Valve/Actuator Combinations and Operating Pressure Differentials 2-Way and 3-Way Globe Valve Assemblies Note: Choose a valve assembly with a maximum operating differential pressure capability sufficient for the application. Consult Table-1 on page 5 for close-off pressure ratings. Not all actuator and valve body combinations are offered as factory assemblies. Two-Way Electric Non-Spring Return Models Table-8 2-Way Globe Valve Assemblies with Electric Non-Spring Return Actuators Mx-631x3 Mx41-634x Non-Spring Return 2-Way Globe Valve Assemblies Actuator Output Rating (Minimum) 210 lbf (935 N) 300 lb-in (34 N-m) Actuator Model (Actuator Code) Floating MF-63103 (301) MF-63123 (303) Proportional MF-63123-211 (423) a MF-63123-411 (422)b Floating MF41-6343 (516) Proportional MS41-6340 (512) MS41-6341 (514) MS41-6343 (516) Linkage Kit Part Number AV-672 (2-1/2” to 5”) Valve Assembly Part Numberc Vx-8213-xxx-5-P Vx-8223-xxx-5-P a b c d e 8 P Code Valve Size in. Cv d kvsd 12 2-1/2 56 48 13 3 85 74 14 4 145 125 15 5 240 208 16 6 370 320 AV-609 (6”) Maximum Allowable Operating Differential Pressuree, psi (kPa) — 35 (240) — — — — 35 (240) MF-63123-211 includes MFC-8000 control module factory set for 6-9 Vdc control signal. May be field adjusted for other ranges. Actuator, control module, linkage, and valve body included with factory valve assembly. Components may be purchased separately for field assembly. MF-63123-411 includes MFC-420 control module factory set for 4-20 mAdc control signal. May be field adjusted for other ranges. Actuator, control module, linkage, and valve body included with factory valve assembly. Components may be purchased separately for field assembly. See Globe Valve Assembly Part Numbering System and Selection Procedure to determine a specific part number. kvs = m 3/h (ΔP = 100 kPa) kvs = Cv / 1.156 Cv = gpm / ΔP (in psi). Maximum allowable differential across the valve in any open position. Less than 20 psi recommended for quieter service. Consult Table-1 on page 5 for close-off pressure ratings. © Copyright 2006 TAC. All rights reserved. F-27199-2 2-Way and 3-Way Globe Valve Assemblies Note: Choose a valve assembly with a maximum operating differential pressure capability sufficient for the application. Consult Table-1 on page 5 for close-off pressure ratings. Not all actuator and valve body combinations are offered as factory assemblies. Three-Way Electric Non-Spring Return Models Table-9 3-Way Globe Valve Assemblies with Electric Non-Spring Return Actuators Mx-631x3 Mx41-634x Non-Spring Return 3-Way Globe Valve Assemblies Actuator Output Rating (minimum) 210 lbf (935N) 300 lb-in (34 N-m) Actuator Models (Actuator Codes) Floating MF-63103 (301) MF-63123 (303) Proportional MF-63123-211 (423) a MF-63123-411 (422)b Floating MF41-6343 (516) Proportional MS41-6340 (512) MS41-6341 (514) MS41-6343 (516) Linkage Kit Part Number AV-672 (2-1/2” to 5”) Valve Assembly Part Numberc P Code 12 Vx-8303-xxx-5-P 13 14 15 16 a b c d e f g h i Valve Size in. 2-1/2 Cv d kvsd 80f 69f g 82g 95 AV-609 (6”) Maximum Allowable Operating Differential Pressuree, psi (kPa) (Mixing/Diverting) — 115h 99h 110f 95f 120g 104g 120h 104h 4 190i 164i — 5 290 i 251i — 500 i i 3 6 433 35 (240) / 35 (240) — — 32 ( 219) / 28 (192) MF-63123-211 includes MFC-8000 control module factory set for 6-9 Vdc control signal. May be field adjusted for other ranges. Actuator, control module, linkage, and valve body included with factory valve assembly. Components may be purchased separately for field assembly. MF-63123-411 includes MFC-420 control module factory set for 4-20 mAdc control signal. May be field adjusted for other ranges. Actuator, control module, linkage, and valve body included with factory valve assembly. Components may be purchased separately for field assembly. See Globe Valve Assembly Part Numbering System and Selection Procedure to determine a specific part number. kvs = m 3/h (ΔP = 100 kPa) kvs = Cv / 1.156 Cv = gpm / ΔP (in psi). Maximum allowable differential across the valve in any open position. Less than 20 psi recommended for quieter service. Consult Table-1 on page 5 for close-off pressure ratings. Mixing configuration, ports A and B are inlets, AB port is outlet. Diverting configuration, flow AB to A port. Diverting configuration, flow AB to B port. All flow configurations, mixing or diverting. F-27199-2 © Copyright 2006 TAC. All rights reserved. 9 Globe Valve Bodies Table-1 Specifications for Globe Valve Bodies Application Chilled or Hot Water, Steam Flanged Size Valve Body Valve Body Action Flow Type Body Seat Stem Material Plug Packing Seat Ring ANSI Pressure Class, psig Maximum Inlet Pressure Steam psig (kPa) VB-8213 VB-8223 VB-8303 2-1/2” to 6” VB-8213-0-5-P 2-Way Stem Open (Normally open if spring return actuator) Equal % Cast Iron Forged Brass Stainless Steel Forged Brass Spring Loaded TFE/EPDM EPDM 2-1/2” to 6” VB-8223-0-5-P 2-Way Stem Up Closed (Normally closed if spring return actuator) Equal % Cast Iron Forged Brass Stainless Steel Forged Brass Spring Loaded TFE/EPDM EPDM 125 2-1/2” to 6” VB-8303-0-5-P 3-Way Mixing/Divertinga (Normally stem up if spring return actuator) Modifier Linear Cast Iron Forged Brass Stainless Steel Forged Brass Spring Loaded TFE/EPDM None 35 (240) 125 (856)c Close-Off Pressure, psi (kPa) b c d e f g — 20°F to 281°F (−7°C 138°C) Allowable Control Media Temperature, °F ( °C)b a Chilled or Hot Water 35 (240)c Cv (kvs ) Mixingd P Code Valve Size, In. Cv (kvs ) 12 2-1/2 56 (48) 56 (48) 13 14 15 16 3 4 5 6 85 (74) 145 (125) 240 (208) 370 (320) 85 (74) 145 (125) 240 (208) 370 (320) 80 (69) 110 (95) 190 (164) 290 (251) 500 (433) Cv (kvs ) Divertingd 95 (82)e 115 (99)f 120 (104) g 190 (164)g 290 (251)g 500 (433)g VB-8303 valves will also operate satisfactorily as two-way angle valves if either end (side) port is closed off. CAUTION: Freeze protection required for temperatures below 32°F (0 °C). Avoid ice formation on stems. Valve in closed position. See Table-8 to Table-13 for maximum allowable differential pressure for valve in any open position. VB-8303 may be piped as either mixing or diverting, bottom (AB) port common. Diverting configuration, flow AB to A ports. Diverting configuration, flow AB to B ports. All diverting flow configurations, flow AB to either A or B ports. F-27199-2 © Copyright 2006 TAC. All rights reserved. 5 Electric and Pneumatic Actuators and Linkages Table-2 Floating and Proportional Non-Spring Return Electric Jackscrew and TAC DuraDrive Actuators Power Input @ 50/60 Hz VA Voltage Watts Running Holding Actuator Part Number Actuator Code Control Signal MF-63103 MF-63123 301 303 MF-63123-211 423 MF-63123-411 422 MF41-6343b 516 MS41-6341b 514 MS41-6340b 512 MS41-6343b 516 Floating (SPDT) Proportional (Vdc) Proportional (mAdc) Floating (SPDT) Propotional (Vdc or mAdc) Propotional (Vdc or mAdc) Propotional (Vdc or mAdc) a b Output Force or Torque Timing, sec.a 50 HZ 60 HZ 24 Vac +10%/-15% 6.7 — 6.4 <120 <144 24 Vac ±20% 7.1 3.6 3.8 <145 <145 240 Vac ±10% 7.1 5.0 4.8 <145 <145 120 Vac ±10% 7.1 5.0 4.8 <145 <145 24 Vac ±10% 7.1 5.0 4.8 <145 <145 Manual Override 210 lbf (935 N) 300 lb-in (34 N-m) 300 lb-in (34 N-m) 300 lb-in (34 N-m) 300 lb-in (34 N-m) Yes Approximate timing @ 70°F (21°C) with no load Actuator plus linkage is available as an assembly by adding -220 (AV-607 linkage) or -230 (AV-609 linkage) after the actuator number. Refer to Table 7 for a complete offering. Mx41-634x is not compatible with the AV-607 linkage. Table-3 Two-Position, Floating, and Proportional Spring Return Electric 220 lbf TAC DuraDrive Linear Actuators Actuator Part Number Actuator Code MA61-7200 MA61-7201 595 594 MA61-7203 596 MF61-7203 596 MS61-7203 596 a Control Signal Type Power Input Running 50 Hz 60 Hz VA W VA W Voltage 50/60 Hz 2-Position (SPST or Triac) Floating (SPDT) Proportional (Vdc or mAdc) 120 Vac ±10% 230 Vac ±10% 24 Vac ±20% 22-30 Vdc 24 Vac ±20% 22-30 Vdc 24 Vac ±20% 22-30 Vdc Timing, Secondsa Holding DC 50 Hz 60 Hz Spring Amp Powered Return W W 11.7 8.8 10.0 8.4 15.5 9.5 10.6 8.5 - 3.6 4.6 5.0 3.3 9.8 7.5 9.7 7.5 0.29 2.8 2.8 9.8 7.7 9.7 7.7 0.3 3.3 3.3 9.8 7.4 9.7 7.4 0.28 2.9 2.9 <190 <40 Output Force, lbf (N) Manual Override 220 (979) minimum 495 (2202) max. stall Yes Approximate timing @ 70°F (21°C) with no load Table-4 Two-Position, Floating and Proportional Spring Return Electric 133 lb-in TAC DuraDrive Actuators Actuator Part Number Actuator Code MA41-7150c d MA41-7151c 552 554 MA41-7153c 556 MF41-7153c 556 MS41-7153c 556 a b c d 6 Control Signal Type 2-Position (SPST) Floating (SPDT) Proportional (Vdc or mAdc) Voltage 50/60 Hz 120 Vac ±10% 230 Vac ±10% 24 Vac ±20% 22-30 Vdc 24 Vac ±20% 22-30 Vdc 24 Vac ±20% 22-30 Vdc Power Input Running 50 Hz 60 Hz VA W VA W 11.7 8.8 10.0 8.4 15.5 9.5 10.6 8.5 9.8 7.5 9.7 Holding DC 50 Hz 60 Hz Amp W W - 7.5 0.29 3.6 4.6 5.0 3.3 2.8 2.8 9.8 7.7 9.7 7.7 0.3 3.3 3.3 9.8 7.4 9.7 7.4 0.3 2.9 2.9 Timing, Secondsa Powered Spring Return <190 <30 Torque, Manual lb-in Override (N-m)b 133 (15) Yes Approximate timing @ 70°F (21°C) with no load De-rating required for spring return actuators at low temperatures Actuator plus linkage is available as an assembly by adding -220 (AV-607 linkage) or -230 (AV-609 linkage) after the actuator number. Refer to Table 7 for a complete offering. The CE Directive is not applicable to this model © Copyright 2006 TAC. All rights reserved. F-27199-2 Valve Assemblies with MF-631x3 and MF-63123 Series Non-Spring Return 210 lbf Electric Linear Actuators Actuator Specifications Inputs Control Signal MF-63103 and MF-63123a: SPDT Floating Control, Triacs (1 A rated) or 2 SPST contacts. MF-63123-211: includes MFC-8000 control module set for 6 to 9 Vdc control signal; actuator extend point adjustable 0 to 12 Vdc; span adjustable 2 to 10 Vdc. MF-63123-411: includes MFC-420 control module set for 4 to 20 mAdc control signal; actuator extend point adjustable 2 to 16 mAdc; span adjustable 4 to 16 mAdc. Power Requirements Voltage: 24 Vac +10%/-15% @ 50/60 Hz. Power Input: 6.7 VA; 6.4 W running. 0 VA, 0 W holding. All 24 Vac circuits are Class 2. Connections Screw terminals; conduit knockout. MFC control modules plug into actuator circuit board. Motor Type Synchronous. Outputs Electrical MF-63123: 15k Ω feedback potentiometerb. Auxiliary switch: Available on MF-631x3-500 models. SPDT adjustable over actuator stroke. Rated 1A @ 24 Vac 50/60 Hz, 24 VA @ 24 Vac pilot duty rating. Mechanical Output force rating: 210 lbf (935 N) minimum. Timing: 120 seconds at 60 Hz, 144 seconds at 50 Hz. Position indicator: Provided. Manual override: Activated by the manual override crank. Linear stroke: Up to maximum of 1” (25 mm) nominal, self adjusting. Environment Temperature Limits Shipping and storage: -40° to 160°F (-40° to 71°C) ambient. Operating: 0° to 140°F (-18° to 60°C) ambient temperature. Maximum allowable ambient 125°F (52°C) at maximum valve fluid temperature of 281°F (138°C). Minimum allowable valve fluid temperature 20°F (-7°C). Humidity 5 to 95% RH, non-condensing. Locations NEMA Type 1 Agency Listings (Actuator) a b UL UL 873, Underwriters Laboratories (File # E9429 Category Temperature-Indicating and Regulating Equipment). European Community EMC Directive (89/336/EEC). c-UL Canadian Standards C22.2 No. 24-93. MFC-8000 control module may be installed for Vdc control or MFC-420 control module may be installed for mAdc control. Not available when MFC control modules are used. F-27199-2 © Copyright 2006 TAC. All rights reserved. 17 Dimensions - 2-1/2” to 5” Flanged Globe Valve Assemblies Valve Assembly Part Number 2-Way Vx-8213-30x-5-P Vx-8213-42x-5-P 3-Way Vx-8303-30x-5-P Vx-8303-42x-5-P 2-Way Vx-8223-30x-5-P Vx-8223-42x-5-P Valve Size p Code 2-1/2” 12 3” 13 4” 14 5” 15 2-1/2” 12 3” 13 4” 14 5” 15 A 8-9/16 (217) 9-1/2 (241) 11-1/2 (292) 13 (330) 8-9/16 (217) 9-1/2 (241) 11-1/2 (292) 13 (330) Valve Dimensions in inches (millimeters) 2-Way (Refer to Figure-4) 3-Way (Refer to Figure-5) C E F G A C E F 13-5/16 5-1/2 8-9/16 5-7/16 10-1/4 7 (178) 7 (178) 4 (102) (140) (217) (138) (260) (338) 12-5/8 9-1/2 6-3/8 10-1/2 7-1/2 4-5/8 7-1/2 6 (152) (241) (162) (267) (191) (117) (191) (320) 11-1/2 8-7/16 12-3/8 7-1/2 11-1/4 5-1/12 9 (229) 9 (229) (191) (214) (286) (140) (292) (315) 6-15/16 14-15/16 10 8-1/2 13 8-13/16 14-15/16 10 (176) (379) (254) (216) (330) (224) (379) (254) 5-1/2 9-9/16 7 (178) 4 (102) — — — — (243) (140) 4-1/4 11-1/16 7-1/2 6 (152) — — — — (108) (281) (191) 7-1/2 4-15/16 13-3/4 — — — — 9 (229) (191) (125) (349) 5-7/16 16-1/16 10 8-1/2 — — — — (138) (408) (254) (216) 7-1/2 (191) 8-1/2 (216) — — — — 8-1/4 (210) 8-1/4 (210) E E C C G G F A A Figure-4 Mx-631x3 Series with Flanged 2-Way Globe Valves 18 6 (152) 3-3/4 (95) 5-3/4 (146) 3-3/4 (95) 5-3/4 (146) G 5-1/2 (140) F Figure-5 Mx-631x3 Series with © Copyright 2006 TAC. All rights reserved. Flanged 3-Way Globe Valves F-27199-2
© Copyright 2026 Paperzz