RURAL ZONING DISTRICT – SITE PLAN REQUIREMENTS FOR RESIDENTIAL DEVELOPMENT Owner’s name, preparer’s name, preferred scale (1”=20’), north arrow, and date of preparation. Plans are not to exceed 24” x 36” in size. Name, signature, and stamp of architect, engineer, or surveyor may be required, depending on the type of application. A vicinity map indicating the location of the site relative to the major roads in the area. Dimensioned boundaries of subject parcel(s), gross and net lot area, City/County boundary limits, and all right-of-way easements of adjacent streets (including width and whether County maintained or Not County maintained). Location of existing and proposed improvements, including all Location and width of all easements for water, sewage, storm drainage, utilities or other purposes. Accurate contour lines showing topography at reasonable intervals on lands with slope greater than five percent. Existing drainage patterns and drainage patterns as a result of the proposed improvements. Show areas of flooding (100-year flood). Location, common name, diameter and number of trees to be removed or located near improvements, measured 4.5 feet above grade. buildings, decks, swimming pools, arbors, landings, porches, retaining walls (indicate top and bottom elevation of wall), fences, power poles, water tanks, bridges, etc. Show dimensions, required front-, rear-, and side-yard setbacks, and distances to property lines and other buildings. Unusual topographic features including watercourses, swales, Location of existing and/or proposed septic systems and wells. Call Proposed earthwork quantities for grading located outside of the (408) 918-3400 or visit the Department of Environmental Health’s website at www.ehinfo.org for more information. building footprint. Provide the breakdown of total grading quantities (cut/fill, vertical height of cut or fill) for the various improvements. Calculation of existing and proposed floor area (as defined in ditches, culverts, creeks, streams, etc. Show setback from top and centerline of bank (see Water Collaborative Handout). Any known soil or geologic hazard areas (faults, landslides, etc.). Chapter 1.30 of the County Zoning Ordinance). See Floor Area Calculation pamphlet for more information. If proposed access to the property is from a private road, show Existing and proposed access and parking areas including private For lots in HS zoning districts, the site plan must outline the streets, driveways, carports and garages. Demonstrate how proposed improvements comply with the Fire Marshal Office (FMO) and Land Development Engineering’s (LDE) access standards. Call (408) 299-5760 for information regarding FMO standards. Visit www.sccbuilding.org for LDE standards. proposed developed area and show topography using contour lines that represent five-foot intervals in elevation. Average slope computations must be shown on the site plan along with the certification stamp and signature by a registered civil engineer or licensed land surveyor (see separate Building Site Approval handout for details). how existing or proposed road meets FMO/LDE road standards. July 2008 SITE 10”-15” Sycamores 24”-48” Live Oaks SEPTIC FIELD VICINITY MAP 10’ min. Johnson 10” Sycamore 20” Live Oak 30’ Bldg Setback Line (Typ.) 1500 gal. tank 15” Sycamores 6’ min. (N) Hydrant TOW 379.0 BOW 376.0 Top of Bank 20” Live Oak 10” Sycamore (N) Well 15” Sycamore 100’ radius 24” Live Oak (N) 2-story 40’ Min Residence w/covered porch FF 384.00 24” Live Oak PAD 380.00 (N) Bridge Top of Bank (N) 3-car Garage and Barn PAD 380.00 48’ Min (E) Residence to be demolished 20” Live Oak 10’ min. Winding Way (NOT COUNTY MAINTAINED) Trees to be Removed 1 - 24” Coast Live Oak, located at driveway TOW 376.0 BOW 372.0 10” Sycamores Winding Way Creek Nguyen 15” Sycamore 30’ Bldg Setback Line (Typ.) Grading Quantities (Cubic Yds) Cut Fill Height House 0 150 4’ Driveway 500 500 4’ Site Plan for Mr. and Mrs. Smith 12345 Winding Way, My City Lot Size (Gross): 20.4 acres Zoning: AR (N) 2-story Residence: 4,250 sq. ft. Hernandez (N) 2-story Garage & Barn: 1,450 sq. ft. (N) Shed Structure: 600 sq. ft. (N) Covered Porch: 1,200 sq. ft. (2) 5,000-gallon water tanks on pad (N) Driveway: 3,500 sq. ft. ABC ENGINEERING SERVICES 100 STATE STREET ANYTOWN, CA 95000 SAMPLE SITE PLAN – RURAL ZONING DISTRICT For Residential Development 20” Live Oaks CL CL EXISTING PAVEMENT north Scale: 1” = 20’ SHEET 1 OF 1 URBAN ZONING DISTRICT – SITE PLAN REQUIREMENTS FOR RESIDENTIAL DEVELOPMENT Owner’s name, preparer’s name, preferred scale (1”=20’), north Accurate contour lines showing topography at reasonable arrow, and date of preparation. Plans are not to exceed 24” x 36” in size. Name, signature, and stamp of architect, engineer, or surveyor may be required, depending on the type of application. Unusual topographic features including watercourses, swales, A vicinity map indicating the location of the site relative to the ditches, culverts, creeks, streams, etc. Show setback from top and centerline of bank (see Water Collaborative Handout). principal roads in the area. Dimensioned boundaries of subject parcel(s), gross and net lot area, and all right-of-way easements of adjacent streets (including width and whether County maintained or Not County maintained). Location of existing and proposed improvements, including all buildings, decks, swimming pools, arbors, landings, porches, retaining walls, fences, etc. Show dimensions, required front-, rear-, and side-yard setbacks, and distances to property lines and other buildings. Calculation of existing and proposed floor area (as defined in Chapter 1.30 of the County Zoning Ordinance). See Floor Area Calculation pamphlet for more information. Roof plan of existing and proposed improvements and dimensions of all rooflines. Existing and proposed access and parking areas including private streets, driveways, carports and garages. If driveway is longer than 150 feet, demonstrate that it meets the Fire Marshal Office’s (FMO) standards. Call (408) 299-5760 or visit the FMO website at http://firemarshal.sccgov.org for more information. Location and width of all easements for water, sewage, storm intervals on lands with slope greater than five percent. Location, common name, diameter and number of trees to be removed or located near improvements, measured 4.5 feet above grade. Proposed earthwork quantities for grading located outside of the building footprint. Provide the breakdown of total grading quantities (cut/fill, vertical height of cut or fill) for the various improvements. Existing drainage patterns and drainage patterns as a result of improvements. If on septic, show proposed septic system. Call (408) 918-3400 or visit the Department of Environmental Health’s website at www.ehinfo.org for more information. For lots in RHS and R1E zoning districts, the site plan must outline the proposed developed area and show topography using contour lines that represent five-foot intervals in elevation. Average slope computations in the developed area must be shown on the site plan along with certification stamp and signature by a registered civil engineer or licensed land surveyor (see separate Average Slope for Building Site Approval handout for details). drainage, utilities or other purposes. February 2008 PL SITE 10’ Utility Easement Proposed 225 sq. ft. Storage Shed 18” Roof overhang VICINITY MAP 18’-6” separation betw. buildings Proposed 500 sq. ft. Addition 10’-0” side setback Existing Drainage Flow 3’-0” side setback for accessory structures APN: 123-12-123 Address: 1234 My Street, My City Roof overhang (24” typ.) Lot Size (Gross): 9800 sq. ft. 140.0’ 140.0’ Lot Size (Net): 9800 sq. ft. Zoning: R1-10 (E) Main Res. Floor Area: 1,500 sq. ft. Proposed Main Addition: 750 sq. ft. Proposed Accessory Structure: 225 sq. ft. Existing 1-Story Residence w/Attached Garage Total Main Res. Floor Area: 2,250 sq. ft. Rear Yard Area (28’x70’): 1,960 sq. ft. 30% Rear Yard Coverage Allowed: 588 sq. ft. Proposed Rear Yard Coverage: (15’x15’) 225 sq. ft. PL CL NO GRADING PROPOSED 6’ tall (E) fence Revisions Driveway 70.0’ My Street (County Maintained) 25’ 8” Cedar 25’ front yard Property Line Walkway Proposed 250 sq. ft. Porch Addition ABC ENGINEERING SERVICES 100 STATE STREET ANYTOWN, CA 95000 70.0’ 25’ rear yard PL Property Corner (E) Iron Pipe Site Plan for Mr. and Mrs. Smith 1234 My Street, My City SAMPLE SITE PLAN – URBAN ZONING DISTRICT For Residential Development PL north CL Scale: 1” = 20’ SHEET 1 OF 1
© Copyright 2026 Paperzz