Paperless Recording System PAPERLESS RECORDER (12.1-inch touch panel) MODEL 75ET MODEL & SUFFIX CODE SELECTION 75ET–M2–R/0002❑ MODEL POWER INPUT R : 24V DC APPLICATION /0002 : Paperless Recorder OPTIONS /A : 32 MB CompactFlash Card /B : 128 MB CompactFlash Card /C : 256 MB CompactFlash Card A CF Card is required to start up the 75ET. If no option code is specified when ordering, the product will be shipped without CF Card. ORDERING INFORMATION Specify code number. (e.g. 75ET-M2-R/0002/A) PACKAGE INCLUDES... •Paperles Recorder Software CD (model: CHARTLSP) •Installation Fasteners RELATED PRODUCTS •Panel Mount Adaptor •PC Recorder I/O Modules (model: A-75) (model: R1M Series) DATA INTERFACE RS-232C: COM1 (9-pin D-sub connector, male) Network: Ethernet I/F Memory card: CF Card; 1 slot Recommended CF Card Manufacturer: Renesas Technology Corporation Capacity: 32 to 512 MB Model No.: HB28D032C8H (32 MB) HB28BxxxC8H (64 to 512 MB) Serial: DISCONTINUED MODEL Replaced with Model 75ET/0003 Functions & Features • Digital recording system replacing the conventional chart recorders • User-friendly screen design transferred from conventional recorders • Data exported to the host PC via Ethernet Typical Applications • System startup data logging, in combination with the R1M-GH2 (voltage and T/C inputs) INSTALLATION Power input: Operational voltage range 24V DC ±20%, ripple 10% p-p max., max. 50W The CF Card may be destroyed if the power supply is removed during recording. Take protective measures against power failure. Operating temperature: 0 to 50°C (32 to 122°F) The screen contrast and other characteristics may deteriorate temporarily if the 75ET operates for a long time period in an ambient higher than 40°C (104°F). They will recover to normal in lower temperatures. Operating humidity: 30 to 85% RH (non-condensing) Dimensions: W317×H243×D58 mm (12.48"×9.57"×2.28") Weight: 3 kg (6.6 lbs) xxx = Memory capacity. e.g. HB28B064C8H for 64 MB. P. 1 / 7 ES-7354-0002 Rev.10 75ET TOUCH PANEL SPECIFICATIONS OS CPU Memory Display Type Colors Windows CE V3.0 SH4, 200 MHz Main memory 32 MB TFT Color LCD (12.1-inch SVGA) Max. 64k colors (among 16,700k colors) Backlight CCFL (replaceable) Resolution 800 x 600 pixels Dot pitch 0.3075 x 0.3075 mm Effective display area 246 x 184.5 mm Brightness control 4 levels Touch Panel Resolution 1024 x 1024 Type Resistive film (analog) Ethernet Communication IP address 192.168.0.1 (factory setting) PERFORMANCE Permissible power interruption: 10 millisec. Insulation resistance: ≥10MΩ with 500V DC Dielectric strength: 1000V AC @1 minute (DC power input to FG) STANDARDS & APPROVAL CE conformity: EMC EN55011, Group 1, Class A EN61000-6-2 CONNECTION DIAGRAM CF CARD SLOT 10BASE-T MODULAR JACK + POWER – D-SUB CONNECTOR ■RS-232C INTERFACE RS-232C GROUND FG 5 9 1 6 ABBR. PIN NO. EXPLANATION OF FUNCTION BB (RD) BA (SD) 1 2 3 Not Used. Received Data Transmitted Data CD (ER) AB (SG) CF (CD) 4 5 6 DTE Ready Signal Common Received Line Signal Detector CA (RS) CB (CS) 7 8 9 Request to Send Clear to Send Do Not Connect. SYSTEM REQUIREMENTS PROVIDED BY THE USER ■HARDWARE ENVIRONEMNTS FOR PC RECORDER SOFTWARE MSR128-V4 IBM PC/AT or compatible Microsoft Windows 2000 or Windows XP SP1, SP2 Pentium III 800 MHz or higher 1024 by 768 pixels or better resolution 65000 colors (16 bits) 2 MB minimum; 4 MB recommended 128 MB minimum; 256 MB recommended for Windows XP Use an internal hard disk. *1 Max. approx. 100 MB required per day. Use a printer for Windows. The programs use Standard System Fonts used in Windows. Use a printer driver for Standard System Fonts. CD-ROM drive Used when installing the software program. Card reader drive Used when reading data from Compact Flash Card Communication port RS-232C port (COM1 through COM5) supported by Windows, LAN card *1. External (e.g. SCSI) devices may impair appropriate performance. PC Operating system CPU Screen area Display color Video memory Main memory Hard disk area Printer Specifications subject to change without notice. P. 2 / 7 ES-7354-0002 Rev.10 COMPONENT IDENTIFICATIONS ■LEFT SIDE VIEW ■FRONT VIEW Touch Panel Switching screens, controls Status Indicator LED* Green: Power ON/Normal (Red to Green at startup) Orange: Backlight failure Red: System error *Located behind the panel mount adaptor (if used). ■REAR VIEW Power Terminals CF Card Slot CompactFlash Card interface ■BOTTOM VIEW Serial Interface (COM1, COM2) RS-232C connector (COM2 unused) 10BASE-T Modular Jack Unidentified connectors and sockets are unused. Ethernet interface P. 3 / 7 ES-7354-0002 Rev.10 75ET 75ET SOFTWARE FUNCTIONS ■NUMBER OF INPUT CHANNELS Max. 128 points from PC Recorder Input Module (R1M/ R2M/RZMS Series). ■I/O MODULES Model No. R1M-GH2 R1MS-GH3 R1M-J3 R1M-A1 R1M-D1 R1M-P4 R2M-2H3 R2M-2G3 RZMS-U9 R5-NM1 I/O Type DC voltage/thermocouple input RTD input Discrete input, totalized pulse input Discrete output Totalized pulse input, discrete input/output Thermocouple input DC voltage input Universal (DC/TC/RTD/Pot) input DC voltage input (R5-SV), DC current input (R5-SS), 4 – 20mA input with excitation (R5DS), Thermocouple input (R5-TS), RTD input (R5-RS), Discrete input (R5-DA), Discrete output (R5-DC)* *Discrete Output Modules must be mounted between Slot No.1 and No.8. No.9 and higher number slots of R5-BS09 (9-position base) or R5-BS16 (16-position base) cannot be used. ■SAMPLING RATE 0.5*, 1, 2, 5, 10 seconds, 1, 10 minutes *4 pens per screen ■DATA STORING METHOD Normal: Recording is manually initiated and stopped. Data is continuously stored while the recording is on. Auto: Recording is automatically initiated and stopped at a predefined time. Event recording: The 75ET detects an external event by trigger signal, and stores preset number of samples before and after the moment of event. Remote trigger: Data is automatically recorded while the external trigger condition (input) is true. ■DATA DISPLAY FUNCTIONS •Record View: Shows data stored in real time. Display rate: 0.5 sec. or 2 sec.** Chart speed: High, Middle**, Low**and Very Low** Chart direction: Perpendicular or horizontal Number of display views: Three (3) Pen thickness: Normal and wide Digital indicator: Shows momentary value. Linear and square root scale **12 pens per screen •Retrieve View: Shows data stored in the CF Card. Number of display views: Three (3) Time index serach: Scroll or Specify a specific time index. •Settings View ■OTHER FUNCTIONS Alarm output: When the input signal is out of a predetermined range, an alarm information is provided on the display and a contact output can be provide at a discrete output module. Ethernet communication: Transmits data of specific channels stored in real time to a host PC installed with the PC Recorder Software Model MSR128V4. ■PAPERLESS RECORDER SOFTWARE PACKAGE (model: CHARTLSP) •PC Recorder Software (model: MSR128-V4) The 75ET can be connected to the host PC via Ethernet. Data can be stored in real time on the MSR128-V4. •PC Configurator Software (model: 7xETBLD) Various parameters for the 75ET can be configured on the PC. Parameter setting can be downloaded via Ethernet to the 75ET. Used also to convert the data stored in the CF Card into a CSV file. ■DATA STORAGE CompactFlash (CF) Card Specifications subject to change without notice. P. 4 / 7 ES-7354-0002 Rev.10 EXTERNAL DIMENSIONS mm (inch) ■75ET 317 (12.48) 8 (.31) 50 (1.97) 227 (8.94) 184.5 (7.26) (screen area) 243 (9.57) 246 (9.59) (screen area) P. 5 / 7 ES-7354-0002 Rev.10 75ET EXTERNAL DIMENSIONS mm (inch) ■A-75 PANEL MOUNT ADAPTOR ■ SIDE VIEW 288 (11.34) INSTALLATION FASTENER ADAPTOR PLATE B 2 (.08) 227 (8.94) (75ET) 288 (11.34) 281 (11.06) (panel cutout) 281 (11.06) (panel cutout) 305 (12.01) ■ FRONT VIEW 61 (2.40) ■ REAR VIEW (rear side) 243 (9.57) (75ET) 317 (12.48) (75ET) Specifications subject to change without notice. P. 6 / 7 ES-7354-0002 Rev.10 MOUNTING REQUIREMENTS mm ■PANEL CUTOUT ■A-75 ADAPTOR PANEL CUTOUT 281 +2 0 281 +2 0 227.5 +1 0 301.5 +1 0 Panel thickness: 1.6 – 10.0 mm 4–R3 max. Panel thickness: 1.6 – 6.0 mm The A-75 panel cutout conforms to DIN 43700. For each maintenance, operation and sufficient ventilation, at the minimum of 100 mm must be observed between the 75ET unit and adjacent structures or equipment. SYSTEM CONFIGURATION EXAMPLES ■R1M SERIES Paperless Recorder (model: 75ET) Ethernet RS-232C Paperless Recorder (model: 75ET) PC Recorder (model: R1M-GH) CONFI G B RATE 34 90 5 678 RUN ERR.1 ERR.2 RS-232C/RS-485 Converter (model: R2K-1) 12 RS-485 PC Recorder (model: R1M-GH) PC Recorder (model: R1M-A1) PC Recorder (model: R1M-D1) When the cable distance between the 75ET and the R1Ms is long, insert an RS-232C/RS-485 Converter for isolation. P. 7 / 7 ES-7354-0002 Rev.10
© Copyright 2026 Paperzz