SMC Corporation Information Akihabara UDX 15F, 4-14-1, Sotokanda, Chiyoda-ku, Tokyo 101-0021, JAPAN http://www.smcworld.com ©2012 SMC Corporation All Rights Reserved 12-E586 D-SZ Printing QX 8150SZ Electric Actuator/Rod Type Series LEY AC Servo Motor (400 W) RoHS Size: 63 )Added size 63 to the LEY series! 80 kg Vertical 72 kg High output motor: 400 W Max. speed: 1000 mm/s Work load Horizontal 500 stroke Max. pushing force: 1910 (N) Added dust/drip proof specification (IP65 equivalent) Applications Lifter Offering 4 types of Incremental Type Pulse input type/ Positioning type Series LECSA AC servo motor Press fitting driver Absolute Type Pulse input type Series LECSB CC-Link direct input type Series LECSC SSCNET III type Series LECSS 1 12-E586-LEY.indd 1 12.9.27 11:14:50 AM Series LEY Speed–Work Load Graph Vertical transfer Horizontal transfer LEY63; LEY63; 100 Lead 5: LEY63;C 80 60 40 Lead 20: LEY63;A 20 0 Regeneration (100%) /High load Lead 10: LEY63;B Regeneration (50%) Regeneration (100%) /Low load 0 200 400 600 800 1000 1200 Horizontal work load [kg] Vertical work load [kg] 100 Lead 5: LEY63;C Lead 10: LEY63;B 80 60 Lead 20: LEY63;A 40 20 0 1400 0 200 400 Speed [mm/s] 600 800 1000 1200 Speed [mm/s] Required conditions for “Regeneration option” Regeneration option required when using product above “Regeneration” line in graph. (Order separately) “Regeneration Option” Models Size [How to read the graph] Required conditions changes depending on operating conditions. “Regeneration (50%)”: Duty ratio 50% or more “Regeneration (100%)”: Duty ratio 100% Regenerative conditions Vertical transfer Regeneration (50%) LEC-MR-RB-032 Horizontal transfer LEY63; Regeneration (100%)/Low load LEC-MR-RB-032 Regeneration (100%)/High load Not required LEC-MR-RB-12 Allowable Stroke Speed [mm/s] Model LEY63; Stroke [mm] Lead Symbol [mm] 600 700 800 A B C 20 1000 800 600 500 10 500 400 300 250 5 250 200 150 125 (3000 rpm) (2400 rpm) (1800 rpm) (1500 rpm) 400 W/;60 100 200 (Motor rotation speed) Force Conversion Graph 2000 1800 1600 Force [N] 1400 Lead 5: LEY63;C 1200 1000 Lead 10: LEY63;B 600 400 Lead 20: LEY63;A 200 0 10 20 30 400 500 Graph of Allowable Lateral Load on The Rod End LEY63; (Motor mounting position: In-line) 800 300 40 50 60 Allowable lateral load on the rod end: F (N) AC servo motor 100 LEY63 10 1 0 100 200 300 Torque limit/Command value [%] Torque limit/Command value [%] Duty ratio [%] 400 500 600 700 800 900 1000 Stroke [mm] Continuous pushing time [minutes] 25 or less 100 — 30 100 (60) — (1.5) 40 50 (30) 1.5 (0.5) 50 30 (20) 0.5 (0.16) 1 The values in ( ) are for a closely-mounted driver. 2 Motor type: When limiting torque with incremental encoder, parameter No. PC12/the value of the internal torque command should be set 50% or less. 3 Motor type: When limiting torque with absolute encoder, parameter No. PC13/the value of the maximum output command for analog torque should be set 50% or less. [Stroke] = [Product stroke] + [Center of gravity] F Center of gravity 2 12-E586-LEY.indd 2 12.9.27 11:14:54 AM Electric Actuator/Rod Type Series LEY63 LEY RoHS How to Order LEY 63 D S4 B 200 S 2 A2 Size I/O connector 63 Nil Without connector H With connector Motor mounting position D In-line Cable length Note 2) [m] Lead [mm] Symbol LEY63 A B C 20 10 Nil Without cable to S R Standard cable 800 P IP65 (Dust/Drip proof specification)/ With vent hole tap Driver type When using the dust/drip proof (IP65), correctly mount the fitting and tubing to the vent hole tap, and then place the end of the tubing in an area not exposed to dust or water. The fitting and tubing should be provided separately by the customer. Select [Applicable tubing O.D.: ø4 or more, Connection thread: Rc1/8]. Compatible drivers Nil Without lock B With lock Motor type S8 Power supply voltage Without driver Nil A2 LECSA2/Pulse input type (Incremental encoder) 200 V to 230 V B2 LECSB2/Pulse input type (Absolute encoder) 200 V to 230 V C2 LECSC2/CC-Link (Absolute encoder) 200 V to 230 V S2 LECSS2/SSCNET III (Absolute encoder) 200 V to 230 V Motor option AC servo motor (Absolute encoder) Robotic cable (Flexible cable) Note 1) The motor and encoder cables are included. (The lock cable is included when the motor with lock option is selected.) Dust/Drip proof IP5x (Dust proof specification) S4 5 10 100 Nil AC servo motor (Incremental encoder) 2 Cable type Note 1) Stroke [mm] Type Without cable 2 5 A Note 2) The length of the encoder, motor and lock cables are the same. 5 100 to 800 Symbol Nil Output [W] Actuator size Compatible drivers 400 63 LECSA2-S4 Symbol Type 63 LECSB2-S8 LECSC2-S8 LECSS2-S8 Nil Ends tapped (Standard) 2 ) U F Body bottom tapped ) Rod flange ) 400 Mounting 1 Rod end thread Nil Rod end female thread M Rod end male thread (1 rod end nut is included.) Motor mounting position In-line 1 Mounting bracket is included, (but not assembled). 2 For horizontal cantilever mounting with the ends tapped and rod flange, use the actuator within the following stroke range. u LEY63: 100 or less Applicable stroke table Model Stroke (mm) LEY63 100 200 300 400 500 600 700 800 Manufacturable stroke range ) ) ) ) ) ) ) ) 50 to 800 Note) Consult with SMC for the manufacture of intermediate strokes. 3 12-E586-LEY.indd 3 12.9.27 11:14:55 AM Series LEY Specifications LEY63DS 48 ; Model Stroke [mm] Note 1) 100, 200, 300, 400, 500, 600, 700, 800 Work load [kg] Horizontal Note 2) 40 70 Vertical 19 38 72 156 to 521 304 to 1,012 573 to 1,910 Pushing force [N]/Set value Note 3) : 15 to 50% Note 4) Actuator specifications Note 5) Max. speed [mm/s] Stroke range Up to 500 1000 500 250 505 to 600 800 400 200 605 to 700 600 300 150 705 to 800 500 250 125 Pushing speed [mm/s] Note 6) 30 or less Max. acceleration/deceleration [mm/s2] 5,000 o0.02 Positioning repeatability [mm] Screw lead [mm] (including pulley ratio) 20 10 Impact/Vibration resistance [m/s2] Note 7) 5 50/20 Actuation type Ball screw + Belt [1:1]/Ball screw Guide type Sliding bushing (Piston rod) Operating temprature range [nC] 5 to 40 Operating humidity range [%RH] 90 or less (No condensation) Required conditions for regeneration option Note 8) [kg] Lock unit Electric specifications specifications 80 Horizontal Not required Not required Not required Vertical 2 or more 5 or more 12 or more Motor output/Size 400 W/;60 Motor type AC servo motor (200 VAC) Motor type S4: Incremental 17-bit encoder (Resolution: 131072 p/rev) Motor type S8: Absolute 18-bit encoder (Resolution: 262144 p/rev) Encoder Type Note 9) Non-magnetizing lock Holding force [N] 313 607 Power consumption [W] at 20nC Note 10) 1,146 7.9 Rated voltage [V] 24 VDC 0 −10% Note 1) Consult with SMC for the manufacture of strokes other than those shown above. Note 2) The maximum value of the horizontal work load. An external guide is necessary to support the load. The actual work load changes according to the condition of the external guide. Please confirm using actual device. Note 3) Set values for the driver. Note 4) The force setting range for the pushing operation with the torque control mode, etc. The pushing force and the duty ratio change according to the set value. Set it with reference to “Force Conversion Graph” on page 2. Note 5) The allowable speed changes according to the stroke. Note 6) The allowable collision speed for the pushing operation with the torque control mode, etc. Note 7) Impact resistance: No malfunction occurred when the actuator was tested with a drop tester in both an axial direction and a perpendicular direction to the lead screw. (Test was performed with the actuator in the initial state.) Vibration resistance: No malfunction occurred in a test ranging between 45 to 2000 Hz. Test was performed in both an axial direction and a perpendicular direction to the lead screw. (Test was performed with the actuator in the initial state.) Note 8) The work load conditions which require “Regeneration option” when operating at the maximum speed (Duty ratio: 100%). Note 9) Only when motor option “With lock” is selected. Note 10) For an actuator with lock, add the power consumption for the lock. Weight Product Weight [kg] LEY63DS;; Series 100 200 300 400 500 600 700 800 Incremental encoder 5.6 6.7 8.4 9.6 10.7 12.4 13.5 14.7 Absolute encoder 5.7 6.8 8.5 9.7 10.8 12.5 13.6 14.8 Motor type Stroke [mm] Additional Weight Lock Rod end male thread Size Incremental encoder [kg] 63 0.4 Absolute encoder 0.6 Male thread 0.12 Nut 0.04 Rod flange (including mounting bolts) 0.51 4 12-E586-LEY.indd 4 12.9.27 11:14:55 AM Electric Actuator/Rod Type Series LEY Construction Motor mounting position: In-line/LEY63 2 8 @ B = : ; . > When rod end male thread selected Component Parts Description No. Material Note No. Aluminum alloy Anodized 14 Motor adapter Alloy steel 15 Spacer A Stainless steel Resin/Alloy steel 16 Hub Aluminum alloy 17 Spider 18 Bushing Aluminum alloy 19 Seal Aluminum alloy 20 Bearing — 21 Lock nut Alloy steel Resin 22 Retaining ring Stainless steel 23 Motor — 24 Socket (Male thread) Resin 25 Nut 1 Body 2 Ball screw shaft 3 Ball screw nut 4 Piston Aluminum alloy 5 Piston rod Stainless steel 6 Rod cover 7 Bearing holder 8 Socket 9 Wear ring 10 Wear ring holder 11 Magnet 12 Rotation stopper 13 Motor block Free cutting carbon steel Aluminum alloy Hard chrome anodized Nickel plated Description Material Note Aluminum alloy Coating Urethane Lead bronze cast NBR Hard chrome anodized Steel for spring — Free cutting carbon steel Nickel plated Alloy steel Trivalent chromated Coating 5 12-E586-LEY.indd 5 12.9.27 11:14:56 AM Series LEY Dimensions: In-line Motor Type LEY63D; Encoder Z phase detecting position 4o1 M EH S L B + Stroke U 4 x O1 thread effective depth R ;K Note 2) øD J M T EV Z Rod operating range Note 1) (Stroke + 8 mm) ;V W A + Stroke H thread effective depth C Note 1) Range within which the rod can move. Make sure a workpiece mounted on the rod does not interfere with the workpieces and facilities around the rod. Note 2) The direction of rod end width across flats (;K) differs depending on the products. [mm] Size Stroke range [mm] 63 205 to 500 C D EH EV H J K L M O1 R S T U 21 40 76 82 M16 x 2 44 36 37.4 60 M8 x 1.25 16 78 83 5 Stroke range [mm] B V Up to 200 190.7 205 to 500 225.7 505 to 800 260.7 Up to 200 505 to 800 Size 63 Incremental encoder Without lock With lock A W Z 338.3 60 373.3 A W Absolute encoder Without lock With lock Z A 366.9 110.2 8.1 408.3 Rod end male thread/LEY63;;;-;;M 401.9 W 138.8 8.1 361.6 436.9 A W Z 138 8.1 366.1 98.5 8.1 396.6 401.1 436.1 IP65 (Dust/Drip proof specification)/LEY63D;;-;P Rc1/8 Vent hole tap 10.5 M18 x 1.5 Width across flats 27 Z 326.6 11 26 50 39 76.4 The measurement 76.4 is when the unit is in the encoder Z phase detecting position. At this position, 4 mm at the end. When using the dust/drip proof (IP65), correctly mount the fitting and tubing to the vent hole tap, and then place the end of the tubing in an area not exposed to dust or water. The fitting and tubing should be provided separately by the customer. Select [Applicable tubing O.D.: ø4 or more, Connection thread: Rc1/8]. 6 12-E586-LEY.indd 6 12.9.27 11:14:57 AM Electric Actuator/Rod Type Series LEY Dimensions: In-line Motor Type Body bottom tapped/LEY63;;;-;;U 6 x MO thread effective depth MR MH øXA H9 depth XA Section XX details MD Section XX L MA ML + Stroke XA H9 XB MC XA [mm] Size 63 Stroke range [mm] L MA MC MD 20 to 74 24 50 75 to 124 45 60.5 58 67 125 to 200 37.4 38 201 to 500 86 501 to 800 81 MH ML MO MR XA XB M8 x 1.25 10 6 7 65 44 100 135 Rod flange/LEY63;;;-;;F 92 Included parts uFlange uBody mounting bolts 80 60 28.4 4 x ø9 9 108 Material: Carbon steel (Nickel plated) 7 12-E586-LEY.indd 7 12.9.27 11:14:58 AM
© Copyright 2026 Paperzz