Construction Guide Version Index Version 1.0 1.1 Date 05.10.15 10.02.16 Issuer HY JW Amendments Made / Reason NEW & REVISED MANUAL FOR ASSESSMENT Cover Note The drawings in this document supersede previous drawing details submitted. Some of the drawings have been previously approved under different drawing numbers. Please see below: ISOSC-013B superseded by SEC/SAP/32100/REVA ISOSC-012A superseded by SEC/SAP/32200/REVA ISOSC-014B superseded by SEC/SAP/32300/REVA ISOSC-015B superseded by SEC/SAP/32400/REVA Section 1 – Introduction Securiclad Introduction/Product Information Overview of the LPS1175 scheme (SR ratings explained) Manufacturing Approval Technical Details:- Acoustic, Structural Span Detail Wall/Ceiling – Max Span Fire Approved Products By Others Health & Safety Maintenance Installation Guide Scope of Assessment: Walls/Ceilings – scope from BRE Section 2 – Panel Joint Details Wall – SR2,3,4 and Options Ceilings– SR2,3,4 and Options <3000mm Panel Detail for Double Skin Options Ceilings– SR,3,4 and Options >3000mm Re-enforced Panel Options Section 3 – Wall Details Corner Joints Partition wall with angle or channel Panel to existing (non securiclad) wall Section 4 - Ceiling Details Ceiling details Intermediate joints Ceiling supported by steel beam Section 5 -Floor Details Standard floor fixing detail Raised floor detail Dual panel fixing detail Section 6 – Joints Wall Joints Start & Finish - Including angles and fixings Panel to existing steelwork Vertical Wall Joint With Header Above Door Vertical Wall Joint Without Header above Door Section 7 - Service Penetrations Standard small penetrations Multiple service penetrations Servicing large apertures Frame out channel options Section 8 – Apertures Channel options Angle options End Post Corner Post Inline Post Section 9 – Small Enclosure Small Enclosures Locking Mechanism Section 10 – Flashings & Fixings Flashing options Fixings Section 11 – Impact of Louvers Louver options to LPS1175 DRAWING INDEX Code SEC/PAN/10000/REVA SEC/ACC/20000/REVA SEC/SAP/30000/REVA SEC/DET/40000/REVA SEC/FIX/50000/REVA SEC/APO/60000/REVA = Panel = Accessories = Securiclad Approved Product = Detail = Fixing = Approved Product By Others Drawing Section 2 Drawing Number SR2 Panel Joint Detail Wall SR2 Panel Joint Detail Ceiling SR3 Panel Joint Detail Wall SR3 Panel Joint Detail Ceiling <3000mm SR4 Panel Joint Detail Wall SR4 Panel Joint Detail Ceiling <3000mm Double Skin Panel Joint Detail Wall Double Skin Panel Joint Detail Ceiling <3000mm SR3 Ceiling >3000mm SR4 Ceiling >3000mm SR3 Reinforced Panel Wall SR3 Reinforced Panel Ceiling < 3000 SR4 Reinforced Panel Wall SR4 Reinforced Panel Ceiling < 3000 SR3 Reinforced Ceiling > 3000 SR4 Reinforced Ceiling > 3000 SEC/PAN/10000/REVA SEC/PAN/10100/REVA SEC/PAN/10200/REVA SEC/PAN/10300/REVA SEC/PAN/10400/REVA SEC/PAN/10500/REVA SEC/PAN/10600/REVA SEC/PAN/10700/REVA SEC/PAN/10800/REVA SEC/PAN/10900/REVA SEC/PAN/11000/REVA SEC/PAN/11100/REVA SEC/PAN/11200/REVA SEC/PAN/11300/REVA SEC/PAN/11400/REVA SEC/PAN/11500/REVA Section 3 Corner Post Detail Tamper Corner Post Detail Bolt Partition Wall Angle Fixed Partition Wall Channel Fixed Free Standing Wall Full Panel Free Standing Wall Narrow Panel SEC/DET/40000/REVA SEC/DET/40100/REVA SEC/DET/40200/REVA SEC/DET/40300/REVA SEC/DET/41700/REVA SEC/DET/41800/REVA Section 4 Ceiling Detail Ceiling Support Bolted Ceiling Support Tamper Ceiling Support Steel Beam SEC/DET/40400/REVA SEC/DET/40500/REVA SEC/DET/40600/REVA SEC/DET/40700/REVA Section 5 Channel Fixing Raised Floor Detail Wall Panel to Raised Floor Detail Dual Panel Floor Fix SEC/DET/40800/REVA SEC/DET/40900/REVA SEC/DET/41100/REVA SEC/DET/41200/REVA Section 6 Horizontal Wall Joint Starting Abutment Finishing Abutment Structural Steel & Panels Door with Header Panel Door without Header Panel SEC/DET/41300/REVA SEC/DET/41400/REVA SEC/DET/41500/REVA SEC/DET/41600/REVA SEC/DET/41900/REVA SEC/DET/42000/REVA Section 7 Single Penetration Multi Penetration Letterbox Set Drawing Unprotected Frame-out Channels SEC/SAP/32100/REVA SEC/SAP/32200/REVA SEC/SAP/32300/REVA SEC/SAP/32400/REVA SEC/SAP/32500/REVA Section 8 All Apertures C13 Detail C11 Detail C10 Detail A12 Detail A11 Detail A10 Detail End Post Tamper End Post Bolt Inline Post Tamper Inline Post Bolt Corner Post Bolt Corner Post Tamper SEC/SAP/30000/REVA SEC/SAP/30100/REVA SEC/SAP/30300/REVA SEC/SAP/30400/REVA SEC/SAP/30500/REVA SEC/SAP/30600/REVA SEC/SAP/30700/REVA SEC/SAP/30800/REVA SEC/SAP/30900/REVA SEC/SAP/31000/REVA SEC/SAP/31100/REVA SEC/SAP/31200/REVA SEC/SAP/31300/REVA Section 9 Small Enclosure With Header panel Small Enclosure Without Header panel Door Locking Mechanism Door Posts and Lintel SEC/SAP/31400/REVA SEC/SAP/31500/REVA SEC/SAP/31600/REVA SEC/SAP/31700/REVA Section 10 All Flashings P1 Detail P2 Detail P3 Detail P4 Detail P5 Detail Available Fixings SEC/ACC/20000/REVA SEC/ACC/20100/REVA SEC/ACC/20200/REVA SEC/ACC/20300/REVA SEC/ACC/20400/REVA SEC/ACC/20500/REVA SEC/FIX/50000/REVA Section 11 High Performance Security Ventilation Louvres SEC/APO/60000/REVA SECTION 1 INTRODUCTION Introduction to Securiclad: Securiclad is a premium modular composite panel system designed and manufactured to protect high risk areas, from data centres and government infrastructure, to utilities facility control rooms, banks, hazardous material storage sites and more. Developed to withstand determined attack from a wide range of tools and firearms, Securiclad is the ideal way to safeguard a business, facility, goods or home. Rigorously tested, it is approved for Government use by the Centre for the Protection of National Infrastructure (CPNI) and provides a high security panel solution to Loss Prevention Standard (LPS) 1175 Security Rating (SR) 2, 3 and 4. The Securiclad panel also holds the prestigious European EN1063 Ballistic Standard BR2, BR3 and BR4 certification. Securiclad Product Information: Securiclad is available in a variety of different compositions in order to satisfy a broad range of differing security requirements. Its high security level and innovative design means that it is ideal for the construction of secure environments to protect areas containing servers, sensitive data and documents, hazardous substances, high value items and pharmaceuticals. The system is quick and easy to install, with minimal disruption. It is entirely bespoke, can be designed to specification and offers a complete modular solution including wall, ceiling and floor panels – Certificate Number 142C & 142D. Securiclad is weather and water resistant, making it suitable for both internal and external applications. It can be used as a ‘standalone’ wall or partition as well as a complete modular secure enclosure. Securiclad can be installed in new buildings or retro-fitted to an existing site. Securiclad is also pre-finished, negating the need for wet or hot trade requirements. This provides a substantial cost saving in terms of materials, turnaround time and labour when compared to more traditional building methods. It is available in a wide range of core types to satisfy insulation and fire rating requirements. Securiclad can be offered as a turnkey solution, via approved and certified personnel or on a supply-only basis for contractors who prefer to install the system themselves (using this document). Securiclad can also be supplied fully assembled as a smaller kiosk, guard hut or small storage space. Securiclad provides a premium, physical security barrier which can be used wherever there is a requirement to safeguard high risk areas, protect critical equipment, or provide a last line of defence against acts of terrorism, theft or vandalism. The high security, modular composite panel solution Securiclad provides is used across a wide range of industry sectors across a broad range of applications. Securiclad overcomes a number of on-site restrictions posed by traditional building methods, it can be designed to specification and offers heightened security solutions for rooms in a building, entire external building envelopes or simply offers high security partition walls. The system has both internal and external applications. Securiclad Typical Applications: Securiclad is ideal for use in: Data centres and server rooms Utilities infrastructure Healthcare facilities Cargo areas Financial institutions Retail sites Private residences Further information can be found on the Securiclad website or by contacting Sales: Website: www.securiclad.co.uk Tel: 0191 2585052 Email: [email protected] LPS 1175: LPCB Overview LPCB (Loss Prevention Certification Board) have been setting the standards for loss prevention since the 1800’s and its standards and approvals are recognised worldwide. The recognition is testimony to the extremely thorough technical evaluation work and rigorous quality audit process undertaken by the LPCB to ensure the security products it tests and approves deliver the proven levels of protection. The LPCB works closely with the government, police, insurers, risk consultants and architects to develop the standards and approval schemes which ensure security equipment and services deliver the levels of performance required to protect against criminal and terrorist threats. Approval to LPCB’s Loss Prevention Standards (LPSs) is specified across multiple sectors, including: education, finance, healthcare, manufacturing, the public sector, residential, retails and utilities. The standards are also specified for the protection of critical infrastructure where delivery of specified levels of security performance is critical. LPS 1175 LPS 1175 covers a broad scope of physical security products and services of any publicly available standard in the world. LPS 1175 has been developed over many years by the LPCB, Government, Insurers and Police, and has rapidly become a core element of physical security specification across many sectors. This standard consists of a number of security ratings with test requirements of ascending intensity. These are measured in terms of attack tools and time available to the attacker, and enables specifiers to select products according to the risks that they and their property face. LPS 1175 can be used in a range of applications, from residential to critical infrastructure projects. Security Rating SR8 SR7 SR6 SR5 SR4 SR3 SR2 SR1 Maximum Work Time (min) 20 10 10 10 10 5 3 1 Maximum Test Duration (min) 60 30 30 30 30 20 15 10 Domestic Typical Applications Commercial Government HIGH RISK LOW RISK SR8: Products certified to this standard provide 20 minutes of resistance to extreme means of forced entry into high value storage areas, with the use of a wide range of tools including mains powered tools. SR7: Products certified to this standard provide 10 minutes of resistance to professional means of forced entry into higher value storage areas, with the use of a wide range of tools including mains powered tools. SR6: Products certified to this standard provide 10 minutes of resistance to professional means of forced entry into higher value storage areas, with the use of a wide range of tools including mains powered tools. SR5: Products certified to this standard provide 10 minutes of resistance to experienced attempts at forced entry using a wide range of tools including battery powered tools. (E.g. SR4 tools plus circular saw and the 750W reciprocating saw with specialist blades.) SR4: Products certified to this standard provide 10 minutes of resistance to experienced attempts at forced entry using a wide range of tools including battery powered tools. (E.g. SR3 tools plus felling axe, sledgehammer, steel wedges, disc grinder, jigsaw, etc.) SR3: Products certified to this standard provide 5 minutes of resistance to experienced attempts at forced entry using a wide range of tools, using a range of techniques including those that involved the creation of noise. (E.g. SR2 tools plus short axe, chisels, crowbar gas torch, etc.) SR2: Products certified to this standard provide 3 minutes of resistance to a determined attack by an opportunist burglar using a range of techniques including those that involved the creation of noise. (E.g. SR1 tools plus bolt cutters, claw hammer, drill, etc.) SR1: Products certified to this standard provide the minimal level of security, 1 minute of resistance to opportunist attempts at entry, using a range of techniques including those that involve the creation of noise, as well as attacks involving breaking glass. (E.g. screwdriver, knife, pliers, etc.) Manufacturing Approval This installation guide for the Securiclad panel system has been designed to help and advise installation teams on the requirements to attain an approved system to LPS1175. There are clear and defined instructions along with diagrams which need to be followed during the build process, all associated ancillaries and fixings must also be supplied by Securiclad to ensure a completed system is approved under the LPCB Scope. Any variation from this scope will invalidate certification. In addition, apertures within the walling system or enclosure should only be filled with products that are approved for use on the Securiclad system and listed on LPCB Certificate 142c & 142d and www.redbooklive.com. Please contact Securiclad office for additional information required. Contact Details: Carl Lowson Manufacturing Manager Tel: 0191 2585052 Email: [email protected] Securiclad SR2, SR3 & SR4 Installation Guide This manual contains all construction details for Securiclad: The high security composite wall panel system, achieving LPS1175 SR2, SR3 and SR4 rating for internal and external applications. The details provided in this manual are applicable to a standard set-up. Should you require site specific installation, we can provide full technical assistance to support your requirements. Securiclad Fire Ratings: Manufactured to an ISO 9001:2008 quality assurance systems. Certificate Number 142. Fire rating explained:o The panels themselves are rated up to 4 hours as tested to LPS1208 and accessed to BS476 Part 22 – Certificate Number 142a. Fire Rated Enclosures up to 2 hours o This can be achieved by intumescent coating of all exposed hot rolled steel components such as corner posts, intermediated, ‘Goal-Post’ arrangements (Price on application) Fire Rated Enclosures from 2 up to 4 hours o This is a site specific action with all exposed steel work requiring protection using appropriate fire boards, the thickness of the board would depend on the required fire rating. Internal/External Vertical/Horizontal Panels 1. 2. 3. 4. 5. 6. 7. Ensure floor is level. The site is marked out using chalk line. Position and fix corner posts if applicable. Offer panel to channel and slide into position. Ensure panel is plumb before fixing. Repeat step 3 until wall is complete, then fix securely. Drill and fix channel 90° corner or abutments as step 2. See construction details/drawings for additional information. Horizontal panel construction requires 130mm long high tensile Dome Head Bolt and Temper Nut at max 600mm centres as detailed. Ceiling Ensure attack face of panel is on the external side of room. Fix and secure as construction detail Ceiling Support When installed Securiclad ceiling panels offer a limited walk-on facility, however this is suitable for intermittent personnel use only, and panels should not be used as a working platform. Overloading should be avoided at any time and personnel should not gather in groups greater than two on any single panel, particularly adjacent to apertures, which must be suitably framed and supported. Jumping and bouncing should be also avoided. In areas subject to frequent use and access areas, Youngman type boards and catwalks should be used as walkways. Ancillary equipment i.e. pipes, refrigeration equipment, ductwork, etc. should not be supported by the panels; the support should be taken from the building structure. Installation of equipment is not allowed on unprotected panels. The need for additional ceiling support for fire rated installations should be discussed with securiclad prior to installation. Note: Fire rated installations must be completed by using a bead of ‘Envirograph 62’ intumescent fire proof sealant applied to the female joint prior to the installation and sealed with a further dead on both faces. Note: Ceiling to ceiling panel joints are identical to the wall the wall panel flush joints. Maintenance Walls can be washed down with fresh water from a hose or bucket. A solution of fresh water and Tepol, or similar non aggressive detergent, which contains dilute ammonia, may be used to remove heavy deposits from walls, followed by a fresh water rinse. Water temperatures should not exceed 60°, with a maximum of 100lbs per square inch. Stubborn oil or grease stains can be easily removed with white spirit on a soft cloth, followed by an immediate fresh water rinse. Solvents, cleaners containing abrasives and cleaners in strong concentrations should not be used. Over-cleaning or scrubbing can be detrimental to the panel surface. To facilitate cleaning of panels, it is important that the installation of the panel system should prevent moisture collecting in crevices and joints. This is particularly important at the bottom of the wall panels, where pollutants from cleaning solutions of from floor soil can cause corrosion problems. This can be achieved by a design which ensures that the edges are folded back and by sealing the edges with a neutral curing silicone sealant. Health and Safety Ensure panels are lifted into place with the correct equipment as they weigh up to 70kg/m². The use of Cool Boy or Oktopus equipment is advisable for installation. 100mm 125mm 150mm SR2 Panel Wall 32 kg/m² 35 kg/m² 38 kg/m² SR3 Panel Wall 38 kg/m² 41 kg/m² 44 kg/m² SR4 Panel Wall 54 kg/m² 57 kg/m² 60 kg/m² SR3 Re-enforced Panel* Wall 54 kg/m² 57 kg/m² 60 kg/m² SR4 Re-enforced Panel* Wall 70 kg/m² 73 kg/m² 76 kg/m² SR2 Panel Ceiling 32 kg/m² 35 kg/m² 38 kg/m² SR3 Panel Ceiling 44 kg/m² 47 kg/m² 50 kg/m² SR4 Panel Ceiling 61 kg/m² 64 kg/m² 67 kg/m² *For use around Door area if Non Key/Key locking mechanism is used. Location of this panel type is to be no less than 1200mm radius from the locking mechanism. Under normal conditions the core within the security panel is stable and is not classified as carcinogenic. However, the core can be classed as an irritant and direct contact can cause an effect to the skin known as mechanical irritation. Gloves and general PPE should be worn. Cutting may cause dust which may also act as an irritant. General PPE should be worn. Materials used in manufacture are classed as non-hazardous. Structural For site specific questions and the latest information please refer to Securiclad directly. Walls Span details (all measurements in mm) – SR2 SR3 SR4 SR3 Re-enforcement Panel SR4 Re-enforcement Panel SR4 Double Skin Wall 2000 min to 5500 max 2000 min to 5500 max 2000 min to 5500 max 2000 min to 5500 max 2000 min to 5500 max 2000 min to 4500 max Ceilings Span details (all measurements in mm) – SR2 SR3 SR4 SR3 Re-enforcement Panel SR4 Re-enforcement Panel 2000 min to 5500 max 2000 min to 3000 max** 2000 min to 3000 max** 2000 min to 3000 max** 2000 min to 3000 max** ** Spans can be increased to 5500 with the inclusion of a top hat within the ceiling panel. When installed Securiclad ceiling panels offer a limited walk-on facility, however this is suitable for intermittent personnel use only, and panels should not be used as a working platform. Overloading should be avoided at any time and personnel should not gather in groups greater than two on any single panel, particularly adjacent to apertures which must be suitably framed and supported. Jumping and bouncing should be also avoided. In areas subject to frequent use and access areas, Youngman type boards and catwalks should be used as walkways. Ancillary equipment i.e. pipes, refrigeration equipment, ductwork, etc. should not be supported by the panels; the support should be taken from the building structure. Installation of equipment is not allowed on unprotected panels. Fixings Face fixing services e.g. air, surface mounted electrics, push pads, and security sensors can be fixed directly to the panel face. Heavier goods will need to be referred back to Securiclad to advise on project specific queries. Acoustic See data sheet from Rockwool. Material Specifications for the Manufacture of Securiclad Security Panels PIR – Polyisocyanurate Foam Mineral Wool – Rockwool Conrock 12 Siderise – 38mm Thick NXR Lamella Board Plywood – Redwood ply or OSB Galvanised Steel – G275 Hot Dipped Inner Skin – 0.5mm White Food Safe Laminate (WFSL) Outer Skin – 0.5mm WFSL or Plastisol Coated Steel Securiclad Panels: SR2 Securiclad SR2 is an alternative panel configuration to the standard Securiclad panel. The reduction of anticutting material to the SR2 level allows the panel to maintain the strength and durability and is designed for less critical security areas. E.g. Domestic risks 1 & 2 and Minor Commercial risks 2. Apertures within the walling system/enclosure should only be filled with products which are approved for use with the Securiclad System. Products that are approved for use on the Securiclad security panel system are listed on LPCB certification and www.redbooklive.com This SR2 option must be installed in accordance to the SR4 instructions using all the fixings and accessories as described within this manual with the expectations of door sets, refer to LPCB Certificate 142c & 142d. SR 3 & 4 Securiclad have introduced a number of product upgrades to create a range of panel options. They are all designed to enhance protection but each has a very unique attribute specific to environment and installation requirements. ‘Securiclad Core’ is an alternative panel configuration to the standard Securiclad panel. The SR3 and SR4 anticutting material is sandwiched between Mineral Wool/PIR, in the middle of the panel. This combination makes for a more aesthetically pleasing panel finish yet greater strength and durability of the panel. SECTION 2 PANEL DETAILS ATTACK FACE 0.5/0.7 STEEL SHEET PIR/MINERAL WOOL CORE 5 ANTI-CUTTING MATERIAL DIM 'X' 18 ENLARGED DETAIL SCALE 1:1 PIR/MINERAL WOOL CORE 0.5/0.7 STEEL SHEET SR2 PANEL JOINT DETAIL - WALL SCALE 1:1 SPS100/125/150 CONFIGURATION SPLINE SR2 WALL PANEL WIDTH (mm) HEIGHT/LENGTH (mm) THICKNESS (mm) (DIM 'X') MIN MAX MIN MAX SPS 100 SPS 125 SPS 150 250 1190* 2000 5500 100 125 150 * NOTE: ALL PANELS CAN BE PROVIDED IN EITHER 900mm OR 1190mm WIDE INCORPORATING MALE AND FEMALE JOINTS. PANEL WIDTH LESS THAN 900mm, DOWN TO A MINIMUM OF 250mm CAN BE PROVIDED BUT WILL ONLY INCORPORATE A MALE OR FEMALE JOINT WITH THE OPPOSITE BEING A STRAIGHT CUT. Securiclad SCALE 1:2 ATTACK FACE 0.5/0.7 STEEL SHEET DIM 'X' 5 ANTI-CUTTING MATERIAL PIR/MINERAL WOOL CORE 18 ENLARGED DETAIL SCALE 1:1 ANTI-CUTTING MATERIAL SR2 PANEL JOINT DETAIL - CEILING SCALE 1:1 0.5/0.7 STEEL SHEET SPS100/125/150 CONFIGURATION SPLINE SR2 CEILING PANEL WIDTH (mm) HEIGHT/LENGTH (mm) THICKNESS (mm) (DIM 'X') MIN MAX MIN MAX SPS 100 SPS 125 250 1190* 2000 5500 100 125 SPS 150 150 * NOTE: ALL PANELS CAN BE PROVIDED IN EITHER 900mm OR 1190mm WIDE INCORPORATING MALE AND FEMALE JOINTS. PANEL WIDTH LESS THAN 900mm, DOWN TO A MINIMUM OF 250mm CAN BE PROVIDED BUT WILL ONLY INCORPORATE A MALE OR FEMALE JOINT WITH THE OPPOSITE BEING A STRAIGHT CUT. Securiclad SCALE 1:2 ATTACK FACE 0.5/0.7 STEEL SHEET 5 PIR/MINERAL WOOL CORE DIM 'X' ANTI-CUTTING MATERIAL 18 ENLARGED DETAIL SCALE 1:1 PIR/MINERAL WOOL CORE 0.5/0.7 STEEL SHEET SR3 PANEL JOINT DETAIL - WALL SCALE 1:1 SPS100/125/150 SPLINE CONFIGURATION SR3 WALL PANEL WIDTH (mm) HEIGHT/LENGTH (mm) THICKNESS (mm)(DIM 'X') MIN MAX MIN MAX SPS 100 SPS 125 SPS 150 250 1190* 2000 5500 100 125 150 * NOTE: ALL PANELS CAN BE PROVIDED IN EITHER 900mm OR 1190mm WIDE INCORPORATING MALE AND FEMALE JOINTS. PANEL WIDTH LESS THAN 900mm, DOWN TO A MINIMUM OF 250mm CAN BE PROVIDED BUT WILL ONLY INCORPORATE A MALE OR FEMALE JOINT WITH THE OPPOSITE BEING A STRAIGHT CUT. Securiclad SCALE 1:2 0.5/0.7 STEEL SHEET ATTACK FACE 5 ANTI-CUTTING MATERIAL DIM 'X' PIR/MINERAL WOOL CORE 18 ENLARGED DETAIL SCALE 1:1 ANTI-CUTTING MATERIAL SR3 PANEL JOINT DETAIL - CEILING SCALE 1:1 0.5/0.7 STEEL SHEET SPS100/125/150 SPLINE CONFIGURATION SR3 CEILING PANEL WIDTH (mm) HEIGHT/LENGTH (mm) THICKNESS (mm) (DIM 'X') MIN MAX MIN MAX SPS 100 SPS 125 SPS 150 250 1190* 2000 3000 100 125 150 * NOTE: ALL PANELS CAN BE PROVIDED IN EITHER 900mm OR 1190mm WIDE INCORPORATING MALE AND FEMALE JOINTS. PANEL WIDTH LESS THAN 900mm, DOWN TO A MINIMUM OF 250mm CAN BE PROVIDED BUT WILL ONLY INCORPORATE A MALE OR FEMALE JOINT WITH THE OPPOSITE BEING A STRAIGHT CUT. Securiclad SCALE 1:2 ATTACK FACE 0.5/0.7 STEEL SHEET 5 PIR/MINERAL WOOL CORE DIM 'X' 18 ANTI-CUTTING MATERIAL ENLARGED DETAIL SCALE 1:1 PIR/MINERAL WOOL CORE 0.5/0.7 STEEL SHEET SR4 PANEL JOINT DETAIL - WALL SCALE 1:1 SPS100/125/150 CONFIGURATION SPLINE SR4 WALL PANEL WIDTH (mm) HEIGHT/LENGTH (mm) THICKNESS (mm) (DIM 'X') MIN MAX MIN MAX SPS 100 SPS 125 250 1190* 2000 5500 100 125 SPS 150 150 * NOTE: ALL PANELS CAN BE PROVIDED IN EITHER 900mm OR 1190mm WIDE INCORPORATING MALE AND FEMALE JOINTS. PANEL WIDTH LESS THAN 900mm, DOWN TO A MINIMUM OF 250mm CAN BE PROVIDED BUT WILL ONLY INCORPORATE A MALE OR FEMALE JOINT WITH THE OPPOSITE BEING A STRAIGHT CUT. SCALE 1:2 Securiclad ATTACK FACE 5 0.5/0.7 STEEL SHEET PIR/MINERAL WOOL CORE ANTI-CUTTING MATERIAL 18 DIM 'X' ANTI-CUTTING MATERIAL ENLARGED DETAIL SCALE 1:1 ANTI-CUTTING MATERIAL 0.5/0.7 STEEL SHEET SR4 PANEL JOINT DETAIL - CEILING SCALE 1:1 SPLINE SPS100/125/150 CONFIGURATION SR4 CEILING PANEL WIDTH (mm) HEIGHT/LENGTH (mm) THICKNESS (mm) (DIM 'X') MIN MAX MIN MAX SPS 100 SPS 125 SPS 150 250 1190* 2000 3000 100 125 150 * NOTE: ALL PANELS CAN BE PROVIDED IN EITHER 900mm OR 1190mm WIDE INCORPORATING MALE AND FEMALE JOINTS. PANEL WIDTH LESS THAN 900mm, DOWN TO A MINIMUM OF 250mm CAN BE PROVIDED BUT WILL ONLY INCORPORATE A MALE OR FEMALE JOINT WITH THE OPPOSITE BEING A STRAIGHT CUT. SCALE 1:2 Securiclad 0.5mm STEEL SHEET 38mm PIR/MINERAL WOOL 5 ANTI-CUTTING MATERIAL 0.5mm STEEL SHEET 18 0.5mm STEEL SHEET ENLARGED DETAIL SCALE 1:1 ANTI-CUTTING MATERIAL 38mm PIR/MINERAL WOOL 0.5mm STEEL SHEET SR4 DOUBLE SKIN DETAIL - WALL SCALE 1:1 250mm MIN STAGGER DPS50 CONFIGURATION SR4 WALL PANEL SR4 DOUBLE SKIN JOINT DETAIL - WALL SCALE 1:2 WIDTH (mm) HEIGHT/LENGTH (mm) OVERALL WALL THICKNESS (mm) MIN MAX MIN MAX DPS 50 250 1190* 2000 4500 100 Securiclad 0.5mm STEEL SHEET 38mm PIR/MINERAL WOOL 5 ANTI-CUTTING MATERIAL 0.5mm STEEL SHEET 18 0.5mm STEEL SHEET ENLARGED DETAIL SCALE 1:1 ANTI-CUTTING MATERIAL 38mm PIR/MINERAL WOOL 0.5mm STEEL SHEET SR4 DOUBLE SKIN DETAIL - CEILING SCALE 1:1 250 mm MIN STAGGER DPS50 CONFIGURATION SR4 CEILING PANEL SR4 DOUBLE SKIN JOINT DETAIL - CEILING SCALE 1:2 WIDTH (mm) HEIGHT/LENGTH (mm) OVERALL WALL THICKNESS (mm) MIN MAX MIN MAX DPS 50 250 1190* 2000 3000 100 Securiclad SPLINE MINERAL WOOL 76 (SPS 100), 101 (SPS 125) OR 126 (SPS 150) ATTACK FACE 25 ANTI-CUTTING MATERIAL MECHANICAL FIXING 5.5x16mm SELF DRILL/TAP @ 600mm CENTRES OUTER STEEL FACE BONDED 2 THK GALV MECHANICAL FIXING 4.8x19mm PRO LOW PROFILE PAN HEAD SELF DRILLING SCREW @ 600mm CENTRES SPLINE MINERAL WOOL BONDED ANTI-CUTTING MATERIAL FILL WITH MINERAL WOOL 70x70mm FIRE-STOP 12 74 INNER STEEL FACE SR3 CEILING SPAN 3000-5500mm Securiclad CONFIGURATION SR3 CEILING PANEL WIDTH (mm) MIN 250 SPS100/125/150 WITH TOP HAT HEIGHT/LENGTH (mm) MAX 1190* MIN 3000 MAX 5500 THICKNESS (mm) (DIM 'X') SPS 100 100 SPS 125 125 SPS 150 150 * NOTE: ALL PANELS CAN BE PROVIDED IN EITHER 900mm OR 1190mm WIDE INCORPORATING MALE AND FEMALE JOINTS. PANEL WIDTH LESS THAN 900mm, DOWN TO A MINIMUM OF 250mm CAN BE PROVIDED BUT WILL ONLY INCORPORATE A MALE OR FEMALE JOINT WITH THE OPPOSITE BEING A STRAIGHT CUT. ANTI-CUTTING MATERIAL DIM 'X' ATTACK FACE ANTI-CUTTING MATERIAL SR4 CEILING SPAN 3000-5500mm Securiclad Reinforcement Panel Configuration SR3 & SR4 The Securiclad SR3/SR4 Reinforcement Panel is specifically designed for use when a non-key/key door mechanism is chosen within the system. The additional anti cutting material layers are specific arranged to significantly increase the panel’s security around the door sets within a 1200mm radius. Note: The Reinforcement Panel must be installed in accordance to the SR4 installation Guide using all fixings and accessories as describes within the installation guidance using all the fixings and accessories as described within the manual with the exceptions of the door sets. Refer to LPCB Certificate 142c & 142d. ATTACK FACE 0.5/0.7 STEEL SHEET PIR/MINERAL WOOL CORE 5 ANTI-CUTTING MATERIAL DIM 'X' 18 ENLARGED DETAIL SCALE 1:1 PIR/MINERAL WOOL CORE 0.5/0.7 STEEL SHEET SR3 RE-ENFORCEMENT PANEL JOINT DETAIL - WALL SCALE 1:1 SPSCORE 100/125/150 SPLINE CONFIGURATION SR3 RE-ENF PANEL WIDTH (mm) HEIGHT/LENGTH (mm) MIN MAX MIN 250 1190* 2000 MAX 5500 THICKNESS (mm) (DIM 'X') SPS 100 SPS 125 SPS 150 100 125 150 * NOTE: ALL PANELS CAN BE PROVIDED IN EITHER 900mm OR 1190mm WIDE INCORPORATING MALE AND FEMALE JOINTS. PANEL WIDTH LESS THAN 900mm, DOWN TO A MINIMUM OF 250mm CAN BE PROVIDED BUT WILL ONLY INCORPORATE A MALE OR FEMALE JOINT WITH THE OPPOSITE BEING A STRAIGHT CUT. SCALE 1:2 Securiclad ATTACK FACE 5 0.5/0.7 STEEL SHEET ANTI-CUTTING MATERIAL 18 DIM 'X' ENLARGED DETAIL SCALE 1:1 PIR/MINERAL WOOL CORE ANTI-CUTTING MATERIAL 0.5/0.7 STEEL SHEET SR3 RE-ENFORCEMENT PANEL JOINT DETAIL - CEILING SCALE 1:1 SPS 100/125/150 SPLINE CONFIGURATION SR3 RE-ENFORCED CEILING PANEL WIDTH (mm) HEIGHT/LENGTH (mm) THICKNESS (mm) (DIM 'X') MIN MAX MIN MAX SPS 100 SPS 125 SPS 150 250 1190* 2000 5500 100 125 150 * NOTE: ALL PANELS CAN BE PROVIDED IN EITHER 900mm OR 1190mm WIDE INCORPORATING MALE AND FEMALE JOINTS. PANEL WIDTH LESS THAN 900mm, DOWN TO A MINIMUM OF 250mm CAN BE PROVIDED BUT WILL ONLY INCORPORATE A MALE OR FEMALE JOINT WITH THE OPPOSITE BEING A STRAIGHT CUT. SCALE 1:2 Securiclad ATTACK FACE 0.5/0.7 STEEL SHEET PIR/MINERAL WOOL CORE DIM 'X' 5 ANTI-CUTTING MATERIAL 18 ENLARGED DETAIL SCALE 1:1 PIR/MINERAL WOOL CORE 0.5/0.7 STEEL SHEET SR4 RE-ENFORCEMENT PANEL JOINT DETAIL - WALL SCALE 1:1 SPSCORE 100/125/150 SPLINE CONFIGURATION SR4 RE-ENF PANEL WIDTH (mm) HEIGHT/LENGTH (mm) MIN MAX MIN 250 1190* 2000 MAX 5500 THICKNESS (mm) (DIM 'X') SPS 100 SPS 125 SPS 150 100 125 150 * NOTE: ALL PANELS CAN BE PROVIDED IN EITHER 900mm OR 1190mm WIDE INCORPORATING MALE AND FEMALE JOINTS. PANEL WIDTH LESS THAN 900mm, DOWN TO A MINIMUM OF 250mm CAN BE PROVIDED BUT WILL ONLY INCORPORATE A MALE OR FEMALE JOINT WITH THE OPPOSITE BEING A STRAIGHT CUT. SCALE 1:2 Securiclad ATTACK FACE ANTI-CUTTING MATERIAL DIM 'X' 5 0.5/0.7 STEEL SHEET PIR/MINERAL WOOL CORE 18 ENLARGED DETAIL SCALE 1:1 ANTI-CUTTING MATERIAL 0.5/0.7 STEEL SHEET SR4 RE-ENFORCEMENT PANEL JOINT DETAIL - CEILING SCALE 1:1 SPS 100/125/150 SPLINE CONFIGURATION SR4 RE-ENFORCED CEILING PANEL WIDTH (mm) HEIGHT/LENGTH (mm) THICKNESS (mm) (DIM 'X') MIN MAX MIN MAX SPS 100 SPS 125 SPS 150 250 1190* 2000 5500 100 125 150 * NOTE: ALL PANELS CAN BE PROVIDED IN EITHER 900mm OR 1190mm WIDE INCORPORATING MALE AND FEMALE JOINTS. PANEL WIDTH LESS THAN 900mm, DOWN TO A MINIMUM OF 250mm CAN BE PROVIDED BUT WILL ONLY INCORPORATE A MALE OR FEMALE JOINT WITH THE OPPOSITE BEING A STRAIGHT CUT. SCALE 1:2 Securiclad DIM 'X' ANTI-CUTTING MATERIAL ANTI-CUTTING MATERIAL Securiclad CONFIGURATION SR3 CEILING PANEL WIDTH (mm) MIN 250 SPS100/125/150 WITH TOP HAT HEIGHT/LENGTH (mm) MAX 1190* MIN 3000 MAX 5500 THICKNESS (mm) (DIM 'X') SPS 100 100 SPS 125 125 SPS 150 150 * NOTE: ALL PANELS CAN BE PROVIDED IN EITHER 900mm OR 1190mm WIDE INCORPORATING MALE AND FEMALE JOINTS. PANEL WIDTH LESS THAN 900mm, DOWN TO A MINIMUM OF 250mm CAN BE PROVIDED BUT WILL ONLY INCORPORATE A MALE OR FEMALE JOINT WITH THE OPPOSITE BEING A STRAIGHT CUT. ANTI-CUTTING MATERIAL DIM 'X' ATTACK FACE ANTI-CUTTING MATERIAL Securiclad SECTION 3 WALL DETAILS FULL PANEL F16 AT 600mm CENTRES MAX. STAGGERED NOTE: GALVANISED STEEL ANGLES SUPPLIED IN MAX 3000mm LENGTHS AND SHOULD BE CUT TO SUIT INSTALLATION HEIGHT. WHEN WALL IS GREATER THAN 3000mm CUT STEEL ANGLES TO MATCH HEIGHT OF WALL. MINIMUM ANGLE LENGTH TO BE 1000mm & INCLUDE A MINIMUM OF 2 No. FIXINGS FULL PANEL A10 FULL PANELS INTO CORNER POSTS TO BE FIXED USING F16 TAMPER FIXINGS . Securiclad FULL PANEL INTO CORNER POST NARROW PANEL F12 AT 600mm CENTRES MAX. STAGGERED NARROW PANELS INTO CORNER POSTS TO BE FIXED USING F12 BOLTED FIXINGS. ATTACK FACE NOTE: GALVANISED STEEL ANGLES SUPPLIED IN MAX 3000mm LENGTHS AND SHOULD BE CUT TO SUIT INSTALLATION HEIGHT. WHEN WALL IS GREATER THAN 3000mm CUT STEEL ANGLES TO MATCH HEIGHT OF WALL. MINIMUM ANGLE LENGTH TO BE 1000mm & INCLUDE A MINIMUM OF 2 No. FIXINGS NARROW PANEL A10 Securiclad NARROW PANEL INTO CORNER POST F14 FIXINGS AT 600mm MAX CENTRES INTO EXISTING CEILING EXISTING CEILING A12 F16 FIXINGS AT 600mm MAX CENTRES F15 FIXING TO EXISTING WALL A10 WALL PANEL EXISTING WALL. CONCRETE OR BRICK/BLOCKWORK ATTACK FACE A12 EXISTING WALL. CONCRETE OR BRICK/BLOCKWORK F16 FIXINGS AT 600mm MAX CENTRES A10 Securiclad F15 FIXINGS AT 600mm MAX CENTRES INTO EXISTING FLOOR PARTITION WALL - BASE ANGLES A12 F16 FIXINGS AT 600mm MAX CENTRES A10 WALL PANEL EXISTING WALL. PLYWOOD OR SOFTWALL ATTACK FACE EXISTING WALL. PLYWOOD OR SOFTWALL F16 FIXINGS AT 600mm MAX CENTRES C10 Securiclad F15 FIXINGS AT 600mm MAX CENTRES INTO EXISTING FLOOR PARTITION WALL - BASE CHANNEL EXISTING CEILING P1 ATTACK FACE A12 F16 FIXINGS AT 600mm MAX CENTRES F16 FIXINGS AT 600mm MAX CENTRES A10 SECTION 'A-A' FULL PANELS INTO CORNER POST Securiclad EXISTING CEILING A12 NARROW PANELS INTO CORNER POSTS TO BE FIXED USING F12 BOLTED FIXINGS. NARROW PANEL ATTACK FACE A10 NARROW PANEL A10 F12 AT 600mm CENTRES MAX. STAGGERED SECTION 'A-A' NARROW PANELS INTO CORNER POST Securiclad SECTION 4 CEILING DETAILS A11 A10 NOTE: GALVANISED STEEL ANGLES SUPPLIED IN MAX 3000mm LENGTHS AND SHOULD BE CUT TO SUIT INSTALLATION HEIGHT. WHEN WALL IS GREATER THAN 3000mm CUT STEEL ANGLES TO MATCH HEIGHT OF WALL. MINIMUM ANGLE LENGTH TO BE 1000mm & INCLUDE A MINIMUM OF 2 No. FIXINGS Securiclad WALL TO CEILING DETAIL ATTACK FACE CEILING PANEL SR CORE A10 A10 P2 (OPTIONAL) WALL PANEL P2 (OPTIONAL) Securiclad ATTACK FACE CEILING PANEL SR CORE A10 P2 (OPTIONAL) WALL PANEL SR CORE P2 (OPTIONAL) A10 Securiclad 0.5mm THICK STEEL DECORATIVE FLASHING STEELWORK (I BEAM) BY OTHERS 2mm GALVANIZED COVER STRIP NOTE: A MINIMUM OF THREE FIXINGS MUST USED Securiclad SECTION 5 FLOOR DETAILS WALL PANEL ATTACK FACE F16 FIXINGS AT 600mm MAX CENTRES C10 Securiclad F15 FIXINGS AT 600mm MAX CENTRES INTO EXISTING FLOOR SECURICLAD WALL/FLOOR FIXING ATTACK FACE C10 (WPC) F15 FIXINGS AT 600mm MAX CENTRES Securiclad RAISED BASE DETAIL WITH DRIP THERMAL BREAK ATTACK FACE WALL PANEL FLASHING FIXED WITH STRUCTURAL BONDING TAPE (NOT SHOWN) OR MECHANICALLY FIXEDLE INTERNAL CONCRETE FLOOR FINISH FLOOR INSULATION C10 (WPC) COVER CLOSER FLASHING (OPTIONAL) COLOUR TO MATCH PANEL F12 FIXINGS AT 600mm MAX CENTRES DAMP PROOF MEMBRANE(DPM) F15 FIXINGS AT 600mm MAX CENTRES Securiclad BASE FIXING DETAIL WALL PANEL C10 Securiclad F15 FIXINGS AT 600mm MAX CENTRES INTO EXISTING FLOOR SECTION JOINTS 6 MIN 250mm NOTE: GALVANISED STEEL ANGLES SUPPLIED IN MAX 3000mm LENGTHS AND SHOULD BE CUT TO SUIT INSTALLATION. WHEN WALL IS GREATER THAN 3000mm CUT STEEL ANGLES TO MATCH LENGTH OF WALL A MINIMUM OF THREE F12 BLOTS MUST BE USED IN HEADER U CHANNEL MAX 600mm CENTRES NOTE: WHEN PANELS SPAN HORIZONTALLY THE TOP-MOST PANEL MUST BE A MINIMUM OF 250 WIDE. ANY PANEL LESS THAN FULL WIDTH MUST HAVE A MINIMUM OF 3 No. F12 BOLTS IN THE JOINT BETWEEN IT AND THE ADJACENT PANEL. ATTACK FACE Securiclad HORIZONTAL WALL JOINT NOTE: WHEN FIXING TO BRICKWORK OR CONCRETE USE F15, MAX 600mm CENTRES VIA 13mm DIAMETER HOLES. WHEN FIXING TO STEELWORK USE F11, MAX 600mm CENTRES. Securiclad NOTE: WHEN FIXING TO BRICKWORK OR CONCRETE USE F15, MAX 600mm CENTRES VIA 13mm DIAMETER HOLES. WHEN FIXING TO STEELWORK USE F11, MAX 600mm CENTRES. Securiclad F11 FIXINGS AT 600mm MAX CENTRES F11 FIXINGS AT 600mm MAX CENTRES F16 FIXINGS AT 600mm MAX CENTRES C10 A10 PANEL PANEL Securiclad 'A' EXTERNAL ANGLE 250 mm MINIMUM NOTE: WHERE A DOOR HEADER PANEL IS REQUIRED A MINIMUM OF 3 No. F12 BOLTED FIXINGS MUST BE USED AT THE TOP AND BOTTOM OF THE HEADER PANEL HEADER PANEL HEADER PANEL MUST BE A MINIMUM OF 250mm IN LENGTH ATTACK FACE 'A' PANEL 180x180 EXTERNAL ANGLE DOOR CEILING PANEL PANEL WALL PANEL 250mm MINIMUM 70x70 INTERNAL ANGLE C11/C13 DOOR CHANNEL TOP OF DOOR FRAME F12 FIXING. 3 No. MIN ATTACK FACE F12 FIXING. 3 No. MIN SECTION 'A-A' VERTICAL WALL JOINT WITH HEADER PANEL Securiclad PANEL PANEL PANEL 250 MIN NOTE: MINIMUM OF 3 No. F12 BOLTED FIXINGS MUST BE USED 'A' 180x180 EXTERNAL ANGLE ATTACK FACE 'A' CEILING PANEL DOOR WALL PANEL 250mm MINIMUM 70x70 INTERNAL ANGLE C11/C13 DOOR CHANNEL TOP OF DOOR FRAME F12 FIXING. 3 No. MIN SECTION 'A-A' ATTACK FACE WHERE A PANEL IS CUT TO ACCOMODATE A DOOR FRAME A MINIMUM OF 250mm MUST REMAIN 250 MIN 250 MIN VERTICAL WALL JOINT - NO HEADER PANEL Securiclad SECTION 7 PENETRATIONS Aperture Construction and Approved Products Apertures within the walling and ceiling system or enclosure should only be filled with products that are approved for use on the Securiclad system and listed on LPCB Certificate 142c & 142d and www.redbooklive.com. PENETRATION CANNOT BE LESS THAN 150mm FROM THE TOP/BOTTOM OR SIDE OF THE PANEL AND NOT LESS THAN 75mm FROM ANOTHER PENETRATION IN ANY DIRECTION FOR SR2 & SR3 ONLY, FOR SR4 DIMENSIONS ARE 250mm & 150mm RESPECTIVELY. ) R3 MIN 30mm ELEVATION ON PANEL SCALE 1:7.5 PANEL COLLAR ZmmØ 150 MIN mØ Xm 150 MIN N MI 5 No. EQUALLY SPACED 17 Ø BOLT HOLES ON 130mm PCD YmmØ 75 TO MIN 30mm SR N( IO AT TR R4 E PEN R S ER m FO H OT m AN 150 S 2& COLLAR Ymm Ø FRONT ELEVATION SCALE 1:2 6 SECTION THROUGH SCALE 1:2 MATERIAL: ZmmØ MILD STEEL TUBE x 3mm (POWDER COATED TO SUIT) YmmØ X 6mm THICK PLATE WITH XmmØ HOLE NUMBER REQUIRED PER INSTALLATIOn: 2No (ONE EACH SIDE OF THE PANEL) FIXINGS: 5 No. F12 FIXINGS SECTION THROUGH PANEL SCALE 1:5 Securiclad 200 20 2 300 SIDE ELEVATION SCALE 1:2 FRONT ELEVATION SCALE 1:2 MATERIAL: 300mm x 200mm x 2mm THICK GALV PLATE (POWDER COATS TO SUIT) NUMBER REQUIRED PER INSTALLATION: 2No ( ONE EACH SIDE OF PANEL) FIXINGS: 4 No. F12 FIXINGS 150 mm MIN (SR4) 40 20 90 75mm MIN (SR2 & SR3) 55 110 200 55 250mm MIN (SR4) SECURICLAD PANEL 8 No. 50mm Ø HOLES 150mm MIN (SR2 & SR3) 4 No. 15.5mm Ø HOLES 150mm MIN (SR2 & SR3) 250mm MIN (SR4) ELEVATION ON PANEL SCALE 1:10 Securiclad NOTE: PENETRATION 'A' CANNOT BE LESS THAN 150mm FROM THE TOP/BOTTOM OR SIDE OF THE PANEL AND NOT LESS THAN 75mm FROM ANOTHER PENETRATION IN ANY DIRECTION FOR SR2 & SR3 ONLY, FOR SR4 DIMENSIONS ARE 250mm & 150mm RESPECTIVELY. PART 'A' = 4.5mm Ø HOLE (TYP) PART 'B' 100 100 PART 'B' 200 (PART 'B') 200 50 = 52 PART 'A' PART 'B' 3 = = 'TYPICAL POSITIONS' PART 'A' 198.5 (PART 'A') FRONT ELEVATION SCALE 1:2 PANEL PENETRATION MATERIAL: 50mm x 49mm x 3mm THICK GALV ANGLE (POWDER COATS TO SUIT) NUMBER REQUIRED PER INSTALLATION: 2No SETS ( 2No REQUIRED PARTS 'A' AND 'B' EACH SIDE OF PANEL) FIXINGS: 12 No. F11 FIXINGS Securiclad PENETRATION SECTION THROUGH PANEL SCALE 1:5 75 Ø TO 20 20 250 MIN (FOR (SR4) 75 Ø ES SØ LE HO 150mm MIN TO 150 MIN Ø TO L HO ANOTHER PENETRATION (SR4) 75mm MIN TO ANOTHER PENETRATION (SR2 & SR3) (FOR SR2 & SR3) HO HO LE LE SØ SØ 20 20 TO TO 75 75 Ø Ø NOTE: HOLE EDGE DISTANCE CANNOT BE LESS THAN 150mm FROM THE TOP/BOTTOM OR SIDE OF THE PANEL AND NOT LESS THAN 75mm FROM ANOTHER PENETRATION IN ANY DIRECTION FOR SR3 & SR4, FOR SR4 DIMENSIONS ARE 250mm & 150mm RESPECTIVELY. Securiclad SECURICLAD PANEL UNPROTECTED PENETRATIONS C11 60mm X 102mm X 60 X 6mm THICK HOT ROLLED STEEL U CHANNEL ON THREE SIDES FOR DOORS AND FOUR SIDES FOR WINDOWS, SECURITY GRILLS ETC OF THE APERTURE CORNERS TO BE MITRED. F12 FIXINGS AT MAX 600mm CENTRES C13 NOTE: A MINIMUM OF THREE FIXINGS MUST BE ON EACH SIDE OF THE FRAME SECTION Securiclad FRAME-OUT CHANNEL OPTIONS SECTION 8 ASSOCIATED SECURICLAD COMPONENTS 70 2mm MINIMUM GALV STEEL 70 70 3 THK 103 (INT) 2 THK A10 C10 2mm MINIMUM GALV STEEL 180 2mm MINIMUM GALV STEEL 60 180 6 THK 103 (INT) 2 THK C11 A11 100 6 THK 70 70 6 THK 103 (INT) 2 THK A12 C13 Securiclad X Y Y Y Y Y X 70 22 CUSTOMER LENGTHS DIM X DIM Y DIM Z Z C13 CHANNEL -SIDE VIEW SCALE 1:10 X Y Y Y Y Y X Y Y Y Y X 103 INT 17 Ø HOLES 14 Ø HOLES X Y C13 CHANNEL -PLAN VIEW SCALE 1:10 35 6 100 (100) 6 6 14mm Ø HOLE 6 17mm Ø HOLE 48 22 EXTERNAL FACE 6 103 121 64 70 TYPICAL SECTION THROUGH C13 CHANNEL 6 THICK HOT ROLLED STEEL SCALE 1:2 Securiclad X Y Y Y Y Y X 60 25 CUSTOMER LENGTHS DIM X DIM Y DIM Z Z C11 CHANNEL -SIDE VIEW SCALE 1:10 X Y Y Y Y Y X Y Y Y X 103 INT 14 Ø HOLES 17 Ø HOLES X Y Y C11 CHANNEL -PLAN VIEW SCALE 1:10 103 14mm Ø HOLE 6 60 17mm Ø HOLE Securiclad TYPICAL SECTION THROUGH C11 CHANNEL 6 THICK HOT ROLLED STEEL SCALE 1:2 X Y Y Y Y Y X CUSTOMER LENGTHS DIM X DIM Y DIM Z 70 25 6 Ø HOLES Z C10 CHANNEL -SIDE VIEW SCALE 1:10 X Y Y Y Y Y X W W 14 Ø HOLES C10 CHANNEL -PLAN VIEW SCALE 1:10 70 3 THK 70 103 TYPICAL SECTION THROUGH C11 CHANNEL 3 THICK GALV STEEL SCALE 1:2 Securiclad CUSTOMER LENGTHS DIM Z 70 Z A12 ANGLE SCALE 1:10 70 100 2 THK TYPICAL SECTION THROUGH A12 ANGLE 2 THICK GALV STEEL SCALE 1:2 Securiclad Z CUSTOMER LENGTHS DIM X DIM Y DIM Z 16 Ø HOLES 50 Y Y Y Y Y 50 A11 ANGLE - SIDE VIEW SCALE 1:10 16 Ø HOLES 75 Y Y Y Y X 75 A11 ANGLE - PLAN VIEW SCALE 1:10 Z 50 Y Y Y Y Y 50 125 ℄ 16 Ø HOLES 75 Y Y Y DEVELOPED VIEW - MANUFACTURING ONLY 180 SCALE 1:10 180 363 125 16 Ø HOLES TYPICAL SECTION THROUGH A11 ANGLE 2 THICK GALV STEEL SCALE 1:5 2 THK Y X 75 Securiclad CUSTOMER LENGTHS DIM Z 70 Z A10 ANGLE SCALE 1:10 70 70 2 THK TYPICAL SECTION THROUGH A10 ANGLE 2 THICK GALV STEEL SCALE 1:2 Securiclad 6 PLT 167x6 THK PLATE DIM 'F' 6 Ø HOLES FOR F16 FIXINGS 167x6 THK PLATE WELDED TO RHS ATTACK FACE 50 DIM 'D' 50 167 DIM 'G' 167 A 26 Ø HOLES 100 (100) 100 26 26 50 DIM 'B' DIM 'B' 6 DIM 'B' 13 Ø HOLES FOR F15 FIXINGS DIM 'B' DIM 'B' 28 14 Ø HOLES FOR F15 FIXINGS 36 26 6 DRILL & TAP HOLE FOR M8 (MINIMUM) BOLT CUSTOMER DIMS DIM A DIM B DIM C DIM D DIM E DIM F DIM G 100x167x10 THK BASE PLATE 50 6 THK DIM 'B' DIM 'B' DIM 'B' ATTACK FACE F16 WALL F15 DIM 'B' DIM 'B' 75 40 10 THK DIMS IN RHS SECTION 'A-A' 28 167x 6 THK LOOSE PLATE 50 50 END POST - TAMPER OPTION 50 167 B A 6 Ø HOLES FOR F16 FIXINGS CLEARANCE HOLE TO SUIT BOLT SIZE THROUGH RHS DIM 'B' DIM 'E' (LENGTH OF 167x6 THICK PLATE - FULL HEIGHT IF NO CEILING REQUIRED) SECTION 'B-B' M8 BOLT (MIN) DIM 'B' DIM 'B' 13 Ø HOLES N/S FACE 26 Ø HOLES OPP FACE DIMS IN PLT 100x100 x6 RHS DIM 'B' DIM 'B' 50 50 HOLES FOR M8 (MIN) BOLTS DRILLED AND TAPPED THIS FACE 40 DIMS IN RHS DIM 'B' DIM 'B' DIM 'B' 6 Ø HOLES IN PLATE DIM 'B' DIM 'B' DIM 'C' (LENGTH OF 100x100x6 RHS - FULL HEIGHT IF NO CEILING REQUIRED) 50 50 B 10 THK DIM 'A' (LENGTH OF 234x6 THICK PLATE) 167 CLEARANCE HOLES TO SUIT BOLT SIZE THROUGH RHS 50 LOOSE PLATE 28 LOOSE PLATE PLAN VIEW F16 Securiclad 6 PLT 167x6 THK PLATE DIM 'F' 14 Ø HOLES FOR F12 FIXINGS 167x6 THK PLATE WELDED TO RHS ATTACK FACE 50 DIM 'D' 50 167 DIM 'G' 167 A 26 Ø HOLES 100 26 26 50 DIM 'B' 100 (100) DIM 'B' DIM 'B' 6 13 Ø HOLES FOR F15 FIXINGS DIM 'B' DIM 'B' 28 14 Ø HOLES FOR F15 FIXINGS 36 26 6 DRILL & TAP HOLE FOR M8 (MINIMUM) BOLT CUSTOMER DIMS DIM A DIM B DIM C DIM D DIM E DIM F DIM G 100x167x10 THK BASE PLATE 50 6 THK DIM 'B' DIM 'B' DIM 'B' ATTACK FACE WALL F15 DIM 'B' DIM 'B' CLEARANCE HOLES TO SUIT BOLT SIZE THROUGH RHS 50 40 10 THK DIMS IN RHS SECTION 'A-A' 28 167 50 50 END POST - BOLTED OPTION 50 167x 6 THK LOOSE PLATE B A 14 Ø HOLES FOR F12 FIXINGS CLEARANCE HOLE TO SUIT BOLT SIZE THROUGH RHS DIM 'B' DIM 'E' (LENGTH OF 167x6 THICK PLATE - FULL HEIGHT IF NO CEILING REQUIRED) DIM 'B' SECTION 'B-B' M8 BOLT (MIN) DIM 'B' DIM 'B' 13 Ø HOLES N/S FACE 26 Ø HOLES OPP FACE DIMS IN PLT 100x100 x6 RHS DIM 'B' DIM 'B' 50 50 HOLES FOR M8 (MIN) BOLTS DRILLED AND TAPPED THIS FACE 40 DIMS IN RHS DIM 'B' DIM 'B' 17 Ø HOLES IN PLATE FOR F12 FIXINGS DIM 'B' DIM 'B' DIM 'C' (LENGTH OF 100x100x6 RHS - FULL HEIGHT IF NO CEILING REQUIRED) 50 50 B 10 THK DIM 'A' (LENGTH OF 234x6 THICK PLATE) 167 50 LOOSE PLATE 28 LOOSE PLATE PLAN VIEW F12 Securiclad DIM 'G' DIM 'F' ATTACK FACE 234x6 THK PLATE WELDED TO RHS 36 50 DIM 'D' 50 28 28 36 6 28 100 (100) 48 234 6 THK DIM 'B' DIM 'B' 6 Ø HOLES FOR F16 FIXINGS 28 117 234 DIM 'B' DIM 'B' 234x 6 THK LOOSE PLATE DIM 'B' DIM 'B' 75 40 10 THK DIMS IN RHS SECTION 'A-A' 100x234x10 THK BASE PLATE 28 50 50 DIMS IN PLT INLINE POST - TAMPER OPTION 26 6 50 CLEARANCE HOLE TO SUIT BOLT SIZE THROUGH RHS 6 Ø HOLES FOR F16 FIXINGS B A 26 CUSTOMER DIMS DIM A DIM B DIM C DIM D DIM E DIM F DIM G SECTION 'B-B' F16 F16 13 Ø HOLES N/S FACE 26 Ø HOLES OPP FACE DIM 'B' DIM 'B' HOLES FOR M8 (MIN) BOLTS DRILLED AND TAPPED THIS FACE DIM 'B' DIM 'B' 50 50 DIM 'E' (LENGTH OF 234x6 THICK PLATE - FULL HEIGHT IF NO CEILING REQUIRED) 6 Ø HOLES IN PLATE 40 DIMS IN RHS DIM 'B' DIM 'B' DIM 'B' 50 50 DIM 'B' DIM 'C' (LENGTH OF 100x100x6 RHS - FULL HEIGHT IF NO CEILING REQUIRED) DIM 'B' 100x100 x6 RHS B 10 THK DIM 'A' (LENGTH OF 234x6 THICK PLATE) DRILL & TAP HOLE FOR M8 (MINIMUM) BOLT 6 Ø HOLES IN PLATE 4 No. 14 Ø HOLES FOR F15 FIXINGS 26 48 26 DIM 'B' DIM 'B' 6 DIM 'B' DIM 'B' DIM 'B' 26 28 6 Ø HOLES FOR F16 FIXINGS 100 234 6 PLT 26 234 A 234x6 THK PLATE CLEARANCE HOLES TO SUIT BOLT SIZE THROUGH RHS 117 LOOSE PLATE ATTACK FACE M8 BOLT (MIN) PLAN VIEW F16 LOOSE PLATE F16 Securiclad 234 6 PLT DIM 'G' DIM 'F' ATTACK FACE 234x6 THK PLATE WELDED TO RHS 36 50 DIM 'D' 50 14 Ø HOLES FOR F12 FIXINGS 36 28 48 26 26 DIM 'B' 100 (100) DIM 'B' DIM 'B' 6 DIM 'B' DIM 'B' 48 28 26 28 26 6 28 234 6 THK DIM 'B' DIM 'B' 14 Ø HOLES FOR F12 FIXINGS 28 117 234 234x 6 THK LOOSE PLATE ATTACK FACE DIM 'B' DIM 'B' DIM 'B' CLEARANCE HOLES TO SUIT BOLT SIZE THROUGH RHS 50 50 40 10 THK DIMS IN RHS SECTION 'A-A' 100x234x10 THK BASE PLATE 28 DIM 'B' DIM 'E' (LENGTH OF 234x6 THICK PLATE - FULL HEIGHT IF NO CEILING REQUIRED) DIM 'B' DIM 'B' DIM 'B' 50 INLINE POST - BOLTED OPTION 26 6 50 CLEARANCE HOLE TO SUIT BOLT SIZE THROUGH RHS 14 Ø HOLES FOR F12 FIXINGS B A 26 CUSTOMER DIMS DIM A DIM B DIM C DIM D DIM E DIM F DIM G SECTION 'B-B' F12 13 Ø HOLES N/S FACE 26 Ø HOLES OPP FACE DIMS IN PLT DIM 'B' DIM 'B' DIM 'B' HOLES FOR M8 (MIN) BOLTS DRILLED AND TAPPED THIS FACE 40 DIMS IN RHS 50 50 DIM 'B' 50 50 17 Ø HOLES IN PLATE FOR F12 FIXINGS DIM 'B' DIM 'C' (LENGTH OF 100x100x6 RHS - FULL HEIGHT IF NO CEILING REQUIRED) DIM 'B' 100x100 x6 RHS B 10 THK DIM 'A' (LENGTH OF 234x6 THICK PLATE) DRILL & TAP HOLE FOR M8 (MINIMUM) BOLT 17 Ø HOLES IN PLATE FOR F12 FIXINGS 4 No. 14 Ø HOLES FOR F15 FIXINGS 100 234 A 234x6 THK PLATE 117 LOOSE PLATE M8 BOLT (MIN) PLAN VIEW LOOSE PLATE F12 Securiclad 14 Ø HOLES FOR F12 FIXINGS 167 100 (100) 6 6 ATTACK FACE DIM 'F' 28 100x100x6 RHS 'TOP' CUSTOMER DIMS DIM A DIM B DIM C DIM D DIM E DIM F DIM G DIM H DIM J DIM K DIM L 17 Ø HOLES FOR F12 FIXINGS 6 167 100 (100) 28 DIM 'L' 17 Ø HOLES FOR F12 FIXINGS DIM 'J' DIM 'J' DIM 'B' 28 DIM 'B' 167 DIM 'G' DIM 'D' DIM 'H' 'TOP' 167x167x6 THK EXTERNAL WELDED ANGLE 60x60x3 THK INTERNAL LOOSE 167x167x10 THK ANGLE BASE PLATE SECTION 'A-A' DIM 'B' 17 Ø HOLES FOR F12 FIXINGS 37 106 56 61 130 37 167 4 No. 14 Ø HOLES FOR F15 FIXINGS DIM 'B' 'B' 61 30 56 106 BASE PLATE DETAIL (SCALE 1:5) F12 DIM 'L' 60x60x3 THK LOOSE ANGLE F12 (SCALE 1:5) 25 PLAN VIEW CORNER POST - BOLTED OPTION LOOSE ANGLE 14 Ø HOLES FOR F12 FIXINGS SECTION 'B-B' 35 85 75 'A' DIM 'L' ATTACK FACE 60 DIM 'B' DIM 'B' DIM 'B' 60 DIM 'B' 'A' 130 30 DIM 'B' DIM 'E' (LENGTH OF 60x60x3 THICK ANGLE) 'B' DIM 'B' 17 Ø HOLES FOR F12 FIXINGS DIM 'C' (LENGTH OF 100x100x6 RHS) DIM 'B' DIM 'B' DIM 'B' DIM 'B' DIM 'A' (LENGTH OF 167x167x6 THICK ANGLE) 100x100x6 RHS 167 167x167x10 THK BASE PLATE 167x167x6 THK WELDED ANGLE 10 THK BASE DIM 'K' (O/ALL LENGTH) (SCALE 1:5) Securiclad 6 Ø HOLES FOR F16 FIXINGS 167 DIM 'F' ATTACK FACE 6 28 CUSTOMER DIMS DIM A DIM B DIM C DIM D DIM E DIM F DIM G DIM H DIM J DIM K DIM L DIM 'G' 6 Ø HOLES FOR F16 FIXINGS 6 28 6 Ø HOLES FOR F16 FIXINGS 28 DIM 'J' DIM 'B' 28 167 100 (100) DIM 'B' 167 100x100x6 RHS 'TOP' DIM 'D' DIM 'H' 'TOP' DIM 'J' 100 (100) 6 167x167x6 THK EXTERNAL WELDED ANGLE 60x60x3 THK INTERNAL LOOSE 167x167x10 THK ANGLE BASE PLATE SECTION 'A-A' DIM 'B' 106 56 61 130 61 30 56 106 BASE PLATE DETAIL (SCALE 1:5) F16 F16 F16 110 (SCALE 1:5) 25 60 75 LOOSE ANGLE 6 Ø HOLES FOR F16 FIXINGS SECTION 'B-B' PLAN VIEW CORNER POST - TAMPER OPTION 60x60x3 THK LOOSE ANGLE DIM 'L' 'A' DIM 'L' ATTACK FACE 60 DIM 'B' DIM 'B' DIM 'B' 60 DIM 'B' 'A' 37 37 167 4 No. 14 Ø HOLES FOR F15 FIXINGS DIM 'B' 'B' 6 Ø HOLES FOR F16 FIXINGS 6 Ø HOLES FOR F16 FIXINGS 130 30 DIM 'B' 'B' DIM 'B' DIM 'E' (LENGTH OF 60x60x3 THICK ANGLE) DIM 'C' (LENGTH OF 100x100x6 RHS) DIM 'B' DIM 'B' DIM 'B' DIM 'B' DIM 'A' (LENGTH OF 167x167x6 THICK ANGLE) 100x100x6 RHS 167 167x167x10 THK BASE PLATE 167x167x6 THK WELDED ANGLE 10 THK BASE DIM 'K' (O/ALL LENGTH) (SCALE 1:5) Securiclad SECTION 9 ‘SECURICLAD SE’ SMALL ENCLOSURE 100 10mm THICK PLATE WELDED INTERNALLY. FULL LENGTH OF POST STANDARD CORNER POST. SEE DRG. SEC/DET/40000 (TAMPER) SEE DRG. SEC/DET/40100 (BOLTED) DOOR LINTEL 3 ASCOT DOOR 130 50 200 DOOR POST WITH ADDITIONAL STEEL WELDED INTERNALLY 'B' DOOR HEADER (PANEL 250mm MIN) 130x100x3 THK L DOOR FIXED WITH M10 FIXINGS A11 - 180x180x2 THICK ANGLES. 3 FIXINGS (MIN) SEE DRG. SEC/DET/40400 130 CEILING PANEL 900-1190 WIDTH 100 100x174x10 THK BASE PLT 6 THK 136 200x136x6 THK L SECTION 'A-A' DOOR LINTEL 130x100 BOX 'B' 'C' 130 SR2/SR3/SR4 PANELS. ATTACK FACE. 900-1190 WIDE DOOR LOCKING MECHANISM. SEE DRAWING SEC/SAP/31600/REVA L/H DOOR POST 'A' DOOR LINTEL WELDED IN PLACE 'C' R/H DOOR POST SECTION 'B-B' 'A' 130 DOOR LINTEL 130x100 BOX C10 CHANNEL FLOOR TRACK. SEE DRG. SEC/DET/40800 DOOR POST WITH ADDITIONAL STEEL WELDED INTERNALLY SMALL ENCLOSURE WITH DOOR HEADER ASCOT DOOR A364S - LPS1175 SECURITY DOOR NOTE: THIS DOOR TO BE USED ON ALL SR2, SR3 & SR4 ENCLOSURES NOTE: MINIMUM OVERALL HEIGHT OF ENCLOSURE IS 2500mm MAXIMUM OVERALL HEIGHT IS 3000mm 50 10mm THICK PLATE WELDED INTERNALLY. FULL LENGTH OF POST SECTION 'C-C' Securiclad 100 10mm THICK PLATE WELDED INTERNALLY. FULL LENGTH OF POST STANDARD CORNER POST. SEE DRG. SEC/DET/40000 (TAMPER) SEE DRG. SEC/DET/40100 (BOLTED) 130x100 BOX x 6 THICK DOOR LINTEL 'B' 136 3 200x136x6 THK L SECTION 'A-A' DOOR LINTEL 130x100 BOX SR2/SR3/SR4 PANELS. ATTACK FACE. 900-1190 WIDE 'C' 130 DOOR LOCKING MECHANISM. SEE DRAWING SEC/SAP/31600/REVA ASCOT DOOR 130 50 200 DOOR POST WITH ADDITIONAL STEEL WELDED INTERNALLY 'B' 130x100x3 THK L DOOR FIXED WITH M10 FIXINGS A11 - 180x180x2 THICK ANGLES. 3 FIXINGS (MIN) SEE DRG. SEC/DET/40400 130 CEILING PANEL 900-1190 WIDTH 100 100x174x10 THK BASE PLT 6 THK 'A' L/H DOOR POST DOOR LINTEL WELDED IN PLACE 'C' R/H DOOR POST SECTION 'B-B' 'A' C10 CHANNEL FLOOR TRACK. SEE DRG. SEC/DET/40800 130 DOOR LINTEL 130x100 BOX 50 DOOR POST WITH ADDITIONAL STEEL WELDED INTERNALLY SMALL ENCLOSURE WITH DOOR HEADER 10mm THICK PLATE WELDED INTERNALLY. FULL LENGTH OF POST ASCOT DOOR A364S - LPS1175 SECURITY DOOR NOTE: THIS DOOR TO BE USED ON ALL SR2, SR3 & SR4 ENCLOSURES NOTE: MINIMUM OVERALL HEIGHT OF ENCLOSURE IS 2200mm MAXIMUM OVERALL HEIGHT IS 2500mm SECTION 'C-C' Securiclad ASCOT DOORS MANUFACTURE A SINGLE LEAF DOOR WHICH IS APPROVED FOR USE WITHIN THE SECURICLAD PANEL SYSTEM AND UNDER THE LCPB SCOPE & ACHIEVES AN SR4 RATING. IT HAS A MODIFIED LOCK KEEP DESIGNED TO INCREASE THE RESISTANCE TO ATTACK WITH THE ADDITION OF A 20mm THICK BLOCK OF STAINLESS STEEL WELDED TO THE REAR OF THE LOCK KEEP. Securiclad HOLES FOR M10 BOLTS <*> = DIMS TO SUIT DOOR FRAME 22 DIM 'E' 130 <*> 50 6 Ø FOR F16 FIXINGS 100 (100) 50 100 DIM 'C' 130 B 100 4 <*> 10mm THICK PLATE WELDED INTERNALLY. FULL LENGTH OF LINTEL DIM 'F' CUSTOMER DIMS DIM A DIM B DIM C DIM D DIM E DIM F HOLES FOR M10 BOLTS. SPACINGS TO SUIT DOOR FRAME DOOR LINTEL <*> SECTION 'B-B' (SCALE 1:5) 200 200x136x6 THICK L 6 136 100 DIM 'C' <*> 10mm THICK PLATE WELDED INTERNALLY. FULL LENGTH OF POST <*> DIM 'B' (LENGTH OF 130x100x3 THICK L) (SCALE 1:5) 130x100x3 THICK L 130 SECTION 'A-A' DIM 'C' <*> (SCALE 1:5) 174 100x174x 10 THICK PLATE A 152 22 2 No. 14 Ø HOLES FOR F15 FIXINGS DIM 'D' 28 44 100 <*> 28 A 10 THK DIM 'A' (LENGTH OF 200x136x6 THICK L) <*> B LEFT FRONT POST - AS DRAWN RIGHT FRONT POST - OPP HAND (SCALE 1:10) BASE PLATE DETAIL (SCALE 1:5) Securiclad SECTION 10 FLASHINGS & FIXINGS P2 DECORATIVE FLASHING (0.5mm THICK STEEL) P1 DECORATIVE FLASHING (0.5mm THICK STEEL) P5 DECORATIVE FLASHING (0.5mm THICK STEEL) Securiclad P3 DECORATIVE FLASHING (0.5mm THICK STEEL) P4 DECORATIVE FLASHING (0.5mm THICK STEEL) 190 P1 DECORATIVE FLASHING (0.5mm THICK STEEL) 13 25 190 Securiclad 13 25 P2 DECORATIVE FLASHING (0.5mm THICK STEEL) Securiclad P3 DECORATIVE FLASHING (0.5mm THICK STEEL) 11 55 55 Securiclad 75 11 75 P4 DECORATIVE FLASHING (0.5mm THICK STEEL) Securiclad 11 25 40 180 P5 DECORATIVE FLASHING (0.5mm THICK STEEL) Securiclad 15 F11 5.5mm Ø x 32mm TAMPER DRIVE SELF DRILL SCREWS F13 F14 F16 F17 F18 F12 F15 5.5mm Ø x 38mm TAMPER DRIVE SELF DRILL SCREWS 5.5mm Ø x 61mm TAMPER DRIVE SELF DRILL SCREWS ARGUS SLEEVE ANCHOR 12mm Ø x 60mm LONG 5.5mm Ø x 92mm TAMPER DRIVE SELF DRILL SCREWS M12 ZINC PLATED DOME HEAD BOLT AND TAMPER NUT 5.5mm Ø x 135mm TAMPER DRIVE SELF DRILL SCREWS 5.5mm Ø x 163mm TAMPER DRIVE SELF DRILL SCREWS Securiclad SECTION 11 LOUVERS SECURICLAD PANELS THERE ARE A NUMBER OF HIGH PERFORMANCE SECURITY VENTILATION LOUVRES APPROVED FOR USE WITHIN THE SECURICLAD PANEL SYSTEM AND UNDER THE LCPB SCOPE. THE LOUVRES ARE MANUFACTURED BY BY SURELOCK McGILL AND THEIR TECHNICAL INFORMATION ARE AS FOLLOWS: LOUVRE CK TA AT CE FA SECURITY RATING MAX-AIR-XA1 SR1 MAX-AIR-XA2 SR2 MAX-AIR-XA3 SR3 MAX-AIR-XA4 SR4 SURELOCK McGILL HIGH PERFORMANCE SECURITY VENTILATION LOUVRES Securiclad NOTE:POSITION OF LOUVRE MUST BE A MINIMUM OF 100mm FROM ANY EDGE OF WALLING SYSTEM & A MINIMUM OF 100mm BETWEEN ONE OR MORE LOUVRES.
© Copyright 2025 Paperzz