C:\Documents and Settings\Chip Murrah\My Documents\Downloads

REVISIONS
27'-8"
20'
CHIP MURRAH
ARCHITECT
10" X 24" CONC FTG W/ (2) #4'S CONTIN
404 273 2555
6'-814"
8'-7"
6'-214"
6'-214"
RIDGE- 2x12
HVAC
MECH'L/
STORAGE
10'-10" X 16'-2"
12'-5" X 11'-5"
DEN
A NEW RESIDENCE
HVAC
2X8's 16" O.C.
SLOPE 4:12
WH
2X8's 16" O.C.
SLOPE 4:12
WH
GAME ROOM
V
CRICKET
49'-412"
DIRECT VENT F.P. ABOVE
Y
LE
L
A
1'
8'-614"
17'-014"
3046 DH
4'-6"
4'-643"
1'
VALLEY
11'-10"
SD
BATH
STORAGE
4'
VALLEY
OUTSIDE OF FRAMING ABOVE
2X8's 16" O.C.
SLOPE 12:12
VALLEY
This plan is the property of
Chip Murrah and may not be used or
reproduced without his permission.
1'-4"
10" X 24" CONC FTG W/ (2) #4'S CONTIN
11'-4"
3'-11"
1'-4"
8'
4" CONC. SLAB W/ 6 X 6 10/10 WWF
W/ 24" X 10" CONC. FTG. W/ (2) #4's
SLOPE TO DRAIN
TAPERED BRICK ABOVE
1'-4"
1'-4"
2X8's 16" O.C.
SLOPE 12:12
12'-10" X 11'-5"
2'-1"
5'-8"
STORAGE
13'-5" X 4'-4"
VALLEY
2X8's 16" O.C.
SLOPE 5.25:12
7'-4"
5'-2"
2X8's 16" O.C.
SLOPE 5.25:12
1'-4"
CLOSET
4'-312"
VALLEY
1'-4"
18'-9" X 17'-11"
UP
RIDGE- 2x12
2X8's 16" O.C.
SLOPE 12:12
STORAGE
3'
RIDGE- 2x12
10'-10" X 5'-6"
18'-9"
6'
14'-3"
19'-7"
RIDGE- 2x12
VALLEY
2X8's 16" O.C.
SLOPE 12:12
35'-914"
16'-3"
27'-314"
18'-212"
61'-414"
15'-5" X 21'-5"
Chip Murrah assumes no liability for any home
constructed from this plan. It is the responsibility of the
purchaser of this plan to conduct the following before
commencing construction.
1. Builder or contractor must verify all dimensions,
structural requirements, and specifications before
commencing actual construction.
2 X 4 FRAMED WALL
22'-8"
UNFINISHED
BASEMENT PLAN
SCALE: 1/4" = 1'-0"
INDICATES 10" POURED CONC. WALL W/ BRICK LEDGE
ON 24" X 10" CONC. FTG. W/ (2) #4's CONTIN.
2. Builder or contractor must verify compliance with all
local, state and federal building codes and regulations
where the home is to be constructed.
1'-4"
BRICK STEP ABOVE
5'-4"
3. Plans indicate locations only. Builder or contractor
will analyze & incorporate any and all structural
engineering aspects in order to construct the home prior
to starting. Architect is not respobsible for sturctural
aspects.
4'-5"
Caution must be exercised in making any changes to this
plan. Only a qualified designer, architect, contractor or
structural engineer should make changes to this plan.
Minor changes could lead to major problems.
ROOF PLAN
24"
SECTION THRU
GRADE BEAM
NORCROSS, GA 30071
19'-8"
3068 FR DR
ASTORIA LOT #10
22'-1"
4" CONC. SLAB W/ 6 X 6 10/10 WWF
W/ 24" X 10" CONC. FTG. W/ (2) #4's
1'-4"
1'
3052 DH
2X8's 16" O.C.
SLOPE 6:12
1'-4"
7'-7"
4'-9"
11'-6"
12'-2"
RETAINING WALL AS REQUIRED
DECK ABOVE
2X8's 16" O.C.
SLOPE 6:12
SLOPE TO DRAIN
17'-7"
NEW P.T. 6 X 6 ON 18" X 18" CONC.
FTG W/ (2) #4's EA. WAY (TYP.)
SCALE: 1/4" = 1'-0"
DATE
5/19/14
SCALE: 1/2" = 1'-0"
RELEASED FOR CONSTRUCTION
JOB #
A U G U S T 2 1, 2 0 1 4
DRAWN
SHEET
W.H.
A-3