheri
Pulicat
Jameelabath
(Kottaikuppam Panchayat)
Mosque Building, Jameelabath
11
Pulicat
Pasiyavaram (instead of
Edamani)
Perumal Koil, Pasiyavaram
12
Pulicat
Vairavankuppam
Amman Koil, Vairavankuppam
13
Pulicat
Gunankuppam
Television Room, Gunankuppam
14
Pulicat
Arangankuppam (instead
of Kulathumedu)
Television Room, Arangankuppam
15
Tiruvottyur
16
17
18
Ambathur
10
Sudhanthirapuram
Palwadi
Tiruvottyur
Ondikuppam
Cyclone shelter
Tiruvottyur
Tiruvottiyurkuppam
Municipal Primay School
Tiruvottyur
Kasi Kovilkuppam
Palwadi
Section VI. Employer’s Requirements
2-165
Tiruvottyur
Pudhu Nagar (Annai
Sivagami Nagar 11th St.)
20
Ennore
Bharathiyar Nagar
Palwadi
21
Ennore
Appar Nagar
Palwadi
22
Ennore
Eranavoorkuppam
Palwadi
23
Kathivakkam
24
Kathivakkam
25
Arambakkam
27
28
29
30
31
32
33
Tiruvallulr
26
Gummidipoondi
19
Tazhakuppam
(Kathivakkam)
Ennorekuppam
(Kathivakkam)
Nochikuppam
(Arambakkam)
Palwadi
Arambakkam
Battaikuppam
(Armbakkam)
Panchayat Office, Arambakkam
Sunnambukulam
Karaikadu
Panchayat Union Middle School,
Karaikadukuppam
Sunnambukulam
Sunnambukulam
Panchayat Office, Sunnambukulam
Obasamuthiram
Vallambedu
Co-operative Fair Price Ship,
Vallambedukuppam
Obasamuthiram
Obasamudram
Panchayat, Office Obasamudram
Karungaali
Korai Kuppam
Temple Land
Karungaali
Karungaali
Temple Land
Kaalanji
Kaalanji
Temple Land
Municipal Primay School
Panchayat, Union Middle School,
Nochikuppam
2-166
Section VI. Employer’s Requirements
District: Kancheepuram
S.No
Taluk
Village
Habitation
Place of Installation
(1)
(2)
(3)
(4)
(5)
Kanathur Reddy kuppam
Kanathur Reddy
kuppam
Early Warning System located in
Panchayat Union, Primay School
2
Karrikattu kuppam
Karrikattu kuppam
Early Warning System located in
Evacaucation shelter
3
Muttukadu
Muttukadu
Early Warning System located in
Evacaucation shelter
4
Kovalam Kuppam
Kovalam Kuppam
Early Waring System located in
Kovalam Meenavar Panchayat
Building
5
Semmancheri Kuppam
Semmancheri
Kuppam
Early Waring System located in
Community Hall
Nemmelikupam
Nemmelikupam
Early Waring System located in a
separate Building
Pudhukalpakkam
Pudhu
kalapakkam
Early Waring system located in
Community Hall
Sulerikattu Kuppam
Sulerikattu
Kuppam
Early Waring System located in
Community Hall
9
Puttipulam kuppam
Puttipulam
kuppam
Early Warining System located in
Community hall
10
Pudhu Edaiyurkuppam
Pudhu
Edaiyurkuppan
Early Warining System located in
Community hall
11
Salavan kuppam
Salavan Kuppam
Early Warining system located in
community centre
12
Pudhu Nemmeli
Pudhu Nemmeli
Early Warining system located in
community centre
6
7
8
Chengalpattu
1
Section VI. Employer’s Requirements
2-167
Devaneri Kuppam
Deveneri Kuppam
14
Mamallapuram
Kuppam
Mamallapuram
Kuppam
Community Hall
Venpursham
Kuppam
Venpursham
Kuppam
Community Hall
Kokkilamedu
kuppam
Kokkilamedu
kuppam
Community Hall
Meiyur kuppam
Meiyur kuppam
Community Hall
Kalpakkam
Kalpakkam
Township area no kuppam
19
Sadras Kuppam
Sadras Kuppam
Community Hall
20
Pudhupattinam
Kuppam
Pudhupattinam
Kuppam
Community Hall
21
Uyyalikuppam
Uyyalikuppam
Community Hall
22
Kadalur
Chinnakkuppam
Kadalur
Chinnakkuppam
CMCT building
23
Kadalur
Periyakuppam
Kadalur
Periyakuppam
Community Hall
Kadalur
Aalikuppam
Kadalur Aalikuppam
Community Hall
Kanathurkuppam
Kanathurkuppam
Located in Kanathur Angalamman
kuppam
Vadapattinam
Kuppam
Venpursham
Kuppam
Community Hall
16
17
18
24
25
26
Cheeyur
15
Thirukazhukundram
13
Community Hall
2-168
Section VI. Employer’s Requirements
Thenpattinam
Kuppam
Thenpattinam
Kuppam
Community Hall
28
Perunduravu
Perunduravu
Early Warning System in Palvadi
school
29
Paramankeni
Kuppam
Paramankeni
Kuppam
Early Warning System in tsunami
shelter
30
Mudaliar Kuppam
Mudaliar Kuppam
31
Thazhuthalikuppam
Thazhuthalikuppam
32
Panaiyur China
Kuppam
Panaiyur China
Kuppam
33
Panaiyur Periya
Kuppam
Panaiyur Periya
Kuppam
Community Hall
34
Vilambur Kuppam
Vilambur Kuppam
No habitation
35
Kadappakkam
Kadappakkam
36
Alambarai Kuppam
Alambarai Kuppam
Early Warning system available in
Evacuation shelter lie within
500mts.
37
Muttukadu
Muttukadu
38
Kottivakkam
kuppam
Panchayat Office Building
Kottivakkam.
39
Pallavakkam
kuppam
Panchayat Office Building
Pallavakkam.
40
41
42
Showinganalur
27
Periya Neelangarai
Chinna
Neelangarai
The three kuppams lie within
100mts distance.
Early Warning System available
Panchayat Union Elementary School
working condition
Panchayat Office Building,
Neelangarai lie within 800 mts.
Injambakkam
Panchayat Office Additional Building
Chinnandikuppam
Govt. High. School, Uthandi
44
Panaiyurkuppam
Community centre, Panaiyurkuppam
45
Nainarkuppam
Community centre, Nainarkuppam
43
Section VI. Employer’s Requirements
2-169
District: Villupuram
S.No
Taluk
Village
Habitation
Place of Installation
(1)
(2)
(3)
(4)
(5)
Kottakkuppam
Thanthiriyankkuppam
Thanthiriyankippam S.No. 133/17A.
Trauma Care & Recreation club
Kottakkuppam
Chinnamudaliarchavadi
Community Hall East side Tiled Building
S.No.124/6
Bommaiyarpalayam
Bommaiyarpalayam
Panchayat Office Building S.No.359/2
4
Bommaiyarpalayam
Pillaichavadi
Pillaichavadi Trauma Care& Recreation
Club S.No.323/13A
5
Marakkanam (N)
Azhagankuppam
Tyrauma Care
6
Marakkanam (N)
Vasavankuppam
ICDS Building
7
Marakkanam (S)
Ekkiyarkuppam
Community Hall
8
Marakkanam (S)
Mandavaipudukuppam
Temple
Panichamedu
Panichamedu
Community Hall
Anumandhai
Anumandhaikuppam
Community Hall
Chettikuppam
Chettinagar
Trauma Care
Koonimedu
Notchikuppam
Community Hall
13
Koonimedu
Koonimedukuppam
Community Hall
14
Keezhputhupattu
Anichankuppam
Community Hall
15
Keezhputhupattu
Keezhputhupattu,
Pudukuppam
Noon Meal Centre (Separate is
available)
3
9
10
11
12
Tindivanam
2
Vanur
1
2-170
Section VI. Employer’s Requirements
List of Location of Early Warning System
District: Cuddalore
S.No
Taluk
Village
Habitation
Place of Installation
(1)
(2)
(3)
(4)
(5)
1
Cuddalore
Nallavadu
Nallavadu
Panchayat Union Elementary
School
2
Cuddalore
Devanampattinam
Devanampattinam
Municipal School
Cuddalore
Singarathoppu
1. Singarathoppu,
2. Sonnamkuppam
3. Akkaraigori
Municipal Middle School
4
Cuddalore
Sothikuppam
Sothikuppam
5
Cuddalore
Rasapattai
Rasapettai
6
Cuddalore
Chithrapattai
Chitharaipettai
7
Cuddalore
Thamanampattai
8
Cuddalore
Nakayarpattai
Thamanampettai
Nakayarpattai,
Najalingampattai
Community Hall
9
Cuddalore
Periyakuppam
Periyakupam, Pattodai
Cyclone Shelter
10
Cuddalore
Ayyampattai
11
Cuddalore
Anappanpattai
Community Hall
Panchayat Union Elementary
School
12
Chidambaram
Kumarappattai
13
Chidambaram
Velainkirayanpattai
14
Chidambaram
C.Pudupattai
Ayyampattai, Maniyarpattai
Anappanpattai,
Raddiyarpattai
Periyapattu, Periyandikozhi,
Thakkanpalayam,
Gopalapuram,
Kumarappattai,
Madavapallam
Villiyanallur, Puduchithiram,
Velinkirayanpattai,
V.pachayankuppam
Ariyakozhiti, Chinoor (North),
Chinoor (South), Indira
Nagar, Karikuppam,
Thoppuirrupu,
C. Pudupatti
15
Chidambaram
Pinnathoor (East)
Pinnathoor (East)
Community Hall
16
Chidambaram
Pinnathoor (West)
17
Chidambaram
Pinnathoor (West)
Thillaividangan
(South)
3
Thillaividangan (South)
Panchayat Union Elementary
School
Panchayat Union Elementary
School
Panchayat Union Elementary
School
Community Hall
Community Hall
Panchayat School Building
Cyclone Shelter
Panchayat Union Building
Section VI. Employer’s Requirements
2-171
18
Chidambaram
Killai (South)
Killai (South)
Community Hall
19
Chidambaram
Minnavar Colony
Community Hall
20
Chidambaram
Minnavar Colony
Killai (South)
Kuchipalayam
Kuchipalayam
Community Hall
21
Chidambaram
Thikkal
Community Hall
22
Chidambaram
Edappalayam
Community Hall
23
Chidambaram
Killai (South) Thikkal
Killai (South)
Edappalayam
Killai (South)
Chingarakuppam
Chingarakuppam
Community Hall
24
Chidambaram
Nakkravandankudi
Nakkravandankudi
Panchayat Union Building
25
Chidambaram
B.Maduvangkarai
B.Maduvangkarai
Panchayat Union Building
26
Chidambaram
Jayakondapattinam
Cyclone Shelter
27
Chidambaram
Jayakondapattinam
AkkaraiJayakondapattinam
Akkarai- Jayakondapattinam
Cyclone Shelter
28
Chidambaram
29
Vallampadugai, Vellakudi
Community Hall
Chidambaram
Vallampadugai
VallampadugaiVallathurai
Vallathurai
Govt. High, Sec. School
30
Chidambaram
Malathirukzhipalai
Malathirukzhipalai
Panchayat Union Building
31
Chidambaram
Kanagarapattu
Kanagarapattu
Cyclone Shelter
32
Chidambaram
Kezhiperambai
Kezhiperambai
Cyclone Shelter
33
Chidambaram
34
Chidambaram
35
Chidambaram
Pichavaram
Keezhperamabai
and
Keezhthirukazhipala
i
(Chinnakaaraimedu,
Veerankoithittu
Pichavaram Tourist
Chennai
36
Chidambaram
Kothattai
KillaiTown Panchayat Office
Self Help Group Office
Pudukuppam
37
Chidambaram
Samiyarpettai
Cyclone Shelter Semiyarpettai
38
Chidambaram
Periyapattu
Community Centre
39
Chidambaram
Mudasalodai
Government School
40
Chidambaram
Muzhukuthurai
Government School
41
Chidambaram
42
Kattumannarkoil
Melthirukazhipalai,
Kavarapatu
Jahakondampasttin
am
Panchayat Officer,
Kavarapattu
Panchayat Officer Cyclone
shelter
Panchayat Office
Panchayat Office
(Veerankoilthittu)
2-172
Section VI. Employer’s Requirements
43
Kattumannarkoil
Keezhakkundalaadi
Cyclone Shelters Ammankoil
44
Kattumannarkoil
Vallambadugai
Panchayat Oficer
45
Kattumannarkoil
Agranallur
Panchayat Oficer
46
Kattumannarkoil
Vadakku mangudi
Old Water Tank
47
Kattumannarkoil
Nandhimanagalam
Panchayat Office
48
Kattumannarkoil
Elleri
Panchayat Office
49
Kattumannarkoil
Thirunaraiyur
Panchayat Office
50
Kattumannarkoil
Naanjalur
Panchayat Office
51
Kurinjipadi
Thiyagavalli
52
Kurinjipadi
Thiruchopuram
Panchayat Office
Cyclone Shelter,
Periyakuppam
53
Kurinjipadi
Kayalpattu
Cyclone Shelter, Iyyampettai
54
Kurinjipadi
Vandiampallam
Pachanyat Office
55
Kurinjipadi
Pudhampaadi
Pachanyat Office
56
Kurinjipadi
Sirupaalaiyur
Pachanyat Office
57
Kurinjipadi
Kothavaheri
Pachanyat Office
58
Kurinjipadi
Kundiyamallur
Pachanyat Office
59
Kurinjipadi
Adoor Agaram
Pachanyat Office
60
Kurinjipadi
Arangamangalam
Pachanyat Office
61
Kurinjipadi
Kalkunam
Pachanyat Office
62
Chidambaram
Miralur
Pachanyat Office
63
Chidambaram
Agara alampadi
Pachanyat Office
64
Chidambaram
Sethiathope
E.O Office
65
Virudhachalam
T. Pavalangudi
Pachanyat Office
66
Virudhachalam
Karkudal
Pachanyat Office
67
Virudhachalam
Ko.Adhanur
Panchayat Union
68
Virudhachalam
Su. Keeranur
Pachanyat Office
69
Virudhachalam
Siruvarapur
Pachanyat Office
70
Virudhachalam
Thevangudi
Pachanyat Office
71
Chidambaram
Cholatharam
Pachanyat Office
Section VI. Employer’s Requirements
2-173
72
Chidambaram
Santhamangalam
Pachanyat Office
73
Cuddalore
Thazhanguda
Cyclone Shelter
74
Cuddalore
Rasapettai
Cyclone Shelter
75
Cuddalore
Nanamedu
VAO Office
76
Cuddalore
Sonanchaadi
VAO Office, Semmankuppam
77
Panruti
Thiruvamoor
Panchayat Office
78
Panruti
Elanthampattu
Panchayat Office
79
Panruti
Sirugramam
Gov. Hog. Sec. School
80
Kattumannarkoil
Shantan
Over Head Tank, Shantan
81
Kattumannarkoil
Kokarasanpettai
Over Head Tank, Anandakudi
82
Kattumannarkoil
Edaiyar
Panchayat Office
83
Kattumannarkoil
Kudaliyathur
Panchayat Office
84
Kattumannarkoil
Kanjankollai
Over Head Tank, Kandairrupu
85
Kattumannarkoil
Gunamanagalam
Panchayat Office
86
Kattumannarkoil
Azhankaathaan
Panchayat Office
2-174
Section VI. Employer’s Requirements
District: Nagapattinam
S.No
Taluk
Village
Habitation
Place of Installation
(1)
(2)
(3)
(4)
(5)
Thennam Pattinam
Mela Moovarkarai
RS No. 340/1A1 Community Building
(Natham)
2
Thennam Pattinam
Padasalai Street
RS.No.159/3 ADW Primary School
Building
3
Perunthottam
Cavadikuppam
RS No. 442/5A Community Building
(Natham)
4
Perunthottam
Naickarkuppam
RS. No.503 Community Building
(Natham)
5
Kaveripoompattinam
Pudukuppam
RS No. 72/1A1 SOS Community
Building
6
Kaveripoompattinam
Keelaiyur
Community Building
7
Kaveripoompattinam
Manthakarai
RS No. 365/2A Panchayat board
Building
8
Kaveripoompattinam
Neithavasal
Anganvadi Building
Kaveripoompattinam
Kaveripoom Pattinam
RS No. 402/1 Library Building
Kaveripoompattinam
Meenavar Colony
Library Building
11
Vanagiri
Vanagiri Kuppam
RS No. 403/7A Panchayat Union
Middle School
12
Vanagiri
Thosai kulam
RS No. 239/8 Community Building
13
Pudupattinam
Pazhayar Dharkas
Pan. Union Primary School Building
14
Thennampattinam
Konayampattinam
RS No.320/1 (Natham) Near Kannikoil
Community Hall (Door No.3/242)
15
Thennampattinam
Kizhamoovarkarai
RS.No.329/1A2B Tsunami Nagar
Community Hall (Door No.4/228A)
16
Thandavankulam
Chinnakottaimedu
Rs.No.30/1A1 Community Hall
17
Vettankudi
Koozhaiyar
Pan. Union Primary School Building
9
10
Sirkali
1
Section VI. Employer’s Requirements
2-175
Manickapangu
Manickapangu
RS No. 205 Panchayat board
Building
19
Manickapangu
Anaikoil
RS No. 220/2 Panchayat board
Elementary School Building
Kalamanallur
Chinnamedu
RS No. 111 Panchayat board
Building
Chandrapadi
Chinnoorpettai
RS No. 595/1 Panchayat Union
Elementary School Building
Maruthampallam
Chinnangudi
(Maruthampallam)
RS No. 182/20 Panchayat board
Building
Pillaiperumal Nallur
Thazhampettai
(Pillaiperumalnallur)
RS No. 409 Pachanyat board
Building
24
Tharangambadi
Sathangudi
Community Building
25
Tharangambadi
Kuttiyandiyur
Fisherman community Building
26
Tharangambadi
Tharngambadi
Town Panchayat Office,
Tharngambadi
27
Panagudi
Panagudi
RS No.226/2D Community Hall
Akkaraipettai
Keechankuppam
R.S.No.1/3 (Natham ) Community
Building
Akkaraipettai
Akkaraipettai
Rs.No.5/1 Panchayat Board
Building
(Door No.3/356)
Nagapattinam Town
Nagapattinam Town
TATA Nagar Tsunami House Site
Nagapattinam Town
Sambathottam
Amirtha Nagar Tsunami Housing
Community Building
32
Nagapattinam Town
Mahalakshmi Nagar
Community Hall
33
Velankanni Town
Panchayat
Velankanni
Town Panchayat office Building
Velankanni
Pookkaratheru
RS No.5 Community Building
Velankanni
Ariya Nattu Street
RS No.100 (POB) Fisherman
Community Building
Thirupoondi East
Thirupoondi East
RS No.104 Panchayat Board
Building
22
23
28
29
30
31
34
35
36
Nagapattinam
21
Kilvelur
20
Tharangambadi
18
2-176
Section VI. Employer’s Requirements
Thirupoondi East
Thirupoondi East,
Manalmedu
RS No.224/9 (Dry), Punitha Valan
Govt. Aided Primary School.
38
Pudupalli
Pudupalli
RS No. 329/5A Panchayat Building
(Door No. 2/355)
39
Vizhunthamavadi
Vizhunthamavadi
RS No 53/1 Panchayat Building
(Door No. 4/721/2)
40
Vizhunthamavadi
Vizhunthamavadi
RS No 174/3A (Manavari Dry) Pan.
Union Middle School
41
Vettaikaraniruppu
Vettaikaraniruppu
RS No. 52/2 Pachayat Building
(Door No. 2/142/2)
42
Prathaparamappuram
Seruthur
RS No. 10/15 (Ellaiyamman koil) Pan.
Union Primary School Building.
43
Vedaranyam
Mottandaithoppu
RS No. 156 Anganvadi Building
44
Vedaranyam
Poovanthoppu
RS No. 139/3B Community Building
45
Kodiyayakadu
Kodiyayakadu
RS No. 34/7 Panchayat Board
Building
46
Voimedu
Voimedu
RS No. 243/13C Panchayat Board
Building
47
Vellapallam
Vanavanmahadevi
RS No. 111/1 Panchayat Marriage
Building
(Door No. 1/245/1)
Vellapallam
Vellapallam
RS No. 154/2B & 3A (Dry)
Panchayat Building
Kovilpathu
Kovilpathu Melakadu
RS No. 48/6 (Meikal Poramboke)
Community hall
Panchanathikulam
Middle
Panchanathikulam
Middle
RS No. 141/7B Panchayat Board
Building
(Door No. 3/119)
51
Thennadar
Thennadar
RS No. 61/2 (Kulam Poramboke)
Library Building (Door No.2/102)
52
Pannal
Pannal
RS No. 118/11C Government land
Cyclone Building (Door No.4/106)
53
Periyakuthagai
Periyakuthagai
RS No. 162/3A (Dry waste
)Panchayat Building
54
Kollitheeveu
Kollitheeveu
Anganvadi Building
48
49
50
Vedaranyam
37
Section VI. Employer’s Requirements
2-177
District: Tiruvarur
S.No
Taluk
Village
Habitation
Place of Installation
(1)
(2)
(3)
(4)
(5)
2
3
4
Thiruthuraipoondi
1
Thillaivilagam
Koviladi
President Office, Thillaivilagam
Jambuvanodai
Therkkukadu
President Office,
Jambuvanodal
Karpaganartharkulam
Pannaisethi
President Office,
Karpaganatharkulam
Thondiakkadu
Munakgadu
President Office,
Thondiyakadu
5
Idumbavanam
6
Vilangadu
2-178
Section VI. Employer’s Requirements
District: Thanjavur
S.No
Taluk
Habitation
(1)
(2)
(3)
Place of Installation
(4)
Village Administrative Officer
office
163 Thambikkooitai vatakatu
2
160 Thambikkooitai meelakkatu
Panchayat Union Office
3
161 Thambikkooitai Maravakkatu
Panchayat Union Office
4
157 Thamarakoottai South
Panchayat Union Elementary
School, Karizhakadu
Pazhasur
Panchayat Union Elementary
School, Narasingapuram
153 Athirampattanam
Community Hall, Karaiyurtheru
149 Earipurakkarai
Panchayat Union Office
147 Rajamatam
Panchayat Union Middle School
9
144 Koollukadu
Panchayat Union Office
10
142 Puthupattinam
Panchayat Marriage Hall
11
136 Kallivayal
Panchayat Union Office
12
Karisavayal
Community Hall
13
85 Kuppadevan
14
84 Thiruvandevan
15
68 Senthalai vayal
Panchayat Union Office
67 Ataikkan Devan
Village Administrative Officer
office
Sambaipattinam (Rayunthan
Vayal)
Panchayat Union Office
57 Seethupava Saththiram
Village Administrative Officer
office
Marakavalasai
Panchayat Union Elementary
School
6
7
8
16
17
18
19
Parayvurani
5
Pattukottai
1
Village Administrative Officer
office
Village Administrative Officer
office
Section VI. Employer’s Requirements
2-179
District: Pudukottai
S.No
Taluk
Village
Place of Installation
(1)
(2)
(3)
(4)
Alaganvayai
VAO Quarters
2
P.R. Pattinam
PU Middle School
3
Krishnajippattinam
Govt. High School
4
Krishnajippattinam
Panchayat Office
5
Melasthanam
PU Middle School
6
Kandanivayai
Community Hall
7
Mumbafal
PU Elementary School
8
Pattankadu
VAO Quarters
Manamelkudi
Governement Girls High School
Vadakku Manamelkudi
PU Middle School
Vadakku
Ammapattinam
PU Middle School
Ponnagaram
PU Middle School
Avudayarpattinam
PU Middle School
14
Ammappattinam
Govt Girls High School
15
Ammappattinam
Primary Health Center
16
Pudukkudi
PU Middle School
17
Kottaippattinam
Revenue Inspector Quarters
18
Jagathappattinam
PU Middle School
19
Palakkudi
PU Middle School
20
Kumaraparrayal
PU Middle School
9
10
11
12
13
Manamalkudi
1
2-180
Section VI. Employer’s Requirements
Gopalappattinam
PU Middle School
22
Gopalappattinam
Government High Secondary School
23
Mimisal
Government High Secondary School
Mimisal
PU Elmentary School
R. Puduppattinam
Muslim Middle School
R. Puduppattinam
PU Elementary School
Arasanagarippattinam
PU Middle School
Kadavakkottai
PUM Elementary School
29
Muthukkuda
Saraswathi Vithyalaya Elementary
School
30
Enathi
PU Elementary School
24
25
26
27
28
Avudayarkoil
21
Section VI. Employer’s Requirements
2-181
District: Ramanathapuram
S.No
Taluk
Village
Habitation
Place of Installation
(1)
(2)
(3)
(4)
(5)
Athiyoothu
Athiyoothu,
P.U.Elementary School, Athiyoothu
2
Pathanethi
Vennathoor
U. Elementary School, Muthuthogunathapuram
3
Kalanikkudi
Kalanikkudi
P.U. Elementary School, Kalanikkudi
4
Devipattinam
Devipattinam
P.U. Elementary School, Devipattinam
5
Chithrakottai
Chithrakottai
P.U. Elementary School, Mudiveeranpattinam
6
Periyapattinam
Periyapattinam
P.U. Elementary School, Pudhukudiyiruppu
7
Thirupplani
Sethukarai
Community Hall
Thinaikulam
Thinaikulam
Panchayat Union office Building
Kalaimankundu
Kalimankundu
Panchayat Union office Building
Attrankarai
Attrankarai
P.U. Elementary School, Attrankarai
Keelanagachi
Keelanagachi
P.U.Elementary School, Kalkinatruvalasai
12
Pudhumadam
Pudhumadam
Govt. Hr.Sec. School, Pudhumadam
13
Enmanagkonda
Enmanamkondan
P.U. Elementary School, Dharkavalasai
14
Pirappancalasai
Irumeni
P.U. Elementary School, Irumeni
15
Sathakonvalasai
Sathakonvalasai
P.U. Elementary School, Szthkonvalasa
Seeniyapa Tharga
16
Notchiyoorani
Notchiyoorani
P.U. Elementary School, Notchiyoorani
17
Notchiyoorani
Manangudi
Panchayat Office, Soorankanvalasi
18
Mandapam
Vedhalai
P.U. Office Building, Vedhalai
8
9
10
11
Ramanathapuram
1
2-182
Section VI. Employer’s Requirements
19
Mandapam
Marikayarpattinam
P.U. Office Building, Maraikayarpattinam
20
Mandapam
Mandapam
P.U. Elementary School, South Coast
21
Therbogi
Pudhuvalasai
P.U. Elementary School, Kadarkaraichathiram
22
Karan
Karan
P.U. Elementary School, Thalaiyothu
23
Alagankulam
Panaikulam
P.U. Elementary School, Sokaiyanthopu
24
Akagabjykan
Ananthapuram
chathiram
P.U. Elementary School, Andhapuram
Chathiram
25
Thamarikulam
Thamarikulam
Govt. Higher Secondary School,
Thamaraikulam
26
Manadapam
Idhaiyarvalasai
P.U. Elementary School, Idaiyarvalasai
27
Kilakarai
Kilakarai
Municipal Office Building, Kilakarai
28
29
30
Sangumal,
Oalikuda, Mandi
Street,
Agasthiyartheertha
m, Sherankottai,
Kothandaramar
Koil street,
Thanvukadu,
Mugantharayar
chathiram, Beach
Mariyammman
street, Old Market
street, Kariyuer,
Verkodu,
Maruthupandiya
nagar, Masque
street,
Santhanamariyam
man koil street
Akkalmadem,
Light House
Street, Murugan
Koil Street,
Therkuvadi Nadu
Street, Kundhukal,
Pattlathar Street,
Jail Street,
Chinnapalam,
Vadakadu
Manthopu,
Soosaiyappeerpatt
inam, Victoriya
nagar,
Antoniyarpuram,
III - Municipality Office Building, Rameswaram
S.No.7091/1
Panchayat Office Building Akkalamadem
S.No.869/7
Section VI. Employer’s Requirements
2-183
Peikarumbu,
Thanir Ottur,
Francis Nagar,
Kamaraj Nagar,
Sethupathi nagar,
Ariyankundu,
Valasai
Pudupattinam
Karankadu
Panchayat Building
32
Pudhupattinam
Pudupattinam
Panchayat Building, Pudupattinam
33
Mullilunai
Mullimunnai
Pachayat Building, Mullimunnai
34
Nambithalai
Nambuthalai
Pachayat Building, Nambuthalai
35
Kanattankudi
Choliyakudi
Pachayat Building, Choliyakudi
36
Thondi
Thondi
Town Panchayat Building, Thondi
Thirupalakudi
Thirupalakudi
Panchayat Building, Thirupalakudi
Uppoor
Uppoor
Panchayat Building, Kadalur
Marungur
Marungur
Panchat Building, S.P. Pattinam
Kaliyanagari
Kaliyanagari
Panchat Building, Kaliyanagari
41
Vattnam
Pullukadambam
Pullukadambam Panchayat Building, at Irrupu
Theerthandathanam
42
Vattanam
Vattanam
Panchayat Building, Vattanam
43
Kodipangu
Kodipangu
Panchayat Building, Kodipangu
Kadalur
Panchayat Union Elementary School
37
38
39
40
Thiruvadanai
31
44
Uppoor
Morepannai
Panchayat Union Elementary School
46
M.R.Pattinam
M.R. Pattinam
Panchayat Union Elementary School
47
M.R.Pattinam
Keelamunthal
P.U. Middle School, Keelamunthal
48
Mookaiyur
South Mookaiyur
Panchayat Building, South Mookaiyur
Erawadi
Chinna Erawadi
Cyclone Centre, Sadimunian Valasai
Narippaiyur
South Naripaaiyur
Cyclone Centre, Narippaiyur
Kannirajapuram
Kannirajapuram
Cyclone Centre, Kannirajapuram
49
50
51
Kaaladi
45
2-184
Section VI. Employer’s Requirements
Valinokam
Valinokam
Panchayat Union Building, Valinokam
53
Periyakulam
T.Mariyur
Panchayat office
54
Periyakulam
Opplian
Panchayat Office
55
Periyakulam
Kovil Mariyur
Cyclone Centre
56
Erwadi
Erwadi /
Muthurayar Nagar
Panchayat Union Elementary School
57
Erwadi
Erwadi / Adancheri
Panchat Union Elementary School
58
Mookaiyur
Mookaiyur /
Kannigapuri
Panchayat Union Elementary School
59
Mookaiyur
Mookaiyur /
Kudhuraimozhi
Panchayat Union Elementary School
60
Narippaiyur
Narippaiyur /
Thiravyapuram
Magalire Mandram Building
61
Narippaiyur
Narippaiyur
TWAD Building
62
63
64
Ramanathapuram
52
Changalneerodai
village,
Kancheerangkudi
kurupu
Pakkiyaraba
masque,
Kancheerangkudi
kurupu
Marayakulam
kurupu
Magalire Mandram Building
Magalire Mandram Building
Panchayat Union Middle School
Section VI. Employer’s Requirements
2-185
District: Thoothukudi
S.No
Taluk
Village
Habitation
Place of Installation
(1)
(2)
(3)
(4)
(5)
Vaippar II
Keelavaippar, Sippikulam,
Ahamathupuram,
Srivaikundaperumaipuram
Panchayat Building
Vembar
vembar
Panchayat Building
Vembar South
Vembar
vembar
SSA School Building
Vember North
4
Perisamypuram
Perisamypuram, Muthiyapuram,
Kunjayappuram
SHW Building
5
Keela
Tiruchendur
Amalinagar, Alanthalai,
Jeeva Nagar
Highways Office
6
Veerapandiyan
patinam
Veerapandiyan patinam
Panchayat Office
Kayalpattinam
South
Kayalpattinam, Mangalavadi,
Singithurai, Kormbuthurai
Municipal Office
Kayalpattinam
Punnakayal
Punnakayal
Panchayat Office
9
Manapadu
Manapadu
Panchayat Office
10
Kulasekara
Pattinam
Kulasekara pattinam,
Sirunadarkudiyeruppu
Panchayat Office
11
Keela Arasadi
Vellapatti
Public Library
Pattanamaruthur
Palarpatti
Panchayat Office
Tharuvaikulam
Tharuvaikulam
Panchayat Office (RASI
Center)
7
8
12
13
Tiruchendur
3
Ottapidaram
2
Vilathikulam
1
14
Section VI. Employer’s Requirements
Sattankulam
2-186
Periathalai
Panchayat Office Building
Thoothukudi
Thoothukudi
Corporation Office Building
Mappillaiyurani
Mappillaiyurani,
Siluvaipatti
Panchayat Office
17
Thoothukudi
Thoothukudi
18
Thoothukudi
Thoothukudi
19
Mullakkadu
Mullakkadu
15
16
Thoothukudi
Padukkapathu
Thereshpuram Joint
Director (Fisheries)
(Regional) Office
Assistant Director of
Fisheries, (Marine) Office
Panchayat Office
Section VI. Employer’s Requirements
2-187
District: Tirunelveli
S.No
Taluk
Village
Habitation
Place of Installation
(1)
(2)
(3)
(4)
(5)
Levinjipuram
Kuttapuli
Father's House
Kuttapuli
2
Chettikulam
Perumanal
Father's House
Perumenal
3
Vijayapathi
Idinthakarai Casa
Colony
Evacuation Shelter built by CASA
Idinthakarai
4
Vijayapathi
Idinthakarai
Panchayat Office, Idinthakarai
5
Vijayapathi
Thillsivanamthoppu,
Thomaiyarpuram,
Avaudiyalpuram
Panchayat Union Elementary
Thomaiyapuram
6
Thiruvembalapuram
Kuthankuli,
Fathima Nagar
Panchayat Office,
Kuthankuli
7
Karaisuttuputhur
Navvaladi,
Vallanvilai
Government Library Building,
Navvaladi
Karaisuttuputhur
Marakkasttuvilai,
Sempovilai,
Kodavilai,
Kalikumarapuram
C.S.I. Church, Marakkattuvilai
Karaisuttu Ovari
Ovari
Panchayat Office, Ovari
Kariaisuttu Ovari
Keelakovari / Mela
vari
Panchayat Ofice, Mela Ovari
11
Kariaisuttu Ovari
Karikovil,
Kundal
Community Hall, Karikovil
12
Kuttam
Annanagar
Kuttapanai
Community Hall, Kuttapanai
13
Kuttam
Kuttapai, Kuduthalai
St. Thomaiyar Church,
Kuduthalai
14
Kuttam
Pariyathalai,
Thoppailai
Evacuation Shelter Built by CASA
15
Chettikulam
Chettikulam
Panchayat Union office
16
Chettikulam
Anuvijaynagariyam,
Sirranganarayanapu
ram
Anuvijayanagar welfare assocation
building
17
Vijayapathi
Mela vijayapathi
Kela vijayapathi
Panchayat Union Elementary
School, Kela vijayapathi
8
9
10
Radhapuram
1
2-188
Section VI. Employer’s Requirements
18
Kariaisuttupudur
19
Kuttam
20
Irukkanthurai
Kalaikumarapuram
Panchayat Union Elementary
School,Kalaikumarapuram
Panchal
CSI Chruch Building Panchal
Section VI. Employer’s Requirements
2-189
District: Kanniyakumari
S.No
Village
Habitation
Place of Installation
(1)
(2)
(3)
(4)
1
Arokiyapuram
Arokiyapuram
Primary Health Centre
2
Chinna Muttom
Chinna Muttom
Office of A.D. Fisheries,
Fishing Harbour Project,
Chinnamuttom
3
Kanniyakumari
KanniyaKumari
Village Office, Kanniyakumari
4
Kovalam
Kovalam
Panchayat Office, Kovalam
5
Melamanakudy
Melemanakudy
Panchayat Office
6
Pallam
Pallam
Panchayat Office, Pallam
7
Kesavanputhenthurai
Kesavanputhenthurai
Panchayat Office,
Kesavanputhethurai
8
Rajakkamangalamthurai
Rajakkamangalamthurai
Primary Health Centre,
Rajakkamangalamthurai
9
Azhikkal
Azhikkal
Primary Health Centre Azhikkal
10
Muttom
Muttom
Panchayat Office, Muttom
11
Chinnavilai
Chinnavilai
Town Panchayat Office Building,
Manavalakurichi
12
Kadiyapattinam
Kadiyapattinam
Govt. Library building,
Kadiyapattinam
13
Mondaicaduputhoor
Mondaicaduputhoor
Community Hall, Puthoor
14
Kottilpadu
Kottilpadu
Community Hall,
EFICOR Building,
Kottilpadu
15
Colachel
Colachel
Municipal Office Building, Colachel
16
Vaniyakudi
Vaniyakudi
Panchayat Office, Simon colony
17
Kurumbanai
Kurumbanai
Fair Price Shop Building,
(Meenavar Co-operative Society),
Kurumpanai
18
Melmidalam
Melmidalam
Govt. Primary School, Melmidalam
2-190
Section VI. Employer’s Requirements
19
Enayam
Enayam
Community Hall,
Enayam of Keezhkulam Village
20
Enayam Puthenthurai
Enayam Puthethurai
Panchayat Office, Enayam
21
Ramanathurai
Ramanthurai
Community Hall, Ramanthurai
22
Mulloorthurai
Mulloorthurai
Primary Health Centre,
Mulloorthurai
23
Thengapattinam
Thengapattinam
Primary Health
Centre,Thengapattinam
24
Erayumanthurai
Erayumanthurai
Govt. Library,Erayumanthurai
25
Poothurai
Poothurai
Panchayat Office, Poothurai
26
Thoothoor
Thoothoor
Primary Health Centre, Thoothoor
27
Thoothoor Chinnathurai
Thoothoor Chinnathurai
Government Library Building,
Thoothoor Chinnathurai
28
Vallavilai
Vallavilai
Primary Health Centre, Vallavilai
29
Marthandamthurai
Marthandamthurai
Government Library Building,
Marthandamthurai
30
Neerodi
Neerodi
Noon Meal Centre, Neerodithurai
31
Mugilankudiyiruppu
Mugilankudiyiruppu
Government Library Building
32
Osaravilai
Osaravilai
Government Library Building
33
Periacadu
Periacadu
Community Hall
Section VI. Employer’s Requirements
2-191
Attachment - 2
Name of the Equipment
Sl.No
Specification provided in the Specification of the Remarks
Bidding document by Employer
alternative Equipment
proposed
by
the
Bidder
2-192
Section VI. Employer’s Requirements
Form of Completion Certificate
Date:
Loan/Credit No:
IFB No:
______________________________
To: _________________________________
Dear Ladies and/or Gentlemen,
Pursuant to GC Clause 24 (Completion of the Facilities) of the General Conditions of the
Contract entered into between yourselves and the Employer dated _____________, relating to the
____________________, we hereby notify you that the following part(s) of the Facilities was (were)
complete on the date specified below, and that, in accordance with the terms of the Contract, the
Employer hereby takes over the said part(s) of the Facilities, together with the responsibility for
care and custody and the risk of loss thereof on the date mentioned below.
1.
Description of the Facilities or part thereof: ______________________________
2.
Date of Completion: __________________
However, you are required to complete the outstanding items listed in the attachment hereto as
soon as practicable.
This letter does not relieve you of your obligation to complete the execution of the Facilities in
accordance with the Contract nor of your obligations during the Defect Liability Period.
Very truly yours,
Title
(Project Manager)