SPECIFICATION SHEET Remote Reading Interface for Water Meters DR3 J © • Indoor/Outdoor use • Electronics are fully potted • Easy to operate • Five (5) year warranty • Operating temperature range: -20° F to + 150° F • Physical dimensions: 4” x 2” x 2” • Moisture resistant • High capacity, sealed battery •m •16x2 alpha-numeric display • Terminal block meter connection (no splicing required) Overview Digi-Read is the latest in remote reading technology, featuring a rugged design and ease of use operation. Digi-Read is designed to operate in an indoor or outdoor environment. The electronics and battery are fully potted, making the unit moisture resistant. The display is also sealed to protect the reading visibility. Digi-Read is activated (read) utilizing the touch-sensitive pad next to the display. Connectivity Digi-Read is designed to interface to most popular pulse-type or encoded water, gas, and electric meter units. Single Reed Switch Digi-Read Either wire Either wire Ch.A Generator Digi-Read Positive Negative Ch.A GND Neptune Encoder Digi-Read Black Red Green Control Ch. B GND To Connect Wire at the Meter Sensus Encoder On the Neptune meter register there are three terminal screws to make the Red three wire connection. They are located under the black plastic terminal cover Green that is on the edge of the dial face.* Pull up on the outside edge of the cover Black to remove it. Each terminal has a letter that matches one of the leads from the 3 conductor wire, (B) for Black, (G) for Green and (R) for Red.** Connect each lead to the color matching terminal screw and snap the terminal screw cover back in place. GND Diai-Read Control Ch. B GND To Connect Wire at the DR3 Remote The Black lead connects to the “Control” terminal screw. The Red lead connects to the “Ch. B” terminal screw. The Green lead connects to the “GND” terminal screw. *lf you purchased a remote for an existing Neptune meter it must be equipped with either a ProRead or E-Coder register that has the three terminal screws to wire to the remote. If you do not have the terminal screws, that means you have a direct read register and you will need to purchase a replacement register to install on your meter. **lf you did not purchase the wire with the remote and you plan on using your own wire you will need to make sure it is three conductor and a minimum of 22 gauge. The color of your leads may not match the color scheme in these instructions so you will need to take care in matching your color leads with the corresponding terminals on the meter and at the remote. (continued on back) SPECIFICATION SHEET Page 2 DR3 Remote Reading Interface for Water Meters To Activate the LCD Display to Get a Reading There is a “D” to the left of the LCD display, touch your finger to the “D” and hold it there for a few seconds. The LCD display will activate and show the reading, then after a few moments it will turn off to preserve battery life. Resolution The reading on the DR3 digital remote does not display the “fixed zeros” that are printed to the right of the number wheels on the dials of many meters. To determine your true reading, you will need to add zeros to your DR3 reading as necessary. The fixed zeros are like multipliers of 10. Identify how many zeros are printed on your meter, there may be any number of them from none to three. You will need to include these every time you take a reading from the DR3. For example: If your meter dial face is showing 0003450 (bold zero is a fixed zero, all the other digits are moving wheels) the total would be 3450. The reading on the DR3 remote will display 000345, not showing the fixed zero. This is why it is important to include the fixed zeros every time you view the reading on the DR3 remote. The chart below is a guideline for Neptune meters and fixed zeros Meter Size & Type - Gallons 5/8” — 1” T-10 Zeros To Add 1 1-1/2” & 2” T-10 2 1-1/2” -4” Turbine 2 6” -12” Turbine 3 Meter Size & Type - Cubic Feet Zeros To Add 5/8”- 1” T-10 None 1-1/2” -2” T-10 1 1-1/2” -4” Turbine 1 6” -12” Turbine 2
© Copyright 2025 Paperzz