Measuring Instructions Insert Double Hung and Glider Measuring Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Insert Casement and Awning Measuring Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Polygon and Round Top Direct Glaze − Inside Opening . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Full Frame Measuring Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Direct Glaze Polygon Measuring Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Direct Glaze Round Top Measuring Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Bow and Bay Measuring Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Full Frame Sliding Door Measuring Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Direct Glaze Polygon Reference . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Fraction to Decimal Conversion . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2013−09−30 Measure−1 2 4 6 7 9 11 13 15 17 20 19915295 Infinity Measuring Instructions INFINITY MEASURING INSTRUCTIONS INSERT DOUBLE HUNG AND GLIDER Before You Begin S These measuring instructions cover the following product types: Infinity Insert Double Hung (NINDH), Infinity Insert Glider (NINGL) S S For existing sill angles less than 8_, the exterior nose of the Infinity Insert sill will rest on the existing sill. See illustration 3b. Be sure to inspect the exterior around the existing window unit for rot or deterioration. If there is damage to the exterior, a full frame unit installation may be a better choice. S It may be necessary to cover the resulting gap (F) with trim. See illustration 3b. S The Infinity Insert will be made with an 8_ sill bevel. For existing sill angles greater than 8_, the interior edge of the Infinity Insert sill will rest on the existing sill. See illustration 3a. A E D D Top of Sill B EXISTING WINDOW FRAME 1 You will need to supply: Tape measure Angle finder C NOTE: Numbers listed in parentheses ( ) are metric equivalents in millimeters rounded to the nearest whole number. 2 EXISTING WINDOW FRAME Required Measurements NOTE: To calculate exact frame size, refer to the sizing/measurement conversions in the Architectural Information section of the Infinity Support Guide. 1. For Inside Opening Width (A) measure inside of frame at three locations: the sill, the center of jambs and the head jamb. Record the narrowest measurement. See illustration 1. NOTE: Do not measure width from parting stops, blind stops, hardware, or weatherstrip. 2. Measure the Inside Opening Height (B) from the top of the sill to the bottom of the head jamb as shown in illustration 2. 3. Measure the Sill Angle (C). Record the sill angle to the nearest degree. See illustration 2. Recommended Measurements 4. Measure the width of the blind stops from the inside opening to the edge of the blind stop (D). See illustration 1. If width exceeds 1/2I (13), modification to the blind stop or an exterior installation may be necessary. 5. Measure jamb pocket depth (E). See illustration1. If depth is less than 3 1/4I (83) or greater than 3 1/2I(89) modification to the pocket may be necessary. (Exterior installation is recommended for pocket depths less than 3 1/4.) Trim Interior Frame Size Interior Inside Frame Size Opening Inside Opening F GAP 3a − 14 Degree Existing Sill 2013−09−30 3b − Flat Existing Sill Measure−2 19915295 Infinity Measuring Instructions INFINITY MEASURING INSTRUCTIONS INSERT DOUBLE HUNG AND GLIDER PROJECT MEASURED BY: DATE: D Top of Sill Follow the steps on the previous page to fill in this worksheet. Measurement A Inside Opening Width (Narrowest Width) Measurement B Inside Opening Height Measurement C Sill Angle Measurement D Blind stop width* Measurement E Jamb pocket depth** NOTE: Insert units will be manufactured 3/8, (10) smaller in width and 1/4, (6) smaller in height than the inside opening measurement specified. B A E D C EXISTING WINDOW FRAME EXISTING WINDOW FRAME Required Measurement Window#/Location Product Description A B Recommended Measurement C D* E** Site Map * ** If blind stop width exceeds 1/2 (13), modifications may be necessary. If less than 3 1/4 (83) or greater than 3 1/2 (89), modifications to the pocket may be necessary. 2013−09−30 Measure−3 19915295 Infinity Measuring Instructions INFINITY MEASURING INSTRUCTIONS INSERT CASEMENT AND AWNING Before You Begin S These measuring instructions cover the following product types: Infinity Insert Casement (NINCA), Infinity Insert Awning (NINAWN) S Be sure to inspect the exterior around the existing window unit for rot or deterioration. If there is damage to the exterior, a full frame unit installation may be a better choice. A E D C Top of Sill B EXISTING WINDOW FRAME 1 D You will need to supply: Tape measure NOTE: Numbers listed in parentheses ( ) are metric equivalents in millimeters rounded to the nearest whole number. 2 EXISTING WINDOW FRAME Required Measurements NOTE: To calculate exact frame size, refer to the sizing/measurement conversions in the individual product chapter. 1. For Inside Opening Width (A) measure inside of frame at three locations: the sill, the center of jambs and the head jamb. Record the narrowest measurement. See illustration 1. NOTE: Do not measure width from parting stops, blind stops, hardware, or weatherstrip. 2. Measure the Inside Opening Height (B) from the top of the sill to the bottom of the head jamb as shown in illustration 2. 3. Measure the Stool Height (C) and record. See illustration 2. If the stool height is over 1 5/16modification to the existing sill may be necessary. See illustration 3. Recommended Measurements 4. Measure the width of the blind stops from the inside opening to the edge of the blind stop (D). See illustration 1. If width exceeds 1/2I (13), modification to the blind stop or an exterior installation may be necessary. 5. Measure jamb pocket depth (E). See illustration1. If depth is less than 3 1/4I (83) or greater than 3 1/2I(89) modification to the pocket may be necessary. (Exterior installation is recommended for pocket depths less than 3 1/4.) Interior Frame Size Interior Inside Frame Opening Size 1 5/16 (33) 1 5/16 (33) 2013−09−30 Inside Opening Measure−4 19915295 Infinity Measuring Instructions INFINITY MEASURING INSTRUCTIONS INSERT CASEMENT AND AWNING PROJECT MEASURED BY: DATE: D Top of Sill Follow the steps on the previous page to fill in this worksheet. Measurement A Measurement B Measurement C Measurement D Measurement E Inside Opening Width (Narrowest Width) Inside Opening Height Stool Height Blind stop width* Jamb pocket depth** B A E D NOTE: Insert units will be manufactured 3/8, (10) smaller in width and 1/4, (6) smaller in height than the inside opening measurement specified. C EXISTING WINDOW FRAME EXISTING WINDOW FRAME Required Measurement Window#/Location Product Description A B Recommended Measurement C D* E** Site Map * ** If blind stop width exceeds 1/2 (13), modifications may be necessary. If less than 3 1/4 (83) or greater than 3 1/2 (89), modifications to the pocket may be necessary. 2013−09−30 Measure−5 19915295 Infinity Measuring Instructions INFINITY MEASURING INSTRUCTIONS POLYGON AND ROUND TOP DIRECT GLAZE − INSIDE OPENING PROJECT MEASURED BY: D DATE: Follow the steps on the previous page to fill in this worksheet. Measurement A Measurement B Measurement D Measurement E Inside Opening Width (Narrowest Width) Inside Opening Height Blind stop width Jamb pocket depth B A E D NOTE: Insert units will be manufactured 3/8, (10) smaller in width and 1/4, (6) smaller in height than the inside opening measurement specified. EXISTING WINDOW FRAME EXISTING WINDOW FRAME Required Measurement Window Product Description A B Recommended Measurement D* E** Location Site Map 2013−09−30 Measure−6 19915295 Infinity Measuring Instructions INFINITY MEASURING INSTRUCTIONS FULL FRAME Before You Begin S These measuring instructions cover the following Infinity product types: Double Hung, Glider, Casement and Awning. Supplied by others You will need to supply: Tape measure Pry bar Sheetrock saw Supplied by others Hammer Utility knife Rough Opening BMC OM NOTE: Numbers listed in parentheses ( ) are metric equivalents in millimeters rounded to the nearest whole number. 1. Frame OM Remove interior trim and if necessary, trim back a section of the interior wall covering back to the Rough Opening of the existing window unit as shown in illustration 1. Remove Supplied by others Existing Window Assembly Rough Opening Supplied by others Rough Opening Height Remove Rough Opening Width 2 NOTE: The above Infinity construction drawing illustrates the flat sill and need to trim back the wall covering to the rough opening. The construction drawing illustrates a suggested method to finish off the Infinity unit using a field applied Infinity Jamb Extension Adaptor. Existing Window Assembly Sill Plate BMC OM NOTE: BMC is not available for bows, bays or doors. Cut Sheetrock through to the R.O. Sill Plate Make cut appr. 2” wide Required Measurements 2. To determine the Rough Opening Width measure the interior dimension as illustrated. 3. Measure the Rough Opening Height from the interior of the rough opening header to the bottom of the opening as illustrated. Sheetrock 1 NOTE: Check the rough opening for any water damage that may need to be repaired prior to installing the Infinity unit. 2013−09−30 Measure−7 19915295 Infinity Measuring Instructions INFINITY MEASURING INSTRUCTIONS FULL FRAME PROJECT Remove MEASURED BY: DATE: Rough Opening Width Follow the steps on the previous page to fill in this worksheet. Existing Window Assembly * The unit will be fabricated 1 smaller than the RO Width ** The Unit will be fabricated 1/2 smaller than the RO Height Remove IMPORTANT: Infinity units with BMC for Masonry Openings: Adjust the RO width and height measurements to accommodate the BMC. Frame OM to BMC OM; width + 2 3/4; height + 1 15/16. Window Location Product Description Rough Opening Height Existing Window Assembly EXISTING WINDOW FRAME EXISTING WINDOW FRAME (Required) (Optional) *(Required) **(Required) Bow/Bay Bow/Bay RO Width RO Height Jamb Depth Projection Site Map * ** If blind stop width exceeds 1/2 (13), modifications may be necessary. If less than 3 1/4 (83) or greater than 3 1/2 (89), modifications to the pocket may be necessary. 2013−09−30 Measure−8 19915295 Infinity Measuring Instructions INFINITY MEASURING INSTRUCTIONS DIRECT GLAZE POLYGON Before You Begin S These measuring instructions cover the following product types: Insert or Full Frame Infinity Polygon S Be sure to inspect the exterior around the existing window unit for rot or deterioration. Repair any damage to the opening before installation of the unit. For insert units If there is damage to the existing window frame, a full frame unit installation may be a better choice. Rough Opening Rough Opening Greater than 1/2” (13) Frame Size 1/2” (13) 1/2” (13) Frame Size Greater than 1/2” (13) Frame Size Rough Opening Frame Size 1/2” (13) Rough Opening 1/2” (13) SPECIAL ANGULAR SHAPE UNIT − RO RECTANGULAR UNIT − RO Inside Opening Inside Opening Greater than 1/4” (6) Frame Size 3/16” (5) 3/16” (5) Frame Size Greater than 3/16” (5) SPECIAL ANGULAR SHAPE UNIT − IO Frame Size Inside Opening Inside Opening 1/4” (6) Frame Size 1/4” (6) RECTANGULAR UNIT − IO On all units, we maintain the clearance or conversion dimension perpendicular to the frame. For this reason, standard rectangular conversions cannot be used for any unit involving angles. These must be calculated on an individual basis. If any dimension is critical (such as frame measurement to match lower unit) then order should be placed with that dimension. The order will be converted to the accurate rough opening. When calculating Angular shapes, contact your Infinity Representative. Inside opening clearance is 3/8 (10) on width and 1/4 (6) perpendicular to frame. Rough opening clearance is 1 (25) on width and 1/2 (13) perpendicular to frame. Masonry opening clearance is 1/2 (13) on width and 1/4 (6) on height perpendicular to frame 2013−09−30 Measure−9 19915295 Infinity Measuring Instructions INFINITY MEASURING INSTRUCTIONS DIRECT GLAZE POLYGON PROJECT MEASURED BY: Remove DATE: Rough Opening Width Follow the steps on the previous page to fill in this worksheet. Existing Window Assembly * The unit will be fabricated 1 smaller than the RO Width ** The Unit will be fabricated 1/2 smaller than the RO Height Rough Opening Height Remove IMPORTANT: Infinity units with BMC for Masonry Openings: Adjust the RO width and height measurements to accommodate the BMC. Frame OM to BMC OM; width + 2 3/4; height + 1 15/16. Existing Window Assembly EXISTING WINDOW FRAME Window Location Product Description EXISTING WINDOW FRAME (Required) (Optional) *(Required) **(Required) Bow/Bay Bow/Bay RO Width RO Height Jamb Depth Projection Site Map * ** If blind stop width exceeds 1/2 (13), modifications may be necessary. If less than 3 1/4 (83) or greater than 3 1/2 (89), modifications to the pocket may be necessary. 2013−09−30 Measure−10 19915295 Infinity Measuring Instructions INFINITY MEASURING INSTRUCTIONS DIRECT GLAZE ROUND TOP Before You Begin S S These measuring instructions cover the following product types: Insert or Full Frame Infinity Round Top Be sure to inspect the exterior around the existing window unit for rot or deterioration. Repair any damage to the opening before installation of the unit. For insert units If there is damage to the existing window frame, a full frame unit installation may be a better choice. Inside Opening Rough Opening 3/16” (5) Frame Size 1/2” (13) 1/4” (6) Frame Size Inside Opening 1/2” (13) Frame Size Rough Opening Frame Size Round Top − RO Round Top − IO B A RT 1 How to Specify Dimensions: When ordering a round top window, provide a sketch of the unit as viewed from the exterior, also include key rough opening dimensions. Example: To order a window for a round top opening, provide measurement A. On all units, we maintain the clearance or conversion dimension perpendicular to the frame. If any dimension is critical (such as frame measurement to match lower unit) then order should be placed with that dimension. The order will be converted to the accurate rough opening. Inside opening clearance is 3/8 (10) on width and 1/4 (6) perpendicular to frame. Rough opening clearance is 1 (25) on width and 1/2 (13) perpendicular to frame. Masonry opening clearance is 1/2 (13) on width and 1/4 (6) on height perpendicular to frame 2013−09−30 Measure−11 19915295 Infinity Measuring Instructions INFINITY MEASURING INSTRUCTIONS DIRECT GLAZE ROUND TOP PROJECT MEASURED BY: Remove DATE: Rough Opening Width Follow the steps on the previous page to fill in this worksheet. Existing Window Assembly * The unit will be fabricated 1 smaller than the RO Width ** The Unit will be fabricated 1/2 smaller than the RO Height Rough Opening Height Remove IMPORTANT: Infinity units with BMC for Masonry Openings: Adjust the RO width and height measurements to accommodate the BMC. Frame OM to BMC OM; width + 2 3/4; height + 1 15/16. Existing Window Assembly EXISTING WINDOW FRAME Window Location Product Description EXISTING WINDOW FRAME (Required) (Optional) *(Required) **(Required) Bow/Bay Bow/Bay RO Width RO Height Jamb Depth Projection Site Map * ** If blind stop width exceeds 1/2 (13), modifications may be necessary. If less than 3 1/4 (83) or greater than 3 1/2 (89), modifications to the pocket may be necessary. 2013−09−30 Measure−12 19915295 Infinity Measuring Instructions INFINITY MEASURING INSTRUCTIONS BOW AND BAY You will need to supply: Before You Begin S This measuring instruction covers the following Infinity product types: Double Hung Bay, Casement Bow and Bay. Tape measure Pry Bar Sheetrock saw Hammer Utility Knife NOTE: Numbers listed in parentheses ( ) are metric equivalents in millimeters rounded to the nearest whole number. 1. Remove interior trim and if necessary, trim a section of the interior wall covering to the Rough Opening of the existing window unit as shown in illustration 1. Required Measurements 2. Measure the Rough Opening Width from jack stud to jack stud. See illustration 1. 3. Measure the Rough Opening Height from the interior of the rough opening header to the sill plate. See illustration 1. 4. Measure the Jamb depth from interior wall to the exterior sheathing. See illustration 1. Remove Rough Opening Width Sill Plate 2 (51) Jamb Depth Sheetrock Existing Window Assembly Rough Opening Height Remove Existing Window Assembly 1 NOTE: Check the rough opening for any water damage that may need to be repaired prior to installing the Infinity unit. 1/2 (13) 1/4 (6) 1 1/8 (29) 1 1/2 (38) 3/8 (10) 2 2013−09−30 Measure−13 19915295 Infinity Measuring Instructions INFINITY MEASURING INSTRUCTIONS BOW AND BAY PROJECT Remove MEASURED BY: DATE: Follow the steps on the previous page to fill in this worksheet. * ** The unit will be fabricated 1 smaller than the RO Width The unit will be fabricated 1/2 smaller than the RO Height C Existing Window Assembly Remove Rough Opening Height Rough Opening Width Jamb Depth Existing Window Assembly C A A Projection Projection 1 3/32 (28) 1 3/32 (28) NINDH BAY A = Projection − 2 15/16 (75) + Jamb Depth B = Projection + 1 3/32 (28) Product Description NINCA BAY A = Projection − 2 7/16 (62) + Jamb Depth B = Projection + 31/32 (24) RO Width* RO Height** B IMPORTANT: For Masonry openings the RO Height must be reduced by 1 1/2 inches to accommodate the bow or bay insulated seat board. See illustration 2. Projection and jamb depth can not exceed 29 inches. Bay Assembly Ratio Bow Unit 1:2:1 or 1:1:1 4, 5, or 6 wide Jamb Depth Site Drawing 2013−09−30 Measure−14 19915295 Infinity Measuring Instructions INFINITY MEASURING INSTRUCTIONS SLIDING DOOR Before You Begin S These measuring instructions cover the following Infinity product type: Special Size Infinity Sliding Patio Door Supplied by others Supplied by others You will need to supply: Tape measure Pry bar Sheetrock saw Hammer Utility knife Frame OM Rough Opening Height NOTE: Numbers listed in parentheses ( ) are metric equivalents in millimeters rounded to the nearest whole number. 1. Remove interior trim and if necessary, trim back a section of the interior wall covering back to the rough opening of the existing window unit. See illustration 1. Remove Rough Opening Width Supplied by others Frame OM Supplied by others Rough Opening Height Existing Door Assembly Supplied by others Supplied by others 2 Remove Rough Opening Width Remove NOTE: The Infinity construction drawing does not include a recommended RO sill panning system. See illustration 2. The construction drawing illustrates a suggested method to finish off the Infinity unit using a field applied exterior casing. Depending upon the depth of the wall it may be necessary to apply an interior jamb extension as well. Required Measurements 1 2. To determine the Rough Opening Width measure the interior dimension as illustrated. 3. Measure the Rough Opening Height from the interior of the rough opening header to the bottom of the opening as illustrated. Existing Door Assembly NOTE: Check the rough opening for any water damage that may need to be repaired prior to installing the Infinity door unit. 2013−09−30 Measure−15 19915295 Infinity Measuring Instructions INFINITY MEASURING INSTRUCTIONS SLIDING DOOR PROJECT Standard Size Sliding Door RO Chart MEASURED BY: 50W DATE: Follow the steps on the previous page to fill in this worksheet. 60W 80W 90W 65H 60 x 80 72 x 80 96 x 80 107 1/2 x 80 68H 60 x 82 1/2 72 x 82 1/2 96 x 82 1/2 107 1/2 x 82 1/2 80H 60 x 96 72 x 96 96 x 96 107 1/2 x 96 Special sized Sliding Patio Doors (NSPD) will be fabricated as follows: 1 (25) smaller than the RO Width* and 1/2 (13) smaller than the RO Height** Door Jamb Depth for standard and special sized doors is 4 9/16 (116) Door Location Product Description *(Required) **(Required) (Optional) RO Width RO Height Jamb Depth Site Map 2013−09−30 Measure−16 19915295 Infinity Measuring Instructions INFINITY MEASURING INSTRUCTIONS DIRECT GLAZE POLYGON REFERENCE B B B P3−1 C C P3−2 A B A P4−5 P4−6 A A TRAPEZOID 90 TRIANGLE B B C P3−5 P5−1 A A ISOSCELES TRIANGLE PENTAGON HEXAGON B P8−1 A A OCTAGON 90 RECTANGLE How to Specify Dimensions: When ordering a trapezoid, triangle, or rectangle window, provide a sketch of the unit as viewed from the exterior, also include key rough opening dimensions. Example: To order a window of a trapezoid opening, provide the measurements of A, B, and C as indicated. For other shapes, give the dimensions shown. 2013−09−30 Measure−17 19915295 Infinity Measuring Instructions INFINITY MEASURING INSTRUCTIONS DIRECT GLAZE POLYGON REFERENCE Rough Opening Conversion Information * 0.6870 11/16 (17) 1/2 (13) Rough Opening 1/2 (13) Frame OSM 0.5000 1/2 (13) Pitch (P1) * 1.6262 1 5/8 (41) * These dimensions will vary according to pitch Inside Opening Conversion Information * 0.8232 5/16 (8) 1/4 (6) Inside Opening 3/16 (5) Frame OSM 0.2500 1/4 (6) Pitch (P1) * 0.8134 13/16 (21) * These dimensions will vary according to pitch On all units, we maintain our clearance or conversion dimension perpendicular to the frame (see sketch). For this reason standard rectangular conversions cannot be used for any unit involving a radius or angles. These must be calculated on an individual basis. If any dimension is critical (such as frame O.S.M. to match lower unit) then the order should be placed with that dimension and Infinity will calculate the accurate dimensions needed. 2013−09−30 Measure−18 19915295 Infinity Measuring Instructions INFINITY MEASURING INSTRUCTIONS DIRECT GLAZE POLYGON REFERENCE ANGLE TO PITCH CHART ANGLE PITCH 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 ANGLE PITCH .21/12 .42/12 .63/12 .84/12 1.05/12 1.26/12 1.47/12 1.69/12 1.90/12 2.12/12 2.33/12 2.55/12 2.77/12 2.99/12 3.21/12 3.44/12 3.67/12 3.90/12 4.13/12 4.37/12 4.61/12 4.85/12 5.09/12 5.34/12 5.59/12 5.85/12 6.11/12 6.38/12 6.65/12 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 ANGLE PITCH 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 6.93/12 7.21/12 7.50/12 7.79/12 8.09/12 8.40/12 8.72/12 9.04/12 9.37/12 9.71/12 10.07/12 10.43/12 10.80/12 11.19/12 11.58/12 12/12 12.42/12 12.86/12 13.32/12 13.80/12 14.30/12 14.81/12 15.35/12 15.92/12 16.51/12 17.13/12 17.78/12 18.47/12 19.20/12 19.96/12 20.78/12 21.64/12 22.56/12 23.54/12 24.59/12 25.72/12 26.94/12 28.25/12 29.68/12 31.24/12 32.95/12 34.82/12 36.90/12 39.22/12 41.81/12 44.74/12 48.08/12 51.92/12 56.38/12 61.65/12 67.95/12 75.63/12 85.22/12 97.51/12 113.87/12 136.72/12 170.91/12 227.73/12 PITCH TO ANGLE CHART 13/12 PITCH = 47 17’ 14/12 PITCH = 49 24’ 15/12 PITCH = 51 20’ 16/12 PITCH = 53 22’ 17/12 PITCH = 54 47’ 18/12 PITCH = 56 19’ 19/12 PITCH = 57 43’ 20/12 PITCH = 59 02’ 21/12 PITCH = 60 15’ 22/12 PITCH = 60 23’ 23/12 PITCH = 62 27’ 24/12 PITCH = 63 26’ 1/12 PITCH = 4 46’ 2/12 PITCH = 9 28’ 3/12 PITCH = 14 02’ 4/12 PITCH = 18 26’ 5/12 PITCH = 22 37’ 6/12 PITCH = 26 34’ 7/12 PITCH = 30 15’ 8/12 PITCH = 33 41’ 9/12 PITCH = 36 52’ 10/12 PITCH = 39 48’ 11/12 PITCH = 42 31’ 12/12 PITCH = 45 2013−09−30 Measure−19 19915295 Infinity Measuring Instructions INFINITY MEASURING INSTRUCTIONS FRACTION TO DECIMAL CONVERSION 1 1 1/16 17 .046875 3 9/16 7 1/8 37 19 .109375 9 5 5/8 11 3/16 41 21 .171875 13 7 11/16 15 1/4 45 23 .234375 17 9 3/4 19 5/16 49 25 .296875 21 11 13/16 23 3/8 53 27 .359375 25 13 7/8 27 7/16 57 29 .421875 29 15 15/16 31 61 31 .484375 .921875 .9375 .453125 .46875 .890625 .90625 59 .4375 .859375 .875 .390625 .40625 .828125 .84375 55 .375 .796875 .8125 .328125 .34375 .765625 .78125 51 .3125 .734375 .75 .265625 .28125 .703125 .71875 47 .25 .671875 .6875 .203125 .21875 .640625 .65625 43 .1875 .609375 .625 .140625 .15625 .578125 .59375 39 .125 .546875 .5625 .078125 .09375 .515625 .53125 35 .0625 5 2013−09−30 33 .03125 3 1/2 .015625 .953125 .96875 63 .984375 .5 Measure−20 19915295 Infinity Measuring Instructions
© Copyright 2026 Paperzz