B C .... ...... Actuators for heating, ventilation, air-conditioning ..... . w o...... ❏ ne plement t - 970626 - E p 12 ❏ su aces 2. A l rep at004707 ❏ ✗ 2. A12 / KM>LM-1 / E OEM at001707 LM LM... types superseding KM... types M L at005707 M K B C KM – to – LM Substitution Table y iar xil u A h itc sw KM... types Previous X X X KM24 X X X KM24-3 X X X KM24 with K1 X X X KM24-3 with K1 X X X X LM... types New LM24-F Note running time ! LM24 Note running time ! KMU24-3 No substitute LM.. = KMU24-3 with ZH LM24 with ZH-LM Note running time ! KM220 LM230-F X X X X X X X KM220-S1 X KM220 with K1 X X X X KM220-S1 with K1 LM230 LM230-S X X KMU220 No substitute X X KMU220 with ZH LM230 with ZH-LM Not substituted at the moment ! X X KMU24-V X X KM24-V X X X X X X X X X X X X X KM24-SR X X X KM24-SL X X X KM24-SL with K2 X X X KM24-SR with K2 on round spindles < 35 mm long KM24-PI KM24-PI with K1 KM...... with K1 or K2 LM24-SR-F Control LM24-SR (-F) with DC 0...10V LM24-SR (0...20 V phasecut not possible) LM... with ZA-LM Dimensions ZA-LM and mounting instructions, see pages 6 + 7 or < 35mm LM...-F with K5 ab055807 Note: Wiring modifications KM 2 90° No direct substitute ! Ask for advice if same function required. Special case: LM replacing KM: LM.. = KM24-SH KM24-SH with K1 X 90° LM230-FS X X X Remarks ab055807 pe m Da Spindle-clamp C Open/Close 220 V 24 V Po l ro t on 8 mm form-fit su Modulating r we ot rr n io at y l pp LM see pp. 9 and 10. Mounting instructions, see page 8 B C Contents Dimensions KM... and LM... types Spindle clamp versions 4 Form-fit versions 5 Spindle extension for short spindles ZA-LM Dimensions 6 Mounting on square spindles 8 x 8 mm 6 Mounting on round spindles with K1/K5 7 Mounting on round spindles with K2 7 Mounting instructions LM...-F with K5 Round spindles < 35 mm 8 Wiring modifications KM > LM Open/Close types 9 Modulating types 10 3 B C Dimensions KM... and LM... types (spindle clamp versions) KM.... actuators, modulating KM24, KM24-3, KM220(-S1) .... KM24-SR, KM24-SL 65 K1 21 8...12 8...12 38 82.5 38 4.5 4.5 64 64 82.5 K2 120.5 135 ad007807 120.5 135 ad008807 21 57 KM.... actuators, Open/Close 33.5 59 LM... actuators, Open/Close and modulating min. 35mm 116.2 6...16 94.1 82.5 22.1 1 4 ad009807 5.2 66.2 0 Note: Hinweis: LM24-SR adjustable LM24-SRwithout ohne verstellbare mechanical stops. mechanische Anschläge Subject to technical changes / 12.98 B C Dimensions KM... and LM... types (form-fit versions) KM.... actuators, modulating KM24, KM24-3, KM220(-S1), .... KM24-SR, KM24-SL 57 65 KM.... actuators, Open/Close 87 38 87 38 8 4.5 4.5 64 64 8 125 135 ad011807 ad010807 125 135 33.5 59 LM...-F actuators, Open/Close and modulating 105 33 147.8 94.1 Hinweis: LM24-SR-F ohne verstellbare mechanische Anschläge 22.1 8 1 ad012807 5.2 5.2 66.2 0 Subject to technical changes / 12.98 Note: LM24-SR-F without adjustable mechanical stops. 5 B C Spindle extension for short spindles ZA-LM Dimensions ZA-LM 50 27 23 ad017807 8 + +0 0. .2 1 M4 0 16 -0.2 8 +0.2 +0.1 45° 5 1. Mounting on short square spindles 8 x 8 mm ZA-LM 8x 8mm am010807 <35mm 6 Subject to technical changes / 12.98 B C Spindle extension for short spindles ZA-LM 2. Mounting on short round spindles with K1 or K5 ZA-LM K1,K5 <35mm am011807 8...12 3. Mounting on short round spindles with K2 ZA-LM K2 <35mm am012807 8...12 Subject to technical changes / 12.98 7 Mounting instructions LM...-F with K5 for round spindles < 35 mm long B C am005707 Attention! Do not use the antirotation strap from the KM actuator! (insufficient stability) Note : If LM... actuators are mounted on round spindles less than 35 mm long, it is important to: 1. use the LM...-F form-fit version 2. use the K5 spindle clamp adapter The K5 comes with: • Spindle clamp adapter • LM antirotation strap 8 Subject to technical changes / 12.98 B C Wiring modifications KM LM (Open/Close types) Wiring modifications KM24 ---> LM24 ~ T a aw054810 Connect via safety isolating transformer ! Fit branching box 1 Cut here 3 T 2 3 Rotation a 1 2 ~~ AC 24V KM24 - + + a F u n c t i o n Reversing Reversing switch L switch R b Reversing switch L Reversing switch R OFF OFF LM24 Wiring modifications KM24-3 ---> LM24 ! Connect via safety isolating transformer ~ b T a aw055810 AC 24V Fit branching box F u n c t i o n Rotation Cut here 1 2 3 OFF KM24-3 1 2 T b ~~ a - a 3 LM24 + + AC 220 V To isolate from the main power supply, the system must incorporate a device which disconnects the phase conductors (with at least a 3 mm contact gap). N L1 a Fit branching box 1 cut here a 1 2 aw056810 Wiring modifications KM220 ---> LM230 3 2 3 Rotation KM220 a F u n c t i o n Reversing Reversing switch L switch R a F u n c t i o n Reversing Reversing switch L switch R LM230 Wiring diagram KM220-S1 ---> LM230-S AC 220 V N L1 aw057810 To isolate from the main power supply, the system must incorporate a device which disconnects the phase conductors (with at least a 3 mm contact gap). System control a Fit branching box 1 Cut here a 1 2 3 4 b 3 S1 S2 S3 Rotation KM220-S1 • Switch b SPST closes when the actuator has reached an angle of rotation of 85° (factory set). By resetting of a screw, this switching point ist adjustable between 10...70°. Subject to technical changes / 12.98 2 0...100% LM230-S • The switch closes S1-S3 when the actuator reaches the preset position 0...100% 9 Wiring modifications KM B C LM (modulating types) Wiring modifications KM24-SR ---> LM24-SR (Reversing switch at position L) Connect via safety isolating transformer ! aw058810 AC 24V ~ T Y 0...10 V DC (from controller) Fit branching box 2 3 4 KM24-SR Y+ Y- Closed (Y = 0 V) 2 T ~ 1 1 ~ (Y = 10 V) Open Cut here - + 3 5 Y U LM24-SR Reversing switch L Y=0 (Y = 10 V) Open Closed (Y = 0 V) T Wiring modifications KM24-SL ---> LM24-SR (Reversing switch at position R) ! Connect via safety isolating transformer aw059810 AC 24V ~ T Y 0...10 V DC (from controller) Fit branching box ~ T 10 2 3 4 Y+ Y- KM24-SL 2 Closed T 1 1 (Y = 0 V) - ~ Cut here Open (Y = 10 V) + 3 5 Y U LM24-SR Reversing switch R Y=0 Open (Y = 10 V) Closed (Y = 0 V) Subject to technical changes / 12.98
© Copyright 2026 Paperzz