CODE 31 * MEANING SOLUTION Control board error Remove power for 15 seconds. If code continues, replace control board. Check the operator cable connections, then reprogram the limits. Check for an obstruction, then reprogram the limits. 34 Absolute Position Issue 35 Max-Run-Time Exceeded 36 Product ID Error Was the control board just replaced? If so, erase limits, enter limit setup mode and set limits. If not, disconnect all power, wait 15 seconds, then reconnect power before changing product ID harness. 37 Product ID Failure Unplug product ID harness then plug back in. Disconnect all power, wait 15 seconds, then reconnect power before replacing product ID harness. 38 * Hard Stop Limit may be set too tightly against a hard stop (re-adjust limit). Operator may be at end of travel (re-adjust mounting). 40 Battery overvoltage 41 Battery overcurrent Possible short of the battery charge harness. Check harness. Make sure you do NOT have a 12V battery on a 24V system. 42 No battery at boot up Check battery connections. Replace batteries if depleted to less than 10V on 12V system or 20V on 24V system. 43 Failure or missing exit loop (SHORT or OPEN - LiftMaster Plug-in Loop Detector 44 Failure or missing shadow loop only) Check loop wiring throughout connection. May 45 Failure or missing interrupt loop 46 Low batteries in wireless edge Replace batteries 47 Battery shorted Check battery harness for short to chassis. 50 Run-Distance Error 53 Input voltage too low Gate unbalance detected. Make sure the gate is installed on a level surface and not on an excessive grade. Review power supply and wiring. If rebooting, wait for 15 seconds then reconnect power. 54 Wireless Second Operator Communication Error Check the second operator for power. If OFF, restore power and try to run the system. If powered, deactivate the wireless feature and then re-learn the second operator. 60 No external entrapment protection devices installed Install at least one entrapment protection device (and ensure all entrapment zones are protected). 61 be a short in the loop, or an open connection in the loop. WIRING DIAGRAM CLOSE EYE/INTERRUPT (main board) Input held > 3 minutes. Check input on main board, check for alignment or obstruction. 62 CLOSE EDGE (main board) 63 OPEN EYE/EDGE (main board) 64 65 CLOSE Edge CLOSE EYE/EDGE Input held > 3 minutes. Check input on main board; check for alignment or obstruction. 66 OPEN EYE/EDGE 67 Wireless edge input stuck on Check input for wiring issue or obstruction. 68 Wireless edge lost signal Check batteries, reposition edge receiver for clearer path to operator antenna. 69 * Wireless edge triggered Remove obstruction, check inputs and wiring. 70 * CLOSE EYE/INTERRUPT reversal, preventing close, or resetting TTC 71 * CLOSE EDGE triggered reversal, preventing close, or cancelling TTC IF an obstruction occurred, no action required. If an obstruction did NOT occur, check alignment, inputs, and wiring. 72 * OPEN EYE/EDGE reversal or preventing opening 73 * CLOSE EYE/INTERRUPT reversal, preventing close, or resetting TTC (expansion board) 74 * CLOSE EYE/EDGE reversal and preventing close or cancelling TTC (expansion board) 75 * OPEN EYE/EDGE reversal or preventing opening (expansion board) 80 Close input (EYE/EDGE) fault (Secondary operator) 81 Open input (EYE/EDGE) fault (Secondary Operator) 82 Close input (EYE/EDGE) fault (expansion board) 83 Open input (EYE/EDGE) fault (expansion board) 91 Force reversal 93 Force reversal (RPM) 99 RSL12VDC Normal Operation Check the connections between the main board and the secondary operator. Check the connections between the main board and the expansion board. Check for obstruction. If no obstruction, check that the operator arm is engaged and free to move. Check actuator's wiring. Refer to Limit and Force Adjustment section, and Obstruction Test sections in owner’s manual. No action required * Codes marked with an asterisk are displayed in real time (as the condition occurs) and will not be saved in memory. 01-37331B Antenna Loop Detector Diagnostics (Model LOOPDETLM ) BLUE LED 1 Blink (every 10 seconds) WHITE LED OFF Coaxial Antenna Cable EXPLANATION Normal Operation CONTROL BOARD Jumper Wire ANTENNA + + 2 Blinks Rapid Blinks (active fault) or OFF 3 Blinks Rapid Blinks (active fault) or OFF 4 Blinks Rapid Blinks (active fault) + Open Loop + Shorted Loop + Failed Authentication - - OFF Slow Blinks Loop detector is in TEST or PROG mode - Edge Successful Reset + Photoelectric Sensors Edge + A Primary/Secondary link to other gate operator B COM LINK Active Loop Shielded Twisted Pair Cable J25 Black Red To J25 Ground the shield of the cable to the chassis ground of each operator. Yellow AC & BATT FAIL BACKDRIVE Black Blue Red Transformer Black Black Blocking Diode Red White Black White Black 12V 7AH Battery Product ID Red Red Piezo Alarm Red To Pin 2 - To Pin 1 To Pin 6 + - Run + To Pin 5 One, two, or three 10W Solar Panels wired in parallel (30W maximum) Stop/Reset APS Encoder Reset Switch Red Accessory Power Outlets 1/8 HP 12 Vdc Motor EXPANSION BOARD (Optional) Black TO MAIN BOARD Heater OPEN CLOSE Green POWER 1 EYE ONLY 2 EYE/ EDGE 3 EYE/ EDGE EYE EDGE OR EYE EDGE OR EYE COM OPN GND N L L N GND SBC CLS STP N.C. Field Wiring White Loop Detector COM Input Power Connection SHADOW INTERUPT Jumper Wire EXIT Field Wiring Wire Loop Wire Loop Wire Loop Field Wiring ©2014 LiftMaster All Rights Reserved WARNING: See Installation Manual regarding maintenance and required safety testing prior to servicing. Field Wiring + 2 Blinks Solid Photoelectric Sensors + - OFF Solid N.C. -
© Copyright 2026 Paperzz