INDUSTRIES AMERICAN COOLAIR CORPORATION Centrifugal Upblast Power Roof Ventilators TYPE UBCA - BELT DRIVE TYPE UDCA - DIRECT DRIVE TABLE OF CONTENTS UBCA BELT DRIVE FANS UBCA Sizes 06 to 44 Flow rates from 229 to 29,002 CFM and 2” Static Pressure UDCA • • • • • • • • • • • • • • • • Dimensional Data ............................…...........… 3 Fan Description ………….............................….. 4 Alternate Construction …............................….. 5 Performance - 06 ...........................................… 6 Performance - 08 .............................................. 7 Performance - 10 .............................................. 8 Performance - 12 ...........................................… 9 Performance - 13 .............................................. 10 Performance - 15 .............................................. 11 Performance - 16 ..........................................…. 12 Performance - 18 .............................................. 13 Performance - 20 .............................................. 14 Performance - 24 .............................................. 15 Performance - 30 .............................................. 16 Performance - 36 .............................................. 17 Performance - 44 .............................................. 18 DIRECT DRIVE FANS UDCA • • • • • Dimensional Data ............................................. Fan Description ................................................ Performance - 12 ............……........................... Performance - 13 ............……........................... Performance - 15.............……........................... 3 19 20 20 21 Sizes 12 to 15 Flow rates from 619 to 3,032 CFM and 1-1/2” Static Pressure • Installation & Maintenance ........................….. 22 • Options & Accessories …...........................….. 23 • Specification Checklist ..............................….. Back Cover ILG 2 STANDARD FEATURES UBCA and UDCA Units Weather-resistant motor compartment cover of spun aluminum removes easily for access to motor and drive. UBCA UBCA Safety disconnect switch is an available option. Belt drive with adjustable motor pulley for flexibility to match operating requirements. Heavy duty pillow-block ball bearings with cast iron housing are self-aligning and relubricable. Hinged motor bracket with tensioning bolt(s) facilitates maintenance of belt tension. UL Listed for Standard 705 and 762. UDCA UDCA Factory-wired disconnect device for standard motors. Direct-drive assembly reduces maintenance and operating costs. Out-of-airstream open motors are isolated for protection from exhaust airstream. Overlapping wheel and deep-spun venturi minimize noise and air turbulence, increasing efficiency. UL Listed for Standard 705 and 762. UBCA and UDCA Ventilator, Roof Curb, and Damper Dimensions B DIA. Built-in drain removes grease and water from fan housing. C Aluminum centrifugal wheel is a non-overloading, backward inclined design with state-ofthe-art computerized balance. A SQ. I.D. 2” K SQ. H O.D. 1 5/8” 8” STD. HEIGHT Permanently affixed wheel balance weights assure vibration-free operation. Wheel backplate fins cool the motor compartment, extending motor life. AMCA Seal assures certified rating of air and sound performance. D 1 5/8” J I.D. 11/2” THICK INSULATION E SQ. 1” G SQ. Unit UBCA 06-10 UDCA 12-15 UBCA 12-15 UBCA 16, 18 UBCA 20 UBCA 24 UBCA 30 UBCA 36 UBCA 44 Ventilator Dimensions A B C D 18 23 3/4 22 11 1/4 26 29 3/8 18 1/8 19 1/4 26 29 3/8 24 1/2 19 1/4 30 35 3/8 26 1/2 21 5/8 34 43 3/8 29 7/8 25 1/2 34 43 3/8 34 1/4 25 1/2 40 51 1/4 38 1/2 29 1/2 46 62 5/8 45 7/8 37 1/2 56 73 51 1/8 40 Roof Curb and Damper Dimensions E G H J K 12 1/2 11 1/4 16 1/2 13 1/4 24 1/2 20 3/4 19 1/4 24 1/2 21 1/4 32 1/2 20 3/4 19 1/4 24 1/2 21 1/4 32 1/2 24 3/4 23 1/4 28 1/2 25 1/4 36 1/2 28 3/4 27 1/4 32 1/2 29 1/4 40 1/2 28 3/4 27 1/4 32 1/2 29 1/4 40 1/2 34 3/4 33 1/4 38 1/2 35 1/4 46 1/2 40 3/4 39 1/4 44 1/2 41 1/4 52 1/2 50 3/4 49 1/4 54 1/2 51 1/4 62 1/2 Dimensions in inches 3 ILG UBCA Belt Drive Centrifugal Upblast Power Roof Ventilators Applications The UBCA units are quiet, dependable upblast power roof ventilators for the exhaust of grease-laden air from restaurant range hoods, and general ventilation applications where vertical discharge of exhaust air is required. Applications include virtually all types of commercial and institutional kitchens, such as restaurant and cafeteria, fast food, hospital, hotel and motel, bakery, delicatessen, school and military. UBCA units are specified where a roof-mounted location is desired to eliminate interference with other equipment or activities in the building. They permit the direct upward venting of overheated air. The UBCA is listed under UL classification YZHW for Power Roof Ventilators for Restaurant Exhaust Systems. When properly installed, the UBCA also meets the requirements of National Fire Protection Association Standard NFPA 96. These units are particularly recommended for economical and efficient range hood ventilation where continuous operation under severe conditions may cause other power roof ventilators to fail. Construction Construction of UBCA units features heavy gauge steel structural support throughout consisting of steel base, motor compartment disc and support pipes, to maintain support and proper alignment of motor, wheel and drive during shipment, installation and operation. The spun aluminum motor compartment cover provides protection from weather and contaminated air and is easily removable for complete access to motor and drive. UBCA models feature a housing of durable spun aluminum for optimum weather protection. The overlapping deep-spun venturi minimizes air turbulence and increases efficiency. The aluminum centrifugal wheel is a non-overloading, backward-inclined type, selected for low noise levels. Backplate fins draw cool air through the motor compartment. The wheels are computer balanced on state-of-the-art equipment. The UBCA wheel is secured to a machined aluminum hub with a line bore, which eliminates the need for bushings. Drive Mechanism The belt driven UBCA utilizes a standard V-belt drive design with a variable pitch cast iron motor pulley for adjusting fan speed. Drive shaft is turned, ground and polished. Motor support features a hinged motor bracket with belt tensioning bolt(s) for easy field adjustment. Motors The standard motor for UBCA models is open construction, located out of the airstream. Totally enclosed, energy efficient, two-speed and explosion-proof motors may also be available. Motor enclosure may affect UL Listing. All motor brands are recognized and serviced nationwide. Bearings Heavy duty pillow-block ball bearings with cast iron housing are self-aligning and relubricable. ILG 4 UL705 - E39944 UL762 - MH9847 Type UBCA ventilators are UL705 Listed by Underwriters Laboratory Inc. to US and Canadian safety standards. Type UBCA ventilators are UL762 Listed by Underwriters Laboratory Inc. to US safety standards. American Coolair Corporation, ILG Industries certifies that the Type UBCA PRVs shown herein are licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and AMCA Publication 311 and comply with the requirements of the AMCA Certified Ratings Program. Guide Specifications Upblast power roof ventilators shall be of the UBCA centrifugal type as manufactured by ILG Industries of American Coolair Corporation (individual models to be listed in fan schedule). Units shall meet UL Standard 705 or 762 as required and shall bear the AMCA Certified Ratings Seal for air and sound performance. Bottom outer housing and venturi inlet shall be one piece heavy gauge spun aluminum with built-in grease drain. Wheel and venturi shall overlap for efficient operation. Motor compartment cover shall be heavy gauge spun aluminum construction and easily removable for access to motor and drive. Base, motor compartment disc and support pipes shall be heavy gauge steel. Drive mechanism shall incorporate a V-belt drive with cast iron motor pulley. Drive shaft shall be turned, ground and polished. The centrifugal wheel shall be heavy gauge aluminum with backward-inclined, non-overloading blades and be computer balanced. Bearings shall be self-aligning and have fittings for relubrication. Motor shall be open drip-proof construction, NEMA design B with minimum service factor of 1.15. Motor compartment shall be cooled by a forced air ventilation system. Adjustable motor pulley shall be provided to allow for field adjustment and system balance. Motor shall be mounted on an adjustable steel mounting bracket. Motor shall be mounted with the shaft up to allow easy access to the cast iron variable pitch drive pulley. (Safety disconnect switch, epoxy coating, roof curb and other accessories shall be listed in the fan schedule.) Alternate Fan Constructions Heat & Smoke Control High Wind/Miami Dade UBCA models, sizes 1230 may be specified for Heat/Smoke Control (UL Standard 793) UBCA & UDCA models may be specified for High Wind Construction x Heavy-duty galvanized steel impeller and inlet x Engineered and tested to exhaust: x High-velocity impact tested x Static air pressure force tested 500° F air for 4 hours 400° C (752° F) air for 2 hours 1,000° F air for 20 minutes x Florida High Velocity Hurricane Zone compliant x Miami-Dade County Product Control Complies with Florida Building Code High Velocity Hurricane Zone UL793 Type UBCA ventilators are UL793 Listed by Underwriters Laboratory Inc. to US and Canadian safety standards. Miami-Dade County Product Control Approved 5 ILG UBCA06 Performance Data CFM at Static Pressure 0.00 .125 .250 .375 .500 .625 0.75 RPM Range 1.00 1.25 1.50 BHP Sone BHP Sone BHP Sone BHP Sone BHP Sone BHP Sone BHP Sone BHP Sone BHP Sone BHP Sone 375 0.04 6.2 397 0.05 7.0 419 0.06 7.6 441 0.07 8.2 463 0.08 8.9 485 0.10 9.6 507 0.11 10.2 529 0.12 11.0 551 0.14 11.9 573 0.16 12.9 595 0.18 14.0 617 0.20 15.0 639 0.22 16.1 661 0.24 17.2 683 0.27 18.4 336 0.04 5.5 361 0.05 6.3 385 0.06 7.0 409 0.07 7.6 433 0.08 8.3 456 0.10 9.0 479 0.11 9.7 502 0.12 10.4 526 0.14 11.2 549 0.16 12.2 572 0.18 13.3 595 0.20 14.4 618 0.22 15.6 640 0.24 16.7 663 0.27 18.0 290 0.05 5.0 319 0.05 5.8 347 0.06 6.4 373 0.07 7.0 399 0.09 7.6 425 0.10 8.3 450 0.11 9.0 474 0.13 9.7 499 0.14 10.5 523 0.16 11.5 548 0.18 12.6 571 0.20 13.7 595 0.22 14.8 619 0.24 16.0 642 0.27 17.5 Motor HP 1/4 L 1/4 M RPM 1/4 H 1217 255 0.06 5.3 294 0.07 5.9 328 0.08 6.5 360 0.09 7.1 389 0.10 7.8 417 0.11 8.5 444 0.13 9.2 470 0.14 9.9 496 0.16 10.8 522 0.18 11.9 547 0.20 12.9 572 0.22 14.0 596 0.25 15.3 621 0.27 16.8 1288 229 0.07 5.4 264 0.08 6.0 303 0.09 6.6 341 0.10 7.3 376 0.12 8.0 408 0.13 8.7 438 0.15 9.4 466 0.17 10.4 494 0.18 11.3 521 0.20 12.3 547 0.23 13.4 573 0.25 14.6 598 0.27 16.1 1360 1431 1503 1574 1646 359 0.13 8.2 396 0.15 9.0 430 0.17 9.8 462 0.19 10.8 491 0.21 11.8 520 0.23 12.9 547 0.25 14.0 574 0.28 15.5 1717 1789 1861 420 0.19 10.3 455 0.21 11.3 488 0.23 12.4 518 440 0.26 13.4 0.26 12.5 547 479 0.28 15.0 0.29 14.0 1933 2004 2076 2147 2219 Performance shown is for Type A: free inlet, free outlet. Performance ratings do not include the effects of appurtenances (accessories). Power rating (BHP) does not include transmission losses. Bearing losses are included. The sound ratings shown are loudness values in hemispherical sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for installation Type A: free inlet hemispherical sone levels. 6 ALL SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE UBCA08 Performance Data CFM at Static Pressure 0.00 .125 .250 .375 .500 .625 0.75 RPM Range 1.00 1.25 1.50 BHP Sone BHP Sone BHP Sone BHP Sone BHP Sone BHP Sone BHP Sone BHP Sone BHP Sone BHP Sone 519 0.05 6.3 549 0.06 7.1 580 0.07 7.7 610 0.08 8.4 641 0.09 8.9 671 0.10 9.6 702 0.12 10.3 732 0.13 11.0 763 0.15 11.8 794 0.17 12.6 824 0.19 13.6 855 0.21 14.6 885 0.23 15.6 916 0.26 16.8 946 0.28 18.3 476 0.05 5.8 508 0.06 6.6 541 0.07 7.2 574 0.08 7.8 606 0.09 8.5 638 0.10 9.1 670 0.12 9.8 702 0.14 10.5 734 0.15 11.3 766 0.17 12.2 797 0.19 13.1 829 0.21 14.0 860 0.24 15.1 891 0.26 16.3 923 0.29 17.7 428 0.05 5.5 465 0.06 6.3 501 0.07 6.9 536 0.08 7.5 570 0.10 8.2 604 0.11 8.7 638 0.12 9.4 671 0.14 10.1 704 0.16 10.9 737 0.18 11.8 770 0.20 12.7 802 0.22 13.6 835 0.24 14.7 867 0.27 15.8 899 0.29 17.2 362 0.06 5.2 407 0.07 6.1 452 0.08 6.7 492 0.09 7.2 531 0.10 7.9 568 0.12 8.5 604 0.13 9.1 639 0.15 9.8 673 0.16 10.6 708 0.18 11.4 742 0.20 12.3 775 0.23 13.3 809 0.25 14.3 842 0.27 15.4 875 0.30 16.8 RPM Motor HP 1/4 L 1/4 M 1/4 H 1217 339 0.07 5.8 390 0.08 6.4 434 0.09 7.0 480 0.11 7.7 524 0.12 8.3 565 0.14 8.9 604 0.15 9.6 641 0.17 10.4 677 0.19 11.2 713 0.21 12.1 748 0.23 13.0 783 0.26 14.0 817 0.28 15.1 851 0.31 16.5 1288 1360 372 0.09 6.7 424 0.11 7.3 469 0.12 8.0 515 0.14 8.6 559 0.16 9.3 603 0.18 10.1 643 0.20 11.0 682 0.22 11.9 719 0.24 12.8 755 0.27 13.8 790 0.29 14.9 826 0.32 16.3 1431 1503 1574 1646 510 0.16 9.0 555 0.18 9.9 600 0.20 10.7 644 0.22 11.7 685 0.25 12.6 725 0.27 13.6 762 0.30 14.6 799 0.33 16.0 1717 1789 1861 1933 602 0.25 12.0 647 0.28 13.1 692 0.31 14.2 736 659 0.34 15.6 0.34 15.0 2004 2076 2147 2219 Performance shown is for Type A: free inlet, free outlet. Performance ratings do not include the effects of appurtenances (accessories). Power rating (BHP) does not include transmission losses. Bearing losses are included. The sound ratings shown are loudness values in hemispherical sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for installation Type A: free inlet hemispherical sone levels. ALL SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE 7 UBCA10 Performance Data CFM at Static Pressure 0.00 .125 .250 .375 .500 .625 0.75 RPM Range 1.00 1.25 1.50 BHP Sone BHP Sone BHP Sone BHP Sone BHP Sone BHP Sone BHP Sone BHP Sone BHP Sone BHP Sone 697 0.05 7.2 738 0.07 8.0 779 0.08 8.7 820 0.09 9.4 861 0.10 10.1 902 0.12 10.8 943 0.14 11.6 984 0.15 12.3 1025 0.17 13.2 1066 0.20 14.2 1108 0.22 15.3 1148 0.25 16.5 1190 0.27 17.8 640 0.06 6.6 684 0.07 7.4 728 0.08 8.1 772 0.09 8.8 816 0.11 9.5 858 0.12 10.2 902 0.14 11.0 944 0.16 11.8 987 0.18 12.7 1030 0.20 13.6 1073 0.23 14.7 1115 0.25 16.0 1157 0.28 17.3 572 0.06 6.2 622 0.07 7.0 671 0.09 7.7 718 0.10 8.4 765 0.11 9.1 811 0.13 9.8 857 0.15 10.6 902 0.17 11.3 947 0.19 12.3 992 0.21 13.2 1036 0.23 14.3 1079 0.26 15.5 1123 0.29 16.8 498 0.07 5.6 553 0.08 6.5 607 0.09 7.3 659 0.10 8.0 710 0.12 8.7 759 0.14 9.4 808 0.15 10.2 856 0.17 11.0 903 0.19 11.9 950 0.22 12.9 997 0.24 13.9 1042 0.27 15.0 1088 0.30 16.4 Motor HP 1/4 L 1/4 M RPM 1/4 H 1217 1288 1360 595 0.11 7.5 650 0.12 8.3 703 0.14 9.1 756 0.16 9.8 807 0.18 10.6 857 0.20 11.6 906 0.22 12.6 955 0.25 13.5 1003 0.27 14.7 1050 0.30 16.0 1431 1503 645 0.14 8.6 701 0.16 9.4 755 0.18 10.2 808 0.20 11.2 860 0.23 12.2 911 0.25 13.2 961 0.28 14.3 1010 0.31 15.7 1574 1646 1717 757 0.21 10.8 812 0.23 11.8 865 0.26 12.9 917 826 0.28 14.0 0.29 13.1 969 882 0.31 15.3 0.32 14.5 1789 1861 1933 2004 2076 Performance shown is for Type A: free inlet, free outlet. Performance ratings do not include the effects of appurtenances (accessories). Power rating (BHP) does not include transmission losses. Bearing losses are included. The sound ratings shown are loudness values in hemispherical sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for installation Type A: free inlet hemispherical sone levels. 8 ALL SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE UBCA12 Performance Data CFM at Static Pressure 0.00 .125 .250 .375 .500 .750 1.00 1.25 1.50 2.00 BHP Sone BHP Sone BHP Sone BHP Sone BHP Sone BHP Sone BHP Sone BHP Sone BHP Sone BHP Sone 1222 0.10 6.7 1275 0.11 7.4 1329 0.12 8.0 1381 0.14 8.7 1435 0.15 9.5 1487 0.17 10.2 1541 0.19 11.0 1594 0.21 11.9 1647 0.23 12.7 1700 0.26 13.6 1754 0.28 14.4 1806 0.31 15.0 1860 0.34 15.7 1912 0.37 16.5 1966 0 40 17.3 0.40 17 3 2020 0.43 18.1 2072 0.46 18.7 2126 0.50 19.5 2178 0.54 20 2232 0.58 21 2285 0.62 22 2338 0.67 23 1121 0.11 6.6 1178 0.12 7.2 1235 0.13 7.9 1290 0.15 8.6 1347 0.17 9.4 1402 0.19 10.1 1458 0.21 10.9 1515 0.23 11.8 1569 0.25 12.6 1625 0.27 13.5 1681 0.30 14.3 1735 0.32 14.9 1791 0.35 15.6 1845 0.38 16.3 1900 0.42 0 42 17.1 17 1 1955 0.45 17.9 2009 0.48 18.5 2064 0.52 19.3 2118 0.56 20 2173 0.60 21 2228 0.65 22 2282 0.69 23 1024 0.11 6.2 1086 0.13 6.9 1147 0.14 7.5 1206 0.16 8.2 1266 0.18 8.9 1324 0.20 9.7 1382 0.22 10.5 1441 0.24 11.4 1498 0.26 12.3 1555 0.29 13.2 1613 0.31 13.9 1669 0.34 14.6 1726 0.37 15.4 1781 0.40 16.1 1838 0.43 0 43 16.9 16 9 1895 0.47 17.7 1950 0.50 18.3 2006 0.54 19.1 2061 0.58 20 2117 0.62 21 2174 0.67 22 2228 0.71 23 915 0.12 5.8 985 0.13 6.5 1052 0.15 7.1 1117 0.17 7.9 1181 0.18 8.6 1243 0.20 9.4 1306 0.23 10.1 1367 0.25 11.0 1427 0.27 11.9 1487 0.30 12.7 1547 0.32 13.5 1605 0.35 14.2 1663 0.38 15.0 1721 0.41 15.8 1779 0.45 0 45 16.6 16 6 1837 0.48 17.4 1893 0.52 18.1 1951 0.56 18.8 2007 0.60 19.7 2064 0.64 21 2121 0.68 22 2177 0.73 23 781 0.12 5.6 867 0.14 6.2 945 0.15 6.8 1017 0.17 7.4 1088 0.19 8.2 1156 0.21 8.9 1223 0.23 9.7 1289 0.26 10.6 1352 0.28 11.5 1416 0.31 12.3 1479 0.33 13.1 1539 0.36 13.8 1600 0.39 14.7 1660 0.42 15.5 1720 0.46 0 46 16.4 16 4 1780 0.49 17.1 1838 0.53 17.8 1896 0.57 18.6 1954 0.61 19.4 2012 0.65 20 2070 0.70 21 2127 0.75 22 RPM Range Motor HP 1/4 L 1/4 H 1/3 1/2 RPM 3/4 1072 1119 1166 1212 845 0.19 7.7 942 0.22 8.4 1029 0.24 9.0 1110 0.27 9.8 1185 0.29 10.6 1258 0.32 11.5 1329 0.35 12.2 1396 0.38 13.0 1464 0.41 14.0 1529 0.44 14.8 1595 0.48 0 48 15.7 15 7 1659 0.52 16.5 1721 0.55 17.2 1784 0.59 18.0 1845 0.64 18.7 1907 0.68 19.6 1968 0.73 21 2028 0.77 22 1259 1305 1352 1399 955 0.29 10.3 1057 0.32 11.1 1148 0.35 11.7 1230 0.39 12.4 1309 0.42 13.3 1383 0.46 14.2 1456 0.50 0 50 15.0 15 0 1527 0.53 15.9 1594 0.57 16.6 1663 0.61 17.4 1728 0.66 18.1 1794 0.70 18.9 1859 0.75 19.9 1922 0.80 21 1445 1492 1539 990 0.37 12.1 1105 0.42 13.0 1202 0.46 13.8 1292 0.50 0 50 14.6 14 6 1375 0.54 15.3 1453 0.59 16.0 1528 0.63 16.8 1600 0.68 17.5 1672 0.72 18.3 1742 0.77 19.1 1810 0.82 20 1585 1632 1678 1053 0.48 0 48 14.2 14 2 1175 0.53 15.1 1276 0.58 15.8 1369 0.63 16.5 1454 0.68 17.2 1535 0.73 17.9 1613 1253 0.79 18.6 0.75 18.1 1687 1368 0.84 19.5 0.82 19.0 1725 1772 1818 1865 1911 1958 2005 2051 Performance shown is for Type A: free inlet, free outlet. Performance ratings do not include the effects of appurtenances (accessories). Power rating (BHP) does not include transmission losses. Bearing losses are included. The sound ratings shown are loudness values in hemispherical sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for installation Type A: free inlet hemispherical sone levels. ALL SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE 9 UBCA13 Performance Data CFM at Static Pressure 0.00 .125 .250 .375 .500 .750 1.00 1.25 1.50 2.00 BHP Sone BHP Sone BHP Sone BHP Sone BHP Sone BHP Sone BHP Sone BHP Sone BHP Sone BHP Sone 1617 0.16 10.5 1685 0.18 11.5 1752 0.20 12.4 1820 0.23 13.6 1886 0.25 14.4 1954 0.28 15.2 2022 0.31 15.9 2089 0.34 16.6 2157 0.38 17.5 2225 0.41 18.3 2291 0.45 19.1 2359 0.49 20 2425 0.54 21 2493 0.58 22 2561 0 63 23 0.63 1524 0.17 10.1 1596 0.19 11.1 1665 0.22 12.1 1736 0.24 13.3 1805 0.27 14.1 1876 0.30 14.9 1946 0.33 15.6 2015 0.36 16.4 2085 0.39 17.2 2155 0.43 18.0 2224 0.47 18.8 2293 0.51 19.7 2362 0.56 21 2431 0.60 21 2501 0.65 0 65 22 1429 0.18 9.8 1506 0.20 10.8 1580 0.23 11.8 1655 0.25 13.0 1728 0.28 13.8 1801 0.31 14.5 1874 0.34 15.3 1945 0.37 16.1 2017 0.41 16.9 2089 0.45 17.7 2159 0.49 18.5 2231 0.53 19.4 2301 0.57 20 2372 0.62 21 2442 0.67 0 67 22 1335 0.19 9.4 1413 0.22 10.4 1489 0.24 11.4 1567 0.27 12.6 1643 0.29 13.4 1720 0.32 14.2 1797 0.35 15.0 1872 0.39 15.7 1947 0.42 16.5 2022 0.46 17.4 2095 0.50 18.2 2169 0.54 19.1 2240 0.59 19.9 2313 0.64 21 2386 0.69 0 69 22 1239 0.20 9.0 1324 0.23 10.0 1405 0.25 11.0 1485 0.28 12.2 1563 0.31 13.0 1641 0.34 13.8 1719 0.37 14.6 1795 0.40 15.4 1872 0.44 16.2 1950 0.48 17.0 2025 0.52 17.9 2102 0.56 18.8 2176 0.61 19.7 2252 0.65 21 2327 0.71 0 71 21 953 0.20 8.4 1083 0.23 9.4 1191 0.26 10.4 1293 0.29 11.5 1389 0.32 12.3 1482 0.36 13.1 1570 0.39 13.9 1652 0.43 14.7 1734 0.47 15.6 1814 0.51 16.4 1892 0.55 17.3 1970 0.59 18.2 2047 0.64 19.1 2124 0.69 20 2202 0.74 0 74 21 RPM Range Motor HP 1/4 1/3 1/2 RPM 3/4 1119 1166 1212 1259 1140 0.32 11.7 1264 0.36 12.5 1374 0.40 13.3 1475 0.44 14.2 1573 0.48 15.0 1668 0.53 15.8 1756 0.57 16.7 1843 0.62 17.6 1924 0.67 18.5 2006 0.72 19.5 2086 0.77 0 77 20 1305 1352 1399 1232 0.43 13.7 1364 0.48 14.6 1479 0.53 15.4 1583 0.58 16.3 1684 0.63 17.2 1779 0.68 18.1 1873 0.74 19.0 1963 0.80 0 80 19.9 19 9 1445 1492 1539 1356 0.57 15.8 1488 0.63 16.7 1602 0.68 17.6 1709 0.74 18.6 1811 0.81 0 81 19.5 19 5 1585 1632 1678 1725 1772 Performance shown is for Type A: free inlet, free outlet. Performance ratings do not include the effects of appurtenances (accessories). Power rating (BHP) does not include transmission losses. Bearing losses are included. The sound ratings shown are loudness values in hemispherical sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for installation Type A: free inlet hemispherical sone levels. 10 ALL SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE UBCA15 Performance Data CFM at Static Pressure 0.00 .125 .250 .375 .500 .750 1.00 1.25 1.50 2.00 BHP Sone BHP Sone BHP Sone BHP Sone BHP Sone BHP Sone BHP Sone BHP Sone BHP Sone BHP Sone 2188 0.27 10.1 2280 0.31 10.8 2370 0.35 11.6 2462 0.39 12.5 2552 0.44 13.4 2644 0.48 14.3 2736 0.54 15.4 2826 0.59 16.3 2917 0.65 17.4 3009 0.72 18.4 3099 0.78 19.5 3191 0.85 21 3281 0.93 22 2101 0.29 9.4 2197 0.33 10.2 2291 0.37 10.9 2386 0.41 11.8 2479 0.46 12.7 2574 0.50 13.6 2668 0.56 14.5 2761 0.61 15.6 2854 0.67 16.6 2948 0.74 17.6 3040 0.80 18.7 3134 0.88 19.8 3225 0.95 21 1967 0.31 9.5 2077 0.35 10.3 2183 0.39 11.0 2288 0.43 11.8 2388 0.48 12.6 2489 0.53 13.5 2589 0.58 14.3 2686 0.63 15.3 2784 0.70 16.3 2881 0.76 17.3 2976 0.83 18.3 3072 0.90 19.3 3166 0.98 20 1835 0.32 9.2 1939 0.36 10.1 2041 0.40 10.9 2148 0.45 11.8 2255 0.50 12.7 2365 0.55 13.6 2476 0.60 14.5 2583 0.66 15.4 2690 0.72 16.4 2795 0.78 17.3 2896 0.85 18.3 2998 0.93 19.3 3096 1.00 20 1722 0.33 8.5 1835 0.37 9.3 1940 0.42 10.3 2045 0.46 11.3 2147 0.51 12.3 2251 0.56 13.4 2356 0.62 14.4 2460 0.68 15.5 2569 0.74 16.5 2679 0.81 17.5 2788 0.88 18.4 2898 0.95 19.4 3004 1.03 21 1395 0.33 8.2 1533 0.38 9.1 1667 0.42 9.8 1804 0.48 10.5 1937 0.53 11.2 2062 0.59 12.1 2179 0.65 13.2 2286 0.71 14.3 2393 0.78 15.6 2498 0.85 16.9 2600 0.92 18.1 2704 1.00 19.3 2806 1.08 21 RPM Range Motor HP 1/3 1/2 3/4 RPM 1 1119 1166 1361 0.42 9.4 1512 0.47 10.0 1649 0.53 11.1 1787 0.59 12.3 1923 0.65 13.3 2058 0.72 14.0 2194 0.79 14.7 2323 0.87 15.7 2442 0.94 16.8 2555 1.03 18.1 2662 1.11 19.4 1212 1259 1305 1511 0.59 11.8 1664 0.65 12.4 1802 0.72 13.7 1940 0.79 15.0 2077 0.87 16.2 2211 0.95 17.0 2349 1.04 17.7 2481 1.13 18.5 1352 1399 1514 0.70 14.0 1693 0.79 14.2 1842 0.87 15.2 1981 0.95 16.6 2119 1.03 17.9 2252 1790 1.12 19.1 1.11 18.7 1445 1492 1539 1585 1632 1678 Performance shown is for Type A: free inlet, free outlet. Performance ratings do not include the effects of appurtenances (accessories). Power rating (BHP) does not include transmission losses. Bearing losses are included. The sound ratings shown are loudness values in hemispherical sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for installation Type A: free inlet hemispherical sone levels levels. ALL SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE 11 UBCA16 Performance Data CFM at Static Pressure 0.00 .125 .250 .375 .500 .750 1.00 1.25 1.50 BHP Sone BHP Sone BHP Sone BHP Sone BHP Sone BHP Sone BHP Sone BHP Sone BHP Sone BHP Sone 2628 0.28 10.3 2731 0.32 11.0 2837 0.36 11.7 2943 0.40 12.5 3046 0.44 13.3 3152 0.49 14.2 3258 0.54 15.1 3361 0.59 16.1 3467 0.65 17.1 3573 0.71 18.0 3679 0.78 19.0 3782 0.84 20 3888 0.92 21 4051 1.04 23 4157 1 12 24 1.12 4263 1.21 25 4372 1.30 26 4478 1.40 27 2432 0.30 9.7 2541 0.34 10.3 2653 0.38 11.1 2765 0.42 11.9 2873 0.47 12.6 2984 0.52 13.4 3095 0.57 14.3 3202 0.62 15.2 3313 0.68 16.2 3423 0.74 17.2 3533 0.81 18.2 3640 0.88 19.2 3749 0.95 20 3918 1.07 22 4027 1.16 1 16 23 4136 1.25 24 4247 1.34 25 4356 1.44 26 2281 0.32 9.3 2391 0.35 10.0 2503 0.39 10.8 2616 0.44 11.5 2726 0.48 12.4 2839 0.53 13.2 2952 0.59 14.1 3061 0.64 14.9 3174 0.70 15.9 3287 0.77 16.9 3399 0.83 17.8 3508 0.90 18.8 3620 0.98 19.9 3793 1.10 22 3904 1.19 1 19 23 4016 1.28 24 4130 1.38 25 4241 1.48 26 2156 0.33 9.3 2270 0.36 10.0 2386 0.41 10.8 2500 0.45 11.6 2610 0.50 12.5 2723 0.55 13.3 2836 0.60 14.2 2945 0.66 15.0 3058 0.72 16.0 3170 0.79 16.9 3283 0.85 17.8 3393 0.93 18.7 3506 1.00 19.7 3680 1.13 21 3793 1.21 1 21 22 3905 1.31 24 4021 1.41 25 4133 1.51 25 2009 0.34 8.9 2138 0.37 9.7 2264 0.42 10.6 2387 0.46 11.5 2503 0.51 12.4 2620 0.56 13.3 2735 0.62 14.2 2846 0.67 15.1 2960 0.73 16.1 3073 0.80 17.0 3186 0.87 17.9 3295 0.94 18.9 3408 1.02 19.9 3581 1.15 21 3694 1.24 1 24 23 3807 1.33 24 3923 1.43 24 4036 1.53 25 1407 0.30 7.7 1678 0.36 8.6 1895 0.42 9.5 2075 0.48 10.4 2229 0.53 11.5 2374 0.58 12.6 2511 0.64 13.6 2638 0.70 14.7 2764 0.76 15.8 2887 0.83 16.9 3007 0.90 17.9 3122 0.97 18.9 3238 1.05 20 3416 1.18 22 3530 1.27 1 27 23 3643 1.36 24 3759 1.47 25 3872 1.57 26 RPM Range Motor HP 2.00 1/3 1/2 3/4 1 RPM 1 1/2 918 954 991 1341 0.39 9.4 1657 0.48 10.3 1933 0.56 11.4 2154 0.64 12.4 2335 0.71 13.5 2500 0.78 14.7 2651 0.85 16.0 2793 0.92 17.2 2924 1.00 18.3 3054 1.08 19.5 3247 1.21 21 3369 1.30 1 30 23 3489 1.40 24 3610 1.50 25 3727 1.60 26 1028 1064 1101 1391 0.51 11.5 1721 0.62 12.4 2021 0.73 13.5 2270 0.83 14.6 2476 0.92 15.9 2650 1.01 17.2 2813 1.10 18.5 3041 1.24 21 3179 1.33 1 33 22 3312 1.43 23 3445 1.53 24 3570 1.64 25 1138 1174 1211 1537 0.67 13.8 1877 0.81 14.8 2172 0.94 15.9 2430 1.06 17.2 2749 1.23 19.3 2926 1.34 1 34 21 3087 1.45 22 3241 1.56 23 3384 1.67 25 1248 1285 1321 1358 1508 0.90 17.3 1880 1.09 1 09 18.4 18 4 2212 1.27 19.7 2521 1.45 21 2780 1.61 22 Performance shown is for Type A: free inlet, free outlet. Performance ratings do not include the effects of appurtenances (accessories). Power rating (BHP) does not include transmission losses. Bearing losses are included. The sound ratings shown are loudness values in hemispherical sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for installation Type A: free inlet hemispherical sone levels. 12 ALL SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE 1415 1452 1489 1527 1564 UBCA18 Performance Data CFM at Static Pressure 0.00 .125 .250 .375 .500 .750 1.00 1.25 1.50 BHP Sone BHP Sone BHP Sone BHP Sone BHP Sone BHP Sone BHP Sone BHP Sone BHP Sone BHP Sone 3344 0.43 10.6 3476 0.48 11.3 3610 0.54 12.1 3745 0.60 13.1 3876 0.67 14.0 4011 0.74 15.0 4146 0.82 16.0 4277 0.90 17.0 4412 0.99 18.0 4612 1.13 19.7 4747 1.23 21 4882 1.33 22 5020 1.45 23 5155 1.57 24 5290 1 70 25 1.70 5425 1.83 26 5563 1.98 27 3153 0.45 10.1 3296 0.50 10.8 3441 0.56 11.6 3585 0.63 12.4 3723 0.70 13.4 3865 0.77 14.3 4006 0.85 15.3 4143 0.93 16.4 4283 1.02 17.4 4490 1.16 19.0 4629 1.26 20 4768 1.37 21 4910 1.49 23 5048 1.61 23 5186 1.74 1 74 24 5324 1.87 25 5465 2.02 26 2924 0.46 9.5 3067 0.51 10.2 3214 0.57 11.0 3363 0.64 12.0 3509 0.71 12.9 3660 0.78 13.8 3812 0.86 14.8 3959 0.95 15.9 4109 1.04 16.9 4331 1.18 18.5 4479 1.29 19.7 4625 1.40 21 4774 1.52 22 4919 1.64 23 5062 1.77 1 77 24 5205 1.91 25 5351 2.05 26 2757 0.47 9.4 2906 0.52 10.2 3055 0.58 11.0 3202 0.65 11.8 3344 0.72 12.7 3490 0.79 13.6 3636 0.87 14.5 3778 0.96 15.6 3925 1.05 16.6 4147 1.19 18.1 4297 1.30 19.2 4448 1.41 20 4604 1.54 22 4755 1.66 22 4906 1.79 1 79 23 5056 1.93 24 5210 2.08 25 2568 0.48 9.2 2725 0.54 10.1 2887 0.60 10.9 3047 0.66 11.9 3200 0.73 12.8 3353 0.80 13.6 3503 0.88 14.6 3646 0.97 15.5 3792 1.06 16.5 4009 1.20 17.9 4155 1.31 19.0 4301 1.42 20 4452 1.55 21 4600 1.67 22 4749 1.80 1 80 23 4899 1.94 24 5054 2.09 25 2061 0.46 8.4 2319 0.53 9.3 2533 0.60 10.3 2715 0.67 11.3 2879 0.75 12.3 3043 0.83 13.3 3204 0.92 14.4 3362 1.00 15.5 3524 1.09 16.6 3762 1.24 18.1 3919 1.34 19.2 4072 1.45 20 4226 1.57 21 4375 1.70 22 4522 1.83 1 83 23 4668 1.97 24 4817 2.12 24 RPM Range Motor HP 2.00 1/2 3/4 1 1 1/2 RPM 2 918 954 1802 0.53 9.1 2127 0.62 10.2 2410 0.72 11.4 2674 0.81 12.6 2892 0.91 13.7 3074 1.00 14.9 3246 1.10 16.0 3490 1.26 17.7 3652 1.38 18.9 3814 1.49 20 3980 1.62 21 4142 1.74 22 4302 1.87 1 87 23 4460 2.01 24 4618 2.15 25 991 1028 1064 1948 0.72 11.2 2284 0.84 12.5 2575 0.95 13.8 2853 1.07 15.2 3198 1.25 17.1 3390 1.37 18.3 3565 1.49 19.6 3737 1.63 21 3900 1.76 22 4062 1.90 1 90 23 4223 2.05 24 4390 2.20 25 1101 1138 1781 0.80 12.5 2181 0.96 13.6 2662 1.17 15.9 2951 1.31 17.3 3219 1.46 18.8 3454 1.60 20 3652 1.75 21 3832 1.90 1 90 22 4002 2.05 23 4171 2.22 24 1174 1211 1266 1303 1845 1.13 16.4 2314 1.37 17.4 2674 1.57 18.7 2993 1.76 1 76 20 3288 1.94 21 3574 2.14 23 1340 1378 1415 1452 1489 1527 Performance shown is for Type A: free inlet, free outlet. Performance ratings do not include the effects of appurtenances (accessories). Power rating (BHP) does not include transmission losses. Bearing losses are included. The sound ratings shown are loudness values in hemispherical sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for installation Type A: free inlet hemispherical sone levels. ALL SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE 13 UBCA20 Performance Data CFM at Static Pressure 0.00 .125 .250 .375 .500 .750 1.00 1.25 1.50 BHP Sone BHP Sone BHP Sone BHP Sone BHP Sone BHP Sone BHP Sone BHP Sone BHP Sone BHP Sone 3857 0.41 10.8 4037 0.47 11.6 4222 0.53 12.5 4407 0.61 13.5 4593 0.69 14.5 4773 0.77 15.6 4958 0.86 16.7 5143 0.96 17.8 5403 1.12 19.4 5588 1.24 20 5773 1.36 22 5958 1.50 23 6148 1.65 24 6333 1.80 25 6519 1 96 26 1.96 3620 0.43 9.8 3812 0.49 10.7 4008 0.56 11.5 4203 0.64 12.5 4397 0.72 13.4 4585 0.80 14.4 4778 0.90 15.6 4970 1.00 16.7 5239 1.16 18.3 5430 1.28 19.5 5620 1.41 21 5810 1.54 22 6005 1.69 23 6194 1.85 24 6384 2.01 2 01 25 3383 0.45 9.4 3580 0.51 10.2 3783 0.58 11.1 3986 0.66 12.0 4189 0.74 12.9 4385 0.83 14.0 4586 0.92 15.1 4785 1.03 16.2 5064 1.19 17.8 5262 1.31 18.9 5459 1.44 20 5655 1.58 21 5855 1.73 23 6049 1.89 24 6243 2.05 2 05 24 3189 0.46 9.1 3390 0.52 10.0 3594 0.59 11.0 3797 0.67 12.1 3999 0.76 13.1 4196 0.84 14.1 4399 0.94 15.1 4603 1.05 16.2 4888 1.21 17.7 5090 1.33 18.7 5292 1.47 19.8 5493 1.61 21 5699 1.76 22 5898 1.92 23 6097 2.09 2 09 24 2931 0.47 8.6 3185 0.54 9.6 3415 0.61 10.7 3630 0.69 11.9 3838 0.77 13.1 4037 0.86 14.2 4240 0.96 15.3 4443 1.07 16.4 4727 1.23 17.8 4930 1.35 18.9 5133 1.49 20 5336 1.63 21 5545 1.78 22 5748 1.94 23 5950 2.11 2 11 24 2092 0.43 7.3 2485 0.52 8.6 2801 0.61 10.1 3091 0.70 11.4 3383 0.80 12.3 3662 0.89 13.4 3918 0.99 14.7 4149 1.10 15.9 4451 1.27 17.8 4660 1.39 19.0 4865 1.53 20 5069 1.67 22 5277 1.83 23 5479 1.99 24 5682 2.16 2 16 25 RPM Range Motor HP 2.00 1/2 3/4 1 1 1/2 RPM 2 771 807 844 2295 0.63 9.8 2733 0.76 11.1 3066 0.88 12.8 3365 0.99 14.3 3653 1.11 15.5 4065 1.30 17.0 4339 1.43 18.2 4586 1.57 19.6 4814 1.71 21 5036 1.87 23 5247 2.04 24 5454 2.21 2 21 25 881 918 954 2645 0.91 12.6 3073 1.07 14.2 3539 1.28 16.6 3833 1.42 17.9 4121 1.58 19.2 4415 1.74 20 4708 1.91 22 4969 2.08 23 5209 2.25 2 25 24 991 1028 2824 1.16 15.1 3270 1.35 16.6 3631 1.54 18.4 3941 1.72 20 4240 1.90 21 4529 2.08 22 4823 2.27 2 27 23 1080 1117 1154 2338 1.36 18.8 3006 1.66 19.4 3503 1.92 21 3914 2.18 2 18 22 Performance shown is for Type A: free inlet, free outlet. Performance ratings do not include the effects of appurtenances (accessories). Power rating (BHP) does not include transmission losses. Bearing losses are included. The sound ratings shown are loudness values in hemispherical sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for installation Type A: free inlet hemispherical sone levels. 14 ALL SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE 1191 1229 1266 1303 UBCA24 Performance Data CFM at Static Pressure 0.00 .125 .250 .375 .500 .750 1.00 1.25 1.50 BHP Sone BHP Sone BHP Sone BHP Sone BHP Sone BHP Sone BHP Sone BHP Sone BHP Sone BHP Sone 4154 0.30 7.7 4440 0.36 8.8 4749 0.44 10.0 5028 0.53 11.1 5277 0.61 12.3 5526 0.70 13.5 5805 0.81 14.8 6068 0.92 16.1 6340 1.05 17.4 6634 1.21 18.9 6898 1.36 20 7192 1.54 22 7501 1.75 23 7825 1.98 25 8254 2.33 28 8669 2.69 30 9099 3.12 33 3809 0.31 7.2 4122 0.38 8.3 4456 0.47 9.6 4755 0.56 10.8 5019 0.64 12.0 5282 0.74 13.2 5575 0.85 14.6 5850 0.97 15.9 6132 1.10 17.3 6437 1.26 18.7 6709 1.41 20 7012 1.60 22 7329 1.81 24 7661 2.05 25 8100 2.40 28 8522 2.77 31 8959 3.20 34 3351 0.32 6.7 3725 0.39 7.8 4121 0.48 9.0 4449 0.57 10.2 4729 0.65 11.5 5005 0.74 12.7 5311 0.86 14.2 5600 0.98 15.5 5895 1.12 16.9 6213 1.28 18.4 6496 1.44 19.9 6810 1.63 22 7138 1.84 24 7481 2.09 25 7931 2.45 28 8364 2.83 31 8810 3.26 34 2712 0.31 6.4 3243 0.39 7.4 3675 0.48 8.5 4030 0.57 9.7 4350 0.65 10.8 4678 0.75 12.1 5032 0.87 13.6 5345 1.00 15.0 5654 1.13 16.4 5982 1.29 18.0 6273 1.45 19.4 6595 1.63 21 6933 1.85 23 7285 2.10 25 7749 2.46 28 8193 2.85 31 8650 3.29 35 RPM Range Motor HP 2.00 1/3 1/2 3/4 1 1 1/2 RPM 2 3 551 589 3023 0.47 8.3 3584 0.57 9.3 3966 0.66 10.4 4297 0.76 11.6 4651 0.87 13.0 4990 1.00 14.4 5348 1.14 15.8 5725 1.31 17.4 6044 1.47 18.8 6383 1.65 21 6730 1.87 23 7089 2.11 25 7561 2.47 28 8014 2.86 31 8480 3.30 34 630 667 700 733 3674 0.85 12.4 4230 0.99 13.7 4679 1.14 15.0 5089 1.31 16.5 5429 1.47 17.7 5801 1.66 19.2 6201 1.88 21 6629 2.14 23 7172 2.51 26 7660 2.90 29 8145 3.34 33 770 805 841 4073 1.25 16.0 4672 1.45 17.2 5202 1.67 18.4 5662 1.90 19.9 6091 2.15 22 6636 2.51 24 7171 2.90 27 7738 3.37 30 880 915 3951 1.54 18.1 4760 1.83 19.5 5443 2.13 21 6144 5303 2.53 23 2.45 23 6707 6138 2.92 26 2.91 25 7255 6811 5004 3.36 28 3.38 28 3.12 27 954 995 1038 1095 1150 1207 Performance shown is for Type A: free inlet, free outlet. Performance ratings do not include the effects of appurtenances (accessories). Power rating (BHP) does not include transmission losses. Bearing losses are included. The sound ratings shown are loudness values in hemispherical sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for installation Type A: free inlet hemispherical sone levels. ALL SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE 15 UBCA30 Performance Data CFM at Static Pressure 0.00 .125 .250 .375 .500 .750 1.00 1.25 1.50 BHP Sone BHP Sone BHP Sone BHP Sone BHP Sone BHP Sone BHP Sone BHP Sone BHP Sone BHP Sone 5019 0.23 4.6 5530 0.31 5.6 6097 0.41 7.1 6526 0.51 8.3 7217 0.69 10.5 7687 0.83 12.2 8212 1.01 14.0 8572 1.15 14.9 8959 1.31 15.9 9305 1.47 16.8 9747 1.69 18.0 10231 1.95 19.4 10646 2.20 21 11102 2.50 22 11475 2.76 23 11849 3.04 24 12443 3.52 26 12996 4.01 29 13618 4.61 32 14199 5.23 35 4322 0.24 4.2 4899 0.32 5.2 5525 0.43 6.6 5992 0.52 7.7 6735 0.71 9.9 7234 0.85 11.6 7789 1.03 13.5 8166 1.17 14.3 8571 1.34 15.4 8931 1.50 16.2 9391 1.72 17.4 9891 1.98 18.8 10319 2.23 20 10789 2.53 21 11173 2.79 23 11555 3.07 24 12164 3.55 26 12729 4.04 28 13363 4.65 31 13954 5.26 34 3239 0.24 3.5 4177 0.33 4.5 4928 0.44 6.0 5447 0.54 7.2 6248 0.72 9.3 6779 0.87 11.0 7363 1.05 12.9 7758 1.19 13.9 8181 1.36 14.9 8556 1.52 15.8 9033 1.74 16.9 9550 2.01 18.4 9992 2.26 19.5 10475 2.56 21 10869 2.82 22 11262 3.10 23 11884 3.58 26 12461 4.08 28 13108 4.68 31 13710 5.30 34 RPM Range Motor HP 2.00 1/2 3/4 1 1 1/2 2 RPM 3 363 400 3818 0.43 5.4 4736 0.55 6.7 5719 0.74 8.8 6305 0.88 10.5 6930 1.07 12.5 7347 1.21 13.5 7789 1.38 14.5 8179 1.54 15.4 8673 1.77 16.6 9208 2.03 18.0 9663 2.29 19.2 10160 2.58 20 10565 2.85 22 10967 3.13 23 11604 3.62 25 12193 4.11 27 12852 4.72 30 13464 5.34 33 441 472 4876 0.73 8.3 5709 0.89 10.1 6446 1.09 12.1 6906 1.23 13.1 7380 1.40 14.2 7793 1.56 15.1 8309 1.79 16.3 8864 2.06 17.7 9334 2.31 18.9 9844 2.61 20 10259 2.88 21 10671 3.16 23 11323 3.65 25 11924 4.14 27 12595 4.75 30 13218 5.38 33 522 556 594 620 6220 1.40 13.4 6821 1.58 14.5 7474 1.82 15.8 8119 2.10 17.3 8641 2.35 18.6 9195 2.66 19.9 9638 2.93 21 10074 3.21 22 10757 3.70 24 11384 4.20 26 12081 4.82 29 12725 5.45 32 648 673 705 6951 2.08 16.5 7717 2.37 18.0 8415 2.69 19.5 8932 2.97 21 9420 3.26 22 10162 3.76 24 10828 4.26 26 11559 4.88 29 12228 5.51 31 740 770 803 7847 2.94 20 8538 3.26 22 9452 3.79 24 10207 4.30 26 10999 4.93 28 11710 5.57 31 830 857 8317 3.73 23 9381 4.31 25 10336 7170 4.96 28 4.47 25 11131 9172 5.61 30 5.49 29 Performance shown is for Type A: free inlet, free outlet. Performance ratings do not include the effects of appurtenances (accessories). Power rating (BHP) does not include transmission losses. Bearing losses are included. The sound ratings shown are loudness values in hemispherical sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for installation Type A: free inlet hemispherical sone levels. 16 5 ALL SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE 900 940 985 1027 UBCA36 Performance Data CFM at Static Pressure 0.00 .125 .250 .375 .500 .750 1.00 1.25 1.50 BHP Sone BHP Sone BHP Sone BHP Sone BHP Sone BHP Sone BHP Sone BHP Sone BHP Sone BHP Sone 6843 0.28 4.3 7562 0.38 5.4 8207 0.48 6.5 8926 0.62 7.8 9694 0.80 9.4 10686 1.07 11.8 11405 1.30 13.6 12223 1.60 15.2 12892 1.87 16.6 13562 2.18 18.0 14256 2.53 19.6 15000 2.95 21 15545 3.28 23 16240 3.74 24 16983 4.28 26 17727 4.87 28 18372 5.42 30 19215 6.20 33 20082 7.07 36 20826 7.89 39 5746 0.29 3.7 6634 0.40 4.8 7385 0.50 5.9 8193 0.65 7.2 9035 0.82 8.7 10101 1.10 11.0 10863 1.33 12.8 11722 1.63 14.4 12421 1.91 15.8 13116 2.22 17.2 13834 2.58 18.8 14600 3.00 21 15161 3.33 22 15873 3.79 24 16634 4.33 25 17393 4.92 27 18049 5.48 29 18907 6.26 32 19789 7.14 35 20544 7.96 38 RPM Range Motor HP 2.00 3/4 1 1 1/2 2 3 RPM 5 7 1/2 276 4858 0.38 4.4 6031 0.50 5.5 7113 0.65 6.9 8148 0.84 8.4 9373 1.12 10.7 10214 1.36 12.4 11142 1.66 14.0 11885 1.95 15.3 12617 2.26 16.7 13368 2.62 18.2 14165 3.04 20 14745 3.38 21 15479 3.84 23 16261 4.38 25 17039 4.98 27 17710 5.53 29 18586 6.32 31 19483 7.20 34 20250 8.02 37 305 331 360 6788 0.82 8.0 8358 1.12 10.4 9365 1.36 12.2 10424 1.68 13.8 11245 1.97 15.1 12038 2.28 16.4 12839 2.65 17.9 13679 3.07 19.5 14286 3.41 21 15049 3.88 23 15858 4.43 24 16660 5.02 26 17349 5.58 28 18245 6.37 31 19161 7.26 34 19943 8.08 36 391 431 8200 1.34 11.9 9481 1.67 13.6 10437 1.97 14.9 11332 2.30 16.2 12214 2.66 17.8 13121 3.10 19.4 13767 3.44 21 14572 3.92 22 15417 4.47 24 16248 5.07 26 16961 5.63 28 17882 6.42 30 18821 7.31 33 19619 8.14 36 460 493 520 9335 2.23 15.7 10513 2.63 17.3 11655 3.09 19.0 12442 3.45 20 13391 3.94 22 14359 4.51 24 15288 5.12 26 16070 5.69 27 17066 6.50 30 18067 7.40 33 18911 8.24 35 547 575 9430 2.95 18.3 10567 3.35 19.7 11779 3.87 22 12953 4.47 23 14051 5.11 25 14951 5.70 27 16072 6.53 29 17175 7.45 32 18089 8.30 35 605 627 655 11023 4.32 23 12442 5.00 25 13519 5.63 27 14824 6.49 29 16082 7.44 32 17103 8.31 35 685 715 11551 5.42 26 13266 6.35 28 14741 9310 7.35 31 6.37 29 15904 12267 8.25 34 7.76 33 741 775 810 840 Performance shown is for Type A: free inlet, free outlet. Performance ratings do not include the effects of appurtenances (accessories). Power rating (BHP) does not include transmission losses. Bearing losses are included. The sound ratings shown are loudness values in hemispherical sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for installation Type A: free inlet hemispherical sone levels. ALL SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE 17 UBCA44 Performance Data CFM at Static Pressure 0.00 .125 .250 .375 .500 .750 1.00 1.25 BHP Sone BHP Sone BHP Sone BHP Sone BHP Sone BHP Sone BHP Sone BHP Sone BHP Sone 11013 0.57 4.6 11627 0.68 5.2 12504 0.84 6.1 13250 1.00 6.9 14479 1.31 8.2 15269 1.53 9.2 16014 1.77 10.1 16629 1.98 11.0 17462 2.29 12.2 18428 2.69 13.6 19481 3.18 15.1 20709 3.82 16.8 21718 4.41 18.3 22596 4.97 19.6 23561 5.63 21 24570 6.38 23 25448 7.09 24 26457 7.97 26 27422 8.87 28 28387 9.85 30 29002 10.50 31 9673 0.61 4.3 10372 0.72 4.9 11352 0.89 5.8 12172 1.05 6.6 13503 1.36 8.0 14348 1.59 9.0 15140 1.83 10.0 15790 2.04 10.8 16666 2.36 12.0 17676 2.77 13.5 18772 3.26 14.9 20045 3.90 16.7 21086 4.50 18.1 21989 5.06 19.5 22980 5.72 21 24014 6.48 23 24911 7.19 24 25942 8.08 26 26925 8.98 28 27908 9.96 29 28532 10.61 31 7505 0.61 3.8 8657 0.73 4.3 9934 0.91 5.2 10904 1.08 6.0 12402 1.40 7.5 13327 1.64 8.5 14183 1.88 9.5 14878 2.10 10.3 15809 2.42 11.6 16873 2.83 13.1 18021 3.33 14.6 19346 3.98 16.4 20424 4.57 17.9 21357 5.14 19.2 22377 5.81 21 23438 6.57 22 24357 7.29 24 25411 8.18 26 26415 9.09 27 27416 10.07 29 28052 10.73 31 RPM Range Motor HP 1.50 1 1 1/2 2 3 5 RPM 7 1/2 251 265 285 8558 1.04 5.7 10976 1.41 7.0 12104 1.66 7.9 13084 1.91 8.9 13854 2.14 9.8 14867 2.47 11.0 16006 2.88 12.5 17219 3.39 14.1 18606 4.05 16.0 19729 4.65 17.5 20695 5.22 18.9 21748 5.89 20 22840 6.66 22 23784 7.38 24 24863 8.27 25 25889 9.19 27 26911 10.17 29 27559 10.83 30 302 330 9785 1.59 7.6 11515 1.89 8.5 12536 2.14 9.3 13746 2.48 10.4 15025 2.92 11.9 16341 3.43 13.6 17815 4.10 15.5 18992 4.71 17.0 19999 5.28 18.4 21090 5.97 20 22218 6.74 22 23189 7.47 23 24296 8.36 25 25347 9.28 27 26391 10.27 29 27053 10.94 30 348 365 379 398 11105 2.75 11.5 13855 3.40 13.1 15870 4.13 14.9 17286 4.78 16.5 18436 5.38 17.9 19648 6.08 19.5 20875 6.87 21 21918 7.61 23 23096 8.52 25 24205 9.45 26 25301 10.45 28 25993 11.12 30 420 444 11061 3.73 13.9 14211 4.61 15.4 16189 5.31 16.7 17797 6.08 18.2 19266 6.92 19.8 20452 7.69 21 21753 8.62 23 22954 9.58 25 24124 10.60 27 24857 11.28 28 472 495 515 13614 5.67 17.7 16649 6.73 19.3 18434 7.60 21 20073 8.61 22 21473 9.62 24 22782 10.67 26 23583 11.37 27 537 560 13808 6.97 20 16981 8.29 22 19346 9.45 24 21058 10.60 25 22019 11.34 26 Performance shown is for Type A: free inlet, free outlet. Performance ratings do not include the effects of appurtenances (accessories). Power rating (BHP) does not include transmission losses. Bearing losses are included. The sound ratings shown are loudness values in hemispherical sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for installation Type A: free inlet hemispherical sone levels. 18 10 ALL SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE 580 603 625 647 661 UDCA Direct Drive Centrifugal Upblast Power Roof Ventilators Applications The UDCA units are quiet, dependable upblast power roof ventilators for the exhaust of grease-laden air from restaurant range hoods, and general ventilation applications where vertical discharge of exhaust air is required. Applications include virtually all types of commercial and institutional kitchens, such as restaurant and cafeteria, fast food, hospital, hotel and motel, bakery, delicatessen, school and military. UDCA units are specified where a roof-mounted location is desired to eliminate interference with other equipment or activities in the building. They permit the direct upward venting of overheated air. The UDCA is listed under UL classification YZHW for Power Roof Ventilators for Restaurant Exhaust Systems. When properly installed, the UDCA also meets the requirements of National Fire Protection Association Standard NFPA 96. These units are particularly recommended for economical and efficient range hood ventilation where continuous operation under severe conditions may cause other power roof ventilators to fail. Type UDCA ventilators are UL762 Listed by Underwriters Laboratory Inc. UL762 - MH9847 American Coolair Corporation, ILG Industries certifies that the Type UDCA PRVs shown herein are licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and AMCA Publication 311 and comply with the requirements of the AMCA Certified Ratings Program. Construction UDCA models feature a housing of durable spun aluminum for optimum weather protection. The overlapping deep spun venturi minimizes air turbulence and increases efficiency. The aluminum centrifugal wheel is a non-overloading, backward-inclined type, selected for low noise levels. Backplate fins draw cool air through the motor compartment. The wheels are computer balanced on state-of-the-art equipment. The hub features a line bore, which eliminates the need for bushings. The motor compartment cover is easily removable for complete access to the motor, and a factory wired safety disconnect device is standard. Drive Mechanism UDCA models have all the advantages of a direct drive assembly. There are no belts, pulleys, or bearings to consume power or require maintenance. Motors The standard motor for UDCA models is open construction, located out of the airstream. Totally enclosed, energy efficient, two-speed and explosion-proof motors may also be available. Motor enclosure may affect UL Listing. All motor brands are recognized and serviced nationwide. Guide Specifications Upblast power roof ventilators shall be of the UDCA centrifugal type as manufactured by ILG Industries of American Coolair Corporation (individual models to be listed in fan schedule). Units shall meet UL Standard 762 as required and shall bear the AMCA Certified Ratings Seal for air and sound performance. Bottom outer housing and venturi inlet shall be one piece heavy gauge spun aluminum with built-in grease drain. Wheel and venturi shall overlap for efficient operation. Motor compartment cover shall be heavy gauge spun aluminum construction and easily removable for access to motor and drive. Motor compartment disc and support pipes shall be heavy gauge steel. Drive mechanism shall be of direct-drive design. The line bore hub shall be mounted onto the backplate of the centrifugal wheel. The centrifugal wheel shall be heavy gauge aluminum with backward-inclined, non-overloading blades and be computer balanced. Motor shall be open construction, NEMA design B. Optional variable speed control allows for field adjustment and system balance. The unit shall be equipped with a wired and mounted safety disconnect device. (Epoxy coating, roof curb and other accessories shall be listed in the fan schedule.) 19 ILG UDCA12-UDCA13 Performance Data UDCA12 0.00 CFM at Static Pressure .125 .250 .375 .500 .625 .750 RPM RANGE 1.00 1.25 1.50 BHP Sone BHP Sone BHP Sone BHP Sone BHP Sone BHP Sone BHP Sone BHP Sone BHP Sone BHP Sone 970 0.05 4.2 1056 0.06 5.0 1142 0.08 5.8 1227 0.10 6.8 1313 0.12 7.8 1399 0.14 8.9 1484 0.17 10.1 1570 0.20 11.5 1656 0.24 12.8 1741 0.27 14.2 1827 0.32 15.2 1930 0.37 16.7 844 0.05 3.8 939 0.07 4.6 1033 0.09 5.6 1125 0.11 6.6 1217 0.13 7.7 1308 0.15 8.8 1398 0.18 10.0 1488 0.22 11.4 1578 0.25 12.7 1667 0.29 14.1 1756 0.33 15.2 1862 0.39 16.5 709 0.06 3.4 821 0.08 4.3 926 0.09 5.3 1027 0.11 6.3 1126 0.14 7.3 1222 0.16 8.4 1318 0.19 9.6 1412 0.23 11.0 1505 0.26 12.4 1597 0.30 13.7 1689 0.35 14.9 1798 0.41 16.3 670 0.08 4.0 803 0.10 4.9 920 0.12 5.9 1030 0.14 6.9 1134 0.17 8.1 1236 0.20 9.3 1335 0.24 10.5 1433 0.27 11.9 1529 0.32 13.3 1624 0.36 14.4 1736 0.42 16.0 .250 .375 UDCA13 0.00 925 619 0.09 4.6 787 0.12 5.6 920 0.15 6.6 1038 0.18 7.6 1149 0.21 8.8 1255 0.24 10.1 1358 0.28 11.6 1459 0.32 12.9 1558 0.37 14.1 1674 0.43 15.7 1000 1075 771 0.14 6.4 923 0.18 7.4 1052 0.21 8.4 1169 0.25 9.7 1279 0.29 11.1 1386 0.33 12.4 1490 0.38 13.7 1611 0.44 15.4 1150 758 0.17 7.1 931 0.21 8.3 1070 0.25 9.4 1193 0.30 10.7 1308 0.34 12.0 1418 0.39 13.3 1545 0.45 15.1 1225 1300 1375 965 0.29 10.4 1121 0.34 11.5 1256 1028 0.40 12.7 0.39 12.4 1403 1225 0.47 14.4 0.47 14.0 1450 1525 1600 1690 .500 .625 .750 RPM RANGE 1.00 1.25 1.50 BHP Sone BHP Sone BHP Sone BHP Sone BHP Sone BHP Sone BHP Sone BHP Sone BHP Sone BHP Sone 1157 0.06 5.2 1265 0.08 6.2 1374 0.10 7.4 1482 0.12 8.6 1590 0.15 10.1 1699 0.18 11.7 1807 0.22 13.3 1952 0.28 15.1 2060 0.33 16.3 2169 0.38 17.6 2277 0.44 19.0 1026 0.07 4.5 1146 0.09 5.7 1264 0.11 6.9 1380 0.13 8.2 1495 0.16 9.7 1609 0.20 11.3 1723 0.24 13.1 1874 0.29 14.8 1986 0.34 16.0 2098 0.40 17.3 2210 0.46 18.6 894 0.07 4.1 1026 0.09 5.3 1153 0.12 6.5 1278 0.14 7.9 1401 0.17 9.4 1522 0.21 11.0 1641 0.25 12.7 1798 0.31 14.5 1914 0.36 15.7 2030 0.42 17.0 2144 0.48 18.3 UDCA13J15 RPM 1/2 HP 800 883 0.10 5.0 1038 0.12 6.2 1176 0.15 7.5 1305 0.18 9.0 1432 0.22 10.6 1556 0.26 12.3 1720 0.32 14.1 1841 0.37 15.4 1961 0.43 16.7 2079 0.49 18.0 875 879 0.12 5.9 1051 0.16 7.2 1204 0.19 8.6 1343 0.23 10.2 1473 0.27 11.9 1642 0.33 13.8 1767 0.39 15.0 1890 0.45 16.3 2012 0.51 17.7 950 881 0.15 6.9 1073 0.19 8.4 1236 0.23 9.9 1385 0.28 11.6 1565 0.35 13.4 1694 0.40 14.7 1820 0.46 16.0 1945 0.53 17.4 1025 1100 1104 0.23 9.6 1276 0.28 11.2 1481 0.35 13.0 1619 0.41 14.4 1751 0.47 15.7 1879 0.54 17.1 1175 1250 1259 0.36 12.5 1433 0.42 13.8 1592 1384 0.49 15.2 0.49 14.7 1740 1562 1324 0.56 16.5 0.57 16.1 0.55 15.6 Performance shown is for Type A: free inlet, free outlet. Performance ratings do not include the effects of appurtenances (accessories The sound ratings shown are loudness values in hemispherical sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard 301 Values shown are for installation Type A: free inlet hemispherical sone levels AMCA Certified Ratings apply only to the UDCA Roof Ventilator constant speed fans and not variable speed fans 20 RPM 1/2 HP 850 CFM at Static Pressure .125 UDCA12J16 ALL SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE 1350 1425 1500 1575 UDCA15 Performance Data CFM at Static Pressure 0.00 .125 .250 .375 .500 .625 .750 RPM RANGE 1.00 1.25 1.50 BHP Sone BHP Sone BHP Sone BHP Sone BHP Sone BHP Sone BHP Sone BHP Sone BHP Sone BHP Sone 1565 0.10 5.7 1712 0.13 6.8 1858 0.17 7.9 2005 0.21 8.9 2152 0.26 9.9 2299 0.32 11.0 2445 0.38 12.3 2592 0.46 13.8 2739 0.54 15.4 2885 0.63 17.0 3032 0.73 18.6 1411 0.11 5.3 1583 0.14 6.3 1747 0.18 7.3 1905 0.23 8.2 2061 0.28 9.2 2215 0.34 10.3 2368 0.40 11.6 2519 0.48 13.1 2671 0.56 14.6 2821 0.65 16.2 2971 0.75 17.9 1240 0.12 4.7 1413 0.16 6.1 1579 0.20 7.3 1747 0.24 8.2 1922 0.29 9.2 2097 0.35 10.4 2267 0.42 11.6 2431 0.50 12.9 2590 0.58 14.4 2748 0.67 15.9 2904 0.78 17.5 1014 0.12 4.5 1231 0.16 5.6 1443 0.20 6.5 1625 0.25 7.7 1793 0.31 8.9 1959 0.37 10.2 2128 0.44 11.6 2301 0.52 13.1 2478 0.60 14.5 2651 0.70 16.0 2819 0.80 17.6 UDCA15K15 RPM 3/4 HP 800 1023 0.16 5.4 1247 0.20 6.5 1464 0.26 7.3 1674 0.32 8.2 1856 0.38 9.5 2026 0.45 11.1 2192 0.53 12.8 2359 0.62 14.5 2529 0.72 16.1 2704 0.82 17.7 875 1049 0.20 6.4 1286 0.26 7.1 1503 0.32 8.3 1722 0.39 9.2 1923 0.46 10.4 2101 0.55 12.1 2270 0.64 13.9 2436 0.74 15.8 2603 0.85 17.6 950 1086 0.25 7.5 1341 0.32 7.9 1560 0.39 9.3 1778 0.47 10.4 1992 0.55 11.6 2182 0.65 13.3 2355 0.75 15.2 2523 0.86 17.2 1025 1100 1211 0.38 9.3 1487 0.46 10.4 1710 0.55 11.6 1927 0.65 13.3 2145 0.77 15.2 2353 0.89 17.2 1175 1250 1409 0.55 11.7 1670 0.65 13.3 1893 1636 0.76 14.5 0.76 14.6 2110 1879 0.89 15.9 0.89 16.4 1325 1400 1475 1550 Performance shown is for Type A: free inlet, free outlet. Performance ratings do not include the effects of appurtenances (accessories The sound ratings shown are loudness values in hemispherical sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard 301 Values shown are for installation Type A: free inlet hemispherical sone levels AMCA Certified Ratings apply only to the UDCA Roof Ventilator constant speed fans and not variable speed fans ALL SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE 21 Installation Maintenance Most models are shipped fully assembled and ready for installation. Always inspect equipment for transit damage before accepting delivery to assure a valid claim. Special handling and storage procedures are required if unit is to remain idle for a long time prior to installation. Units should be checked monthly for the first two or three months and periodically thereafter. Placement All belt-driven units must be accessibly installed for maintenance of belts, bearings, motors and pulleys and routine cleaning. Mounting Satisfactory operation of roof ventilators requires mounting on adequately designed and constructed roof curbs. Prefabricated curbs for convenience in installation are available from ILG. Install with base of unit horizontal. Provide adequate caulking, flashing or other weatherproofing means. Duct connections are made below the unit. Inspection Check centrifugal wheel for free rotation. Cleaning Units should be cleaned of grease and material buildup every three months or when necessary, depending on the condition of air being exhausted and frequency of use. Grease trough, drain and container should be checked and emptied as required to prevent grease overflow, as often as every one or two weeks with heavy grease applications such as char-broilers. Units should also be checked for eroded parts which should be replaced to avoid structural damage and possible failure. Lubrication Proper lubrication is the most important maintenance requirement. On UBCA units, fan bearings should be lubricated annually or more frequently based on usage and operating conditions. For best results, use a #2 consistency lithium based grease such as Shell Alvania #2 or equivalent lubricant. Motor bearings should be lubricated according to the motor manufacturer’s instructions. Check belt for proper tension (UBCA). Check bearings for proper and secure locking to drive shaft (UBCA). Adjustment of Variable Pitch Pulley and Belt (UBCA Only) Check motor and fan sheave faces for proper alignment (UBCA). Variable pitch pulley may be adjusted within catalog RPM range to alter performance. However, adjustment beyond catalog RPM range may cause motor overload and possible premature motor failure. Pulley alignment and belt tension should be adjusted if necessary. Both motor and driven pulleys should be at right angles to the shafts, and the V-grooves should be aligned with each other. Inspection of drive components every 6 to 12 months is recommended. Check circuit phase, voltage and wiring connection against that shown on motor nameplate. Check direction of fan rotation for proper air flow. Check belt after one week of operation for proper tension (UBCA). WARNING CAUTION DO NOT INSTALL FAN WITH MOVING PARTS WITHIN 8 FEET OF FLOOR OR GRADE LEVEL WITHOUT A GUARD THAT COMPLIES WITH OSHA REGULATIONS. DO NOT USE UNLESS ELECTRICAL WIRING COMPLIES WITH ALL APPLICABLE CODES. DO NOT WIRE WITHOUT PROVIDING FOR A POWER SOURCE DISCONNECT AT THE FAN ITSELF. DO NOT SERVICE EXCEPT BY A QUALIFIED MAINTENANCE TECHNICIAN AND ONLY AFTER DISCONNECTING THE POWER SOURCE. FAILURE TO OBSERVE THESE PRECAUTIONS CAN RESULT IN SERIOUS INJURY OR DEATH. To convert air performance (CFM and SP) and power (BHP) to metric units, multiply CFM x .000472 to obtain cubic meters per second (m3/s). Multiply SP x 248.36 to obtain pascals (Pa). Multiply BHP x .7457 to obtain kilowatts (kW). Example: 3904 CFM x .000472 = 1.8427 m3/s 0.125 SP x 24.36 = 31.05 Pa 0.886 BHP x .7457 = 0.661 kW ILG 22 UBCA/UDCA Options and Accessories Grease Extraction Application Accessories General Ventilation Accessories Prefabricated Roof Curbs Prefabricated Roof Curbs Roof curbs for grease extraction UBCA and UDCA models meet NFPA 96 system requirements for minimum PRV discharge height above the roof line. Curb height for sizes 18 and below is 20”, and for sizes 20 and above is 18”. Curbs with venting on two or four sides are also available. All curbs are insulated, feature a weather-resistant, continuous welded construction and provide convenience in installation of PRV units for both insulated and noninsulated roof decks. Insulated roof curbs with weather-resistant continuous welded construction are available for convenience in installation for both insulated and non-insulated roof decks. Safety Disconnects Safety disconnects cut power to motor for servicing of unit. A factory mounted and wired disconnect is an option for UBCA units with the UL 762 designation. The disconnect may either be interior with an external weather-proof junction box (all units), or external (units up to 2 hp only). Wiring is completed from the motor to the exterior box. Factory mounted and wired interior disconnect switches are standard for all UDCA models. Safety Disconnects Safety disconnects cut power to motor for servicing of unit. A disconnect switch is an accessory available on UBCA units used for general ventilation, and is shipped loose for field installation. An optional wiring harness is available to connect the motor to the switch at the internal junction box. Factory mounted and wired internal disconnect switches are standard for all UDCA models. Backdraft Dampers Gravity or motor operated backdraft dampers are available. They are aluminum construction and designed for installation in prefabricated roof curbs. Birdguards Wire birdguards are available to prevent entry of birds or other potentially damaging objects. Grease Collector Speed Controller (UDCA models only) Grease pans collect grease drained from the fan. An integral baffle contains the grease while allowing water to flow from the pan. The grease collector should be attached to the curb below the standard drain. Solid state speed controller provides capability to change performance and speed ranging from 50% to 100% of fan capacity. This permits adjustment for fine tuning and balancing the ventilation system (see performance tables). General Options and Accessories Hinged Base Kits Hinged bases are specifically designed to provide easy access for cleaning and servicing the lower parts of UBCA and UDCA units. Roof Handle Aluminum handle facilitates removal of the roof. A roof handle is standard for units with the UL762 designation. Special Motors Two-speed, totally enclosed, energy efficient and explosion-proof motors for hazardous locations may be available for many models. Motor requirements may affect UL listings. Protective Coatings Fan units are not recommended for exhausting air of a corrosive nature. However, special protective coatings are available where units may be exposed to corrosive exterior conditions. Parts requiring painting are processed through the American Coolair five-stage pretreatment system prior to the application of any coatings to insure maximum finish adhesion. These parts use a thermosetting epoxy powder paint with an average thickness of 3 mils and baked at 400° F to a smooth, hard continuous finish. Consult your ILG Industries representative for available coatings. 23 ILG UBCA Specification Checklist UDCA Specification Checklist • • Units provide grease-laden vapor extraction and general exhaust with vertical discharge for low, medium and high air volumes, especially in commercial and institutional kitchens. • Centrifugal design has advantages of compact, attractive appearance, quiet operation and performance against higher static pressures. • Variable pitch belt drive allows for speed adjustment. • Adjustable hinged motor bracket facilitates maintenance of belt tension. • Weatherproof heavy duty aluminum housing and motor compartment cover resist corrosion, maintaining appearance. • Deep-spun, overlapping, one-piece venturi/bottom outer housing minimizes noise, reduces air turbulence and improves efficiency. • Aluminum centrifugal wheel is quiet, non-overloading, backward-inclined design and is computer balanced. • Standard open drip-proof motor is out of the airstream for protection. • The motor is mounted with the shaft up for convenient access to the variable pitch cast iron motor pulley. • The motor compartment is cooled by a forced air ventilation system, extending motor life. • Units have the UL Label for the removal of greaseladen vapors and fumes (UL 762), for general ventilation (UL 705), or for high temperature operation (UL793). • AMCA Seal assures certified rating of air and sound performance. • Heavy duty pillow-block bearings are self-aligning and relubricable. Units provide grease-laden vapor extraction and general exhaust with vertical discharge for low and medium air volumes, especially in commercial and institutional kitchens. • Centrifugal design has advantages of compact, attractive appearance, quiet operation and performance against higher static pressures. • Direct-drive has advantages of minimal maintenance and operating costs. • Safety disconnect switch allows power to be cut off for servicing of unit. • Weatherproof heavy duty aluminum housing and motor compartment cover resist corrosion, maintaining appearance. • Deep-spun, overlapping, one-piece venturi/bottom outer housing minimizes noise, reduces air turbulence and improves efficiency. • Aluminum centrifugal wheel is quiet, non-overloading, backward-inclined design and is computer balanced. • Standard open motor is out of the airstream for protection. • The motor compartment is cooled by a forced air ventilation system, extending motor life. • Units have the UL Label for the removal of greaseladen vapors and fumes (UL 762). • AMCA Seal assures certified rating of air and sound performance. Limited Warranty In the sale of its products, American Coolair Corporation agrees to correct, by repairs or replacement, any defects in workmanship or material that may develop under proper and normal use during the period of one year from the date of shipment from the factory. Any product or part proving, upon American Coolair's examination, to be defective during limited warranty period will be repaired or replaced, at American Coolair's option, f.o.b. factory, without charge. Deterioration or wear caused by chemicals, abrasive action or excessive heat shall not constitute defects. Motors are guaranteed only to the extent of the manufacturer’s warranty. American Coolair's limited warranty does not apply to any of its products or parts that have been subject to accidental damage, misuse by the user, unauthorized alterations, improper installation or electrical wiring, or lack of proper lubrication or other service requirements as established by American Coolair. Repairs or replacements provided under the above terms shall constitute fulfillment of all American Coolair's obligations with respect to limited warranty. THE LIMITED WARRANTY STATED HEREIN IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS, STATUTORY OR IMPLIED, INCLUDING WITHOUT LIMITATION THAT OF MERCHANTABILITY AND FITNESS. NO LIABILITY FOR REINSTALLATION COST OR FOR ANY SPECIAL, INDIRECT OR CONSEQUENTIAL DAMAGES OF ANY NATURE IS ASSUMED OR SHALL BE IMPOSED UPON AMERICAN COOLAIR. REPRESENTED BY: AMERICAN COOLAIR CORPORATION JACKSONVILLE, FLORIDA 32203-2300 ~ P.O. BOX 2300 ~ (904) 389 3646 ~ FAX (904) 387 3449 ~ E-MAIL – [email protected] ~ WEBSITE - coolair.com VANE AXIAL FANS ~ TUBE AXIAL FANS ~ PROPELLER FANS ~ POWER ROOF VENTILATORS ~ CENTRIFUGAL VENTILATORS MEMBER OF AMCA ILG Form No. 710-15-5 (March, 2016)
© Copyright 2026 Paperzz