lumenfacade™
INSTALLATION INSTRUCTIONS
drawing number 111904
This product must be installed in accordance with applicable national and local electrical and construction
codes by a person familiar with the construction and operation of the product and the hazards involved.
Failure to comply with the following installation instructions may result in death or serious injury.
!
!
WARNING
!
CAUTION
WARNING
DO NOT EXCEED FIXTURE SPECIFIED VOLTAGE.
DO NOT USE IF FIXTURE, PARTS OR CONNECTORS ARE DAMAGED.
WHITE & STATIC COLORS
COLOR CHANGING &
DYNAMIC WHITE
UNAUTHORIZED FIELD REPAIRS WILL VOID WARRANTY.
ASYMMETRIC WALLWASH OPTIC OPTION
WALL
NOTICE
RECOMMENDED SETBACK FROM WALL IS
1/10 OF THE WALL HEIGHT.
TOP VIEW
ALWAYS POSITION FROSTED SIDE
TOWARD THE WALL.
EXAMPLE: 2FT SETBACK FOR A 20FT WALL
FRONT VIEW
RIGHT SIDE VIEW
(Fixture pointing upwards)
STEP 1. SLIDE IN SAM MOUNTING BRACKETS
STEP 2. TIGHTEN SCREWS
4X
HEX KEY SIZE: 3/32"
STEP 3. SCREW ONTO MOUNTING SURFACE
R 1"
8
[4mm]
31
8"
[79mm]
3
28 "
[60mm]
2 13 "
16
[71mm]
OR
STEP 1. SLIDE IN UMAS MOUNTING BRACKETS
LOOSEN SCREWS
SLIGHTLY TO ADJUST LIGHT
BEAM ORIENTATION AND
RE-TIGHTEN TO SECURE
4X
HEX KEY SIZE: 5/32"
STEP 2. TIGHTEN SET SCREWS
4X
HEX KEY SIZE: 1/8"
STEP 3. SCREW ONTO MOUNTING SURFACE
Ø9 "
32
[7mm]
!
3
4"
[19mm]
3
8"
[10mm]
!
DO NOT LOOK INTO BEAM.
13 "
2 1"
2
4
[45mm] [64mm]
WARNING
CAUTION
USE 1/4” FASTENERS (4X BY OTHERS)
THAT ARE APPROPRIATE FOR USE WITH
YOUR MOUNTING SURFACE
LOOSEN SCREWS
SLIGHTLY TO ADJUST LIGHT
BEAM ORIENTATION AND
RE-TIGHTEN TO SECURE
2X
HEX KEY SIZE: 3/16"
OR
STEP 1. SLIDE IN WAM MOUNTING BRACKETS
STEP 2. TIGHTEN SET SCREWS
4X
HEX KEY SIZE: 1/8"
STEP 3. SCREW ONTO MOUNTING SURFACE
9
32 "
[7mm]
!
WARNING
USE 1/4” FASTENERS (4X BY OTHERS)
THAT ARE APPROPRIATE FOR USE WITH
YOUR MOUNTING SURFACE
1
"
16
[27mm]
1
1
3
2 "
1 4 "
2
[64mm]
[45mm]
!
CAUTION
DO NOT LOOK INTO BEAM.
LOOSEN NUTS & BOLTS
SLIGHTLY TO ADJUST LIGHT
BEAM ORIENTATION AND
RE-TIGHTEN TO SECURE
bin™, a proprietary binning method, guarantees color temperature consistency within a 3-step MacAdam ellipse.
™
Combine lumentranslator with Lumentalk-enabled luminaires housing Lumenpulse's proprietary lumenear control card to build your Lumentalk system.
p.1/2
Lumenpulse, 1751 Richardson, Suite 1505, Montreal (Quebec) Canada H3K 1G6 1.877.937.3003 P. 514.937.3003 F. 514.937.6289
[email protected] www.lumenpulse.com
Copyright © Lumenpulse 2015
Confidential and proprietary
07/DE/2015
S.Ayite - Rev.4
Lumenpulse reserves the right to make changes to this product and related instructions at any time without prior notice
and such changes shall be effective immediately. See www.lumenpulse.com/support/downloads for current data and instructions.
lumenfacade™
INSTALLATION INSTRUCTIONS
drawing number 111904
!
This product must be installed in accordance with applicable national and local electrical and construction
codes by a person familiar with the construction and operation of the product and the hazards involved.
Failure to comply with the following installation instructions may result in death or serious injury.
WHITE & STATIC COLORS
COLOR CHANGING &
DYNAMIC WHITE
OR
STEP 1. SLIDE IN UMP MOUNTING BRACKETS
STEP 2. TIGHTEN SET SCREWS
4X
HEX KEY SIZE: 1/8"
*UMP BRACKETS CAN BE ADJUSTED HORIZONTALLY.
STEP 3. SCREW ONTO MOUNTING SURFACE
3
4"
[19mm]
!
3
8"
[10mm]
WARNING
USE 1/4” FASTENERS (4X BY OTHERS)
THAT ARE APPROPRIATE FOR USE WITH
YOUR MOUNTING SURFACE
27"
31"
8
2
[73mm] [89mm]
9
32 "
[7mm]
STEP 4. CONNECT LEADER AND JUMPER CABLE
LEADER
JUMPER
« clic
k»
INPUT
CONNECTOR
STEP 5. PUT SEALING CAP ON UNUSED CONNECTOR
PLACE SEALING CAP OVER PANEL MOUNT
CONNECTOR. NO PART REMOVAL REQUIRED.
»
« click
American
Color Code
CE
Color Code
USE
ONCE CABLE IS CONNECTED,
TURN COLLAR 1/4 TURN
CLOCKWISE TO SECURE
INSTALLATION.
(CLICK SOUND WILL OCCUR).
Green
Black
White
Red/Purple
Orange
Yellow/Green
Brown
Blue
Black
Grey
Ground
Live 100-277V
Neutral
0-10V / Data +
0-10V / Data -
STEP 6. CONNECT LEADER CABLE TO J-BOX (BY OTHERS)
WARNING
!
CAUTION
!
1/2” NPT
LIQUID TIGHT
STRAIN RELIEF
(BY OTHERS)
WARNING
SEPARATION OF FIELD INSTALLED POWER LIMITED
CIRCUIT (DIMMING/CONTROL) WIRING FROM THE
BRANCH CIRCUIT WIRING IN THE OUTLET BOX ARE TO
BE MADE IN ACCORDANCE WITH LOCAL AND/OR
NATIONAL ELECTRICAL INSTALLATION CODES.
CAUTION
ENGAGE AND TURN COLLAR 1/4 TURN
CLOCKWISE TO SECURE END CAP INSTALLATION.
(CLICK SOUND WILL OCCUR).
!
WARNING
DISCONNECT POWER BEFORE INSTALLING OR
SERVICING TO AVOID ELECTRICAL SHOCK.
1 SEALING END CAP PROVIDED WITH EACH LEADER CABLE
STEP 7. SEAL JUNCTION BOX
V
RT
sil
ico
ne
! WARNING
FOR WET LOCATION INSTALLATIONS, USE
WEATHERPROOF JUNCTION BOXES AND
SEAL ALL POSSIBLE WATER ENTRY POINTS
AND COVERS USING RTV SILICONE.
(SEALING COMPOUND AND JUNCTION
BOXES BY OTHERS)
DMX/Data Cable Specification
DMX Cable from Controller to CBX and CBX to CBX shall adhere to ANSI E1.11 – 2008 (r2013) – Entertainment Technology –
USITT DMX512-A, Asynchronous Serial Digital Data Transmission Standard for Controlling Lighting Equipment and Accessories. At
minimum DMX Cable shall be 1-Pair (24 AWG, 7x32 Stranding)Twisted (minimum of 4.8 twists/foot), Shielded, minimum of 100
ohms Impedance, and <25 pF/ft. Capacitance.
Combined Power & Data Cable Specification
Fixture cabling from CBX to Fixtures shall be installed per NEC and Local Codes. All cables shall be SOOW style cables with
minimum of 16 AWG annealed stranded bare copper per ASTM B-174 with a minimum temperature range of -40°C to +90°C.
All conductor standing must be a minimum of 26/30 and capable of handling 13 amps. Cable must be water resistant, UL Listed
and CSA certified for indoor and outdoor use. Must be Ozone-sunlight (UV) and weather resistant.
TYPICAL ETE INSTALLATION
1"
MINIMUM
4
[7mm] SPACING
NOTICE
4 1" MINIMUM COIL
TOP VIEW
2
DIMENSION
[115mm]
TYPICAL SAM INSTALLATION
TYPICAL UMAS INSTALLATION
TYPICAL WAM INSTALLATION
TYPICAL UMP INSTALLATION
RECORD THE LOCATION OF EACH
FIXTURE BY SERIAL NUMBER TO
PREPARE FOR THE COMMISSIONING
PROCESS (DMX/RDM).
bin™, a proprietary binning method, guarantees color temperature consistency within a 3-step MacAdam ellipse.
™
Combine lumentranslator with Lumentalk-enabled luminaires housing Lumenpulse's proprietary lumenear control card to build your Lumentalk system.
p.2/2
07/DE/2015
S.Ayite - Rev.4
Lumenpulse, 1751 Richardson, Suite 1505, Montreal (Quebec) Canada H3K 1G6 1.877.937.3003 P. 514.937.3003 F. 514.937.6289
[email protected] www.lumenpulse.com
Copyright © Lumenpulse 2015
Confidential and proprietary
Lumenpulse reserves the right to make changes to this product and related instructions at any time without prior notice
and such changes shall be effective immediately. See www.lumenpulse.com/support/downloads for current data and instructions.