With flexible, kink-resistant ® INTRODUCERS you get everything you need to succeed. Reaching your destination in complex interventional procedures requires the skill to pick the best route and the strength and flexibility to move smoothly through difficult terrain. The unique sheath construction in Cook Flexor Introducers provides optimal flexibility and maximum resistance to kinking or compression. On suitably configured devices, an AQ® hydrophilic coating dramatically reduces friction to enhance deliverability, while Flexor’s large, low-friction PTFE-coated lumen facilitates device delivery. A radiopaque band on the tip of devices commonly delivered under fluoroscopy assures vibrant visualization to help guide your way. Available in one of the industry’s broadest selections of need-specific shapes and configurations, there’s a Flexor Introducer for the most demanding bracheocephalic, renal and iliofemoral procedures. With Cook’s broad line of Flexor Introducers, you have the strength and flexibility to approach your most challenging cases with confidence. Large, Low Friction Lumen Large PTFE lumen facilitates unconstrained device delivery. .074" 5 Fr .087" 6 Fr .100" 7 Fr .113" 8 Fr .126" 9 Fr .134" 10 Fr Flexor® Check-Flo® Introducer Sets Small Valve Assembly Used to introduce balloon, closed and non-tapered end catheters or other devices for intervention. The maximum diameter of the instrument or catheter to be introduced should be determined to ensure its passage through the sheath.1 • Uniquely fabricated sheath design to provide maximum flexibility without kinking or compression. • Radiopaque band, incorporated within sheath material, identifies precise location of sheath’s distal tip for positioning accuracy. • Check-Flo® hemostasis valve accepts a broad range of sizes while preventing blood reflux and air aspiration. STRAIGHT AND CURVED SAFE-T-J® DOUBLE FLEXIBLE TIPPED WIRE GUIDE Stainless steel appropriate length Radiopaque Band Opti-Loc® Fitting ORDER NUMBER KCF-8.0-38-J INTRODUCER DILATOR Radiopaque INTRODUCER SHEATH Radiopaque French Size Wire Guide Diameter Wire Guide Type Sheath Length Global Product Number 8.0 .038 inch straight/3 mm J 13 cm G07663 1Introducer1 RB™ Design Radiopaque Band–Wire Guide Not Included KCFW-6.0-38-RB 6.0 .038 inch 13 cm G08681 KCFW-7.0-38-RB 7.0 .038 inch 13 cm G11211 KCFW-8.0-38-RB 8.0 .038 inch 13 cm G07856 KCFW-9.0-38-RB 9.0 .038 inch 13 cm G07857 8.0 .038 inch 25 cm G09185 Long Lengths–Wire Guide Not Included KCFW-8.0-38-25 RB™ Design Radiopaque Band–Wire Guide Not Included KCFW-6.0-38-30-RB 6.0 .038 inch 30 cm G08867 KCFW-7.0-38-30-RB 7.0 .038 inch 30 cm G08246 KCFW-7.0-38-80-RB 7.0 .038 inch 80 cm G09901 KCFW-8.0-38-30-RB 8.0 .038 inch 30 cm G07878 KCFW-8.0-38-80-RB 8.0 .038 inch 80 cm G09994 KCFW-9.0-38-30-RB 9.0 .038 inch 30 cm G07465 Flexor® Check-Flo® Introducer Sets Micropuncture® Radial Artery Access Used to introduce balloon, diagnostic and guiding catheters or other devices for intervention. The maximum diameter of the instrument or catheter to be introduced should be determined to ensure its passage through the sheath.1 • Uniquely fabricated sheath design to provide maximum flexibility without kinking or compression. • Initial access is gained using a 21 gage entry needle. • .018 inch nitinol wire guide with platinum tip is advanced through the needle and the needle removed. • Introducer dilator incorporates a van Andel taper to facilitate placement into the vessel. • Check-Flo® hemostasis valve accepts a broad range of sizes while preventing blood reflux and air aspiration. • AQ® hydrophilic coating, when wet, provides an extremely low coefficient of friction, easing introduction into the vascular system. MICROPUNCTURE® WIRE GUIDE Nitinol MICROPUNCTURE® NEEDLE 21 gage appropriate length AQ® Hydrophilic Coating SYRINGE (3 each) ORDER NUMBER Taper length 2.5 cm INTRODUCER DILATOR Radiopaque with distal 8 cm AQ® hydrophilic coated Opti-Loc® Fitting 1Introducer1 French Size Wire Guide Diameter INTRODUCER SHEATH Radiopaque Sheath Length Dilator Taper Length Needle Length Global Product Number AQ® Hydrophilic Coating, Nitinol Wire Guide–Platinum tip KCFN-5.0-18-7-RA2.5-HC 5.0 .018 inch 7 cm 2.5 cm 4 cm G12659 KCFN-5.0-18-13-RA2.5-HC 5.0 .018 inch 13 cm 2.5 cm 4 cm G12660 KCFN-5.0-18-23-RA2.5-HC 5.0 .018 inch 23 cm 2.5 cm 4 cm G12661 KCFN-6.0-18-7-RA2.5-HC 6.0 .018 inch 7 cm 2.5 cm 4 cm G11607 KCFN-6.0-18-13-RA2.5-HC 6.0 .018 inch 13 cm 2.5 cm 4 cm G11604 KCFN-6.0-18-13-RA2.5S-HC 6.0 .018 inch 13 cm 2.5 cm 2.5 cm G11679 KCFN-6.0-18-23-RA2.5-HC 6.0 .018 inch 23 cm 2.5 cm 4 cm G11605 KCFN-6.0-18-23-RA2.5S-HC 6.0 .018 inch 23 cm 2.5 cm 2.5 cm G11680 KCFN-7.0-18-13-RA2.5-HC 7.0 .018 inch 13 cm 2.5 cm 4 cm G11608 KCFN-7.0-18-23-RA2.5-HC 7.0 .018 inch 23 cm 2.5 cm 4 cm G11609 Flexor® Check-Flo® Introducer Set Micropuncture® Access – Medical College of Ohio Modification Used to introduce balloon, diagnostic and guiding catheters or other devices for intervention. The maximum diameter of the instrument or catheter to be introduced should be determined to ensure its passage through the sheath.1 • Uniquely fabricated sheath design to provide maximum flexibility without kinking or compression. • Initial access is gained using 21 gage entry needle. • .018 inch nitinol wire guide with platinum tip is advanced through needle and needle removed. Upon removal of entry needle, coaxial dilator is introduced. • Removal of inner dilator and wire guide facilitates placement of .035 or .038 inch diameter wire guide through outer dilator. • Check-Flo® hemostasis valve accepts broad range of sizes while preventing blood reflux and air aspiration. • Lubricous surface, provided by AQ® hydrophilic coating, eases introduction into the vascular system. MICROPUNCTURE® WIRE GUIDE Nitinol MICROPUNCTURE® NEEDLE 21 gage appropriate length SYRINGE AQ® Hydrophilic Coating Opti-Loc® Fitting ORDER NUMBER COAXIAL INTRODUCER DILATOR(S) Radiopaque INTRODUCER SHEATH Radiopaque 1Introducer1 French Size Wire Guide Diameter Sheath Length Needle Length Global Product Number 2.5 cm G12603 AQ® Hydrophilic Coating, RB™ Design Radiopaque Band – Nitinol Wire Guide KCFN-6.0-18-23-MCO-HC 6.0 .018 inch 23 cm Flexor® Check-Flo® Introducers Raabe Modification Used to introduce balloon, closed and non-tapered end catheters or other devices for intervention. The maximum diameter of the instrument or catheter to be introduced should be determined to ensure its passage through the sheath.1 • Uniquely fabricated sheath design to provide maximum flexibility without kinking or compression. • Short dilator tip enhances trackability and facilitates positioning of introducer assembly in tight spaces. • Radiopaque band, incorporated within sheath material, identifies precise location of sheath’s distal tip for positioning accuracy. • Check-Flo® hemostasis valve accepts broad range of sizes while preventing blood reflux and air aspiration. Radiopaque Band Opti-Loc® Fitting ORDER NUMBER INTRODUCER DILATOR Radiopaque INTRODUCER SHEATH Radiopaque 1Introducer1 French Size Accepts Wire Guide Diameter Sheath Length Global Product Number RB™ Design Radiopaque Band – Wire Guide Not Included KCFW-5.0-38-55-RB-RAABE 5.0 .038 inch 55 cm G13009 KCFW-6.0-38-55-RB-RAABE 6.0 .038 inch 55 cm G11638 KCFW-6.0-38-70-RB-RAABE 6.0 .038 inch 70 cm G11636 KCFW-6.0-38-90-RB-RAABE 6.0 .038 inch 90 cm G12266 KCFW-7.0-38-55-RB-RAABE 7.0 .038 inch 55 cm G11633 KCFW-7.0-38-70-RB-RAABE 7.0 .038 inch 70 cm G11635 KCFW-7.0-38-90-RB-RAABE 7.0 .038 inch 90 cm G11634 KCFW-8.0-38-55-RB-RAABE 8.0 .038 inch 55 cm G12242 KCFW-8.0-38-70-RB-RAABE 8.0 .038 inch 70 cm G11637 Flexor® Check-Flo® Introducers Balkin Up & Over® Contralateral Design Used for contralateral access to the iliac artery for interventional procedures after initial wire guide positioning has been established. NOTE: Use of a heavy-duty wire guide is recommended. The maximum diameter of the instrument or catheter to be introduced should be determined to ensure its passage through the sheath.1 • Available in a wide range of sizes (5.5 Fr thru 12.0 Fr). • Optional AQ® hydrophilic coating on sheath (distal 15 cm) significantly reduces coefficient of friction thereby facilitating easier insertion and improved trackability. • Patented sheath design provides maximum flexibility without kinking or compression. • Radiopaque band, seamlessly incorporated within sheath material, identifies precise location of distal tip for positioning accuracy. • Check-Flo® valve prevents blood reflux and air aspiration during catheter manipulations. Opti-Loc® dilator hub secures dilator to introducer valve assembly to prevent dilator movement during insertion. Opti-Loc® Fitting INTRODUCER SHEATH Radiopaque Radiopaque Band ORDER NUMBER 1Introducer French Size Accepts Wire Guide Diameter Sheath Length Global Product Number RB™ Design Radiopaque Band – Wire Guide Not Included KCFW-5.5-38-40-RB-BLKN 5.5 .038 inch 40 cm G12656 KCFW-6.0-35-40-RB-BLKN 6.0 .035 inch 40 cm G10406 KCFW-6.0-38-40-RB-BLKN 6.0 .038 inch 40 cm G10383 KCFW-7.0-35-40-RB-BLKN 7.0 .035 inch 40 cm KCFW-7.0-38-40-RB-BLKN 7.0 .038 inch 40 cm KCFW-8.0-38-40-RB-BLKN 8.0 .038 inch 40 cm G10385 KCFW-10.0-38-40-RB-BLKN 10.0 .038 inch 40 cm G32372 KCFW-12.0-38-40-RB-BLKN 12.0 .038 inch 40 cm G32374 G10405 ˜ G10384 AQ® Hydrophilic Coating RB™ Design Radiopaque Band – Wire Guide Not Included KCFW-5.5-38-40-RB-BLKN-HC 5.5 .038 inch 40 cm G32208 KCFW-6.0-35-40-RB-BLKN-HC 6.0 .035 inch 40 cm G32223 KCFW-6.0-38-40-RB-BLKN-HC 6.0 .038 inch 40 cm G32224 KCFW-7.0-35-40-RB-BLKN-HC 7.0 .035 inch 40 cm G32212 KCFW-7.0-38-40-RB-BLKN-HC 7.0 .038 inch 40 cm G32225 KCFW-8.0-38-40-RB-BLKN-HC 8.0 .038 inch 40 cm G32216 Flexor® Tuohy-Borst Side-Arm Introducers Balkin Up & Over® Contralateral Design Used for contralateral access to the iliac artery for interventional procedures after initial wire guide positioning has been established. NOTE: Use of a heavy-duty wire guide is recommended. The maximum diameter of the instrument or catheter to be introduced should be determined to ensure its passage through the sheath.1 • Uniquely fabricated sheath design to provide maximum flexibility without kinking or compression. • Sheath and dilator configuration facilitates positioning over bifurcation to opposite iliac artery. • Radiopaque band, incorporated within sheath material, identifies precise location of sheath’s distal tip for positioning accuracy. • Use of opened Tuohy-Borst manual-adjusting valve seal permits unimpeded catheter or device introduction. Closed valve position prevents blood reflux, air aspiration and movement of positioned catheter. Clear Body Tuohy-Borst Side-Arm Adapter Opti-Loc® Fitting INTRODUCER SHEATH Radiopaque Radiopaque Band ORDER NUMBER 1Introducer1 French Size Accepts Wire Guide Diameter Sheath Length Global Product Number RB™ Design Radiopaque Band – Wire Guide Not Included KSAW-6.0-38-45-RB-BLKN-SI 6.0 .038 inch 45 cm G10634 KSAW-7.0-38-45-RB-BLKN-SI 7.0 .038 inch 45 cm G10635 Flexor® Check-Flo® Introducers Ansel Modification Used to introduce balloon, closed and non-tapered end catheters or other devices for intervention. The maximum diameter of the instrument or catheter to be introduced should be determined to ensure its passage through the sheath.1 • .018 and .038 inch wire compatible dilators included. • Uniquely fabricated sheath design to provide maximum flexibility without kinking or compression. • Preformed curves combined with soft, distal tip allow atraumatic engagement of target vessels. • Short dilator tip enhances trackability and facilitates positioning of introducer assembly in tight spaces. • Radiopaque band, incorporated within sheath material, identifies precise location of sheath’s distal tip for positioning accuracy. • Check-Flo® hemostasis valve accepts broad range of sizes while preventing blood reflux and air aspiration. • AQ® hydrophilic coating on both sheath and dilator provide an extremely lubricious surface, easing introduction. AQ® Hydrophilic Coating INTRODUCER DILATORS Radiopaque (2 each) Opti-Loc® Fitting ANL1 ANL2 Radiopaque Band INTRODUCER SHEATH Radiopaque with distal 30 cm AQ® hydrophilic coating ANL3 Radiopaque Band(s) ORDER NUMBER AQ® 1Introducer1 French Size Accepts Wire Guide Diameter Sheath Length Global Product Number Hydrophilic Coating, RB™ Design Radiopaque Band – Wire Guide Not Included KCFW-5.0-18/38-45-RB-ANL1-HC 5.0 .018/.038 inch 45 cm G29981 KCFW-5.0-18/38-45-RB-ANL2-HC 5.0 .018/.038 inch 45 cm G30117 KCFW-5.0-18/38-45-RB-ANL3-HC 5.0 .018/.038 inch 45 cm G30118 KCFW-6.0-18/38-45-RB-ANL1-HC 6.0 .018/.038 inch 45 cm G29982 KCFW-6.0-18/38-45-RB-ANL2-HC 6.0 .018/.038 inch 45 cm G29983 KCFW-6.0-18/38-45-RB-ANL3-HC 6.0 .018/.038 inch 45 cm G29984 KCFW-7.0-18/38-45-RB-ANL1-HC 7.0 .018/.038 inch 45 cm G29985 KCFW-7.0-18/38-45-RB-ANL2-HC 7.0 .018/.038 inch 45 cm G29986 KCFW-7.0-18/38-45-RB-ANL3-HC 7.0 .018/.038 inch 45 cm G29987 Flexor® Tuohy-Borst Side-Arm Introducers Ansel Modification Used to introduce balloon, closed and non-tapered end catheters or other devices for intervention. The maximum diameter of the instrument or catheter to be introduced should be determined to ensure its passage through the sheath.1 • .018 and .038 inch wire compatible dilators included. • Uniquely fabricated sheath design to provide maximum flexibility without kinking or compression. • Preformed curves combined with soft, distal tip allow atraumatic engagement of target vessels. • Short dilator tip enhances trackability and facilitates positioning of introducer assembly in tight spaces. • Radiopaque band, incorporated within sheath material, identifies precise location of sheath’s distal tip for positioning accuracy. • Use of opened Tuohy-Borst manual-adjusting valve seal permits unimpeded catheter or device introduction. Closed valve position prevents blood reflux, air aspiration and movement of positioned catheter. • AQ® hydrophilic coating on both sheath and dilator provide an extremely lubricious surface, easing introduction. AQ® Hydrophilic Coating INTRODUCER DILATORS Radiopaque (2 each) Opti-Loc® Fitting ANL1 ANL2 Radiopaque Band COOK INTRODUCER SHEATH Radiopaque with distal 30 cm AQ® hydrophilic coating ANL3 Radiopaque Band(s) ORDER NUMBER 1Introducer1 French Size Accepts Wire Guide Diameter Sheath Length Global Product Number AQ® Hydrophilic Coating, RB™ Design Radiopaque Band – Wire Guide Not Included KSAW-5.0-18/38-55-RB-ANL1-HC 5.0 .018/.038 inch 55 cm G29995 KSAW-5.0-18/38-55-RB-ANL2-HC 5.0 .018/.038 inch 55 cm G30120 KSAW-5.0-18/38-55-RB-ANL3-HC 5.0 .018/.038 inch 55 cm G30121 KSAW-6.0-18/38-55-RB-ANL1-HC 6.0 .018/.038 inch 55 cm G29996 KSAW-6.0-18/38-55-RB-ANL2-HC 6.0 .018/.038 inch 55 cm G29997 KSAW-6.0-18/38-55-RB-ANL3-HC 6.0 .018/.038 inch 55 cm G29998 KSAW-7.0-18/38-55-RB-ANL1-HC 7.0 .018/.038 inch 55 cm G29999 KSAW-7.0-18/38-55-RB-ANL2-HC 7.0 .018/.038 inch 55 cm G30000 KSAW-7.0-18/38-55-RB-ANL3-HC 7.0 .018/.038 inch 55 cm G30001 Flexor® Tuohy-Borst Side-Arm Introducers Shuttle®–SL Used for the introduction of catheters, balloons or other vascular devices. The maximum diameter of the instrument or catheter to be introduced should be determined to ensure its passage through the sheath.1 • 5.0 French for small vessel intervention with .018 and .038 inch wire compatible dilators included. • Uniquely fabricated sheath design to provide maximum flexibility without kinking or compression. • Radiopaque band, incorporated within sheath material, identifies precise location of sheath’s distal tip for positioning accuracy. • Atraumatic SL (soft landing) tip design reduces vessel trauma during engagement. • AQ® hydrophilic coating provides an extremely lubricious surface area for enhanced trackability. • Tuohy-Borst manual-adjusting valve seal minimizes blood loss during device insertion. Clear Body Tuohy-Borst Side-Arm Adapter COOK ORDER NUMBER Radiopaque Band 6 Fr. 7 Fr. 8 Fr. .087” .100” .113” 1Introducer1 French Size INTRODUCER SHEATH Radiopaque with distal 50 cm AQ® hydrophilic coated Accepts Wire Guide Diameter INTRODUCER DILATOR(S) Radiopaque with distal 15 cm AQ® hydrophilic coated Sheath Length Global Product Number AQ® Hydrophilic Coating, RB™ Design Radiopaque Band, Two Dilators Included – Wire Guide Not Included KSAW-5.0-18/38-90-RB-SHTL-HC 5.0 .018/.038 inch 90 cm G30009 AQ® Hydrophilic Coating, RB™ Design Radiopaque Band, One Dilator Included – Wire Guide Not Included KSAW-6.0-38-90-RB-SHTL-HC 6.0 .038 inch 90 cm G13264 KSAW-7.0-38-80-RB-SHTL-HC 7.0 .038 inch 80 cm G13338 KSAW-7.0-38-90-RB-SHTL-HC 7.0 .038 inch 90 cm G12835 KSAW-8.0-38-90-RB-SHTL-HC 8.0 .038 inch 90 cm G12836 Ex Pro tra S xim upp al ort Sh aft Flexor® Tuohy-Borst Side-Arm Introducer Shuttle® Select Used for the introduction of catheters, balloons or other vascular devices. The maximum diameter of the instrument or catheter to be introduced should be determined to ensure its passage through the sheath.1 • Uniquely fabricated sheath design to provide maximum flexibility without kinking or compression. • Radiopaque band, incorporated within sheath material, identifies precise location of sheath’s distal tip for positioning accuracy. • Stiffened proximal shaft design enables superior trackability and support for devices. • Atraumatic tip with unique transition zone reduces vessel trauma during engagement. • Selective feature that allows the sheath to be paired with a compatible selective catheter (sold separately), minimizing the exchange of parts. • AQ® hydrophilic coating provides an extremely lubricous surface area for enhanced trackability. • Tuohy-Borst manual-adjusting valve seal minimizes blood loss during device insertion. Clear Body Tuohy-Borst Side-Arm Adapter 3 cm 5 cm 3.2 cm Radiopaque Band INTRODUCER SHEATH Radiopaque with distal 50 cm AQ® hydrophilic coated COOK ORDER NUMBER AQ® 1Introducer1 French Size Accepts Wire Guide Diameter Sheath Length INTRODUCER DILATOR Radiopaque with distal 8 cm AQ® hydrophilic coated Global Product Number Hydrophilic Coating, RB™ Design Radiopaque Band – Wire Guide Not Included KSAW-6.0-38-90-RB-SHTL-FLEX-HC 6.0 .038 inch 90 cm G31138 Flexor® Check-Flo® Introducers Large Valve Assembly Used to introduce large balloon, closed and non-tapered end catheters or other devices for intervention. The maximum diameter of the instrument or catheter to be introduced should be determined to ensure its passage through the sheath.1 • Uniquely fabricated sheath design to provide maximum flexibility without kinking or compression. • Radiopaque band, incorporated within sheath material, identifies precise location of sheath’s distal tip for positioning accuracy. • Check-Flo® hemostasis valve accepts broad range of sizes while preventing blood reflux and air aspiration. Radiopaque Band Opti-Loc® Fitting ORDER NUMBER INTRODUCER DILATOR Radiopaque INTRODUCER SHEATH Radiopaque 1Introducer1 French Size Accepts Wire Guide Diameter Sheath Length Global Product Number Long Lengths–RB™ Design Radiopaque Band – Wire Guide Not Included KCFW-10.0-38-30-RB 10.0 .038 inch 30 cm G13032 KCFW-10.0-38-80-RB 10.0 .038 inch 80 cm G13033 Distributed by: COOK MEDICAL INCORPORATED P.O. Box 4195, Bloomington, IN 47402-4195 U.S.A. Phone: 812 339-2235, Toll Free: 800 457-4500, Toll Free Fax: 800 554-8335 COOK (CANADA) INC. 111 Sandiford Drive, Stouffville, Ontario, L4A 7X5 CANADA Phone: 905 640-7110, Toll Free: 800 668-0300 Diagnostic and Interventional Products www.cookmedical.com WILLIAM A. COOK AUSTRALIA PTY. LTD. Brisbane Technology Park, 12 Electronics Street, Eight Mile Plains Brisbane, QLD 4113 AUSTRALIA, Phone: +61 7 38 41 11 88 WILLIAM COOK EUROPE ApS Sandet 6, DK-4632, Bjaeverskov, DENMARK, Phone: +45 56 86 86 86 © COOK INCORPORATED 2004 KCF804
© Copyright 2026 Paperzz