NATIONAL - STANDARDS COMMISSION WEIGHTS & MEASURES (PATTERNS OF INSTRUMENTS) REGULATIONS REGULATION 9 CERTIFICATE This is pattern to certify and variont that an opproval of the has been by N.G. Brown & Associates Pty 7 Albert Street, Richmond, Victoria, 3121 Ltd, Griffin and George submitted are suitable for The OF APPROVAL No 6/1/l Minor use for granted by the Commission that the Beam Balance trade. opproval of the pattern is subject to review on or after l/B/86. instrumentspurporting to comply with this approval shall be marked NSC 6/l/l. All Relevant drawings ond specificationsare lodged with the NO Commission. Signed i’7 Executive Director DescriptiveAdvice Pattern: approved 19/l O/81 A non-self-indicatingbeam balance of intervals. . approved Variant: With I. 1 I81 g capacity by 0.01 g scale 19/10/81 1000 CM.capacityby 0.05 CM scale intervols. Technical Schedule No b/l/l 16/l 200 dated 16/11/81 describes the pattern and variant I. NATIONAL STANDARDS TECHNICAL Pattern: Griffin Submittor: N.G. and Brown George Minor COMMISSION SCHEDULE No 6/1/l Beam Balance and Associates Pty Ltd, 7 Albert Street, Richmond, Victoria, 3121 Descriptionof Pattern 1. 1.1 pattern is an ungraduoted, non-self-indicatingequal-arm beam weighing instrument of 200 g capacity with an assigned verification scale intervol of The load receptorsand hangers are not interchangeable and 0.01 g (Figure 1). are marked left and right. The Levelling 1.2 instrument is provided with a level indicatorand three levelling feet, two Adjacent to the level indicator is a notice advising which are adjustable. thot the instrumentmust be level when in US. The of Marking 1.3 The nameplate is marked with the following dato: Manufacturer’s name NSC approval number Accuracy class in the form: Moximum capacity in the form: NSC No 6/1/l ca Max 200 Min 0.5 Minimum capacity in the form: Verificationscale interval in the form: The instrument Descriptionof Variant 2.1 Variant 1 maximum capacity of 1000 CM, and an except 0.05 CM. The balance is unchanged for the pattern, with the for the markings scale interval below. following exceptions: Maximum Capacity Minimum Capacity VerificationScale Interval 16/l assigned verification Markings 2.1 .I As g is also marked NOT FOR RETAIL COUNTER USE. 2. With e = 0.01 g g l/81 Max q 1000 CM Min = 2.5 CM e = 0.05 CM of TEST PROCEDURE No 6/1/l 1. Accuracy The maximum permissibleerrors are: t0.5e zle Requirements for for loads loads between between 0 and 5OOOe 5OOle and 20 OOOe Sensitivity 2. A mass equal to the absolute value of the moximum permissible error at the load considered , placed on the instrument at equilibrium,loaded or unloaded, should cause a permanentdisplacement of the index of at least 1 mn. This test should be done in conjunction with 4. below for at least zero and full lood. Level Sensitivity 3. instrument is tilted tilt should not be more than position the instrumentshould When the Load 4. so thot the end of the plum bob moves 2 mn, the 1 in 500, and when zero is reset in the tilted satisfy the above accuracy requirements, Test Test loads ore to be opplied to the instrument in not less than 5 approximotely equal steps with the first equal to the minimum capacity, increasing to maximum capacity, followed by decreasing loads of not less than 5 approximately equal steps. 16/l l/81 FIGURE Griffin 16/11/81 and George 61111 Minor - 1 Beam Balance
© Copyright 2026 Paperzz