SEISMIC Rx® Code Compliant Solution

Recycled
Content:
30%
Seismic Rx® Code Compliant Solution
Suspension Systems ICC-ESR-1308
Key Selection
Attributes
Armstrong Seismic Rx
Suspension System Saves
Time and Money
ESR-1308 Lists Specific Components and Method of Installation
The performance of the Armstrong Seismic Rx Suspension System is based on a specific combination of components and
method of installation. Other manufacturersw components and installation methods were not tested and are not covered in
this evaluation. Substitution of other components puts the system at risk and is not allowed by this ESR report.
IBC Category C:
Components:
• Easier to square the system by
installing tight to adjacent walls
Select a component from each section (A, B and C).
• Tighter, more secure installation
• Eliminate stabilizer bars
IBC Category D, E, F:
• Reduce material costs by using
7/8" molding
• Eliminate stabilizer bars
• Eliminate installation hassles
from 2" wall molding
ICC-ES Recognizes the
Armstrong Seismic Rx
Suspension System as a
Code Compliant Solution
The independent and expert
evaluation and confirmation by
ICC-ES provides the code official
with proven evidence supporting the
Armstrong Seismic Rx Suspension
System as a code-compliant
alternative design to current IBC
requirements.
3/8"
7/8"
Design Categories D, E and F
Heavy-duty Heavy-duty Heavy-duty Heavy-duty Heavy-duty Heavy-duty Heavy-duty Heavy-duty
A. Suspension Systems
PRELUDE® XL® 15/16" Exposed Tee System
PRELUDE XL Fire Guard™ 15/16" Exposed Tee System
PRELUDE XL 15/16" Environmental Tee System
SILHOUETTE® XL 1/4" Reveal 9/16" Bolt Slot System
SILHOUETTE XL 1/8" Reveal 9/16" Bolt Slot System
SUPRAFINE® XL 9/16" Exposed Tee System
SUPRAFINE XL Fire Guard 9/16" Exposed Tee System
INTERLUDE® XL 9/16" Dimensional Tee System
AL PRELUDE PLUS XL 15/16" Environmental Tee System
SONATA™ 9/16" Dimensional Tee System
SS PRELUDE PLUS XL 15/16" Environmental Tee System
Design
Category C
Intermediate-duty
Intermediate-duty
Intermediate-duty
Intermediate-duty
Intermediate-duty
Intermediate-duty
Intermediate-duty
Intermediate-duty
Intermediate-duty
Intermediate-duty
Intermediate-duty
All Design Categories:
B. Components:
1. Angle molding: hemmed with
prefinished exposed flanges
2a. S hadow molding: hemmed
with prefinished exposed
flanges
Item #
7800
7802 7803 7809 HD7801
780036
Item #
Reveal
7823 (A)
(B)
Length Flange Height
144"7/8"7/8" 120"7/8"7/8"
144"7/8"7/8"
144"15/16"15/16"
120"7/8"7/8"
144"7/8"7/8"
Length
(A)
Flange
(B)
Height
B
A
7804PER
6/17/98
(C)
120"2"1-1/4"3/4"
B
C
A
2b. S hadow Molding (Compatible
with BERC and BERC 2)
7877 7878 7897 120"15/16"15/16" 120"15/16"15/16" 120"15/16"15/16" 1/4"
3/8"
1/2"
shadow molding
Note: Shadow molding can be rotated to be used with either flange
C. Accessories:
3 . Beam End Retaining Clip
joins main beam or cross tee
to wall molding and web of
grid with no visible pop rivets
BERC2, AL BERC2
BERC
BERC BERC2 AL BERC2
7804PRO1/3/98
Angle Molding
Armstrong
AL BERC2
NOTE: It is REQUIRED to
attach a screw through
the ALBERC2 into the
wall molding as shown.
Please visit www.icc-es.org
for a copy of the ESR report.
P
Seismic Rx® Code Compliant Solution
Suspension Systems ICC-ESR-1308
Category D, E, F
Attached Wall
Attached Wall
BERC2 with Seismic Shadow Molding
BERC2 with Angle Molding
OR
Pop Rivets with Angle Molding
B or P
B or P
B or P
B
8" Max.
8" Max.
8" Max.
B
7/8"
X
X
X
X
X
B
7/8"
7/8"
X
Tight Screw
Angle Molding
7878
Unattached Wall
BERC2
Pop Rivet
Unattached Wall
B
B
B
BERC2 with Angle Molding
BERC2 with Seismic Shadow Molding
B
8" Max.
Screw recommended
but optional
Silhouette Main Beam
2' o.c.
Screw optional
BERC2
B
Shadow
Molding
7877
7/8"
3/4"
X
X
B
B
B
Unattached Wall
X Hanger Wire
B BERC or BERC2 Clip
P Pop Rivets
Category C
Tight Wall
BERC2
BERC
B
B
B
B
Tight screw
Main
Beam
Tight screw
B
X
X
B
7/8"
7/8"
Main
Beam
Tight Wall
Tight Wall
Tight Wall
B
BERC
X
X
Cross
Tee
B
BERC2
Cross
Tee
B
X
X
B
7/8"
3/8"
Clearance Wall
3/8"
2' o.c.
7/8"
Clearance Wall
B
X
B
X
B
B
3/8" Clearance Wall
To download CAD drawing details go to armstrong.com/seismic
NOTE: For complete seismic installation requirements contact TechLine
TechLineSM / 1 877 ARmSTRONG
1 877 276 7876
armstrongceilings.com/
suspensionsytems
CS-3751-1111
All trademarks used herein are the property of AWI Licensing Company and /or its affiliates
© 2011 AWI Licensing Company • Printed in the United States of America
X Hanger Wire
B BERC or BERC2 Clip