REVISIONS 27'-8" 20' CHIP MURRAH ARCHITECT 10" X 24" CONC FTG W/ (2) #4'S CONTIN 404 273 2555 6'-814" 8'-7" 6'-214" 6'-214" RIDGE- 2x12 HVAC MECH'L/ STORAGE 10'-10" X 16'-2" 12'-5" X 11'-5" DEN A NEW RESIDENCE HVAC 2X8's 16" O.C. SLOPE 4:12 WH 2X8's 16" O.C. SLOPE 4:12 WH GAME ROOM V CRICKET 49'-412" DIRECT VENT F.P. ABOVE Y LE L A 1' 8'-614" 17'-014" 3046 DH 4'-6" 4'-643" 1' VALLEY 11'-10" SD BATH STORAGE 4' VALLEY OUTSIDE OF FRAMING ABOVE 2X8's 16" O.C. SLOPE 12:12 VALLEY This plan is the property of Chip Murrah and may not be used or reproduced without his permission. 1'-4" 10" X 24" CONC FTG W/ (2) #4'S CONTIN 11'-4" 3'-11" 1'-4" 8' 4" CONC. SLAB W/ 6 X 6 10/10 WWF W/ 24" X 10" CONC. FTG. W/ (2) #4's SLOPE TO DRAIN TAPERED BRICK ABOVE 1'-4" 1'-4" 2X8's 16" O.C. SLOPE 12:12 12'-10" X 11'-5" 2'-1" 5'-8" STORAGE 13'-5" X 4'-4" VALLEY 2X8's 16" O.C. SLOPE 5.25:12 7'-4" 5'-2" 2X8's 16" O.C. SLOPE 5.25:12 1'-4" CLOSET 4'-312" VALLEY 1'-4" 18'-9" X 17'-11" UP RIDGE- 2x12 2X8's 16" O.C. SLOPE 12:12 STORAGE 3' RIDGE- 2x12 10'-10" X 5'-6" 18'-9" 6' 14'-3" 19'-7" RIDGE- 2x12 VALLEY 2X8's 16" O.C. SLOPE 12:12 35'-914" 16'-3" 27'-314" 18'-212" 61'-414" 15'-5" X 21'-5" Chip Murrah assumes no liability for any home constructed from this plan. It is the responsibility of the purchaser of this plan to conduct the following before commencing construction. 1. Builder or contractor must verify all dimensions, structural requirements, and specifications before commencing actual construction. 2 X 4 FRAMED WALL 22'-8" UNFINISHED BASEMENT PLAN SCALE: 1/4" = 1'-0" INDICATES 10" POURED CONC. WALL W/ BRICK LEDGE ON 24" X 10" CONC. FTG. W/ (2) #4's CONTIN. 2. Builder or contractor must verify compliance with all local, state and federal building codes and regulations where the home is to be constructed. 1'-4" BRICK STEP ABOVE 5'-4" 3. Plans indicate locations only. Builder or contractor will analyze & incorporate any and all structural engineering aspects in order to construct the home prior to starting. Architect is not respobsible for sturctural aspects. 4'-5" Caution must be exercised in making any changes to this plan. Only a qualified designer, architect, contractor or structural engineer should make changes to this plan. Minor changes could lead to major problems. ROOF PLAN 24" SECTION THRU GRADE BEAM NORCROSS, GA 30071 19'-8" 3068 FR DR ASTORIA LOT #10 22'-1" 4" CONC. SLAB W/ 6 X 6 10/10 WWF W/ 24" X 10" CONC. FTG. W/ (2) #4's 1'-4" 1' 3052 DH 2X8's 16" O.C. SLOPE 6:12 1'-4" 7'-7" 4'-9" 11'-6" 12'-2" RETAINING WALL AS REQUIRED DECK ABOVE 2X8's 16" O.C. SLOPE 6:12 SLOPE TO DRAIN 17'-7" NEW P.T. 6 X 6 ON 18" X 18" CONC. FTG W/ (2) #4's EA. WAY (TYP.) SCALE: 1/4" = 1'-0" DATE 5/19/14 SCALE: 1/2" = 1'-0" RELEASED FOR CONSTRUCTION JOB # A U G U S T 2 1, 2 0 1 4 DRAWN SHEET W.H. A-3
© Copyright 2026 Paperzz